07201627 Permit File Office CITY OF DUBLIN Y COV Building Standards • 5800 Shier-Rings Road • Dubl m' hib 43016 NOV 2 0 2007 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 NOV 2 c, 2007 WTFD: (614) 652-3920 "r 4 a BUILDING DIVISION , CITY OF DUBLIN FIRE PROTECTION PERMIT APPLICATION Application Date 1 IBldg. ANp# Fire Protection App. # 07- 9-01 (0)1 ` PROJECT INFORMATION w~ Project Address c U I~..NAA J L`1[ k Project Name !1i Owner/Tenant Contact Name Telephone APPLICANT INFORMATIG - FY A, p 4 Fire Protection Contract J ~ -T-L>dZ- SOIT( N NDA L- pE "J Address 'I-')rulr? ik ~ X60 Telephon ( og)_ - scl- ~atS ? State Certificate umber 004 2-Ig S Dublin Regi tration Number ' Installer Name P~.il An?[)A~.~ State Certificate Number,54- ai - )2-iq SCOPE OF WORK ~ / (Mark One) New 1/ Replace Repair Alteration FIRE DETECTION AND ALARM SYSTEM (Number of Each) Detectors 2 Strobes IC2 Horns Fire Alarm Boxes 1 Other SUPPRESSION SYSTEM (Number of Each}, Standpipes On Site Water Piping Sprinkler Heads Limited Area Other FEES FIRE DETECTION OR SUPPRESSION PERMIT PROCESSING FEE $60.00 LOW VOLTAGE PERMIT (DETECTION ONLY) $30.00 Minimum fee plus $20.00 each 1,000 sq ft or fraction thereof over 1,000 sq ft OUTSIDE PLAN REVIEW SERVICES (EXAMINER'S FEE AS CHARGED) 3010 00 STATE SURCHARGE (3%) TOTAL FEE DUE 3~CU. O This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. This permit conveys no right to open any street, alley or sidewalk or any part eof, nor to make any connection to a water main. Signature of Licensed Contractor DATE 1? i~`~ Print Name *4"F J1gr-t~ i ~ DATE lc+ FOR OFFICIAL USE ONLY Review Comments: ,V The /'ey1Sec! YCI%e a'/arm ~ao~rinerrfs~~rc~u~~i~9s~eef W'7skix?*>n Tow~zs6i o file OPOUr~ir~n f ~i'ora/ X Fire Department: Date: a?~o8 08 Plans Examiner: l,~> Date: Issued by CBO: Date: l~Zi/D- CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00201627 Date 1/25/08 Revision number . . . . . . . 1 Property Address . . . . . . 6365 EMERALD PKY Parcel Number: 273-004511 Alternate Address: TUTOR TIME LEARNING Tenant nbr, name . . . . . . TUTOR TIME DETECTION Application type description FIRE PROTECTION Property owner . . . . . . . EMERALD ARC, LLC Contractor . . . . . . . . . TITAN POWER SOLUTIONS Permit . . . . . . FIRE DETECTION PERMIT Additional desc . . Permit Fee . . . . 60.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 60.00 Special Notes and Comments CONTACT WASHINGTON TOWNSHIP FIRE PREVENTION FOR INSPECTIONS AT 766-0857 Other Fees . . . . . . . . . OUTSIDE PLAN REVIEW 300.00 SURCHARGE FEE - BLDG 9.00 SURCHARGE FEE - FIRE 1.80 Fee summary Charged Paid Credited Due Permit Fee Total 60.00 .00 .00 60.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 310.80 .00 .00 310.80 Grand Total 370.80 .00 .00 370.80 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. if POWER SOLUTIONS TUTOR TIME DAY CAR~Afi1Afw0 January 3, 2008 City of Dublin Building Department Attn: Jeff Tyler, Director 5800 Shier Rings Road R E I E Dublin, OH 43016 AN 0 3 2008 Re: Tutor Time DayCare - Fire Alarms Permit #07-201297jLjNC DIVISION 4 ~;r DUBLIN Good morning Mr. Tyler, Per the correction request #1 from December 14 of 2007, please accept this letter as a response to resolve the concerns noted by Mr. Michael Boryca, Plans Examiner. Item #1 (013C 105.3.1.4) Automatic fire protection system construction documents Mr. Danny Popp is the architect of record for this project. However, Brian Vandal has assisted in the design of the fire protection system for this building. In additional to being a certified fire alarm system installer, Brian Vandal is also a registered professional electrical engineer in Ohio, with the certification number of 67512. In addition, Brian is a master electrician, with the state of Ohio certification of 29458. Item #2 (06C 907.1.1) Construction Documents Specification cut sheets for the pull stations, strobes, horn/strobes, and the fire alarm control panel will be submitted with this letter for further review. E:pouL Brian Vandal, PE 5766 Westbourne ave. bvandal antitanps.com 614-759-9015: Tel Columbus, Ohio 43213 614-759-9016: Fax CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Applications #07-201627(1) January 21, 2008 PLAN APPROVAL FIRE ALARM/DETECTION SYSTEM THIS IS NOT A BUILDING PERMIT. IT IS A RECORD OF OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT. Re: Tutor Time Applicant: Titan Power Solutions, 6365 Emerald Parkway (614) 759-9015 Fire Alarm/Detection Fire Protection Permit No: 07-201627(1) The Revised Fire Alarm Documents with Transmittal Letter dated January 3, 2008, submitted with the Fire Protection Permit Application, for the captioned project, has been reviewed for compliance with the provisions of the 2007 Ohio Building Code (OBC). The review was based upon the following criteria: Use: E, Educational Day Care Facility. Construction: VB, Combustible / Un-Protected Construction Area: 10,500 SF Total Occupancy: 361 Total Notes: New slab on grade building with wooden walls and roof framing. Improvements include new partitions with finishes, doors and hardware with plumbing, HVAC, electrical lighting and power requirements. A manual fire alarm system is required and proposed for this building. The Fire Alarm Drawing is sealed by Danny D. Popp, Ohio registered architect no. 7978. The fire protection contractor is Titan Power Solutions, Certification number OH 29458and the Application identifies the fire alarm systems Installer as Brian Vandal, Ohio State Certification Number 54-21-1214, all to comply with the requirements of OBC Section 105.3 and have been reviewed, therefore, in accord with OBC section 105.3.1.4. This PLAN APPROVAL for the fire protective signaling system only, is issued by the City of Dublin, Division of Building Standards, in accordance with Section 106.3.1 OBC. For the information of the Applicant the following item(s) are required for code compliance, but are not necessarily covered in detail in the construction documents This list is a reminder to the design professional and contractors of issues which are to be satisfactorily dealt with in the field: 1. The certificate of approval of fire protection plans shall be posted in a conspicuous location outside of the building or in the front part of the premises on which is, or will be, located the approved building or equipment. The owner and the contractor shall, so far as possible, preserve and keep said certificate until the completion of the work to which the approved construction documents relate; Section 105.7.2 OBC. 2. The proposed construction shall conform to the requirements of Chapter 11 OBC and the "Americans with Disabilities Act Accessibility Guidelines" (ADAAG). City of Dublin FIRE PROTECTION PLAN REVIEW 07-201627(1) Tutor Time - Fire Alarm / Detection System January 21, 2008 07-201627(1) Page 2 3. Provide a record of completion for each completed fire alarm system in accordance with Section 907.17 and NFPA 72 Completion Documents. 