07200991 Permit File
CITY OF DUBLIN- July 10, 2008
Division of
Building Standards Ann Gunzenhaeuser
5800 Shier-Rings Road
Dublin, Ohio 43016-1236 M/I Financial Corp.
3 Easton Oval
Phone: 614-410-4600 Columbus, Ohio 43219
Permit Phone: 614-4]D-4670
Fax: 614-761-6566
Automated Inspection RE: Permit Address: 5937 Vandeleur Place
line: 614-410-4680
Web Site: www.dublin.oh.us Permit Number: 07-200991
Dear Ms. Gunzenhaeuser:
The City of Dublin has issued a Certificate of Occupancy for
the above-mentioned property. Any escrow amounts held
may be released.
If there are any questions, please feel free to contact me.
Thank you.
Sincerely,
Jeffrey S. Tyler, CBO
Director of Building Standards
a
CITY OF DUBLIN
Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016
Phone: (614) 410-4670 • Inspection Line: (614) 410-4680
RESIDENTIAL OCCUPANCY PERMIT
This is to certify that I have inspected the residence
described below and approved it for occupancy.
ADDRESS: ? aA fJ A3 T V QZ l PERMIT NO.: COW?
BY. FINAL INSPECTION DATE: 3
Inspection Date AP DA Ins Comments Inspection Date AP DA Ins Comments
Plumbing Insulation 0;-M APP -
Underground
Sewer „ 01
Footing 7 Final Electric
Foundation Final /V ~uvri+J Nd1~ft?sif~~rq(
Steel Plumbing 1 ,
Foundation 9A 5N Final HVAC II s1 cov„C-~g~~ l'vRcv~ w N
- .C17 ''f k 2{,07 $/f
Radon ? o7 p SEf- Final Gas
Preslab Piping
Rough x Engineering
Electric' (CWA)
Engineering (9 1
Electric (Pre-Sod)
Service Final If 07 t'MH(,
Rough Engineering 441P
~~D
Plumbing -7
Gas Piping ~ A, Pry t4 7~ Z-Ce 7'~?
(Rough).
Rough HVAC Final Zoning
Fireplace
Zoning Rough
Occupancy ~131 zz~ A Rtu
Framing
Division of Building Standards
5800 Shier Rings Road
y t a_ n Dublin, Ohio 43016
Phone: WMD 614/410-4670
IC11TY OF DUBLIN Inspection Line: 614/410-4680
CONDITIONAL APPROVAL AGREEMENT
This agreement made and entered into by and between 4Idas~ SE At xr
(Project Manager/General Contractor)
Herein after known. as the Project Manager /General Contractor, and
(Ownerloccupant)
Hereinafter- known as the OwnerlOccupant, and the City of Dublin, hereinafter known as the City, who
mutually agree and covenant as follows:
J . The Project Manager/General Contractor, who is constructing anew premises at:
5337 /'AN3L1~~.~L.
Building Permit No. d7 ?:!9M , has applied for a Certificate of Occupancy.
2. The premises; as of-the date this agreement is signed, has not met all requirements of-the Dublin
Codified Ordinances, hereinafter known as the Code, and therefore additional final. inspections
cannot be approved.
3. The list of items, which is attached to and is a part .of the agreement, is accepted by both the Project
Manager/General Contractor .and the .Owner/Occupant, documentation of those items necessary to
be completed prior to the project receiving final approval.
4. Acknowledging that -the premises are not completed and that certain items, as shown, are
requirements of the Code. of the City, the Owner/Occupant, requests that the City allows occupancy
of the premises and use of the property as of the date of this agreement.
5. In return for such above Conditional Approval, the Project Manager/General Contractor agrees to
complete all items as shown by (date) (4 L7 O and further agrees to release, hold
harmless and indemnify the City and its agents, assigns and employees from. any and all obligation,
liability, and/or responsibility that might arise as -a result of permitting occupancy under a
Conditional Approval Agreement.
6. In return for the City allowing conditional approval, the Owner/Occupant hereby releases the City,
its agent, assigns and employees from any and all obligations and/or responsibilities related to the
completion of the premises, and further agrees to release .and hold harmless the City, its agents,
assigns and "employees -from any-and-all liability-that-might-arise-as -a-result-of-occupancy--..of-the
premises. Further, the Owner/Occupant accepts the responsibility for the completion of those items
-shown as incomplete, and recognizes that the City may revoke the Conditional Approval
\\DUSLTNDATA_PER_SERVER\PER\PER\THOMEW\OFFICBWP\DOCS\DOC\FORMS\CONDITIONAL OCCUPANCY
'REEMENT.doc
I of 2 Updated 4-02
r•
Agreement causing the premises to be vacated; and/or the City may initiate .legal action, if these
items are not completed on a timely basis, and within the schedule contained in item S of this
agreement. The Owner/Occupant agrees that the City or its agent shall have full access to the
property to inspect, or at it's sole and exclusive discretion cause to be made any improvement
necessary to bring any part of the premises into compliance with this Conditional Approval
Agreement.
7. The Owner/Occupant and the Project Manager/General Contractor both agree that the City, by
accepting this Agreement in allowing occupancy as of the date of this Agreement has in no way
waived, forfeited or otherwise relinquished any rights and/or powers that it would have if this
Agreement were not in effect.
8. The Owner/Occupant acknowledges that he is under no obligation whatsoever to enter into this
Agreement, but that absent .this Agreement, Conditional Approval to use the property will not be
granted.
9. This Conditional Approval Agreement will serve as the Temporary Occupancy Permit the Building
Official may issue in. accordance with 4101:2-1-27(E) of the Ohio Administrative Code when the
entire scope of the building work has not been completed, but the Building Official has determined
the building can be" occupied safely.
Project Manager/Gen Contractor Date Project Manager/General Contractor (Signature)
(Please Print)
\QA
Owner/Occu "ant Date Owne
r/Occupant (Signature)
(Please Print
F 7~
C ty of Dublin . Date
'0/
\\DUBLINDATA PER SERVER\PER\PER\THOMEW\OFFICEIWP\DOCSID WORMSICONDITIONAL OCCUPANCY
AGREEMENT.doc
Page 2 of 2 Updated 4-02
CITY OF DUBLIN
Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016
Phone: (614) 410-4670 • Inspection Line: (614) 410-4680
SUBCONTRACTOR
DISCLOSURE
General Contractor: m T ,p
Application No.: 07- c; 0099 f
Job Address: 3 V
The General Contractor is required to furnish the folkowing.inforrnation regarding any
contractor working at the above address prior to.issuance of a Certificate of Occupancy.
All subcontractor registrations must be current through, the i '
ss'ua
We of a Certificate of
Occupancy, including insurat c ehd aN oppliicabl e. Slate Certifications.
TYPE OF CNtRAT+OR DUBLIN REGISTRATION NO
EXCAVATION*
CONCRETE* fwd 37vS
MASONRY
STRUCTURAL* &
ELECTRICAL* ,d
PLUMBING*
HVAC*
INSULATION 2
ROOFING* 4,
DRYWALL
SIDING
SANITARY SEWER*
zis
LANDSCAPING
FIRE PROTECTION
UNDERGROUND .
FIRE ALARM
FIRE SUPPRESSION
PAINTING
OTHER
*MUST BE COMPLETED AND AVAILABLE AT TIME OF FRAMING INSPECTION AND A
COPY AVAILABLE FOR THE INSPECTOR TO TAKE TO OFFICE.
ExceVSubcontractor Disclosure Update 2003
CITY OF DUBLIN
Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016
Phone: (614) 410-4670 - Fax: (614) 761-6566 - Inspection Line: (614) 410-4680
DO NOT REMOVE THIS SHEET FROM SITE
NOTICE OF INSPECTION
Inspection Type Application # 7`! Date Z~
The undersigned inspectors checked your property at X737 P".0aa/ p(,
for compliance with Building Code. Any violations listed below must be corrected within days.
