Loading...
07200991 Permit File CITY OF DUBLIN- July 10, 2008 Division of Building Standards Ann Gunzenhaeuser 5800 Shier-Rings Road Dublin, Ohio 43016-1236 M/I Financial Corp. 3 Easton Oval Phone: 614-410-4600 Columbus, Ohio 43219 Permit Phone: 614-4]D-4670 Fax: 614-761-6566 Automated Inspection RE: Permit Address: 5937 Vandeleur Place line: 614-410-4680 Web Site: www.dublin.oh.us Permit Number: 07-200991 Dear Ms. Gunzenhaeuser: The City of Dublin has issued a Certificate of Occupancy for the above-mentioned property. Any escrow amounts held may be released. If there are any questions, please feel free to contact me. Thank you. Sincerely, Jeffrey S. Tyler, CBO Director of Building Standards a CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 RESIDENTIAL OCCUPANCY PERMIT This is to certify that I have inspected the residence described below and approved it for occupancy. ADDRESS: ? aA fJ A3 T V QZ l PERMIT NO.: COW? BY. FINAL INSPECTION DATE: 3 Inspection Date AP DA Ins Comments Inspection Date AP DA Ins Comments Plumbing Insulation 0;-M APP - Underground Sewer „ 01 Footing 7 Final Electric Foundation Final /V ~uvri+J Nd1~ft?sif~~rq( Steel Plumbing 1 , Foundation 9A 5N Final HVAC II s1 cov„C-~g~~ l'vRcv~ w N - .C17 ''f k 2{,07 $/f Radon ? o7 p SEf- Final Gas Preslab Piping Rough x Engineering Electric' (CWA) Engineering (9 1 Electric (Pre-Sod) Service Final If 07 t'MH(, Rough Engineering 441P ~~D Plumbing -7 Gas Piping ~ A, Pry t4 7~ Z-Ce 7'~? (Rough). Rough HVAC Final Zoning Fireplace Zoning Rough Occupancy ~131 zz~ A Rtu Framing Division of Building Standards 5800 Shier Rings Road y t a_ n Dublin, Ohio 43016 Phone: WMD 614/410-4670 IC11TY OF DUBLIN Inspection Line: 614/410-4680 CONDITIONAL APPROVAL AGREEMENT This agreement made and entered into by and between 4Idas~ SE At xr (Project Manager/General Contractor) Herein after known. as the Project Manager /General Contractor, and (Ownerloccupant) Hereinafter- known as the OwnerlOccupant, and the City of Dublin, hereinafter known as the City, who mutually agree and covenant as follows: J . The Project Manager/General Contractor, who is constructing anew premises at: 5337 /'AN3L1~~.~L. Building Permit No. d7 ?:!9M , has applied for a Certificate of Occupancy. 2. The premises; as of-the date this agreement is signed, has not met all requirements of-the Dublin Codified Ordinances, hereinafter known as the Code, and therefore additional final. inspections cannot be approved. 3. The list of items, which is attached to and is a part .of the agreement, is accepted by both the Project Manager/General Contractor .and the .Owner/Occupant, documentation of those items necessary to be completed prior to the project receiving final approval. 4. Acknowledging that -the premises are not completed and that certain items, as shown, are requirements of the Code. of the City, the Owner/Occupant, requests that the City allows occupancy of the premises and use of the property as of the date of this agreement. 5. In return for such above Conditional Approval, the Project Manager/General Contractor agrees to complete all items as shown by (date) (4 L7 O and further agrees to release, hold harmless and indemnify the City and its agents, assigns and employees from. any and all obligation, liability, and/or responsibility that might arise as -a result of permitting occupancy under a Conditional Approval Agreement. 6. In return for the City allowing conditional approval, the Owner/Occupant hereby releases the City, its agent, assigns and employees from any and all obligations and/or responsibilities related to the completion of the premises, and further agrees to release .and hold harmless the City, its agents, assigns and "employees -from any-and-all liability-that-might-arise-as -a-result-of-occupancy--..of-the premises. Further, the Owner/Occupant accepts the responsibility for the completion of those items -shown as incomplete, and recognizes that the City may revoke the Conditional Approval \\DUSLTNDATA_PER_SERVER\PER\PER\THOMEW\OFFICBWP\DOCS\DOC\FORMS\CONDITIONAL OCCUPANCY 'REEMENT.doc I of 2 Updated 4-02 r• Agreement causing the premises to be vacated; and/or the City may initiate .legal action, if these items are not completed on a timely basis, and within the schedule contained in item S of this agreement. The Owner/Occupant agrees that the City or its agent shall have full access to the property to inspect, or at it's sole and exclusive discretion cause to be made any improvement necessary to bring any part of the premises into compliance with this Conditional Approval Agreement. 7. The Owner/Occupant and the Project Manager/General Contractor both agree that the City, by accepting this Agreement in allowing occupancy as of the date of this Agreement has in no way waived, forfeited or otherwise relinquished any rights and/or powers that it would have if this Agreement were not in effect. 8. The Owner/Occupant acknowledges that he is under no obligation whatsoever to enter into this Agreement, but that absent .this Agreement, Conditional Approval to use the property will not be granted. 9. This Conditional Approval Agreement will serve as the Temporary Occupancy Permit the Building Official may issue in. accordance with 4101:2-1-27(E) of the Ohio Administrative Code when the entire scope of the building work has not been completed, but the Building Official has determined the building can be" occupied safely. Project Manager/Gen Contractor Date Project Manager/General Contractor (Signature) (Please Print) \QA Owner/Occu "ant Date Owne r/Occupant (Signature) (Please Print F 7~ C ty of Dublin . Date '0/ \\DUBLINDATA PER SERVER\PER\PER\THOMEW\OFFICEIWP\DOCSID WORMSICONDITIONAL OCCUPANCY AGREEMENT.doc Page 2 of 2 Updated 4-02 CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 SUBCONTRACTOR DISCLOSURE General Contractor: m T ,p Application No.: 07- c; 0099 f Job Address: 3 V The General Contractor is required to furnish the folkowing.inforrnation regarding any contractor working at the above address prior to.issuance of a Certificate of Occupancy. All subcontractor registrations must be current through, the i ' ss'ua We of a Certificate of Occupancy, including insurat c ehd aN oppliicabl e. Slate Certifications. TYPE OF CNtRAT+OR