Loading...
08200028 Permit FileCITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 8/26/08 Parcel Number . . . . . 273-000885 Property Address ... 5700 SHZER-RINGS RD FR DUBLIN OH 43016 Subdivision Name . . . Legal Description ... 5700 SHIER-RINGS RD ENTRY 2542 11.565 AC .7694 AC HI-WAY EASE Property Zoning . . . . RESTRICTED INDUSTRIAL Owner . . . . . . . . . BATES PROPERTY MANAGEMENT LTD Contractor . . . . . . DUBLIN BUILDING SYSTEMS 614 889-1445 Application number .. 08-00200028 000 000 Description of Work .. COM BUILDING ADDITION Construction type . . . 2B - PROTECTED/NONCOMB Occupancy type . . . . BUSINESS Flood Zone . . . . . . Special conditions . . Stanley Steemer 5700 Shier Rings Road Dublin, OH 43016 Approved . . . . . . . Officia VOID UNLESS SIGNED BY LDING OFFICIAL This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. Inspection Type(s): ZONING INSPECTION FORM Zoning/Landscape ? Land Use and Long Range Planning Commercial Code Enforcement Residential ? - ° Sign ? CITY OF DUBLIN 5800 Shier-Rings Road; Dublin OH 43016 ;0J; C,: Other ? Telephone/TDD 614-410-4600 Dublin Planning Fax 614-410-4747 Dublin Inspection Line 614-410-4680 } -, , , ? ??' ?"' .t#• ? .. , . ' ermi . , x r = ? ro.ect Name. . ? t,.?. . t ''?? C? ;; C::? ?: ,.. P Pro'ect Address: 0 c' "V Contact Person: t Phone: t C on ac .+" YES NO 1) Approved Landscape Plan & ROA YES NO -6) Sign installed as approved ! YES NO 2) Plans, Checklist & Permit on Site YES NO ,..,7)+Parking spaces, number & striped YES NO Lighting installed per plan r YES N0 8) Handicap spaces properly signed YES NO 4) Landscape installed per plan YES NO ,.11' Parking islands 7 foot minimum YES NO ,.,-S1 Mechanicals screened per code YES NO 10) 1G4eet residential appearance code Zoning Approved?l r Zoning Conditionally Approved (See Comments) ? Zoning Disapproved (See Comments) ? r ' ...._ ..,.,... ... -. . _ , Date of Ins ection Ins ected *?-,-•=? - ? COMMENTS Zoning Inspection Form PLA-120 Date 08/12/04 v < y O 3 n 0 ? ? M n D r z cn M rn n 0 Z CO) ? Z O n ,n O h ? W 3 ? O - = Q (D _ .. ? ? N ? ? fl. O ty V y O ? . ? ? y O 'C V) ? 3 ? !D 7 M rS' to ?D y .. X ^ O ? L 0) a ? ?. ' ?v o c ? cr a? w? o 0 =r 0 ? w 0 ? v? CITY OF Di1BLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Fax: (614) 761-6566 • Inspection Line: (614) 410-4680 DO NOT REMOVE THIS SHEET FROM SITE NOTICE OF INSPECTION Inspection Type Ujr?? :?fay A?C Application # Bl2q "ig Date The undersigned inspectors checked your property at ?W? VAX, AW65 AO for compliance with Building Code. Any violations listed below must be corrected within days. ?. ? APPROVED ? ( ISAPPROVED By ? CONDITIONAL INSPECTION REPORT - 08-075.1-1132a Jack D. Walters & Associates, Inc. Architects & Engineers P.O. Box 855 Dublin, Oh 43017 Tel: (614) 889-2516 Fax: (614) 889-5596 incoming@jdwae.com PROJECT: Stanley Steemer 5700 Shier-Rings Road Dublin, Ohio 43017 INSPECTOR: Michael Newport REVIEWED BY: Karl Walters REPORT NO.: 08-075.1-162a WEATHER CONDITIONS: INSPECTION REGIUESTED BY: PERMIT #: INSPECTION DATE: ARRIVAL: DEPARTURE: REPORT DATE: 08-00200028 August 18, 2008 1:30 P.M. 2:00 P.M. August 18, 2008 Sunny, 85 degrees F Ken Reese, Dublin Building Systems REFERENCE DESIGN DOCUMENTS Latest drawing set on site Special inspection, in accordance with the requirements of Section 17 of the 2008 Ohio Building Code, is the process of verifying that the field installation of the described component is in general compliance with the approved construction documents. A"verified" component/installation in no way indicates design approval and/or conformance with the Building Code. Item designations are referenced from Table 1704.3; "REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION", 2008 Ohio Building Code, page 306. ITEM DESIGNATION: 2. Inspection of High-strength Bolting a. Bearing-type connections DESCRIPTION: All structural steel bolted connections INSPECTION FREQUENCY: Periodic VERIFIED: Yes REMARKS: None `??tIi1i111,,1 ?? 0 F .?? : ?Q' • •... ,y? , DISCREPANCIES: None . Karl ?'• O ; - l. - = -D Wolters ; o ?•. E-60652 : ?s' • ?IV1? ••'.C ? : , , ? .``. ? ???liiilitt 08I18i2098 12:07 7403455020 GUTRIDt;E PLUMBIPJG PAGE 01 9- a GUTRIDGE PLUMBING INC. 88 SOUTH 2ND STREET NEWARK, OHIO 43055 P: 740-349-9411 F: 740-345-6020 FAX CQVER LETTER DATE: ? COMPANY: i, TO: 6j::?J% SUBdECT: SAn / TOTAL NUN1BER OF PAGES: a COMMENTS: .-, .11 , IF YOU HAVE A PRO$.i,F.M AECEI'VTNG TOTAL NUMBER OF PAGES, OR FIAVE A QUESTION PLEASE CALT, 740-349-9411, THANK YOU, WAYbE GUTRIDGE GUxRIDGE PLUMBING INC. PRESIDENT i 08/ 18f 20FJ8 12: 0r 7493455020 GUTRIDGE PLUNIBIPJG c`2oOp 2 B' PAGE 02 KELLEY & ,A,.SSOCIATES ARCHITEGTS- PLA,.NNERS 51 N. 4r" STREET NEWARK.OHIO 43055 Ausust l g, 2008 DuUlin t3uilding Departme»t Dublin, Uhio 43017 ATTN: Scth RC: Stanley Steemez SSQQ Stanicy Steemer ('arkway Duhlin, Uhm 43017 Tlte gas pipin? tn cuiit heater #; has bcen deletecl. C'orcl i n I ly. t'atrirl: K?Ilc?v .'lt'Chitc?[ CITY OF DUBLtN Division of Building Stanclards COMMERCIAL BUILDING PERMIT APPLICATION 5800 Sfier Rings Road DuWin, Ohio 43016 Telephone: 614-4104670 atspection une: 614-41o-mo ' Facsimiie: 614-761-6566 PROJECT iNFORMATION ; aarm: J5760 5N??rz-l2+aas ?? s 12. 544 rojectName sr,a?.Ji,?Y Sr?EwtE? ? QF?? ? 6matett Cost of Consfivc6on UOO Parcel Number '7 - 00 O S PROPERTY OWNER INFORMATlON Propbfty Owner Narrie (Con4d Petm if awned by a Cvrpora6on)?1 ?it?Ol?c1 l.l atry NameAATE3 ?R?E2T`/ N??W9G,E??.TAddress _ 5500 ?T,a?JL&? S'T?icM P L1 0tv u 'D? ? a sta?a? ??, zQ-- ?F3o?t? - " Fwc - 7 / - 7 E-Mai . ? TENANT INFORMATiON (ff Applicable) W;Nam AIA?.I 8eo?,1Hl anY NatneS'Q? -cj2jkVy Eic Address_ 5 70a SrtIIC e- (Z+ ?.?, - D?BLiiJ State??1?iD ?p 4301(n r°O ? - 7 7 E t 6,c co?.c RCHITECTSj?, OR OTHER DES)GiV pROFESSIONAL INFORMATION Design Professional Name V I G.Tb ??? Oha Reg/Cert Number Namek08Lws/ Bryi ey.fG S?,•Lr?c pddress r? ?IIi'4?? 1Qsa ' _?c18L?iJ stabe ?o Tp 4301 !a Leie e - F - - 5 E-t&a 44.4 GENERAL CONTRACTOR INFORMATION (Must be a City of Dubtin Registered Contractor) tact Narne,.CAiPrs>alcrt PJ.j1? Uuwm RegistraGon # 45-08 anyN?ne.1,1,8[.?,? ,?WCOi..? SriSlrFMS Adc?ess ' 'Li?J S4te TP ?3o/C? e.1 hot?e ? - F E-Mai AFFIDAVIT OF UWNER AUTHORIZATION FOR REPRESENTATION Note: This person wili be contacted wifh all official correspondence. AII signattq'es must be ORIGINAL ei's R?46ve5?i?ToP?IlZ P. ?4/nJ Relationship tD Pcoiect G6?4?2a /.,..>>? ToR anyName Mc28Ci.? ???? posiSa4CnUdr? ,??Telephone_QK-S3% l?S I. &aA.J SZ oLJA) &as$ Prin9, the oiimer and aPPicant, herebY to ad as my representative and agent in al matters petlaining to ihe prawssing and vfptoval of Ihis appGca6on inducing mdk*9 the WojeeL a?d 1 agree tio be bound by aB representaSons and agmenetits made by Oe designated agent ignature of Pr+opedy Owne? /_/9 ? Date: ?S ?oO ? the Owner orthe Ownees RepteseMaGve, have read and understand ihe contents of aA 3 pages of ft appGcation. The infama6on oontained in this APPkation, attached exbbits and odw infamation submitted is complete in ap tesp 6ue and to lihe best of my knowledge and beGef. 1ignamre of owner's R enha6ve: ? p?r/y,4GX, Date: /6 Z° eu ilding Standards Division Use OMy Date Received Building Standards (9? -' 0009 Gcation Number I 1 COl/MERGAlBUILDINGPERMRMPUf:J4710N P"etef7 PiPAS5VLDGlF0FtMS10OMNAPP.W82 Faud8l)-201 Dale:03f16A0', ?,:? QUBLIN ? ' CITY" OF DUBLIN Division of Building Standards COMMERCIAL BUILDING PERMIT APPLICATION Project Name___ ?T??.I(.,E? ST'cCWt Permit Number PROJECT INFORMATION ' .. . . NOTE: The fo0owing information is to be completed by the Design Professional, registerEd in the State of Ohio, who was primarity responsible for the preparation of the construction documents. `: -Scope of Project ??rJ J F? L.Tc.9t2.1 iV'G ?T7r? i T U? TYPE OF WORK (Ctieck a11 that apply) A. New Structtare 8. Additien f Fire Wall Yes No C. Alteration Ar#ide 34 Yes No D. Change of Use _ Entire Structure Partial E. Change of Occupan Entire Struc#ure Partial Previous Use(s) pE???t7F- -ru?! ti?Use Group(s)_ ?? F• ? AAIALYSIS OF NEW STRUC7"URE, ADD/T10N, AND/OR AREA TO BE ALTLRED A. Occupancy Description-A4A.b1 oF/4c,X2ilZI,,jCn Use Group(s)_ E- f B. Mixed Use: Yes Non-separated ? Separated [l No? C. Type of construction ?j D. Fire resisUve construction Fire Test Design Numbers Exterior WaUs n hr. Fire WaHs 61A_ hr. Floor/Ceiling n_ hF. ColumnsBearing Wal! _ hr. Exit Endosures KNYa, - hr. Shafts A hr, Corridors _ gohr. Tenant Separation _ QR hr. E. Ftoor Area/Fioor Occupant Load/Floor Egress Capacity/F1oor Number of Exits Basement lst 2nd - 3fd 4th 8 above F. Allornrable maximum floor area (first floor footprint) JIJ L tM i Y'6 tj Does the above indude street frontage increase? Yes No Does the above indude increase for sprinklers? YesB No? G. Number of stOries above grade I Height 2 I- I OY-z " Basement Yes[::] NoCRI CLIMMERCIAL BWLDING PERMR APPLICATIOtd Page 2 af 3 P.WASS18Lp ,(`1Fp(tMS1COMMAPP.WB2 Fam# BlD-201 pate:1W19199 ,, . ?l 1 Y vr .u u13L1N ' Division of Building Standards COMMERCIAL BUILDING PERMIT APPLICATION H. Horizontal exits Yes 1 No . Limited sprinkler system Yes J No . Full automatic sprinkler system Yes K St d i t No . an p pe sys em Yes L ? No . Smoke controlJRemoval sys#em Yes No Ne, M. Unlimited area building Yes a l ' No N. Manual fire al rm Yes No 0. Auto fire alamn Yes No P. Handicap accessibie route (exterior & interior) Yes No : Q. Structural Loads: provide table of design loads with constructio u, n d ocuments EXISTIIlIG STIZI/CTURE ANALYSIS (Compiete for all aiteration or addi6on projects) A. Ocxupancy Descfiption Ai.A F ATo se Group(s)- ALE:!L B. Mixed' Use: Yes ? Non-separated ? Separated Q No C. Type of construction ? D. Floor Area/Floor Occupant Load/Floor Egress Capacity/Floor Number of Exits Basement I st So ?}-ao . ?o ? - I,Soo ? 2nd - 3rd 4th & above E. Allowable maximum floor area (first floor footprint) u"Ljr,4 lT1aD Does the above inciude street frontage increase? Does the above indude increasef l i l ? _ Yes? No Rq or spr n c ers Yes No F. TJumber of stories above rade_ I B ildi H i ht 2t ' " - u ng e g - I p Bas emerrt Yes[[ ] Noo G. Horizontal exits Yes No H. Limited sprinkler system Yes No i. FuN automatic sprinkler system Yes No J. Standpipe system Yes No K. Smoke controVRemovai system Yes No L. Uniimited area building Yes No M. Manuai fire alarm Yes No N. Auto fire alarm Yes No 0. Handicap accessible route (exterior & interior) Yes No P. Structural Loads: provide table of design loads with construcdon d ocuments . I. _ V 1 C.T TD. I F l. A K1 the Design Professionai, have read and understand the contents ofthis apptication. The information contained in this application, attached exhibits and other infamation submitted, is-complete and in alf respects true and correct to the best of my knowledge and belief. Signature of Design Professional:_ Date: ? o ? COMMERCIAL SUILDING PERMIT APPLICATIDN Pape 3 of 3 PiPASSIBLDC,tiFORMSICOMMAPP.W62 FoOr# BLQ201 Date:1011U99 CITY OF DUBLIN Division of Building Standards * 5800 Shier Rings Road * Dublin, Ohio 43016 Inspection Requests: (614)410-4680 Telephone: (614)410-4670 SUBCONTRACTOR DISCLOSURE Application Number: 08-200028 Project Address: 5700 SHIER-RINGS RD General Contractor: DUBLIN BUILDING SYSTEMS Telephone: (614) 889-1445 All registrations must be current through the issuance of a Certificate of Occupancy, including insurance and all applicable State Certifica tions. TYPE NAME DUBLIN REG. # (fequired) EXCAVATION ? ?it? _? c v U- ,• ? 0GJ - 4O?A0 ELECTRIC - HVAC Zg-o? PLUMBING . I` r M t ?i 0 2- - 0 CONCRETE LANDSCAPING ? o? A s? v l?3 - 1?1 SANITARY SEWER The General Contractor is required to provide a completed copy of the above information to the Building Official at the time of the Certificate of Occupancy inspection. ? 46 CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 APPLICATION FOR HVAC PERMIT Date ` `? ? Application No. ,,66 # 08604., 6 b -"'UWZL. Job Address 577 04) S? 10t A 04 S 20 Parcel No. I-? ??855 TnY?