VIOLATIONS
1a&Q J•W MW A4 T175
/~1S ~7eA/
00
.;~1 QUdTT l5 ~ 3~4~' o0
? APPROVED ? DISAPPROVED By
~=ONDITIONAL
CITY OF DUBLIN u Shier Rings Road
Dublin, Ohio 43016
Division of Engineering Phone: V/TDD 614-410-4600
Inspection Line: 614410-4680
Fax: 614/761-6506
DO NOT REMOVE THIS SHEET FROM SITE
ENGINEERING FINAL INSPECTION
PLEASE PRINT ALL INFORMATION
Applicant: !2~ me-%
r Company:
Site: 9a 7 V a-r1.CJ~i ~1~~.
(Provide Detail Plot Plan of Lot)
Lot No:_ rJ J g Application No: ( Subdivision:
PLEASE • NOT MARK BELOW THIS LINE
? No Violationstinspection Approved 0 Violations/Disapproved Approved For Conditional Occupancy
? 1. Clean Curb & Gutter ?10. Adjust Manhole to grade (Sanitary/Storm)
(Ord. 28-98, Sec. 97.38)
? 11. Rebuild Manhole Throat (Sanitary/Storm)
? 2. Improper Approach (Ord. 59-74, Sec. 51.04)
(Ord. 12-89, Sec. 153.210(A)) ?12. Improper Grading
? 3. Adjust Water/Gas service box to grade (Ord. 7-75, Sec. 150.040)
? 4. Adjust Inlet to grade ?13. Clean Street/Clean Sidewalk
5. Erosion Control/Sod a30t-x (Ord. 7-75, Sec. 150.039(J))
(Ord. 40-98, Sec. 53.090 (G)) Sawa (O•R.C• 723.011)
? 6. Replace Damaged Asphalt ?14. Adjust Watch Valve to Grade
(Ord. 35-74, Sec. 97.37 (A & B)) (Mainline/Fire Hydrant)
? 7. Handicap Ramp (Install/Replace) ?15. Install Grade Stakes
(ADA Specification) (Policy 98-027)
(Sec. 152.70)
6. Submit "As Built" Plot Plan
? 8. Replace Damaged Curb, 5 ft. Minimum Sections (Policy 98-027)
(Ord. 7-75, Sec. 150.038(C))
?17. Driveway Exceeds 8% Maximum Slope
? 9. Replace Damaged SidewalkBikepath (Policy 98-019)
(Ord. 35-74, Sec. 51.04)
.y~ -loco L118. Remove Erosion Control Measures
Comments: A&'/'b
Contact Building Division at 410-4680 for re-inspection when work has been completed. The Engineering Final
Inspection m st a rov prior t requesting an Occupancy Inspection by the Building Division.
Inspector: Date: K0--
Re-Inspection: 0 Approved ? Disapproved ? Conditional
Inspector: Date:
Engineering Final Inspection WHITE - Site YELLOW - File
E 304 rev. 12104 PP
Inspection Type(s):
ZONING INSPECTION FORM Zoning/Landscape
Land Use and Long Range Planning Commercial ?
Code Enforcement Residential
Sign ?
CITY OF DUBLIN 5800 Shier-Rings Road; Dublin OH 43016 Other ?
TelephonePTDD 614-410-4600 Dublin Planning Fax 614-410-4747 Dublin Inspection Line 614-410-4680
Permit
Project Address:
Contact Person:
Contact Phone:
YES NO 1) Approved Landscape Plan & ROA YES NO 6) Si'glriU d as approved
YES NO 2) Plans, Checklist & Permit on Site YES NO 7) PatiffgVatces-, number & striped
YES NO 3) Lighting installed per plan YES NO 8) Handi--drspams properly signed
~/YES~ NO 4) Landscape installed per plan YES NO 9) PazkMgftlands 7 foot minimum
S NO 5) Mechanicals screened per code YES NO 10) Meet residential appearance code
Zoning Approved ?
Zoning Conditionally Approved (See Comments)
Zoning Disapproved (See Comments) ?
Date of Inspection //b Inspected By
COMMENTS
r
!1 1 J
r
11 iv
Zoning Inspection Form PLA-120 Date 08/12/04
r1h
M/I FINANCIAL CORP.
Jeffrey S. Tyler
Director of Building Standards
City of Dublin, Building Standards Division
5800 Shier Rings Rd.
Dublin, OH 43017
RE: Address: 5937 Vandeleur Place, Dublin, OH 43016
Building Permit Number:
Loan Number: 07-131063
Dear Mr. Tyler,
We hereby agree that the escrowed funds in the amount of $3,500.00, as specified in the
Approved for Conditional Occupancy" inspections and requirements for this property, will not
be released until a final Certificate of Occupancy is issued by the City of Dublin.
In the event such final Certificate of Occupancy Agreement is not issued within the time period
specified in the Conditional Occupancy Agreement, the City of Dublin has the right to demand
payment of the escrowed funds for the completion of the project.
Sincerely,
ajj~4 11 f ?-s O~
Ann Gun enhaeuser Date
M/I Financial Corp.
(614) 418-8807
Ins ection Date AP DA fns
Plumbing Comments fns ction Date AP DA Ins
insulation Comments
undor round
Sewer
Footing
Final Electric
Foundation 21J~ /
Steel Final
Plumbing
Foundation gA yj ~
'9{=`7 ; Final HVAC 114-'1 ct~j Co~„r-~~oP~ ~ Zcvt~c~1~ W N
Radon p o7 P SEf - Nat Sff
Preslab Final Gas
Rough Piping
Electric Engineering
(CWA)
Electric Engineering
Service (Pre-Sod)
Rough , Final I 07 rYW4
Plumbing jX~ Engineering Rfl~ 3C~GY7 Qc7tJp Sp4
Gas Piping 2~ s N
(Rough)
Rough HVAC < <n
Final Zoning
Fireplace 114 A /L of j gyp
oning Rough
ccupancy
Framing PP(
CITY OF DUBLIN
CUSTOMER RECEIPT
Batch ID: 12/03/07 01 Receipt no: 20040
Type SvcCd Description Amount
2007 200991 BP BUILDING PERMITS
Qty 1.00 $300.00
M/I HOMES
Tender detail
CK Ref#: 4909 $300.00
Total tendered: $300.00
Total payment: $300.00
Trans date: 12/03/07 Time: 14:07:14
THANK YOU FOR YOUR PROMPT PAYMENT
CITY OF DUBLIN 5800 Shier Rings Road
1 \ Dublin, Ohio 43016
Division of Engineering Phone: V/TDD 614-410-4600
Inspection Line: 614-410-4680
Fax: 614/761-6506
DO NOT REMOVE THIS SHEET FROM SITE
ENGINEERING FINAL INSPECTION
PLEASE PRINT ALL INFORMATION
Applicant: ~IoM& Company:
Site: 513:7 ~6134R ~ Uw E
(Provide Detail Plot Plan of Lot)
i
j Lot No: 556 Application No: 7- 2[SD qq' Subdivision: [(Q lff "b-E- 7
i
PLEASE NOT MARK BELOW THIS LINE
o Violations/Inspection Approved ? Violations/Disapproved OI Approved For Conditional Occupancy
? 1. Clean Curb & Gutter ?10. Adjust Manhole to grade (Sanitary/Storm)
(Ord. 28-98, Sec. 97.38)
? 11. Rebuild Manhole Throat (Sanitary/Storm)
? 2. Improper Approach (Ord. 59-74, Sec. 51.04)
(Ord. 12-89, Sec. 153.210(A)) ?12. Improper Grading
? 3. Adjust Water/Gas service box to grade (Ord. 7-75, Sec. 150.040)
? 4. Adjust Inlet to grade ?13. Clean Street/Clean Sidewalk
? 5. Erosion Control/Sod or Seed (Ord. 7-75, Sec. 150.039(J))
(Ord. 40-98, Sec. 53.090 (G)) (O.R.C. 723.011)
? 6. Replace Damaged Asphalt ?14. Adjust Watch Valve to Grade
(Ord. 35-74, Sec. 97.37 (A & B)) (Mainline/Fire Hydrant)
? 7. Handicap Ramp (Install/Replace) ?15. Install Grade Stakes
(ADA Specification) (Policy 98-027)
(Sec. 152.70) /
X96. Submit "As Built" Plot Plan Oda 7-2-0$
? 8. Replace Damaged Curb, 5 ft. Minimum Sections (Policy 98-027) Y
(Ord. 7-75, Sec. 150.038(C))
?17. Driveway Exceeds 8% Maximum Slope
? 9. Replace Damaged Sidewalk/Bikepath (Policy 98-019)
(Ord. 35-74, Sec. 51.04)
?18. Remove Erosion Control Measures
Comments:
Contact Building Division at 410-4680 for re-inspection when work has been completed. The Engineering Final
Inspection must be approved prior to requesting an Occupancy Inspection by the Building Division.