DUBLIN REGISTRATION NO EXCAVATION* CONCRETE* fwd 37vS MASONRY STRUCTURAL* & ELECTRICAL* ,d PLUMBING* HVAC* INSULATION 2 ROOFING* 4, DRYWALL SIDING SANITARY SEWER* zis LANDSCAPING FIRE PROTECTION UNDERGROUND . FIRE ALARM FIRE SUPPRESSION PAINTING OTHER *MUST BE COMPLETED AND AVAILABLE AT TIME OF FRAMING INSPECTION AND A COPY AVAILABLE FOR THE INSPECTOR TO TAKE TO OFFICE. ExceVSubcontractor Disclosure Update 2003 CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Fax: (614) 761-6566 - Inspection Line: (614) 410-4680 DO NOT REMOVE THIS SHEET FROM SITE NOTICE OF INSPECTION Inspection Type Application # 7`! Date Z~ The undersigned inspectors checked your property at X737 P".0aa/ p(, for compliance with Building Code. Any violations listed below must be corrected within days. VIOLATIONS 1a&Q J•W MW A4 T175 /~1S ~7eA/ 00 .;~1 QUdTT l5 ~ 3~4~' o0 ? APPROVED ? DISAPPROVED By ~=ONDITIONAL CITY OF DUBLIN u Shier Rings Road Dublin, Ohio 43016 Division of Engineering Phone: V/TDD 614-410-4600 Inspection Line: 614410-4680 Fax: 614/761-6506 DO NOT REMOVE THIS SHEET FROM SITE ENGINEERING FINAL INSPECTION PLEASE PRINT ALL INFORMATION Applicant: !2~ me-% r Company: Site: 9a 7 V a-r1.CJ~i ~1~~. (Provide Detail Plot Plan of Lot) Lot No:_ rJ J g Application No: ( Subdivision: PLEASE • NOT MARK BELOW THIS LINE ? No Violationstinspection Approved 0 Violations/Disapproved Approved For Conditional Occupancy ? 1. Clean Curb & Gutter ?10. Adjust Manhole to grade (Sanitary/Storm) (Ord. 28-98, Sec. 97.38) ? 11. Rebuild Manhole Throat (Sanitary/Storm) ? 2. Improper Approach (Ord. 59-74, Sec. 51.04) (Ord. 12-89, Sec. 153.210(A)) ?12. Improper Grading ? 3. Adjust Water/Gas service box to grade (Ord. 7-75, Sec. 150.040) ? 4. Adjust Inlet to grade ?13. Clean Street/Clean Sidewalk 5. Erosion Control/Sod a30t-x (Ord. 7-75, Sec. 150.039(J)) (Ord. 40-98, Sec. 53.090 (G)) Sawa (O•R.C• 723.011) ? 6. Replace Damaged Asphalt ?14. Adjust Watch Valve to Grade (Ord. 35-74, Sec. 97.37 (A & B)) (Mainline/Fire Hydrant) ? 7. Handicap Ramp (Install/Replace) ?15. Install Grade Stakes (ADA Specification) (Policy 98-027) (Sec. 152.70) 6. Submit "As Built" Plot Plan ? 8. Replace Damaged Curb, 5 ft. Minimum Sections (Policy 98-027) (Ord. 7-75, Sec. 150.038(C)) ?17. Driveway Exceeds 8% Maximum Slope ? 9. Replace Damaged SidewalkBikepath (Policy 98-019) (Ord. 35-74, Sec. 51.04) .y~ -loco L118. Remove Erosion Control Measures Comments: A&'/'b Contact Building Division at 410-4680 for re-inspection when work has been completed. The Engineering Final Inspection m st a rov prior t requesting an Occupancy Inspection by the Building Division. Inspector: Date: K0-- Re-Inspection: 0 Approved ? Disapproved ? Conditional Inspector: Date: Engineering Final Inspection WHITE - Site YELLOW - File E 304 rev. 12104 PP Inspection Type(s): ZONING INSPECTION FORM Zoning/Landscape Land Use and Long Range Planning Commercial ? Code Enforcement Residential Sign ? CITY OF DUBLIN 5800 Shier-Rings Road; Dublin OH 43016 Other ? TelephonePTDD 614-410-4600 Dublin Planning Fax 614-410-4747 Dublin Inspection Line 614-410-4680 Permit Project Address: Contact Person: Contact Phone: YES NO 1) Approved Landscape Plan & ROA YES NO 6) Si'glriU d as approved YES NO 2) Plans, Checklist & Permit on Site YES NO 7) PatiffgVatces-, number & striped YES NO 3) Lighting installed per plan YES NO 8) Handi--drspams properly signed ~/YES~ NO 4) Landscape installed per plan YES NO 9) PazkMgftlands 7 foot minimum S NO 5) Mechanicals screened per code YES NO 10) Meet residential appearance code Zoning Approved ? Zoning Conditionally Approved (See Comments) Zoning Disapproved (See Comments) ? Date of Inspection //b Inspected By COMMENTS r !1 1 J r 11 iv Zoning Inspection Form PLA-120 Date 08/12/04 r1h M/I FINANCIAL CORP. Jeffrey S. Tyler Director of Building Standards City of Dublin, Building Standards Division 5800 Shier Rings Rd. Dublin, OH 43017 RE: Address: 5937 Vandeleur Place, Dublin, OH 43016 Building Permit Number: Loan Number: 07-131063 Dear Mr. Tyler, We hereby agree that the escrowed funds in the amount of $3,500.00, as specified in the Approved for Conditional Occupancy" inspections and requirements for this property, will not be released until a final Certificate of Occupancy is issued by the City of Dublin. In the event such final Certificate of Occupancy Agreement is not issued within the time period specified in the Conditional Occupancy Agreement, the City of Dublin has the right to demand payment of the escrowed funds for the completion of the project. Sincerely, ajj~4 11 f ?-s O~ Ann Gun enhaeuser Date M/I Financial Corp. (614) 418-8807 Ins ection Date AP DA fns Plumbing Comments fns ction Date AP DA Ins insulation Comments undor round Sewer Footing Final Electric Foundation 21J~ / Steel Final Plumbing Foundation gA yj ~ '9{=`7 ; Final HVAC 114-'1 ct~j Co~„r-~~oP~ ~ Zcvt~c~1~ W N Radon p o7 P SEf - Nat Sff Preslab Final Gas Rough Piping Electric Engineering (CWA) Electric Engineering Service (Pre-Sod) Rough , Final I 07 rYW4 Plumbing jX~ Engineering Rfl~ 3C~GY7 Qc7tJp Sp4 Gas Piping 2~ s N (Rough) Rough HVAC < <n Final Zoning Fireplace 114 A /L of j gyp oning Rough ccupancy Framing PP( CITY OF DUBLIN CUSTOMER RECEIPT Batch ID: 12/03/07 01 Receipt no: 20040 Type SvcCd Description Amount 2007 200991 BP BUILDING PERMITS Qty 1.00 $300.00 M/I HOMES Tender detail CK Ref#: 4909 $300.00 Total tendered: $300.00 Total payment: $300.00 Trans date: 12/03/07 Time: 14:07:14 THANK YOU FOR YOUR PROMPT PAYMENT CITY OF DUBLIN 5800 Shier Rings Road 1 \ Dublin, Ohio 43016 Division of Engineering Phone: V/TDD 614-410-4600 Inspection Line: 614-410-4680 Fax: 614/761-6506 DO NOT REMOVE THIS SHEET FROM SITE ENGINEERING FINAL INSPECTION PLEASE PRINT ALL INFORMATION Applicant: ~IoM& Company: Site: 513:7 ~6134R ~ Uw E (Provide Detail Plot Plan of Lot) i j Lot No: 556 Application No: 7- 2[SD qq' Subdivision: [(Q lff "b-E- 7 i PLEASE NOT MARK BELOW THIS LINE o Violations/Inspection Approved ? Violations/Disapproved OI Approved For Conditional Occupancy ? 1. Clean Curb & Gutter ?10. Adjust Manhole to grade (Sanitary/Storm) (Ord. 28-98, Sec. 97.38) ? 11. Rebuild Manhole Throat (Sanitary/Storm) ? 2. Improper Approach (Ord. 59-74, Sec. 51.04) (Ord. 12-89, Sec. 153.210(A)) ?12. Improper Grading ? 