4. Upon completion of the fire protective signaling system, all alarm-initiating devices and circuits, alarm- indicating appliances and circuits, supervisory-signal initiating devices and circuits, signaling line circuits, and primary and secondary power supplies shall be subjected to a 100 percent acceptance test in accordance with NFPA 72A and 72E listed in Chapter 35; Section 907.16 OBC. 5. OBC 907 Acceptance testing: When the installation of the detectors is complete, each detector and all interconnecting wiring for multiple-station detectors shall be subject to a 100-percent acceptance test in accordance with the household fire warning equipment provisions of NFPA 72 listed in Chapter 35. 6. No electrical work (conduits, cables or other electrical apparatus) may be covered or concealed without visual inspection and approval by the electrical field inspector as per OBC 109. 7. All electrical work will comply with the requirements of Article 27 OBC and the National Electric Code NFPA 70, OBC approved edition and is subject to the approval of the electrical inspector, in accordance with Section 109 of the OBC. TO REQUEST AN APPEAL HEARING, YOU MUST send a written request, listing the items to be appealed and the relief sought and on copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin, Ohio 5800 Shier Rings Road Dublin, Ohio 43017-1236 THE SIGNING OF THIS DOCUMENT IS AN AGREEMENT THAT YOU WILL COMPLY WITH ALL ITEMS LISTED HEREIN. THE COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF ALL ITEMS LISTED HEREIN. Reviewed and signed, Michael A. Boryca, Architect/Plan xaminer J fr,Chief uilding O fficial City of Signature - Architect, Engineer, Contractor Da or Owner ~2 p,J V (Zxws . - Print Name and Title as Signed c: Washington Township Fire Department City of Dublin FIRE PROTECTION PLAN REVIEW 07-201627(1) • • VNTIES OF WASHINGTON TOWNSHIP C~ FIRE DEPARTMENT 6200 Eiterman Road, P.O. Box 3248 •FRANY, Dublin, Ohio 43016 mum", 614-652-3920 • Fax 614-766-2507 Date: 4 Oc~F'ir~6~r a6r7 To: Jeff Tyler, Director City of Dublin Division of Building Standards 5800 Shier Rings Road Dublin, Ohio 43016 Re: Washington Township's Fire Department Plan Review Permit 07-/Ea77 Proj ect: Location: ~s Err~r~~/~ Received: Ar /yoyt-lnho- 'AMI Review Comments: ~is9Dai'odR~. fi/cam 1:771/rI~7 /~C/ 110S i - u2ss - Reviewed By: Trustees Gene Bostic • Denise Franz King • Charles Kranstuber Fiscal Officer Joyce E. Robinson Chief Allan Woo CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Applications #07-201627 December 14, 2007 CORRECTION REQUEST #1 FIRE ALARM/DETECTION SYSTEM THIS IS NOT A BUILDING PERMIT. IT IS A RECORD OF OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT. Re: Tutor Time Applicant: Titan Power Solutions, 6365 Emerald Parkway (614) 759-9015 Fire Alarm/Detection Fire Protection Permit No: 07-201627 The Fire Alarm Documents dated 11/12/07, submitted with the Fire Protection Permit Application, for the captioned project, has been reviewed for compliance with the provisions of the 2007 Ohio Building Code (OBC). The review was based upon the following criteria: Use: E, Educational Day Care Facility. Construction: VB, Combustible / Un-Protected Construction Area: 10,500 SF Total Occupancy: 361 Total Notes: New slab on grade building with wooden walls and roof framing. Improvements include new partitions with finishes, doors and hardware with plumbing, HVAC, electrical lighting and power requirements. A manual fire alarm system is required and proposed for this building. The Fire Alarm Drawing is sealed by Danny D. Popp, Ohio registered architect no. 7978. The fire protection contractor is Titan Power Solutions, Certification number NOT provided and the Application identifies the fire alarm systems Installer as Brian Vandal, Ohio State Certification Number 54-21-1214, all to comply with the requirements of OBC Section 105.3 and have been reviewed, therefore, in accord with OBC section 105.3.1.4. The plans for the project referenced above have been reviewed and found to be incomplete and/or to contain violations of the Ohio Building Code [OBC]. As a result, the City of Westerville, Planning and Development Department is unable to issue plan approval at this time as provided for in Sections 3781 and 3791 of the ORC. This CORRECTION LETTER is not a disapproval of the plans, but is a request for clarification and/or modification of the following items. Part I of this notice serves as a Correction Letter, allowing you to resubmit revised plans and/or additional information as noted. PART L CORRECTION LETTER The following item(s) shall be brought into full conformance with the 2007 OBC prior to the issuance of final plan approval: City of Dublin FIRE PROTECTION PLAN REVIEW 07-201627 Tutor Time - Fire Alarm / Detection System December 14, 2007 07-201627 Page 2 1. OBC 105.3.1.4 Automatic fire protection system construction documents. Construction documents for fire protection systems shall: When submitted under the signature of an individual certified under Section 3781.105 of the Revised Code, be processed in the same manner as construction documents submitted under the signature of a registered design professional. Any statistical data, reports, explanations, plan description, or information that would not also be required for a similar submission by a registered design professional need not be submitted by a certified designer. Please verify. Is Mr. Danny D. Popp, the individual responsible for the "Design " of this fire protection system? If not, please submit information on the individual Certified under Section 3781.105 of the Revised Code who is responsible for the "Design " of this Fire Alarm System. The Systems Designer shall hold a Certification pursuant to the Ohio Board of Building Standards (Section 3781.105) or be a registered design professional possessing the proper technical training andl'or experience in the engineering of such fire protection systems. Information received with this application was not clear on this, and the Fire Protection Application did not list any certification number for the Fire Protection Contractor. Please verify both issues for the fire protection systems `Designer' of this system, and the State Certification Number for the fire protection contractor. Please know that the certified individual responsible for installing the system has been identified. We are trying to verify who the Designer of this system is and what the state certification number is for Titan Power Solutions. 2. OBC 907.1.1 Construction documents. Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Construction documents shall include, but not be limited to, all of the following: L A floor plan which indicates the use of all rooms. 2. Locations of alarm-initiating and notification appliances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and sizes. 8. Voltage drop calculations. 9. Manufacturers, model numbers and listing information for equipment, devices and materials. 10. Details of ceiling height and construction. 