Loading...
07200810 Permit File CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 RESIDENTIAL OCCUPANCY PERMIT e This is to certify that I have inspected the residence ' described below and approved it for occupancy. 04 ADDRESS: PERMIT NO.: 7~2~l0 BY FINAL INSPECTION DATE: Building Permit No.: 01- 2,o NcJC) Project Address: Inspection Date AP DA Ins Comments Inspection Date AP DA Ins Comments Plumbing Insulation 2-7 o7 41~- Sdf SeG SUP Underground round Sewer Footing Final Electric Foundation 'f 2v 07 Final Steel Plumbing 3 Foundation 7 L~ ,9 W~- Final HVAC D$ to Sdf Radon e'7 Final Gas ad 1 2 i GT" ,l' - B-Ase " klF>1 Preslab Piping Rough Engineering Electric (CWA) Engineering 7~yg 44 Electric (Pre-Sod) Service Final Rough L i o,,(4 Engineering 41* JIC -#4,0 f '4t>*''Wo Plumbing Gas Piping -1y KcMe~le 5ac(o~tu-Mff lc~~ (Rough) °12517 /P Z0 D X Rough HVAC ip oq-p1 jr ~j Final Zoning X Fireplace tole 4 ;.k APP l Ram Zoning Rough/ .c,4 C-?.c" ~r`°[r~ /C,tx M"' Occupancy 101f . sfi 5~ suP x Framing ~D IL-07 101~ Sfj C-Sly ITY OF DUBLIN 5800 Shier Rings Road C Dublin, Ohio 43016 Division of Engineering Phone: V/TDD 614-410-4600 Inspection Line: 614-410-4680 t"',, Fax: 614/761-6506 DO NOT REMOVE THIS SHEET FROM SITE ENGINEERING FINAL INSPECTION PLEASE PRINT ALL INFORMATION Applicant: Company: Site: ~QQ(~Tr i-t'n' a e rI n (Provide Detail Plot Plano ot) y. Lot No: Sd-~{ Application No: 71- Zjnnflt~ Subdivision: BUR11 Ir4C, PLEASE D• NOT MARK BELOW THIS LINE ? NNo/o Violations/Inspection Approved ? Violations/Disapproved Gr'Approved For Conditional Occupancy 1. Clean Curb & Gutter OJ:~ 4f2-3/08 ?10. Adjust Manhole to grade (Sanitary/Storm) W-11, (Ord. 28-98, Sec. 97.38) ? 11. Rebuild Manhole Throat (Sanitary/Storm) ? 2. Improper Approach (Ord. 59-74, Sec. 51.04) (Ord. 12-89, Sec. 153.210(A)) ?12. Improper Grading ? 3. Adjust Water/Gas service box to grade (Ord. 7-75, Sec. 150.040) ? 4. AdjGst]nlet to grade ?13. Clean Street/Clean Sidewalk (Ord. 7-75, Sec. 150.039(J)) 5. Erosion Control/Sod or Seed bt; 4(L3~o8 (O.R.C. 723.011) (Ord. 40-98, Sec. 53.090 (G)) ? 6. Replace Damaged Asphalt ?14. Adjust Watch Valve to Grade (Ord. 35-74, Sec. 97.37 (A & B)) Z1 (Mainline/Fire Hydrant) ? 7. Handicap Ramp (Install/Replace) . Install Grade Stakes OK 4"/Q5 (ADA Specification) (Policy 98-027) (Sec. 152.70) X1/ 6., Submit "As Built" Plot Plan OIV. 442-x/08 ? 8. Replace Damaged Curb, 5 ft. Minimum Sections (Policy 98-027) (Ord. 7-75, Sec. 150.038(C)) ?17. Driveway Exceeds 8% Maximum Slope ? 9. Replace Damaged Sidewalk/Bikepath (Policy 98-019) (Ord. 35-74, Sec. 51.04) ?18. Remove Erosion Control Measures Comments: Contact Building Division at 410-4680 for re-inspection when work has been completed. The Engineering Final Inspection must be approved prior to requesting an Occupancy Inspection by the Building Division. Inspector: Date: Re-Inspection: Approved ? Disapproved Inspector: Date: !Qz3_P8 Engineering Final Inspection WHITE - Site YELLOW - File E 304 rev. 12104 PP t~ 35 r-- -----9--- / M AR rAM I? RO.~ER v y Pv' 2i2-=j 9 Jam, T.C.93 ..3 J _ 98.0 938.5 x ` ' - _ 547 ^ 938.0 938.0 549 -9j-- _ - _ 438.0 550 T.C.936. Si 1 v rn ; 942.6 942.6 942.3 94 1.3 ` 941. 41.3 940.2 T C. 4zi 1 ....................................................................94 ...........94 8.. 1. f0'S; T. C. A 940.06 + 19 ~ 18 17, 16 ~ 0 ~*•--40 m T.'C.93 .01 ;940.10 40.58 940 3,2 I6 40.9 rn- 939.6 ~ N N ~v 524 23 555 ~m o _ 9.0 940.4 941.6 941.1 1941.7 40.6 38.0 939.1 941.1 2 T. C. 941.4 B-B T • R W 525 522 556 0 TO LAND SOYFUNS ERA/CE Surveyors North Sanduskyttreet Phone: 740-369-7577 Karen S. Coffman, P.S. 7845 _ -aware, Ohio 43015 FAX: 740-362-7577 Istvan Gajary, P.S. 8183 Retired, Frank Cello, P.S. 6612 SITE PLAN FOR ROBERT B. & JENNIFER E. MILLER F.F.E.=944.8 PROPERTY LOCATED IN ALEXANDRA BUILDING CO. & GARAGE=942.8 FLOOD ZONE "X" PER LOT 549, BALLANTRAE SECTION 7, FOOTER=934.8 FEMA NO. 39049C 0108 G PLAT BOOK 106, PAGES 16-18 HEIGHT OF WALL=9.0 AUGUST 2, 1995 BASEMENT FLOOR=935.1 CITY OF DUBLIN, FRANKLIN COUNTY, OHIO DRIVE SLOPE=4s3R 6000 TRAFALGAR LANE Na/o E, G. = P.G= 937.1 p.G= 937.2 S 84' 45' 03" W 100.00' A rn I I m m p C -V TC.=9j7,3 I ?S' NO BUILD ZONE v 111 25 x n R I 30' LANDSCAPE BUFFER r" M t~ Z P.G.= 9J8.0 n ~ ~ T fAS MENT P.C.= vy S Z - ti T 90 - M --4 to z~ I ~o I ;k v, C v~ I 3 u2 11 a I LOT 549 pG= 940.6 i 942.3 9423 p,G= 939.4 mr- 42.6 CZ 7' 0° T 548 13 I I W LOT 550 n 10 I I 942.3 to y * I - " r- 17.83 w •o- o r'+ A I r 22.5 u L0 10 Ln z 132. ' N PiOP. 9RES. N o M y 420 10.83 Fi E,G = X 9426 N vi 942.J p, G.940.2 WW ~ 2 0 1033 O >t J5' BUILDING _9423 942.3 - a qq0 ~n Eo.s=s3o.1 jLq -DURING CCNSTRUCT/QN, - - - _ _ - I-E.NO PARKING WLL BE ALLOWD ON THIS 940. E.G.= SAN/TARP GSIDE OF THE STREET P,G.= 7 2 EASEMENT LiNE G.= _ __EK6 Po osed ' PUC CCESS EAS_EMENT _ - - = _ B/KE'~ P.. A7H P 1y t 314 W00 R A BACK B -WA LINE 4' CURB 94 40. 