110-79 Ordinance - , 67 'I." ::! \ RECDRD/~ OF: r"OAIJINANEE5;; , , " NattonalGraph1ca Corp., ColB., O. ~ Form No. ZaQ6<.A Ordinance No.__1L~_:_1'-m ~AN 2 1 1980 p assed-------,-_________________________________~_c____._19_..___ .. AN ORDINANCE DELINEATING PROPER IN- STALLATION OF HEATING STOVES, FREE- I STANDING FIREPLACES, AND PREFABR 1- CATED FIREPLACES, AND REQUIRING A PERMIT AND INSPECTION OF SAME. WHEREAS, the Dublin Village Council is cognizant that owners of existing homes and homes under construction are i nsta II i ng heat- ing stoves, freestanding fireplaces and prefabricated fireplaces to offset increasing home heating costs and/or for decorative/ aesthetic reasons, and WHEREAS, the Vii lage of Dublin currently has no regulations deal- ing with the proper insta"ation of heating stoves, freestanding fireplaces and prefabricated fireplaces and inspection thereof, and WHEREAS, the Dublin Village Council believes that there is a strong and present need for such proper regulations and inspect- Ions; NOW, THEREFORE, BE IT ORDAINED by the Council of the Village of Dub I in, State of Ohio, ~ of the elected members concurring: I SECTION I . That the Directives marked as Exhibit "A" and Exhibit "B" attached hereto, and thereby made a part of this Ordinance, , sha II be implemented and enforced by the Building I nspector under the supervision of the Village Engineer. SECTION 2. That the Building Inspector sha II inspect all free- standing fireplaces, heating stoves and prefabricated fireplaces in newly constructed residences in the Village during the final or occupancy inspect ion. No separate permit or fee is required. SECTION 3. That a Permit must be applied for and received before a freestanding fireplace, heating stove or prefabricated fire- place may be installed in any currently existing residence in the V i II age and an inspection of same shall be performed by the Building Inspector. The Building Inspector sha II dev i se the pro- per application and permit forms. Said Permit shall involve a Fifteen Dollar ($15.00) fee payable upon application. SECTION 4. That this Ordinance shall take effect and be in force from and after the earliest period allowed by law. Passed this ~ day of fAN.."t~ , 19'D. I eL~J ~-<_ Mayor - Pres i d i ng Off i cer Py..i~9"" Pya T8111118..e ATTEST: Ref-. W-.4~ 7 Clerk - TI 64."Y8yJ ' 0+ C<>\A.~~, \ !m\;l"., ';':'f' iil ,""ii,"'''.'''''::: Ii : .,. .,.,: ." ..., ~. -.... j , t' , ~t'~~ C~ INCORPORATED Dublin, Ohio 43017 EXHIBIT "A" DIRECTIVE ON FREESTANDING FIREPLACES I AND HEATING STOVES A. Freestanding fireplaces and heating stoves shall be in- stalled in compliance with the manufacturer's i nstruct- ions and with the conditions of the appliance listing by Underwriters Laboratory (UL) or other recognized testing laboratory. B. Floor protection shall extend at least 12" beyond the sides and rear and 20" beyend the front. C. Floor protection shall be of approved material equivalent to the following according to the length of the stove legs or the height of the fireplace above the floor. I . 6" to 18": 24 gauge sheet metal laid over a 1/4" sheet of asbestos millboard. 2. 6" or less: 2" to 4" of hollow masonry laid I to provide air circulation a~red with a sheet of 24 gauge sheet metal. D. Provide 24 gauge sheet metal thimble for smoke pipe where required to pass through combustible wall construction. Thimble diameter must be three times the smoke pipe diam- eter. Horizontal section of smoke pipe shall rise 1/4" per foot of pipe. E. Smoke pipe s ha II have the clearances according to the type of protection provided. " a ~ :r: I-U <z - I m z 0 - I- U L&J 5 0::: Q. L&J 0::: Q. L&J - Q. Q. 0 0::: L&J Q. ~ 0 :r: :::E l- V) - 3 I V) N <( - 0 I ... :r: L&J l- I- l- LL. - 0 :::E 0::: 0::: L&J L&J Q. I- L&J L&J :::E U < z I - < 0 0::: < L&J L&J :r: ...J I- U V) 0 L&J L&J :::E U - :::l CO I- 0 ...J L&J < L&J 0::: - L&J L&JO::: 0::: L&J >L&J :r: :r: -l- I- I- 1-< U:::E V) V) L&J ...J ...J I- < < 0 :::l :::l 0::: 0 0 Q. L&J L&J ~ ~ C:t:J < ~ ~ - 1 . . , . , " -3- F. Heating stoves shall be of the following types: I . A radiant stove is one with a single layer of metal enclosing the fire. 2. A circulating stove is one with a sec- I ond meta I jacket enclosing a space for heating and circulating air. 3. A supplemental^heating device is one such as the Add-A-Furnace. G. The clearances indicated herein apply except where the listing of an appliance specifies a greater clearance, in which case the listed clearance will contro I . H. Asbestos millboard referred to herein is a different material from asbestos cement board and asbestos cement- board will not be approved. I . 