Inspector.
Date: 7- 2-0i3
T I"
Re-inspection: ? Approved ? Disapproved ? Conditional
Inspector: Date:
Engineering Final Inspection WHITE - Site YELLOW - File E 304 rev. 12/04 PP
5750 Chandler Court g V E y p
Westerville, OH 43082
E-Mail: hoyssinc@aol.com 2299-07-S
Phone (614) 895-1922 +H y + Order No.
Survey Fax (614) 895-1949 CO)
Construction Fax (614) 895-9549
CI N
CERTIFIED TO 2N50NIO P15 TIU COUNTY OF FMNKI-IN
LENDER MIF P.B. 106 PG. 16 OR./D.B. PG.
~Lq ~p 06-18-08 12W
BUYER
SCALE 1"= 20' DATE 11-9-07 DRN 0 CH
9,820
~r
IA,~0, 1 Of NO. 555
9*~9. 0 13AU.ANTPW 51~C, I
PUPON, OHIO
ON
t
t
t~
t
558
CONC pA110 \ 0
941.60'` \g 2 9 00
941.80 0
92
941.60 37.2' 9 20
941.80 ,n
559 ~ '
2 5T0?'y
o
N STONE & Saco
6 Y 2.0'
i 00
of ciJ t`
7.8' ,I o X0.4 9 a\ DO
q0
CONCI:~T~ 0
RIVE O CONC~~
940.10 22.2'
940.40
941,80 25' 131 f7G, INS
941,80
t
25,8' -
2 51CJ1 WOK
9A
940,10 65,40' 6
940,10 VAN MF UI\ I Imo/ \C~ ~ O'
We hereby certify that the foregoing MORTGAGE LOCATION SURVEYwas prepared in accordance with Chapter 4733-38, Ohio
Administrative Code, and is not a boundary survey pursuant to Chapter 4733-37, Ohio Administrative Code. This plat is prepared for mortgage
loan and title purposes only and is not to be construed as having been prepared for the owner or for the use of the owner for any purposes.
THIS PROPERTY IS LOCATED IN
'
FLOOD ZONE X = J.
HUY
COMMUNITY PANEL 59049C 7313
PAGE 0108"6 DATE 82-95 13y"'6y,~RVE
JAsubdivisiow\Baaa-eMS RESHOOT.dwg, 6/18/200810:58:29 AM
CITY OF DUBLIN
Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016
Phone: (614) 410-4670 - Inspection Line: (614) 410-4680
M/I HOMES OF CENTRAL OHIO, LLC
3 EASTON OVAL SUITE 310 .
COLUMBUS, OH 43219
June 23, 2008
RE: Conditional Occupancy Approval Nearing Expiration
Application Number: 07-200991.
Address: 5937 VANDELEUR PL
Project Description: SQ FT 5911
Subdivision/Lot BALLANTRAE 7 #558
Dear M/I HOMES OF CENTRAL OHIO, LLC:
The Building Standards Division records indicate that the above-mentioned Conditional
Occupancy Approval will expire on June 07, 2008 and that the project has not received a
Certificate of Occupancy.
In the event that we are in error, please contact this office immediately so that we may
amend our files and issue the appropriate Certificate of Occupancy.
If the project has not been completed or simply lacks final inspections, please call the
Inspection Line (614-410-4680) to schedule the final inspections immediately. Make sure
that paperwork is on the jobsite prior to the inspection.
We look forward to hearing from you soon regarding the completion of this project. If we
may be of further assistance, please feel free to call our office at (614) 410-4670.
Sincerely,
Jeffrey Tyler
Chief Building Official
7 Znd9S/
•
t DIVISION OEM sCIRYM MIN HOW. INC.
3 Easton Oval
Suite 240
Columbus, Ohio 43219
(614) 418-8800 • Fax: (614) 418-8889
September 21, 2007
Mr. Brian O'Reilly
Showcase Division
M/I Schottenstein Homes, Inc.
3 Easton Oval, Suite 240
Columbus, OH 43219
RE: BT 558
Laurel
t
Brian:
It is my understanding the (3) 1 %"x11 7/8" LVL header over the kitchen pass through for the
above referenced project was cut 16" short of the side to side steel beam below. Both bearing
points of the LVL now bear on the flush steel beam below.
I have reviewed the loads in this area and have found the WIOxl5 flush steel beam is more than
adequate.
Please call should you have any questions, or if additional information is required.
ehi rely
Pierce
tyect
Cc: John Toppari
John Blazer/File
ALVIN
# J Y
PIERCE
8298
CITY OF DUBLIN
Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016
Phone: (614) 410-4670 • Inspection Line: (614) 410-4680
Date li~10-7
Application No. .?00 / 9 /
trAPPLICATION FOR ELECTRICAL PERMIT
Job Address 6_93-70 UA ~ 4EU Y' PIS(, CC Parcel No.
Subdivision I~~,1~,anFfae Lot No.
Owner Name ROB C44> I k HA *e S Telephone lJ v
Contractor Name. ~k b DD A S e r::1 f Jr / C Telephone
Contractor Address A) Dublin Registration No. 16
Residential:
New Sq. Ft. Alteration/Addition Sq. Ft.
Temporary Service $40.00
$40.00 Minimum plus $20.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft.
Low Voltage Systems: Square Feet
$40.00 Minimum plus $10.00 for each addidunal 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft.
Commercial:
New Sq. Ft. Alteration/Addition Sq. Ft.
Temporary Service $60.00
$60.00 Minimum plus $60.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.
and up to 50,999 Sq. Ft. (sizes above, See Fee Schedule)
Low Voltage Systems: Square Feet
$30.00 Minimum (plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.)
3% State of Ohio Surcharge (commercial only)
Total $
JOB DESCRIPTION Rum
This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of
Dublin, all the laws of the State and the National Electric Code regulating construction, installation, repair and alteration,
and may be revoked at any time upon violation of any provisions of said laws.
Signature of licensed contractor or wner
Division of Building Standards
Date: 1/1/2001
CITY OF DUBLIN
Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016
Phone: (614) 410-4670 - Inspection Line: (614) 410-4680
Application Number . . . . . 07-00200991 Date 9/12/07
Revision number . . . . . . . 1
Property Address . . . . . . 5937 VANDELEUR PL
Parcel Number: 274-001170
Alternate Address: BALLANTRAE 7 #558
Tenant nbr, name . . . . . . SQ FT 5911
Application type description RES SINGLE FAMILY DETACHED
Property owner . . . . . . . M/I Homes of Central Ohio,LLC
Contractor . . . . . . . . . M/I HOMES OF CENTRAL OHIO, LLC
Permit . . . . . . ELECTRICAL PERMIT
Additional desc . .
Permit Fee . . . . 240.00 Plan Check Fee .00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 3/10/08
Qty Unit Charge Per Extension
BASE.FEE 40.00
10.00 20.0000 RES ELECTRICAL SERVICE 200.00
Special Notes and Comments
NOTICE TO APPLICANT
SEPARATE OWNER/CIVIC ASSOCIATION REVIEW AND APPROVAL MAY BE
REQUIRED BY DEED. APPLICANT IS RESPONSIBLE FOR COMPLIANCE
WITH ALL APPLICABLE RESTRICTIVE COVENANTS AND DEED
RESTRICTIONS REQUIRED BY TITLE.
SIDEWALKS REQUIRED
Contact ENGINEERING to coordinate 614-410-4624
PROTECT LANDSCAPING as per Dublin's Landscape Inspector at
(614) 410-4660.