93 .9 AF LGAR LANE ~ - W s LEGEND 0 z is xxx.xX = PROPOSED ELEVATIONS lCL GCOMPUANCE WATER VALVE City of Dublin FIRE HYDRANT APPROVED AS NOTED i CPP 06.28 • Off- ~ SANITARY MANHOLE EG= EXISTING AND This site plan is based on approved pG=XXx.X engineering PROPOSED ELEVATIo~ •w„ s for Ballontrae Subdivision, and represents (E OA/, builder's and homeowner's desired grading 0 t~ -i and was not designed by Scioto Land Surveying Service, Inc. KAREN d S. S - a i CO 045AN Q REVISED: JUNE 8, 2007 KAREN S. COFFM VEYOR 6 ZZ o7 DATE MAY 18, 2007 0~~ 9F~ISTq~~~'a~ Registration No. SS1OA 1.. t Sill rO AND s,,Yfy/#e SF,?Y/Cfl INC. Surywm 173 North Sandusky Sked 3857 Nash High Strad Karwt S. Cognmm% P.S. 780 Delaware. Ohio 43015 Cakadrus, Ohio 43214 Istm Galery, P.S. 8183 081w: 740 Fox 740.382.7577 OMo& 614283.7577 Fax 61"W.75" Retired, Frank CeW P.S. 6612 AS-BUILT SURVEY FOR ROBERT B. & JENNIFER E. MILLER ALEXANDRA BUILDING CO. & LOT 549, BALLANTRAE SECTION 7, PLAT BOOK 106, PAGES 16-18 CITY OF DUBLIN, FRANKLIN COUNTY, OHIO 6000 TRAFALGAR LANE 937.2 S 84 45' 03" W 100.00 I 25' NO zavE I 30' L4W rlI ffRW _lD _J L2 L---- rEAS OVT - - - - X °o I ® M4 i ° W I ° 1 o ( ® 9W.4 _ a ma Dla~ I Dotr Dtr.4 • oftl 43.0 LOT 548 I ~ D ®Di~' W LOT 550 6' 1- 0 I ~ o W Z w RESIDENCE o o U ea ! 32• I o ,a W e4r 3 ! r 35' maw "Zee I I U Q 44t3 avz 26.2 ! _ ~ are 20' EASEUNT I --5' A EASEBUdOWt----------------- _ 100.00_____----__ +o TREE FA LANE t W~ erg IO' 0= GROUND SHOTS '°°`o= DRIVE SHOTS X= GRADE STAKE y~P~E OF Oy~O SPOT ELEVATIONS BASED ON ACTUAL FIELD SURVEY KAREHI PERFORMED ON APRIL 21, 2008. S. 9 7846 O S 2.L O~ APRIL 21, 2008 O'~ 9tcQlST?~ SJ~ IRAREN Reg"~etrot. COFFMAN OR Date of Survey 8S+/ONAL CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 SUBCONTRACTOR DISCLOSURE General Contractor: H''1 e)~ax%,d-ra- Application No.: rj'" (Qrv.-N 2 Job Address: to poo alai Lo- n e.. The General Contractor is required to furnish the .following. information regarding any contractor working at the above address prior to .issuance of a Certificate of Occupancy. All subcontractor registrations musttbe. current through the issuance of a Certificate of Occupancy, including insurant d afl: applicable State Cert~fc,itians. TYPE A OF 00 --ACTOR DUBLIN REGISTRATION NO. EXCAVATION* CONCRETE* U.1 MASONRY n~? b,r, ` a: STRUCTURAL* L, Co. -4 _ E St -5 3 ELECTRICAL* f33 c S I PLUMBING*~ r,a•b: n HVAC -C:q 83 INSULATION c~ M 004' ; ROOFING* le, u~ I Co l - -S,?S DRYWALL 46- CZA I CJ. Co CEO b - s 5-3 SIDING k ? 53 SANITARY SEWER*. :S L o 1 ~ 0-4--71 ' LANDSCAPING -5 163 FIRE PROTECTION UNDERGROUND N r FIRE ALARM N FIRE SUPPRESSION 11C PAINTING ! 1 G~ ~I 593 OTHER *MUST BE COMPLETED AND AVAILABLE AT TIME OF FRAMING INSPECTION AND A COPY AVAILABLE FOR THE INSPECTOR TO TAKE TO OFFICE. Excel/Subcontractor Disclosure Update 2003 CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016... Phone: (614) 410-4670 Inspection Line: (614) 410-4680 SUBCONTRACTOR ft DISCLOSURE ~f ~7 -Sr53 General Contractor: JLJ 1 Q r~ Application No.: / aC02 Pte,,,, Job Address: j ^ ox L -0 L The General Contractor is required to furnish the following. information regarding any contractor working at the above address prior to issuance of a Certificate of Occupancy. All subcontractor registrations must be current through the issuance of a Certificate of Occupancy, including insurance,and aN.appl cable State Certiftcat ons. TYPE NAME OF CONTRACTOR DUBLIN REGISTRATION NO EXCAVATION* Po fr,1 CONCRETE* to MASONRY STRUCTURAL* in Co. 441. -4 _ ELECTRICAL* V t3a C 0773- - S 'q PLUMBING* f ~,~cszSZ 0.11,,, IrL b HVAC* S ng,4 f7 - S INSULATION ROOFING* ?~rte,2: Co t (9 2? S DRYWALL SIDING SANITARY SEWER*,/ 0-4-1 LANDSCAPING FIRE PROTECTION UNDERGROUND FIRE ALARM FIRE SUPPRESSION PAINTING OTHER *MUST BE COMPLETED AND AVAILABLE AT TIME OF FRAMING INSPECTION AND A COPY AVAILABLE FOR THE INSPECTOR TO TAKE TO OFFICE. ExceVSubcontractor Disclosure Update 2003 F*T17 200 Schofield Drive Whitehall, OH 43213 Engineered Lumber Phone: (614) 367-2273 Fax: (614) 367-9609 October 24, 2007 Job Name: Alexandra Building Co. - Lot 549 Ballantrae Issues: 1. First Floor 1 3/4" x 11 7/8" LVL (TS5) beam at stair opening was cut to 7" deep (for headroom clearance) across 4' width of stair. Solution or Proof: 1. This beam retains sufficient capacity to support the applied loads. No repair is required. Additional Comments: If you have any concerns or questions about the preceding information and included data please feel free to call me at our office at 614-367-2273 Thank you, ~~P .E:•0 F 0 JOHN John Schueler MICHAEL 614-332-1509 : SCHUELER 136*101*12981 ~O*0 5 1 • /STEa~bee p~`~s®ON~L Jobsite Letter for Alexandra Lot 549 BaUmt-doc Jul.26. 