-1 i, i`j LYt_' Lot No. _ Owner Name M" rA4?V9rj /N? ?r-?%,1 &-ruT L-TQ Telephone Contractor Name Contractor Address Residential: C u 57O-r" fh GL m pr Sq. Ft. $591OUnimum plus $20:9?'ftSr each additionalSW§q. Ft. or (Replacement units, minimum fee) Telephone 6 14-3?5^27p0 2 -z, Dublin Registration No. log~ ?6 t-06/r - ? ? / Alteration: ?inimutn plus $?19?'.OUfor eac.h additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. 3% State of Ohio Surchazge (commercial only) Total $ JOB DESCRIPTION iltj'5 U/f e(! ---- <a --- This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of Dublin and all the laws of the State regulating construction, installation, repair and alteratior}„ and may be revoked at any time upon violation of any provisions of said laws. , /' ?? Signature of licensed contractor Division of Building Standards Mary Moreland From: Jennifer Brock [JBrock@dublin.oh.us] Sent: Tuesday, June 03, 2008 9:14 AM To: Mary Moreland Subject: RE: SQ FT ADJUSTMENT I didn't realize it was an addition. You are correct, the fee is $103. Page 1 of 1 »> "Mary Moreland" <MMoreland@customairco.com> 6/3/2008 9:12 AM »> Thank you, but I just want to verify. This is an addition not an alteration so should it be $103 for the permit? From: ]ennifer Brock [mailto:JBrock@dublin.oh.us] Sent: Tuesday, June 03, 2008 9:09 AM To: Mary Moreland SubjeCt: RE: SQ FT ADJUSTMENT The plan reviewer has confirmed the area so we will base the fee on 1,500 square feet. Your fee will be $92.70. Please attach a copy of this e-mail so the individual processing the permit can verify fee adjustment. Jennifer »> "Mary Moreland" <MMoreland@customairco.com> 6/3/2008 8:33 AM »> Approximately 1500 sq ft. Mary From: Jennifer Brock [mailto:JBrock@dublin.oh.us] Sent: Tuesday, June 03, 2008 8:02 AM To: Mary Moreland Subject: Re: SQ FT ADJUSTMENT Mary, What is the total area you are working in? »> "Mary Moreland" <MMoreland@customairco.com> 6/2/2008 10:26 AM »> Sending This PDF to see about getting a sq ft adjustment? Application # 08-200028 -12,554 sq ft. We are installing (2) gas unit heaters and (1) wall fan as shown. Please review and let me know the cost associated for our HVAC permit. Thanks, Mary Moreland Custom Air 935 Claycraft Rd Gnhanna, OH 43230 Phone: 614-552-4822 Fax: 614-552-2837 Email: mmoreland@customnirco.com This e-mail transmission contains information that is confidential and may be privileged. It is intended only for the addressee(s) named above. If you receive this e-mail in error, please do not read, copy or disseminate it in any manner. If you are not the intended recipient, any disclosure, copying, distrlbution or use of the contents of this information is prohibited. Please reply to the message immediately by informing the sender that the message was misdirected. After replying, please erase it from your computer system. Your assistance in correcting this error is appreciated. ? i? i?nn4 ? CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number ..... 08-00200028 Date 6/09/08 Revision number . . . . . . . 2 Property Address ...... 5700 SHIER-RINGS RD Parcel Number: 273-000885 Alternate Address: Tenant nbr, name ...... STANLEY STEEMER Application type description COM BUILDING ADDITION ---------------------------------------------------------------------------- Application desc Sq Ft 12,554 ---------------------------------------------------------------------------- Property owner ....... BATES PROPERTY MANAGEMENT LTD Contractor . . . . . . . . . DUBLIN BUILDING SYSTEMS --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . 2B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS ---------------------------------------------------------------------------- Permit ...... COM HEATING, VENTILATING, A.C. Additional desc .. INSTALL (2) GAS HEAT &(1) FAN Permit Fee .... 100.00 Plan Check Fee .. .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/06/08 Qty Unit Charge Per Extension BASE FEE 70.00 .00 20.0000 THOU COM HVAC ALT .00 1.00 30.0000 THOU COM HVAC NEW/ADD 30.00 ---------------------------------------------------------------------------- Special Notes and Comments PHASED PLAN APPROVAL #1 AND CORRECTION REQUEST #1 FOR ALL EXCEPT FIRE SUPPRESSION SYSTEM, GAS PIPING, AND ELECTRICAL. BUILDING IS FULLY SUPPRESSED AND COMPLIES WITH THE REQUIREMENTS OF OBC SECTION 507. BUILDING IS FULLY SUPPRESSED AND COMPLIES WITH THE REQUIREMENTS OF OBC SECTION 507. APPLICATION #200029 FOR ADDITION FIRE SUPPRESSION IS APPROVED. APPROVAL FOR REAR BUILDING ADDITION AND RELATED SITE IMPROVEMENTS INCLUDING A PARKING LOT EXPANSION. SEE NOTES ON PLANS AND ALL ATTACHMENTS INCLUDING BOARD OF ZONING APPEALS BOARD ORDER #07-121V DATED 11/29/07. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 APPROVAL FOR REAR BUILDING ADDITION AND RELATED SITE This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. . CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number ..... 08-00200028 Date 6/09/08 Revision number . . . . . . . 2 ---------------------------------- ------------ ------------------------------ Special Notes and Comments IMPROVEMElVTS INCLUDING A PARKING LOT EXPANSION. SEE NOTES ON PLANS AND ALL ATTACHMENTS INCLUDING BOARD OF ZONING APPEALS BOARD ORDER #07-121V DATED 11/29/07. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600. *** IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE *** SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA ----------- ------------ ----------------------------------------------------- Other Fees . . . . . . . . . SURCHARGE FEE - HVAC --------------- 3.00 ------------ ------------------------------------------------- Fee summary Charged Paid Credited ---------- ---------- ---------- ---- Due ------ ----------------- Permit Fee Total 100.00 .00 .00 100.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 3.00 .00 .00 3.00 Grand Total 103.00 .00 .00 103.00 .? V. CITY OF DUBLIN ? Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 462-3865 (Franklin County) Application No. C) B. ?? a 8 Date 1-9-08 ? New ? Remodel ? Residential M Commercial APPLICATION FOR PLUMBING PERMIT The undersigned hereby applies for a permit to do plumbing and an inspection of same at the following location in accord with Chapter 4101:2-51 of the Ohio Administrative Code, and all regulations of the Franklin County Board of Health. Job Address 5/UU Shier Rings Road Subdivision/Project Name Stanley St Owner's Name Contractor's Name Gutridge Pluml Contractor's Address $$ South SeG? Does the sewer discharge into an indivKWI-ft-W How far distant from any dwelling, well or cistem What is the size of the main drain? 4" Of what material does the house drain consist? _ *INDICATE NAME OF CERTIFIED BACKFLOW the sewage €arrk? Of what Me PVC `?-??R Rod Gutrid arry 1 s INSTRUCTIONS Parcel No Lot No. Telephone Telephone 740-349-9411 Number gg-_3555 sanitarv sewer pipes consist? PVC Bob Milliman This form must be properly filled out and returned to the office of the City of Dublin at least four days prior to the date of the FIRST INSPECTION, accompanied by a fee calculated upon the following'basis: I RESIDENTIAL COMMERCIAL Application for permit & first fixture............................... $50.00 Application for permit & first fixture.............................. $60.00 Number of remaining fixtures X$10.00 =$ ? Number of remaining fixtures X$12.00 =$?l? Total Inspection Fee ..................................................... $ Total Inspection Fee ....................................................$ 'Ul Re-inspection fee (based upon di: aty, Air Admittance Valve ''Backflow Preventers Bath Tubs Bed Pan Washers Bidet Chemical Sinks Dental Cuspidors Dilution Sump Dish Washers Drinking Fountain Floor Drains Inspection and collected by the Franklin County Board of Health ONLY) $45.00 Qty. Garbage Disposal Hot Water Heater I nterceptor Kitchen Sink Laundry Trays Lavatories Mop Sinks Outside Faucets Roof Drains Rough-in Openings for Future Sewage Ejectors Showers Sterilizers Sump Pump Trap Primer Urinal Wash Fountain Washing Machine Water Closets Water Lines Water Storage Tank Other GRAND TOTAL H?TNVATF??INIg?F°?' "_^;??NT FEE $3 .00 Division of Building Standards - ? ? - CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . .... 08-00200028 Date 4/28/08 Revision number . . . . . . . 2 Property Address .. .... 5700 SHIER-RINGS RD Parcel Number: 273-000885 Alternate Address: Tenant nbr, name .. .... STANLEY STEEMER Application type desc ----------------- ription COM BUILDING ADDITION ---------------------------------------- ---------- --------- Application desc Sq Ft 12,554 --------------- ---------------------------------------- ---------- ----------- Property owner ... .... BATES PROPERTY MANAGEMENT LTD Contractor . . . . . . . . . DUBLIN BUILDING SYSTEMS --------------------- Str ucture Information 000 000 ------------ ---------- Construction Type . . . . . 2B - PROTECTED/NONCOMB Occupancy Type . . . -------------------------- . . . BUSINESS ---------------------------------------- ---------- Permit . . . . . . PLUMBING PERMIT Additional desc . . Permit Fee .... 84.00 Plan Check Fee .. .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/21/11 Qty Unit Charge Per Extension BASE FEE 60.00 2.00 12.0000 EA COM PLUMBING >1 FIXTURE ----------------------------- 24.00 ----------- ------------------------------------ Special Notes and Comments PHASED PLAN APPROVAL #1 AND CORRECTION REQUEST #1 FOR ALL EXCEPT FIRE SUPPRESSION SYSTEM, GAS PIPING, AND ELECTRICAL. BUILDING IS FULLY SUPPRESSED AND COMPLIES WITH THE REQUIREMENTS OF OBC SECTION 507. BUILDING IS FULLY SUPPRESSED AND COMPLIES WITH THE REQUIREMENTS OF OBC SECTION 507. APPLICATION #200029 FOR ADDITION FIRE SUPPRESSION IS APPROVED. APPROVAL FOR REAR BUILDING ADDITION AND RELATED SITE IMPROVEMENTS INCLUDING A PARKING LOT EXPANSION. SEE NOTES ON PLANS AND ALL ATTACHMENTS INCLUDING BOARD OF ZONING APPEALS BOARD ORDER #07-121V DATED 11/29/07. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 APPROVAL FOR REAR BUILDING ADDITION AND RELATED SITE IMPROVEMENTS INCLUDING A PARKING LOT EXPANSION. SEE NOTES This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. ? . CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number ..... 08-00200028 Date 4/28/08 Revision number . . . . . . . 2 ---------------------------------------------------------------------------- Special Notes and Comments ON PLANS AND ALL ATTACHMENTS INCLUDING BOARD OF ZONING APPEALS BOARD ORDER #07-121V DATED 11/29/07. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600. *** IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE *** SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 84.00 Plan Check Total .00 Grand Total 84.00 .00 .00 84.00 .00 .00 .00 .00 .00 84.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. 04/24/08 09:42 FAX 6144623851 COUNTY BOARD OF HEALTH C? 001 ?-?-.-? Franklin County Board af Heal#h PLUMBING R,????? TRANSMITTAL ? [Plan Revlew Fee Schedule Mwmber of Fixtures• Am+aunt Du+a: 1- 5 Fixtures $ 25.00 6 - 20 Fixtures $ 35.00 21 - 40 Fixtures $ 65.00 41 ar more Fixtures $100•00 Date: i , A 1- 11 MEW 6 RF-MODEL Job Name: Stanley Steamer Asidress: Cit,y: 5700 Shier Rin s Road , APPRTJVEU-SET OF PLAATS nublint ??rUST BE (?N 7't-aE JOf3 S1I'E. Signature: ? v W"PW.?-?••- ? '\'S TO TFf F I>1-•`,c 1:;tv1 Mt!5IBE RI:VlSF:ll t'klUlt 10 IIVSKC'T1ON. Plans submitted by: Gutridge Plumbing, Inc. Address: 88 South Second Street city & zip Newark 43055 RhonE #- (740) 349-9411 Paid By: . ? -- Check #: CopyTo: - - ? APPR4VEa //' ? 0 DISARRR ED er-kar: Insp Date: -- Franklin Caunty Roard of Heatth *^80 Fast Rroad 8treo# * Coiumbus, flH 43215 (614) 462-3160 phone # (614) 462-3851 iax n CITY OF DUBLIN Division of Building Standards o 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 APPLICATION FOR GAS PIPING PERMIT Date 1-9-08 Application No. 012). ALJW2kV Job Address 5 700 Shier Rings Road Parcel No. Subdivision Lot No. OwnerName Stanley Steamer Telephone ContractorName Gutridge Plumbing, InC. Telephone 740-149L9411 ContractorAddress 88 South Second Street, Newark 43055 Dublin Registration No. 0$-3555 ( ) Residential ()o Commercial O Alter Existing (IC) Addition to Building O Replace/Itepair Existing Type of Pipe to be Installed: ( ?Q Iron (} CSST O Other ?