STREET TREES REQUIRED CONTACT PAULA CHOPE, CITY FORESTER
Call 410-4701 PRIOR to ORDERING AND INSTALLING for tree
placement
A Minimum of THREE, 2-1/2 Inch Caliper DECIDUOUS TREES
are required in the front yard of this lot, No
Closer than SEVEN FEET to a Side Property Line. YARD
TREES are to be chosen from the species listed on the
City of Dublin approved Street Tree List.
Installation will occur during the landscape phase of this
house. Placement of the THREE TREES will be Field-Verified
by The City PRIOR to INSTALLATION. CORNER and THROUGH
LOTS Shall Meet This requirement on all street
frontages.
Air conditioning units are NOT PERMITTED within
REQUIRED Side or Rear yards.
Screen ALL Mechanical Units & Service Structures to top of
This permit is granted on the express condition that said work shall in all respects,
conform to the ordinances of the City of Dublin and all laws of the State of Ohio
regulating construction, installation, repair and alteration and may be revoked at
any time upon violation of any provisions of law.
CITY OF DUBLIN
Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016
Phone: (614) 410-4670 • Inspection Line: (614) 410-4680
Page 2
Application Number . . . . . 07-00200991 Date 9/12/07
Revision number . . . . . . . 1
Special Notes and Comments
unit including utility features and air conditioning units.
Contact PLANNING DIVISION 410-4600
DIMENSIONAL SHINGLES REQUIRED.
WINDOW TRIM REQUIRED TO BE WOOD PER BALLANTRAE TEXT.
DIMENSIONAL SHINGLES REQUIRED.
POST LIGHT at DRIVEWAY with PHOTO CELL REQUIRED.
Fee summary Charged Paid Credited Due
Permit Fee Total 240.00 .00 .00 240.00
Plan Check Total .00 .00 .00 .00
Grand Total 240.00 .00 .00 240.00
This permit is granted on the express condition that said work shall in all respects,
conform to the ordinances of the City of Dublin and all laws of the State of Ohio
regulating construction, installation, repair and alteration and may be revoked at
any time upon violation of any provisions of law.
CITY OF DUBLIN
Division of Building Standards • 5800 Shier - Rings Road • Dublin, Ohio 43016
Phone: (614) 410-4670 • Inspection Line: (614) 410-4680
Application Number: 7,7_001N
SURVEYOR
BUILDING LOCATION AND FIRST FLOOR ELEVATION
CERTIFICATION FORM
I, the undersigned, do hereby certify the following location of building and elevation of top of the
foundation wall at the referenced property. It is the builder's responsibility to insure that the
location and elevation of the top of the foundation wall plus the first floor system, as per the
approved prints, comply with the site plan approved by the City of Dublin (in reference to the
City of Dublin Codified Ordinance 1305.02(k)).
Property Owner: SHOWCASE HOMES
Subdivision: BALLANTRAE SEC. 7
Lot Number: 558
Address: 5937 VANDELEUR PLACE
Approved Foundation Elevation 942.8 Feet above mean sea level.
Actual Top of Foundation 942.88 Feet above mean sea level.
STEVEtI
Professional Seal:
7313
Signature of Surveyor:
8/2/2007
Date
This form is to be completed prior to the foundation inspection and must be made available on-site with
the approved prints.
7- S'- 07
INTERNATIONAL ENERGY CODE COMPLIANCE ADDENDUM
DATE: 1/3/2006
FROM: CORNERSTONE ENERGY
RE: DUCT INSULATION IN UNCONDITIONED AREAS
We have communicated with Dublin Building Department and the municipality has
explained to us they will be enforcing ductwork outside the conditioned en. elope to
be insulated at R-8 starting immediately. Please attach this page to your current
IECC's for code submittals.
Unconditioned Ducts:
- All ductwork located outside the conditioned building envelope will be insulated to R-8.
Co *10 one
Enerrlcce
Chris Patterson
Estimator
Energy Star Rater
Office: 614-351-1439 Ext. 228
Fax: 614-351-6650
N ex t el: 614-554-8644 136* 41 * 6831
Email: chris.patterson@nstalled.net
lFoundation's4lErnmy-
eeiwFae3 ~kea? *we areuNO us
ENERGY CODE INSPECTION CHECKLIST
Date: June 15, 2005 Rating No.:
Building Name: Laurel Rating Org.: Foundations 4 Energy
Owners Name: Laurel Homeowner Phone No.: 614-891.4900
Property Various Raters Name: Chris Patterson
Address: Various, OH Raters No.: 06-02
Builders Name: Showcase Homes
Weather Site: Delaware, OH Rating Type: Based On Plans
File Name: Laurel Sunroom.blg Rating Date:
Building Information:
Conditioned Area (sq ft): 7699
Conditioned Volume (cubic ft): 62400
Insulated Shell Area (sq ft): 13055
The items below will be inspected for energy code certification. Any deviation from these specifications should be
brought to the attention of Chris Patterson, as soon as possible to assure that the project will still comply
with energy code requirements.
Ceilings:
[ ] 1. Attic: R30 Attc (2x4 24oc) (3038 s.f.)
R-19.0 continuous insulation, R-11.0 cavity insulation.
Name: Main Installation Quality: P A G Face / Inset
Comments/Location
[ ] 2. Vaulted: R30 Vault (2x4 24oc) (607 s.f.)
R-19.0 continuous insulation, R-11.0 cavity insulation.
Name: Vaulted Installation Quality: P A G Face / Inset
Comments/Location
Above-Grade Walls: _
[ ] 1. Wall: R13 (2x416oc) (3021 s.f.), Between conditioned space and ambient
R-0.0 continuous insulation, R-13.0 cavity insulation.
Name: 1st/2nd Flr Installation Quality: P A G Face / Inset
Comments/Location
REM/Rate - Residential Energy Analysis and Rating Software 01.41
This information does not constitute any warranty of energy cost or savings.
01985-2004 Architectural Energy Corporation, Boulder, Colorado.
ENERGY CODE INSPECTION CHECKLIST
Laurel Page 2
2. Wall: R13 (2x416oc) (344 s.f.), Between conditioned space and garage
R-0.0 continuous insulation, R-13.0 cavity insulation.
Name: Buffered Installation Quality: P A G Face / Inset
Comments/Location
Windows and Skylights:
Window-to-Wall Area Ratio: 0.22
[ ] 1. Window: U-0.36 SHG-0.43 (201 s.f., West), U-Value: 0.360, SHGC: 0.430
For windows without labeled U-factors, describe features:
Name: Front Orientation: West
Comments/Location
[ ] 2. Window: U-0.36 SHG-0.43 (160 s.f., South), U-Value: 0.360, SHGC: 0.430
For windows without labeled U-factors, describe features:
Name: Right Orientation: South
Comments/Location
[ ] 3. Window: U-0.36 SHG-0.43 (228 s.f., East), U-Value: 0.360, SHGC: 0.430
For windows without labeled U-factors, describe features:
Name: Rear Orientation: East
Comments/Location
[ ] 4. Window: U-0.36 SHG-0.43 (145 s.f., North), U-Value: 0.360, SHGC: 0.430
For windows without labeled U -factors, describe features:
Name: Left Orientation: North
Comments/Location
[ ] 5. Window: U-0.50 SHG-0.50 (9 s.f., North), U-Value: 0.500, SHGC: 0.500
For windows without labeled U-factors, describe features:
Name: Bsmt Orientation: North
Comments/Location
[ ] 6. Window: U-0.50 SHG-0.50 (9 s.f., South), U-Value: 0.500, SHGC: 0.500
For windows without labeled U-factors, describe features:
REM/Rate - Residential Energy Analysis and Rating Software v11.41
This information does not constitute any warranty of energy cost or savings.
®1985-2004 Architectural Energy Corporation, Boulder, Colorado.
ENERGY CODE INSPECTION CHECKLIST
Laurel Page 3
Name: Bsmt Orientation: South
Commentsli-ocation
[ j 7. Skylight: U-0.36 SHG-0.43 (18 s.f.), U-Value: 0.360, SHGC: 0.430
For skylights without labeled U-factors, describe features:
Name: Skylight Orientation: North
Comments/Location
Doors..
