Loading...
07201264 Permit File F k zV~ ¢ CITY OF DUBLIN ao m AUG 2 $ 2Q07. ivision of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 ' 'j Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 ' WTFD: (614) 652-3920 . FIRE PROTECTION PERMIT APPLICATION Office Application Date Bldg. App. # ~rVJUI JL41 Fire Protection App. # X PROJECT INFORMATION Project Address ~43~5 L~ubl~g-G.rowyil4R.e~ N WoN Project Name JvcA0 "-s16.o 6 06" Owner/Tenant Contact Name 43&7Telephone VW-s t APPLICANT INFORMATION Fire Protection Contractor S i r1 t e ximAlt1l Address 404- S/,.'1M'TOCK Cr. Srt S. Telephone (o /:y - 602- 2mo State Certificate Number 53 25'/01f1 Dublin Registration Number 07-1153 Installer Name State Certificate Number SCOPE OF WORK (Mark One) New Replace Repair Alteration FIRE DETECTION AND ALARM SYSTEM (Number of Each) Detectors Strobes Horns Fire Alarm Boxes Other SUPPRESSION SYSTEM (Number of Each) Standpipes On Site Water Piping Sprinkler Heads Limited Area Other FEES FIRE DETECTION OR SUPPRESSION PERMIT PROCESSING FEE $60.00 LOW VOLTAGE PERMIT (DETECTION ONLY) $30.00 Minimum fee plus $20.00 each 1,000 sq ft or fraction thereof over 1,000 sq ft OUTSIDE PLAN REVIEW SERVICES (EXAMINER'S FEE AS CHARGED) ac. ce STATE SURCHARGE (3%) -5-. Li 0 TOTAL FEE DUE 19 5 L4 O This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. This permit conveys no right to open any street, alley or sidewalk or an part ther f, nor to make any connection to a water main. Signature of Licensed Contractor DATE 0 Print Name lc~iA~ 14 DATE Zy ~7 FOR OFFICIAL USE ONLY Review Comments: The fie ekrrn S'i /74 ~ii~ s «i G~rAwih S /hP LVas~%~ n e-17 owns i" Fiie r e 9 rov9 s~ife ~~i ~i~fion n v~b~?" on Pr~nif aroo/rc9fio~ ~~Q~> Fire Department: Date: 90/0 z Plans Examiner: ~rn1L Date: -7 Issued by CBO: Date: CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00201264 Date 9/19/07 Property Address . . . . . . 4365 W DUBLIN-GRANVILLE RD Parcel Number: 273-008269 Alternate Address: SHOPPES AT RIVER RIDGE Tenant nbr, name . . . . . . ANDACIOUS/DETECTION Application type description FIRE PROTECTION Property owner . . . . . . THE SHOPPES AT RIVER RIDGE Contractor . . . . . . . . . SIMPLEX GRINNELL Permit . . . . . . FIRE DETECTION PERMIT Additional desc . . Permit Fee . . . . 60.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 60.00 Special Notes and Comments CONTACT WASHINGTON TOWNSHIP FIRE PREVENTION FOR INSPECTIONS AT 766-0857 Other Fees . . . . . . . . . OUTSIDE PLAN REVIEW 120.00 SURCHARGE FEE - BLDG 3.60 SURCHARGE FEE - FIRE 1.80 Fee summary Charged Paid Credited Due Permit Fee Total 60.00 .00 .00 60.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 125.40 .00 .00 125.40 Grand Total 185.40 .00 .00 185.40 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Application #07-201264 September 18, 2007 CONDITIONAL PLAN APPROVAL FIRE ALARM/DETECTION SYSTEM THIS IS NOT A BUILDING PERMIT. IT IS A RECORD OF OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT. Re: Audacious - Tenant Build Out Applicant: Simplex Grinnell Fire Alarm/Detection System (614) 602-2000 4365 West Dublin-Granville Road Fire Protection Permit No: 07-201264 The Fire Alarm/Detection Drawings dated 2/26/07, as submitted with the Fire Protection Permit Application, for the captioned project, has been reviewed for compliance with the provisions of the 2007 Ohio Building Code (OBC). The review was based upon the following criteria: Use Group: Existing, No Change Occupancy: n/a Area: n/a Const. Type: II B, Noncombustible / Unprotected Notes: Addition of new fire alarm/detection system for this new Tenant Build-Out space. The Fire Alarm/Detection Drawings have been signed and certified by Robert G. Sines III, Ohio Certification #F- 032. The fire protection contractor is J&J Clement Electric Co., Ohio State Certification Number 53-25-1571, the installer has NOT been identified, to comply with the requirements of OBC Section 105.3 and have been reviewed, therefore, in accord with OBC section 105.3.1.4. This CONDITIONAL PLAN APPROVAL for the fire protective signaling system only, is issued by the City of Dublin, Division of Building Standards, in accordance with Section 106.3.2 OBC. The following item(s) shall be brought into full conformance with the OBC prior to the issuance of any conditional or final plan approval: 1. OBC 105.3.1.4.(3) Certified Installer Indicate thereon the individual installing the fire protection systems who shall be certified by the Fire Marshal pursuant to Section 3737.65 of the Revised Code. In the event that the installer is not known at the time of plan approval, partial plan approval shall be granted subject to subsequent submission by addendum of the name of the qualified installer prior to installation of any part of the fire protection systems. The individual responsible for `installing' the fire alarm/detection system was not identified on the Application, or on the drawings provided The Fire Protection Permit Application indicates that the Installer is "to be determined. " Please provide the name and certification number of this individual, in City of Dublin FIRE PROTECTION PLAN REVIEW 07-201264 Audacious - Tenant Build Out September 18, 2007 07-201264 Page 2 accordance with the provisions of this code requirement. For the information of the Applicant the following item(s) are required for code compliance, but are not necessarily covered in detail in the construction documents This list is a reminder to the design professional and contractors of issues which are to be satisfactorily dealt with in the field: 2. The certificate of approval of fire protection plans shall be posted in a conspicuous location outside of the building or in the front part of the premises on which is, or will be, located the approved building or equipment. The owner and the contractor shall, so far as possible, preserve and keep said certificate until the completion of the work to which the approved construction documents relate; Section 105.7.2 OBC. 3. The proposed construction shall conform to the requirements of Chapter 11 OBC and the "Americans with Disabilities Act Accessibility Guidelines" (ADAAG). 4. Fire Alarm System cable and wiring located in noncombustible plenums shall meet with the requirements of Section 907 OBC and Article 760, NFPA 70. 5. Provide a record of completion for each completed fire alarm system in accordance with Section 907.17 and NFPA 72 Completion Documents. 6. Upon completion of the fire protective signaling system, all alarm-initiating devices and circuits, alarm- indicating appliances and circuits, supervisory-signal initiating devices and circuits, signaling line circuits, and primary and secondary power supplies shall be subjected to a 100 percent acceptance test in accordance with NFPA 72A and 72E listed in Chapter 35; Section 907.16 OBC. 7. OBC 907 Acceptance testing: When the installation of the detectors is complete, each detector and all interconnecting wiring for multiple-station detectors shall be subject to a 100-percent acceptance test in accordance with the household fire warning equipment provisions of NFPA 72 listed in Chapter 35. 8. No electrical work (conduits, cables or other electrical apparatus) may be covered or concealed without visual inspection and approval by the electrical field inspector as per OBC 109. 9. The existing electrical conductors, if removed, abandoned, or altered, shall be accomplished to the electrical field inspectors approval pursuant to the requirements of Section 109 OBC. Electrical work found not to meet the code's standards shall be corrected to the electrical field inspector's approval. 