3. Adjust Water/Gas service box to grade (Ord. 7-75, Sec. 150.040) ? 4. Adjust Inlet to grade ?13. Clean Street/Clean Sidewalk ? 5. Erosion Control/Sod or Seed (Ord. 7-75, Sec. 150.039(J)) (Ord. 40-98, Sec. 53.090 (G)) (O.R.C. 723.011) ? 6. Replace Damaged Asphalt ?14. Adjust Watch Valve to Grade (Ord. 35-74, Sec. 97.37 (A & B)) (Mainline/Fire Hydrant) ? 7. Handicap Ramp (Install/Replace) ?15. Install Grade Stakes (ADA Specification) (Policy 98-027) (Sec. 152.70) / X96. Submit "As Built" Plot Plan Oda 7-2-0$ ? 8. Replace Damaged Curb, 5 ft. Minimum Sections (Policy 98-027) Y (Ord. 7-75, Sec. 150.038(C)) ?17. Driveway Exceeds 8% Maximum Slope ? 9. Replace Damaged Sidewalk/Bikepath (Policy 98-019) (Ord. 35-74, Sec. 51.04) ?18. Remove Erosion Control Measures Comments: Contact Building Division at 410-4680 for re-inspection when work has been completed. The Engineering Final Inspection must be approved prior to requesting an Occupancy Inspection by the Building Division. Inspector. Date: 7- 2-0i3 T I" Re-inspection: ? Approved ? Disapproved ? Conditional Inspector: Date: Engineering Final Inspection WHITE - Site YELLOW - File E 304 rev. 12/04 PP 5750 Chandler Court g V E y p Westerville, OH 43082 E-Mail: hoyssinc@aol.com 2299-07-S Phone (614) 895-1922 +H y + Order No. Survey Fax (614) 895-1949 CO) Construction Fax (614) 895-9549 CI N CERTIFIED TO 2N50NIO P15 TIU COUNTY OF FMNKI-IN LENDER MIF P.B. 106 PG. 16 OR./D.B. PG. ~Lq ~p 06-18-08 12W BUYER SCALE 1"= 20' DATE 11-9-07 DRN 0 CH 9,820 ~r IA,~0, 1 Of NO. 555 9*~9. 0 13AU.ANTPW 51~C, I PUPON, OHIO ON t t t~ t 558 CONC pA110 \ 0 941.60'` \g 2 9 00 941.80 0 92 941.60 37.2' 9 20 941.80 ,n 559 ~ ' 2 5T0?'y o N STONE & Saco 6 Y 2.0' i 00 of ciJ t` 7.8' ,I o X0.4 9 a\ DO q0 CONCI:~T~ 0 RIVE O CONC~~ 940.10 22.2' 940.40 941,80 25' 131 f7G, INS 941,80 t 25,8' - 2 51CJ1 WOK 9A 940,10 65,40' 6 940,10 VAN MF UI\ I Imo/ \C~ ~ O' We hereby certify that the foregoing MORTGAGE LOCATION SURVEYwas prepared in accordance with Chapter 4733-38, Ohio Administrative Code, and is not a boundary survey pursuant to Chapter 4733-37, Ohio Administrative Code. This plat is prepared for mortgage loan and title purposes only and is not to be construed as having been prepared for the owner or for the use of the owner for any purposes. THIS PROPERTY IS LOCATED IN ' FLOOD ZONE X = J. HUY COMMUNITY PANEL 59049C 7313 PAGE 0108"6 DATE 82-95 13y"'6y,~RVE JAsubdivisiow\Baaa-eMS RESHOOT.dwg, 6/18/200810:58:29 AM CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 M/I HOMES OF CENTRAL OHIO, LLC 3 EASTON OVAL SUITE 310 . COLUMBUS, OH 43219 June 23, 2008 RE: Conditional Occupancy Approval Nearing Expiration Application Number: 07-200991. Address: 5937 VANDELEUR PL Project Description: SQ FT 5911 Subdivision/Lot BALLANTRAE 7 #558 Dear M/I HOMES OF CENTRAL OHIO, LLC: The Building Standards Division records indicate that the above-mentioned Conditional Occupancy Approval will expire on June 07, 2008 and that the project has not received a Certificate of Occupancy. In the event that we are in error, please contact this office immediately so that we may amend our files and issue the appropriate Certificate of Occupancy. If the project has not been completed or simply lacks final inspections, please call the Inspection Line (614-410-4680) to schedule the final inspections immediately. Make sure that paperwork is on the jobsite prior to the inspection. We look forward to hearing from you soon regarding the completion of this project. If we may be of further assistance, please feel free to call our office at (614) 410-4670. Sincerely, Jeffrey Tyler Chief Building Official 7 Znd9S/ • t DIVISION OEM sCIRYM MIN HOW. INC. 3 Easton Oval Suite 240 Columbus, Ohio 43219 (614) 418-8800 • Fax: (614) 418-8889 September 21, 2007 Mr. Brian O'Reilly Showcase Division M/I Schottenstein Homes, Inc. 3 Easton Oval, Suite 240 Columbus, OH 43219 RE: BT 558 Laurel t Brian: It is my understanding the (3) 1 %"x11 7/8" LVL header over the kitchen pass through for the above referenced project was cut 16" short of the side to side steel beam below. Both bearing points of the LVL now bear on the flush steel beam below. I have reviewed the loads in this area and have found the WIOxl5 flush steel beam is more than adequate. Please call should you have any questions, or if additional information is required. ehi rely Pierce tyect Cc: John Toppari John Blazer/File ALVIN # J Y PIERCE 8298 CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Date li~10-7 Application No. .?00 / 9 / trAPPLICATION FOR ELECTRICAL PERMIT Job Address 6_93-70 UA ~ 4EU Y' PIS(, CC Parcel No. Subdivision I~~,1~,anFfae Lot No. Owner Name ROB C44> I k HA *e S Telephone lJ v Contractor Name. ~k b DD A S e r::1 f Jr / C Telephone Contractor Address A) Dublin Registration No. 16 Residential: New Sq. Ft. Alteration/Addition Sq. Ft. Temporary Service $40.00 $40.00 Minimum plus $20.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Low Voltage Systems: Square Feet $40.00 Minimum plus $10.00 for each addidunal 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Commercial: New Sq. Ft. Alteration/Addition Sq. Ft. Temporary Service $60.00 $60.00 Minimum plus $60.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. and up to 50,999 Sq. Ft. (sizes above, See Fee Schedule) Low Voltage Systems: Square Feet $30.00 Minimum (plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.) 3% State of Ohio Surcharge (commercial only) Total $ JOB DESCRIPTION Rum This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of Dublin, all the laws of the State and the National Electric Code regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. Signature of licensed contractor or wner Division of Building Standards Date: 1/1/2001 CITY OF DUBLIN Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Application Number . . . . . 07-00200991 Date 9/12/07 Revision number . . . . . . . 1 Property Address . . . . . . 5937 VANDELEUR PL Parcel Number: 274-001170 Alternate Address: BALLANTRAE 7 #558 Tenant nbr, name . . . . . . SQ FT 5911 Application type description RES SINGLE FAMILY DETACHED Property owner . . . . . . . M/I Homes of Central Ohio,LLC Contractor . . . . . . . . . M/I HOMES OF CENTRAL OHIO, LLC Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 240.