Loading...
07200449 Permit File i CITY OF DUBLIN ;io~ipp uilding Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 one: (614) 410-4670 • Inspection Line: (614) 410-4680 v 2 O;u 1, WTFD: (614) 889-2347 fvi~{u 5 FIRE PROTECTION PERMIT APPLICATION e Application Date Bldg. App. # Fire Protection App. # ~ T Zoo Lky PROJECT INFORMATION Project Address 4 ~ ~ W ~1s~l Gah Uc ~ L ~.i'~. Project Name Ki \;(f I~IC (-ic - bcL e) Owner/Tenant Contact Name Telephone APPLICANT INFORMATI Fire Protection Contractor ' tit c .k.~CC C. Address , r . Ry"11,41 'Pd, .t--I< ~N t 1 `Telephone 01 LA L L- 70 State Certificate N}! er g 95 1117 Dublin Registration Number D 1- IA5 Installer Name V-0c State Certificate Number :3H 61S SCOPE OF WORK (Mark One) New Replace Repair Alteration FIRE DETECTION AND ALARM SYSTEM (Number of Each) pv_kI state . Detectors Strobes Horns aC ArV Fire Alarm Boxes Q, Othep K SUPPRESSION SYSTEM (Number of Each) Standpipes On Site Water Piping Sprinkler Heads Limited Area Other FEES X' CO FIRE DETECTION OR SUPPRESSION PERMIT PROCESSING FEE $50.09' LOW VOLTAGE PERMIT (DETECTION ONLY) $30.00 Minimum fee plus $20.00 each 1,000 sq ft or fraction thereof over 1,000 sq ft OUTSIDE PLAN REVIEW SERVICES (EXAMINER'S FEE AS CHARGED) l~30' DD STATE SURCHARGE (3%) ' 3 TOTAL FEE DUE ?1 ~P- 3 c7 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. This permit conveys no right to open any street, alley or sidewalk or any part thereof, nor to make any connection to a water main. Signature of Licensed Contractor r DATE FOR OFFICIAL USE ONLY • /~~f Review Comments: X A& 1;-e pzVAwhme v/i • s Sle d1z?w1a4w WOSAI;7if To fie De en w/• x o~1~ L/ dor Fire Department: 05 ;e' Nr Date: 3 s~8 0 ,hyl Plans Examiner: bjkc-Date: Issued by CBO: Date: 1AVE-) River Ridge Building B - Fire Alarm/Detection System March 27, 2007 07-200449 Page 2 3. Fire Alarm System cable and wiring located in noncombustible plenums shall meet with the requirements of Section 907 OBC and Article 760, NFPA 70. 4. Provide a record of completion for each completed fire alarm system in accordance with Section 907.17 and NFPA 72 Completion Documents. 5. Upon completion of the fire protective signaling system, all alarm-initiating devices and circuits, alarm- indicating appliances and circuits, supervisory-signal initiating devices and circuits, signaling line circuits, and primary and secondary power supplies shall be subjected to a 100 percent acceptance test in accordance with NFPA 72A and 72E listed in Chapter 35; Section 907.16 OBC. 6. OBC 907 Acceptance testing: When the installation of the detectors is complete, each detector and all interconnecting wiring for multiple-station detectors shall be subject to a 100-percent acceptance test in accordance with the household fire warning equipment provisions of NFPA 72 listed in Chapter 35. 7. No electrical work (conduits, cables or other electrical apparatus) may be covered or concealed without visual inspection and approval by the electrical field inspector as per OBC 109. 8. All electrical work will comply with the requirements of Article 27 OBC and the National Electric Code NFPA 70, OBC approved edition and is subject to the approval of the electrical inspector, in accordance with Section 109 of the OBC. TO REQUEST AN APPEAL HEARING, YOU MUST send a written request, listing the items to be appealed and the relief sought and on copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin, Ohio 5800 Shier Rings Road Dublin, Ohio 43017-1236 THIS RECORD OF OUR REVIEW OF DOCUMENTS IS TO BE SIGNED BY THE OWNER OR HIS/HER AUTHORIZED AGENT AND RETURNED, ALONG WITH ANY REQUESTED INFORMATION, TO THIS BUILDING DEPARTMENT BEFORE BEGINNING WORK, BUT NOT MORE THAN 30 DAYS AFTER ISSUANCE. FAILURE TO COMPLY MAY RESULT IN REVOCATION OF THE BUILDING PERMIT. THE SIGNING OF THIS DOCUMENT IS AN AGREEMENT THAT YOU WILL COMPLY WITH ALL ITEMS LISTED HEREIN. THE COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF ALL ITEMS LISTED HEREIN. Reviewed and signed, Michael A. Boryca, Architect/Plan Examiner e S yler, Chief Building Official (614) 488-4009 City o blin, Ohio City of Dublin FIRE PROTECTION PLAN REVIEW 07-200449 CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Applications #07-200449 March 27, 2007 PLAN APPROVAL FIRE ALARM/DETECTION SYSTEM THIS IS NOT A BUILDING PERMIT. IT IS A RECORD OF OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT. Re: River Ridge Building B Applicant: Roehrenbeck Electric, (614)443-9709 4345 West Dublin-Granville Road Dublin, Ohio Fire Protection Permit No: 07-200449 The Fire Alarm Documents dated , submitted with the Fire Protection Permit Application, for the captioned project, have been reviewed for compliance with the provisions of the 2005 Ohio Building Code (OBC). The review was based upon the following criteria: Use Group: R-2, Residential Dwelling Units Occupancy: No Change Area: No Chnage Const. Type: VB, Combustible Construction I Un-Protected Structure Notes: Installing a new fire alarm system for the new Shell Building spaces as proposed. The fire protective signaling system drawings have been Certified by Robert G. Sines III, Ohio certification no. F-032, the fire protection Contractor is Roehrenbeck Electric, Ohio certification #53-25-1117, the installer has been identified as Rocky Waybright, Certification #54-25-2355, all to comply with the requirements of OBC Section 105.3 and have been reviewed, therefore, in accord with OBC section 105.3.1.4. This PLAN APPROVAL for the fire protective signaling system only, is issued by the City of Dublin, Division of Building Standards, in accordance with Section 106.3.1 OBC. For the information of the Applicant the following item(s) are required for code compliance, but are not necessarily covered in detail in the construction documents. This list is a reminder to the design professional and contractors of issues which are to be satisfactorily dealt with in the field: 1. The certificate of approval of fire protection plans shall be posted in a conspicuous location outside of the building or in the front part of the premises on which is, or will be, located the approved building or equipment. The owner and the contractor shall, so far as possible, preserve and keep said certificate until the completion of the work to which the approved construction documents relate; Section 105.7.2 OBC. 2. The proposed construction shall conform to the requirements of Chapter I 1 OBC and the "Americans with Disabilities Act Accessibility Guidelines" (ADAAG). City of Dublin FIRE PROTECTION PLAN REVIEW 07-200449 CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00200449 Date 3/28/07 Property Address . . . . . . 4345 W DUBLIN-GRANVILLE RD Parcel Number: 273-008269 Alternate Address: SHOPPES AT RIVER RIDGE Tenant nbr, name . . . . . . RIVER RIDGE 'B' DETECTION Application type description FIRE PROTECTION Property owner . . . . . . . THE SHOPPES AT RIVER RIDGE Contractor . . . . . . . . . ROEHRENBECK ELECTRIC INC Permit . . . . . . FIRE DETECTION PERMIT Additional desc . . Permit Fee . . . . 60.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 60.00 Special Notes and Comments CONTACT WASHINGTON TOWNSHIP FIRE PREVENTION FOR INSPECTIONS AT 766-0857 Other Fees . . . . . . . . . OUTSIDE PLAN REVIEW 150.00 SURCHARGE FEE - BLDG 4.50 SURCHARGE FEE - FIRE 1.80 Fee summary Charged Paid Credited Due Permit Fee Total 60.00 .00 .00 60.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 156.30 .00 .00 156.30 Grand Total 216.30 .00 .00 216.30 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. River Ridge Building B - Fire Alarm/Detection System March 27, 2007 07-200449 Page 3 Signature - Architect, Engineer, Contractor Date or Owner Print Name and Title as Signed c: Washington Township Fire Department MAB:Iwb City of Dublin FIRE PROTECTION PLAN REVIEW 07-200449 Shoppes at River Ridge II Shops @ River Ridge B&C 6436 Riverside Drive Dublin, OH 43017- 925962003 / 583-402144-03 Specification Sections Electrical Contractor 16721(A) Fire Alarm System (Addressal Roehrenbeck Electric 2525 English Road Columbus, OH 43207-2840 Telephone: (614) 443-9709 FAX. (614) 443-9723 Electrical Engineer Branch Manager: Mike Skunza Prater Engineering Associates, Inc. Operations Manager Don Pullen 6130 Wilcox Road Project Engineer: Christopher Johnson Dublin, OH 43016- Ops Coordinators: Tom Pritchard Telephone (614) 766-4896 Sales Representative: Thomas Berry FAX: (614) 766-2354 26-Feb-07 SimplexGfinnell 6175 Shamrock Court Suite S Dublin, Ohio 43016-3250 MAR 0 5 2007 Sales: 614-602-2000 s Service: 614-602-2002 BULD !VISION FAX: 614-602-2011 ~T~ 011-- D 1-) ~ I O 4-o O O v Simplex6rinnell Scope of Work Shoppes at River Ridge 11- Building B & C Fire Alarm System This project involves the installation of new 4010 fire alarm systems at 6436 Riverside Drive. A new 4010 fire alarm panel (FAP) and peripheral devices will be installed throughout Buildings B & C of the facility. The project involves the following: 1. Installation of a 4010-9 fire alarm panel (FAP) per provided floor plans and riser diagram. Mount panel at U-0 ab ve finished floor. 2. Installation of manual pull stations per provided floor plans and riser diagram. 3. Installation of smoke detectors per provided floor plans and riser diagram. 4. Installation of monitor IAMs. These IAMB will be used to monitor sprinkler flow and tamper switches. 5. Installation of horn/strobe notification appliances per provided floor plans and riser diagram. Mount at 80-inches above finished floor or 12-inches below ceiling. A system general alarm will: 1. Indicate the general alar~yeondition and the device in alarm at the FAP and annunciators. The system alarm LED shall flash and an alarm tone will sound at the control unit until the alarm has been acknowledged. Once acknowledged, this same LED shall latch on. A subsequent alarm received from another device shall flash the system alarm LED on the control unit. The display shall show the new alarm information. 