10. All electrical work will comply with the requirements of Article 27 OBC and the National Electric Code NFPA 70, OBC approved edition and is subject to the approval of the electrical inspector, in accordance with Section 109 of the OBC. TO REQUEST AN APPEAL HEARING, YOU MUST send a written request, listing the items to be appealed and the relief sought and on copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin, Ohio 5800 Shier Rings Road Dublin, Ohio 43017-1236 City of Dublin FIRE PROTECTION PLAN REVIEW 07-201264 Audacious - Tenant Build Out September 18, 2007 07-201264 Page 3 THE SIGNING OF THIS DOCUMENT IS AN AGREEMENT THAT YOU WILL COMPLY WITH ALL ITEMS LISTED HEREIN. THE COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF ALL ITEMS LISTED HEREIN. Reviewed and signed, Michael A. Boryca, Architect/Plans Ex er Jeffr S. ler, hie Building Official (614) 488-4009 City of Dub ' hio Signature - Architect, Engineer, Contractor Date or Owner Print Name and Title as Signed c: Washington Township Fire Department MAB:Iwb City of Dublin FIRE PROTECTION PLAN REVIEW 07-201264 architecture! memorandum invoice #07-201264 -1 OHIO INCORPORATED 454 East Main Street Suite 236 Columbus, Ohio 43215-5380 614.488.4009 fax.488.4005 September 18, 2007 City of Dublin Contract No. PS 01-21-13 Employer Identification No. 31-1413248 City of Dublin Division of Building Standards 5800 Shier-Rings Road Dublin, Ohio 43016 Attention: Mr. Jeffrey S. Tyler, Chief Building Official Plan Review Services for: Audacious - Tenant Build Out - Fire Alarm/Detection System 4365 West Dublin-Granville Road CONDITIONAL PLAN APPROVAL Permit No. 07-201264 Labor Cost: Total Number of Hours to be Charged @ $60.00/Hour: 2.0 • Review Time: 1.0 • Administration Time: 1.0 TOTAL BILLING THIS INVOICE $120.00 This memorandum invoice is being sent as reference for you to prepare the necessary fees for the applicant to pay. The time spent on this review will be submitted for payment at the end of the month with our usual invoicing. Should you have any questions or comments concerning this review, please don't hesitate to contact me. Thank you for the opportunity to be of service. Cordially, architecture! Michael A. Boryca, Architect Plans Examiner 4P001794 RECEIVED CITY OF DUBLIN AUG 2 2'10ivi1DE D - ~sion of Building Standards • 5800 Shier-Rings Road • 416, '4 UiLDING DIVSION Phone: (614) 410-4670 • Inspection Line: (614) 10-4680 CITY F MJ6LIN WTFD: (614) 652-3920 AUG 31 2007 FIRE PROTECTION PERMIT APPLICATI6N-- Application Date 7-4 o Bldg. App. # ~cAo, 4 ~ l Fire Protection App. # a~4' PROJECT INFORMATION Project Address 4& *57 ~ublj~-~.rowril?kR.d. Dw, N Project Name *94!-S o s +4' Owner/Tenant Contact Name I0007Telephone vt APPLICANT INFORMATION Fire Protection Contractor S ? v4p1w 6alm4fell ~ L. P. Address 409' S&qMReCK Cr. .SrE S. Telephone 6/y - 60.2- 2aeo State Certificate Number St 2s 10w Dublin Registration Number 07-1153 Installer Name 1 be r-~e~ico~+~%~t•( State Certificate Number SCOPE OF WORK (Mark One) New Replace Repair Alteration FIRE DETECTION A D ALARM SYSTEM (Number of Each) Detectors Strobes Horns Fire Alarm Boxes Other SUPPRESSION SYSTEM (Number of Each) Standpipes On Site Water Piping Sprinkler Heads Limited Area Other FEES FIRE DETECTION OR SUPPRESSION PERMIT PROCESSING FEE $60.00 LOW VOLTAGE PERMIT (DETECTION ONLY) $30.00 Minimum fee plus $20.00 each 1,000 sq ft or fraction thereof over 1,000 sq ft OUTSIDE PLAN REVIEW SERVICES (EXAMINER'S FEE AS CHARGED) STATE SURCHARGE (3%) TOTAL FEE DUE This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. This permit conveys no right to open any street, alley or sidewalk or an part ther f, nor to make any connection to a water main. Signature of Licensed Contractor DATE 2'`J Print Name lc`IAc A/L DATE 7 FOR OFFICIAL USE ONLY Review. Comments: Fire Department: Date: Plans Examiner: 61-m CAS- Date: 9'17' ~7 Issued by CBO: Date: S.Simplex Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; IDNetTM or MAPNET II® Communicating Devices MEA (NYC) Acceptance* Addressable Manual Stations Individually addressable manual fire alarm _ stations with: • Power and data supplied via IDNet or MAPNET II ¦ addressable communications using a single wire pair** • Operation that complies with ADA requirements • Pull lever that protrudes when alarmed - -J • Break-rod supplied (use is optional) • Models are available with single or double action (breakglass or push) operation 4099-9001 Addressable Manual Station • UL listed to Standard 38 (front and side view) Compatible with the following Simplex® control panels: I I • Model Series 4008, 4010, 4100U, 4020, 4100, and 4120 fire alarm control panels equipped with either IDNet or MAPNET II communications Ire- I - Op KEY ERATED • Model Series 2120 Communicating Device ONLY Transponders (CDTs) equipped with MAPNET Il communications Compact construction: 4099-9002 4099-9003 With 2099-9828 • Electronics module enclosure minimizes dust Breakglass Push Institutional infiltration Cover kit Allows mounting in standard electrical boxes • Screw terminals for wiring connections Activation of the Simplex 4099-9001 single manual station requires a firm downward pull to activate the Tamper resistant reset key lock (keyed same as alarm switch. Completing the action breaks an internal Simplex fire alarm cabinets) plastic break-rod (visible below the pull lever, use is Multiple mounting options: optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull • Surface or semi-flush with standard boxes or requirements needed for easy activation. The pull lever matching Simplex boxes latches into the alarm position and remains extended out • Flush mount adapter kit of the housing to provide a visible indication. • Adapters are available for retrofitting to commonly Double Action Stations (Breakglass) require the available existing boxes operator to strike the front mounted hammer to break the _ glass and expose the recessed pull lever. The pull lever ,'hen operates as a single action station. The Simplex model 4099-9001 addressable station Double Action Stations (Push Type) require that a combines the familiar Simplex manual station housing spring load: d interference plate (marked PUSH) be with a compact communication module that is easily pushed back to access the pull lever of the single action installed to satisfy demanding applications. Its integral station. individual addressable module (IAM) constantly monitors Station reset requires the use of a key to reset the status and communicates changes to the connected control manual station lever and deactivate the alarm switch. (If panel via IDNet or MAPNET 11 communications wiring. the break-rod is used, it must be replaced.) Refer to page 2 for specific model listings. This product has been approved by the Station testing is performed by physical activation of California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health the pull lever. Electrical testing can be also performed by and Safety Code. See CSFM Listing 7150-0026:224 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, unlocking the station housing to activate the alarm switch. and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product communications designs are protected by U.S. supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are IDNet patent anNo. d nd 4 MAPNEAPNET 25; II addressable and communmmun601. the property of Tyco Safety Products Westminster. S4099-0001-7 5/2006 MOM M . Addressable Manual Stations, Red Housing with White Letters and White Pull Lever Model Description Housing Pull Lever Listings 4099-9001 Single action, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM, MEA 4099-9001CB Single action, Bilingual English and French FEU FIRE TIREZ PULL ULC, FM 4099-9001 CF Single action, French ALARME FEU ABAISSEZ 4099-9002 Double action, Breakglass operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM, MEA 4099-9003 Double action, Push operation, English Accessories Model Description 2975-9178 Surface mount steel box, red - Refer to page 3 for dimensions 2975-9022 Cast aluminum surface mount box, red _2099-9813 Semi-flush trim plate for double gang switch box, red Typically for retrofit, refer to page 4 2099-9814 Surface trim plate for Wiremold