- Min. Pipe Size Required: in. Regulator Size BTU Max. Gas Appliances BTU/HR Range Water Heater Dryer Gas Logs Log Lighter Furnace(s) ? I-CD Other: Total JOB DESCRIPTION FEE $70.00 3°Io State of Ohio Surcharge (commercial only) a . jO Total $ This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the Ciiy of Dublin and all the laws of the State regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. Signature of licensed contractor or homeowner i*zm= 0 Division of Building Standards c??? W LA'1?. h CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number ..... 08-00200028 Date 4/28/08 Revision number . . . . . . . 2 Property Address ...... 5700 SHIER-RINGS RD Parcel Number: 273-000885 Alternate Address: Tenant nbr, name ...... STANLEY STEEMER Application type description COM BUILDING ADDITION ---------------------------------------------------------------------------- Application desc Sq Ft 12,554 ---------------------------------------------------------------------------- Property owner ....... BATES PROPERTY MANAGEMENT LTD Contractor . . . . . . . . . DITBLIN BUILDING SYSTEMS --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . 2B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS ---------------------------------------------------------------------------- Permit . . . . . . GAS PIPING PERMIT Additional desc . . Permit Fee .... 70.00 Plan Check Fee .. .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/25/08 Qty Unit Charge Per Extension BASE FEE 70.00 ---------------------------------------------------------------------------- Special Notes and Comments PHASED PLAN APPROVAL #1 AND CORRECTION REQUEST #1 FOR ALL EXCEPT FIRE SUPPRESSION SYSTEM, GAS PIPING, AND ELECTRICAL. BUILDING IS FULLY SUPPRESSED AND COMPLIES WITH THE REQUIREMENTS OF OBC SECTION 507. BUILDING IS FULLY SUPPRESSED AND COMPLIES WITH THE REQUIREMENTS OF OBC SECTION 507. APPLICATION #200029 FOR ADDITION FIRE SUPPRESSION IS APPROVED. APPROVAL FOR REAR BUILDING ADDITION AND RELATED SITE IMPROVEMENTS INCLUDING A PARKING LOT EXPANSION. SEE NOTES ON PLANS AND ALL ATTACHMENTS INCLUDING BOARD OF ZONING APPEALS BOARD ORDER #07-121V DATED 11/29/07. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 APPROVAL FOR REAR BUILDING ADDITION AND RELATED SITE IMPROVEMENTS INCLUDING A PARKING LOT EXPANSION. SEE NOTES ON PLANS AND ALL ATTACHMENTS INCLUDING BOARD OF ZONING This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number ..... 08-00200028 Date 4/28/08 Revision number . . . . . . . 2 -------------------------------------------------------------- Special Notes and Comments -------------- APPEALS BOARD ORDER #07-121V DATED 11/29/07. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600. *** IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE *** SIGNED CHIEF BUILDING OFFI CIAL Jeffrey S. Tyler, AIA -------------------------------------------------------------- Other Fees . . . . . . . . . SURCHARGE FEE - GAS LINE -------------- 2.10 -------------------------------------------------------------- Fee summary Charged Paid Credited ----------------- ---------- ---------- ---------- -- -------------- Due -------- Permit Fee Total 70.00 .00 .00 70.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 2.10 .00 .00 2.10 Grand Total 72.10 .00 .00 72.10 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. _'.. % CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 PLAN APPROVAL This is not a Building Permit. It is a record of our review of documents submitted with your application for a Building Permit. Date: March 10, 2008 RE: ADDITION to STANLEY STEEMER APPLICANT: Christopher P. John, Dublin Systems, 614-889-1445 APPLICANT NO. 08-200028(1) ADDRESS 5700 Shier Rings Road The plans, dated Dec 28, 2007 and revised 2-25-08, for the captioned project have been reviewed for compliance with the administrative provisions of the 2007 Ohio Building Code (OBC) and the 2008 NEC The review was based upon the following criteria: Use Group: B-Business/F-1 Moderate Hazard Factory :: Mized Non-Separated Area: 12,554 SF (Addition) Building Total 62,944 SF Occupancy: 126 @ 1:100 (Addition) Building Total 631 Occupants Construction Type: IIB Notes: Building is fully suppressed and complies with the requirements of OBC Section 507. APPLICATION # 200029 for ADDITION FIItE SUPPRESSION 1S APPROVED The architectural, documents are sealed by Victor D Irelan, Ohio registered engineer #28574, the pre engineered metal building by Carl W. Walker, Ohio engineer # 55712, the plumbing and gas piping by Patrick J.P. Kelley, Ohio registered architect # 5983, the mechanical by T. Partick Halaiko, Ohio registered engineer # 44588, and the electrical by James R. Hill, Ohio registered engineer #42045 to comply with the requirements of the OBC Section 107.3.4.1 and have been reviewed, therefore, in accord with OBC Secrion 104.1. OBC 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the building official or the building official's designated representative. The Drawings are APPROVED The following items are required for code compliance, but are not necessarily covered in detail in the construction documents. This list is a reminder to the design professional and contractors of issues, which are to be satisfactorily dealt with in the field: Item A OBC 105.7.2 Posting. The certificate of plan approval shall be posted in a conspicuous location outside of the building and in the front part of the premises on which is, or will be the approved building or equipment to which the approved plans relate. The owner and the contractor shall, so far as possible, preserve and keep the certificate posted until the completion of the work to which the approved plans relate. Item B OBC 106.4 Amended construction documents. If substanrive changes to the building are contemplated after first document submission, or during construction, those changes must be submitted to the building official for review and approval prior to those changes being executed. The building official may waive this requirement in the instance of an emergency repair, or similar instance. ADDITION to STANLEY STEEMER Permit No.: 08-20028(2) March 10, 2008 Page 2 of 2 Item C OBC 109.1 General. Construction or work for which an approval is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. This includes firestopping and draftstopping (Chapter 7 OBC), mechanical work; piping, ducts and systems (Chapter 3 OMC), structural members and connections (Chapter 16 OBC), and electrical work (Chapter 27 OBC). All systems and elements covered by code are to be inspected and approved before being covered. Item D OBC 1103.1 Where required. Buildings and structures, temporary or permanent, including their associated sites and facilities, shall be accessible to persons with physical disabilities. OBC 1103.2.1 Specific requirements. Accessibility is required in buildings and facilities, or portions thereof, to the extent indicated in ADAAG Section 4.1 and this chapter. Item E All electrical will comply with the requirements of Article 27 OBC and the National Electrical Code, NFPA 70, OBC approved edition and is subject to the approval of the electrical field inspector. Please reply to this request for additional information with a letter indicating your response to each item of this request and that of the Washington Township's Fire Department comments, if applicable. Once the requested information is available, submit Three (3) complete sets of the additional information requested to the City of Dublin, Division of Building Standards for further review. TO REQUEST AN APPEAL HEARING, YOU MUST sent a written request, listing the items to be appealed and the relief sought and a copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 ?wed and Signed, VU? M. arpham, AIA . yler AIA ?rn cial Plans Examiner Chief i ding Official 1W Owner or`Dwner's Representative Date '94'lw _ i 41Ii9-N'/44-&K ? Printed Name and Title as Signed NABuilding Standards\EIarpham\Reviews 2008\08-200028 a Steemer Add.doc . ? CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . .... 08-00200028 Date 4/03/08 Revision number . . . . . . . 2 Property Address .. .... 5700 SHIER-RINGS RD Parcel Number: 273-000885 Alternate Address: Tenant nbr, name .. .... STANLEY STEEMER Application type description COM BUILDING ADDITION ------------------------------------------------------------ ---------- ------ Application desc Sq Ft 12,554 ----------- ---------- -------------------------- Property owner ... ----------------------------- .... BATES PROPERTY MANAGEMENT LTD Contractor . . . . . . . . . DUBLIN BUILDING SYSTEMS --------------------- Structure Information 000 000 ------------ ---------- Construction Type . . . . . 2B - PROTECTED/NONCOMB Occupancy Type . . . -------------------------- . . . BUSINESS ---------------------------------------- ---------- Permit . . . . . . COMMERCIAL BUILDING PERMIT Additional desc . . Permit Fee .... 120 0 Plan Check Fee .. v .00 Issue Date . . . . ?- Z/-O Valuation . . . . 0 Expiration Date . . 9/29/08 Qty Unit Charge Per Extension BASE FEE 160.00 12.00 80.0000 THOU COM BLDG PLAN REVIEW ---------------- 960.00 ---------- -------------------------- Permit ...... ------------------------ LOW VOLTAGE ELECTRIC PERMIT Additional desc . . Permit Fee .... 270.00 Plan Check Fee .. .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 9/30/08 Qty Unit Charge Per Extension BASE FEE 30.00 12.00 20.0000 THOU COM ELECTRIC LOW VOLTAGE ---------- 240.00 ----------- ------------------------------------------------------- Special Notes and Comments PHASED PLAN APPROVAL #1 AND CORRECTION REQUEST #1 FOR ALL EXCEPT FIRE SUPPRESSION SYSTEM, GAS PIPING, AND ELECTRICAL. BUILDING IS FULLY SUPPRESSED AND COMPLIES WITH THE REQUIREMENTS OF OBC SECTION 507. BUILDING IS FULLY SUPPRESSED AND COMPLIES WITH THE REQUIREMENTS OF OBC SECTION 507. APPLICATION #200029 FOR This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number ..... 08-00200028 Date 4/03/08 Revision number . . . . . . . 2 Special Notes and Comments ADDITION FIRE SUPPRESSION IS APPROVED. APPROVAL FOR REAR BUILDING ADDITION AND RELATED SITE IMPROVEMENTS INCLUDING A PARKING LOT EXPANSION. SEE NOTES ON PLANS AND ALL ATTACHMENTS INCLUDING BOARD OF ZONING APPEALS BOARD ORDER #07-121V DATED 11/29/07. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 APPROVAL FOR REAR BUILDING ADDITION AND RELATED SITE IMPROVEMENTS INCLUDING A PARKING LOT EXPANSION. SEE NOTES ON PLANS AND ALL ATTACHMENTS INCLUDING BOAR.D OF ZONING APPEALS BOARD ORDER #07-121V DATED 11/29/07. SCREEN ALL MECHANICP,L UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600. *** IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE *** SIGNED ? CHIEF BUILDING OFFICIAL ef rey S. Tyler, AIA Other Fees . . . . . . . . . COM BLDG INSPECT NEW/ADD 1250.00 COM CERTIFICATE OF OCC 120.00 SURCHARGE FEE - ELECTRIC 8.10 SURCHARGE FEE - BLDG 74.70 ------------------------ Fee summary ----------------- ---------- Charged ---------- ---------------------------- Paid Credited ---------- ---------- -- -------------- Due -------- Permit Fee Total 1390.00 .00 .00 1390.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 1452.80 .00 .00 1452.80 Grand Total 2842.80 .00 .00 2842.80 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. 