1. The interface of fire safety control functions Please submit information demonstrating compliance with Item Nos. 9 and 10 of this code section, so that we may continue our review of this application. Specification cut-sheets were ONLYprovided on the fire alarm control panel. Please submit specification cut-sheets for all equipment/devices, as proposed for this application so that we may continue our review. This review does not preclude the necessity to conform with provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rest with the registered design professional, the tenant and the owner. Plan Approval will be valid only upon receipt by the City of Dublin, Division of Building Standards, of one signed copy of this addendum. City of Dublin FIRE PROTECTION PLAN REVIEW 07-201627 Tutor Time - Fire Alarm / Detection System December 14, 2007 07-201627 Page 3 TO REQUEST AN APPEAL HEARING, YOU MUST send a written request, listing the items to be appealed and the relief sought and on copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin, Ohio 5800 Shier Rings Road Dublin, Ohio 43017-1236 Reviewed and signed, f Building Official Michael A. Boryca, Architect/Plans aminer effrey flin,Ohlo (6 x#68 City of Signatur _ A r ct, Engineer, Contractor Date or Owner Print: Name and Title as Signed q* &7512 j- c: Washington Township Fire Department MAB:Iwb City of Dublin FIRE PROTECTION PLAN REVIEW 07-201627 architecture! memorandum invoice #07-201627 - 2 OHIO INCORPORATED 454 East Main Street Suite 236 Columbus, Ohio 43215-5380 614.488.4009 fax.488.4005 January 21, 2008 City of Dublin Contract No. PS 01-21-13 Employer Identification No. 31-1413248 City of Dublin Division of Building Standards 5800 Shier-Rings Road Dublin, Ohio 43016 Attention: Mr. Jeffrey S. Tyler, Chief Building Official Plan Review Services for: Tutor Time - Fire Alarm/Detection System Revisions 6365 Emerald Parkway PLAN APPROVAL Permit No. 07-201627(1) Labor Cost: Total Number of Hours to be Charged @ $60.00/Hour: 1.0 • Review Time: 0.5 • Administration Time: 0.5 TOTAL BILLING THIS INVOICE $60.00 This memorandum invoice is being sent as reference for you to prepare the necessary fees for the applicant to pay. The time spent on this review will be submitted for payment at the end of the month with our usual invoicing. Should you have any questions or comments concerning this review, please don't hesitate to contact me. Thank you for the opportunity to be of service. Cordially, architecture! r~); °'E1 1 Michael A. Boryca, Architect Plans Examiner 4P001794 CITY OF DUBLIN COVED Building Standards • 5800 Shier-Rings Road • Du [-4'11680 EQ3016 w>{ Phone: (614) 410-4670 • Inspection Line: (614) 41 NOV 2 9 2007 NOV 2 0 2007 WTFD: (614) 652-3920 BUILDING DIVISION prC;h!frec t,u CITY OF DUBLIN FIRE PROTECTION PERMIT APPLICATION OmO_iLr_,+L~Y„+_r Application Date 111 JMJD~- Bldg. App. # 01",20 1 ~1 Fire Protection App. # PROJECT INF O Project Address Project Name7N . ii c t Owner/Tenant Contact Name Telephone APPLICANT INFORMATI Fire Protection Contract t i'"a- Address U U o 04%K. i Telephon - !S State Certificate umber Dublin Reg, tration Number ' - ' quqgi Installer Name `M'me -1 State Certificate Number- I -121 C1~~ SCOPE OF WORK (Mark One) New - dSSI A~G~ l Repair Alteration FIRE DETECTION, )er of Each) 2'J Detectors AW s Fire Alarm Boxes 3-1 Other c o SUPPRESSION Sly Standpipes _ Sprinkler Heads Limited Area Other FEES FIRE DETECTION OR SUPPRESSION PERMIT PROCESSING FEE $60.00 LOW VOLTAGE PERMIT (DETECTION ONLY) $30.00 Minimum fee plus $20.00 each 1,000 sq ft or fraction thereof over 1,000 sq ft OUTSIDE PLAN REVIEW SERVICES (EXAMINER'S FEE AS CHARGED) STATE SURCHARGE (3%) TOTAL FEE DUE This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. This permit conveys no right to open any street, alley or sidewalk ortny -part~t eof, nor to make any connection to a water main. Signature of Licensed Contractor DATE I igtn- DATE Print Name w FOR OFFICIAL USE ONLY Review Comments: Fire Department: Date: Plans Examiner: Date: Issued by CBO: Date: architecture! memorandum invoice #07-201627 -1 OHIO INCORPORATED 454 East Main Street Suite 236 Columbus, Ohio 43215-5380 614.488.4009 fax.488.4005 December 14, 2007 City of Dublin Contract No. PS 01-21-13 Employer Identification No. 31-1413248 City of Dublin Division of Building Standards 5800 Shier-Rings Road Dublin, Ohio 43016 Attention: Mr. Jeffrey S. Tyler, Chief Building Official Plan Review Services for: Tutor Time - Fire Alarm/Detection System 6365 Emerald Parkway CORRECTION REQUEST LETTER #1 Permit No. 07-201627 Labor Cost: Total Number of Hours to be Charged @ $60.00/Hour: 4.0 • Review Time: 2.5 • Administration Time: 1.5 TOTAL BILLING THIS INVOICE $240.00 This memorandum invoice is being sent as reference for you to prepare the necessary fees for the applicant to pay. The time spent on this review will be submitted for payment at the end of the month with our usual invoicing. Should you have any questions or comments concerning this review, please don't hesitate to contact me. Thank you for the opportunity to be of service. Cordially, architecture iAit ~ Michael A. Boryca, Architect Plans Examiner #P001794 CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Applications #07-201627 December 14, 2007 CORRECTION REQUEST #1 FIRE ALARM/DETECTION SYSTEM THIS IS NOT A BUILDING PERMIT. IT IS A RECORD OF OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT. Re: Tutor Time Applicant: Titan Power Solutions, 6365 Emerald Parkway (614) 759-9015 Fire Alarm/Detection Fire Protection Permit No: 07-201627 The Fire Alarm Documents dated 11112/07, submitted with the Fire Protection Permit Application, for the captioned project, has been reviewed for compliance with the provisions of the 2007 Ohio Building Code (OBC). The review was based upon the following criteria: Use: E, Educational Day Care Facility. Construction: VB, Combustible / Un-Protected Construction Area: 10,500 SF Total Occupancy: 361 Total Notes: New slab on grade building with wooden walls and roof framing. Improvements include new partitions with finishes, doors and hardware with plumbing, HVAC, electrical lighting and power requirements. A manual fire alarm system is required and proposed for this building. The Fire Alarm Drawing is sealed by Danny D. Popp, Ohio registered architect no. 7978. The fire protection contractor is Titan Power Solutions, Certification number NOT provided and the Application identifies the fire alarm systems Installer as Brian Vandal, Ohio State Certification Number 54-21-1214, all to comply with the requirements of OBC Section 105.3 and have been reviewed, therefore, in accord with OBC section 105.3.1.4. The plans for the project referenced above have been reviewed and found to be incomplete and/or to contain violations of the Ohio Building Code [OBC]. As a result, the City of Westerville, Planning and Development Department is unable to issue plan approval at this time as provided for in Sections 3781 and 3791 of the ORC. This CORRECTION LETTER is not a disapproval of the plans, but is a request for clarification and/or modification of the following items. Part I of this notice serves as a Correction Letter, allowing you to resubmit revised plans and/or additional information as noted. PART I. CORRECTION LETTER The following item(s) shall be brought Into full conformance with the 2007 OBCprior to the issuance of final plan approval. City of Dublin FIRE PROTECTION PLAN REVIEW 07-201627 Tutor 'Time - Fire Alarm / Detection System December 14, 2007 07-201627 Page 2 1. OBC 105.3.1.4 Automatic fire protection system construction documents. Construction documents for fire protection systems shall: When submitted under the signature of an individual certified under Section 3781.105 of the Revised Code, be processed in the same manner as construction documents