box V5744-2, red 2099-9819 Flush mount adapter kit, black Refer to page 4 for details 2099-9820 Flush mount adapter kit, beige 2099-9803 Replacement breakglass 2099-9804 Replacement break-rod 2099-9828 Institutional cover kit for field installation on 4099-9001 • Power and Communications IDNet or MAPNET II communications, 1 address per station Address Means Dipswitch, 8 position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire UL Listed Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan® polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5" H x 3-3/4" W x 1" D (127 mm x 95 mm x 25 mm) Single Gang Box Mount 4" Square Box Mount Single gang box, 2-1/2" deep 4" (102 mm) square box, 2-1/8" (54 mm) minimum (64 mm), RACO #500 or equal depth, RACO #231 or equal (supplied by others) (supplied by others) 0 o Mount flush or with o ri 1/16" (2 mm) maximum extension 0 01 r DO NOT RECESS 4" Square box J / with cover plate o _o 17jy L I station FIRE ® ALARM side view Single gang cover plate, 3/4" (19 mm) extension, RACO #773 PULL DOWN 11 or equal (supplied by others) Single gang box outline Wall surface Semi-Flush Mount Side View f35i»plex' 2 S4099-0001-7 5/2006 • 2975-9178 Box 2975-9022 Cast Box Preferred Mounting. For 5-3/16" H x 4" W x 2-3/16" D 5" H x 3-7/8" W x 2-3/16" D surface mounting these (132 mm x 102 mm x 56 mm) (127 mm x 98 mm x 56 mm) g of (ordered separately) (ordered separately) addressable manual stations, the preferred electrical boxes are shown in the illustration to the right. 0 0 o 0 Additional Mounting Knockouts located Reference. Refer to page 4 for top and bottom Wiremold box mounting compatibility. FIRE ®ALARM 0 0 PULL DOWN Access for 3/4" threaded 5„ conduit located top and bottom (127 mm) i Simplex 1" (25.4 mm) 4. 3-3/4" (95 mm)--? 4099 Series Addressable Manual Station • • • Refer to NFPA 72, the National Fire Alarm Code, and all applicable local 1-1/4" codes for complete requirements for (32 mm) Simplex 2975-9178 box manual stations. The following Field wiring (shown for reference) (shown for reference) summarizes the basic requirements. 1. Stations shall be located in the normal path of exit and distributed in the protected area such that they Address setting under are unobstructed and readily resealable label (accessible accessible. with cover open) 2. Mounting shall be with the 2-5/8" (67 mm) operable part not less than 3-1/2 ft (1.1 m) and not more than 4-1/2 ft Station cover (1.37 m) above floor level. hinges open for installation access 3. At least one station shall be provided on each floor. Additional Switch wiring stations shall be provided to obtain (prewired) a travel distance not more than 200 ft (61 m) to the nearest station / from any point in the building. 4. When manual station coverage appears limited in any way, additional stations should be installed. 3 S4099-0001-7 5/2006 Nil For retrofit and new installations, additional 0 0 compatible mounting boxes Wiremold ;.o receptacle box and the required adapter plates 2099-9814 Surface trim model V5744-2 are shown in the illustration to for Wiremold box (supplied by the right. 5-1/8" H x 5" W others) (130 mm x 127 mm) 0 0 0 o Two gang switch box, each 3" H x 2" W x 2-3/4" D (76 mm x 51 mm x 70 mm) - (supplied by others) 4099-9001 1 D Net ( o addressable station o o 7'17- ~ I - 2099-9813 Semi-flush trim for 2 gang o E=) o switch box, 6" H x 4-1/2" W (152 mm x 114 mm) MR-FIMM. -.1fliviRITFROMM Marna 1111-1111C.111-M-11 Flush mount adapter kit 2099-9819, Black 2099-9820, Beige Box 77/8" st be recessed into wall 1to (25.4 mm to 29 mm) 203 mm ( ) y n Hole cutout must be a r minimum of 6" H by 5" W ( mm) m) (152m m by 127 mm) o r r~ / 4-11/16" (119 mm) square box, 2-1/8" (54 mm) minimum Wall depth (by others) 4-3/4" (121 mm) ? surface 6-3/4"(171 mm) Front View Side View 7yco, Simplex, the Simplex logo, MAPNIil11, and IDNet are trademarks of 1) c-o International Senvees AG or its affiliates in the U.S. and or otter countries. NF7 A 72 and National Fire Alarnt Code are registered trademarks e?/ the National hire Protection Association (NMIA). Lexan is a trademark of the General Electric Co. Wiremold is a trademark of the Wiremold Congxmy. .G.Simplex Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4099-0001-7 5/2006 www.tycosafetyproducts-usa-wm.com e, 2006 Two SaJery PrahtcIs Weslnunater. All rights reserved. All.speciflcahon.s and other infhrntation shown were current as ol'doctmmm revision date and are subject to change a ithow notice. £;,Simplex TrueA/erto Multi-Candela Notification Appliances UL, ULC Listed; FM Visible Notification Appliances with Horn and Synchronized and CSFMApproved* Flash; Non-Addressable, SmartSynCTM Operation Compatible ® , Audible/visible (A/V) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount • Operation is compatible with ADA requirements (refer to important installation information on page 3) ? • Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens. Operates over a two-wire SmartSync circuit to provide: • Horns that are controlled separately from strobes on the same two-wire circuit • "On-until-silenced" and "on-until-reset" operation on - the same two-wire pair • Horn control that can be selected to be temporal coded, march time coded, or on continuously • Strobe appliances on the same circuit operating at a synchronized I Hz flash rate • Class 13 (Style Y) operation requires connection to a compatible SmartSync NAC or to SmartSync Control Wall and Ceiling Mount ANs Module (SCM) 4905-9938 - • Class A (Style Z) operation when connected to the 4905-9938 SCM or with 41000 series fire alarm control Multi-Candela TrueAlert ANS with horn and panel NACs synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are Wall mount A/Vs features: both impact and vandal resistant and provide a convenient • Wiring terminals are accessible from the front of the strobe intensity selection. Since each model can be housing providing easy access for installation, selected for strobe intensity output, on-site model inspection, and testing inventory is minimized and changes encountered during • Covers are available separately to convert housing color construction can be easily accommodated. Optional adapters and wire guards: Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or • Wall mount AN adapters are available to cover surface 4" square standard electrical box. The cover can be mounted electrical boxes and to adapt to Simplex`' quickly removed (a tool is required) and covers are 2975-9145 boxes available separately for color conversion. • UL listed red wire guards are available for wall or ceiling mount A/Vs Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is determined by model number. Visible notification appliance (strobe): Mm. WRIMaLgrEmam • 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured During installation, a selection plug at the back of the behind strobe housing housing detennines the desired strobe intensity. An • UL listed to Standard 1971 attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the • Regulated circuit design ensures consistent flash Output side of the strobe lens. and provides controlled inrush current " This product has been approved by the California State Fire Marshal (CSFM) pursuant to Audible notification appliance (horn): Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:317 for allowable values and/or conditions concerning material presented in this • Low current, 24 VDC electronic horn with harmonically document. It is subject to re-examination, revision, and possible cancellation. This product rich output sound suitable for either coded or Stead was not approved by MEA (NYC) as of document revision date. Refer to page 2 for listing rich y status of wire guards. Additional listings may be applicable; contact your local Simplex operation product supplier for the latest status. Listings and approvals under Simplex Time Recorder UL listed to Standard 464 Co. are the property of Tyco Safety Products Westminster. " Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5,559,492 and SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789. S4906-0002-2 9/2004 Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy, location, local codes, and proper applications provide the ability to activate both the horn and strobe on of: the National Fire Alarm Code (NFPA 72), ANSI the same NAC and then allow the horn to be silenced A117. 