1(%/ 008) Jennifer Brock - Re: Stanley Steemer Page 1 From: Kristin Yorko To: Brock, Jennifer CC: Kauffman, Tina Date: 4/2/2008 1:01 PM Subject: Re: Stanley Steemer Good question...no this is an add on to an existing building where they do not need new services. Thanks for checking with me. Stormwater - It's cleaner in Dublin. Kristin Yorko, P.E. Civil Engineer City of Dublin 5800 Shier-Rings Road Dublin, OH 43016 (614) 410-4657 (614) 718-4346 (fax) kyorko@dublin.oh.us »> Jennifer Brock 4/2/2008 12:08 PM »> Are there any tap fees with this one? WASHINGTON TOWNSHIP DATE: FIRE DEPARTMENT 6200 Eiterman Road, P.O. Box 3248 Dublin, Ohio 43016 614-652-3920 • Fax 614-766-2507 I??Ct-1 VED March 14, 2008 TO: Jeffery S. Tyler, Director Division of Building Standards City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 ATTN: Ray M. Harpham, Commercial Plans Exarniner AIAR 7 " 2008 c,TyQF DIIB IN RE: Washington Tovmship's Fire Department Plan Review PROJECT: STANLEY STEEMER - NEW BUII..DING ADDITION APPLICATION No: 08-200028(1) LOCATION 5700 Shier-Rings Road RECEIVED: February 29, 2008 BUII..DING CODE DATA: Use: B/17-1, Office and Manufacturing. Construction: II B, Noncombustible / Un-Protected [Existing & New Construction] Area: 12,544 SF [Proposed Addition] 50,400 SF Total Building Area. Occupancy: 360 [Proposed Addition] 505 Total Building. Notes: Construct new slab-on-gratie pre-engineered building addirion, with new doors, minor plumbing and HVAC work with new electrical lighting and power requirements. The buiiding addition is proposed to be provided with an automatic fire suppression system. Mr. Ha.rpham: We have reviewed the Revised Construction Documents dated 02/22/08 along wit6 Response Letter dated February 12, 2008, as submitted to the Division of Building Standards January 11, 2008, for matters of concern to the Washington Township Fire Department regarding rules relating to the 2007 Ohio Building Code (OBC) and the fire prevention and the Dublin Fire Code(DFC) based upon the 2000 Intemational Fire Code. We aze able to recommend approval of the Revised plans as submitted. Thank you for the opportunity to review the plans. We aze pleased to make ourselves available to the developer and designers for questions and the discussion of altematives. WASHINGTON TOWNSHIP FIRE DEPARTMENT 114f 4i2?C6 a 6? ?_, Michael A. Boryca, Architect/Pls Examiner (614) 4884009 s:0= xcvivm\washi%tm rowns*ws-zaoozs(i) tvjpc a4lIJ C44,j%? Alan Perkins, CFPS Fire Marshal Trustees Gene Bostic • Denise Franz King • Charles Kranstuber Fiscal Officer Joyce E. Robinson Chief Allan Woo CITY OF DUBLIN 1% Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Date s z 4'? Lot No. Job Address J??? ??lg"P_ s?• parcel No -a2 7J ' e9nr v " s Subdivision Owner Nam4)L )W Telephone Ar-71- Contractor NamL4'ceS ?LE d-r'e/C Contractor Address3T ??p -5j Residential: New Sq. Ft. APPLICATION FOR ELECTRICAL PERMIT Application No. nli?. -Aocpn,?)-e) 74l0 - 3l?9-?Z 1 / Dublin Registration No. 00-3 ( Temporary Service $40.00............................................ ......... .<._. ................................................ $40.00 Minimum plus $20.00 for each ad al 500 Sq. ?'t. €?r fraetian theret?f t?ver 1000 Sq. Ft. Low Voltage Systems: Squar et $40.00 Mini p us $10.00 for each additiona1500 Sq. Ft. ax fraetian thereof over 1000 Sq. Ft. Commercial: New Sq. Ft. Alteration/Addition Sq. Ft. 1°21 ssy -730 • Temporary Service $60.00 .......................................................................................................................... ?'.. $60.00 Minimum plus $60.00 far each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. and up to 50,999 Sq. Ft. (sizes above, See Fee Schedule) Low Voltage Systems: Square Feet $30.00 Minimum (plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.) 3% State of Ohio Surcharge (commercial only) 34 Total $ JOB DESCRIPTION 'IICJ U!"l?d 4[7, f-%1-, o? This permit is granted on the express condition that the said work shall in all respects, oonform to the orciinances of the City of Dublin, all the laws of the State and the National Electric Code regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. Signature of licensed contractor or homeowner /Yi1d6.s&41 d/pl-.[-d-A-ZTi? Division of Building Standards nnn {-' Date: 1/1/2001 1 CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number ..... 08-00200028 Date 5/02/08 Revision number . . . . . . . 2 Property Address ...... 5700 SHIER-RINGS RD Parcel Number: 273-000885 Alternate Address: Tenant nbr, name ...... STANLEY STEEMER Application type description COM BUILDING ADDITION ---------------------------------------------------------------------------- Application desc Sq Ft 12,554 ---------------------------------------------------------------------------- Property owner ....... BATES PROPERTY MANAGEMENT LTD Contractor . . . . . . . . . DUBLIN BUILDING SYSTEMS --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . 2B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS ---------------------------------------------------------------------------- Permit . Additional Permit Fee Issue Date Expiration Qty 12.00 . . . . ELECTRICAL PERMIT desc . . SELLERS . . . . 780.00 Date . . 10/29/08 Plan Check Fee . . .00 Valuation . . . . 0 Unit Charge Per Extension BASE FEE 60.00 60.0000 THOU COM ELECTRIC SERVICE 1K-50K SF 720.00 Special Notes and Comments PHASED PLAN APPROVAL #1 AND CORRECTION REQUEST #1 FOR ALL EXCEPT FIRE SUPPRESSION SYSTEM, GAS PIPING, AND ELECTRICAL. BUILDING IS FULLY SUPPRESSED AND COMPLIES WITH THE REQUIREMENTS OF OBC SECTION 507. BUILDING IS FULLY SUPPRESSED AND COMPLIES WITH THE REQUIREMENTS OF OBC SECTION 507. APPLICATION #200029 FOR ADDITION FIRE SUPPRESSION IS APPROVED. APPROVAL FOR REAR BUILDING ADDITION AND RELATED SITE IMPROVEMENTS INCLUDING A PARKING LOT EXPANSION. SEE NOTES ON PLANS AND ALL ATTACHMENTS INCLUDING BOARD OF ZONING APPEALS BOARD ORDER #07-121V DATED 11/29/07. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 APPROVAL FOR REAR BUILDING ADDITION AND RELATED SITE IMPROVEMENTS INCLUDING A PARKING LOT EXPANSION. SEE NOTES This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. ' CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number ..... 08-00200028 Date 5/02/08 Revision number . . . . . . . 2 -------------------------------------------------------------- Special Notes and Comments -------------- ON PLANS AND ALL ATTACHMENTS INCLUDING BOARD OF ZONING APPEALS BOARD ORDER #07-121V DATED 11/29/07. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600. *** IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE *** SIGNED CHIEF BUILDING OFFI CIAL Jeffrey S. Tyler, AIA --- -------------------------------------------------------------- Other Fees . . . . . . . . . SURCHARGE FEE - ELECTRIC ----------- 31.50 -------------------------------------------------------------- Fee summary Charged Paid Credited ----------------- ---------- ---------- ---------- -- -------------- Due -------- Permit Fee Total 780.00 .00 .00 780.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 31.50 8.10 .00 23.40 Grand Total 811.50 8.10 .00 803.40 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN b? FAX Dave Marshall To: Development Review Specialist Review Services Phone: (614) 410-4600 Fax: Direct Line: (614) 410-4664 Date: Fax: (614) 718-4346 Page: Good Evening Bart: BART SELLERS / SELLERS ELECTRIC (740) 369-4378 December 20, 2007 1 of 5 Your proposal dated 12/18/07 to add exterior wall mounted lights at the Stanley Steemer Manufacturing building located at the northeast corner of Emerald Parkway and Shier Rings Road has been reviewed and approved by Land Use & Long Range Planning subject to the following conditions: 1. You must attach a copy of this entire fax, including all attached sheets, to the City of Dublin Electric Permit Application that you will file for the work described. Provided you do so, separate review of the electrical permit will not be required by Land Use & Long Range Planning. 2. The three (3) proposed 175 watt metal halide Lithonia "TWH" wall pack lights must be identical or nearly identical to the existing wall pack lights on the building and are to be installed as shown on the attached plan. 3. Two (2) stem-mounted 400 watt metal halide adjustable Ruud "FS3-16" flood lights will be located on the north wall with one (1) identical fixture on the east wall of the building. All three fixtures must be installed as shown on the attached plan. A fourth stem-mounted adjustable flood light shown on the west wall is not to be installed and is noted as such on the vlan. 4. PLEASE NOTE! Final adjustment of the two stem-mounted adjustable tlood light on the north wall is subj ect to the approval of the City of Dublin Code Enforcement Supervisor. If, in the opinion of the City of Dublin, the adjustable flood lighting causes glare and endangers motorists on Emerald Parkway or US Route 33 the City of Dublin reserves the right to require that the lateral and downward angle of the two wall mounted flood lights be adjusted as required to eliminate the unsafe condition. Please contact Code Enforcement Supervisor Greg Jones at (614) 410-4600 after the flood lights are installed. Please feel free to call my office if you have any questions regarding this review. I can be reached at (614) 410- 4664. I will be on vacation from 12/21 until 1/2/08. Velma Coen or Tammy Noble-Flading can assist you in my absence if necessary. Dave Marshall Development Review Specialist Cc: Greg Jones, Tammy Noble-Flading, Velma Coen, Ted Zombek, Jennifer Brock City of Dublin • 5800 Shier Rings Road, Dub,lin, OH 43016 • www.dublin.oh.us • E-mail dmarshall@dublin.oh.us FROM :SE-ILERS rLECTRIC FAX N0. :7403654378 Dec. 18 2007 09:44AM Pi Sellers Electric Co., Inc. P.O. Box 347 (Office) 740-369-3211 Delaware, Ohio 43015 (Fax) 740-369-4378 State License #20544 Cover Sheet nate 12/18/2007 Z'p bAVE MARSHALL Pages sent 5 FrOpl BART SELLERS Mx. MaRSxALI,, I DREW UP A PRELIMINARY SKETCH OF THE STANLEY STEEMER MFG. BUII.DIIr'G. IT SHOWS THE EXISTING WALL PACK F1XTLIRES AND TI-E NEW WALL PACKS A1v-D STEM MOUNT FIXTURES. IFEEL THAT ELTMIrIATIlNG THE 400 WATT STEM MOUNT FIXTURE IN ?HE NW CORNER AND ADDING THE THREE 175 WA1`,T' WAY,L PACK FIXTURES TO THE WEST WALL WILL PROVIDE ENOUGH LIGH'IZNG FOR SECURYTY PURPOSES. Tl-I(S WOULD KEEP UNWANTED GLARE AWAY FROM EMERALD PARKWAY AND SHIER R1NGS ROAD. CUT SHEETS OF TBE FIXTURES ARE iNCLUDED. PLEASE FEEL FREE TO CAT,L TF YOU HA.VE ANY QUESTIONS. BART A. SELLBRS SELLERS ELF,CTRIC COMPANY, iN'C. At?p ri 0 4`E D iJ I iO1 ED FROM :SELLERS FL.ECTRIC FAX N0. :7403694378 Dec. 18 2007 09:45AM P2 ? ? W ? S S-rA N L f::s? 5-M E?yl EFz CHAtN ?IUK FEuCE i I 'S'4? ? ? tr.???? ? I KI , -. ?? . ; E Ip ? -? ;A L ? A ? R 'P A R K ' W , ;q ?Y K ? N ?G ?L a ;7 ? i ! ? a i YhAAjUFACTvRiW, j wn o? ??-r,?- c.r+?u. -Ciug J-r,e-T (O UT? I ?-35 Pt.¢?T? o ? ? ?.? ?? ?c.D 3 tJew STEv? - Mnv ?/T` 4610 wAIr $'rAN1DmRo FlAb() LTS, T-\ ?- ---- ----------n-- Ex? S?r? N v ? ?? Wn17 rn.4. Wac(. PAcKS 3 NU:w rw H?'l 5 w A-tt' ?A,H, WNLL PACxs rATr?-?I NG. EKISnN(, ,..? i i ? , r ? 1 I ; G ?. A ' S s ! : ! t ? ? ; ? 0 I SH?PPti??G ' ? f i ?e?;EJ;N6 I t ? i .. ?._ ; ? 0 ? ? i ` ?,c;1'15 wn11' ; m, N, waLL PRGY S ? U? ? S Nr ER Ri N G5 i PA V-X.; N G L?T ? uz ?.r? N c? ? _._ ..,...?._.___..._.__., ?....-?..._._...?,_.,.:.,.......__...? ?, 5 rl lf:-R- R? N Gs :jz.d, n?' r ; ^? ? At ? r ???*':, :?S ??f,'i?,? -- 'Itltl ?z?ro/7 FRCM :SELLERS ELECTRIC Die-Cast Wall Packs, Giass Refractor FAX N0. :74036e4378 Dec. 18 2007 09:45AM P3 cP.? ? ,, f?..?, ?? ?/1 ?ii?? l -w ' J ?ti??'