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/10/08 Qty Unit Charge Per Extension BASE.FEE 40.00 10.00 20.0000 RES ELECTRICAL SERVICE 200.00 Special Notes and Comments NOTICE TO APPLICANT SEPARATE OWNER/CIVIC ASSOCIATION REVIEW AND APPROVAL MAY BE REQUIRED BY DEED. APPLICANT IS RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE RESTRICTIVE COVENANTS AND DEED RESTRICTIONS REQUIRED BY TITLE. SIDEWALKS REQUIRED Contact ENGINEERING to coordinate 614-410-4624 PROTECT LANDSCAPING as per Dublin's Landscape Inspector at (614) 410-4660. STREET TREES REQUIRED CONTACT PAULA CHOPE, CITY FORESTER Call 410-4701 PRIOR to ORDERING AND INSTALLING for tree placement A Minimum of THREE, 2-1/2 Inch Caliper DECIDUOUS TREES are required in the front yard of this lot, No Closer than SEVEN FEET to a Side Property Line. YARD TREES are to be chosen from the species listed on the City of Dublin approved Street Tree List. Installation will occur during the landscape phase of this house. Placement of the THREE TREES will be Field-Verified by The City PRIOR to INSTALLATION. CORNER and THROUGH LOTS Shall Meet This requirement on all street frontages. Air conditioning units are NOT PERMITTED within REQUIRED Side or Rear yards. Screen ALL Mechanical Units & Service Structures to top of This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 07-00200991 Date 9/12/07 Revision number . . . . . . . 1 Special Notes and Comments unit including utility features and air conditioning units. Contact PLANNING DIVISION 410-4600 DIMENSIONAL SHINGLES REQUIRED. WINDOW TRIM REQUIRED TO BE WOOD PER BALLANTRAE TEXT. DIMENSIONAL SHINGLES REQUIRED. POST LIGHT at DRIVEWAY with PHOTO CELL REQUIRED. Fee summary Charged Paid Credited Due Permit Fee Total 240.00 .00 .00 240.00 Plan Check Total .00 .00 .00 .00 Grand Total 240.00 .00 .00 240.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier - Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number: 7,7_001N SURVEYOR BUILDING LOCATION AND FIRST FLOOR ELEVATION CERTIFICATION FORM I, the undersigned, do hereby certify the following location of building and elevation of top of the foundation wall at the referenced property. It is the builder's responsibility to insure that the location and elevation of the top of the foundation wall plus the first floor system, as per the approved prints, comply with the site plan approved by the City of Dublin (in reference to the City of Dublin Codified Ordinance 1305.02(k)). Property Owner: SHOWCASE HOMES Subdivision: BALLANTRAE SEC. 7 Lot Number: 558 Address: 5937 VANDELEUR PLACE Approved Foundation Elevation 942.8 Feet above mean sea level. Actual Top of Foundation 942.88 Feet above mean sea level. STEVEtI Professional Seal: 7313 Signature of Surveyor: 8/2/2007 Date This form is to be completed prior to the foundation inspection and must be made available on-site with the approved prints. 7- S'- 07 INTERNATIONAL ENERGY CODE COMPLIANCE ADDENDUM DATE: 1/3/2006 FROM: CORNERSTONE ENERGY RE: DUCT INSULATION IN UNCONDITIONED AREAS We have communicated with Dublin Building Department and the municipality has explained to us they will be enforcing ductwork outside the conditioned en. elope to be insulated at R-8 starting immediately. Please attach this page to your current IECC's for code submittals. Unconditioned Ducts: - All ductwork located outside the conditioned building envelope will be insulated to R-8. Co *10 one Enerrlcce Chris Patterson Estimator Energy Star Rater Office: 614-351-1439 Ext. 228 Fax: 614-351-6650 N ex t el: 614-554-8644 136* 41 * 6831 Email: chris.patterson@nstalled.net lFoundation's4lErnmy- eeiwFae3 ~kea? *we areuNO us ENERGY CODE INSPECTION CHECKLIST Date: June 15, 2005 Rating No.: Building Name: Laurel Rating Org.: Foundations 4 Energy Owners Name: Laurel Homeowner Phone No.: 614-891.4900 Property Various Raters Name: Chris Patterson Address: Various, OH Raters No.: 06-02 Builders Name: Showcase Homes Weather Site: Delaware, OH Rating Type: Based On Plans File Name: Laurel Sunroom.blg Rating Date: Building Information: Conditioned Area (sq ft): 7699 Conditioned Volume (cubic ft): 62400 Insulated Shell Area (sq ft): 13055 The items below will be inspected for energy code certification. Any deviation from these specifications should be brought to the attention of Chris Patterson, as soon as possible to assure that the project will still comply with energy code requirements. Ceilings: [ ] 1. Attic: R30 Attc (2x4 24oc) (3038 s.f.) R-19.0 continuous insulation, R-11.0 cavity insulation. Name: Main Installation Quality: P A G Face / Inset Comments/Location [ ] 2. Vaulted: R30 Vault (2x4 24oc) (607 s.f.) R-19.0 continuous insulation, R-11.0 cavity insulation. Name: Vaulted Installation Quality: P A G Face / Inset Comments/Location Above-Grade Walls: _ [ ] 1. Wall: R13 (2x416oc) (3021 s.f.), Between conditioned space and ambient R-0.0 continuous insulation, R-13.0 cavity insulation. Name: 1st/2nd Flr Installation Quality: P A G Face / Inset Comments/Location REM/Rate - Residential Energy Analysis and Rating Software 01.41 This information does not constitute any warranty of energy cost or savings. 01985-2004 Architectural Energy Corporation, Boulder, Colorado. ENERGY CODE INSPECTION CHECKLIST Laurel Page 2 2. Wall: R13 (2x416oc) (344 s.f.), Between conditioned space and garage R-0.0 continuous insulation, R-13.0 cavity insulation. Name: Buffered Installation Quality: P A G Face / Inset Comments/Location Windows and Skylights: Window-to-Wall Area Ratio: 0.22 [ ] 1. Window: U-0.36 SHG-0.43 (201 s.f., West), U-Value: 0.360, SHGC: 0.430 For windows without labeled U-factors, describe features: Name: Front Orientation: West Comments/Location [ ] 2. Window: U-0.36 SHG-0.43 (160 s.f., South), U-Value: 0.360, SHGC: 0.430 For windows without labeled U-factors, describe features: Name: Right Orientation: South Comments/Location [ ] 3. Window: U-0.36 SHG-0.43 (228 s.f., East), U-Value: 0.360, SHGC: 0.430 For windows without labeled U-factors, describe features: Name: Rear Orientation: East Comments/Location [ ] 4. Window: U-0.36 SHG-0.43 (145 s.f., North), U-Value: 0.360, SHGC: 0.430 For windows without labeled U -factors, describe features: Name: Left Orientation: North Comments/Location [ ] 5. Window: U-0.50 SHG-0.50 (9 s.f., North), U-Value: 0.500, SHGC: 0.500 For windows without labeled U-factors, describe features: Name: Bsmt Orientation: North Comments/Location [ ] 6. Window: U-0.50 SHG-0.50 (9 s.f., South), U-Value: 0.500, SHGC: 0.500 For windows without labeled U-factors, describe features: REM/Rate - Residential Energy Analysis and Rating Software v11.41 This information does not constitute any warranty of energy cost or savings. ®1985-2004 Architectural Energy Corporation, Boulder, Colorado. ENERGY CODE INSPECTION CHECKLIST Laurel Page 3 Name: Bsmt Orientation: South Commentsli-ocation [ j 7. Skylight: U-0.36 SHG-0.43 (18 s.f.), U-Value: 0.360, SHGC: 0.430 For skylights without labeled U-factors, describe features: Name: Skylight Orientation: North Comments/Location Doors.. [ ] 1. Door. Steel-urth w/brk (22 s.f.), R-Value 4.4 Comments/Location [ ] 2. Door: Steel-urth w/brk (19 s.f.), R-Value 4.4 Comments/Location Frame Floors: [ ] 1. Floor: R19 (2x10 16oc) (279 s.f.), Between conditioned space and garage R-0.0 continuous insulation, R-19.0 cavity insulation. Name: Cant.#1 Installation Quality: P A G Face / Inset Comments/Location [ ] 2. Floor: R19 (2xl016oc) (90 s.f.), Between conditioned space and ambient conditions R-0.0 continuous insulation, R-19.0 cavity insulation. Name: Cant.#2 Rear Installation Quality: P A G Face / Inset Comments/Location Foundation Walls: [ ] 1. Wall: R5 813 GrdeDown (1818 s.f.), Between conditioned space and ambient/ground R-0.0 interior continuous insulation, R-0.0 interior cavity insulation, R-5.0 exterior insulation. Name: Basement Installation Quality: P A G Face / Inset Comments/Location 2. Wall: R5 813 GrdeDown (331 s.f.), Between conditioned space and garage/ground R-0.0 interior continuous insulation, R-0.0 interior cavity insulation, R-5.0 exterior insulation. REM/Rate - Residential Energy Analysis and Rating Software v11.41 This Information does not constitute any warranty of energy cost or savings. ®1985-2004 Architectural Energy Corporation, Boulder, Colorado. ENERGY CODE INSPECTION CHECKLIST Laurel Page 4 Name: Bsmt. Buffer Installation Quality: P A G Face ! Inset Comments/Location Slab Floors: [ J 1. Slab: Uninsulated (3186 s.f.) R-0.0 perimeter insulation, R-0.0 under slab insulation. Name: Basement Installation Quality: P A G Face / Inset Comments/Location Rim and Band Joists: [ ] 1. Joist: 1 st/2nd Fir (309 sJ.), Between conditioned space and ambient R-0.0 continuous insulation, R-13.0 cavity insulation. Name: 1 st/2nd Fir Installation Quality: P A G Face / Inset Commentsti-ocation [ 2. Joist: 1 st/2nd Buff (32 s.f.), Between conditioned space and garage R-0.0 continuous insulation, R-13.0 cavity insulation. Name: 1st/2nd Buff Installation Quality: P A G Face / Inset Comments/Location Mechanical Equipment: f ] 1. Heating: Fuekfired air distribution, Natural gas, 94.1 AFUE. Make and Model Number. [ ] 2. Cooling: Air conditioner, Electric, 10.0 SEER. Make and Model Number: [ ] 3. Water Heating: Conventional, Natural gas, 0.63 EF. Make and Model Number. Mechanical Ventilation System: [ ] Mechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Exhaust Only REM/Rate - Residential Energy Analysis and Rating Software v11.41 This Information does not constitute any warranty of energy cost or savings. ®1885-21)04 Architectural Energy Corporation, Boulder, Colorado. ENERGY CODE INSPECTION CHECKLIST Laurel Page 5 System description(make): Air Leakage Control: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be type IC rated and installed with no penetrations; or, installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [ ] Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R -values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in conditioned basement must be insulated to R-0.0. [ ] Ducts in conditioned basement must be insulated to R-0.0. [ ] Ducts installed in exterior wall assemblies shall have at least 2" of rigid foam insulation with foil facing installed between sheathing and duds. Duct Construction: [ ] All ducts must be sealed with mastic and fibrous backing tape. Pressure-sensitive tape may be used for fibrous ducts. Duct tape is not permitted. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. [ ] Programmable Thermostat Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 120 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. REM/Rate - Residential Energy Analysis and Rating Software v11.41 This Information does not constitute any warranty of energy cost or savings. ®1985-2004 Architectural Energy Corporation, Boulder, Colorado. ENERGY CODE INSPECTION CHECKLIST Laurel Page 6 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pine Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature (°l' Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum lnsuladon Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES REM/Rate - Residential Energy Analysis and Rating Software v11.41 This information does not constitute any warranty of energy cost or savings. ®1885-2004 Architectural Energy Corporation, Boulder, Colorado. 2004 IECC ANNUAL ENERGY COST COMPLIANCE Date: June 15, 2005 Rating No.: Building Name: Laurel Rating Org.: Foundations 4 Energy Owner's Name: Laurel Homeowner Phone No.: 614891-4500 Property Various Rater's Name: Chris Patterson Address: Various, OH Raters No.: 06-02 Builder's Name: Showcase Homes Weather Site: Delaware, OH Rating Type: Based On Plans File Name: Laurel Sunroom.blg Rating Date: Annual Energy Cost 2004 IECC As Designed Heating: 2101 1437 Cooling: 268 171 Water Heating: 296 252 Lights & Appliances: 400 421 Photovoltaics: 0 0 Service Charge: 102 102 Total: 3167 2383 " This home MEETS the annual energy cost requirements in accordance with Section 404 of the 2004 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 28.196. • Design energy cost is based on the following systems: Heating: Fuel-fired air distribution. 50.0 kBtuh, 94.1 AFUE. Cooling: Air conditioner, 36.0 kBtuh, 10.0 SEER. Water Heating: Conventional, Gas, 0.63 EF. Window-to-Wall Area Ratio: 0.22 Blower door test: Htg: 0.35 Clg: 0.18 ACHnat In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set to the "prevailing federal minimum standards" as of November, 2004. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REWRate - Residential Energy Analysis and Rating Software v11.41 This information does not constitute any warranty of energy cost or savings. ®1985-2004 Architectural Energy Corporation, Boulder, Colorado. RESPONSE ELECTRIC 2999 SWITZER "E PHONE/FAX 276-8228 COLUMBUS, OHIO 43219 PANEL SCHEDULE BRKR POS DESCRIPTION DESCRIPTION POS BRKR 40-AMP 1 220V 220V 2 30-AMP 2-POLE 3 WALL OVEN DRYER 4 2-POLE 40-AMP 5 AIR 220V 6 30-AMP 2-POLE 7 CONDITIONER COOKTOP 8 2-POLE 9 SPARE SPARE 10 11 SPARE SPARE 12 20-AMP 13 DINING ROOM FAMILY ROOM 14 20-AMP 20-AMP 15 DINETTE WASHER 16 20-AMP 20-AMP 17 MICROWAVE REFRIGERATOR 18 20-AMP 20-AMP 19 KITCHEN GFI BATH GFI 20 20-AMP 20-AMP 21 KITCHEN GFI WHIRLPOOL 22 20-AMP 15-AMP 23 FURNACE DISPOSAL 24 15-AMP 15-AMP 25 SUMP PUMP DISHWASHER 26 15-AMP 15-AMP 27 GARAGE GFI GDO OUTLET 28 15-AMP 15-AMP 29 SECURITY OUTLET GDO OUTLET 30 15-AMP 15-AMP 31 LIGHTING LIGHTING 32 15-AMP 15-AMP 33 LIGHTING LIGHTING 34 15-AMP 15-AMP 35 LIGHTING LIGHTING 36 15-AMP 15-AMP 37 LIGHTING LIGHTING 38 15-AMP 15-AMP 39 LIGHTING/SMOKEDET LIGHTING 40 15-AMP LOAD CALCULATION SHEET 3314 SQUARE FOOT @ 3 VA PER FOOT 9942 2 GARAGE DOOR OPENERS-1500VA 3000 4 SMALL APPLIANCE CIRCUITS -1500 VA 6000 2 LAUNDRY CIRCUITS-1500 VA 3000 SUMP PUMP 1500VA 1500 110V FURNACE -1500 VA 1500 REFRIGERATOR-1500 VA 1500 WHIRLPOOL-1500 VA 1500 DISPOSAL-1500 VA 1500 DISHWASHER -1500 VA 1500 GENERAL LIGHTING LOAD 30942 1ST 10 KVA @ 100 % OF LOAD VALUE 10000 VA REMAINING LOAD @ 40% 20942 8376.8 VA 220V COOKTOP 8000 VA 220V WALL OVEN 8000 VA HEAT PUMP/AIR CONDITIONING 8800 VA TOTAL LOAD 43176.8 VA 43176.8 VA / 240 VOLTS 179.9033333 AMPS 200 AMP SERVICE rnnaerson w. Kot t 1 b 1 g aJ4 1 ebJ p. J p 7 -.20 a ?4?t Anderson/Wikoff 360 W. Waterloo Canal Winchester Ohio, Oh 43110 Phone 614-834-1099 S/N# QL-080896-15326 Proposal To: Showcase homes Dublin, OH ROOM SUMMARY Winter Square Latent + Sens ble - Total Space Name BTUH Feet BTUH - Cool BTUH BTUH Tons C.F.M. Family 44,926.23 441 1,215.11 14,715.68 15,930.79 1.33 528 Hearth 3,699.58 180 787.86 3,006.87 3,794.74 0.32 125 KITCHEN 1,023.58 180 752.36 3,116.85 3,869.21 0.32 127 dINING 1,399.74 182 352.95 1,656.64 2,009.59 0.17 66 fOYER 3,436.13 56 764.82 2,418.26 3,183.08 0.27 105 dEN 1,157.21 169 349.16 1,564.74 11913.91 0.16 63 hALL 115.71 63 318.33 707.69 1,026.02 0.09 34 mASTER bED 1,275.30 240 369.82 1,641,84 2,011.66 0.17 66 mASTER bATH 1,267.48 160 337.24 1,938.19 2,275.42 0.19 75 LAUNDRY & Cl 501.41 156 336.31 1,562.21 1,898.51 0.16 63 Bonus Room 2,663.48 504 717.30 3,455.15 4,172.44 0.35 137 Bedroom #2 1,200.79 192 344.68 1,540.31 11885.00 0.16 61 Bedroom #3 973.35 156 336.31 1,404.22 1,740.52 0.15 57 Bedroom #4 1,059.79 168 339.10 1,435.45 1,774.55 0.15 58 Loft 126.28 84 319.55 866.94 1,186.49 0.10 40 Hall Bath 170.74 60 163.96 670.00 833.97 0.07 27 Bedroom#413at 129.11 40 159.31 630.53 789.84 0.07 25 ,rot is 65,125.91 3,031 7,964.17 42,331.57 50,295.75 4.19 1,655.4 Computed results should be treated as estimates only as the weather, 3uct & structure design may vary. Be sure and size systems based on there I.bility to meet both the sensible and latent heat requirements, not just :.he total btuh. 06/21/2007 08:57 614-241-2080 EDWARDS PAGE 02 park d BaAa&I Golf Comm=4 " cbitectuxal Review Committee plan Approval Notification Lot Number: 558 Section: 7 Dater 06/20/07 Address: $937 Yandeleur Place Budder. Showcase Homes plans for the above referenced Lot have been reviewed by the D Umtrae Architectural Review Committw for compliance with: ¦ Architectural Diversity Standard. ¦ Exterior MILtedals Usage ¦ F=ont Yard Set Back Requirements ¦ Site Plan Requirements plans are approved as submitted for the above referenced eICMente. ¦ No Further Approvals Required O Additional Approvals Required as Follows: Approval CerdW by: n p Charles P. Driscoll, Member plans reviewed by Atchltectuxal Review Committee mesa O P-awB&=* B&w& GOVC= , I.LC D JCe~ryJteeQ iLaadoq~ i ~jnats Sc dmbetger ¦ Cbados P. J aoa4 O"CoMMOMld ws LLC O 11fte~d Jioe, . d,FJ'o rk.4 Aas * L7 Brian Jrecr joaesy Arc hfowt CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 462-3865 (Franklin County) Application No. Q T • ZC7~ q '1 Date V '.21 b~ J~ ew ? Remodel esidential ? Commercial APPLICATION FOR PLUMBING PERMIT The undersigned hereby applies for a permit to do plumbing and an inspection of same at the following location in accord with Chapter 4101:2-51 of the Ohio Administrative Code, and all regulations of the Franklin County Board of Health. Job Address 3 MvcW c. V o, Pte 'C Parcel No. Subdivision/Project Name I~Pl,~A.-) AA A ~ Lot No. S S 8 Owner's Name ~Ow~o me Telephone TI g~ S &0 Z) Contractor's Name A CC V 0-Art2 P (v rn Y"~ N C Telephone S.2 b -d IS / Contractor's Address 7 S 9 5- f S c. Dublin Registration Number o7 --1 7 Does the sewer discharge into an individual sewage disposal system or sanitary sewer? Sat\j 1- 7m ~4 How far distant from any dwelling, well or cistern is the sewage tank? 10, p~ What is the size of the main drain? Of what materials do the vent pipes consist? Of what material does the house drain consist? 4J *INDICATE NAME OF CERTIFIED BACKFLOW TESTER INSTRUCTIONS This form must be properly filled out and returned to the office of the City of Dublin at least four days prior to the date of the FIRST INSPECTION, accompanied by a fee calculated upon the following basis: RESIDENTIAL COMMERCIAL Application for permit & first fixture $50.00 Application for permit & first fixture $60.00 3 Number of remaining fixtures X $10.00 = ~c• Number of remaining fixtures X $12.00 = $ Total Inspection Fee $390 Total Inspection Fee Re-inspection fee (based upon disapproved Inspection and collected by the Franklin County Board of Health ONLY) $45.00 Qt Qty- Qty. Air Admittance Valve Garbage Disposal I Showers r *Backfiow Preventers Hot Water Heater Sterilizers Bath Tubs Interceptor Sump Pump Bed Pan Washers Kitchen Sink Trap Primer Bidet Laundry Trays Urinal Chemical Sinks Lavatories Wash Fountain Dental Cuspidors Mop Sinks Washing Machine Dilution Sump Outside Faucets Water Closets Dish Washers Roof Drains Water Lines f Drinking Fountain Rough-in Openings for Future Water Storage Tank Floor Drains Sewage Ejectors Other Garage Catch Basin GRAND TOTAL 61 HOT WATER TANK RE LACE ENT FEE $35.00 Division of Building Standards c~.