[ ] 1. Door. Steel-urth w/brk (22 s.f.), R-Value 4.4
Comments/Location
[ ] 2. Door: Steel-urth w/brk (19 s.f.), R-Value 4.4
Comments/Location
Frame Floors:
[ ] 1. Floor: R19 (2x10 16oc) (279 s.f.), Between conditioned space and garage
R-0.0 continuous insulation, R-19.0 cavity insulation.
Name: Cant.#1 Installation Quality: P A G Face / Inset
Comments/Location
[ ] 2. Floor: R19 (2xl016oc) (90 s.f.), Between conditioned space and ambient conditions
R-0.0 continuous insulation, R-19.0 cavity insulation.
Name: Cant.#2 Rear Installation Quality: P A G Face / Inset
Comments/Location
Foundation Walls:
[ ] 1. Wall: R5 813 GrdeDown (1818 s.f.), Between conditioned space and ambient/ground
R-0.0 interior continuous insulation, R-0.0 interior cavity insulation, R-5.0 exterior insulation.
Name: Basement Installation Quality: P A G Face / Inset
Comments/Location
2. Wall: R5 813 GrdeDown (331 s.f.), Between conditioned space and garage/ground
R-0.0 interior continuous insulation, R-0.0 interior cavity insulation, R-5.0 exterior insulation.
REM/Rate - Residential Energy Analysis and Rating Software v11.41
This Information does not constitute any warranty of energy cost or savings.
®1985-2004 Architectural Energy Corporation, Boulder, Colorado.
ENERGY CODE INSPECTION CHECKLIST
Laurel Page 4
Name: Bsmt. Buffer Installation Quality: P A G Face ! Inset
Comments/Location
Slab Floors:
[ J 1. Slab: Uninsulated (3186 s.f.)
R-0.0 perimeter insulation, R-0.0 under slab insulation.
Name: Basement Installation Quality: P A G Face / Inset
Comments/Location
Rim and Band Joists:
[ ] 1. Joist: 1 st/2nd Fir (309 sJ.), Between conditioned space and ambient
R-0.0 continuous insulation, R-13.0 cavity insulation.
Name: 1 st/2nd Fir Installation Quality: P A G Face / Inset
Commentsti-ocation
[ 2. Joist: 1 st/2nd Buff (32 s.f.), Between conditioned space and garage
R-0.0 continuous insulation, R-13.0 cavity insulation.
Name: 1st/2nd Buff Installation Quality: P A G Face / Inset
Comments/Location
Mechanical Equipment:
f ] 1. Heating: Fuekfired air distribution, Natural gas, 94.1 AFUE.
Make and Model Number.
[ ] 2. Cooling: Air conditioner, Electric, 10.0 SEER.
Make and Model Number:
[ ] 3. Water Heating: Conventional, Natural gas, 0.63 EF.
Make and Model Number.
Mechanical Ventilation System:
[ ] Mechanical ventilation system rated for, and capable of, providing continuous ventilation.
System shall include automatic timing controls.
System type: Exhaust Only
REM/Rate - Residential Energy Analysis and Rating Software v11.41
This Information does not constitute any warranty of energy cost or savings.
®1885-21)04 Architectural Energy Corporation, Boulder, Colorado.
ENERGY CODE INSPECTION CHECKLIST
Laurel Page 5
System description(make):
Air Leakage Control:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be type IC rated and installed with no penetrations; or, installed inside an
appropriate air-tight assembly with a 0.5" clearance from combustible materials and 3" clearance from
insulation.
Vapor Retarder:
[ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors.
Materials Identification:
[ ] Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R -values and glazing U-factors must be clearly marked on the building plans or
specifications.
Duct Insulation:
[ ] Ducts in conditioned basement must be insulated to R-0.0.
[ ] Ducts in conditioned basement must be insulated to R-0.0.
[ ] Ducts installed in exterior wall assemblies shall have at least 2" of rigid foam insulation with foil
facing installed between sheathing and duds.
Duct Construction:
[ ] All ducts must be sealed with mastic and fibrous backing tape. Pressure-sensitive tape may be used
for fibrous ducts. Duct tape is not permitted.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
[ ] Programmable Thermostat
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 120 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
REM/Rate - Residential Energy Analysis and Rating Software v11.41
This Information does not constitute any warranty of energy cost or savings.
®1985-2004 Architectural Energy Corporation, Boulder, Colorado.
ENERGY CODE INSPECTION CHECKLIST
Laurel Page 6
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pine Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature (°l' Up to 1" Up to 1.25" 1.5" to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum lnsuladon Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range(°F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled water, Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES
REM/Rate - Residential Energy Analysis and Rating Software v11.41
This information does not constitute any warranty of energy cost or savings.
®1885-2004 Architectural Energy Corporation, Boulder, Colorado.
2004 IECC ANNUAL ENERGY COST COMPLIANCE
Date: June 15, 2005 Rating No.:
Building Name: Laurel Rating Org.: Foundations 4 Energy
Owner's Name: Laurel Homeowner Phone No.: 614891-4500
Property Various Rater's Name: Chris Patterson
Address: Various, OH Raters No.: 06-02
Builder's Name: Showcase Homes
Weather Site: Delaware, OH Rating Type: Based On Plans
File Name: Laurel Sunroom.blg Rating Date:
Annual Energy Cost
2004 IECC As Designed
Heating: 2101 1437
Cooling: 268 171
Water Heating: 296 252
Lights & Appliances: 400 421
Photovoltaics: 0 0
Service Charge: 102 102
Total: 3167 2383 "
This home MEETS the annual energy cost requirements in accordance with Section 404 of the 2004
International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses
the requirements by 28.196.
• Design energy cost is based on the following systems:
Heating: Fuel-fired air distribution. 50.0 kBtuh, 94.1 AFUE.
Cooling: Air conditioner, 36.0 kBtuh, 10.0 SEER.
Water Heating: Conventional, Gas, 0.63 EF.
Window-to-Wall Area Ratio: 0.22
Blower door test: Htg: 0.35 Clg: 0.18 ACHnat
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been
changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system
efficiencies are set to the "prevailing federal minimum standards" as of November, 2004. These standards are
subject to change, and software updates should be obtained periodically to ensure the compliance calculations
reflect current federal minimum standards.
REWRate - Residential Energy Analysis and Rating Software v11.41
This information does not constitute any warranty of energy cost or savings.
®1985-2004 Architectural Energy Corporation, Boulder, Colorado.
RESPONSE ELECTRIC 2999 SWITZER "E
PHONE/FAX 276-8228 COLUMBUS, OHIO 43219
PANEL SCHEDULE
BRKR POS DESCRIPTION DESCRIPTION POS BRKR
40-AMP 1 220V 220V 2 30-AMP
2-POLE 3 WALL OVEN DRYER 4 2-POLE
40-AMP 5 AIR 220V 6 30-AMP
2-POLE 7 CONDITIONER COOKTOP 8 2-POLE
9 SPARE SPARE 10
11 SPARE SPARE 12
20-AMP 13 DINING ROOM FAMILY ROOM 14 20-AMP
20-AMP 15 DINETTE WASHER 16 20-AMP
20-AMP 17 MICROWAVE REFRIGERATOR 18 20-AMP
20-AMP 19 KITCHEN GFI BATH GFI 20 20-AMP
20-AMP 21 KITCHEN GFI WHIRLPOOL 22 20-AMP
15-AMP 23 FURNACE DISPOSAL 24 15-AMP
15-AMP 25 SUMP PUMP DISHWASHER 26 15-AMP
15-AMP 27 GARAGE GFI GDO OUTLET 28 15-AMP
15-AMP 29 SECURITY OUTLET GDO OUTLET 30 15-AMP
15-AMP 31 LIGHTING LIGHTING 32 15-AMP
15-AMP 33 LIGHTING LIGHTING 34 15-AMP
15-AMP 35 LIGHTING LIGHTING 36 15-AMP
15-AMP 37 LIGHTING LIGHTING 38 15-AMP
15-AMP 39 LIGHTING/SMOKEDET LIGHTING 40 15-AMP
LOAD CALCULATION SHEET
3314 SQUARE FOOT @ 3 VA PER FOOT 9942
2 GARAGE DOOR OPENERS-1500VA 3000
4 SMALL APPLIANCE CIRCUITS -1500 VA 6000
2 LAUNDRY CIRCUITS-1500 VA 3000
SUMP PUMP 1500VA 1500
110V FURNACE -1500 VA 1500
REFRIGERATOR-1500 VA 1500
WHIRLPOOL-1500 VA 1500
DISPOSAL-1500 VA 1500
DISHWASHER -1500 VA 1500
GENERAL LIGHTING LOAD 30942
1ST 10 KVA @ 100 % OF LOAD VALUE 10000 VA
REMAINING LOAD @ 40% 20942 8376.8 VA
220V COOKTOP 8000 VA
220V WALL OVEN 8000 VA
HEAT PUMP/AIR CONDITIONING 8800 VA
TOTAL LOAD 43176.8 VA
43176.8 VA / 240 VOLTS 179.9033333 AMPS
200 AMP SERVICE
rnnaerson w. Kot t 1 b 1 g aJ4 1 ebJ p. J
p 7 -.20 a ?4?t
Anderson/Wikoff
360 W. Waterloo
Canal Winchester Ohio, Oh 43110
Phone 614-834-1099
S/N# QL-080896-15326
Proposal To: Showcase homes
Dublin, OH
ROOM SUMMARY
Winter Square Latent + Sens ble - Total
Space Name BTUH Feet BTUH - Cool
BTUH BTUH Tons C.F.M.