.e.el TWH :?. l?itended Use! For outdoor storage areas, warehouse and facto- ry perimeters and loadina docks. Contad wtth a direR forceful spray of water during operation can result {n glass breakage. Not recommend- ed for car wash applicatlons. ... . _ .. . .. , F.eatti res._: . _,.._ ._ .. Housing - Rugged, dle-cast aluminum housing. Corrosion-resistant captive exTernal hardware in- c{udes slotted hex-head fasteners. Standard fnish a dark bronze (DDB) corrosion-resistant polyester powder. Other architeaural celors availabie. Opttcs - Reflector Is specular anodized alumi- num. Refraccor is prismatic borosilicate glass. lens is sealed and gasketed to inhibrt entrance of outsidecontaminanK. Electrical - 70-150W HPS and too-15oM: High• reaaance, high-power facter. All o;her;: Con- stant-wattage autotransformer. Ballasts are Example: NVH 2505 TB LPI T - ? I _ . . . . _.;_ . . . . . . . . . . ... pOgnadon y?: • : Options NiCnpresstnsodum 120 InImlkm rn{ 7pS 2W $F $ingle fuse 126V, 277V. 347V (n/aTE or TBU) ny}{ ipps 2406 ff Oouble fuse, 208V, 240V, 480V (nla T6 or TBV) rn1 15U5 ZJl B Emuguxy cxculrn.n m{ ppps 347 ORS Quara restrike system1Q-" TWH 25ps sEpT CR Enhanredrorrosionresistance TWH 4005 TBo Gtt Non-stick protective waqnyIj Aletal n3fl4e iEV9 PE Pho!oalxtric cell - button type (n/a T8, TBV a 4G0) pmH lppM VfR NEMA twist-lak rec_-ptadell TWH 150b, PS Fullshield tYYH 175M 11Nf1WG Wlraguard" TWH Zppyt TIMFNG Vandal guard1° 7W{ 25py' SLSYA Super StWA puhe start ballast (150M•400M only: n/a 175M ) TWH 320M2 RHP Resctar hiyh-power Fscter baltast (HPS 150W & 6el,w only) TWH 35pW RHP Reactor nortnzl ;oowen cctor ballzv. (NPS 150W & below only,120V TWH 400IIt3 only) Memn va? 7(HP Reactance high•power (actor oallast (H!'S 150W & oelow anly) TWH 100" GSA CSA CeltUleC" TWH 175H MON NOIA CertifM (consitlt tattnry) iliM 250H lDl l2mp,nclu0e016 (nar pi? sadium l1lP Wl' hainp TWH 35l' 1P Tamperproof fasteners ?? Faapuoulmdihmralcol?,r,,cepn,?e5:3. TWH 30015.10 J.amp.?iiture Data ` DancmvnaesnoWnna+rt"(senGmeten)unlessomerwKenaee. Wahage:, BaUast' ;lamp[y?e Easerype : Hogne 15-114(e0) Hahorei<uresodiurtt dlrro?Iclearl w?cre is.ve(ai.? ;NX•NPP , E17 . ;, medium DrpT: eU0.31 100 '. HX kIPE: E1I, ..mediun , Wegt 26421tisp2-1qcq1 ...150• HX•tIPF 111 meclium W_? ; p J 75C? CWA; ? BT28 ? mog?l , ? . . - 400 t1NA .; Ei22 mcgt:l I h4rt?{Irallde(mcA(1S?1/nroallcarl:.. ` . i50 ; , H?•NPF - . E17 . medium ' h --•-- 115.; CWA ,BT28 'mog?t 250 tVVA ; BTZB mogul ' .! s00 , CWA:?: . EOo?8T18 ' m ?I aO LJTHON/A L/6NT1NO' www.litnunia com keylNOrd: TWN Copper wvena-a*ra ivv-m a???•???•??. -_ Listed. Electrlcal components mounted in hinged front cover that Includes primary and secondary elearical disconnecc. Socket - Glazed porcelain (mogul-based 175M and above; medium based: 1 SOM, 1505 and be- low), hor'pontally oriented with copper alloy, nickel•plated suew sheil and center contaci. UL lisced 660W, 600V for medium base; 1500w, 60oV for mogul base.4KV pulse rated. Insullation - Back housing is separated trom front housing, eliminating ballast weight and promoting easy handling. Top 3/4" threaded wfr- ing access. Back access through removable 3/4" knockout. Mount on any fla[, non-combustible vertlcal surface. UL Listed (standard). CSA or NOM Certified (see Options). UL Llsted for wet locations. IP65 rated (250W and below) or IP54 rated (400W1. 4xessoiles _ (Ordersep,;atel4) kl(1PEB1 PhomelectricmnvolkiL 120Y R1(1PtB't PhoroelecQicconaolkic,208V,240V,Z1N Rl(1 PFB7 CSA Phonelectricmrrttol kit 120V R10 PEB3CSA Pnotcelectiiccontrolkrt3dN RXITIYF1GlF5 FidGins6illablefuushidd.fornwN Pf1 NENAtwiS4odcphetvcontro1.120V,208V.240N' Pf3 N6MAMris:4ockphetocontrn1.347V' PfA NEMRtwrst•IOCxphotoconaoi,480V' PF7 NEMAtwis0ockphctocon7o1,277V? NO1S 1 lAapbcatSaedw+thSCNA, 2 I?iabe ads*eCurth SCWA, J RequunEDcr6728rvucea)ecketVemp < FbcawiuekwinT& 5 1209onry,A11 tamp. 6 Casurttaccoryrarava!ieditrymfanxi 7 fawltfxvry(urilaSiGtyinCrvd,.rtAISOAI. 8 OotcminWK•= o3ttac(110V.2OoVV.24W.ZI)1?.InLErism120U.lTN.347V: Sfups3s120Ur3:7`/, 9 OpGonNStapb?!lut(120VI06V:240Y.ZT7V.160h. D lampnounnurv. TI Ou.Yt+lunpwR.ye rot lauacdbalLvwniagerai ing. 4 Biaucfinishcnry L Pnotasll rauxluCea. N AoqAresiaadymocAeaaa. b NcaaYaiLDok-,.*1TBV. 6 Ne[.w?bh!ew?th?ndoanl. P FERmucDOxrrCwaANriwt. -0 pU1p(pAllft)y?8:ld7DIF. ligh tquick'" fxpress delivery products. See Faye 11 for deWiis abaut light0uick X0. I TWN 2501E T8 lPl I TWH 400hC TB LPI Rev.1 I/Ofi PSG9 Ordering Information FROM :SELLERS ELECTRIC FAX N0. :7403694378 Dec. 18 2007 09:46AM F4 . . _.. , n4uomew Fltwr D'scast aWmeum tnuclcb b 72eo br 7 pIpo Cl.w (BO mmj QD.) Finrlt cukr Dron2e i i O PULSE STAAT METAL NALIOE ? 200W PSMH Fa3620-(a)(6) ? 250W PSMH FS3625-(a)(b) 0 320W PSMH ? FS3632-(2)1bj_ ED 350W PSMH FS3635-(a)(b) 400W PSMH FS3640-(a)(b) METAL HALI DE 0 175W MH .. _-1`53417-(a)(b) [] 250W MH fS3425-(a)(b) 0 400W MH FS3440-(a)(b) HIGH PRESSURE SOOIUM 0 250W HPS FS352510b) F-I 40OW HPS FS3540-00) _ Spectry (a) votope 8 (o) Op60ro 2" ADJUSTABLE FITTER 16" (406 mm) STANDARD FL00 ? 71 Standard floodlight luminaira for HID lamp, totally enclosed. Housing is seamless, d?e-cast aluminum_ Aluminum d'arcastadjuslable ritter mourrbna is sited fur 2' oipa (2-314• (60 mm) O.D.). Allows for direcGonal aiming zs viell as 2-112° incremental vertical adjustment. Contains integral wiring compartment Two stainless-steel set screws prov(de clamving to vertical tenons. Lens assembiy consis(s of rigid aluminum frame Exctusive De(taGuarcN finish features an E-coat zpoxy primer ;..edium brcrz2 Ua•d u,abla powder topcoat, providing excellent resistarce :c co:rosion, u!travio(e: deg;2datior, 2rd abrasion. The finish is covered by our seven-year limited rrzrranri. BotS? Pstunaa Ninya nacumhly 1 M T 120l208/240/277V (Swndard) 1201277/347V tCanatla Only) (Standarc) 1 12CV 2 _ ...-- w ?277V '- 27 277V Reactor (PSMH On(y) 3 4 20BV 240V ---._.._.,.._ 5 460V 6 34N (Canada Oniy) Por voNaqr, avxllabil;b oukiAe the US anC Catuaa. xe Bulietn TD•B or eor,tact your Auud UpnNnp ae0orfiad Intornstlonal Diwibutor a Fixture includes clear, moqul-base lamp. Pulse-rated porcelaln enclosed, 4kv-rated screw- she{{-type lamphalder wiM sprSng-loaded center ContaCt Lamp ignitor included where required. All ballast assembues are high-power factor and use the tQllowing circuit type: Reactor (277V PSM H) 200 - 400W PSMH CWA - Constanf Wattage Aufotranslormer 200 - 4001N pcMH, 175W -400W MH; 250 - 400kIV 4P5 US 4 689,77.9 , 1' I i ry- -d •(a)F Fusing _ -SP External Photocell (ior aeov) M Q~" Quartz Standby (includes 1bOW auartz IamD) (wA on 2m Reactor) u Uplight Lens Frame Specffy (a) S,ctgle Voltape - Sae Voltpu Suffuc Kay T. ANSI lamp wattage label supplied, visible during rolamping. UL Lisbed in US and Canada for wel locations and enclosure classfied IP65 Der IEC 529 and IEC 398. ACCESSORIES DB-16 Dsep Baffle FlNG-16 GS-15 Wlre Guard Glzre Shield tS-is PC•1 Potycarbortate Vandal Shlefd fnp; `qr use w;th 5kwras in up,Kht positien) Button Photocell i ~ +? (fur fiaturas sat to 120V) PC'o Button Photocell tfor ri?:re. C4« «-^ Z,714 PC•2 Bu:tol Pi;otvCZ!I M.? (ror rixtures sat ro 208,240,277V) r Psv7- ? uround Mount Post 9201 Washmgton Avenue Racine, Wisconsin 53406-3772 USA PHOh1E (262) 886-1900 FAX (262) 884-3309 0 Ruud Ughtiq Inc. Prlnted In USA LIw,w.ruudli9hdnp.com 12111j03 RuuD? LIGHTING FROM :SELLERS BLECTRIC FAX N0. :7403654378 Dec. 18 2007 09:56AM P1 ? 2" ADJUSTABLE FITiER 16" (406 mm) STANDARD FLOOD EPA RA71NG Isofooccandle plots show initial footcandles at grade. (Footcandles = 0.0929 = Lux) EPA 1.78 for single fixture with 60° tilt (Consult factory for EPA rating on muitipie units or other tilt angies). 2AOCO 22000 20000 18000 4NN,saoo W ?4000 ? 17J00 u lopoo 9000 6000 eood 2000 Vl.dCsj HotSZOnGN -- • eo so +o W o x m eo eo ANGLE (IN DEGRFES) LigMng S1ciGxe3 {m. Certffied Test Re9ort No. LS15B03 CanAlepmer Irace tlx'ou§h origin of 40QIM MH Standenl FlOOdlighd NE7NA Trpe: N = 7H 24000 22000 Yoooo 1dOQJ i5aoo 5 i'°o° a 12000 8000 6J?0 e000 2000 tf -- -- 1-y 160' 4110 42.7 7aa 12f1' 100' 36.6 30.5 • 4 20 gp • , 1 G3 60 44Y 12.2 6 1 29 • , 0 m p 20. 6.1 ,0. 12.2 90.5 2a4 1&° 122 6,1 Om 13.1 122 7113 24.4 90.5 tsobotcandle plot ot 250W MH Standard FlondligM ai 25' (7.B m) mauMinA heiAAl and 60° vertical tilt (Plan view) too• eo• so• do' aa V N ao• 60• ae' -1 ar " 160' do .B 1e0' 42.7 120' 36,6 ' 5 50 100 . a 2s ? . • 18 3 60 . ,y0, ff - _ ? R 12.2 1 E 211 . p• 0 m gp• 6.1 4p• 30 5 2 " 1&3 12.2 6t Om 6.1 12 21 1 93 24.4 X 12.2 S 100' W 60• 40' 20' 0' 20' 40' 60' 80' 100' t m tee' 120' i 00' ev 60, 49 W a 20, 40' ? 4a.e 427 ._.? .._r ? 3a.s . I 30.4 _ I .._...I i ......` ? .3 ? _.?...._. ' $6A ?Z1 ._. .? . j ... . ? .. + .. ?. .. ? 6.1 . ? ? . . I . I ? . On di ? 12J xt4 24A 18.3 122 61 Om Gt 122 183 24,4 M5 IsatoatprMle plot ot 400W MH Staadard FluodligM at 30' (9.1 m) mounting heigM arrd 60° rerUcalltit (Plan rlew) ,oo' sa eo• 40' za• o• 20• ae• eo• so• 1oo• , w 140' 48.0 d2.7 120' 36.6 100' 30.5 pq 7a,d t 8 3 gp 40 20' ry . 12.2 &1 Om w 1 6 a • , 12 2 . o 30S 24.4 16.3 172 Gt Om V 22 183 291,4 30.5 Liawag Sdeam tElf, tsatootcaodle plof o1250W HPS StandarE tsotoctcandlo plot ot aoaw FiPS Standard ' Certfl{ed 7est pepat No. LgI g65a Fioodlighl al 25' (7.6 m) mounih?g helgAt ° (9.1 m) mountfop QeigM RooClfyM a130 aod 60' rerUcai dh (Ptan vlew) Candlepower trace Orough origin oi rertlcal tiH (Plan rler) and 60 480W HPS Staedard Aoodtigm MBAA Tryr. Bv z 7ti Pole-spacing Example Data i M Levels at Grade I illal LI A ? g verage n 4 Fxlures per pole 1e5t arci a =L,,ce wiofn a(1b1 ock tayaA (FwmandWs _ O-M _Lux) catal.1109 ; lsnry Tppe Lamp Lumens Mourding Neigid Ma:. Resommended PolL-spad ng Foatcaedies Lun FS3417-M 175W MH 14,000 15' (4.6 m) 20' (6,1 m) 75' (22.3 m) 100' (30.5 m) 6,11 66 3.35 36 FS3425-M 250W MH 21,000 20' (6.1 m) ' 100' (30.5 m) ' 5.38 58 19 34 3 (7.6 m) 25 (38.1 m) 125 . FS3440-M 460W MH 3fi,000 r ? r 25' (7.6 m) ' 125' (38.1 m) ' 5.48 59 96 43 3 30 (9.1 m) (45.7 m) 150 . ? F53525-M 25U1M11 HPS 28,500 20' (6.1 m) ' 100' (30.5 m) ' 76 7.08 4 35 47 (7.6 m) 25 (38.1 m) 125 . F$354o-M 400W HPS 50,000 '"' 25' (7.6 m) 125' (38.1 m) 7.63 82 ..?,. 30' (9.1 m) ?,..r.,... 150' (45.7 m) 5.45 _?........_59 s R`-' `-' D 9201 Washington Avenue Racine, Wlsconsin 53406 3772 USA PHONE (262) 886-1900 fAX (262) 884-3309 LI GHTI N G 0 Rwd Uphtlrtp Inc. PARted In USA wwwn;udiiphdnp.ccm 12111/03 rs sa % +e o+e 31 se n aNGLE (M DEGFEES) r ,t ? GEOTECHNICAL CONSULTANTS, INC. g?'-';?-'ooa,2 V"' RECEIVED APh 2- 5 200,? FOOTING OBSERVATION REPORT PROJECT: Stanley Steamer Addition DATE: 04/16/08 JOB NO.: 14691 5700 Shier Rings Rd - Dublin, OH CLIENT: Dublin Building Systems WEATHER: Clear/65 degrees OBSERVATIONS: Footing soils were evaluated visually for foundation support. Soil bearing at footing elevation was verified using applicable testing methods and procedures. The following test data and observations were determined. 1) FOOTING LOCATION: 2) PERMIT NUMBER: (If Applicable) 3) FOOTING ELEVATION (DESIGN 1 UNDERCUT): 4) FOOTING BEARING ON (FILL / NATURAL): 5) VISUAL SOIL CONDITIONS Perimeter wall footings D-1 to A-7 and A-7 to A-4 N/A Design and undercut (see comments below) Natural and fill soils (see comments below) Stiff, light water seepage noted at D-1 6) AVERAGE SOIL BEARING (P.S.F.): 7) REQUIRED SOIL BEARING (P.S.F.): 1,500+ 1,500 8) CONCRETE TEST CYLINDERS CAST? No (YES I NO): 9) COMMENTS: As requested a GCI representative arrived at the referenced site to observe bearing conditions for the proposed steel skin pre-engineered building addition. Fill for the pad addition was recently placed by Dublin Building Systems. No compaction records were available although observation of heavy equipment operating on the subgrade indicated firm conditions generally associated with controlled fill placement. Foundation soil bearing was determined by the use of a 0.5 inch metal probe rod and a manual use penetrometer. Dimensions were found in general accordance with the approved foundation drawings maintained on site. Some over excavation was required due to unsuitable natural soils (D-1 to C-1 undercut 2 feet below design grade) and existing asphalt from an abandoned drive (A-4 to A-3 undercut 1 foot below design grade). The remainder of the foundations were placed at grade in the stiff fill. Foundation steel and dimensions were approved by the City of Dublin, Ohio in the early P.M. CC: DBS (2) TECHNICIAN: Bob Hiles Offices: 720 Greencrest Drive- Westerville, OH 43081 (614-895-1400) (Fax 614-895-1171) 3570 Intercity Drive- Dayton, OH (937-235-0321) ** 8433 South Avenue- Youngstown, Ohio 44514 (330-965-1400) -t ? GEOTECHNICAL CONSULTANTS, INC. FOOTING OBSERVATION REPORT PROJECT: Stanley Steamer Addition DATE: 04/17/08 JOB NO.: 14691 5700 Shier Rings Rd - Dublin, OH CLIENT: Dublin Building Systems WEATHER: Clear/67 degrees OBSERVATIONS: Footing soils were evaluated visually for foundation support. Soil bearing at footing elevation was verified using applicable testing methods and procedures. The following test data and observations were determined. 