submitted under the signature of a registered design professional. Any statistical data, reports, explanations, plan description, or information that would not also be required for a similar submission by a registered design professional need not be submitted by a certified designer. Please verify. Is Mr. Danny D. Popp, the individual responsible for the "Design" of this fire protection system? If not, please submit information on the individual Certified under Section 3781.105 of the Revised Code who is responsible for the "Design" of this Fire Alarm System. The Systems Designer shall hold a Certification pursuant to the Ohio Board of Building Standards (Section 3781.105) or be a registered design professional possessing the proper technical training and/or experience in the engineering of such fire protection systems. Information received with this application was not clear on this, and the Fire Protection Application did not list any certification number for the Fire Protection Contractor. Please verify both issues for the fire protection systems `Designer' of this system, and the State Certification Number for the fire protection contractor. Please know that the certified individual responsible for installing the system has been identified. We are trying to verify who the Designer of this system is and what the state certification number is for Titan Power Solutions. 2. OBC 907.1.1 Construction documents. Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Construction documents shall include, but not be limited to, all of the following: 1. A floor plan which indicates the use of all rooms. 2. Locations of alarm-initiating and notification appliances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and sizes. 8. Voltage drop calculations. 9. Manufacturers, model numbers and listing information for equipment, devices and materials. 10. Details of ceiling height and construction. 11. The interface of fire safety control functions Please submit information demonstrating compliance with Item Nos. 9 and 10 of this code section, so that we may continue our review of this application. Specification cut-sheets were ONLYprovided on the fire alarm control panel. Please submit specification cut-sheets for all equipment/devices, as proposed for this application so that we may continue our review. This review does not preclude the necessity to conform with provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rest with the registered design professional, the tenant and the owner. Plan Approval will be valid only upon receipt by the City of Dublin, Division of Building Standards, of one signed copy of this addendum. City of Dublin FIRE PROTECTION PLAN REVIEW 07-201627 Tutor Time - Fire Alarm / Detection System December 14, 2007 07-201627 Page 3 TO REQUEST AN APPEAL HEARING, YOU MUST send a written request, listing the items to be appealed and the relief sought and on copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin, Ohio 5800 Shier Rings Road Dublin, Ohio 43017-1236 Reviewed and signed, Michael A. Boryca, Architect/Plans aminer Jeffrey S. Tyler, Chief Building Official (614) 488-4009 City of Dublin, Ohio Signature - Architect, Engineer, Contractor Date or Owner Print Name and Title as Signed c: Washington Township Fire Department MAB:Iwb City of Dublin FIRE PROTECTION PLAN REVIEW 07-201627 • aAnES pf, WASHINGTON TOWNSHIP G FIRE DEPARTMENT 6200 Eiterman Road, P.O. Box 3248 fl7ANKN Dublin, Ohio 43016 614-652-3920 • Fax 614-766-2507 Date: //912ae nier a?4r7 To: Jeff Tyler, Director City of Dublin Division of Building Standards 5800 Shier Rings Road Dublin, Ohio 43016 Re: Washington Township's Fire Department Plan Review Permit o7 ,31A7 Project: 7u7~7r rline Location: 6365 Elnel-,Va AY Received: o7p /1~~yPrn6~- 777 Review Comments: Dis~oaro~~ T! fire g/grin di,-;7" 5 J-D 4ef hosh~,7.726,7 /76-7" /YIN /r'e l lw?7s veil ey- /eme-r wq~~r w Xr fie G Reviewed By: G~'' ie /yl~~.sf>~~ Trustees Gene Bostic • Denise Franz King • Charles Kranstuber Fiscal Officer Joyce E. Robinson Chief Allan Woo 'r JJJ e ~ t ,rn!i_ ,2z Photoelectric Smoke Detectors System Sensor's i3" series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles: installation E IVC D ease, intelligence, and instant inspection. JAN 0 3 2008 BUILDING DIVISION CITY OF DUBLIN Features Installation ease. The i3 line redefines installation ease with its Plug-in detector line, mounting base included plug-in design. This allows an installer to pre-wire the bases included with the heads, The large wire entry port and in-line terminals Large wire entry port provide ample room for neatly routing the wiring inside the base. In-line terminals with SEMS screws The base accommodates a variety of back box mounting methods, Mounts to octagonal and single-gang backboxes, 4-square as well as direct mounting with drywall anchors.To complete the barkboxes, or direct to ceiling installation, i3 heads plug in to the base with a simple Stop-Drop 'N Lock' action. Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Intelligence. I' detectors offer a number of intelligent fea -res guilt-in remote ina,intenance signaling to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the P line to minimize Drift compensat~o? and smoo'hing algorithms nuisance alarms. Two-wire i3 detectors needing clean~ng can Simplified sensitivity measurement generate a remote maintenance signal, when connected to the Wide angle, duai color LED indication 2W-MOD2 loop test/maintenance -nodule, or to a panel equipped with the i3 protocol. This signal is indicated by LEDs located at,he oop testing via EZ Walk feature module and the panel. The SENS-RDR, a wireless device, displays the Built-in test switch sensltivityof i1 detectors in terms of percent per-foot-obscuration. Instant inspection. The i= series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on two-wire i3 detectors This feature verifies the initl3ting loop wiring by providing LED status indication at each detector. Agency Listings FM MEA MSFM APPLICATION O FIRE DETECTION SYSTEM LISTED .000 approved approved O FIRE PROTECTION SYSTEM 0 DISAPPROVED 0 APPROVED AS NOTED 0 APPROVED (U Smoke Detector Specifications Smoke detector shall be a System Se nsoi i3 Series model number__ listed to Underwriters Laboratories l1L 268 for Fire Protection Signaling Systems ihe detector shall be a phoioele,,lrc type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2Wl B, 4W'I~-B) with thermal sensor rated at 135°F (572°C).The detector shall include a mounting base for mounting to3'h-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaste, ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall alloy pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the J_ smoFe box, The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual colorLEl) indication which blinks to indicate power up, normal standby, outofsensitivlty, alarm, and freeze trouble (Model 2W I B 4WT Q'i co nol[lons. When used Ir conjunction vvltn the 2W-MC- module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel. and shall provide a loop bllity to verify the circuit without testing each detector individually. Cr1~ {ng A. ~le- 1_-)inal: 12/24V non-polarized M,r imum, 8.5V Maximum: 35V vlaxirnurnRipple',dt.:,30% peak to peak of applied voltage Standby