Family 44,926.23 441 1,215.11 14,715.68 15,930.79 1.33 528
Hearth 3,699.58 180 787.86 3,006.87 3,794.74 0.32 125
KITCHEN 1,023.58 180 752.36 3,116.85 3,869.21 0.32 127
dINING 1,399.74 182 352.95 1,656.64 2,009.59 0.17 66
fOYER 3,436.13 56 764.82 2,418.26 3,183.08 0.27 105
dEN 1,157.21 169 349.16 1,564.74 11913.91 0.16 63
hALL 115.71 63 318.33 707.69 1,026.02 0.09 34
mASTER bED 1,275.30 240 369.82 1,641,84 2,011.66 0.17 66
mASTER bATH 1,267.48 160 337.24 1,938.19 2,275.42 0.19 75
LAUNDRY & Cl 501.41 156 336.31 1,562.21 1,898.51 0.16 63
Bonus Room 2,663.48 504 717.30 3,455.15 4,172.44 0.35 137
Bedroom #2 1,200.79 192 344.68 1,540.31 11885.00 0.16 61
Bedroom #3 973.35 156 336.31 1,404.22 1,740.52 0.15 57
Bedroom #4 1,059.79 168 339.10 1,435.45 1,774.55 0.15 58
Loft 126.28 84 319.55 866.94 1,186.49 0.10 40
Hall Bath 170.74 60 163.96 670.00 833.97 0.07 27
Bedroom#413at 129.11 40 159.31 630.53 789.84 0.07 25
,rot is 65,125.91 3,031 7,964.17 42,331.57 50,295.75 4.19 1,655.4
Computed results should be treated as estimates only as the weather,
3uct & structure design may vary. Be sure and size systems based on there
I.bility to meet both the sensible and latent heat requirements, not just
:.he total btuh.
06/21/2007 08:57 614-241-2080 EDWARDS PAGE 02
park d BaAa&I Golf Comm=4
" cbitectuxal Review Committee
plan Approval Notification
Lot Number: 558 Section: 7 Dater 06/20/07
Address: $937 Yandeleur Place
Budder. Showcase Homes
plans for the above referenced Lot have been reviewed by the D Umtrae Architectural
Review Committw for compliance with:
¦ Architectural Diversity Standard.
¦ Exterior MILtedals Usage
¦ F=ont Yard Set Back Requirements
¦ Site Plan Requirements
plans are approved as submitted for the above referenced eICMente.
¦ No Further Approvals Required O Additional Approvals Required as Follows:
Approval CerdW by: n p
Charles P. Driscoll, Member
plans reviewed by Atchltectuxal Review Committee mesa
O P-awB&=* B&w& GOVC= , I.LC D JCe~ryJteeQ iLaadoq~ i ~jnats Sc dmbetger
¦ Cbados P. J aoa4 O"CoMMOMld ws LLC O 11fte~d Jioe, . d,FJ'o rk.4 Aas *
L7 Brian Jrecr joaesy Arc hfowt
CITY OF DUBLIN
Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016
Phone: (614) 410-4670 • Inspection Line: (614) 462-3865 (Franklin County)
Application No. Q T • ZC7~ q '1
Date V '.21 b~ J~
ew ? Remodel esidential ? Commercial
APPLICATION FOR PLUMBING PERMIT
The undersigned hereby applies for a permit to do plumbing and an inspection of same at the following location in accord with
Chapter 4101:2-51 of the Ohio Administrative Code, and all regulations of the Franklin County Board of Health.
Job Address 3 MvcW c. V o, Pte 'C Parcel No.
Subdivision/Project Name I~Pl,~A.-) AA A ~ Lot No. S S 8
Owner's Name ~Ow~o me Telephone TI g~ S &0 Z)
Contractor's Name A CC V 0-Art2 P (v rn Y"~ N C Telephone S.2 b -d IS
/
Contractor's Address 7 S 9 5- f S c. Dublin Registration Number o7 --1 7
Does the sewer discharge into an individual sewage disposal system or sanitary sewer? Sat\j 1- 7m ~4
How far distant from any dwelling, well or cistern is the sewage tank? 10,
p~
What is the size of the main drain? Of what materials do the vent pipes consist?
Of what material does the house drain consist? 4J
*INDICATE NAME OF CERTIFIED BACKFLOW TESTER
INSTRUCTIONS
This form must be properly filled out and returned to the office of the City of Dublin at least four days prior to the date of the FIRST INSPECTION,
accompanied by a fee calculated upon the following basis:
RESIDENTIAL COMMERCIAL
Application for permit & first fixture $50.00 Application for permit & first fixture $60.00
3 Number of remaining fixtures X $10.00 = ~c• Number of remaining fixtures X $12.00 = $
Total Inspection Fee $390 Total Inspection Fee
Re-inspection fee (based upon disapproved Inspection and collected by the Franklin County Board of Health ONLY) $45.00
Qt Qty- Qty.
Air Admittance Valve Garbage Disposal I Showers r
*Backfiow Preventers Hot Water Heater Sterilizers
Bath Tubs Interceptor Sump Pump
Bed Pan Washers Kitchen Sink Trap Primer
Bidet Laundry Trays Urinal
Chemical Sinks Lavatories Wash Fountain
Dental Cuspidors Mop Sinks Washing Machine
Dilution Sump Outside Faucets Water Closets
Dish Washers Roof Drains Water Lines f
Drinking Fountain Rough-in Openings for Future Water Storage Tank
Floor Drains Sewage Ejectors Other
Garage Catch Basin GRAND TOTAL 61
HOT WATER TANK RE LACE ENT FEE $35.00
Division of Building Standards c~.~
CITY OF DUBLIN
• Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016
Phone: (614) 410-4670 • Inspection Line: (614) 410-4680
Application Number . . . . . 07-0.0200991 Date 8/28/07
Revision number . . . . . 1
Property Address . . . . . . 5937 VANDELEUR PL
Parcel Number: 274-001170
Alternate Address: BALLANTRAE 7 #558
Tenant nbr, name . . . . . . SQ FT 5911
Application type description. RES SINGLE FAMILY DETACHED
Property owner . . . . . . . M/I Homes of Central Ohio,LLC
Contractor . _-_------_--M/I-HOMES OF CENTRAL OHIO, LLC
Permit . . . . . . PLUMBING PERMIT
Additional desc . .