2007 8:38AM SCIOTO LAND SURVEYING No,1300 P. 2 CITY OF DUBLIN Division of Building Standards 0 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number: -7- 2000 ja SURVEYOR BUILDING LOCATION AND FIRST FLOOR ELEVATION CERTIFICATION FORM n ~f I, the 8 ~1gned,-do herebV certify the following location of)bdiklin# 1 nation of top of the foundatto i wail at the referenced property.. It le they bi tidet il6sponsibility to insure that the location and elevation ©f the. top Of.the foundation wall plus the first floor system, as per the approved prints, coirrlplywith: 6..s16; AM. approved by the City of Dublin (in reference to the City.of dubliri.Codified* 6Winait6e".1S6b. 0 (k)). Prope Owner: a; ;~xiilcl~hc Gc3 Subdivision: Lot Number: 4 Address "f t 1 al ar Approved Foundation Elevation qA& _Feat -aboVo mean sea level. Actual Top of Foundation W- S Feet above mean sea level. tl4''.,, _•'•~P .f ' 06 ..u..........., Professional Seal. _ GA,lARY ISNAN Si ature of rJUL or €O -c M3 ~ ~o9F ~L4. 2 6 2007 S G!5TE ~JP Date /0 NAL r This form is to be completed prior to the foundation inspection and must be made available on-ske with the approved prints. ExceUSurvey 02.N14 RECEIVED - APFLIGAmN FoR BUILDING ERMIT•, I( Lj This form is provided by the Building Industry Association of Ohi as a public l~rtfiV 0 5 2007 THE Builders PERMrr NUMBER O-4 2cKD0 t o a rC n I tee t o re r OHIO INt CP ?ATEJ Issued in Ohio Under Authority of C O ' Auditors Taxing District Parcel Number ~ ~n~ t n -I~ hll~ ~ ScY~~ S L Address of Property U ono -r~~~~,1 gam Ln. DUb1,; n L(3 o/ ~ a' Subdivision C>`\~ C&Y\}r RC -7 Lot S Y Y M., p Applicant's Name: -r r n - r^ 1 Phone Number: (ol (4 - S 9S =77 g Email Address:11,o M1),r 0t~P~Gf'tVtJhnK•Y, t Owner's Name y Fax Number: -740 - 9(-.5- 1-05 q S' ~o~OQti~ _ ~2 Kh7,~e? (e,`(~ Phone Number. {a/i( ~(o-(a s3Q V Address: L// Y7 IJIlnw yak . 11,\ 144,OW Designer's Name: ~a O25~C4NGro~~ y30a~ Phone Number. 61~ ~~s5 •c Q Address: f r y~ f X30 , wOAV, VLy4vy, to 4 Y30 d Builder's Name: AjQ_,.- .v, ka GC,4~t JCJ t to~ Co. ~ O. Phone Number. (f 1 \4 - S g 5-7 Address: 5 10 ke-VYN 2c~. t C,.,-cdejn cj Ott- 43 0 ;k- Builder's ID: Type of Improvement: 1V e o C;xm S 0 DOS ratC.t-a f~'~) Improvement Cost L1 Number of Bedrooms: q Heating Fuel: ~)aAWn 6b Number of Gas Appliances per Unit: y Number of Baths: 3 , S Sewage Disposal: Se;wP-A - O 411( + Garage I Building Height: Water Supply: L\1110 ~ btAblI~j Number Car Garage: 3 c Building C Zoning Ti Unfinished Basement 13L 5 t l 65 Lot Area :.-33 y Ac,, w 1,1S 14 ~q E Finished Basement Total % Occupied by Structure { S lip ~ Lower Level - 1st Floor 1`J-74 Front Setback 3 5 , S a 2nd Floor i 1 pg t- 01 Rear Setback tj V, rj 16. 3rd Floor N lot Right Setback 1 I. 5 Other Left Setback - b ,D Garage -1 I l T Lot Width at Building Line 10 0 r Deck/Screened In Porch N14 Gross Square Feet 3 J O~ 5 Zoning District Building Area at Ground Level ; -;La ha l 8 5 Existing Use of Property V ham,, . _ 5;,,) ~t Ct tun h I Y S . Living Area 3 Flood Plain Yes No The owner of this building and midaxigoed, do hereby coveaent and agree to comply with all the laws of the State of C Ohio and the ordinances of this jurisdiction, pate iroog to building and buildings, and to construct the proposed building o or structure or make the proposed change or alteration in accordance with the plans and specifications submitted a herewith, and certify that the infomhation and statements given on this application, drawings and specifications are to the best of their knowledge, true and caret. Q Ma Signature of Applicant fit Date Received Date Received Date Received v Date A roved 7-13 -Q' Date Approved Date Approved -1 g 0 Zoning Official T Plans Examiner suing Autho ty CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00200810 Date 7/16/07 Revision number . . . . . . . 1 Property Address . . . . . . 6000 TRAFALGAR LN Parcel Number: 274-001161 Alternate Address: BALLANTRAE 7 #549 Tenant nbr, name . . . . . . SQ FT Application type description RES SINGLE FAMILY DETACHED Property owner . . . . . . . Alexandra Building Co. Contractor . . . . . . . . . ALEXANDRA BUILDING CO LLC Permit . . . . . . RESIDENTIAL BUILDING PERMIT Additional desc . . Permit Fee . . . . 500.00 Plan Check Fee .00 Issue Date . . . . 7_/$,p q Valuation . . . . 0 Expiration Date . . 1/12/08 Qty Unit Charge Per Extension BASE FEE 140.00 9.00 40.0000 RES BLDG PLAN REVIEW 360.00 Permit RES HEATING, VENTILATING, A.C. Additional desc . . Permit Fee . . . . 230.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/12/08 Qty Unit Charge Per Extension BASE FEE 50.00 9.00 20.0000 RES HVAC 180.00 Permit. . . . LOW VOLTAGE ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 130.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date . . 1/12/08 Qty Unit Charge Per Extension BASE FEE 40.00 9.00 10.0000 RES ELECTRICAL LOW VOLTAGE 90.00 Permit . . . . . . GAS LINE PERMIT Additional desc . . Permit Fee . . 70.00 Plan Check Fee .00 Issue Date . . Valuation . . 0 Expiration Date . . 1/12/08 Qty Unit Charge Per Extension This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 07-00200810 Date 7/16/07 Revision number . . . . . 1 Qty Unit Charge Per Extension BASE FEE 70.00 Permit . . . . . . WATER PERMIT Additional desc . . Permit Fee . . . . 1600.00 Plan Check Fee .00 Issue Date Valuation . . 