2. Operate the audible and visible alarm notification signals on the affected floor only. The audible devices shall sound until silenced, while the visual devices will flash until they are reset at the FAP or annunciators. Any subsequent alarm shall reactivate the alarm notification appliances. Other items: 1. All project wirin hall be installed in strict compliance with local codes and the provisions of NEC Article 76~ 2. The fire alarm system is to be tested in accordance with NFPA-72. The test is to be completed and witnessed by the owner's representative. Drawings and submittals were completed in accordance to drawings submitted by Prater Engineering. I /~w) A a~ a cr W IlSimplex TrueAlarm® Fire Alarm Controls UL, ULC Listed; FM, CSFM, Model 4010 Fire Alarm Control Panel for TrueAlarm and MEA (NYC) Approved* Analog Sensors and IDNetTm Addressable Devices IIIBiIIllilllilillllllllllililllllllllllllllllll~llllllhll ~ Standard features include: • Up to 250 addressable TrueAlarm sensor or addressable device points using IDNet communications that operate with either shielded or unshielded twisted pair wiring" • Four, 2 A notification appliance circuits (NACs) with solid state current protection • Internal event reporting DACT module (standard on models 4010-9101, 4010-9102, & 4010-9150) UL listed to Standard 864 Installation convenience features: • Power-limited design with electronic modules contained Illilllfliill111111(iilllllllllllllllNlllGj1I4111111111111 on one-piece chassis • Up-front terminal blocks for wiring access 4010 Fire Alarm Control Panel (with standard door) • Compact NEMA 1 rated cabinet is available in beige or red and can be pre-shipped for early installation - • • Setup, programming, and maintenance features: TrueAlarm fire alarm control panels have the ability • Device level ground fault search, locate and isolate to provide location accuracy for monitoring and control. • Auto Program for general alarm operation When equipped with TrueAlarm analog sensing for • TrueAlarm individual analog sensing with front panel smoke and heat detection, the processing power of the information and selection access control panel also has the ability to analyze conditions at • "Dirty" TrueAlarm sensor maintenance alerts, service each location to provide accurate detection with and status reports including "almost dirty" significantly reduced maintenance costs. • Default TrueAlarm sensor device type operation The 4010 TrueAlarm Fire Alarm Control Panel has been • Duplicate address error detection specifically designed to provide addressable operation and • Front panel or PC programming analog detection in a cost-effective package for • TrueAlarm sensor peak value performance report application sizes that previously were considered only • WALKTESTTM silent or audible system testt appropriate for conventional zoned monitoring. • Software verification simulation mode Installation and Service Ease. The 4010 mounts on a single chassis for quick installation and removal. Supports the following IDNet devices: Terminal blocks are large and up-front for easy access • Addressable manual stations and inspection. Optional modules are easily and quickly • Quad-state zone adapter modules (ZAMs) for initiating installed and programmed as required. device monitoring The 4010 cabinet provides convenient stud markers for • IDNet ground fault/short circuit isolator base for drywall thickness and nail-hole knockouts for quicker TrueAlarm sensors mounting. Smooth cabinet surfaces are provided for • Quad-state line powered individual addressable modules locally cutting conduit entrance holes exactly where (IAMB) for initiating device monitoring and relay control required. 4010 cabinets and electronics can be ordered Available option modules include: separately, allowing early cabinet installation. • Door mounted 24 LED annunciator (std. on ULC models) Ground Fault Assistance. Ground fault problems • Network, or Point Reporting DACT often occur during installation. The 4010 provides • Class A NAC adapter module isolating circuitry and software-controlled sequencing to isolate ground faults to specific identified locations. This • RS-232 ports for printer and maintenance PC assistance helps the installer to accurately locate the • Additional power supply; Auxiliary Relay Module or wiring problem for quicker repair. City Interface Refer to page 6 for listing details. This product has been approved by the California State • Equipment for Suppression Release Applications Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. (refer to data sheet S4010-0003) See CSFM Listing 7170-0026:226 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible Compatible with Simplex 8 auxiliary panels: cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the • TrueAlerto Addressable Controllers and NAC power latest status. Listings and approvals under Simplex Time Recorder Co. are the properly of extenders (IDNet controlled and conventional) Tyco Safety Products Westminster. TrueAlarm analog smoke detection and IDNet addressable devices are protected by one • 4003 Voice Control Panel or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5,400,014; • 4081 Battery Cabinet with charger for 50 Ah batteries 5,552,765; 5,552,763; DES. 377,460. t WALKTEST system test is protected under U.S. patent # 4,725,818. S4010-0001-9 10/2004 Extensive Feature List. The 4010 Fire Alarm Control Convenient Status Information. With the locking Panel provides access to an extensive feature list that door closed, a window allows viewing of the status includes: display. The 4010 status panel provides a two line by 40 character, super-twist LCD information display and eight • Providing easy and powerful operator information with a logical, menu-driven display status LED indicators as shown in the illustration below. • Extensive and automatic diagnostics for maintenance From this display, the LED indicators will describe the reduction general category of activity being displayed with the LCD • History Logs available from the LCD or capable of providing more detail. For the authorized user, unlocking (optionally) being printed the door will provide access to the control switches and allow further inquiry by scrolling the display for • Software Verification, allowing detailed logic additional detail. (Refer to control panel functional programming simulation to be conducted without illustration below.) activating corrected outputs Control Panel (or service PC) label editing WALKTEST Diagnostic Operation Mode. The • patented WALKTEST process allows a single person to Password access control perform system test. The system records test inputs such • Auto Program Quick Configuration (Quick-CFIG) of as intentional alarms or trouble and either logs the connected modules and IDNet devices for general alarm response (silent WALKTEST operation) or outputs a operation to quickly get the system up and running brief, recognizable audible notification signal (audible WALKTEST operation). FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information, LEDs flash to indicate the condition and then when acknowledged, remain on unfit reset THREE PROGRAMMABLE LEDs 2 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal provide custom labeling (labels insert into operafing conditions, provides up to 40 characters for custom label information a pocket), the top two LEDs are o (7 FIRST ALARM DISPLAY: Operation can be selected for maintained display of first selectable as red or yellow, the bottom alarm until acknowledged LED is selectable as green or yellow SYSTEM IS NORMAL USYSTEM SYSTEM CONTROL PANEL VIEW with SYSTEM RESET restores 4010 door dosed ; control panel to normal when OWNS -f all alarmed inputs are AC NEV TR~~BLE SYSTEM returned to normal OUT /M. 'TKAM CLEAR ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge and silences the operator NINE EXTENDED FUNCTION KEYS (accessible with panel and all annunciator tone-alerts door open) select and scroll through display prornits for locating additional system information, performing maintenance functions, or for front panel programming SUPV ACK acknowledges system supervisory conditions, logs the acknowledge, and silences the ALARM SILENCE causes audible notification appliances operator panel and all annunciator tone-alerts to be silenced, used after evacuation is complete and while alarm source is being investigated TROUBLE ACK acknowledges system troubles, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts 2 S4010-0001-9 10/2004 Overview. The 4010 provides IDNet addressable device TrueAlarm heat sensors can be selected for communications. Using a two wire circuit, individual rate-of-rise detection as either 15° F (8.3° C) or 20° F devices such as manual fire alarm stations, TrueAlarm (11.1 ° C) per minute with an independent fixed limit of sensors, and sprinkler waterflow switches can be directly 135° F (57° C) or 155° F (68° C). TrueAlarm heat sensors connected (or interfaced) to the IDNet controller to can also be programmed as a utility device to monitor for communicate their identity and status. This addressability temperature extremes in the range from 32° F to 155° F allows the location and condition of the connected device (0° C to 68° C). This feature can provide freeze warnings to be displayed on the 4010 panel LCD and on system or alert to HVAC system problems. annunciators. Additionally, control circuits (fans, To additional IDNet dampers, etc.) may be individually controlled by using a devices, up to 250 total relay IAM (individual addressable module). The 4009 IDNet NAC Extender or the TrucAlert Addressable - - controller can be controlled for local or remote ~E~~3i~ii• notification appliance expansion. (Refer to individual device documentation for further details.) Capacity. A total of 250 addressable monitor and controls Modular TrueAlarm points may be intermixed on the same pair of wires. By TrueAlert Addressable Controller sensor with base using Zone Adaptor Modules (ZAMs) or Individual Addressable Modules (IAMB), conventional initiating devices can be connected to the IDNet circuit. IDNet Addressable Operation. The IDNet controller continuously interrogates each addressable device on the Supervised IAM Modular TrueAlarm sensor communication channel for status condition such as: with IDNet isolator base normal, off-normal, alarm, supervisory, or trouble. ' -i 11 EIIIEIIIIIiIIIiI Sophisticated poll and response communication • techniques ensure supervision integrity and allow for "T-tapping" of the circuit for Class B (Style 4) operation. Addressable station ¦ Wiring Requirements. Refer to the specifications chart o 0 400Extte der below. Distances are for shielded or unshielded wire. Shielded wire may provide protection from unexpected o 0 sources of interference and may be required for some Quick-Connect Monitor ZAMs and applications. TrueAlarm sensor Relay IAMB Wiring Specifications Size 18 AWE minimum Preferred Shielded twisted pair (STP) 4010 Fire Alarm Wire Control Panel with Acceptable Unshielded twisted pair (UTP) annunciator door Farthest Distance from Control Up to 2500 feet (762 m) Panel to Device Total Wire Length Allowed With u uu tll~Igltlu~ltlaolmla®umtll~lKp Up to 10,000 ft (3 km). "T" Taps for Class B Wiring 4010 Control Panel with Typical IDNet Devices Diaanostics and Default Device Twe TrueAlarm System Operation. IDNet communications are used for TrueAlarm smoke and temperature sensors. TrueAlarm operation gives the 4010 system the ability to Every four seconds, smoke sensors transmit an output automatically indicate when a sensor is almost dirty, dirty, value based on their smoke chamber condition. The 4010 and excessively dirty. The NFPA 72 (National Fire Alarm CPU maintains a current value, peak value, and an average Code) requirement for a test of the sensitivity range of the value of each sensor's output. Status is determined by sensors is fulfilled by the TrueAlarm ability to maintain comparing the current sensor value to its average value. the sensitivity level of each sensor. Tracking this average value as a continuously shifting Modular TrueAlarm sensors use the same base and different reference point filters out environmental factors that cause sensor types (photoelectric smoke sensor, or heat sensor) shifts in sensitivity. can be easily interchanged to meet specific location Programmable Sensitivity. The sensitivity of each requirements. This feature also allows intentional sensor sensor can be field programmed at the 4010 Control Panel substitution during building construction. When conditions for different levels of smoke obscuration (in percent) or are temporarily dusty, instead of covering the smoke sensors for specific heat detection levels. In order to evaluate (causing them to be disabled), heat sensors may be installed whether the sensitivity should be revised, the peak value without reprogramming the control panel. Although the is stored in memory and can be easily read and compared control panel will indicate an incorrect sensor type, the heat to the alarm threshold directly in percent. sensor will operate at a default sensitivity to provide heat detection for building protection at that location. 