1; the appropriate model building code: BOCA, while the strobe remains flashing. The horn operates as ICBO, or SBCCI; and the application guidelines of the "on-until-silenced" while the strobe operation is Americans with Disabilities Act (ADA). "on-until-reset." ©I . . Multiple Strobes. When multiple strobes and their • 41000 and 4010 Fire Alarm Control Panels (refer to reflections can be seen from one location, synchronized data sheet S4010-0001 for details; refer to data sheet flashes reduce the probability of photo-sensitive reactions S4100-0031 for basic 4100U information) as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender (refer to data sheet random flashing. The multi-candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation SmartSync Control Module (SCM) 4905-9938 (refer to NAC. data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Multi-Candela A/Vs Model Mounting Housing Color "FIRE" Lettering Description 4906-9127 Wall Red White 4906-9129 White Red Horn with Multi-Candela Strobe; strobe intensity selectable as: 4906-9128 Red White 15, 30, 75, or 110 candela; operates with SmartSync two-wire 4906-9130 Ceiling White Red control Wall Mount AN Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep 5-3/8" H x 5-1/4" W x 1-5/8" D surface mounted boxes (136 mm x 133 mm x 41 mm) 4905-9940 White depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount ANs Model Description Dimensions 4905-9994 Red cover with white "FIRE" lettering 5-1/8" H x 5" W x 1-1/2" D 4905-9995 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimensions 4905-9961* Wall mount red wire guard with mounting plate, compatible with semi-flush 6-1/16" H x 6-1/16" W x 3-1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2" x 6-1/8" x 3" (216 mm x 156 mm x 76 mm) 4905-9928* Ceiling Red Adapter Plate, required to mount guard to surface 9" x T' Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 4-3/4" x 6-7/8" x 1-1/2" deep, 4905-9916 Red 1-1/2" deep surface mounted boxes (121 mm x 175 mm x 38 mm) * UL listed by Space Age Electronics Inc. 2 S4906-0002-2 9/2004 • Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) ; two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Voltage 16 VDC 24 VDC 33 VDC Horn Output Ratings Sound Type (see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft (3 m) Reverberant Chamber, 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA UL 464 Test Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5-1/8" H x 5" W x 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Strobe Setting (see Note 3 below) 75 mA 116 mA 221 mA 285 mA Mount Reference RMS Currents 18 VDC 70 mA 101 mA 184 mA 243 mA at other voltages 24 VDC 60 mA 84 mA 143 mA 185 mA Housing Dimensions (with lens) 4-3/4 L" x 6-7/8" W x 2-5/8" D (121 mm x 175 mm x 67 mm) Ceiling Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Mount Strobe Setting (see Note 3 below) 86 mA 132 mA 250 mA 320 mA j Reference RMS Currents 18 VDC 81 mA 119 mA 216 mA 283 mA at other voltages 24 VDC 70 mA 97 mA 167 mA 217 mA NOTES: 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. 3. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) • • . • 0 0 Mounting is compatible with single gang, double gang, and &rr 1 ° r 1 IMPORTANT! WALL MOUNT 4" (102 mm) square boxes, INSTALLATION HEIGHT REFERENCE 1-1/2" (38 mm) deep, by others o 0 no Bottom of lens is either even with, or slightly Electrical © o o above bottom box outline Wiring access hole of compatible boxes Wi rtSync opera or o tt SmartSync operation F Mounting Holes: NFPA 72 requires 80" (2.03 m) 44 Si square g ( that the entire lens minimum Single gang (z) be not less than Double gang (3) 80" and not greater than 96" above the finished floor Transparent housin g and lens assembly Intensity selection plug, accessible only from rear of housing; is n factory setting is 15 cd Removable] cover Strobe intensity (tool required) viewing slot 3 S4906-0002-2 9/2004 Eftm-trar-Wil IMF M., MR0 MR Ceiling reference, 4" (102 mm) square box, Optional 4905-9928 Adapter Plate, mum depth required for surface mounted electrical box\ Four mounting clamps included, two each side 1 tsurface ted box 1-112" Ceili(38ng mm) mini reference, c:::n rr flush mount ed box Optional 4905-9915/-9916 Adapter, - - recommended for surface mounted box Optional 4905-9927 Wiring terminals are Red Wire Guard located behind the housing End View ~ I Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd 77111 161-WX Surface Mounting Reference _ 2975-9145 Box with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and O box shown for reference 4" (102 mm) square box profile, 1-1/2" (38 mm) deep Optional O O 4905-9961 Wire Guard nn AN o W 4905-9931 Adapter Plate Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-112" deep: 4905-9937, Red; (shown here for reference only, 4905-9940, White (conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco, Simplex, the Simpler logo, lDNet, TrueAlert, and Smart Sync are trademurks a/'Tvco ]niernational AC or its g1tiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code ore registered trademarks of the National Fire Protection Association (NFPA). 93®Simplex Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4906-0002-2 9/2004 www.tycosafetyproducts-usa-wm.com K)2004 Tyco Safety Porthicts Westminster. All rights reserved. All specifications and utter information shown were cu rent as of tkmi rent revision date and are subject to chunge without notice. O Simplex TrueA/ert® Multi-Candela Notification Appliances UL, ULC Listed, FM Visible Notification Appliances with Synchronized Flash; and CSFM Approved* Non-Addressable, SmartSynCTM Operation Compatible - RIM M_ Visible only (V/O) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: • UL listed to Standard 1971 - • Intensity is selectable as 15, 30, 75, or 1 10 candela with, visible selection jumper secured behind strobe housing M • Operation is compatible with ADA requirements (refer to important installation information on page 3) • Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Wall Mount Strobes • Regulated circuit design ensures consistent flash output and provides controlled inrush Current I • Rugged, high impact, flame retardant thermoplastic - - housings are available in red or white with clear lens Strobes provide synchronized flash for use with: / - • 4010 Series and 4100U Series fire alarm control panels Ceiling Mount Strobes with NACs selected to provide strobe synchronization or SmartSync two-wire control** • • • 4009 IDNetTm NAC Extenders Multi-Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes. The enclosure designs are both impact and vandal • Separate SmartSync Control Modules (SCMs) that resistant and provide a convenient strobe intensity provide Class B or Class A output from conventional selection. Since each model can be selected for intensity NAC inputs output, on-site model inventory is minimized and changes encountered during construction can be easily Strobe housings provides flexible, easy, and accommodated. convenient semi-flush or surface wall mounting: Wall mount strobe housings are a one-piece assembly • Rear of housing does not extend into box (including lens) that mounts to a single or double gang, or • Wall mount strobes easily mount to single gang, double 4" square standard electrical box. The cover can be gang, or 4-inch square outlet box quickly removed (a tool is required) and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model • Wiring