0 Expiration Date 1/12/08 Qty Unit Charge Per Extension 1.00 1600.0000 EA WATER DUBLIN .75" WATER TAP 1600.00 Special Notes and Comments Missing grade elevations,sanitary service(end of service elevation),water tap, sanitary lines and manholes, bikepath and 71treelwan. Missing first floor, top of block, and basement elevations. Driveway CANNOT encroach 10' easement where sanitary line and manholes should be. What is driveway slope? Incorrect flood plain data shown. Site plan must be stamped by registered surveyor or engineer. NOTICE TO APPLICANT SEPARATE OWNER/CIVIC ASSOCIATION REVIEW AND APPROVAL MAY BE REQUIRED BY DEED. APPLICANT IS RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE RESTRICTIVE COVENANTS AND DEED RESTRICTIONS REQUIRED BY TITLE. SAWCUT SIDEWALKS REQUIRED Contact ENGINEERING to coordinate 614-410-4624 PROTECT LANDSCAPING as per Dublin's Landscape Inspector at (614) 410-4660. STREET TREES REQUIRED CONTACT PAULA CHOPE, CITY FORESTER Call 410-4701 PRIOR to ORDERING AND INSTALLING for tree placement A Minimum of THREE, 2-1/2 Inch Caliper DECIDUOUS TREES are required in the front yard of this lot, No Closer than SEVEN FEET to a Side Property Line. YARD TREES are to be chosen from the species listed on the City of Dublin approved Street Tree List. Installation will occur during the landscape phase of this house. Placement of the THREE TREES will be Field-Verified by The City PRIOR to INSTALLATION. CORNER and THROUGH This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 3 Application Number . . . . . 07-00200810 Date 7/16/07 Revision number . . . . . . . 1 Special Notes and Comments LOTS Shall Meet This requirement on all street frontages. Air conditioning units are NOT PERMITTED within REQUIRED Side or Rear yards. Screen ALL Mechanical Units & Service Structures to top of unit including utility features and air conditioning units. Contact PLANNING DIVISION 410-4600 ENCOURAGE DRIVEWAY TO SIDELOAD GARAGE BE AT LEAST 25 FEET FROM GARAGE DOOR OPENING FOR EASE OF MANEUVERING. Other Fees . . . . . . . . . RES BLDG INSPECTION 510.00 RES CERTIFICATE OF OCC 30.00 SEWER DUBLIN 2000.00 SEWER COLUMBUS 3044.00 SEWER INSPECTION FEE 120.00 Fee summary Charged Paid Credited Due Permit Fee Total 2530.00 .00 .00 2530.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 5704.00 .00 .00 5704.00 Grand Total 8234.00 .00 .00 8234.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN 5800 Shier Rings Road Dublin, Ohio 43016 Phone: V/TDD 614-410-4600 Division of Engineering Inspection Line: 614-410-4680 Fax: 614/761-6506 DO NOT REMOVE THIS SHEET FROM SITE ENGINEERING FINAL INSPECTION r PLEASE PRINT ALL INFORMATION Applicant: ~e~- -1^OrLL ~1144 n5R' Company: Site: l0~ I CL-k- l~O-L LAYS.. (Provide Detail Plot Plan of Lot) Lot No: 154q Application No: U z(ao30 Subdivision: ) ~~n e- PLEASE D• NOT MARK BELOW THIS LINE ? No Violations/Inspection Approved ? Violations/Disapproved ? Approved For Conditional Occupancy ? 1. Clean Curb & Gutter ?10. Adjust Manhole to grade (Sanitary/Storm) (Ord. 28-98, Sec. 97.38) ? 11. Rebuild Manhole Throat (Sanitary/Storm) ? 2. Improper Approach (Ord. 59-74, Sec. 51.04) (Ord. 12-89, Sec. 153.210(A)) ?12. Improper Grading ? 3. Adjust Water/Gas service box to grade (Ord. 7-75, Sec. 150.040) ? 4. Adjust Inlet to grade ?13. Clean Street/Clean Sidewalk ? 5. Erosion Control/Sod or Seed (Ord. 7-75, Sec. 150.039(J)) (Ord. 40-98, Sec. 53.090 (G)) (O.R.C. 723.011) ? 6. Replace Damaged Asphalt ?14. Adjust Watch Valve to Grade (Ord. 35-74, Sec. 97.37 (A & B)) (Mainline/Fire Hydrant) ? 7. Handicap Ramp (Install/Replace)' ?15. Install Grade Stakes (ADA Specification) (Policy 98-027) (Sec. 152.70) ?16. Submit "As Built" Plot Plan ? 8. Replace Damaged Curb, 5 ft. Minimum Sections (Policy 98-027) (Ord. 7-75, Sec. 150.038(C)) ?17. Driveway Exceeds 8% Maximum Slope ? 9. Replace Damaged Sidewalk/Bikepath (Policy 98-019) (Ord. 35-74, Sec. 51.04) ?18. Remove Erosion Control Measures Comments: Contact Building Division at 410-4680 for re-inspection when work has been completed. The Engineering Final Inspection must be approved prior to requesting an Occupancy Inspection by the Building Division. Inspector: Date: Re-Inspection: ? Approved ? Disapproved ? Conditional Inspector: Date: Engineering Final Inspection WHITE - Site YELLOW - File E 304 rev. 12/04 PP CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Date 9 O~WI'A!7 Application No. 0 .2-00110 APPLICATION FOR ELECTRICAL PERMIT Job Address a u n! Parcel No Subdivision ~~l/mow L Lot No. Owner Nam C QAa'1 ! 6. Telephone Contractor Name Telephone Contractor Address N w~ Dublin Registration No. d' Residential: a New Sq. Ft.~ Alteration/Addition Sy. Ft. Temporary Service $40.00.. $40.00 Minimum plus $20.00 for each additiona1500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Low Voltage Systems: Square Feet $40.00 Minimum plus $10.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Commercial: New Sq. Ft. Alteration/Addition Sq. Ft. Temporary Service $60.00 $60.00 Minimum plus $60.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. and up to 50,999 Sq. Ft. (sizes above, See Fee Schedule) Low Voltage Systems: Square Feet $30.00 Minimum (plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.) 