3 1 S4010-0001-9 10/2004 Printer (Simplex True Alarm sensor data can be displayed on the model 4190-9013) system LCD, on a remote maintenance PC, or printed on a remote printer. With the proper operator access, a uiuuupurauiinunuuunnnioilinunn~ii TrueAlarm Service Report can be generated to list the specific details of each TrueAlarm device. This report, as Local well as the Status Report can either be displayed on the - maintenance remote maintenance PC or captured permanently by using computer a remote 80 character printer. The report samples below illustrate the format provided uui~ouaunudpmuuuuinumuueipnl on either the remote maintenance PC or a printer. This 4010 Fire Alarm information is available at the system LCD by identifying Control Panel Qne connection type per 4010, ~ selected by module choice; e; max. the specific point of interest and reading one point at a wiring distance is 300 ft (91 m) time. @ 9600 baud Model 4190-9013 is a UL Standard 864 listed 80 column, 24 pin dot matrix printer (refer to data sheet S4190-0011). Remote authorized maintenance (Model 2190-9039, a 24 VDC, 40 column printer, is computer connected via dial-up compatible with the 4010 for event printing only. Refer to Service Modem Connection data sheet 52190-0014.) RS-232 Connection Options (refer to module selection on page 6) Simplex 4010 Fire Alarm System Page 1 REPORT 3 : TrueAlarm Status Report 2:43:03 pm Mon 18-Oct-04 Zone Sensi- Almost Name Custom Label tivity Device Status Dirty M1-1 ANALOG PHOTO CLEAN ROOM 0.5 % NORMAL M1-2 ANALOG ION CLEAN ROOM 1.3 % NORMAL M1-3 ANALOG PHOTO MAIN LOBBY 2.5 % NORMAL *YES* M1-4 ANALOG PHOTO CONFERENCE ROOM 1 2.5 % NORMAL M1-10 HEA" DETECTOR GARAGE 135 F NORMAL M1-11 ANALOG PHOTO KITCHEN 3.7 % NORMAL *YES* END OF REPORT Typical TrueAlarm Status Report Information Printout and/or Maintenance PC Screen Simplex 4010 F4,.re Alarm System Page 1 REPORT 4 : TrueAlarm Service Report 2:56:09 pm Mon 18-Oct-04 Dev Alarm Avg Current/ Peak/ State Num Custom :Label at: Val % alarm % alarm 1 ANALOG PHOTO - CLEAN ROOM 0.5/ 83 67 68/ 1% 72/ 10% NOR 2 ANALOG ION - CLEAN ROOM 1.3/209 94 97/ 2% 101/ 1% NOR 3 ANALOG 0HOTO - MAIN LOBBY 2.5/185 117 117/ 0% 125/ 42% NOR 4 ANALOG ]PHOTO - CONFERENCE ROOM 1 2.5/161 93 93/ 0% 93/ 0% NOR 10 HEAT DETECTOR - GARAGE 135F/253 63/-67F 66/ 69F NOR 11 ANALOG PHOTO - KITCHEN 3.7/216 116 116/ 1% 110/ 36% NOR END OF REPORT Typical TrueAlarm Service Report Information Printout and/or Maintenance PC Screen 4 S4010-0001-9 10/2004 N2 Communications for Serial Annunciator Control. DACT, Event Reporting Module. For applications where Control for up to 6 remote Simplex Annunciator products simple event status information is required (Alarm, including 24 Point I/O Module, and LCD Annunciator. Trouble, Supervisory, and AC power failure). Includes extensive troubleshooting diagnostics. Dual RS-232 Module. Available for interfacing to a Access Port. RS-232 service port for connecting PC tools printer and a maintenance PC. for service diagnostics and for programming the CPU Single RS-232 Module with Service Modem Connection. Flash EPROM memory. Provides one port dedicated for connection to a printer, and IDNet Addressable Communications Channel. a second port dedicated for dial-in from a service computer, Addressable channel provides communications for up to typically located off-site. With an off-site computer, 250 remote addressable devices, including TrueAlarm programming changes and system diagnostics can be analog sensors and isolator bases (see descriptions on performed remotely, reducing service time for repair or page 3). reprogram. Security is maintained by password protection. Four NACs. Class B output is standard, rated for 2 A @ • • 24 VDC nominal, with solid state current protection. Class A operation is optional with the addition of an Standard 4 A Expansion Module provides two taps of adapter module. 2 A each, 28 VDC, filtered, non-regulated, similar to the NAC operation can be selected for "on-until-Silence" or standard power supply capacity. "on-until-Reset," and can be Temporal pattern, 20 or Suppression Release Power Supply provides two taps 120 bpm March Time pattern, or continuous. Each NAC of 2 A each, regulated at 24 VDC f 10%. May also be is also individually selectable to control Simplex used for other applications requiring regulated voltage. synchronized visible notification appliances and to control Use for suppression release requires a front panel audible notification appliances using SmartSyncTM mounted release applique that is provided with this power control, allowing separate audible and visible appliance supply and also may be ordered separately. operation using a common 2-wire circuit. (Class A, Style Z, SmartSync circuits require SmartSync Control Battery Meter Module provides panel mounted ammeter Module 4905-9938, refer to data sheet S4903-0010 for and voltmeter for power supply monitoring. details.) Dual Circuit Class A NAC Adapter Module mounts on the Two Auxiliary Output Circuits. Operation is main 4010 printed circuit assembly and provides the programmable for trouble, alarm, supervisory, or other additional circuitry needed for Class A operation. fire response functions. Output is one Form "C" dry Dual Circuit City Connect Module provides the interface contact each, rated 2 A @ 24 VDC. An optional relay kit required for direct wired reporting to conventional city is available for switching up to 1/2 A at 120 VAC. connection circuits. (Available with or without disconnect Power Supply. Standard output is 4 A @ 28 VDC, switches.) filtered, non-regulated. Internal system power is provided Expansion Power Distribution Module provides two separately, allowing the 4 A to be available for NAC and additional termination points for the 1/2 A auxiliary power auxiliary power tap functions. Over-current protection is output, or for one tap of the expansion power supply. solid state and self-resetting. Auxiliary Power Tap. Provides up to 1/2 A of the Relay Option Module. Provides three relays, one each for standard power supply voltage, over-current protected. Alarm, Supervisory, and Trouble. Relay contacts are selectable for normally open or normally closed and are Battery Charger. Capable of charging up to 25 Ali sealed rated 2 A @ 32 VDC maximum. lead-acid batteries (4010 cabinet mounted). A recharge time of 24 hours is typical with stable 120 VAC input. For • • Myffl applications requiring larger batteries, external Up to six of the following modules may be connected to charger/cabinet assemblies are available. the Simplex N2 serial communications but. A depleted battery cutout feature is programmable to advise 4606-9101 LCD Annunciators provide remote and/or to reduce current when battery voltage is low. acknowledge, reset, and alphanumeric status display. • • . . . . • (Refer to data sheet S4606-0001.) (The 4010 is available with a Simplex Network Interface. 24 LED Annunciator Doors are standard on ULC listed 4010 points can be declared "public.") models and are available as door-only assemblies for electronics only packages or other aftermarket applications. Network Interface, Fixed Media. Available for wired This option uses the 24 Point I/O module with all points applications. pre-assembled as LED outputs, with individual labels and Network Interface, Modular Media. Available for wired each LED is selectable as red or yellow. connections or fiber optic. Require separate media 4605 Series 24 Point 1/0 Modules are available for modules. May be both wired, both fiber optic, or one of remote mounting and provide 24 points that can be each. programmed as either general purpose switch inputs or DACT, Point Reporting Module. Provides serial output system controlled outputs. Typical applications are for information that can send location details to a remote remote annunciators and monitoring and control of other receiving station. related processes. (Refer to data sheet S4010-0002.) 1 5 S4010-0001-9 10/2004 1 1 Cat771 Descri ption Voltage Color UL Listed 4010 Fire Alarm Control Panel with: door, cabinet, power 120 VAC Beige 2 supply/battery charger, IDNet interface, 4 NACs, 2 auxiliary relays, and Red 4010-9201 external N2 communications interface; 4010-9101 and 4010-9102 Beige include internal common event reporting DACT 240 VAC Control Panel 4010-9202 Red select only 4010-9101C English ULC Listed 4010 Fire Alarm Control Panel; same as above 120 VAC Beige ( ) 4010-9101 CF French except: with 24 LED Annunciator door; and without DACT 4010-9150 UL Listed 4010 Fire Alarm Control Panel electronics only, 4010-9150C ULC English for pre-shipped cabinets, requires door and cabinet 120 VAC NA 4010-9150CF Listed French ordered separately; -9150 has event reporting DACT Optional Expansion Slot Features (two slots are available, select modules as required) Category Model Description 4010-9810 DACT Module (Common Event Reporting) Includes two, 7 ft m Ion RJ45 cables Reporting and 4010-9816 DACT Module (Point Reporting) (2.1 ) g Network Modules (select one) 4010-9821 Network Interface Module with fixed, wired connections 4010-9817 Network Interface Module, Modular; requires 2 (In/Out) media modules (see below) RS-232 4010-9811 Dual RS-232 Interface Module Communications (select one) 4010-9812 Single RS-232 Interface Module with Service Modem connection 4010-9818 Network Wired Media Module Media modules mount on the 4010-9817 module Media Modu s without im act to slot allocation s 4410-9819 Network Fiber Optic Media Module p pace. xpansion Modules (select as required) Chassis Mou 7A Category Model Description 4010-9813 4 A 120 VAC input Additional 4010-9823 Expansion Power Supply 240 VAC input Power Supply 010-9814(CF) Suppression Release Power SuPPIY. 