terminals are accessible from the front of the number. housing providing easy access for installation, inspection, and testing • • • • Covers are available separately to convert housing color During installation, a selection plug at the back of the Optional adapters and wire guards: housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow • Wall mount strobe adapters are available to cover background allows the selected intensity to be,seen at the surface mounted electrical boxes and to adapt to side of the strobe lens. Simplex' 2975-9145 boxes - • UL listed red wire guards are available for wall or ceiling mount strobes Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications This product has been approved by the California State Fire Marshal (CSFM) pursuant to of. the National Fire Alarm Code (NFPA 72), ANSI Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning material presented in A 117.1; the appropriate model building code: BOCA, this document. It is subject to re-examination, revision, and possible cancellation. This ICBO, or SBCCI; and the application guidelines of the product was not approved by (NYC) as of document revision date. Refer to page 2 for AtpCtjCanS with Disabilities Act listing status of wire guards. Additional listings may be applicable; contact your local (ADA)• Simplex product supplier for the latest status. Listings and approvals under Simplex Time " Two-wire strobe synchronization operation is protected by U.S. Patent No. 5,559,492; Recorder Co. are the property of Tyco Safety Products Westminster. SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789; strobe designs are also protected under U.S. Patent Nos. 5,886,620; 5,622,427; and 5,865,527. S4906-0001-1 8/2004 Multiple Strobes. When multiple strobes and their Class B SmartSync two-wire control is available reflections can be seen from one location, synchronized from: flashes reduce the probability of photo-sensitive reactions . 41000 and 4010 Fire Alarm Control Panels; 4010 as well as the annoyance and possible distraction of panels require operating software Revision 2.X or random flashing. These multi-candela strobes are higher (refer to data sheet S4010-0001 for details; refer synchronized over a two-wire circuit when connected to to data sheet 54 1 00-003 1 for basic 41000 information) compatible NACs, to compatible Synchronized Flash . 4009 IDNet NAC Extender, models 4009-9201 and Modules, or to SmartSync Control Modules. 4009-9301 (refer to data sheet S4009-0002) M. • SmartSync Control Module (SCM) 4905-9938, converts separate conventional horn and strobe NAC Some applications desire the audible notification inputs into a SmartSync NAC output; up to eight SCMs appliances to be capable of being silenced before the can be synchronized to each other alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the Class A SmartSync two-wire control is available alarm condition is reset (on-until-reset). SmartSync from 4100U NACs and from the 4905-9938 SCM. operation mode provides this function using a single Additional SmartSync compatible notification circuit (two-wire operation). appliances include separate horns and combination horn/strobe notification appliances. Multi-Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color "FIRE" Lettering Description 4906-9101 Red White 4906-9103 Wall White Red Multi-candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; 4906-9102 Ceiling Red White SmartSync two-wire control compatible 4906-9104 White Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) 5-3/8" H x 5-1/4" W x 1-5/8" D 4905-9940 White deep surface mounted boxes (136 mm x 133 mm x 41 mm) Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8" x 3-1/8" x 0.060" D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with 1-3/8" x 2-7/16" x 13/16" in/out 18 AWG (0.82 mm) wire leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905-9922 Class A requires 10 mA for power 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4-1/8" x 1-1/4" D 4" (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white "FIRE" lettering 5-1/8" H x 5" W x 1-1/2" D For Wall mount strobes 4905-9993 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) 4905-9961* Wall mount 6-1/16" H x 6-1/16" W x 3-1/8" D Red wire guard with mounting plate, compatible with (154 mm x 154 mm x 79 mm) 4905-9926* Ceiling mount semi-flush or surface mounted boxes 6-1/8" x 4-3/8" x 2-7/8" deep (156 mm x 111 mm x 73 mm) * UL listed by Space Age Electronics Inc. 2 S4906-0001-1 8/2004 Mr-r-T-TIT-MMITT, M, Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8" H x 5" W x 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RIMS Current Rating per 15 cd 30 cd 75 cd 110 cd Strobe Setting (see Note 2 below) 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents 18 VDC 55 mA 85 mA 169 mA 226 mA at other voltages 24 VDC 41 mA 63 mA 123 mA 164 mA Housing Dimensions (with lens) 4-3/4" L x 2-5/16" W x 2-5/8" D (121 mm x 75 mm x 67 mm) Ceiling Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Strobe Setting (see Note 2 below) 75 mA 125 mA 233 mA 316 mA Mount Reference RIMS Currents 18 VDC 64 mA 102 mA 199 mA 266 mA at other voltages 24 VDC 49 mA 76 mA 146 mA 195 mA NOTES: 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RIMS is root mean square and refers to the effective value of a varying current waveform.) 0 0 Mounting is compatible with \ o / \ r single gang, double gang, and 1 1 4" (102 mm) square boxes, o 0 1-1/2" (38 mm) deep, by others o o o IMPORTANT! WALL MOUNT 11 1 V-) INSTALLATION HEIGHT REFERENCE Bottom of lens is e ither even *;,THU11,E1M with, or slightly Electrical Wiring access hole above bottom box outline of compatible boxes Wiring terminals a Mounting Holes: 4'I square (4) NFPA 72 requires 80" (2.03 m) ~mdba ° ® Single gang (2) that the entire lens minimum Double gang (3) be not less than 80" and not greater than 96" above the Transparent housing finished floor and lens assembly Intensity selection plug, accessible only from rear of housing; 1e [NEI factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0001-1 8/2004 IM-MrM • Handy box, 1-1/2" ( 38 mm) deep Single gang box (Wiremold (RACO 650 or equal) or single gang V5744S) 2-1/4" (57 mm) box, 2-1/2" (64 mm) deep (RACO 519 deep, supplied by others or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) 4905-9910 Adapter Plate, required for / surface mount with handy box unless i/ using the 4905-9926 wire guard Ceiling mount strobe IF O LEE- Optional 4905-9926 wire guard U U with mounting plate Strobe Strobe intensity i t~ viewing slot Intensity selection plug, accessible only from rear of lens' housing; factory setting is 15 cd i Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt and Optional Wire Guard 1 56:9 Surface mount conduit and O box shown for reference 4" (102 mm) square m~*'•` box profile, 1-1/2" I, I (38 mm) deep Optional O O 4905-9961 Wire Guard L nn Strobe 7 4905-9931 Adapter Plate Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2" deep: 4905-9937, Red; (shown here for reference only, 4905-9940, White (conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco, Simplex, the Simpler logo, IDNet, TnteAlert, and SmartSvne are trademarks of Tyco International AG or its ggiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks ojthe National Fire Protection Association (NF'PA). U.Simplex Tyco Safety Products Westminster cts-usa-wm. om 1441-0001 • USA S4906-0001-1 8/2004 © 2004 Tyco Safety Prockicts Westminster. All rights reserved All specifications and other information shorn were current as of do( anent revision date and are subject to change without notice. Williams Shepherd Architects II~~ ~IJ~J~n nn 4254 Dublin, OHr4301d7 °IEU~I~n QI~ Lr iJ NL;~?I~~//~~11 IJ~ NCff11% Phone: (614) 761-0881 Vl~ FAX: (614) 761-0717 Date: 22 AUGUST 2007 Job No: RRO07-052 Attention: RAY HARPHAM Re: TO: CITY OF DUBLIN AUDACIOUS DIVISION OF BUILDING STANDARDS 4365 W. DUBLIN-GRANVILLE ROAD 5800 SHIER