1) FOOTING LOCATION: 2) PERMIT NUMBER: (If Applicable) 3) FOOTING ELEVATION (DESIGN / UNDERCUT): 4) FOOTING BEARING ON (FILL / NATURAL): 5) VISUAL SOIL CONDITIONS Perimeter wall footings A-3 to A-1 and A-1 to D-1 N/A Design and undercut (see comments below) Natural and fill soils (see comments below) No water seepage noted 6) AVERAGE SOIL BEARING (P.S.F.): 7) REQUIRED SOIL BEARING (P.S.F.): 1,500+ 1,500 8) CONCRETE TEST CYLINDERS CAST? No (YES / NO): 9) COMMENTS: As requested a GCI representative arrived at the referenced site to observe bearing conditions for the proposed steel skin pre-engineered building addition. Fill for the pad addition was recently placed by Dublin Building Systems. No compaction records were available although observation of heavy equipment operating on the subgrade indicated firm conditions generally associated with controlled fill placement. Foundation soil bearing was determined by the use of a 0.5 inch metal probe rod and a manual use penetrometer. Dimensions were found in general accordance with the approved foundation drawings maintained on site. Over excavation was required due to unsuitable natural soils (D-1 undercut 1 foot below design grade). The remainder of the foundations were placed at grade in the stiff fill. Foundation steel and dimensions were approved by the City of Dublin, Ohio in the early P.M. CC: DBS (2) TECHNICIAN: Bob Hiles Offices: 720 Greencrest Drive- Westerville, OH 43081 (614-895-1400) (Fax 614-895-1171) 3570 Intercity Drive - Dayton, OH (937-235-0321) ** 8433 South Avenue - Youngstown, Ohio 44514 (330-965-1400) , f ? ? GEOTECHNICAL CONSULTANTS, INC. FOOTING OBSERVATION REPORT PROJECT: Stanley Steamer Addition DATE: 04/21/08 JOB NO.: 14691 5700 Shier Rings Rd - Dublin, OH CLIENT: Dublin Building Systems WEATHER: Cloudy, 58°F OBSERVATIONS: Footing soils were evaluated visually for foundation support. Soil bearing at footing elevation was verified using applicable testing methods and procedures. The following test data and observations were determined. 1) FOOTING LOCATION: 2) PERMIT NUMBER: (If Applicable) 3) FOOTING ELEVATION (DESIGN / UNDERCUT): 4) FOOTING BEARING ON (FILL / NATURAL): 5) VISUAL SOIL CONDITIONS: 6) AVERAGE SOIL BEARING (P.S.F.) 7) REQUIRED SOIL BEARING (P.S.F.): 8) CONCRETE TEST CYLINDERS CAST? (YES / NO): 9) COMMENTS: R E C E I V EInterior column footings at lines A-2 to A-6 N/A Desigri Natural soils No water seepage noted 1,500+ 1,500 No As requested, a GCI representative arrived at the referenced site to observe bearing conditions for the proposed steel skin pre-engineered building addition. Fill for the pad addition was recently placed by Dublin Building Systems. No compaction records were available although observation of heavy equipment operating on the subgrade indicated firm conditions generally associated with controlled fill placement. Foundation soil bearing was determined by the use of a 0.5 inch metal probe rod and a manual use penetrometer. Dimensions were found in general accordance with the approved foundation drawings maintained on site. Foundation steel and dimensions were approved by the City of Dublin, Ohio in the late A.M. CC: DBS (2) TECHNICIAN: Bob Hiles Offices: 720 Greencrest Drive - Westerville, OH 43081 (614-895-1400) (Fax 614-895-1171) 3570 Intercity Drive - Dayton, OH (937-235-0321) ** 8433 South Avenue - Youngstown, Ohio 44514 (330-965-1400) . S,nt By: GCI; 614-895-1171; Apr-24-08 12:48; Page 2/4 t GEOTECHNICAL CONSULTANTS, ING. FaOTING pBSERVATION REPORT PROAC7: Stanley Stcamer Addition bqTE: 04/21/0$ JOB NO.: 14691 5700 Shier Rings Rd - Uublin, UI I CLIEN7': llublin Building Systems WEATHER: Gioudy, 58°F 013SEFtVATIONS: fboting sniEs were evaluated vibually for foundation support. Soil bcaring at footuig elevation was verified using applica6le testing mcthods and procetiures. Thc following test dat}t and observations were determinecl. 1) F06T1iVG LOCATION: In#erior calumn footings at lines A-2 to A-6 2) PERMIT NUMBER: N/A (if Applicab{e) 3) FOQTING ELEVATION T3QSign • (DE016N / UNDERCIIT): 4) FOOTING BEARING ON Natural soils (F1LJ. ! NATURAL): 5) VISUAL SOIL. CONDITI4NS: No water seepage notcd 6) AViRAGE $QIL BEARING (P.S.F.): 1,500+ 7) RF-QUIRED SQIL BEARING (P.S.F.): 1,500 8) COIVCRETE TEST CYLINbr:RS CAST? No (YE$ ! NO): 9) COIiItMENTS: As reqdested, a (iCI representative arrived ai the refirenced site to observe bearing conditions for the proposed steel slan pre-engineered building addition. T'ill foC the pad addition was m-eently placed by Dublin Building 5ystems. No compaction records were availab.je altliougli orscrvatian of heavy eguipment operating on the subgrade indicated firm conditions gcncrally associatcd with eonlrolled fll plac:ement. Foundation soil bearing was determined by the use of a 0.5 inch metal probc rod and a rnanual use penctromctcr. llimcnsions were found in generat accordance with the approWed fuursdation clrxwingv maintaineil c,n raund0ion steel ond dimensinns were appravcd by thc Gity o.f Dpblin, Ohio in thc late: A.M. CC: T?T3S (2) 7ECFiNICIAN: 13OY Hiluy Ualiccs: 720 Greencrest Drlve- Weatervllle, OIl 43081 (614-893-1400) (Fax 614-895-1]71) 3570 Inttrcily Drire - Dryhm, OIl (937-335-032)) " 99433 ."wulh Avenue- Yuungatnwn, nhin 44514 (330-90-1400) 5ent i ? By: GCI; 614-895-1171; Apr-24-08 12:48; Page 3/4 GEC)TECHNiCAL (DICONSULTANTS, INC, FOQTING 4BSERVATiON REPORT PROJEGT: Star,lay Steanier Additiun DATE: 04/17/08 JOB NO.: 14691 ' 5700 Shier I2inRs ticl - Uublin, 011 CLIENT: Dublin T3uilLling Systents WEATHER; C'Iear/67 degrces OBSEkVATIONS: Fuotino soils were evalua.tcd viyually for faundation suppnrt., Sail beflring at footinb clcvation wati verified using appliciblc tcsting mel.hods ond proccdures. The f(illnwing test data and uhscrvations were deterTnined. 1) FC 2) PE (If 3) FC (pl 4) FC (FI 5) VIl G LOCATION: YfIT NUMBER: iplicable) TING ELEVATlON IGN I UNDERCUTj: TING BEAF2ING ON ! NATURAL): AL 501L CONDITIONS: Perimeter wall footings A-3 to A•1 ancl /1-1 I.u U-1 N/A Uesign and undercut (see comments hclow) Natucal and fil) soils (see comments below) Nn watcr secryage iiotcd fi) AV?ERAGE 501L BEARING (P.S.F.): 1,500+ 7) REOUIRED SOIL BEARING (p.S.F.): 1,500 8) CdNCRE7E 7F-S7 CYLINdERS CAST7 Nu (?r?s i r?o), 9) CaiMMEN7S: As requested a(;('.l representative arrived at the referenced site tu observe buarink cunilitinns f'or the praposed s1eYl sk,in pre-4nginccrr;cl huilciirs?.? N(Id1LIilf1. ('ill fn1• the pad addition was recently placed by C)ublin [3uilding Systeizis. No compactioii rGC:ords wcri: available although obsetvation of heavy equiprn4nt. op4rating on the subgrade indicHled firrn uouditionn genertiJly associated with controlled fill plxcnmenl. Fuund#tion soil bcaring wfls determined by the use of a I).S ia,ch rnct.al rrohe rod and a manutil use pcnc4rornCtcr. Dimerisioes were found in genc:ral accordance with the approved faundatior? drawings maintained on sile. Ovcsr excnvation was required duc to uclsuitahlc natural soils (L)-l undcrcul 1 Root bclc>w design gracie), 'I'he remaillder of the foundatiuns were pIKCCt1 At grade in the stifl'till, h'oundzttion stucl ,and diirtcncion5 were approved by thu City (if 17ubl+n, t)hio in the early I'.M CC: p[3S (2) TECHNICIAN: Bob l liles Affices: 720 Greeucrest I)rive - Wextrrville, UH 43081 ((it4-895-1400) (Cnx G 14-875-1171) 3570 InIC?cety Drivc- Uryluu, OII (937•235-113E1) *" 8433 5outh Avcisue. - YOunkstuwn, Uliio 44514 (3311-965-I400) ? Sent By: GCI; 814-895-1171; Apr-24-08 12:48; Page 4/4 G GEOTECHNICAL CCJNSULTANTS. INC. FQOTING OBSERVATIDN REP4RT PROJtCT: Stanley Stenmcr Addition DATE: 04/16/08 JdS NO.: 14691 ^ 5700 Shier Riuga Kd - Utiblin, 014 CUF-NT: Dublin 13uilding Systc:rTts WEATHER: Clear/65 dcgrccs OBSEItVATiONS: Foolini soils werc cvAlualed visually fiir fiiiuniint.iun yuppotl. Soil be.aring at R.tioking elevation was vcriiicd using appliceble tetiting methods nnd prcfcc:dures, 'I'he following test data and ohservations vvere clcteririincd. 7) FQQTING LOCA71dN: Perimeter wall fi7u(ings D-1 to A-7 and A-7 to /1-4 2) PORMIT NUhABER: N!A (If Applicable) 3) FQ071NG ELEVATION DesiAn and uncicrcut (see comments below) (DO51GN / UNDERCU7): 4) F4U71NG BEARING ON Naturai and fill soils (see comments below) (FIk.L 1 NATkJRAL): 5) VIgUAL SOIL CONDITIdIVS: Sliff, lighl wal.er seepage noted at U-I 6) AVP-RAGE SQIL BEARING (P.S.F.): 1,5004- 7) REiQU1FtEl7 S4fL Br=AFtING (P.S.F.): ],SUC) S) GONCRETE TEST CYLINDERS CAST? No (YES / IVO): 9) COMMENTS: As reqitested a('rC'1 repeesentatiVe Arrived at the refereneed site ta observe bearing cnnditions for the proposed tit.i:cl ?&in Pr4-cnginccri;d huilding,tdtlil.icm. Fil] far the pad addition was recently placed by Uublin Building 5ystems, No compsct.icm rccc?rds werc $vailable although observatioii of heavy equipment operaling on the subgiade indicated f'trrn cotirliliuris gcttcra'!ly associated with contro{led till plaeement. Fuund9iion sc>il bcarirtg wsss dctcrmincd by thc use. of 8 0.5 II1CIl qletAl pCOLie POd Flll[) El 111Fi11Ui1) IISe penel.romef.ri". Uimensicros were found in ganeral accordancc. with thc appri,ved i'oundation drawi»gs mAintained on site. Some over ercavation was requircd due to unsuitablc naturxf soilti (1)-1 ln C-I undcrcui 2 tcet below design grade) and existing asphalt from an abandaned drive (n-4 ta A-3 imdr:rcut. 1 fi>ol boltiw dcsign giude). The remainder aF the fnundations were placed at gr•ade in the stiff fill. Nbunciittion sl.eel and <limentiion;, were approved by tlrc Ciry af Dublin, Uhio in the early I'.Nf. CC: pI3S (2) 7ECHtVICIAN: E3ob 1-liles Ulliccs: 720 Grcr.ncrest 1)rirr- Weslrrvillc, Oll 43081 t614•895-14001 (Nnx 614-895-1171) 3570 Lttcr'clty I)I'1vC OAytun. UH (937-2,3540321) "" 84J3 Suulh Aveiwc- Ynuug,YloWn, Ghio 445I4 (330-765-1,I00) _.? CIfiY OF DU'BMIN. Lcna u:e ana Lonp Ranye Plandnp 5800 Shier-Rings Road Dublin. Ohio 4301 6-1236 Phone/ TDD: 614-410-4600 Fax: 6144144747 Web Site: www.dublin.oh.us NAME OF BUSINESS/ FACILITY (IF APPLICABLE) ST-AhJ W STEEM E'!e. ADDRESS OF SUBJECT PROPERTY STaD Sl-?? 612 a g?'..,bar-> NAME OF APPLICANT/ AUTHORIZED AGENT RtSToPVE I DSS PHONE A-889- 5 ADDRESS OF APPLICANT/ AUTHORIZED AGENT (pZ-33 Ra. ?v1?wa <=)41 43o/Co NAME OF PROPER OWNER PHON -71o4-2pc>? PLEASE DESCRIBE IN LAYMAN'S TERkIS THE EXISTING AND PROPOSED USE(S) OF ALL PARTS OF THE LAND AND/OR BUILDINGS.1F A CHANGE OF USE IS PROPOSED, PLEASE EXPLAIN. (IE, RE7AIL SPACE TO MEDICAI OFFICE SPACE, ETC.) J - 1'id 0c + z S ? , AauFA&rv1 1 At>12, N J rb .4t- Extsr? c? o???c?; ,4No Nt?av???7v?.F??j ??c,?L?rY. FILE COPY CERTIFICATE OF ZONING PLAN APPROVAL APPUCATION # 00 - ZcR2 d0-8 DATE ISSUED PLEASE SUBMIT THE FOLLOWING: ?110 ONE (1) ORIGINAI. SIGNED APPLICATION ONE (1) COPY OF A SCALED SITE PLAN DRAWN IN INK indicating all current and proposed land uses, structures, and oiher site improvements. Additional documentation may be required for various types of projects. Partial or incomplete appiications and drawings cannot be processed and wili be returned to the appiicant by maiL t??sJ4,?? ? 