Ci rent 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average xi1,1jIn Alt,ru 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12V, 23mA @ 24`.t 2-wire: 100 AA,4-wlre.n/a r, C0.1)(d t 2-wire n/a; 4-wire: 0.5 A @ 30V AC/DC _ f, - - t~imerslnns ;incl 5.3 Inches (127 mm) diameter; 2.0 inches (51 mm) height ydefg„t 6.3 oz, (178 grams) lperatir€yTernp 2W-B and 4W-B: 32°F-120°F (0°C-49°C; 2WT B and 4W f B:32°F-100°F (0"C-37 8'C) ire;atmu Fiunnidt- 0 to 95% RH non-condensing 13SF (57 2°C) fixed 7;, Ib;" 2WT-B and 4WT-B only. 417 (5°C - oy 2.5°/Utt. nominal si 14 22 AWG nch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling D 'uS rte Fte~d i_80 Condition t 'Ion Power up Blink. every 10 seconds Blink every 10 seconds lnltlal LED status indication 80 seconds Normal (standby) Blink every 5 seconds cff Out of sensitivity ofi Blink every 5 seconds Freeze trouble oft Blink every 10 seconds Alarm otf Solid Ordering Information 2W-B 2-wire 130 mA max. limited by control panel 2WT B 2 wire 130 mA max. limited by control panel s 4W B No 4-wire 20 mA @ 12V, 23mA C~ 24V 4WT-B Yes 4-wire 20 mA @ 12V, 23mA C 24V ....cc.~:rris5 2W-M~0D2 2-wire loop test/ maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket 6.6 in. (16.76cm) diameter 38,15 Ohio Avenue • St Charles, IL 60174 i Phone: 800-SENSOR2 • Fax: 630-377-6495 System Sensor ?.-wire Compatibility for SK-5208 by Silent Knight Pacye 1 of 1 2-wire Compatibility for TE Manufacturer: Silent Knight Model: SK-5208 ocJ.<:nixrii:.70ns ndvr nce-7 solutions' Detector Max Zone Base Model Detectors Zone Model [B,D e EOL ID Model B110LP, 7628 / 24J 1151 B401 16 5208, 5217 N/A 7628/ 2100.AT N/A 20 5208,5217 N/A 243 7628/ 21005 N/A 20 5208,5217 B, D N/A 24J 7628/ 24J 2100TR N/A 1 5208, 5217 B, D N/A 2100TS N/A 20 5208, 5217 B, D NAB / 243 B110LP, 7628/ 241 21.5 L B401 16 5208, 5217 B, D N/A BIIOLP, 7628/ 243 2151T 16 5208, 5217 B, D N/A 4 01 2W tjB 762 N/A 20 5208, 5217 B, D* N/A8 / 243 7628 / 2WT B N/A 20 5208, 5217 B, D* N/A 24J SK-5217, FC- B D* 7628/ 24J 2WTA-B N/A 20 5217 N/A SK-5217, FC- B D* 7628 / 241 2WT R-B N/A 1 5217 N/A 4451HT B401B 20 5208 B/D 4.7K 243 5451 B401B 20 5208 B/D 4.7K 241 * CAUTION: Fire alarm control panels vary by manufacturer on the implementation of style D (also called Class A) circuits. Therefore, the only way to insure the proper operation of 2-wire i3 smoke detectors on a Style D initiating device circuit (IDC) is to use a System Sensor 2W-MOD2 module. Any 2-wire i3 smoke detector (2W-B, 2WT-B, 2WTA- B, or 2W-FR-B) wired in the Style D initiating device circuit (IDC) configuration requires the use of a System Sensor 2W-MOD2 module. mhtrnl:tile://C:ADoctlnJentS and Settings\Brian Vandal\My Documents\Titan Power Solution... 1//3/2008 TIEPA EMWR Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert'°Advance selectable-output horns, strobes, o~ and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTMJ=,0 t The SpectrAlert Advance series of notification appliances is Features designed to simplify installations, with features such as plug in . Electrically compatible with existing SpectrAlert products designs, instant feedback messages to ensure correct installation of Automatic selection of 12- or 24-volt operation at 15 and 15/75 rndividial devices, and 1 1 eld-selectable candela set i-gs for wall candela and ceiling strobes and horn/strobes. Plug-in design When installing Advance products, firs- attach a universal mounting Field selectable candela settings on wall and ceiling units: 15, 15/75, plate to a four-inch square, four-inch octagon or double-gang 30, 75, 95, 110, 115, 135, 150, 177, 185 junction box. The two wire mounting plate attaches to a single-gang . Same mounting plate for wall- and ceiling-mount units junction box. Shorting spring on mounting plate for continuity check before Next, connect the notification appliance circuit wiring to the SEMS installation terminals on the mounting plate. -Tamper resistant construction • Outdoor wall and ceiling products rated from -40°F to 151 `F Finally, attach the horn, strobe or horn/srrobe to the mounting plate . Design allows minimal intrusion into the back box by inserting the product's tabs in the mounting plate's grooves.The . Horn rated at 88+ dbA at 16 volts device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place Rotary switch for horn tone and three volume selections with a catch until it is secured with a captured mounting screw. Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements The SpectrAlert Advance series includes outdoor notincation . Outdoor products rainproof per UL 50 (NEMA 3R) appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for Compatible with MDL sync module wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Agency Listings SIGNALING u~ F nn MEA approved LISTED APPROVED »sy, SpectrAlert Advance Specifications d mom ;~eral SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x I V2-inch back box, 4-inch octagon back I ~i )uble-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 1iA-Inch back box. A universal mounting plate shall be used for mounting ceiling and wall prodru ~le note _,tun apple ii,cF r !,t ui s?ring small terminate at the tcriversal mounting plate. Also, SpectrAlert Advantc products, vvhen ed with the Sync-( rcuit' Muc t Itl~ av.r,w y,'l gall I?r_ poweiea horn a n'11-Lodec nou(icauor appliance circuit output and shall operate uu ; nor r al I1 of volts. When ~s'd w rn the Syn Cie l: t ~VIOJuk, 12-volt rased notification appliance circuit outputs shall operate between "ern aru 175 volts; 24 volt r,ted eotificatlon appliance circuit Outputs Shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated D or =Jlkvavr, ie-ti' ed, unfiltered power ;upcly_ Strobes and horn/strobes shall have field-selccable candela settings including 15, 15//5, 30, 75, 95, 110, 1 15, 135, 150, 177, 185. ;trace The strnhe shall h tivstnm Hoar Slrer-ItAlert Advance Model listed to ,Jl 97' and shall be approved for fire prote(live i v;re Tl snnnr shall br, w:r_d as a orimary s g"allr I n -nfi,ation appllari( e and comply with the Americans with Disabilities Ac, requirements for v Bible sq, air g appli j ores, fla,hing at 1 Hz ovar the strok rrs enter(, o Ling voltage ear (1e The str:be light ;-all consist of a xenon flas', tube and assodated lens/rrf;ectw syslp'n I he hornhtrobr, snall hP "Hi ntiOr 1)i), ,i,,, Advan(c Model listed to UL 1971 and UL 4[4 and shall be rpprovcc foe fire pmtr,ctive scrvia The horn/strobe shall be wr, I a primary-signaling ncCir-ation applia-co and comply with the Americans with D'sabilitlcs Act require rner,t . for visible signaling applianc-s flash n at I riz over the strobe's entire operating voltage range the strobe light shall consist of r xenon flash t ; e and asset ia--leo lens/reflector system_Tha -~orr shall have three auc!bility options and an option to switch between a temporal t ree-cattern and a non-temporal (con^nuous) pattern.These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply. SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fah,enheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. ~~hur r~°t~oi The wodulr_ shall be a ` Tern Sensor Sync•Qrcuii model MDL listed to UL 464 and shall be approved for fire protective service. The mocule shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 411,,e x 4111ie x 21/3-inch back box.The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control, The module shall n ;sera on a coded power supply. w' f n: i,~4rti . 