8" masonry walls or other non-combustible construction require no clearance except for proper operation of the appl iance. I J. Freestanding fireplaces and heating stoves shall be i n- stalled with the clearances from the unprotected or pro- tected combustible materials as herein indicated. I . All clearances should be measured from the outer surface of the appliance to the combustible material disregarding any intervening protection applied to the combustible material. 2. All freestanding fireplaces and heating stoves sha II have 48" clearance in front of app I i ance. . 3. Protective coverings shall extend over all areas of wa II and ceiling to the minimum clearance allowed for an unpro- tected wall, that is 36" for appliance and 18" for stove pipe. a ':" r -4- 4. Protection required to reduce clear- ances sha II be i nsta II ed as indicated below: I A 1 . . Fireplace or rotective Heating stove Material . "A" & "C" EQUALS THE REQUIRED CLEARANCE WITH -NO PROTECTION. I "8" EQUALS THE REDUCED CLEARANCE PERMITTED WITH PROPER PRO- TECTION. , 'K. Where stove pJ,pe is connected to flue installed through ceiling the standard ceiling plate or box fittings fur- nished by manufacturer and bearing the underwriters la- bel (Ul) will be accepted. These fittings shall be in- stalled according to manufacturers instructions and need not have clearance from ceiling as indicated in . Paragraph E above. Flue sha II have wall clearance as required. . , r . , ./ : , , -5- L. The following clearance shall be maintained according to the type of protection provided. RADIANT STOVE C fRCUlAT I NG STOVE OR STOVE PIPE SUPPLEMENTAL HEAT DEVICE I ABOVE SIDES ABOVE SIDES AND AND TYPE OF PROTECTION REAR REAR NONE 36" 36" 36" IB" IB" i" asbestos millboard spaced out I" with non combustible SDacers. 30" IB" 30" 9" 12" 2B ga. sheet metal on i" asbestos millboard. No spacers. 24" IB" 24" 9" 12" 2B ga. sheet metal spaced out I" with non-combustible spacers. IB" 12" IB" 6" 9" ~B ga. sheet metal on I/B" ~sbestos millboard spaced put I" with non-combustible spacers. IB" 12" IB" 6" 9" I ~" asbestos millboard on I" mineral fiber bats re- inforced with wire or eouivalent. IB" 12" 18" 6" ~" 22 9a. sheet metal on I" mineral fiber bats rein- forced with wire or equiv- alent. 18" 12" 18" 3" 3" i" asbestos millboard 36" 36" 36" IB" IB" i" cellular asbestos 36" 36" 36" IB" IB" NOTE: Any of the above listed types of protection may be covered with an) type non-combustible decorative material such as brick, tile, "Z- .. .. . , , ' I .'... . . .- -6- brick", slate, marble, etc. Decorative material shall be installed with non-combustible fasteners or adhesives. The use of these non- combustible decorative materials shall not reduce the required clearances from combustible materials as listed on before-mentioned page. I M. All fireplaces and heating stoves shall have an approved chimney connection, consisting of the smoke pipe and either an approved prefabricated chimney or a thimble mortared into an acceptable masonry chimney. N. Provide a spark arresting screen and raincap on top of the chimney. O. Only one fireplace or heating stove shall be 'vented into one flue. Only one fuel sha II be connected to a flue. P. The smoke pipe shall not reduce in size from the smoke collar of the stove to the chimney. Q. Do not connect stove vent into an existing masonry chimney unless the chimney is inspected and approved. I R. A II flues sha II have a cleanout below the point of entry of the smoke pipe. In masonry chimneys the distance shall be twelve (12) inches. S. Heat i ng stoves inserted into existing masonry fireplaces cannot be approved unless a positive smoke pipe connection can be made into the exis~ing ~Iue in compliance with ac- cepted engineering practive as per N.F.P.A. NO. 211 "Stand- ard for Chimneys, Fireplaces, and Venting Systems." T. Permits for freestanding fireplaces and heating stoves are issued only to residing homeowners, licensed heating con- tractors, general contractor or builder to whom a building permit is issued or a home improvement contractor. u. Check with your insurance company. Some companies do not wish to insure homes heated by wood, because of the increased fire hazard or may require an inspection by an insurance com- pany representative. ~. .. _u._.' . ...'