~ CITY OF DUBLIN • Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-0.0200991 Date 8/28/07 Revision number . . . . . 1 Property Address . . . . . . 5937 VANDELEUR PL Parcel Number: 274-001170 Alternate Address: BALLANTRAE 7 #558 Tenant nbr, name . . . . . . SQ FT 5911 Application type description. RES SINGLE FAMILY DETACHED Property owner . . . . . . . M/I Homes of Central Ohio,LLC Contractor . _-_------_--M/I-HOMES OF CENTRAL OHIO, LLC Permit . . . . . . PLUMBING PERMIT Additional desc . . Permit Fee . . . . 380.00 Plan Check Fee .00 Issue Date Valuation 0 Expiration Date . . 5/22/10 Qty Unit Charge Per Extension BASE FEE 50.00 33.00 10.0000 EA RES PLUMBING >1 FIXTURE 330.00 Special Notes and Comments NOTICE TO APPLICANT SEPARATE OWNER/CIVIC ASSOCIATION REVIEW AND APPROVAL MAY BE REQUIRED BY DEED. APPLICANT IS RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE RESTRICTIVE COVENANTS AND DEED RESTRICTIONS REQUIRED BY TITLE. SIDEWALKS REQUIRED Contact ENGINEERING to coordinate 614-410-4624 PROTECT LANDSCAPING as per Dublin's Landscape Inspector at (614) 410-4660. STREET TREES REQUIRED CONTACT PAULA CHOPE, CITY FORESTER Call 410-4701 PRIOR to ORDERING AND INSTALLING for tree placement A Minimum of THREE, 2-1/2 Inch Caliper DECIDUOUS TREES are required in the front yard of this lot, No Closer than SEVEN FEET to a Side Property Line. YARD TREES are to be chosen from the species listed on the City of Dublin approved Street Tree List. Installation will occur during the landscape phase of this house. Placement of the THREE TREES will be Field-Verified by The City PRIOR t'o INSTALLATION. CORNER and THROUGH LOTS Shall Meet This requirement on all street frontages. Air conditioning units are NOT PERMITTED within REQUIRED Side or Rear yards. Screen ALL Mechanical Units & Service Structures to top of This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 07-00200991 Date 8/28/07 Revision number . . . . . . . 1 Special Notes and Comments unit including utility features and air conditioning units. Contact PLANNING DIVISION 410-4600 DIMENSIONAL SHINGLES REQUIRED. WINDOW TRIM REQUIRED TO BE WOOD PER BALLANTRAE TEXT. DIMENSIONAL SHINGLES REQUIRED. POST LIGHT at DRIVEWAY with PHOTO CELL REQUIRED. Fee summary Charged Paid Credited Due Permit Fee Total 380.00 .00 .00 380.00 Plan Check Total .00 .00 .00 .00 Grand Total 380.00 .00 .00 380.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00200991 Date 7/23/07 Revision number . . . . . . . 1 Property Address . . . . . . 5937 VANDELEUR PL Parcel Number: 274-001170 Alternate Address: BALLANTRAE 7 #558 Tenant nbr, name . . . . . . SQ FT 5911 Application type description RES SINGLE FAMILY DETACHED Property owner . . . . . . . M/I Homes of Central Ohio,LLC Contractor . . . . . . . . . M/I HOMES OF CENTRAL OHIO, LLC Permit . . . . . . RESIDENTIAL BUILDING PERMIT Additional desc . . Permit Fee . . . . 540.00 Plan Check Fee .00 Issue Date . . . . '7.23-0-7 Valuation . . . . 0 Expiration Date . . 1/19/08 Qty Unit Charge Per Extension BASE FEE 140.00 10.00 40.0000 RES BLDG PLAN REVIEW 400.00 Permit . . . . . . RES HEATING, VENTILATING, A.C. Additional desc . . Permit Fee . . . . 250.00 Plan Check Fee .00 Issue Date . . Valuation 0 Expiration Date 1/19/08 Qty Unit Charge Per Extension BASE FEE 50.00 10.00 20.0000 RES HVAC 200.00 Permit . . . . . . LOW VOLTAGE ELECTRICAL PERMIT Additional desc . Permit Fee . . . . 140.00 Plan Check Fee .00 Issue Date . . Valuation . . . . 0 Expiration Date . . 1/19/08 Qty Unit Charge Per Extension BASE FEE 40.00 10.00 10.0000 RES ELECTRICAL LOW VOLTAGE 100.00 Permit . . . . . . GAS LINE PERMIT Additional desc . Permit Fee . . . . 70.00 Plan Check Fee .00 Issue Date Valuation . . 0 Expiration Date . . 1/19/08 Qty Unit Charge Per Extension This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 07-00200991 Date 7/23/07 Revision number . . . . . . . 1 Qty Unit Charge Per Extension BASE FEE 70.00 Permit . . . . . . WATER PERMIT Additional desc . . Permit Fee . . . . 1600.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/19/08 Qty Unit Charge Per Extension 1.00 1600.0000 EA WATER DUBLIN .75" WATER TAP 1600.00 Special Notes and Comments NOTICE TO APPLICANT SEPARATE OWNER/CIVIC ASSOCIATION REVIEW AND APPROVAL MAY BE REQUIRED BY DEED. APPLICANT IS RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE RESTRICTIVE COVENANTS AND DEED RESTRICTIONS REQUIRED BY TITLE. SIDEWALKS REQUIRED Contact ENGINEERING to coordinate 614-410-4624 PROTECT LANDSCAPING as per Dublin's Landscape Inspector at (614) 410-4660. STREET TREES REQUIRED CONTACT PAULA CHOPE, CITY FORESTER Call 410-4701 PRIOR to ORDERING AND INSTALLING for tree placement A Minimum of THREE, 2-1/2 Inch Caliper DECIDUOUS TREES are required in the front yard of this lot, No Closer than SEVEN FEET to a Side Property Line. YARD TREES are to be chosen from the species listed on the City of Dublin approved Street Tree List. Installation will occur during the landscape phase of this house. Placement of the THREE TREES will be Field-Verified by The City PRIOR to INSTALLATION. CORNER and THROUGH LOTS Shall Meet This requirement on all street frontages. Air conditioning units are NOT PERMITTED within REQUIRED Side or Rear yards. Screen ALL Mechanical Units & Service Structures to top of unit including utility features and air conditioning units. Contact PLANNING DIVISION 410-4600 DIMENSIONAL SHINGLES REQUIRED. WINDOW TRIM REQUIRED TO BE WOOD PER BALLANTRAE TEXT. This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Page 3 Application Number . . . . . 07-00200991 Date 7/23/07 Revision number . . . . . . . 1 Special Notes and Comments DIMENSIONAL SHINGLES REQUIRED. POST LIGHT at DRIVEWAY with PHOTO CELL REQUIRED. Other Fees . . . . . . . . . RES BLDG INSPECTION 550.00 RES CERTIFICATE OF OCC 30.00 SEWER DUBLIN 2000.00 SEWER COLUMBUS 3044.00 SEWER INSPECTION FEE 120.00 Fee summary Charged Paid Credited Due Permit Fee Total 2600.00 .00 .00 2600.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 5744.00 .00 .00 5744.00 Grand Total 8344.00 .00 .00 8344.