1?85 // $/7.t9p8 FOR O17 - /? ( v rt /"/0 DATE r,orES: Screen All Service Struceure;3 & Mechanical Unots PrW Te f.onWwdlon PER CfTY CODE . REAo nu PERMIT coNOITIoNS CALL PLANNING DlViSION AMO/OR NOTES OIY APPROVEO PIANS ZONING INSPECTION REQUIRED UPON COMPLETION? YES NO If yes, please call 614410-4680 to schedule an inspection. A Certificate of Zoning Compiiance wiil be issued after the work is inspected and approved by Land Use and Long Range Planning. APPROVED This Certificate of Zoning Plan Approval is issued for, ai Administrator or designee, or the City Council, Board of appropriate. -41 APPROVED AS NOTED )ference to the pro ert se described above, and as approved by the City ? ppea s, annmg & Zoning Commission, or the Architectural Review Board as DATE: CERTIFICATE OF ZONING PLAN APPROVAL 3/10/2006 Ofrice February 7, 2008 UNIFIED RESPONSE LETTER (URL) Mr. Christopher P. John Dublin Building Systems 6233 Avery Road Review Services Dublin, OH 43016 5800 Shier•Rings Road Dublin,oHa3o1s-1z3s Re: Dublin Permit Application #08-200028 Phone:614-410-4600 Stanley Steemer Fax:614-718-4346 www.dublin.oh.us Dear Mr. John: The City of Dublin's Review Services Team has completed review of materials submitted January 11, 2008, for your request for a Commercial Permit. At this time, the overall review status is disapproved and the building permit is denied. The outcome of each review is as follows: Ohio Building Code - phased approval (plan review letter attached) Dublin Fire Code - favorable (plan review letter attached) Site Engineering Standards - disapproval (plan review letter attached) Zoning & Landscape - disapproval (plan review letter attached) Note the Building Plan Review Letter is not a Building Permit. Please provide a unified resubmittal responsive to the attached review letters consisting of four (4) updated and complete plan sets and the disapproved marked up check prints to our Building Permit Window, 5800 Shier-Rings Road. To facilitate review of your resubmittal, a written description of your responses to the itemized plan review letter comments (and other plan changes you may propose) is requested and recommended. I am available to handle general status and procedural questions. Technical questions pertaining to the plan review letters may be directed to the appropriate plan reviewer. Sincerely, Steve A. Snyder, P.E. Review Services Coordinator SAS/df Attachments CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 CORRECTION REQUEST #1 and PHASED PLAN APPROVAL #1 For ALL EXCEPT FIRE SUPPRESSION SYSTEM, GAS PIPING and ELECTRICAL This is not a Building Permit. It is a record of our review of documents submitted with your application for a Building Permit. Date: February 5, 2008 RE; ADDITION to STANLEY STEEMER APPLICANT: Christopher P. John, Dublin Systems, 614-889-1445 APPLICANT NO. 08-200028 ADDRESS 5700 Shier Rings Road The plans, dated Dec 28, 2007, for the captioned project have been reviewed for compliance with the administrative provisions of the 2007 Ohio Building Code (OBC) and the 2008 NEC The review was based upon the following criteria: Use Group: B-Business/F-1 Moderate Hazard Factory :: Mixed Non-Separated Area: 12,554 SF (Addition) Building Total 62,944 SF Occupancy: 126 @ 1:100 (Addition) Building Total 631 Occupants Construction Type: IIB Notes: Building is fully suppressed and complies with the requiremenis of OBC Section 507. The architectural, documents are sealed by Victor D Irelan, Ohio registered engineer #28574, the pre engineered metal building by Carl W. Walker, Ohio engineer # 55712, the plumbing and gas piping by Patrick J.P. Kelley, Ohio registered architect # 5983, the mechanical by T. Partick Halaiko, Ohio registered engineer # 44588, and the electrical by James R. Hill, Ohio registered engineer #42045 to comply with the requirements of the OBC Section 107.3.4.1 and have been reviewed, therefore, in accord with OBC Section 104.1. OBC 107.3.3 Phased approval. The building official shall issue an approval for the construction of foundations or any other part of a building or structure before the construction documents for the whole building or structure have been submitted, provided that adequate information and detailed statements have been filed complying with pertinent requirements of this code. The holder of such approval for the foundation or other parts of a building or structure shall proceed at the holder's own risk with the building operation and without assurance that an approval for the entire struchue will be granted. Such approvals shaU be issued for various stages in the sequence of construction provicled that all information ancl data required by the code for that portion of the building or structure has 6een submitted. The holder of a phased plan approval may proceed only to the point for which approval has been given This Phased Plan Approval is for ALL EXCEPT FIRE SUPPRESSION SYSTENI, GAS PIPING and ELECTRICAL Item 1 Fire Suppression Drawings shall be submitted for review; contain all information required by NFPA 13-2002 Chapter 14; and be approved before any equipment is iristalled or remodeled. A separate Permit from the ciry of Dublin is required. Item 2 401.4 Additional appliances. Where an additional appliance is to be served, the existing piping shall be checked to determine if it has adequate capacity for all appliances served. If inadequate, the existing system shall be enlarged as required or separate piping of adequate capacity shall be provided. a. Provide a complete description of sizes of all piping and a gas piping isometric. Locate ADDITION to STANLEY STEEMER Permit No.: 08-20028 February 5, 2008 Page 2 of 3 drips and sedimerat traps, shut-off valves, meter valves, and pressure regulator ('f required). Ident? rype of gas and gas piping, slope of piping (if required), Inlet Pressure, Pressure Drop, Specific Graviry arid IFGC Table utilized for piping calculations. b. Confirrri the existing 2" gas lirte capaciry to provide for ari additional 450 MBH at aia additiortal 146 ft +/-. Calculate required pipirtg sizes from the existirig gas rneter to the farthest-niost appliance as required by IFGC 401.4 Item 3 OBC 1301.1.1 [Energy Efficiency] Criteria. Buildings shall be designed and constructed in accordance with the applicable provisions of the 2006 Internatioraal EnerD, Cofiservatioti Code or the require»zettts of the 2004 ASHRAE 90.1 listed in Chapter 35 of this cocle a. Tlie lightirtg compliance Certificate was based upon the 2003 IECC rather than the 2006 IECC. Please revise the compliance certificate and resub»iit. b. Please also review the Controls, Switching and Wiring sectiotl of the Certificate aild confirni conipliance witli each of the applicable reguirentents of that sectiort. Item 4 Please confirni that the emergency egress lighting proposed will coriform to the reqatirements of 1006.4 Performance of system at the center of the manacfacturing floor Item 5 Please ideritify, on the drawings, the wiring methods, and the number and type of conductors. Item 6 Review and Approval of Plumbing Drawings and inspection of Plumbing installations are performed by the Franklin County Board of Health Item 7 The Washington Township Fire Marshal has requested an opportunity to provide input to the Dublin building department on issues relating to fire protection. The building official has evaluated the Fire Marshal's comments related to the fire protection provisions of the OBC and incorporates those comments, by reference, into this Phased Plan Approval and Correction Request. Please respond to the Fire Marshal 's contntents Tke followirtg itenis are required for code conipliarace, but are not necessarily covered ita detail in the corastructiori documents. This list is a remirider to tlte desigri professional and contractors of issues, which are to be satisfactorily dealt with in the fteld: Item A OBC 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the building official or the building official's designated representative. Item B OBC 105.7.2 Posting. The certificate of plan approval shall be posted in a conspicuous location outside of the building and in the front part of the premises on which is, or will be the approved building or equipment to which the approved plans relate. The owner and the contractor shall, so far as possible, preserve and keep the certificate posted until the completion of the work to which the approved plans relate. Item C OBC 106.4 Amended construction documents. If substantive changes to the building are contemplated after first document submission, or during construction, those changes must be NABuilding Standards\-Iarpham\Reviews 2008\08-200028 plcl Steemer Add.doc ADDITION to STANLEY STEEMER Permit No.: 08-20028 February 5, 2008 Page 3 of 3 submitted to the building official for review and approval prior to those changes being executed. The building official may waive this requirement in the instance of an emergency repair, or similar instance. Item D OBC 109.1 General. Construction or work for which an approval is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. This includes firestopping and draftstopping (Chapter 7 OBC), ntechanical work; piping, ducts and systems (Chapter 3 OMC), structural members and connectiorts (Chapter 16 OBC), and electrical rvork (Chapter 27 OBC). All systems arad elenierats covered by code are to be inspected and approvecl before beifig covered. Item E OBC 1103.1 Where required. Buildings and structures, temporary or permanent, including their associated sites and facilities, shall be accessible to persons with physical disabilities. OBC 1103.2.1 Specific requirements. Accessibility is required in buildings and facilities, or portions thereof, to the extent indicated in ADAAG Section 4.1 and this chapter. Item F All electrical will comply with the requirements of Article 27 OBC and the National Electrical Code, NFPA 70, OBC approved edition and is subject to the approval of the electrical field inspector. Please reply to this request for additional information with a letter indicating your response to each item of this request and that of the Washington Township's Fire Department comments, if applicable. Once the requested information is available, submit Three (3) comvlete sets of the additional information requested to the City of Dublin, Division of Building Standards for further review. TO REQUEST AN APPEAL HEARING, YOU MUST sent a written request, listing the items to be appealed and the relief sought and a copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 R ie ed and Signed, Ray M. arpham, AIA Jeffrey S. Tyler AIA Commercial Plans Examiner Chief Building Official Owner or Date Print Name and Title as Signed NABuilding Standards\I-Iarpham\Reviews 2008\08-200028 plcl Steemer Add.doc DATE: WASHINGTON TOWNSHIP FIRE DEPARTMENT 6200 Eiterman Roact, l?O. Box 3248 Dublin, Ohio 43016 614-652-3920 • Fax C 14-76C-25U7 r rF? ? C; Ty 0, °l'•?? January 30, 2008 TO: Jeffery S. Tyler, Director Division of Building Standards City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 ATTN: RE: PROJECT: APPLICATION No LOCATION RECEIVED: BUILD[NG CODE DATA: Use: Construction: Area: Occupancy: Notes: Mr. Harpham: Ray M. Harpham, Commercial Plans Examiner Washington Township's Fire Department Plan Review STANLEY STEEMER - NEW BUIIJDING ADDITION 08-200028 5700 Shier-Rings Road January 11, 2008 B/F-1, Office and Manufacturing. Q B, Noncombustible / Un-Protected [Existing & New Consuuction] 12,544 SF [Proposed Addition] 50,400 SF Total Building Area. 360 [Proposed Addition] 505 Total Building. Construct new slab-on-grade pre-engineered building addition, with new doors, minor plumbing and HVAC work with new electrical lighting and power requirements. The building addition is proposed to be provided with an automatic fire suppression system. We have reviewed the construction documents for the referenced application dated December 28, 2007, as submitted to the Division of Building Standards January 11, 2008, for matters of concem to the Washington Township Fire Department regarding rules relating to the 2007 Ohio Building Code (OBC) and the fire prevention and the Dublin Fire Code(DFC) based upon the 2000 International Fire Code. We are able to recommend approval of the plans submitted with the following conditions: OBC 106.1.1 Information on construction documents. Because the construction documents do not have enough information for a complete ptan review, this correction letter is a request for missing information and contains a review only of the items submitted. A complete review will be performed upon receipt of the required information. This mav resutt in additional items not contained in this correction letter; Section 106 OBC. a. Subn:it the following mrnimum information for our revie?v: Please describe what rype of "manufacturing" is to take place tivithin this proposed barilding addition. Please describe the process of the mant facturrng and%r any egtiipment needed to facilitate the manufacturing process. The electrical plan shows very little po?ver reqtrirements that we might expect to see for a inanufacttiring' process. Please elaborate further. Also, will any materials be stored in the Manufacturing' Room #100 of this new building addrtion. If so, please include the amounts of materials to be stored as well as 'how ' these items tivill be stored (on pallets, shrink-wrapped, on shelving, etc.) as well as how hiQh they will be stored. Will any motor vehicles containing gasoline be stored or parked within this new building condition? The plans show an existing over-head garage door located at the one Trustees Gene Bostic • Denise Franz King • Charles Kranstuber Fiscal Offieer Jo}•ce E. Robinson Chief Allan NX"oo WASHINGTON TOWNSHIP FIRE DEPARTMENT DATE: January 30, 2008 Permit 07-200028 Page 2 of 2 side-ivall of this room. Please submit any M.SDS inforniation.for any type of hazardous malerial.r proposed to be slored. Thank you for the opportunity to review the plans. We are pleased to make ourselves avaitable to the developer and designers for questions and the discussion of alternatives. WASHINGTON TOWNSHIP FIRE DEPARTMENT ?? Michael A. Boryca, Architect! ans Examiner (614) 488-4009 ? gx"? Alan Perkins, CFPS Fire Marshal S:\Plan Raiews\Washington Toµnship`,08•200028 f.wpl February 8, 2008 Mr. Christopher P. John Dublin Building Systems I; . 