.~ , . ' , , . . . . ~~91~. a INCORPORATED Dublin, Ohio 43017 EXHIBIT "B" DIRECTIVE ON PREFABRICATED FIREPLACES I A. Metal prefabricated factory built fireplaces either free standing or constructed exposed against a wall and installed with a metal flue will be inspected by the building inspector. B. Metal prefabricated factory built fireplaces i n st a I led wit h a metal flue and enclosed into the building with studding shall be inspected by both structural and heating inspectors. The structural inspector sha II inspect the studding framing ad building details. No wood framing shall be within two inches of the back of the fireplace. C. When the bottom of the prefabricated firebox is at a higher elevation than the hearth, the 20" minimum hearth width shall be measured from this edge of the metal fireplace unit. D. The fireplace recess surfaces shall be fire-resistive plaster, masonry or i" fire code gypsum board. The recess covering shall be carried up to the elevation of the connection of the metal flue to the fireplace firebox. Above this elevation the metal flue sha II have the clearance required with its U. l. rat in g, or the building codes. I E. Maximum height of unsupported metal flue or boxed in frame chimney covering metal flue shall be six (6) feet above the supporting roof. Boxed in frame chimneys or metal flues higher that six (6) feet shall be braced as approved by the building inspector. F. Boxed in frame ch.imney covering metal flue shall be provided with a water tight metal cap and necessary flashing collar at metal flue. The metal cap shall be installed to provide drain- age, and slope to the edges of the boxed in frame chimney. G. Gas and electric only fireplaces shall have an approved metal plate so stating, attached to rear of fireplace. H. Fireplace hearth shall be of size indicated in National Fire Protection Association (N.F.P.A.) No. 211, and any subsequent a . . .'"' . . , , . , , . . . . . -2- amendments thereto, but can be type of noncombustible material furnished with prefabricated fireplace. Hearth and prefabricated fireplace may be placed on combustible floor construction as re- commended by manufacturer when U.l. approved for such installation, 20" wide minimu~. I . Prefabricated fireplaces shall have opening trimmed (Check N.F.P.A. NO; 211). No combustible material within 6" of the fireplace open- . ,ng. I J. A II prefabricated fireplace installations require a permit and inspect ions. Prefabricated fireplace enclosed into the building is included in the building permit unless otherwise indicated in the permit fee schedule. K. Permits for prefabricated fireplaces are issued only to residing homeowners, licensed heating contractors, general contractor or builder to whom building permit was issued or person holding a home improvement contractors license. I . a . . . .. '0 . :' , NATIONAL FIRE PROTECTION ASSOCIATION INTERNATIONAL "Moving Mankind Toward Safety From Fire" RICHARD E. STEVENS ASSISTANT VICE PRESIDENT FOR STANDARDS I December 19, 1979 Mr. Dave Price Building Inspector Village of Dublin Post Office Box 206 Dublin, Ohio 43017 Dear Mr. Price: Thank you very much for contacting us about reference to NFPA 211 and reproducing sections of NFPA 211 for your rule-making process. Please consider this letter asNFPA's approval for you to do that. The only thing that we request is that with any material reproduced from NFPA 211 you include the following copyright statement: "Extracted by permission from NFPA 211, Standard for Chimneys, Fireplaces and Vents, Copyright@1977, National Fire Protection Association, Boston, MA." Very tr~l ours, .../ I Ai? Richard E. Stevens RES/ cp EXECUTIVE OFFICE: 470 ATLANTIC AVENUE, BOSTON. MASSACHUSETTS, U,S.A. 02210 · TELEPHONE AREA CODE (617) 482-8755 · TELEX 94-0720 The non-prof~ 1echnicol and educotional orgonizotion: To promo1e the science and improve the methods of fire protection and prevention; 10 oblein and circulote information on these subjects and 10 secure the co-operotion of its members and the public in eslablishing proper sofeguords against loss of life and properly by fire,