3% State of Ohio Surcharge (commercial only) Total $ JOB DESCRIPTION This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of Dublin, all the laws of the State and the National Electric Code regulating construction install ion, repair and alteration, and maybe revoked at anytime upon violation of any r isi of said laws. Z d. q~is/o r Signature of licensed contractor or homeowner Division of Building Standards Date: 1/1/2001 CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00200810 Date 9/26/07 Revision number . . . . . . . 1 Property Address . . . . . . 6000 TRAFALGAR LN Parcel Number: 274-001161 Alternate Address: BALLANTRAE 7 #549 Tenant nbr, name . . . . . . SQ FT Application type description RES SINGLE FAMILY DETACHED Property owner . . . . . . . Alexandra Building Co. Contractor . . . . . . . . . ALEXANDRA BUILDING CO LLC Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 220.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/24/08 Qty Unit Charge Per Extension BASE FEE 40.00 9.00 20.0000 RES ELECTRICAL SERVICE 180.00 Special Notes and Comments Missing grade elevations,sanitary service(end of service elevation),water tap, sanitary lines and manholes, bikepath and 71treelwan. Missing first floor, top of block, and basement elevations. Driveway CANNOT encroach 10' easement where sanitary line and manholes should be. What is driveway slope? Incorrect flood plain data shown. Site plan must be stamped by registered surveyor or engineer. NOTICE TO APPLICANT SEPARATE OWNER/CIVIC ASSOCIATION REVIEW AND APPROVAL MAY BE REQUIRED BY DEED. APPLICANT IS RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE RESTRICTIVE COVENANTS AND DEED RESTRICTIONS REQUIRED BY TITLE. SAWCUT SIDEWALKS REQUIRED Contact ENGINEERING to coordinate 614-410-4624 PROTECT LANDSCAPING as per Dublin's Landscape Inspector at (614) 410-4660. STREET TREES REQUIRED CONTACT PAULA CHOPE, CITY FORESTER Call 410-4701 PRIOR to ORDERING AND INSTALLING for tree placement A Minimum of THREE, 2-1/2 Inch Caliper DECIDUOUS TREES are required in the front yard of this lot, No Closer than SEVEN FEET to a Side Property Line. YARD TREES are to be chosen from the species listed on the This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 07-00200810 Date 9/26/07 Revision number . . . . . . . 1 Special Notes and Comments City of Dublin approved Street Tree List. Installation will occur during the landscape phase of this house. Placement of the THREE TREES will be Field-Verified by The City PRIOR to INSTALLATION. CORNER and THROUGH LOTS Shall Meet This requirement on all street frontages. Air conditioning units are NOT PERMITTED within REQUIRED Side or Rear yards. Screen ALL Mechanical Units & Service Structures to top of unit including utility features and air conditioning units. Contact PLANNING DIVISION 410-4600 ENCOURAGE DRIVEWAY TO SIDELOAD GARAGE BE AT LEAST 25 FEET FROM GARAGE DOOR OPENING FOR EASE OF MANEUVERING. Fee summary Charged Paid Credited Due Permit Fee Total 220.00 .00 .00 220.00 Plan Check Total .00 .00 .00 .00 Grand Total 220.00 .00 .00 220.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 462-3865 (Franklin County) Application No. Q4 • ZM6 1 0 Date ~~Z 3 7 ? New ? Remodel ? Residential ? Commercial APPLICATION FOR PLUMBING PERMIT The undersigned hereby applies for a permit to do plumbing and an inspection of same at the following location in accord with Chapter 4101:2-51 of the Ohio Administrative Co and all regulations of the Franklin County Board of Health. Job Address 1"v / R &AR Parcel No. t Subdivision/Project Name GAA APJAILA ~ Lot No Owner's Name Ate"Atk&A CX_ S Telephone r I ~`1DQ. y-~119~ y/7 Contractor's Name _~4,C n -Telephone Contractor's Address Dublin Registration Number Does the sewer discharge into an individual sewage disposal system or anitary sew How far distant from any dwelling, well or cistern is the sewage tank? - It What is the size of the main drain? Ll Of what materials do the vent pipes consist? Of what material does the house drain consist? P *INDICATE NAME OF CERTIFIED BACKFLOW TESTER INSTRUCTIONS This form must be properly filled out and returned to the office of the City of Dublin at least four days prior to the date of the FIRST INSPECTION, accompanied by a fee calculated upon the following basis: RESIDENTIAL COMMERCIAL Application for permit & first fixture.............. $50.00 Application for permit & first fixture $60.00 Number of remaining fixtures X $10.00 = $4~ Number of remaining fixtures X $12.00 = $ Total Inspection Fee $ Total Inspection Fee Re-inspection fee (based upon disapproved Inspection and collected by the Franklin County Board of Health ONLY) $45.00 Qty. Qty. Qty. Air Admittance Valve Garbage Disposal Showers / *Backflow Preventers Hot Water Heater / Sterilizers Bath Tubs -1j Interceptor Sump Pump Bed Pan Washers Kitchen Sink Trap Primer Bidet Laundry Trays Urinal Chemical Sinks Lavatories Wash Fountain Dental Cuspidors Mop Sinks Washing Machine Dilution Sump Outside Faucets Water Closets Dish Washers / Roof Drains Water Lines Drinking Fountain Rough-in Openings for Future Water Storage Tank Floor Drains Sewage Ejectors Other Garage Catch Basin GRAND TOTAL H WATER TAN RELPLACEM NT FEE 35.00 Division of Building Standards I Z %A 101:4 CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00200810 Date 8/24/07 Revision number . . . . . . . 