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. APPLICATION FOR BUILDING PERMIT This form is provided by the Building Industry Association of Ohio as a public service. THE Builders PERMIT NUMBER O • 20 p C} G} Issued in Ohio Under Authority of PTUQ c ~ Auditors Taxing District 274 Parcel Number 001170 t Address of Property 5937 VANDELEUR PLACE JUL 02 2007 ow 0 Subdivision BALLANTRAE -7 Lot 558 arc 3~: t~i tee U++t0 !Iv -_O2PQQAT1 Q Applicants Name John Blazer Phone Number (614) 418-8831 Email Address jblazer@showcasehomes.com Fax Number (614) 418-8889 Owner's Name M/I Homes of Central Ohio, LLC Phone Number (614) 418-8831 DBA: Showcase Homes Address 3 Easton Oval #240 Columbus, Ohio 43219 Designer's Name M/I Homes of Central Ohio, LLC Phone Number a DBA: Showcase Homes (641) 418-8831 Q Address 3 Easton Oval #240 Columbus, Ohio 43219 Builder's Name M/I Homes of Central Ohio, LLC Phone Number (614) 418-8831 DBA: Showcase Homes Address 3 Easton Oval #240 Columbus, Ohio 43219 Builder's ID 4533 Type of Improvement New One-Family Residential Improvement Cost $325,000.00 Number of Bedrooms 4 Heating Fuel Natural Gas Number of Gas Appliances 5 Per Unit Number of Baths 3 full 1 half Sewage Disposal Public Garage Type Attached Building Height 31 Water Supply Public Number Car Garage 3 o Building Zoning Unfinished Basement 1935 IV/f> Lot Area 14,810 Finished Basement 0 Total % Occupied by Structure 19.22% Lower Level 0 Front Setback 26.0' 1st Floor 2078 a~ Rear Setback 60.65' 2nd Floor 1236 ( 0;' 3/ Right Setback 15.5 a 3rd Floor 0 Left Setback Other 18.57 0 Lot Width at Building Line 116.0' Garage 662 (4 aZ Deck/Screened In Porch 0 Zoning District PRD Gross Square Feet 5911 Existing Use of Property VACANT LOT Building Area at Ground Level 2847 7"0 Living Area 2958 Flood Plain ? YES ® NO 0 Z Excavator License Number Fee Schedule Plumbing License Number Initial Electric License Number Occupancy HVAC License Number Footage Fireplace License Number Zoning a 0 U This section only to be filled out if required by Jurisdiction. Alt/Addtn. The owner of this building and undersigned, do hereby covenant and agree to comply with all the laws of the Plan Exam p, State of Ohio and the ordinances of this jurisdiction, pertaining to building and buildings, and to construct the proposed building or structure or make the proposed change or alteration in accordance with the plans and Gas Piping a. specifications submitted herewith, and certify that the information and statements given on this application, 9:6 9 drawings and specifications are to ththeir knowl true and correct. Other Signature of Applican ~/21 /CE7 Total Date Received D to Received Date Received Date Approved Date Approved 7' S. o T Date Approved #7 23 -o i I CITY OF DUBLIN Division of Building Standards - nspectioniLlneR(614) 410-4680 Ohio 43016 Phone: (614) These drawings have been reviewed for and shall comply with the 2004 Edition of the Residential Code of Ohio. PLAN REVIEW CHECKLIST o "ago g 0 -0 Application No. ° C. a m E Date Reviewed a m 0 o a c a Plan Reviewer's Comments & Notes Reviewed By v z m ii a u, is 'a o Approved Disapproved o Z c C OBBC Model Energy Code MEC Check worksheet required Manual J/Electdc Loads Houses over 3,000 Sq. Ft. Ordinance Stair Risers & Treads 7 314" max. riser 10" min. treads and 6 8" headroom R303.6 Stairway Illumination R311 Handrails & Guards R312 Schedules Required on Plans; houses, additions and R303.1 Light & Ventilation Schedules sunrooms Figure 307.2 rR3 06Sanitation -Fixture Clearance 07 R308 Required Safety Glazing 1318" s. c. or 20 min. door and 518" gyp. Bd. Type 'k' on R309 Attached Garage Fire Separation all common walls per City Ordinance 5.7 sq. ft. (24' net hgt. 20" net width) max. window still R310 Bedroom Emergency Egress hgt. Of44'a.f.f. R311 Exits R311.4.2.1 Interior Doors Bath 2'4""x 68", habitable space 216"x 6'8"(min) R311.4.3 Landings Minimum X x 3' R311.2.2 Understair Protection 112" gyp. Bd. Type '7C' 8smt.lhallway/bedrooms wired to prime electric/battery R313 Smoke Detector Locations pack - uprnterconnected Ordinance Carbon Monoxide Detector utside sleeping areas R317 Foam plastic separation R401.4.1 Soil bearing capacity Use 1,500 psf R403 Footing/pier/pad size & location(s) R403.1.6 Foundation anchorage 112" anchor bolt Q 6'0" oc, 7" into masonry & concrete Stamped engineered foundation plan required for R404 Foundation wall sizes & reinforcements V1 houses and additions R405 Foundation drainage systems R406 Damproofing or waterproofing R502.3 Floor joist(s) allowable spans Lumber specifications required on drawings R502.5 Allowable girder spans Per Tables R502.5(1) & R502.5(2) R502.6 Bearing 112" for wood & steel/ 3" for masonry & concrete R502.11.4 Floor Trusses Engineered design required at Frame Inspection PLAN REVIEW CHECKLIST "a o d a ~ 3 d E JO- OC v °L c y a Plan Reviewer's Comments & Notes E o Z m a a 0 M 7 0 Z a > ~ R503 Floor sheathing R(402.2) Concrete floors on ground R 506 R602 Wood wall framing R602.7 Headers Tables 502.5(1) & R502.5(2) R602.10 Wall bracing R603 Steel wall framing R703.7 Masonry veneer Table 703.4 R802 Wood roof framing Show truss profiles on roof plan R802.3 Framing details Rafter ties, joist not perpendicular to rafters R802.4 Allowable ceiling joist spans R802.5 Allowable rafter spans R802.10 Roof trusses Stamped engineered roof trusses required at framing inspection R807.1 Attic access 2 "x 30" R1001 Masonry chimneys Spark arrestor with rain cap per City Ordinance R1002 Facto built chimneys Spark arrestor with rain ca R1003 Masonry fireplaces Table 1003.1 & Figure 1003.1 R1004 Factory built fireplaces R1005 Exterior air supply M1701 Combustion air 50 cubic per 1,000 btu/h R602.3.1 Stud size & spacing Table R602.3.1(2) Front & Back Form Revised 04/12/05 CITY. 01V DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (6:14) 410-4670 • inspection Line: (614) 410-4680 Revision Application RECEIVED J Revision Fee $ JAN 01 2008 BUILDINOF DUBLtNN Application Number Q-j_2 CITY Address \JqNpELF, Reason for Revision A22 Co - -Rq1T:? 63tk2~i) r epc E AT C = PCNNF-, "Note: All revisions must be clearly highlighted or clouded on all the revised plans and plot plans." Contact Name 13LAZ.-.P_ Contact Phone Number ( -~4 l=3 For office use only Revision is to be reviewed by: Building Division Planning/Zoning Division Engineering Division Major Revision Minor Revision Supplemental Information Updated 8-23--04