RINGS ROAD DUBLIN, OHIO 43017 DUBLIN, OHIO 43016 APPLICATION NUMBER: 07-201221 PH: 614-410-4670 WE ARE SENDING YOU: ® Attached ® Hand Delivered ? UPS NEXT DAY ? Pick-Up ? Fax ? Under separate cover via the following items: ? Prints ® Plans ? Reproducibles ? Computer Disk ? Storm Calculations ? Sealed Drawings ( Dated: ) ? Boring Reports ? Site Checks ? Specifications ? Other: COURIER COPIES DATE 8 08/21/2007 FIRE ALARM AND SIGNALING DRAWINGS 8 08/21/2007 EQIPMENT CUT SHEETS THESE ARE TRANSMITTED as checked below: ® For Your Use ? For Review and Comment ® As Requested ? Return with Corrections ® For Approval ? Destroy Previously Sent Drawings ? For Reference Only ? For Bids Due REMARKS: ATTACHED ARE THE REQUIRED ALARM/ SIGNALING DRAWINGS FOR AUDACIOUS. PLEASE CALL WITH ANY QUESTIONS. THANKS. SIGNED: AL BORNSTEIN CC: FILE 93o5implex Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; IDNetTM or MAPNET Ile Communicating Devices MEA (NYC) Acceptance* Addressable Manual Stations Individually addressable manual fire alarm stations with: • Power and data supplied via IDNet or MAPNET 11 addressable communications using a single wire pair** - • Operation that complies with ADA requirements • Pull lever that protrudes when alarmed • Break-rod supplied (use is optional) J • Models are available with single or double action (breakglass or push) operation 4099-9001 Addressable Manual Station • UL listed to Standard 38 (front and side view) Compatible with the following Simplex° control - panels: l r _ ! ! • Model Series 4008, 4010, 41000, 4020, 4100, and 4120 fire alarm control panels equipped with either IDNet or MAPNET 11 communications OPIRAT III ONLY • Model Series 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Compact construction: 4099-9002 4099-9003 With 2099-9828 • Electronics module enclosure minimizes dust Institutional Breakglass Push Cover kit infiltration Allows mounting in standard electrical boxes • • Screw terminals for wiring connections Activation of the Simplex 4099-9001 single manual station requires a firm downward pull to activate the Tamper resistant reset key lock (keyed same as alarm switch. Completing the action breaks an internal Simplex hire alarm cabinets) plastic break-rod (visible below the pull lever, use is Multiple mounting options: optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull • Surface or semi-flush with standard boxes or requirements needed for easy activation. The pull lever matching Simplex boxes latches into the alarm position and remains extended out • Flush mount adapter kit of the housing to provide a visible indication. • Adapters are available for retrofitting to commonly Double Action Stations (Breakglass) require the available existing boxes operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. The Simplex model 4099-9001 addressable station Double Action Stations (Push Type) require that a combines the familiar Simplex manual station housing spring loaded interference plate (marked PUSH) be with a compact communication module that is easily pushed back to access the pull lever of the single action installed to satisfy demanding applications. Its integral station. individual addressable module (IAM) constantly monitors status and communicates changes to the connected control Station reset requires the use of a key to reset the panel via 1DNet or MAPNET 11 communications wiring. manual station lever and deactivate the alarm switch. (If the break-rod is used, it must be replaced.) * Refer to page 2 for specific model listings. This product has been approved by the Station testing is performed by physical activation of California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health the pull lever. Electrical testing can be also performed by and Safety Code. See CSFM Listing 7150-0026:224 for allowable values andlor conditions concerning material presented in this document. It is subject to re-examination, revision, unlocking the station housing to activate the alarm switch. and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E Additional listings may be applicable; contact your local Simplex product MAPNET II addressable communications designs are protected by U.S. supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are IDNet patent anNo. d nd 4,796,025; 5,966,002; and mmun601. the property of Tyco Safety Products Westminster. S4099-0001-7 5/2006 Addressable Manual Stations, Red Housing with White Letters and White Pull Lever Model Description Housing Pull Lever Listings 4099-9001 Single action, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM, MEA 4099-9001 CB Single action, Bilingual English and French FEU FIRE TIREZ PULL 4099-9001CF Single action, French ALARME FEU ABAISSEZ ULC, FM 4099-9002 Double action, Breakglass operation, English 4099-9003 Double action, Push operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM, MEA Accessories Model Description 2975-9178 Surface mount steel box, red 2975-9022 Cast aluminum surface mount box, red Refer to page 3 for dimensions 2099-9813 Semi-flush trim plate for double gang switch box, red 2099-9814 Surface trim plate for Wiremold box V5744-2, red Typically for retrofit, refer to page 4 2099-9819 Flush mount adapter kit, black Refer to page 4 for details 2099-9820 Flush mount adapter kit, beige 2099-9803 Replacement breakglass 2099-9804 Replacement break-rod 2099-9828 Institutional cover kit for field installation on 4099-9001 Power and Communications IDNet or MAPNET II communications, 1 address per station Address Means Dipswitch, 8 position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire UL Listed Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan® polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5" H x 3-3/4" W x 1" D (127 mm x 95 mm x 25 mm) • . • Single Gang Box Mount 4" Square Box Mount Single gang box, 2-1/2" deep 4" (102 mm) square box, 2-1/8" (54 mm) minimum (64 mm), RACO #500 or equal depth, RACO #231 or equal (supplied by others) (supplied by others) 0 o Mount flush or with o ri 1/16"(2 mm) maximum extension ° o DO NOT RECESS 4" Square box with cover plate U J o O i i Station FIRE ®ALARM side view Single gang cover plate, 3/4" (19 mm) extension, RACO #773 PULL DOWN or equal (supplied by others) 1 Single gang box outline Wall surface Semi-Flush Mount Side View O Simplex 2 S4099-0001-7 5/2006 Er-re 2975-9178 Box 2975-9022 Cast Box Preferred Mounting. For 5-3/16" H x 4" W x 2-3/16" D 5" H x 3-7/8" W x 2-3/16" D (1 surface mounting of these 32 (omm x 102 mm x rdered separately) mm) (127 (ordmm x eeds semm x 56 parately) m) addressable manual stations, the ( preferred electrical boxes are shown in the illustration to the right. 0 0 0 0 Additional Mounting Knockouts located Reference. Refer to page 4 for top and bottom Wiremold box mounting compatibility. FIRE ®ALARM 0 0 PULL DOWN Access for 3/4" threaded 5.. conduit located top and bottom (127 mm) Simplex 1" (25.4 mm) ~3-3/4" (95 mm)~ 4099 Series Addressable Manual Station • • Refer to NFPA 72, the National Fire Alarm Code, and all applicable local 1-1/4" codes for complete requirements for (32 mm) Simplex 2975-9178 box manual stations. The following Field wiring (shown for reference) ~ Z (shown for reference) summarizes the basic requirements. 1. Stations shall be located in the normal path of exit and distributed in the protected area such that they Address setting under - are unobstructed and readily resealable label (accessible accessible. with cover open) 2-5/8^ 2. Mounting shall be with the (67 mm) operable part not less than 3-1/2 ft (1.1 m) and not more than 4-1/2 ft Station cover (1.37 m) above floor level. hinges open for installation access \ 3. At least one station shall be \11 provided on each floor. Additional Switch wiring stations shall be provided to obtain (prewired) a travel distance not more than 200 ft (61 m) to the nearest station from any point in the building. 