Permit Fee . . . . 380.00 Plan Check Fee .00
Issue Date Valuation 0
Expiration Date . . 5/22/10
Qty Unit Charge Per Extension
BASE FEE 50.00
33.00 10.0000 EA RES PLUMBING >1 FIXTURE 330.00
Special Notes and Comments
NOTICE TO APPLICANT
SEPARATE OWNER/CIVIC ASSOCIATION REVIEW AND APPROVAL MAY BE
REQUIRED BY DEED. APPLICANT IS RESPONSIBLE FOR COMPLIANCE
WITH ALL APPLICABLE RESTRICTIVE COVENANTS AND DEED
RESTRICTIONS REQUIRED BY TITLE.
SIDEWALKS REQUIRED
Contact ENGINEERING to coordinate 614-410-4624
PROTECT LANDSCAPING as per Dublin's Landscape Inspector at
(614) 410-4660.
STREET TREES REQUIRED CONTACT PAULA CHOPE, CITY FORESTER
Call 410-4701 PRIOR to ORDERING AND INSTALLING for tree
placement
A Minimum of THREE, 2-1/2 Inch Caliper DECIDUOUS TREES
are required in the front yard of this lot, No
Closer than SEVEN FEET to a Side Property Line. YARD
TREES are to be chosen from the species listed on the
City of Dublin approved Street Tree List.
Installation will occur during the landscape phase of this
house. Placement of the THREE TREES will be Field-Verified
by The City PRIOR t'o INSTALLATION. CORNER and THROUGH
LOTS Shall Meet This requirement on all street
frontages.
Air conditioning units are NOT PERMITTED within
REQUIRED Side or Rear yards.
Screen ALL Mechanical Units & Service Structures to top of
This permit is granted on the express condition that said work shall in all respects,
conform to the ordinances of the City of Dublin and all laws of the State of Ohio
regulating construction, installation, repair and alteration and may be revoked at
any time upon violation of any provisions of law.
CITY OF DUBLIN
Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016
Phone: (614) 410-4670 - Inspection Line: (614) 410-4680
Page 2
Application Number . . . . . 07-00200991 Date 8/28/07
Revision number . . . . . . . 1
Special Notes and Comments
unit including utility features and air conditioning units.
Contact PLANNING DIVISION 410-4600
DIMENSIONAL SHINGLES REQUIRED.
WINDOW TRIM REQUIRED TO BE WOOD PER BALLANTRAE TEXT.
DIMENSIONAL SHINGLES REQUIRED.
POST LIGHT at DRIVEWAY with PHOTO CELL REQUIRED.
Fee summary Charged Paid Credited Due
Permit Fee Total 380.00 .00 .00 380.00
Plan Check Total .00 .00 .00 .00
Grand Total 380.00 .00 .00 380.00
This permit is granted on the express condition that said work shall in all respects,
conform to the ordinances of the City of Dublin and all laws of the State of Ohio
regulating construction, installation, repair and alteration and may be revoked at
any time upon violation of any provisions of law.
CITY OF DUBLIN
Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016
Phone: (614) 410-4670 • Inspection Line: (614) 410-4680
Application Number . . . . . 07-00200991 Date 7/23/07
Revision number . . . . . . . 1
Property Address . . . . . . 5937 VANDELEUR PL
Parcel Number: 274-001170
Alternate Address: BALLANTRAE 7 #558
Tenant nbr, name . . . . . . SQ FT 5911
Application type description RES SINGLE FAMILY DETACHED
Property owner . . . . . . . M/I Homes of Central Ohio,LLC
Contractor . . . . . . . . . M/I HOMES OF CENTRAL OHIO, LLC
Permit . . . . . . RESIDENTIAL BUILDING PERMIT
Additional desc . .
Permit Fee . . . . 540.00 Plan Check Fee .00
Issue Date . . . . '7.23-0-7 Valuation . . . . 0
Expiration Date . . 1/19/08
Qty Unit Charge Per Extension
BASE FEE 140.00
10.00 40.0000 RES BLDG PLAN REVIEW 400.00
Permit . . . . . . RES HEATING, VENTILATING, A.C.
Additional desc . .
Permit Fee . . . . 250.00 Plan Check Fee .00
Issue Date . . Valuation 0
Expiration Date 1/19/08
Qty Unit Charge Per Extension
BASE FEE 50.00
10.00 20.0000 RES HVAC 200.00
Permit . . . . . . LOW VOLTAGE ELECTRICAL PERMIT
Additional desc .
Permit Fee . . . . 140.00 Plan Check Fee .00
Issue Date . . Valuation . . . . 0
Expiration Date . . 1/19/08
Qty Unit Charge Per Extension
BASE FEE 40.00
10.00 10.0000 RES ELECTRICAL LOW VOLTAGE 100.00
Permit . . . . . . GAS LINE PERMIT
Additional desc .
Permit Fee . . . . 70.00 Plan Check Fee .00
Issue Date Valuation . . 0
Expiration Date . . 1/19/08
Qty Unit Charge Per Extension
This permit is granted on the express condition that said work shall in all respects,
conform to the ordinances of the City of Dublin and all laws of the State of Ohio
regulating construction, installation, repair and alteration and may be revoked at
any time upon violation of any provisions of law.
CITY OF DUBLIN
Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016
Phone: (614) 410-4670 - Inspection Line: (614) 410-4680
Page 2
Application Number . . . . . 07-00200991 Date 7/23/07
Revision number . . . . . . . 1
Qty Unit Charge Per Extension
BASE FEE 70.00
Permit . . . . . . WATER PERMIT
Additional desc . .
Permit Fee . . . . 1600.00 Plan Check Fee .00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 1/19/08
Qty Unit Charge Per Extension
1.00 1600.0000 EA WATER DUBLIN .75" WATER TAP 1600.00
Special Notes and Comments
NOTICE TO APPLICANT
SEPARATE OWNER/CIVIC ASSOCIATION REVIEW AND APPROVAL MAY BE
REQUIRED BY DEED. APPLICANT IS RESPONSIBLE FOR COMPLIANCE
WITH ALL APPLICABLE RESTRICTIVE COVENANTS AND DEED
RESTRICTIONS REQUIRED BY TITLE.
SIDEWALKS REQUIRED
Contact ENGINEERING to coordinate 614-410-4624
PROTECT LANDSCAPING as per Dublin's Landscape Inspector at
(614) 410-4660.
STREET TREES REQUIRED CONTACT PAULA CHOPE, CITY FORESTER
Call 410-4701 PRIOR to ORDERING AND INSTALLING for tree
placement
A Minimum of THREE, 2-1/2 Inch Caliper DECIDUOUS TREES
are required in the front yard of this lot, No
Closer than SEVEN FEET to a Side Property Line. YARD
TREES are to be chosen from the species listed on the
City of Dublin approved Street Tree List.
Installation will occur during the landscape phase of this
house. Placement of the THREE TREES will be Field-Verified
by The City PRIOR to INSTALLATION. CORNER and THROUGH
LOTS Shall Meet This requirement on all street
frontages.
Air conditioning units are NOT PERMITTED within
REQUIRED Side or Rear yards.
Screen ALL Mechanical Units & Service Structures to top of
unit including utility features and air conditioning units.
Contact PLANNING DIVISION 410-4600
DIMENSIONAL SHINGLES REQUIRED.
WINDOW TRIM REQUIRED TO BE WOOD PER BALLANTRAE TEXT.
This permit is granted on the express condition that said work shall in all respects,
conform to the ordinances of the City of Dublin and all laws of the State of Ohio
regulating construction, installation, repair and alteration and may be revoked at
any time upon violation of any provisions of law.
CITY OF DUBLIN
Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016
Phone: (614) 410-4670 - Inspection Line: (614) 410-4680
Page 3
Application Number . . . . . 07-00200991 Date 7/23/07
Revision number . . . . . . . 1
Special Notes and Comments
DIMENSIONAL SHINGLES REQUIRED.
POST LIGHT at DRIVEWAY with PHOTO CELL REQUIRED.