32°F to 120°F (0°C to 49°C) ;`•er,E~r7f>cratri; -40'T to 15 1'F (-40'C to 6oC) 10 to 93916 non-condensing (indoor products) r;be Fiaslr' ,t1 flash per second Vcminakvolr,q„ Regulated 12DC/FWR or regulated 24DC/FWR n,rar ir:7 Jolt 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) put iermh~al 12 to 18 AWG h,rh) ~r,r<1.n urt 6.8"diareterx25'high(1i3rnnrdierneteix64 iiii. Valle n:°dfc 5.61x4,7IN x2.5'D(1~12mf,,,Lx119rnmWx(.,,lmmD) urnr;mer S. ~I x4.7Wx1.3D(142Irr- 1_x119IrlrTI VVxITIF nt uvoll-mo:inf;,, r' BS- 9BSLV5.9 Lx SOWx2.2"D(1'll ITI Lx1,18mmWx56mmD) eiii o nowit fr,r f3BSCW-21 11" diameter x 2.25-high (180 mm Gamete-x 57 mm high; ~',lli^n r: 57~.tNBB) S/Ix',.1'Wx2.OD(145mmLxi30mrnWxSlmmD) in q r ,rws~E .t _ ,:.r r rrs t~'A V'SECj 7.1"diameter x 2.0'h'gh (180 mm diameter x 51 rnm high) 1. F ,l~ FN,we Recnh d 0 VP) ohage Is a non -regulated, time varylr g power source that is used on some power supply and panel outputs_ 2. P, S, PC, and SC products will overate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data e Ai: 16 t Volts V 33 Volt, FUt DI, FU,'R Sound Pattern cIF, f,,C: r 1,11 ` WR `;I'w;lard is, 123 128 66 71 Temporal High 57 51, 69 75 .n,d-L' n,+rrge 15/75' 142 148 77 81 Temporal Medium 44 49 58 59 30' NA NA 94 96 Temporal Lovv 38 44 44 48 77, NA NA 158 153 Non-temporal High 57 56 69 75 95' NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 gh 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA. NA 246 220 Coded Low 40 46 52 50 77 NA 281 251 185 Nn 286 258 ;'Volts 5'I S temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 lemporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 2C1 210 i-t',iS Itl>ut lemporal High 136 155 88 97 112 168 90 210 218 Temporal Medium 152 78 88 103 160 184 202 206 lemporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High i42 161 103 112 1,16 181 203 221 229 Non-temporal Medium 1 55 85 95 110 166 189 208 216 Non-tempor Low 154 80 90 105 161 184 202 211 "1r,t 8Svs; t,ipui Temporal High 245 259 290 297 Temporal High 2-15 231 258 265 lemporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 emporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medl,,m 2t259 293 299 Non-temporal Medium 219 232 262 267 Non temporal Low 138 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For Kseriesproduct us-I lu,,,tern-raWres,listed candela _ ratings must be reduced in acc Jance with this table. Po"ition `ound Pattern dF + - ";l 1 Temporal High 78 78 84 84 88 88 99 98 /75 e': 32°F 2 lemporal Medium 74 74 80 80 86 86 96 96 30 3 t'empor'al Low 71 73 76 76 83 80 94 89 75 44 4 Non temporal High 82 82 88 88 93 92 100 100 95 70 5 Non-temporal Medium 78 78 85 85 90 90 98 98 110 11C 6 Non-temporal Low 75 75 81 81 88 84 96 92 115 5 7+ Coded High 82 82 88 88 93 92 101 10, 135 135 St Coded Medium 78 78 85 85 90 90 97 98 150 '50 91 Coded Low 75 75 81 81 88 85 96 42 77 'Settings 7, 8, and 9 are ro available nr 2-v e porn/strobe. 85 SpectrAlert Advance Dimensions Dia. [-4.7- 6.a" Rii . rlirg-r*~~ 7.1" 2.25 1 Dla. 5.05-- x«2.23'1 D, a. *2~~ 2. 0" 0 00 0 5.ga- 5.r o ® o ° 0 0 Q O 0 0 Q 5.1"~ =k, , l I a ~x r f,.- k . Wall SpectrAlert Advance Ordering Information "M E , - Celling Hr rn/S;rol s [coTrt d_ P2R*" t tai d 1' PC2W- 2-wire Horn/Strobe, Standard cd, White P2RH' 2 wire Hoer/Strobe, Hiq'~ cd, Hen PC2WH`' 2 wire Horn/Strobe, High cd, White P2RK° 2-wire Horn/Strobe, Standard cd, Red, Outdoor PC4R 4-wire Horn/Strobe, Standard cd, Red P2RHK* 2-wire Horn/Strobe, High cd, Red, Outdoor PC4RH 4-wire Horn/Strobe, High cd, Red P2W* 2-wire Hom/Strobe, Standard cd, White PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor P2WH* 2-wire Horn/Strobe, High cd, White PC4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor P4R* 4 wire Horn/Strobe, Standard cd, Red PC4W 4-wire Horn/Strobe, Standard cd, White P4RH' 4-wire Horn/Strobe, High cd, Red PC4WH 4-wire Horn/Strobe, High cd, White P4RK 4-wire Horn/Strobe, Standard cc], Red, Outdoor Ceiling Strohes P4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor SCR* Strobe, Standard cd, Red P4W* 4-wire Horn/Strobe, Standard cc], White SCRH* Strobe, High cd. Red P4WI-* 4 wire Horn/Strobe, High cd, White SCRK Strobe, Standard cd, Red, Outdoor vJall Stroh s SCRHK Strobe, High cd, Red, Outdoor SR*` Strobe, Standard cd, Red SCW*' Strobe, Standard cd, White SRH*r Strobe, High cd, Red SCWH- Strobe, High cd, White SRK Strobe, Standard cd, Red, Outdoor Horns SRHK Strobe, Nigh cd, Red, Outdoor HR Horn, Red SW* Strobe Standard cd, White HRK Horn, Red, Outdoor SWH* Strobe, High cd. White HW Horn, White PC2R* 2-wire Horn/Strobe, Standard cc], Red BBS-2 Back Box Skirt, Wall, Red PC2RH* 2-wire Horn/Strobe, High cd, Red BBSW-2 Back Box Skirt, Wall, White PC2RK 2-wire Horn/Strobe, Standard cd, Red, Outdoor BBSC-2 Back Box Skirt, Ceiling, Red PC2RHK 2-wore Horn/Strobe, High cd, Red, Outdoor BBSCW-2 Back Box Skirt, Ceiling, White o t,!v Add'-P"to model number for piair housing (noT.RE"marking on cover), e.g., P2R-P t Add'-SP"to model numberfo! FUEGO"marking on cover, e.g., P2R-SP h"Standard cd;'refers to strobes that include 15, 15/75,30,715, 95, 1 10, and 115 candela settings. "High cd,'refers to strobes that include 150, 177, anc 185 candela settings. All outdoor units endir- in"K"Include a weatherproof back box, 3825 Ohio Avenue • St Charles, IL 60174 -50 y Phone 800-SENSOR2•Fax: 630-377-6495 ~ Farenhyt Conventional Pull Station Models PS-SA and PS-DA The PS-DA and PS-SA Pull Stations are manual pull stations which provide a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal. The PS-DA is a dual-action model. The PS-SA z = UL is a single-action model. Both the PS-DA and the PS-SA are yv equipped with key lock / reset. Both are designed to meet multiple applications with the installer and end-user in mind. Its innovative design, durable construction, and multiple mounting options make the PS-DA and PS-SA simple to install, maintain, and operate. The single-action pull-station is activated by a single pull-down of the alarm handle. The dual-action versions require pushing in the handle, then pulling the handle down for activation. The PS-DA and PS-SA manual pull stations are UL listed and meet the ADA requirement of a 5-lbs. maximum pull force to activate. Operating instructions are molded into the handle along with Braille text. Molded terminal numbers can be found adjacent to the wiring x'`h terminals. Models: PS-SA- Single action with 'pigtail' connections and a key lock reset. Pigtail wires are provided for connection to the Fire Alarm Control y Panel's (FACP) initiation circuit. PS-DA - Dual action model with screw terminal connections and a key lock reset. PS-DASP - Same as PS-DA except with both English and Spanish operating instructions. Features: nM • UL Listed Specification: • CSFM Listed Dimensions: • Meets ADA requirements Height: 5-1/2" (13.97 cm) • Operating instructions are molded into the handle along with Width: 4" (10.16 cm) Braille text. Depth: 1-7116" (3.65 cm) • Made of durable Lexan Operating • Available in Spanish temperature: 32°F to 120°F (0°C to 49°C) • Key resettable