6233 Avery Road Dublin, OH 43016 Review Services 5800 Shier-Rings Road Dublin, OH 43016-1236 Re: StanleY Steemer Addition - 5700 Shier Rings Rd Permit Application #08-200028 Phone:614-410-4600 Fax:614-718-4346 www.dublin.oh.us Dear Chl'is: Plans submitted on January 11, 2008, for the above-referenced project have been reviewed for zoning compliance and are being returned to your attention for revision. The purpose of this letter is to summarize all revisions required for zoning compliance only. Please review the contents of this letter with all plan review comments indicated on the plan set labeled "Z/E." All revisions must be coordinated with any applicable plan review comments made separately by the Division of Building Standards, the Office of the City Engineer, and/or the Washington Township Fire Department. Please return all marked plans and attachments with vour resubmittal to expedite the next round of permit application ulan review. General Comments General revisions are required for the site and landscaping plan for this project. The building setback reduction approved by the Dublin Board of Zoning Appeals was for an 11'-0 reduction from 97'-0 to 86'-0. The site plan shows a reduction of 85'-4". Please revise the plans accordingly or contact Planner Abby Scott with an explanation for the increased reduction in the side yard. Abby can be reached at 410-4654. The March 2000 Real Estate Purchase Agreement between the City of Dublin and Bates Property Management established a new 50-foot building and 25-foot pavement setback for this site along the frontage of Emerald Parkway. (See attached copy of purchase agreement.) The proposed pavement addition to the north of the existing lot must be redesigned to meet the required 25-foot pavement setback. CDE Sheet 3 of 5- Site Staking Plan • See comments above regarding required setbacks for building and pavement additions. • Revise Site Data Table and Coded Notes as indicated. Add note that all new or relocated fencing is limited to black painted or vinyl coated .chain link fencing at a maximum height of 6'-0. Barbed wire fencing is prohibited. Add miscellaneous notes as indicated. DBS Sheet 1- Landscaping Plan (Comments by Zoning Inspector Dean Henderson) • Please diversify tree species as noted, using a minimum of three different species. Use salt tolerant trees along Emerald Parkway as shown. • Add note on plan: "3.5-feet minimum spacing on evergreen shrub screening." Please list pine species and condition. Please provide an evergreen tree staking and planting plan. Mr. Christopher John February 8, 2008 Page 2 Proposed relocated pine trees will not provide adequate screening of parking area. Please add 20 spruces tree as noted on plan. Relocate four deciduous trees to east driveway entrance. Adjust plant material as necessary. Provide `Van Accessible' signs where applicable. Please call if you have any questions or comments regarding these comments. I can be reached at 410-4664. Dean Henderson can address any landscape related questions and is available at 410-4646. The Review Services staff will be glad to meet with you or your design team to answer any questions concerning this review. Please let us lrnow if we can be of any assistance. Sincerely, x, 4/ 1 A,3? Ak`rv Dave Marshall Development Review Specialist DM/df S/Review Serv ices/Dave/2008/Stanley Stecmer 20808 Division of Engineering 5800 Shier-Rings Road CITY OF DUBLIPi Phone: 614-410-4600 Dublin, Ohio 43016-1236 Fax: 614-718-4346 To: James F. Olausen, P.E. - Civil Design Engineering, Inc. From: Kristin K. Yorko, P.E., Civil Engineer .?-_'? Date: February 5, 2008 Re: Stanley Steemer Project Number 08-001-COM We have reviewed the plan submission made by your office on January 11, 2008 for this project. Your office should also review the attached redlined prints as they support the following written comments: General Comments • The Site Improvement Plans will be required to be submitted on 22 by 34-inch 4-mil Mylars and in electronic format compatible with AutoCAD once final approval is given. Staking, Grading and Utility Plan (Page 3 of 5) • Show and label all existing and proposed right-of-ways, easements (including type) and no-build zones (Are they all shown? It seems like there should be ones along the eastern property line?) • Show and label all proposed and/or existing ingress/egress, or cross access easements (Cross access for tower site?) Typical cross-section of parking lot pavement and sidewalks & curbs Utility and Grading Plan (Page 4 of 5) • Existing utilities - dashed (water line service information) • Size, slope, and type of proposed and existing utility services and mains • Existing (dashed) and proposed (solid) storm sewers • Benchmark elevations, designations and locations • Storm sewer and sanitary sewer top of casting & invert elevations • Major flood routing • Size, type, and slope of ex. and proposed storm sewers [maybe done with profiles] • Orifice plate details • Headwall specifications Erosion Control Notes (Page 5 of 5) Sequence of construction (install tree fencing first) Stormwater Management • Please sealed and sign a copy for our files. If you have any questions regarding these comments, please contact us. N:\ENGINEERING\PERSONAL\KRISTIN\COMMERCIAL\94-008-COM ELEC. COM..DOC Page 1 of 1 r i August 6, 2008 UNIFIED RESPONSE LETTER (URL) Mr. Wally Patrick Sellers Electric Company, Inc. P.O. Box 347 Review Services Delaware, OH 43015 5800 Shier-Rings Road Dublin, OH 43016-1236 Re: Dublin Permit Application #08-200028 Rev. 4 Phone: 614-410-4600 Stanle Steemer Site Li htin y g g Fax:614-718-4346 www.dublin.oh.us Dear Mr. Patrick: 0-tice The City of Dublin's Review Services Team has completed review of materials submitted July 28, 2008, for your request far a Commercial Permit. At this time, the overall review status is disapproved and the building permit is denied. The outcome of each review is as follows: Ohio Building Code - no review required Dublin Fire Code - no review required Site Engineering Standards - no review required Zoning & Landscape - disapproval (plan review letter attached) Note the Building Plan Review Letter is not a Building Permit. Please provide a unified resubmittal responsive to the attached review letters consisting of three (3) updated and complete plan sets and the disapproved marked up check prints to our Building Permit Window, 5800 Shier-Rings Road. To facilitate review of your resubmittal, a written description of your responses to the itemized plan review letter comments (and other plan changes you may propose) is requested and recommended. I am available to handle general status and procedural questions. Technical questions pertaining to the plan review letters may be directed to the appropriate plan reviewer. Sincerely, , Steve A. Snyder, P.E. , Review Services Coordinator SAS/df Attachments ? I August 6, 2008 Mr. Wally Patrick Sellers Electric Company, Inc. P.O. Box 347 Review Services Delaware, OH 43015 5800 Shier-Rings Road Dublin, OH 43016-1236 Re: Stanley Steemer Site Lighting Phone:614-410-4600 Permit Application #08-200028 Fax: 614-718-4346 www.dublin.oh.us Dear Mr. Patrick: Site lighting plans submitted on July 28, 2008 for the Stanley Steemer building addition have been reviewed for zoning compliance and are being returned to your attention for revision. The purpose of this letter is to summarize all revisions required for zoning compliance only. All revisions must be coordinated with any applicable plan review comments made separately by the Division of Building Standards, the Office of the City Engineer, and/or the Washington Township Fire Department. Please return all marked plans and attachments with your resubmittal to exuedite the next round of permit application plan review. All new site and building exterior illumination for this site is now subject to the requirements of City of Dublin Code Section 153.149 Exterior Lighting Requirements (see attached.) The code revision was approved by City Council February 19, 2008 and went into effect thirty later. The standards and design requirements of the new code section will necessitate the following revisions to the proposed exterior site lighting plan: • An iso-candella or "point-by-point" lighting grid must be provided that demonstrates an average lighting range from one to three foot-candles or an "average to minimum" light level ratio of no more than 4:1. A second lighting grid must be provided confirming the estimated light trespass levels at 10'-0 beyond the property perimeter will be less than 1.0 foot-candle. • Light fixtures shall be no more than 20'-0 above grade measured from top of fixture to grade. (The proposed fixtures measure 22'-0 including a two foot concrete base.) Please note that the maximum allowable height for a concrete light pole base located in a parking (or service) area is now limited to a maximum height of thirty inches (30") above the finished pavement. • Pole-mounted fixtures at mounting heights of 20'-0 or less shall use no greater than 250 watt metal halide lamps. (The proposed fixtures 400 watt metal halide lamps.) r Mr. Wally Patrick August 6, 2008 Page 2 Please revise the lighting plans as indicated above and resubmit four copies of the site electric plan with base details, lighting grids, and light fixture cut sheets for review. If your client feels the lighting standards of Code Section 153.149 pose serious business operation or safety issues you may request a site safety exemption from the standards as defined in Section 153.149(D)(5) which reads in part..." Any use or site deemed necessary by the Chief of Police or his/her designee based on business operation or safety statistics may request from the Director of Land Use and Long Range Planning to be exempt from the requirements set forth in Section 153.149(3)(C)(3). Should your client decide to pursue this avenue please send the request for exemption to Steve Langworthy, Director of Land Use and Long Range Planning, 5800 Shier-Rings Rd, Dublin, OH 43016. Please copy me on the request letter if one is filed. Please feel free to call me at (614) 410-4664 if you have any questions or comments concerning this review. I will be glad to meet with you to review the comments listed above if it will help expedite the required revisions to and resubmittal of the permit sets. Sincerely, f riUG- //6/l??i6f2tzG Dave Marshall Development Review Specialist DM/df S/Review Services/Dave/2008/3tanley Steemer 80608