1 Property Address . . . . . . 6000 TRAFALGAR LN Parcel Number: 274-001161 Alternate Address: BALLANTRAE 7 #549 Tenant nbr, name . . . . . . SQ FT Application type description RES SINGLE FAMILY DETACHED Property owner . . . . . . . Alexandra Building Co. Contractor . . . . . . . . . ALEXANDRA BUILDING CO LLC Permit . . . . PLUMBING PERMIT Additional desc . . Permit Fee . . . . 290.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/18/10 Qty Unit Charge Per Extension BASE FEE 50.00 24.00 10.0000 EA RES PLUMBING >1 FIXTURE 240.00 Special Notes and Comments Missing grade elevations,sanitary service(end of service elevation),water tap, sanitary lines and manholes, bikepath and 71treelwan. Missing first floor, top of block, and basement elevations. Driveway CANNOT encroach 10' easement where sanitary line and manholes should be. What is driveway slope? Incorrect flood plain data shown. Site plan must be stamped by registered surveyor or engineer. NOTICE TO APPLICANT SEPARATE OWNER/CIVIC ASSOCIATION REVIEW AND APPROVAL MAY BE REQUIRED BY DEED. APPLICANT IS RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE RESTRICTIVE COVENANTS AND DEED RESTRICTIONS REQUIRED BY TITLE. SAWCUT SIDEWALKS REQUIRED Contact ENGINEERING to coordinate 614-410-4624 PROTECT LANDSCAPING as per Dublin's Landscape Inspector at (614) 410-4660. STREET TREES REQUIRED CONTACT PAULA CHOPE, CITY FORESTER Call 410-4701 PRIOR to ORDERING AND INSTALLING for tree placement A Minimum of THREE, 2-1/2 Inch Caliper DECIDUOUS TREES are required in the front yard of this lot, No Closer than SEVEN FEET to a Side Property Line. YARD TREES are to be chosen from the species listed on the This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 07-00200810 Date 8/24/07 Revision number . . . . . . . 1 Special Notes and Comments City of Dublin approved Street Tree List. Installation will occur during the landscape phase of this house. Placement of the THREE TREES will be Field-Verified by The City PRIOR to INSTALLATION. CORNER and THROUGH LOTS Shall Meet This requirement on all street frontages. Air conditioning units are NOT PERMITTED within REQUIRED Side or Rear yards. Screen ALL Mechanical Units & Service Structures to top of unit including utility features and air conditioning units. Contact PLANNING DIVISION 410-4600 ENCOURAGE DRIVEWAY TO SIDELOAD GARAGE BE AT LEAST 25 FEET FROM GARAGE DOOR OPENING FOR EASE OF MANEUVERING. Fee summary Charged Paid Credited Due Permit Fee Total 290.00 .00 .00 290.00 Plan Check Total .00 .00 .00 .00 Grand Total 290.00 .00 .00 290.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. Inspection Type(s): ZONING INSPECTION FORM Zoning/Landscape Land Use and Long Range Planning Commercial ? Code Enforcement Residential 5800 Shier-Rings Road; Dublin OH 43016 Sign ? CITY OF DUBLIN ' Other ? Telephone/TDD 614-410-4600 Dublin Planning Fax 614-410-4747 Dublin Inspection Line 614-410-4680 Permit 7+ 2-00 81 0 Project Name : ~ t dt~x ar 7 Project Address: 4~ 000 J 0eA 14 t 6A< f4 Contact Person: 77e Contact Phone: S O 1) Approved Landscape Plan & ROA YES NOgn installed as approved YES ~l' O 2) Plans , Checklist & Permit on Site YES NO -7r-Parking spaces, number & striped .D- YES 3) Lighting installed per plan YES NO W~andicap spaces properly signed YES NO 4) Landscape installed per plan YES NO rking islands 7 foot minimum YES'/ TO 5) Mechanicals screened per code YES,,?NO 10) Meet residential appearance code Zoning Approved Zoning Conditionally Approved (See Comments) ? Zoning Disapproved (See Comments) ? Date of Inspection Inspected B COMMENTS t .w ,mss o 7 5 (M°4.0, jet,. j L4 6., '5 x 44J o fJ EA , ( ~v'C c Lt d /`x' t _ 14 f t G y q Zoning Inspection Form PLA-120 Date 08/12/04 Page 1 - ` Residential Heat Loss and Heat Gain Calculation 5/18/2007 In accordance with ACCA Manual J Report Prepared By: Air Systems Heating and Cooling For: ALEXANDRA BUILDING COMPANY 549 BALLANTRAE DUBLIN, OHIO Design Conditions: - DUBLIN Indoor: Outdoor: Summer temperature: 75 Summer temperature: 95 Winter temperature: 72 Winter temperature: 0 Relative humidity: 50 Summer grains of moisture: 100 Daily temperature range:Medium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Whole House 4,548 sq.ft. 26,163 7,377 33,540 83,079 (3tons ) First Floor 13,009 4,349 17,358 41,993 All Rooms 1,474 sq.ft. 13,009 4,349 17,358 41,993 Infiltration 3,082 3,429 6,511 19,415 People 4 1,200 920 2,120 0 Miscellaneous 1,200 0 1,200 0 Fireplace 0 0 0 10,446 Floor 1,474 sq.ft. 0 0 0 0 S Wall 332.4 sq.ft. 588 0 588 1,795 Window 23.3 sq.ft. 746 0 746 545 Glassdoor 28.3 sq.ft. 566 0 566 697 E Wall 422 sq.ft. 747 0 747 2,279 Window 5 sq.ft. 196 0 196 117 Window (2) 5 sq.ft. 196 0 196 117 W Wall 403.7 sq.ft. 715 0 715 2,180 Window 23.3 sq.ft. 1,491 0 1,491 545 Window (2) 5 sq.ft. 320 0 320 117 N Wall 301.1 sq.ft. 533 0 533 1,626 Window 23.3 sq.ft. 443 0 443 545 Window (2) 11.3 sq.ft. 215 0 215 264 Window (3) 30.3 sq.ft. 576 0 576 709 Door 18 sq.ft. 195 0 195 596 Second Floor 12,128 2,627 14,755 30,374 2 - d E862-L2t -O*L 003 1 9W I1U3H SW31SAS 2I I d e96:90 LO ST ReW 07/10/2007 07:56 5520235 PAGE 01 l3 ~ S ]ac. •at~ (Aw raw" mw, 1. low woo RN' om* N4Y mw ssrlp x ° :r i~. 