4 A @ 24 VDC, regulated t 10%; 120 VAC in (select one) put 4010-9824 includes front panel suppression applique; CF suffix selects French 240 VAC input 4010-9820 Battery Meter Module (ammeter and voltmeter) Optional Features (select one) 4010-9825 24 VDC Expansion Power Distribution Module, provides two additional termination points for an expansion power supply tap or the auxiliary power output 4010-9806 Dual Circuit Class A (Style Z) NAC Adapter Module, two maximum Optional Features 4010-9809 Dual Circuit City Connect Module (select as Select one indicated) 4010-9829* Dual Circuit City Connect Module w/o disconnect switches maximum 4010-9803 Relay Option Module Accessories Category Model Description 4010-9826 120 VAC Auxiliary Relay Kit, allows one auxiliary relay to control up to 1/2 A @120 VAC, select as required; 2 maximum 4010-9830 Suppression Release Applique, required for suppression release applications; suffix CAF Optional Features (CAF) selects a French applique 2975-9801 Semi-flush trim, beige, 1-7/16" (37 mm) wide 2975-9802 Semi-flush trim, red, 1-7/16" (37 mm) wide 'IPA Batteries 2081-9272 6.2 Ah Battery, 12 VDC (required if 2081-9274 10.0 Ah Battery, 12 VDC batteries are 2081-9288 12.7 Ah Battery, 12 VDC internal; select one size; two batteries 2081-9275 18 Ah Battery, 12 VDC; NOTE: This battery size will not allow bottom entry conduit are required) 2081-9287 25 Ah Battery, 12 VDC Cabinets (select 2975-9215 Red Cabinet Dimensions: 22" H x 18" W x 5-3/8" D one if pre-shipped) 2975-9214(CF) Beige Cabinet; CF suffix has French labels (559 mm x 457 mm x 137 mm) 4010-9858 Red Door with dress panel Dimensions: 22" H x 18" W x 5/8" D Doors (select one 4010-9857(CF) Beige Door with dress panel; CF has French labels (559 mm x 457 mm x 16 mm) if pre-shipped or for use with 4010-9860 Beige Door with 24 LED Annunciator and dress panel; Dimensions: 22" H x 18" W x 4010-9150) (CAF)* CAF suffix selects French for ULC applications 1-23/32"D (559 mm x 457 mm x 4010-9861 * Red Door with 24 LED Annunciator and dress panel 44 mm) [see also S4010-00021 As of document revision date: 4010-9829 is not ULC listed; 4010-9860 and 4010-9861 are listed by UL and ULC and approved by CSFM and FM; 4010-9860CAF is ULC listed and FM approved only. 6 S4010-0001-9 10/2004 Input Power Requirements Voltage Range Frequency Maximum Current AC Input, 120 VAC base models 102 to 132 VAC 60 Hz 2 A AC Input, 240 VAC base models 204 to 264 VAC 50/60 Hz 1 A AC Input with 120 VAC expansion power supply 102 to 132 VAC 60 Hz 4 A AC Input with 240 VAC expansion power supply 204 to 264 VAC 50/60 Hz 2 A Environmental Operating Temperature Range 32° to 120°F (0° to 49° C) Operating Humidity Range up to 93% RH, non-condensing @ 100.4° F (38° C) maximum Output Ratings Standard Power Supply Output 4 A total @ nominal 28 VDC Auxiliary Power Tap 1/2 A maximum of standard power Output switches to battery supply voltage backup during mains failure or Expansion Power Supply Output' Additional 4 A @ nominal 28 VDC brownout conditions Suppression Release Power Supply Output " Additional 4 A @ 24 VDC ±10% * Each power supply provides two output taps of 2 A each. Current Ratings for Optional Modules and Remote LCD Annunciator Model Module Supervisorv Alarm Current Current 4010-9810 DACT (Common Event Reporting) 40 mA 40 mA 4010-9816 DACT (Point Reporting) 40 mA 40 mA 4010-9821 Network, wired communications 125 mA 125 mA 4010-9817 Network Modular, add media cards separately 24 mA 24 mA 4010-9818 Network Wired Media 47 mA 47 mA 4010-9819 Network Fiber Optic Media 36 mA 36 mA 4010-9811 Dual RS-232 75 mA 75 mA 4010-9812 Single RS-232 with Service Modem 100 mA 100 mA 4010-9806 Dual Class A NAC Adapter 0 mA 0 mA 4010-9809 Dual Circuit City Connect 20 mA 36 mA 4010-9829 Dual Circuit City Connect w/o disconnect switches 20 mA 36 mA 4010-9803 Relay Option Module 10 mA 37 mA 4010-9860 83 mA 4010-9861 24 LED Annunciator door 60 mA all LEDs on) & ULC 4010s ( ) 4606-9101 Remote LCD Annunciator (refer to data sheet S4606-0001) 65 mA 140 mA System Current (supplied separate from power supply output) Base System with: Supervisorv Alarm Current' Current" no IDNet devices 195 mA 295 mA 50 IDNet devices 230 mA 330 mA 100 IDNet devices 265 mA 365 mA 150 IDNet devices 300 mA 400 mA 200 IDNet devices 335 mA 435 mA 250 IDNet devices 370 mA 470 mA Current Calculation Information: 1. To determine total supervisory current, add currents of modules in panel to base system value and all auxiliary loads. 2. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all auxiliary loads. 7 S4010-0601-9 10/2004 E%T N2 u IDN"1 NAC 1 NAC 2 NAC 3 NAC < w 0 o Qo O iFw T., 4010-9820 O O; :O O TB3 TBC 4010-9809 Meter Module ' 4010-9806 4010-9806 n or -9829 City Module ~ or Expansion Class A Class A y 4010-9825 Slots 1 & 2 Module Module or 24 VDC Power 4010 -9803 Distribution Relay Module Block O O - o a o o 0 0 o= o. -T ` o`o o a O 0 3, T O O O O O O O 40104098--9819814 ~ ^ O O O O_ O O 4010-9823, or 4010-9824 O Expansion Power Supply III OI 0~~ QQ nn nn p o 0 AUX AUX, AU%2 BATTERY POWER / . _ _ - - _ I - - - 7-3/32" Typical conduit entry area (180 mm) (cut holes as required) o Standard 1-19/32" door profile (40 mm) 6-1/4" (159 mm) 3/4" 5-1/2" 18" (457 mm)~ Annunciator (19 mm) (140 mm) door profile Wall thickness guides for 1 1/2" (13 mm) wall board Standard Door, c~ ® F_ -T 1 5/8" (16 mm) thick Wall thickness guides for _ C5/8" (16 mm) wall board) ~I i Internal straps are Annunciator Door, provided for wiring o a a Too ' 1-23/32" (44 mm) thick management 00000 oo (2 each side) 21" 09®9- 00900 f (533 mn, Door and exposed cabinet dimension for semi-flush mount 2-15/32"(63 mm) 14-1/2"(368 mm)?' Knockout screw/nail holes Battery Area (for semi-flush mount) No conduit entry or wiring in this area 0 O ~ Wall board position reference Shaded area is for non-power limited wiring for semi-flush mount Tyco, Simpler, the Simpler. logo, TrueAlarm, WAUTEST, IDNet, SmartSyne, and TrueAlert are trademarks of Tyco International AG or its affiliates in the U.S. and/or other countries. NFPA 71 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). ~3 Simplex Tyco Safety Products Westminster " Westminster, MA " 01441-0001 • USA S4010-0001-9 10/2004 ® www.tycosafetyproducts-usa-wm.com 02004 Tyco Safety Produce Westminster. A11 rights reserved . All specif cations and other information shown were nvrent as ofdocvonlent revision date acid are subject to change withotd notice. 93,,Simplex Multi-Application Peripherals UL, ULC Listed; FM, CSFM, MAPNET II® or IDNetTIM Communicating Devices and MEA (NYC) Approved* Addressable Manual Stations Individually addressable manual fire alarm ! s stations with: - • Power and data supplied via MAPNET II or IDNet addressable communications using a single wire LL DOV r pair** • Operation that complies with ADA requirements • Pull lever that protrudes when alarmed • Break-rod supplied (use is optional) i Models are available with single or double action (breakglass or push) operation 4099-9001 Addressable Manual Station • UL listed to Standard 38 (front and side view) Compatible with the following Simplex control panels: 1 . `y R : r j ~'t Model Series 4010/4100/4100U/4120/4020 fire alarm f° control panels equipped with either IDNet or KEY MAPNET 11 communications 10 ERATED • Model Series 2120 communicating device transponders CDTs equipped with MAPNET II communications LL = Compact construction: 4099-9002 4099-9003 With 2099-9828 • Electronics module enclosure minimizes dust Breakglass Push Institutional infiltration Cover kit • Allows mounting in standard electrical boxes ' - • Screw terminals for wiring connections Activation of the Simplex 4099-9001 single manual station requires a firm downward pull to activate the Tamper resistant reset key lock (keyed same as alarm switch. Completing the action breaks an internal Simplex fire alarm cabinets) plastic break-rod (visible below the pull lever, use is Multiple mounting options: optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull • Surface or semi-flush with standard boxes or requirements needed for easy activation. The pull lever matching Simplex boxes latches into the alarm position and remains extended out • Flush mount adapter kit of the housing to provide a visible indication. • Adapters are available for retrofitting to commonly Double Action Stations (Breakglass) require the available existing boxes operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. The Simplex model 4099-9001 addressable station Double Action Stations (Push Type) require that a combines the familiar Simplex manual station housing spring loaded interference plate (marked PUSH) be with a compact communication module that is easily pushed back to access the pull lever of the single action installed to satisfy demanding applications. Its integral station. individual addressable module (IAM) constantly monitors status and communicates changes to the connected control Station reset requires the use of a key to reset the panel via MAPNET II or IDNet communications wiring. manual station lever and deactivate the alarm switch. (If the break-rod is used, it must be replaced.) This product has been approved by the California State Fire Marshal (CSFM) pursuant to Station testing is performed by physical activation of Section 13144.1 of the California Health and Safety Code. See CSFM Listing the pull lever. Electrical testing can be also performed by 7150-0026:224 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for unlocking the station housing to activate the alarm switch. use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products MAPNET II and IDNet addressable communications designs are protected by U.S. Westminster. Patent No. 4,796,025. i S4099-0001-6 10/2003 Addressable Manual Stations Model Description 4099-9001 Single action \4099-9002 Double action, Break lasso eration Addressable manual station, red housing with white letters and white pull lever 4099-9003 Double action, Push operation Accessories Model Description Reference 2975-9178 Surface mount steel box, red Refer to page 3 for dimensions 2975-902:2 Cast aluminum surface mount box, red 2099-9813 Semi-flush trim late for double an switch box, red Typically for retrofit, refer to page 4 2099-9814 Surface trim late for Wiremold box V5744-2, red 2099-9819 Flush mount adapter kit, black Refer to page 4 for details 2099-982.0 Flush mount