Electrical: • Easy to Install and operate Switch Contact • Single or dual action Rating: 0.25 A @ 30 VAC or VDC • Surface mount box available Accessories: SB-I/0 Surface Mount Back-box BG-TR Trim Ring 7550 SILENT Maple Meridian Circle Maple Grove, Mn 55369-4927 P/N 350250 Rev B, 10/06 KNIGHT 763-493-6455 Copyright @ 2006 Silent Knight 1-800-328-0103 [30 Fax: 763-493-7475 http://www.farenhyt.com ease III14 :t S Y I PS-DA PS-SA Rear PS-DA Rear 5 I "F --'4+ 90' Tt i "to PS-DA PS-DASP PS-SA SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications KN 1 G HT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. Made in the U.S.A. by HofsE?.Y'1e F:'i FIRE A' CONTROL PANEL Model 5208 Fire Alarm Control Panel with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. law The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features Built-in synchronization for • 10 zones, 8 Class B (Style B) and 2 appliances from AMSECO@, Class A (Style D) or Class B (Style Gentex@, Faraday, System Sensor, B) zones, expandable to 30 zones and Wheelock@ - • Supervised zone expanders and 1/0 Programmable date settings for modules can be mounted remotely Daylight Saving Time from the main control panel Clock source setting options for 50 • Event History Buffer (150 events) Hz, 60 Hz, or internal (uses the with date/time stamp panel's internal clock) • All zones are compatible with 2- or Specifications 4-wire detectors Operating Voltage: 24 VDC • 8 selectable/programmable output patterns for notification appliance Primary AC: 120 Vrms @ 60Hz, 2A circuits Total DC Load: 6 Amp • Built-in Digital Alarm Communicator Current Draw: Transmitter (DACT) Standby: 140 mA • 4 Notification Appliance Circuits Alarm: 460 mA • 4 programmable general purpose Flush Mounting Dimensions: relays Height: 24.75" (62.9 cm) • Programmable smoke verification, Width: 14.5" (36.8 cm) pre-alarm delay, cross zoning and Depth: 3-7/16" (8.73 cm) enhanced verification mode features with 5/8" protruding SK-5208 that can help minimize false alarms Overall Dimensions: • Programmable from the built-in Height: 26-3/8" (67 cm) SKSS Downloading Software control panel touchpad, remote Width: 17-3/16" (43.66 cm) Total Depth: 4" (10.16 cm) Plex-2 Door Option annunciator, or Windows@ SKSS downloading software Operating Temp: 32° to 120° F Listings and Approvals • Direct connect port for on-site (0° to 49° C) UL Listed up/downloading with Windows@ Humidity: 10 - 93% noncondensing CSFM Listed SKSS downloading software MEA approval 429-92-E Vol. XIII • Built-in walk test feature Optional Accessories • Single or dual interlock water SK-5235 LCD Remote Annunciator releasing capability SK-5217 10 Zone Expander • Plex door option combines a dead (2 max. per system) front cabinet door with a clear SK-5280 Status Display Module (8 window, limiting access to the panel max. per system) SILENT while providing single button 7181 Fire Zone Converter KNIGHT operation of the reset and silence 5220 Direct Connect Module functions 5824 Serial/Parallel Printer Interface • Programmable AC trouble relay Module by Honeywell FIRE A' CONTROL PANEL Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 Direct Connect For On-Site Programming 2 Class A (Style D) _ or Class B (Style B) Initiation Circuits Programmable Form C Relays 8 Class B (Style B) Notification Initiation Circuits Wr`: Appliance Circuits 5235 Remote Annunciators SBUS Devices - 5280, 5217, & 5824 To AC SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350318 Rev B, 11/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Copyright © 2005 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. #kiEiaE Arujeet baflses Narrt~ Tutor Time Learning Center Sl t~dTby ~3.w 24 1?. TD. Atar+11 N..ns: 15 ~I . #reparsd #3y B Vandal Titan Power Solutions €)erattng 1 aea 1.2 • • €3at$ 11 /14/2007 wattage #3xs3p infarnmg #rreshoEs! 10 ~ -,ul•tAnt O-Amps Panel IQ. SK-5208 tfk E K 5 E?$: ire Alarm Control Panel Max.RACX Location. Emerald P!Ty Dublin, OH fol 4 I]G ' Max ftM` ZUrr~nt a-b Ampa Cur~erttlraw #ilttlt A#E%f ohms per xixitx9ft1{ ' Atal Wig Ckt.# trCF.. City St*Md ATarrn _ low Ft. .Of 1- ~ttl"t& <i•A€Ib. SEA 5208 SK-5208 Main Control # 0.140 0.160 NAC 0-KT SK-5208 Prgmd NAC's 2 0.000 0.080 ALi1A RL`f.; SK-5208 Pam Alm RI 0.000 0.000 E~,529: SK-5217 Zone Ex dr 0-000 0 000 E452i SK-5235 LCD Remote 0.000 0.000 SK~528C.;:, SK-5280 Display Mod 0.000 0.000 SK:.223': SK-5220 Dir Con Mod 0.000 0.000 SK 7113;::: SK-7181 Zn Cnvtr 0.000 0.000 IDG1 Initiating Device Ckt 1 0 001 0.095 IDC 2 Initiating Device Ckt 2 0.001 0 .095 IDG-3, Initiating Device Ckt 3 0.001 0.095 IOC-4 Initiatin Device Ckt 4 0.000 0 000 [Dr,-5 Initiating Device Ckt 5 0,000 0 000 IDC-6` Initiating Device Ckt 6 0.000 0.000 IDC-7 Initiating Device Ckt 7 0.000 0.000 IDC-8 Initiatin Device Ckt 8 0.000 0 000 IDC-9 ! Initiating Device Ckt 9 0.000 0.000 JO 10 Initiating Device Ckt 10 0.000 0.000 fF. DC-11 Inactive,: Xjdd:SK;-52 I 1.7 0.000 0.000 ~ InG 12 ktaGtivs,: Add:3K52170.000 0.000 A iDC-13 - kt6ctive,:Addt6C5217:: 0,000 0.000 IDC 14 ! 6a ti~e,: ,odd 8K 52i7 : &000 a GOO IOC-15 Inact:Vq',: Aq'd SfG52'1.7 0.000 0.000 IDC-16` Iriadtive, Add:SK521.7•.0.000 0.000 IDG-17 biaotide,: Add:SK=521.7. 0.000 0.000 IDG 18 triactlye,: ndgl:SK-5217: &000 0.000 { IDC-19> VZ c'tlve,: ;4dd:SK,-521•,7. 0.000 0.000 IDC-20 klaCtivd,: A,dd:8K5217 0.000 0.000 IDC-21 ktactive,: Add:SK5217 : 0.000 0.000 JDC-22 ktactivt Kidd SK 5217: 0.000 0 000 IDC-23 ku3ctju~,: A6d:SIG$21.7•.:: 0.000 0.000 IDC 24 Iriadtive,: Add:SK5217 0.000 0.000 IOC-25 triaotiJe,: Add:8 K521.7 0.000 0.000 JDt 26 triactlve,' Add:SK-5217 0.000 0.000 IDC-27 .4-Ogtive,:4dd:$E(521•,7.:: 0.000 0.000 IDC,28' f+laGtive,: A, dd:8K 5217 0.000 0.000 f IDC-29 fricative,: ,odd $ K 5217: 0.000 0.000 f IDC 30 Irtacti*:,oddSK 5217: 0.000 0.000 NAC-1 Notification Appr Ckt 1 0.000 1.392 #18 Solid 6 39 425 5,43 12,84 a7;W° NAC-2: Notification Appl Ckt 2 0.000 1.305 #18 Solid f.39 425 5.43 13 31 4AG 3 ltiaotlJe, Aiid ~FAC: O KT : 0.000 0,000 #12 Solid 1.59 0.00 20,40 0.00% NAC-4 triactlve,:Adii t4AC: bKT:: 0.000 0.000 #12 Solid 50 fl i0 204a 0.00% Aril Aux Power Out 0.000 0.000 #12 Solid 3 59 _ t:f)E3 2Ll;4t3 0.00% 1 ataE Stanc€ Ci irrent :t 0.142 3.222 Tcta1 Atariti.f,.' rrirnt Am 5taodty T#ne I 1 Hours 24 0.250 AiarmTim In [sal Omt. .60 {35 MEOW} . . 1'atsE aiie3 AN .R cared 3.4Q3 0.806 atal A-brraAN t t. uired` pt-a GUft bU-*dAH R.Oured 4;21 Command Shortcuts H ThDerafi 'actor ? 