6r 4VF1M = dm* i nhWA1M 4 0 0 1- TOhI1IYtlIfr pOr br 00 el a X 0 ~ ~e a ~+•+oowq... NIrnIBw otaprrrnMSl~ ~ erd~, Use torus qlpfte opoh We at 3 wM W wpMM ft b) Srdibpll of w ~M avMbnane load to wails ~ C 0 ° t 3- Al fmd or Iwo- ry apps b) [ (000. wag ovemaklm dryr Y fYrlor Aotrt MlEC 1sWSi SKW, o1G) Nlnupyl~ r~ ?000 B. told bparb>w IoiQ in w 4, WYwr hem*. kwnqfta p TOM wpm* kow of h*wam 11- &*k'W of 1.3b, 3 S 4 37WO 0 a a bammw s, adurr+oonK Ma (-n x s walw. 0 0. F** %OM wtMb 0 ion 1 :,,,aor- • T9W wasof howt~ 7. aletodldQ 06 rarlrs 27600 0 few, (?msommaw © a a TOM of hWkMr and bUSIMt hM6V bads S. llne l{T nn>.ir 0 4Q7i 11040 0 0 0 ' Ifim a t IMpar tq.tl a.o.a~ hwt ar lyC class w.~ eooo Waftbe chym) IQ Twl dMllghr blld b1 7Q dobrl arde, llb. andtlb} 3900 a 0 0 +.ow toads waft 11, Tool wets for prbnw,t buldk p r WAL L*A0 IN VMrFS pWOM by VOLTAGE 11 TOM MMwftrbLddhr, Ioruw awwPhm 1oWws* 0 Awgw or g4w ft omw 137AP 0 0 0 fxar2gN, b~ q,~ 1240m 0 a °r~~P~sslbrApttotld: 1saa08 0 q 0 N BJrs ELECTRICAL SERVICE 10428APPLETON Ro JOHNSTOWN, OHIO 43031 967-8 i34 ~e Rock r41 I \0 t'+T ~x~ GCnnn')C m!~ T. ..1.. /Tl T1 i~t _L "/tn/1nn7 '7_Al T1~ T.. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 These drawings have been reviewed for and shall comply with the 2004 Edition of the Residential Code of Ohio. PLAN REVIEW CHECKLIST ~ Application No. 0 010,3 tq m c m n % a V a E C Date Reviewed , c 1- 0 c m V c Reviewed By CL Z c r_ a Plan Reviewer's Comments & Notes o. Q _Itl Approved o p Z A m OC OBBC Model Energy Code 114 -1 MEC Check worksheet required Manual J/Electric Loads lef Houses over 3,000 Sq. Ft. Ordinance Stair Risers & Treads 7 3/4" max. riser 10" min. treads and 68* headroom R303.6 Stairway illumination R311 Handrails & Guards R312 R303.1 Light & Ventilation Schedules Schedules Required on Plans, houses, additions and sunrooms R306 Sanitation - Fixture Clearance R307 - Figure 307.2 R308 Required Safety Glazing R309 Attached Garage Fire Separation 13/8" s. c. or 20 min. door and 518" gyp. Bd. Type V on all common walls per City Ordinance R310 Bedroom Emergency Egress 5.7 sq. ft. (24" net hgt. 20" net width) max. window still lhgt. Of 44" a.ff. R311 Eats R311.4.2.1 Interior Doors Bath 2'4*x 68", habitable space 2/6wx 68 (min) R311.4.3 Landings Minimum X x 3' R311.2.2 Understair Protection 112" gyp. Bd. Type X" R313 Smoke Detector Locations Bsmt/hallway/bedrooms wired to prime electric/battery pack - upAnterconnected Ordinance Carbon Monoxide Detector Outside sleeping areas R317 Foam plastic separation R401.4.1 Soil bearing capacity Use 1,500 psf R403 Footing/pier/pad size & location(s) R403.1.6 Foundation anchorage 112" anchor bolt @ 6 0" oc,7" into masonry & concrete R404 Foundation wall sizes & reinforcements Stamped engineered foundation plan required for houses and additions R405 Foundation drainage systems R406 Damproofing or waterproofing R502.3 Floor joist(s) allowable spans Lumber specifications required on drawings R502.5 Allowable girder spans Per Tables R502.5(1) & R502.5(2) R502.6 Bearing 1 112" for wood & steeU 3" for masonry & concrete R502.11.4 Floor Trusses Engineered design required at Frame inspection PLAN REVIEW CHECKLIST o ' a ~ ~ m w o o m o a Plan Reviewer's Comments & Notes G Z m a a U m v o z o oc R503 Floor sheathing R(402.2) Concrete floors on ground R 506 R602 Wood wall framing R602.7 Headers Tables 502.5(1) & R502.5(2) R602.10 Wall bracing f 4603 Steel wall framing R703.7 Masonry veneer Table 703.4 R802 Wood roof framing Show truss profiles on roof plan R802.3 Framing details Rafter ties, joist not perpendicular to rafters R802.4 Allowable ceiling joist spans R802.5 Allowable rafter spans R802.10 Roof trusses Stamped engineered roof trusses required at framing inspection R807.1 Attic access 22'x 30- R1001 Masonry chimneys Spark arrestor with rain capper City Ordinance R1002 Facto built chimneys Spark arrestor with rain cap R1003 Masonry fireplaces Table 1003.1 & Figure 1003.1 R1004 Factory built fireplaces R1005 Exterior air supply M1701 Combustion air 50 cubic per 1,000 btu/h R602.3.1 Stud size & spacing Table R602.3.1(2) Front & Back Form Revised 04/12/05 D7. X008/0 Permit # TL•o7 Rob Permit Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: Ballantrae Spec Report Date: 04/26/07 Data filename: \\M2server\company\Clients\Builders\Alexandra Building Company\Ballantrae Lot 549\CALCS\Ballantrae Lot 549.rck Energy Code: 2003 IECC Location: Dublin (Franklin), Ohio Construction Type: Single Family Glazing Area Percentage: 12% Heating Degree Days: 5719 Construction Site: Owner/Agent: Designer/Contractor: Ballantrae Lot 549 Troy Miller Greg Miller Dublin, OH Alexandria Building Company M2 Design Group, LLC 7140 North High Street Worthington, OH 43085 614-844-5855 Compliance: Passes Maximum UA~ 733 Your Home UA: 666 - 9.1% Better Than .Code (UA) Ceiling: Flat Ceiling or Scissor Truss: 2105 30.0 0.0 74 2x4 Wall 1st: Wood Frame, 16" o.c.: 1587 13.0 0.0 112 Windows: Wood Frame:Double Pane with Low-E: 168 0.300 50 Doors: Solid: 18 0.270 5 Doors: Glass: 40 0.300 12 2x6 Wall 1st: Wood Frame, 16" o.c.: 80 19.0 0.0 3 Windows: Wood Frame:Double Pane with Low-E: 13 0.300 4 Door: Solid: 20 0.270 5 2x4 Wall 2nd: Wood Frame, 16" o.c.: 1810 13.0 0.0 136 Windows: Wood Frame:Double Pane with Low-E: 155 0.300 47 2x6 Wall 2nd: Wood Frame, 16" o.c.: 80 19.0 0.0 3 Windows: Wood Frame:Double Pane with Low-E: 31 0.300 9 Basement Wall: Masonry Block with Empty Cells: 1444 0.0 10.0 185 Windows: Vinyl Frame:Double Pane with low-E: 21 0.300 6 Floor Over Garage: All-Wood Joist/Truss:Over Unconditioned 320 19.0 0.0 15 Space: Furnace: Forced Hot Air: 90 AFUE Air Conditioner: Electric Central Air: 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist V_r uo Bui I esigner Company Name Date Ballantrae Spec Page 1 of 5 REScheck Software Version 3.7.3 Inspection Checklist Date: 04/26/07 Ceilings: ? Ceiling: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above-Grade Walls: ? 2x4 Wall 1st: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: ? 2x6 Wall 1st: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: ? 2x4 Wall 2nd: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: ? 2x6 Wall 2nd: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Basement Walls: ? Basement Wall: Masonry Block with Empty Cells, 8.7' ht/8.0' bg/1.0' insul, R-10.0 continuous insulation Comments: Exterior insulation must have a rigid, opaque, weather-resistant protective covering that covers the exposed (above-grade) insulation and extends at least 6 in. below grade. Windows: ? Windows: Wood Frame:Double Pane with Low-E, U-factor: 0.300 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ? Windows: Wood Frame:Double Pane with Low-E, U-factor: 0.300 For windows without labeled 1.1-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ? Windows: Wood Frame:Double Pane with Low-E, U-factor: 0.300 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ? Windows: Wood Frame:Double Pane with Low-E, U-factor: 0.300 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ? Windows: Vinyl Frame:Double Pane with Low-E, U-factor: 0.300 For windows without labeled 1-1-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ? Doors: Solid, U-factor: 0.270 Comments: ? Doors: Glass, U-factor: 0.300 Bailantrtrae Spec Page 2 of 5 Comments: ? Door: Solid, U-factor: 0.270 Comments: Floors: ? Floor Over Garage: All-Wood Joist/Truss:Over Unconditioned Space, R-19.0 cavity insulation Comments: Heating and Cooling Equipment: ? Furnace: Forced Hot Air: 90 AFUE or higher Make and Model Number: ? Air Conditioner: Electric Central Air: 13 SEER or higher Make and Model Number: Air Leakage: ? Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ? Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-IC rated, the fixture must be installed with a 3" clearance from insulation. Skylights: ? Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19. Vapor Retarder: ? Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: ? Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ? Materials and equipment must be identified so that compliance can be determined. ? Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ? Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ? Supply ducts in unconditioned attics or outside the building must be insulated to R-8. ? Return ducts in unconditioned attics or outside the building must be insulated to R-4. ? Supply ducts in unconditioned spaces must be insulated to R-8. ? Return ducts in unconditioned spaces (except basements) must be insulated to R-2. ? Where exterior walls are used as plenums, the wall must be insulated to R-8. ? Insulation is not required on return ducts in basements. Duct Construction: ? Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. ? All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ? The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ? Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: ? Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ? Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Bailantrae Spec Page 3 of 5 i ? Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ? All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ? HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Ballantrae Spec Page 4 of 5 r Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature (°F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range("F) 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Ballantrae Spec Page 5 of 5