adapter kit, beige 2099-9803 Replacement break lass 2099-9804 Replacement break-rod 2099-9828 Institutional cover kit for field installation on 4099-9001 Power and Communications MAPNET II or IDNet, 1 address per station, up to 2500 ft (762 m) from fire alarm control panel, u to 10,000 ft 3048 m total wiring distance (including T-Taps) Address Means Di switch, 8 position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire UL Listed Temperature Range 32° to 120° F 0° to 49° C intended for indoor operation Humidity Range U to 93% RH at 100° F 38° F Housing Color Red with white raised lettering Material Housing and pull lever are Lexan of carbonate orequal Pull Lever Color White with red raised lettering Housing Dimensions 15"H x 3-3/4"W x 1"D 127 mm x 95 mm x 25 mm . rllcffffs• • Single Gang Box Mount 4" Square Box Mount Single gang box, 2-1/2" deep 4" (102 mm) square box, 2-1/8" (54 mm) minimum (64 mm), RACO #500 or equal depth, RACO #231 or equal (supplied by others) (supplied by others) 0 Wj Mount flush or with o 1/1 6" (2 mm) t maximum extension 0 (44" 0 DO NOT RECESS Square box th cover plat0 P~A Station FIRE ALARM side view Single gang cover plate, 3/4" (19 mm) extension, RACO #773 PULL DOWN or equal (supplied by others) l Single gang box outline Wall surface a - !I l Semi-Flush Mount Side View £i Simplex 2 S4099-0001-6 10/2003 2975-9178 Box 2975-9022 Cast Box Preferred Mounting. For 5-3/16" H x 4" W x 2-3116" D 5" H x 3-7/8" W x 2-3/16" D (132 mm x 102 mm x 56 mm) (127 mm x 98 mm x 56 mm) surface mounting of these (ordered separately) addressable manual stations, the (ordered separately) \ preferred electrical boxes are shown in the illustration to the right. 0 0 0 0 Additional Mounting Knockouts located Reference. Refer to page 4 for top and bottom Wiremold box mounting compatibility. FIRE 1 j ALARM 0 0 PULL DOWN 1j- i Access for 3/4" threaded 5" - conduit located top and bottom (127 mm) Li- ~j 's Simplex' 4- - 1 1" (25.4 mm) 3-3/4" (95 mm)? 4099 Series Addressable Manual Station Refer to NFPA 72, the National Fire Alarm Code and all applicable local 1-1/4" codes for complete requirements for (32 mm) Simplex 2975-9178 box manual stations. The following Field wiring (shown for r reference) g (shown for reference) summarizes the basic requirements. f 1. Stations shall be located in the normal path of exit and distributed i in the protected area such that they Address setting under - are unobstructed and readily resealable label (accessible with cover open) accessible. 2. Mounting shall be with the (67 mm) operable part not less than 3-1/2 ft (1.1 m) and not more than 4-1/2 ft Station cover hinges open for (1.37 m) above floor level. installation access 3. At least one station shall be provided on each floor. Additional Switch wiring stations shall be provided to obtain a travel distance not more than p~ 200 ft (61 m) to the nearest station from any point in the building. 4. When manual station coverage appears limited in any way, additional stations should be installed. 3 S4099-0001-6 10/2003 For retrofit and new installations, additional 0 0 Wiremold compatible mounting boxes receptacle box and the required adapter plates 2099-9814 Surface trim model V5744-2 for Wiremold box (supplied by are shown in the illustration to 5-1/8" H x 5" W others) the right. (130 mm x 127 mm) o O O O Two gang switch box, each - 3" H x 2" W x 2-3/4" D ~fL (76mmx51 mmx70mm) (supplied by others) 4099-9001IDNet U'LL DOWN addressable station - lc=~ o10 U U 2099-9813 Semi-flush trim for 2 gang o d switch box, 6" H x 4-1/2" W (152 mm x 114 mm) I e 11 11 1111 111 11 Flush mount adapter kit 2099-9819, Black 4 2099-9820, Beige Box must be recessed into wall 1" to 1-1/8" (25.4 mm to 29 mm) 54 L-; (203 mm) to h, o Hole cutout must be a 4 t PULL DOWN minimum of 6" H by 5" W 6" (152 mm by 127 mm) r' ~ / (152 s: 1 mm) 0 -i ' - l t { 1~4't~ M1 'f , 4-11/16"(119 mm) square box, 2-1/8" i 1' t _ I (54 mm) minimum Wall depth (by others) 4-3/4"(121 mm) surface 6-3/4" (171 mm) Front View Side View Tyco, Simplex, the Simplex logo, MAPNET II, and IDNet are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Lexan is a trademark ofthe General Electric Co. Wiremold is a trademark of the Wiremold Company. f 3 Simplex Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4099-0001-6 10/2003 ® www.tycosafetyproducts-usa-wm.com P2003 Tyco Safety A odto°ts Westminster. All rights reserved. All specijications and other information shown were nu-rent as ofdocmnent revision date and are s !bject to change without notice. 13,,Simplex TrueA/arum Analog Sensing UL, ULC Listed, FM, CSFM, TrueAlarm Analog Sensors - Photoelectric, and MEA (NYC) Approved* Ionization, and Heat; Compatible Bases and Accessories TrueAlarm® analog sensing provides digital r r transmission MAPNET II ® o~ DNet~g two-wire sensor lcommunications Fire alarm control panel provides: Individual sensitivity selection for each sensor A I Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements - Peak value logging allowing accurate analysis for sensitivity selection 4098-9714 TrueAlarm Photoelectric Automatic, once per minute individual sensor Sensor Mounted in Base calibration check that verifies sensor integrity 07M ff M. • Automatic environmental compensation • Display of sensitivity directly in percent per foot Digital Communication of Analog Sensing. • Multi-stage alarm operation TrueAlarm analog sensors provide an analog measurement that is digitally communicated to the host • Ability to display and print detailed sensor control panel using Simplex addressable communications. information in plain English language At the control panel, the data is analyzed and an average Photoelectric smoke sensors: value is determined and stored. An alarm or other • Seven levels of sensitivity from 0.2% to 3.7% abnormal condition is determined by comparing the sensor's present value against its average value and time. Heat sensors: Intelligent Data Evaluation. Monitoring each sensor's • Fixed temperature sensing average value provides a continuously shifting reference Rate-of-rise temperature sensing point. This software filtering process compensates for • Utility temperature sensing environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new Ionization smoke sensors: activity. With this filtering, there is a significant reduction • Three levels of sensitivity; 0.5%, 0.9% and 1.3% in the probability of false or nuisance alarms caused by For use with Simplex e: shifts in sensitivity, either up or down. • 4010, 4020, 4100, 4100U, and 4120 Series control Control Panel Selection. Peak activity per sensor is panels stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the • Universal Transponders and 2120 TrueAlarm CDTs host control panel, selectable as more or less sensitive as equipped for MAPNET II operation the individual application requires. Magnetic test feature Timed/Multi-Stage Selection. Sensor alarm set points Functional and architecturally styled chamber can be programmed for timed automatic sensitivity enclosure: selection (such as more sensitive at night, less sensitive • Louvered design enhances smoke capture by directing during day). Control panel programming can also pro vide multi-stage operation per sensor. For example, a 0.2 /n flow to chamber level may cause a warning to prompt investigation while a • Entrance areas are minimally visible when ceiling 2.5% level may initiate an alarm. mounted Sensor Alarm and Trouble LED Indication. Each Optional accessories include remote LED alarm sensor base's LED pulses to indicate communications indicator and output relays with the panel. If the control panel determines that a UL listed to Standard 268 sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel Refer to page 4 for ULC listing status. These products have been approved by the and that sensor base's LED will be turned on steadily. California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California During a system alarm, the control panel will control the Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270- 0026:216, and 7300-0026:217 for allowable values and/or conditions concerning LEDs such that an LED indicating a trouble will return to material presented in this document. It is subject to re-examination, revision, and pulsing to help identify the alarmed sensors. possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact your local Simplex product " TrueAlarm analog sensors are protected by one or more of the following U.S. Patents: supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,710,541; D383,407; D388,352; 0392,573. are the property of Tyco Safety Products Westminster. MAPNET II and IDNet addressable communications designs are protected by U.S. Patent No. 4,796,025. S4098-0019-9 9/2003 TrueA/arm Sensor Bases and Accessories - • TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the Base mounted address selection: detachable photoelectric, ionization, or heat sensors. Each • Address remains with its programmed location sensor's output is digitized and transmitted to the system • Accessible from front (dipswitch under sensor) fire alarm control panel every four seconds. Automatic identification provides default sensitivity Since TrueAlarm sensors use the same base, different when substituting sensor types sensor types can be easily interchanged to meet specific Integral red LED for power-on (pulsing), or alarm or location requirements. This feature also allows intentional trouble (steady on) sensor substitution during building construction. When Locking anti-tamper design conditions are temporarily dusty, instead of covering the Magnetically operated functional test smoke sensors (causing them to be disabled), heat sensors Mounts on standard outlet box may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a 4098-9792, Standard sensor base default sensitivity providing heat detection for building 4098-9789, Sensor base with wired connections for: protection at that location. • 2098-9808 Remote LED alarm indicator or 4098-9822 relay (unsupervised) 4098-9791, Sensor base with supervised relay driver output (not compatible with 2120 CDT): Electrical Box Requirements: (boxes are by others) • Relay operation is programmable and can be manually WithoutLeley: 4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep operated from control panel With reW : 4" octagonal or 4" square, 1-1/2" deep, • Use with remote mount 2098-9737 relay with 1-1/2" extension ring • Also includes wired connections for remote LED 4" (102 mm) Square Box 4" (102 mm) Octagonal Box alarm indicator or 4098-9822 relay Surface mount reference 2098-9737, Remote or local mount supervised relay: • DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited 1-1/2"(38 mm) rating of 3 A @ 120 VAC (requires external 24 VDC minimum box depth Flush mount reference, mount