20 Mitllt# VM- Utt AMrfHbttr$ Regw.w R Configure Circuits 1 Print Page •f Circuit Configuration Project Information Project Name: Tutor Time Learning Center Project ID: 0 ' Prepared By: B Vandal Titan Power Solutions Date: 11/14/2007 Ckt. Number: IDC-1 Panel ID: SK-5208 Ckt. Name: Initiating Device Ckt 1 Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 12 System Sensor 2100 0.000 0.100 0.001 1.200 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.001 0.095 Ckt. Number: IDC-2 Panel ID: SK-5208 Ckt. Name: Initiating Device Ckt 2 Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 12 System Sensor 2100 0.000 0.100 0.001 1.200 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.001 0.095 Ckt. Number: IDC-3 Panel ID: SK-5208 Ckt. Name: Initiating Device Ckt 3 Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 12 System Sensor 2100 0.000 0.100 0.001 1.200 Unused 0.000 0.000 0.000 0.000 Unused OMO 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.001 0.09541 sr Configuration Project Information Project Name: Tutor Time Learning Center Project ID: 0 Prepared By: B Vandal Titan Power Solutions Date: 11/14/2007 Ckt. Number: NAC-1 Panel ID: SK-5208 Ckt. Name: Notification Appl Ckt 1 Max NAC Current: 3.0 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 16 Gentex HS24-15/75 Horn/Strobe 0.000 0.087 0.000 1.392 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0000 0.000 0.000 0.000 Totals 0.000 1.392 Ckt. Number: NAC-2 Panel ID: SK-5208 Ckt. Name: Notification Appl Ckt 2 Max NAC Current: 3.0 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 15 Gentex HS24-15/75 Horn/Strobe 0.000 0.087 0.000 1.305 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 11 1.305 Ckt. Number: NAC-3 Panel ID: SK-5208 Ckt. Name: Inactive, Add NAC-CKT Max NAC Current: 3.0 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 FIRE ALARM CONTROL PANEL Model 520r Fire Alarm Control Panel with Digital Commun cator r The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. Y The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features Built-in synchronization for • 10 zones, 8 Class B (Style B) and 2 appliances from AMSECOO, Class A (Style D) or Class B (Style Gentexc", Faraday, System Sensore, B) zones, expandable to 30 zones and Wheelock( • Supervised zone expanders and 1/0 Programmable date settings for modules can be mounted remotely Daylight Saving Time from the main control panel Clock source setting options for 50 • Evert History Buffer (150 events) Hz, 60 Hz, or internal (uses the with date/time stamp panel's internal clock) • All zones are compatible with 2- or Specifications 4-wire detectors • 8 selectable/programmable output Operating Voltage: 24 VDC patterns for notification appliance Primary AC: 120 Vrms @ 60Hz, 2A circuits Total DC Load: 6 Amp Built-in Digital Alarm-Communicator Current Draw: Transmitter (DACT) Standby: 140 mA • 4 Notification Appliance Circuits Alarm: 460 mA • 4 programmable general purpose Flush Mounting Dimensions: relays Height: 2475" (62.9 cm) • Programmable smoke verification, Width: 14.5" (36.8 cm) pre-alarm delay, cross zoning and Depth: 3-7/16" (8.73 cm) enhanced verification mode features with 5/8" protruding SK-5208 that can help minimize false alarms Overall Dimensions: • Programmable from the built-in Height: 26-3/8" (67 cm) control panel touchpad, remote Width: 17-3/16" (43.66 cm) SKSS Downloading Software annunciator, or Windows"~ SKSS Total Depth: 4" (10.16 cm) Plex-2 Door Option downloading software Operating Temp: 32° to 120° F Listings and Approvals • Direct connect port for on-site (0° to 49° C) UL Listed up/downloading with Windows'D Humidity: 10 - 93% noncondensing CSFM Listed SKSS downloading software MEA approval 429-92-E Vol. XIII • Built-in walk test feature Optional Accessories • Single or dual interlock water • SK-5235 LCD Remote Annunciator releasing capability SK-5217 10 Zone Expander • Plex door option combines a dead (2 max. per system) front cabinet door-with a clear SK-5280 Status Display Module (8 window, limiting access to the panel max. per system) SILENT while providing single button 7181 Fire Zone Converter KNIGHT operation of the reset and silence 5220 Direct Connect Module functions 5824 Serial/Parallel Printer Interface • Programmable AC trouble relay Module by Honeywell FIRE ALARM CONTROL PANEL Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Lire 1 Telephone Line 2 Direct Connect For On-Site Programming - - Class A (Std car Class B (t, le B) Initiation Ci~ ..>a, n . Programmable Form C Relays Class B (Style S) 0" N~tl cation Initiation Circuits A-~p~t_.~1G~, Circuits demote Annunciator 5E U'-'o Devices 5280, 5217, & 5824 To AC ILVNT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350318 Rev B, 11105 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Copyright © 2005 Silent Knight Phone: (800) 328-0103. Fax: (763) 493-6475. FIRE ALARM CONTROL PANEL Model 5208 7 b Fire Alarm Control Panel with t a Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. } The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features Built-in synchronization for • 10 zones, 8 Class B (Style B) and 2 appliances from AMSECOCI) Class A (Style D) or Class B (Style Gentex~', Faraday, System Sensor RD, B) zones, expandable to 30 zones and WheelockO • Supervised zone expanders and 1/0 Programmable date settings for modules can be mounted remotely Daylight Saving Time from the main control panel Clock source setting options for 50 • Event History Buffer (150 events) Hz, 60 Hz, or internal (uses the with date/time stamp panel's internal clock) • All zones are compatible with 2- or Specifications 4-wire detectors • 8 selectable/programmable output Operating Voltage: 24 VDC patterns for notification appliance Primary AC: 120 Vrms @ 60Hz, 2A circuits Total DC Load: 6 Amp • Built-in Digital Alarm Communicator Current Draw: Transmitter (DACT) Standby: 140 mA • 4 Notification Appliance Circuits Alarm: 460 mA • 4 programmable general purpose Flush Mounting Dimensions: relays Height: 24.75" (62.9 cm) • Programmable smoke verification, Width: 14.5" (36.8 cm) pre-alarm delay, cross zoning and Depth: 3-7/16" (8.73 cm) enhanced verification mode features with 5/8" protruding SK-5208 that can help minimize false alarms Overall Dimensions: SKSS Downloading Software • Programmable from the built-in Height: 26-3/8" (67 cm) control panel touchpad, remote Width: 17-3/16" (43.66 cm) annunciator, or Windows`` SKSS Total Depth: 4" (10.16 cm) Plex-2 Door Option downloading software Operating Temp: 32° to 120" F Listings and Approvals • Direct connect port for on-site (0° to 49° C) UL Listed up/downloading with Windows© Humidity: 10 - 93% noncondensing CSFM Listed SKSS downloading software MEA approval 429-92-E Vol. XIII • Built-in walk test feature Optional Accessories • Single or dual interlock water • SK-5235 LCD Remote Annunciator releasing capability SK-5217 10 Zone Expander • Plex door option combines a dead (2 max, per system) front cabinet door with a clear SK-5280 Status Display Module (8 window, limiting access to the panel max. per system) SILENT while providing single button 7181 Fire Zone Converter KNIGHT operation of the reset and silence 5220 Direct Connect Module functions - - • 5824 Serial/Parallel Printer Interface • Programmable AC trouble relay Module by Honeywell FIRE A' CONTROL PANEL Model 5208 y,. Ily Fire Alarm Control Panel with Digital Communicator --Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telepmin Line 1 Telephone Line 2 Direct Connect For On-Site Programming 2 Class A (Slyk--, D) or Class B :yle B) Initiation Circuits Programmable Form C Relays 3 Glass B (Style B) - Notification Initiation Circuits IV, Appliance Circuits _ 5235 Remote Annunciators ? SBUS Devices 5280, 5217, & 5824 To AC SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA NIGH keep our product information up-to-date and accurate. We cannot cover all C N3 specific applications or anticipate all requirements. All specifications are FORM# 350318 Rev B, 11/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Copyright © 2005 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475.