Other Fees . . . . . . . . . RES BLDG INSPECTION 550.00
RES CERTIFICATE OF OCC 30.00
SEWER DUBLIN 2000.00
SEWER COLUMBUS 3044.00
SEWER INSPECTION FEE 120.00
Fee summary Charged Paid Credited Due
Permit Fee Total 2600.00 .00 .00 2600.00
Plan Check Total .00 .00 .00 .00
Other Fee Total 5744.00 .00 .00 5744.00
Grand Total 8344.00 .00 .00 8344.00
This permit is granted on the express condition that said work shall in all respects,
conform to the ordinances of the City of Dublin and all laws of the State of Ohio
regulating construction, installation, repair and alteration and may be revoked at
any time upon violation of any provisions of law.
APPLICATION FOR BUILDING PERMIT
This form is provided by the Building Industry Association of Ohio as a public service.
THE Builders PERMIT NUMBER O • 20 p C} G}
Issued in Ohio Under Authority of PTUQ
c
~ Auditors Taxing District 274 Parcel Number 001170
t Address of Property 5937 VANDELEUR PLACE
JUL 02 2007
ow
0
Subdivision BALLANTRAE -7 Lot 558 arc 3~: t~i tee
U++t0 !Iv -_O2PQQAT1 Q
Applicants Name John Blazer Phone Number (614) 418-8831
Email Address jblazer@showcasehomes.com Fax Number (614) 418-8889
Owner's Name M/I Homes of Central Ohio, LLC Phone Number (614) 418-8831
DBA: Showcase Homes
Address 3 Easton Oval #240 Columbus, Ohio 43219
Designer's Name M/I Homes of Central Ohio, LLC Phone Number
a DBA: Showcase Homes (641) 418-8831
Q Address 3 Easton Oval #240 Columbus, Ohio 43219
Builder's Name M/I Homes of Central Ohio, LLC Phone Number (614) 418-8831
DBA: Showcase Homes
Address 3 Easton Oval #240 Columbus, Ohio 43219
Builder's ID 4533
Type of Improvement New One-Family Residential Improvement Cost $325,000.00
Number of Bedrooms 4 Heating Fuel Natural Gas Number of Gas Appliances 5
Per Unit
Number of Baths 3 full 1 half Sewage Disposal Public Garage Type Attached
Building Height 31 Water Supply Public Number Car Garage 3
o Building Zoning
Unfinished Basement 1935 IV/f> Lot Area 14,810
Finished Basement 0 Total % Occupied by Structure 19.22%
Lower Level 0 Front Setback 26.0'
1st Floor 2078 a~ Rear Setback 60.65'
2nd Floor
1236 ( 0;' 3/ Right Setback 15.5
a 3rd Floor 0 Left Setback
Other 18.57
0 Lot Width at Building Line 116.0'
Garage 662 (4 aZ
Deck/Screened In Porch 0 Zoning District PRD
Gross Square Feet 5911 Existing Use of Property VACANT LOT
Building Area at Ground Level 2847 7"0
Living Area 2958 Flood Plain ? YES ® NO
0
Z
Excavator License Number Fee Schedule
Plumbing License Number
Initial
Electric License Number Occupancy
HVAC License Number
Footage
Fireplace License Number Zoning
a
0
U
This section only to be filled out if required by Jurisdiction. Alt/Addtn.
The owner of this building and undersigned, do hereby covenant and agree to comply with all the laws of the Plan Exam
p, State of Ohio and the ordinances of this jurisdiction, pertaining to building and buildings, and to construct the
proposed building or structure or make the proposed change or alteration in accordance with the plans and Gas Piping
a. specifications submitted herewith, and certify that the information and statements given on this application,
9:6 9 drawings and specifications are to ththeir knowl true and correct. Other
Signature of Applican ~/21 /CE7
Total
Date Received D to Received Date Received
Date Approved Date Approved
7' S. o T Date Approved #7 23 -o
i I
CITY OF DUBLIN
Division of Building Standards -
nspectioniLlneR(614) 410-4680 Ohio 43016
Phone: (614)
These drawings have been reviewed for and shall comply with the 2004 Edition of the
Residential Code of Ohio.
PLAN REVIEW CHECKLIST
o "ago g 0 -0
Application No. °
C. a m
E
Date Reviewed a m 0 o
a c a Plan Reviewer's Comments & Notes
Reviewed By v z m ii a
u, is 'a o
Approved Disapproved o Z
c C
OBBC Model Energy Code MEC Check worksheet required
Manual J/Electdc Loads Houses over 3,000 Sq. Ft.
Ordinance Stair Risers & Treads 7 314" max. riser 10" min. treads and 6 8" headroom
R303.6 Stairway Illumination
R311 Handrails & Guards
R312
Schedules Required on Plans; houses, additions and
R303.1 Light & Ventilation Schedules sunrooms
Figure 307.2
rR3 06Sanitation -Fixture Clearance
07
R308 Required Safety Glazing
1318" s. c. or 20 min. door and 518" gyp. Bd. Type 'k' on
R309 Attached Garage Fire Separation all common walls per City Ordinance
5.7 sq. ft. (24' net hgt. 20" net width) max. window still
R310 Bedroom Emergency Egress hgt. Of44'a.f.f.
R311 Exits
R311.4.2.1 Interior Doors Bath 2'4""x 68", habitable space 216"x 6'8"(min)
R311.4.3 Landings Minimum X x 3'
R311.2.2 Understair Protection 112" gyp. Bd. Type '7C'
8smt.lhallway/bedrooms wired to prime electric/battery
R313 Smoke Detector Locations pack - uprnterconnected
Ordinance Carbon Monoxide Detector utside sleeping areas
R317 Foam plastic separation
R401.4.1 Soil bearing capacity Use 1,500 psf
R403 Footing/pier/pad size & location(s)
R403.1.6 Foundation anchorage 112" anchor bolt Q 6'0" oc, 7" into masonry & concrete
Stamped engineered foundation plan required for
R404 Foundation wall sizes & reinforcements V1 houses and additions
R405 Foundation drainage systems
R406 Damproofing or waterproofing
R502.3 Floor joist(s) allowable spans Lumber specifications required on drawings
R502.5 Allowable girder spans Per Tables R502.5(1) & R502.5(2)
R502.6 Bearing 112" for wood & steel/ 3" for masonry & concrete
R502.11.4 Floor Trusses Engineered design required at Frame Inspection
PLAN REVIEW CHECKLIST
"a
o d
a ~ 3 d
E JO-
OC v
°L c y a Plan Reviewer's Comments & Notes
E
o Z
m a a
0 M
7
0 Z
a >
~
R503 Floor sheathing
R(402.2) Concrete floors on ground
R 506
R602 Wood wall framing
R602.7 Headers Tables 502.5(1) & R502.5(2)
R602.10 Wall bracing
R603 Steel wall framing
R703.7 Masonry veneer Table 703.4
R802 Wood roof framing Show truss profiles on roof plan
R802.3 Framing details Rafter ties, joist not perpendicular to rafters
R802.4 Allowable ceiling joist spans
R802.5 Allowable rafter spans
R802.10 Roof trusses Stamped engineered roof trusses required at framing
inspection
R807.1 Attic access 2 "x 30"
R1001 Masonry chimneys Spark arrestor with rain cap per City Ordinance
R1002 Facto built chimneys Spark arrestor with rain ca
R1003 Masonry fireplaces Table 1003.1 & Figure 1003.1
R1004 Factory built fireplaces
R1005 Exterior air supply
M1701 Combustion air 50 cubic per 1,000 btu/h
R602.3.1 Stud size & spacing Table R602.3.1(2)
Front & Back Form
Revised 04/12/05
CITY. 01V DUBLIN
Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016
Phone: (6:14) 410-4670 • inspection Line: (614) 410-4680
Revision Application
RECEIVED J
Revision Fee $ JAN 01 2008
BUILDINOF DUBLtNN
Application Number Q-j_2 CITY
Address \JqNpELF,
Reason for Revision A22 Co - -Rq1T:? 63tk2~i)
r epc E AT C = PCNNF-,
"Note: All revisions must be clearly highlighted or clouded
on all the revised plans and plot plans."
Contact Name 13LAZ.-.P_
Contact Phone Number ( -~4 l=3
For office use only
Revision is to be reviewed by:
Building Division
Planning/Zoning Division
Engineering Division
Major Revision
Minor Revision
Supplemental Information
Updated 8-23--04