even with final coil power) surface, or with up to 1/4" (6.4 mm) maximum recess 4098-9822, LED Annunciation Relay: 2 098-9737 Relay (mounts in 4098-9822 Relay (mounts • Activates when base LED is on steady, indicating base electrical box or remotely) in base electrical box) local alarm or trouble • DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Relay Size: 2-1/2"X 1-1/2" X 1" (3.75 cubic inches) • Required for surface or semi-flush mounting to (64 mm X 38 mm X 25.4 mm) 4" square electrical box and for surface mounting to NOTE: Review total wire count, wire size, and accessories 4" octagonal box being wired to determine required box volume. • Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 6-3/8" (162 mm) 2098-9808, Remote red LED Alarm "S Indicator: t 4098-9832 Adapter Plate, required for 1/4" mounting to surface mounted boxes • Mounts on single gang box ALARM (6.4 mm) a d !C square flush box (shown in illustration to right) tizIt 4-7/8" (124 mm) - 15/16" s35rnplex (24 mm) 0 TrueAlarm Bases 4098-9789, -9791, 8 -9792 2 S4098-0019-9 9/2003 TrueA/arm Sensors , t • : 0- "M TrueAlarm photoelectric sensors use a stable, pulsed Sealed against rear air flow entry infrared LED light source and a silicon photodiode Interchangeable mounting receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available EMI/RFI shielded electronics for each individual sensor, ranging from 0.2% to 3.7% per Heat sensors: foot of smoke obscuration. Sensitivity is selected and • Selectable rate compensated, fixed temperature monitored at the fire alarm control panel. sensing with or without rate-of-rise operation The sensor head design provides 360° smoke entry for • Spacing distance between heat sensors: optimum response to smoke from any direction. A built-in Fixed Temp. FM Spacing, Either Foxed screen keeps insects from entering the smoke chamber. Setting UL Spacing Temperature Setting Due to its photoelectric operation, air velocity is not 15 ft x 15 ft (4.6 m) fixed normally a factor, except for impact on area smoke flow. 135° F (57.2° C) 60 ft (18.3 m) temperature only; 30 ft x 30 ft (9.2 m) fixed 4-7/8" (124 mm) 155° F (68° C) 40 ft (12.2 m) temperature with rate-of-rise LED status indicator Smoke Sensors: 2-1/8" • Photoelectric or ionization technology sensing (54 rn • 360° smoke entry for optimum response - TrueAlarm heat sensors are self-restoring and provide rate 4098-9714 Photoelectric Sensor with Base compensated, fixed temperature sensing, selectable with "M fflo or without rate-of-rise temperature sensing. Due to its t small thermal mass, the sensor accurately and quickly TrueAlarm Ionization sensors use a single radioactive measures the local temperature for analysis at the fire source with an outer sampling ionization chamber and an alarm control panel. inner reference ionization chamber to provide stable Rate-of-rise temperature detection is selectable at the operation under fluctuations in environmental conditions control panel for either 15° F (8.3° C) or 20° F (11.1° C) such as temperature and humidity. Smoke and invisible per minute. Fixed temperature sensing is independent of combustion gases can freely penetrate the outer chamber. rate-of-rise sensing and programmable to operate at With both chambers ionized by a small radioactive source 135° F (57.2° C) or 155° F (68° Q. In a slow developing [Am 241 (Americium)], a very small current flows in the fire, the temperature may not increase rapidly enough to circuit. The presence of particles of combustion will cause operate the rate-of-rise feature. However, an alarm will be a change in the voltage ratio between chambers. This initiated when the temperature reaches its rated fixed difference is measured by the electronics in the sensor temperature setting. base and digitally transmitted back to the control panel for processing. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range Three levels of sensitivity are available for each from 32° F to 155° F (0° C to 68° Q. This feature can ionization sensor: 0.5, 0.9, and 1.3% per foot of smoke provide freeze warnings or alert to HVAC system obscuration. problems. (Refer to specific panels for availability.) 4-7/8" (124 mm) 4-7/8" (124 mm) LED status indicator 2-1/8" LED status indicator (54 mm) 2-3/8" (60 mm) 4098-9717 Ionization Sensor with Base 0•• • 4098-9733 Heat Sensor with Base Sensor locations should be determined only after careful consideration of the physical layout and contents of the WARNING: In most fires, hazardous levels of smoke area to be protected. Refer to NFPA 72, the National Fire and toxic gas can build up before a heat detection Alarm Code On smooth ceilings, smoke sensor spacing device would initiate an alarm. In cases where Life of 30 ft (9.1 m) may be used as a guide. For detailed Safety is a factor, the use of smoke detection is highly application information, refer to 4098 Detectors, Sensors, recommended. and Bases Application Manual (574-709). 3 S4098-0019-9 9/2003 A TrueAlarm Sensor Bases* Model Description Compatibility Mounting Requirements 4098-9792 (C) Standard Sensor Base, no options Sensors 4098-9714, -9733, & 9717 4" octagonal or 4" square box, 1-1/2" min. depth; or single an box, 2" min. depth :sensor Base with connections for Sensors 4098-9714, -9733, & -9717 4098-9789 (C) Remote LED Alarm Indicator or 2098-9808 remote LED alarm Unsupervised Relay indicator or 4098-9822 relay 4" octagonal or 4" square box Sensor Base with connections for Sensors 4098-9714 -9733 & -9717 fie: Box depth requirements depend Supervised Remote Relay and 2098-9737 remote relay (supervised) on total wire count and wire size, refer to 4098-9791 (C) connections for Remote Alarm accessories list below for reference. Indicator or Unsupervised Relay 2098-9808 remote alarm indicator or 4098-9822 relay unsu ervised TrueAlarm Sensors Model Description Compatibility Mounting Requirements 4098-9714 (C) Photoelectric Smoke Sensor 4098-9717 (C) Ionization Smoke Sensor Bases 4098-9792, 4098 9789, and 4098-9791 Refer to base requirements 4098-9733 (C) Heat Sensor TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements Remote Mounting requires 4" octagonal or 2098-9737 Supervised Relay, mounts remote For use with 4098-9791 base 4" square box, 1-1/2" minimum depth or in base electrical box Base Mounting requires 4" octagonal box, 2-1/8" deep with 1-1/2" extension ring 2098-9808 Remote Red LED Alarm Indicator Single gang box, 1-1/2" minimum depth on single an stainless steel late Relay, tracks base LED status Bases 4098-9789 and 4098-9791 4098-9822 C 4" octagonal box, 2-1/8" deep with 1-1/2" ( ) (unsupervised, mounts only in base extension ring electrical box Required for surface or semi-flush 4098-9832 Adapter Plate Bases 4098-9792, -9789, & -9791 mounted 4" square box and for surface mounted 4" octagonal box Refer to data sheet S4098-0028 for Sounder Base information. Refer to Installation Instructions 574-707 and Application Manual 574-709 for additional information. ULC listed model numbers are desiqnated by (C) and require a "C" suffix such as 4098-9792C. EM M • General Operating Specifications Communications and Sensor Supervisory Power MAPNET II or IDNet, auto-select, 24-40 VDC w/data, 400 9A typical, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mmz to 2.08 mmz) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mmz ) UL Listed Temperature Range 32° to 100° F (0° to 38° C) Operating with 4098-9717 or 4098 -9733 32° to 122° F (0" to 50° C) Temperature Range with 4098-9714 15° to 122° F (-9° to 50° C) Humidity Range 10 to 95% RH Smoke Sensor 4098-9714, Photoelectric Sensor Air velocity = 0-2000 ft/min (0-610 m/min) Ambient Ratings 4098-9717, Ionization Sensor Air velocity = 0-100 ft/min (0-122 m/min); Altitude is up to 8000 ft (2.4 km) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 PA, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789 and 4098-9791 (see page 2 for contact ratings) Externally SuppliEd Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply Tyco, Simplex, the Simplex logo, TrueAlarm, MAPNET II, and IDNet are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). ®Simplex Tyco Safety Products Westminster - Westminster, MA • 01441-0001 • USA S4098-0019-9 9/2003 www.tycosafetyproducts-usa-wm.com © 2003 Tvco Sa%ty Produce Westminster. All rights reserved. All specifications and other information shomi xere current as ofdocu meet revision date and are subject to change without notice. 93,Simplex Multi-Application Peripherals UL, ULC Listed; FM, CSFM, MAPNET II0 and IDNetTM Communicating Devices, and MEA (NYC) Approved* Individual Addressable Modules (IAMs) r MAPNET II or IDNet addressable communications flSiniMex supply both data and power over a single wire pair s'MPttt scut RtfoROtR co 4090-9001 to provide": uPlArlslultw ~ INS/. Ik5lq 511 • Supervised Class B monitoring of normally open, dry Dpil coop contacts ? e • Total wiring distance from IAM to supervision t o 0 0o C resistor(s) of up to 500 ft (152m) • Monitored connection is compatible with Simplex 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications 4090-9001 Supervised [AM (shown approximately 3/4 size) For use with following Simplex control panels: • Model Series 4010/4100/4100U/4120/4020 fire alarm control panels equipped with either IDNet or MAPNET II communications • Model Series 2120 communicating device transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: • Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box • Screw terminals for wiring connections • Visible LED flashes to indicate communications • Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, 4090-9051 Supervised IAM ordered separately) (shown approximately 3/4 size) Model 4090-9051: • Encapsulated design for extended exposure to high humidity (LED is not present on this model) I - • • • Color coded 18 AWG leads for wiring Individual addressable modules (IAMs) receive IDNet communications provides current limited both power and communications from a two-wire monitoring: MAPNET II or IDNet circuit. They provide location • Provides monitoring of tamper switch (supervisory) and specific addressability to a single initiating device (such waterflow switch (alarm) on same circuit using one point as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location • Available with IDNet communications only by monitoring normally open dry contacts and the wiring Multiple opr ation modes are available and are to an end-of-line resistor. selectable at the control panel: Model 4090-9001 is packaged in a thermoplastic • Contact closure status; can be tracked housing and provides screw terminal connections and a • Momentary contact closure conditions can be selected at status indicating LED. the panel to be latched or tracked (not available with the Model 4090-9051 is an encapsulated package with wire 2120 CDT) leads. It does not provide a status indicating LED. UL listed to Standard 864 ` These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for MAPNET II and IDNet addressable communications designs are protected by U.S. use - City of New York Department of Buildings - MEA35-93E. Additional listings may be Patent No. 4,796,025. applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4090-0001-7 3/2004 VIM • • M• Contact Closure. Closure of the monitored contact(s) For use with IDNet communications only, these initiates an alarm or other response as programmed at the IAMB can sense normal, open circuit, short circuit, and fire alarm control panel. An open in the monitored circuit current limited conditions. With the proper end-of-line wiring will cause a trouble to be reported. and current limiting resistors, dual functions such as Panel Selections. Selections can be made at the control tamper switch and waterflow switch monitoring can be panel to maintain the alarm condition if the initiating determined and communicated by a single addressable device contacts are momentary, such as from a point. rate-of-rise heat detector, or to track the device contact status (not available with the 2120 CDT). odel Number Description 4090-9001 Supervised IAM, mounted in thermoplastic housing with screw terminals; see applicable options below 4090-9051 Supervised IAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Number Description 4090-9806 Trim plate with LED viewing window, requires For semi-flush mounted box 4090-9810 mounting bracket, includes mounting 4090-9807 screws; galvanized steel For surface mounted box 4090-9810 Mounting bracket, mounts IAM to electrical box and provides screw holes for trim plate, required for optional trim plates • Electrical Power and Communications MAPNET II or IDNet, auto selected, 1 address per IAM Input Requirements Normally open, dry contacts 4090-9001 Screw terminals for in/out wiring, 18 to 14 AWG wire Wire Connections (0.82 mm to 2.08 MM 2) 4090-9051 Color coded wire leads, 18 AWG (0.82 mmz), 8" long (203 mm) Supervision Resistor 6.8 ko, 1/2 W NOTE: Refer to installation instructions 574-331 (-9001), 574-572 (-9051) and Resistors for Current Limited Operation 1.8 kf2 and 4.7 kQ, 1/2 W field wiring diagrams 841-804 and (for use with IDNet communications only 842-073 for additional information. Wiring Distances 500 ft (152 m) maximum without protectors Distance from IAM to Contacts 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, 2500 ft (762 m) maximum from fire alarm control panel ,MAPNET II or IDNet Communications 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical Dimensions 4090-9001 1-9/16" W x 1-3/4" H x 1-1/4" D (40 mm x 44 mm x 32 mm) 4090-9051 1-9/16" W x 1-9/16" H x 9/16" D (40 mm x 40 mm x 14 mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) 2 S4090-0001-7 3/2004 4090-9001 IDNet Field wiring shown supervised IAM for reference m 5LiM I9 9_(OPDIP f0. V 900 Pv]Iuo!o INS!. 101. SII-]!I rob[ LED viewing port 9 ~7CC _pp~~ Single gang electrical 9 box 2-1/2" (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate 0 O O Light pipe for LED viewing 4-1/4" O 0 4-1/2" (108 mm) _ (114 mm) O 2-1/2" 2-13/16" (64 mm) ~(72 mm)~ 4090-9806, Trim plate for 4090-9807, Trim plate for 4090-9810 Mounting semi-flush mounted box surface mounted box bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 3 S4090-0001-7 3/2004 M. 19 Address setting is at rear of housing 4090-9051 Encapsulated Supervised IAM Single gang electrical box 2-1/2" (64mm) minimum depth (supplied by others) Single gang blank cover plate and mounting screws (supplied by others) Tyco, Simplex, the Simple): logo, MAPNETII, and IDNet are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. 93®Simplex Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4090-0001-7 3/2004 www.tycosafetyproducts-usa-wm.com ©1004 Tyco Safety- Prodta,tr Westminster. All rights reserved. All specifications and other information shown were crurent as ofdoaanent revirion date and are subject to change without notice. 9;,Simplex TrueAlere Multi-Candela Notification Appliances UL, ULC Listed, FM Visible Notification Appliances with Horn and Synchronized and CSFMApproved* Flash; Non-Addressable, SmartSynCTMI Operation Compatible Audible/visible (AN) notification appliances with R" efficient electronic horn and high output xenon- l strobe, available for wall or ceiling mount [ • Operation is compatible with ADA requirements (refer to important installation information on page 3) [ • Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: • Horns that are controlled separately from strobes on the r 11 same two-wire circuit • "On-until-silenced" and "on-until-reset" operation on the same two-wire pair F I R • Horn control that can be selected to be temporal coded, march time coded, or on continuously • Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate • Class B (Style Y) operation requires connection to a compatible SmartSync NAC or to SmartSync Control Wall and Ceiling Mount A/Vs Module (SCM) 4905-9938 . • Class A (Style Z) operation when connected to the 4905-9938 SCM or with 4100U series fire alarm control Multi-Candela TrueAlert ANs with horn and panel NACs synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are Wall mount ANs features: both impact and vandal resistant and provide a convenient • Wiring terminals are accessible from the front of the strobe intensity selection. Since each model can be housing providing easy access for installation, selected for strobe intensity output, on-site model inspection, and testing inventory is minimized and changes encountered during • Covers are available separately to convert housing color construction can be easily accommodated. Optional adapters and wire guards: Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or • Wall mount AN adapters are available to cover surface 4" square standard electrical box. The cover can be mounted electrical boxes and to adapt to Simplex quickly removed (a tool is required) and covers are 2975-9145 boxes available separately for color conversion. • UL listed red wire guards are available for wall or ceiling mount A/Vs Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is determined by model number. Visible notification appliar.:;e (strobe): Strobe Intensi-tv Selection. 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selecticai jumper secured During installation, a selection plug at the back of the behind strobe housing housing determines the desired strobe intensity. An • UL listed to Standard 1971 attached flag with black letters on a highly visible yellow Regulated circuit design ensures consistent flash output background allows the selected intensity to be seen at the side of the strobe lens. and provides controlled inrush current ' This product has been approved by the California State Fire Marshal (CSFM) pursuant to Audible notification appliance (horn): Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:317 for allowable values and/or conditions concerning material presented in this • Low current, 24 VDC electronic horn with harmonically document. It is subject to re-examination, revision, and possible cancellation. This product was not approved by MEA (NYC) as of document revision date. Refer to page 2 for listing rich output sound suitable for either coded or steady status of wire guards. Additional listings may be applicable; contact your local Simplex operation product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. • UL listed to Standard 4ti4 " Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5,559,492 and SmartSync homistmbe operation is protected under U.S. Patent No. 6,281,789. S4906-0002-2 9/2004 A . . Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy, location, local codes, and proper applications provide the ability to activate both the horn and strobe on of. the National Fire Alarm Code (NFpA 72), ANSI the same NAC and then allow the horn to be silenced A117. 1; the appropriate model building code: BOCA, while the strobe remains flashing. The horn operates as ICBO, or SBCCI; and the application guidelines of the "on-until-silenced" while the strobe operation is Americans with Disabilities Act (ADA). "on-until-reset." Multiple Strobes. When multiple strobes and their . 41000 and 4010 Fire Alarm Control Panels (refer to reflections can be seen from one location, synchronized data sheet S4010-0001 for details; refer to data sheet flashes reduce the probability of photo-sensitive reactions 54100-0031 for basic 4100U information) as well as the annoyance and possible distraction of . 4009 IDNet NAC Extender (refer to data sheet random flashing. The multi-candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation . SmartSync Control Module (SCM) 4905-9938 (refer to NAC. data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Multi-Candela A/Vs Model Mounting Housing Color "FIRE" Lettering Description 4906-9127 Red White Nall Horn with Multi-Candela Strobe; strobe intensit selectable as: 4906-9129 White Red y 15, 30, 75, or 110 candela; operates with SmartSync two-wire 4906-9128 (veiling Red White control 4906-9130 White Red Wall Mount A/V Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep 5-3/8" H x 5-1/4" W x 1-5/8" D surface mounted boxes (136 mm x 133 mm x 41 mm) 4905 9940 White depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (10:2 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount ANs Model Description Dimensions 4905-9994 Red cover with white "FIRE" lettering 5-1/8" H x 5" W x 1-1/2" D 4905-9995 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimensions 4905-9961* Wall mount red wire guard with mounting plate, compatible with semi-flush 6-1/16" H x 6-1/16" W x 3-1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2" x 6-1/8" x 3" (216 mm x 156 mm x 76 mm) 4905-9928- Ceiling Red Adapter Plate, required to mount guard to surface 9" x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 4-3/4" x 6-7/8" x 1-1/2" deep, 4905-9916 Red 1-1/2" deep surface mounted boxes (121 mm x 175 mm x 38 mm) * UL listed by Space Age Electronics Inc. 2 S4906-0002-2 9/2004 Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with u to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F 0° to 50° C ; 10% to 93%, non-condensing at 100° F 38° C Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) ; two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Voltage 16 VDC 24 VDC 33 VDC Sound Type see Note 2 Steady Coded Steady Coded Steady Coded Horn Output Ratings @ 10 ft (3 m) Reverberant Chamber, 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA UL 464 Test Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions with lens 5-1/8" H x 5" W x 2-3/4" D 130 mm x 127 mm x 70 mm Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Mount Strobe Setting (see Note 3 below) 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC 70 mA 101 mA 184 mA 243 mA at other voltages 24 VDC 60 mA 84 mA 143 mA 185 mA Housing Dimensions with lens 4-3/4 L" x 6-7/8" W x 2-5/8" D 121 mm x 175 mm x 67 mm Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Mount Strobe Setting (see Note 3 below) 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC 81 mA 119 mA 216 mA 283 mA at other voltages 24 VDC 70 mA 97 mA 167 mA 217 mA NOTES: 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. 3. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Mountinq Mounting is compatible with single gang, double gang, and I _ i IMPORTANT! WALL MOUNT 4" (102 mm) square boxes, INSTALLATION HEIGHT REFERFNSF 1-1/2" (38 mm) deep, by others Bottom of lens is either even - - C with, or slightly Electrical 0 o o u above bottom box outline Wiring access hole O J of compatible tt / boxes Wiring terminals for tt SmartSync operation - ~ I "i - Mounting Holes: NFPA 72 requires 80" (2.03 m) 4" square (4) Single gang (2) that the entire lens minimum be not less than - 1 ~ Double gang (3) 80" and not greater than 96" above the finished floor ---0 Transparent housing and lens assembly Intensity selection 110 .75 plug, accessible only 15 from rear of housing; G , factory setting is 15 cd i Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0002-2 9/2004 Ceiling reference, 4" (102 mm) square box, Optional 4905-9928 Adapter Plate, surface mounted box 1-1/2" (38 mm) minimum depth required for surface mounted electrical box Four mounting clamps included, two each side _ C - - _ j J 1C .1 i_. t.. L~ L. l 1 i n0 ill li I ° Ceiling reference, o flush mounted box Optional 4905-9915/-9916 Adapter, recommended for surface mounted box Wiring terminals are Optional 4905-9927 Red Wire Guard i located behind the housing End View Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd Surface Mounting Reference 0 2975-9145 Box with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and O box shown for reference 4" (102 mm) square 0 box profile, 1-1/2" (38 mm) deep (l Optional O 4905-9961 Wire Guard nn nn AN 4905-9931 Adapter Plate Optional Surface Mount Adapte- Skirt, O 4905-9961 Optional Wire Guard 1-1/2" deep: 4905-9937, Red; (shown here for reference only, 4905-9940, White (conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco, Simplex, the Simplex logo, IDNet, TrueAlert, and SmartSync are trademarks of Tyco International AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). 93®Simplex Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4906-0002-2 9/2004 www.tycosafetyproducts-usa-wm.com 0 2004 Tyro Safety Products Westminster. All rights reserved. All specifications and other information shown were current as ofdoaonent revision date and are subject to change without notice. 00 COOPER Wheelock Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories 4 Description: Designed for life safety, performance and reliability, Cooper When used in conjunction with Wheelock PS-24-81VIC Power Wheelock's cost effective weatherpoof notification appliances Supplies or SM/DSM Sync Modules, the Wheelock weatherproof include: appliances can be synchronized to meet NFPA 72 synchronization Weatherproof Appliances Series requirements. The horn outputof horn strobescan be independently controlled on 2-wire circuits using the Wheelock patented sync Strobes RSSWP protocol. MTWP horn strobe models are 4-wire appliances; the Horn Strobes ASWP strobes can be synchronized while the audible can be connected Horns AH-24WP, AH-12WP to a coded fire alarm system or can be set to produce any of eight Multitone Horn Strobes MTWP selectable tones. Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 Features: All strobe models are UL dual listed - meeting both UL1638 Approvals include: UL Standards 1971, 1638, 464 and 1480 and UL1971 requirements. As dual listed appliances, these California State Fire Marshal (CSFM) and New York City weatherproof strobes, horn strobes and speaker strobes are listed (MEA), Factory Mutual (FM) and Chicago (BFP). See for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. agency approvals by model number on page two of this With an extended temperature range of -31°F to 150°F (-40°C document to 66°C), Wheelock weatherproof appliances meet or exceed UL Compliance with the following requirements: NFPA, UFC, outdoor test requirements for rain, humidity and corrosion resistance ANSI 117.1, OSHA Part 29, 1910.165, ADA while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 Weatherproof with extended temperature range of-40°F to strobe spacing tables (up to 185 candela forwall mounting and 177 150°F (-40°C to 66°C)` candela for ceiling mounting). • Dual Listed strobe models (UL 1638 and UL 1971) To enable weatherproof mounting, Cooper-Wheelock provides the Industry's highest strobe candela options industry's widest choice of mounting options for surface or unique • semi-flush installation. Models are available for surface mounting Synchronization capability using Series SM, DSM Synch to Wheelock weatherproof backboxes on walls or ceilings. The Modules (MTWP and MT-12/24 audible is non-sync) optional WP-KIT allowsthe weatherproof backbc es (IOB, WPBB or Models with field selectable tone, dBA and candela settings WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA and Wall or ceiling mounting options WFPA kits allow a customer to mount the weatherproof appl!,3nces Surface of semi-flush mounting to a recessed electrical box without the need for an external IN/OUT wiring termination accepting two #12-18 AWG wires weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these at each terminal mounting options and the required accessories. 'The series RSSWP, ASWP, MTWP and ET70WP have UL approval down to -40°F. The AH-24WP, MT-12/24 and the ET-1010 have been ULC tested and approved to -40'F, but not submitted to UL. The AH-12WP has UL/ULC approval to -31 °F APPRW E5946 151-92-E 7125-0785:131 (ASWP) S5391 7125-0785:146 (ET70WP) S2652 7125-0785:156 (MTWP) 7300-0785:154 (RSSWP) NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes,; • Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. • All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Wall Mount Ceiling Mount Wall or Ceiling Mount ?E: RSSWP MTWP RSSWP MTTwP MT AH Y VOW ASWP ET70WP - ASWP Er70WP ET-7010 Strobe Order Code Strobe Order Code Audible Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475C-FR Red 4338 AH-24WP-R Red 7416 RSSWP-2475W-FW White 3034 RSSWP-2475C-FW White 4446 AH-12WP-R Red 7415 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCCH-FR Red 5167 RSSWP-24MCWH-FW White 5165 RSSWP-24MCCH-FWWhite 5187 Horn Audible Strobe Audible Strobe MT-12/24-R Red 5023 ASWP-2475W-FR Red 9012 ASWP-2475C-FR Red 4251 Speaker ASWP-24MCHW-FR Red 5137 ASWP-2475C-FW White 4502 ET-1010-R Red 3135 ASWP-24MCWH-FW White 5140 ASWP-24MCCH-FR Red 5149 ET-1010-W White 3137 Multi tone Strobe ASWP-24MCCH-FW White 5157 MTWP-2475W-FR Red 8420 Multi-tone Strobe UL Max. Current AH MTWP-2475W-FW White 3112 MTWP-2475C-FR Red 4457 24 VDC JVDC MTWP-24MCWH-FR Red 5132 MTWP-2475C-FW White 4478 High (99) dBA 0.080 MTWP-24MCWH-FW White 5134 MTWP-24MCCH-FR Red 5102 ed (95) dBA 0.043 Speaker Strobe MTWP-24MCCH-FW White 5122 Low (90) dBA 0.021 ET70WP-2475WFR Red 9077 Speaker Strobe ET70WP-2475W--FW White 3179 ET70WP-2475C-FR Red 4452 UL Reverberant dBA @ 10 Feet ET70WP-24185W-FR Red 4885 ET70WP-2475C-FW White 4454 Wafts 1/8 1/4 1/2 1 2 4 8 ET70WP-24185WFW White 4891 ET70WP-24177C-FR Red 4845 ET70WP-24177C-FW White 4859 ET-1010 77 80 83 86 87 92 94 ET70WP 78 81 84 87 90 93 95 Candela Ratings UL 1638 UL 1638 RSS, ET70WP and ASWP Series UL 1971 ~ 77*F U -4038 MTWP UL Max Current Strobe Only) High Med Low Model Number Agency Approvals 2475 30*` 180 75 0.138 0.168 0.155 0.150 Strobe UL MEA CSFM FM BFP 135 135 56 0.300 0.355 0.340 0.335 MCWH RSSWP-2475 X X X X 185 185 77 0.420 0.480 0.465 0.460 RSSWP-24MCWH X 115 115 47 0.300 0.355 0.340 0.335 RSSWP-24MCCH X MCCH Audible Strobe _ 177 177 E773 0.420 0.480 0.465 0.460 ASWP-2475 X X X X X 24185 185 185 0.420 **Wall mount rating only ASWP-MCWH X 24177 177 177 0.420 ASWP-MCCH X ' Multitone Strobe MTWP-2475 X X X X ' LBell MTWPIMT MT MTWP-MCWH X ! ' 24 VDC 12 VDC MTWP-MCCH X ' HI STD HI STD Horns/Audibles 0.108 0.044 0.177 0.034 AH-24WP t X X X X - 0.053 0.024 0.095 0.020 AH-12WP X X X X 0.104 0.038 0.142 0.034 MT-12/24 1X X X X X 0.091 0.035 0.142 0.034 Speaker Strobe 1 Code 3 Tone 0.075 0.035 0.105 0.021 ET70WP-2475 X X X ' Slow Whoop 0.098 0.037 0.142 0.035 ET70WP-185 X Siren 0.104 0.036 0.152 0.030 ET70WP-177 X Hi/Lo 0.057 0.025 0.114 0.026 *Pending Mounting Accessories WFP WFPA IOB WPSBB WPBB WBB Gasket Kit Order Code WP-KIT 4486 Mounting Options: Flush Plates Backboxes, Plates, Gasket Kits WFPA-R Red 4698 Surface Mount Flush WFPA-W White 4701 Exposed Conduit Concealed Conduit Mount WFP-R Red 4696 WFP-W White 4697 RSSWP Strobes WPSBB WPSBB + WP-KIT WFP Backboxes ET70WP Speaker Strobes IOB IOB + WP-KIT WFP IOB-R Red 5046 ASWP Horn Strobes WPBB WPBB+ WP-KIT WFPA IOB-W White 5047 WPSBB-R Red 9751 AHWP Horns WBB WFP WPSBB-W White 3033 ET-1010 Speakers WBB WFP WPBB-R Red 9014 WPBB-W White 4692 MTWP Multitone Horn Strobes IOB IOB + WP-KIT WFP WBB-R Red 2959 Multitone Horn IOB IOB+Wp-KIT WFP WBB-W White 2960 - SERIES MTWP APPLIANCES SYNCHRONIZED STROBE Wiring Diagrams OPERATION WITH CODED FACP MTWP m 0 e Strobe SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE Modu Circuit le IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. NAC °r PS12/24- o Audible Power Circuit FROM TO NEXT FACP Supply RECEDING + + APPLIANCE PLIANCE _ RED - OR EOLR NAC #2 - Fi R FACP BLACK Note: Strobe circuit requires constant voltage. SERIES RSSWP/ASWPAPPLIANCES SYNCHRONIZED W/ + - 0 + - DSM MODULE SINGLE CLASS "A" NAC CIRCUIT STROBE AUDIBLE DSM STROBE NAC SYNC + SERIES RSSWP, ASWP, AHWP, MTWP AND MT-12/24 APPLIANCES CIRCUIT OUT +ouT I 0 + IN I a RSS FROM TO NEXT PRECEDING + + APPLIANCE MINUS I APPLIANCE OR OR EOLR I{ACP +_AUnISL FACP MINUS 2 ,IN 2 RSS A- RSS ROBE + - NAC + OUT 2 CIRCUIT RETURN Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. ARCHITECTS AND ENGINEERS SPECIFICATIONS General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under U L Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of -40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous outputor a temporal code-3 output that can be synchronized. T? Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET70WP. They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS-24-8MC Power Supply with built-in, patented sync protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock IOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. 1rII~iYrd1 273 Bra nchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732) 222-2588 3 YEAR WARRANTY www.cooperwheelock.com Made in USA S9004 WP 10/06