4. When manual station coverage appears limited in any way, additional stations should be installed. 3 S4099-0001-7 5/2006 - For retrofit and new installations, additional 0 0 compatible mounting boxes Wiremold o o receptacle box and the required adapter plates 2099-9814 Surface trim model V5744-2 are shown in the illustration to for Wiremold box (supplied by the right. 5-1/8" H x 5" W others) (130 mm x 127 mm) 0 0 j o o Two gang switch box, each 3" H x 2" W x 2-3/4" D (76 mm x 51 mm x 70 mm) c_ - (supplied by others) 4099-90011DNet o / addressable station o o°' 2099-9813 Semi-flush trim for 2 gang o EZ=) o switch box, 6" H x 4-1/2" W (152 mm x 114 mm) Flush mount adapter kit 2099-9819, Black 2099-9820, Beige Box must be recessed into wall 1" to 1-1/8" (25.4 mm to 29 mm) ,sp.,..se.t9 v (203 mm) O _ Hole cutout must be a ' minimum of 6" H by 5" W 6" (152 mm by 127 mm) (152 mm) i 4-11/16" (119 mm) square box, 2-1/8" (54 mm) minimum - Wall depth (by others) I 4-3/4" (121 mm) . surface 6-3/4"(171 mm) Front View Side View l jra, Simplex, the Simplex logo, MAl'NIA 11, and IONet are trademarks Tyco intermmional Semces AG or its aJfiliaie.s in the U.S. and or other countries. NFPA 72 and National hire Alarm Code are registered trademarks aJ7he National 1 ,ire Proteenon Association (NM A). Lexan is a trademark at the General Electric Co. Wiremold is a trademark of the Wiremold Company. ®Simplex Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4099-0001-7 5/2006 www.tycosafetyproducts-usa-wm.com 1 ' 2006 Yyco Safetvl'roducts Westminster. All rights reserved All spec cations and other injormation shown were current as ofdommeni revision (late and are subject io change without notice. 6,,Simplex TrueAlert® Multi-Candela Notification Appliances UL, ULC Listed, FM Visible Notification Appliances with Horn and Synchronized and CSFM Approved* Flash; Non-Addressable, SmartSynCTM Operation Compatible . Audiblelvisible (AN) notification appliances with ~ efficient electronic horn and high output xenon strobe, available for wall or ceiling mount • Operation is compatible with ADA requirements (refer to important installation information on page 3) • Rugged, high impact, flame retardant thermoplastic f housings are available in red or white with clear lens f Operates over a two-wire SmartSync circuit to °u provide: r • Horns that are controlled separately from strobes on the same two-wire circuit _ • "On-until-silenced" and "on-until-reset" operation on - the same two-wire pair I • Horn control that can be selected to be temporal coded, march time coded, or on continuously • Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate • Class R (Style Y) operation requires connection to a compatible SmartSync NAC or to SmartSync Control Wall and Ceiling Mount A/Vs Modulo; (SCM) 4905-9938 ~ • Class A (Style Z) operation when connected to the 4905-9938 SCM or with 4100U series fire alarm control Multi-Candela TrueAlert ANs with horn and panel938 synchronized strobe provide convenient installation NACs to standard electrical boxes. The enclosure designs are Wall mount ANs features: both impact and vandal resistant and provide a convenient • Wiring terminals are accessible from the front of the strobe intensity selection. Since each model can be housing providing easy access for installation, selected for strobe intensity output, on-site model inspection, and testing inventory is minimized and changes encountered during • Covers are available separately to convert housing color construction can be easily accommodated. Optional adapters and wire guards: Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or • Wall mount AN adapters are available to cover surface 4" square standard electrical box. The cover can be mounted electrical boxes and to adapt to Simplex- quickly removed (a tool is required) and covers are 2975-9145 boxes available separately for color conversion. • UL listed red wire guards are available for wall or ceiling mount A/Vs Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is determined by model number. Visible notification appliance (strobe): • 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured During installation, a selection plug at the back of the behind strobe housing housing detennines the desired strobe intensity. An • UL listed to Standard 1971 attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the • Regulated circuit design ensures consistent flash output side of the strobe lens. and provides controlled inrush current This product has been approved by the California State Fire Marshal (CSFM) pursuant to Audible notification appliance (horn): Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:317 for allowable values and/or conditions concerning material presented in this • Low current, 24 VDC electronic horn with harmonically document. It is subject to re-examination, revision, and possible cancellation. This product rich Output SOUrid suitable for either coded or Stead was not approved by MEA (NYC) as of document revision date. Refer to page 2 for listing rich y status of wire guards. Additional listings may be applicable; contact your local Simplex operation product supplier for the latest status. Listings and approvals under Simplex Time Recorder • UL listed to Standard 464 Co. are the property of Tyco Safety Products Westminster. " Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5,559,492 and SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789. S4906-0002-2 9/2004 • • Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy, location, local codes, and proper applications provide the ability to activate both the horn and strobe on of. the National Fire Alarm Code (NFPA 72), ANSI the same NAC and then allow the horn to be silenced A117.1; the appropriate model building code: BOCA, while the strobe remains flashing. The horn operates as ICBO, or SBCCI; and the application guidelines of the "on-until-silenced" while the strobe operation is Americans with Disabilities Act (ADA). "on-until-reset." • • • • • &TTITM Multiple Strobes. When multiple strobes and their • 41000 and 4010 Fire Alarm Control Panels (refer to reflections can be seen from one location, synchronized data sheet 54010-0001 for details; refer to data sheet flashes reduce the probability of photo-sensitive reactions 54 1 00-003 1 for basic 41001] information) as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender (refer to data sheet random flashing. The multi-candela strobes of these ANs S4009-0002) are synchronized by the controlling SmartSync operation . SmartSync Control Module (SCM) 4905-9938 (refer to NAC. data sheet 54905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Multi-Candela A/Vs Model Mounting Housing Color "FIRE" Lettering Description 4906-9127 Wall Red White 4906-9129 White Red Horn with Multi-Candela Strobe; strobe intensity selectable as: 4906-9128 Red White 15, 30, 75, or 110 candela; operates with SmartSync two-wire 4906-9130 Ceiling White Red control Wall Mount AN Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep 5-3/8" H x 5-1/4" W x 1-5/8" D surface mounted boxes (136 mm x 133 mm x 41 mm) 4905-9940 White depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount ANs Model Description Dimensions 4905-9994 Red cover with white "FIRE" lettering 5-1/8" H x 5" W x 1-1/2" D 4905-9995 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimensions 4905-9961* Wall mount red wire guard with mounting plate, compatible with semi-flush 6-1/16" H x 6-1/16" W x 3-1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2" x 6-1/8" x 3" (216 mm x 156 mm x 76 mm) 4905-9928- Ceiling Red Adapter Plate, required to mount guard to surface 9" x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 4-3/4" x 6-7/8" x 1-1/2" deep, 4905-9916 [Red 1-1/2" deep surface mounted boxes (121 mm x 175 mm x 38 mm) * UL listed by Space Age Electronics Inc. 2 S4906-0002-2 9/2004 • Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm' to 3.31 mm2) ; two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Voltage 16 VDC 24 VDC 33 VDC Sound Type (see Note 2) Steady Coded Steady Coded Steady Coded Horn Output Ratings @ 10 ft (3 m) Reverberant Chamber, 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA UL 464 Test Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5-1/8" H x 5" W x 2-3/4" D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Mount Strobe Setting (see Note 3 below) 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC 70 mA 101 mA 184 mA 243 mA at other voltages 24 VDC 60 mA 84 mA 143 mA 185 mA Housing Dimensions (with lens) 4-3/4 L" x 6-7/8" W x 2-5/8" D (121 mm x 175 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting (see Note 3 below) 86 mA 132 mA 250 mA 320 mA Mount Reference RMS Currents 18 VDC 81 mA 119 mA 216 mA 283 mA at other voltages 24 VDC 70 mA 97 mA 167 mA 217 mA NOTES: 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. 3. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) 0 0 Mounting is compatible with 1 0 1 r IMPORTANT! WALL MOUNT single gang, double gang, and a" (102 mm) square boxes, INSTALLATION HEIGHT REFERENCE 1-1/2" (38 mm) deep, by others o 0 0 Bottom of lens is either even with, or slightly Electrical or- 0 0 0 above bottom box outline Wiring access hole of compatible boxes Wiring terminals for tt p ° SmartSync operation ° * Mounting Holes: NFPA 72 requires 80" (2.03 m) a" square (4) that the entire lens minimum Single gang (2) be not less than Double gang (3) 80" and not greater than 96" above the Transparent housing finished floor and lens assembly Intensity selection plug, accessible only from rear of housing; 15 n factory setting is 15 cd Removable] cover Strobe intensity (tool required) viewing slot 3 S4906-0002-2 9/2004 Ceiling reference, 4" (102 mm) square box, Optional 4905-9928 Adapter Plate, surface mounted box 1-1/2" (38 mm) minimum depth required for surface mounted electrical box\ Four mounting clamps included, two each side 1 0 ° Ceiling reference, flush mounted box 0 Optional 4905-9915/-9916 Adapter, recommended for surface mounted box - Wiring terminals are Optional 4905-9927 , located behind the housing Red Wire Guard End View Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and O box shown for reference 4"(102 mm) square m~~ O box profile, 1-1/2" ; - (38 mm) deep J Optional O O _ 4905-9961 Wire Guard Imo{ AN 0 0 J U 4905-9931 Adapter Plate Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2" deep: 4905-9937, Red; (shown here for reference only, 4905-9940, White (conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tvco, Simplex, the Simplex logo, rDNet, TrveAlert, and SmarlSync are trademarks of Tvco huernational AG or its a/filiates in the U.S. andlor other countries. NFPA 72 and National Fire Alarm Code are registered trademarks q/ the National Fire Protection Association (,VFPA). 93,,Simplex Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4906-0002-2 9/2004 www.tycosafetyproducts-usa-wm.com 0 2004 Tvco Safety Products Westminster. All rights reserved All specifications and other infi nnution shown were current as ofdocument recision dote and are subject to change nwthout notice. G,,,Simplex TrueA/ert® Multi-Candela Notification Appliances UL, ULC Listed; FM Visible Notification Appliances with Synchronized Flash; and CSFM Approved* Non-Addressable, SmartSynCTIM Operation Compatible Visible only (VIO) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: • UL listed to Standard 1971 - • Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing • Operation is compatible with ADA requirements (refer to important installation information on page 3)~ • Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Wall Mount Strobes • Regulated circuit design ensures consistent flash output and provides controlled im-ush currcnt • Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Strobes provide synchronized flash for use with: • 4010 Series and 4100U Series fire alarm control panels Ceiling Mount Strobes with N ACs selected to provide strobe synchronization or SmartSync two-wire control** • • • 4009 IDNetTm NAC Extenders Multi-Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes. The enclosure designs are both impact and vandal • Separate SmartSync Control Modules (SCMs) that resistant and provide a convenient strobe intensity provide Class B or Class A output from conventional selection. Since each model can be selected for intensity NAC inputs output, on-site model inventory is minimized and changes encountered during construction can be easily Strobe housings provides flexible, easy, and accommodated. convenient semi-flush or surface wall mounting: Wall mount strobe housings are a one-piece assembly • Rear of housing does not extend into box (including lens) that mounts to a single or double gang, or • Wall mount strobes easily mount to single gang, double 4" square standard electrical box. The cover can be gang, or 4-inch square outlet box quickly removed (a tool is required) and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model • Wiring terminals are accessible from the front of the number. housing providing easy access for installation, inspection, and testing Mm. a - MUM • Covers are available separately to convert housing color During installation, a selection plug at the back of the Optional adapters and wire guards: housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow • Wall mount strobe adapters are available to cover background allows the selected intensity to be seen at the surface mounted electrical boxes and to adapt to side of the strobe lens. Simplex' 2975-9145 boxes F-Iff-MR-Mg [m. m. 11MM"M • UL listed red wire guards are available for wall or ceiling mount strobes Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications This product has been approved by the California State Fire Marshal (CSFM) pursuant to of: the National Fire Alarm Code (N FPA 72), ANSI Section 13144.1 of the Cal'rfomia Health and Safety Code. See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning material presented in A 117.1; the appropriate model building code: BOCA, this document. It is subject to re-examination, revision, and possible cancellation. This ICBO, or SBCCI; and the application guidelines of the product was not approved by (NYC) as of document revision date. Refer to page 2 for Americans with Disabilities Act (ADA). listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time " Two-wire strobe synchronization operation is protected by U.S. Patent No. 5,559,492; Recorder Co. are the property of Tyco Safety Products Westminster. SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789; strobe designs are also protected under U.S. Patent Nos. 5,886,620; 5,622,427; and 5,865,527. S4906-0001-1 8/2004 Multiple Strobes. When multiple strobes and their Class B SmartSync two-wire control is available reflections can be seen from one location, synchronized from: flashes reduce the probability of photo-sensitive reactions . 41000 and 4010 Fire Alarm Control Panels; 4010 as well as the annoyance and possible distraction of panels require operating software Revision 2.X or random flashing. These multi-candela strobes are higher (refer to data sheet 54010-0001 for details; refer synchronized over a two-wire circuit when connected to to data sheet S4100-0031 for basic 4 f OOU information) compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. • 4009 IDNet NAC Extender, models 4009-9201 and 4009-9301 (refer to data sheet S4009-0002) • • • • SmartSync Control Module (SCM) 4905-9938, converts separate conventional horn and strobe NAC Some applications desire the audible notification inputs into a SmartSync NAC output; up to eight SCMs appliances to be capable of being silenced before the can be synchronized to each other alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the Class A SmartSync two-wire control is available alarm condition is reset (on-until-reset). SmartSync from 4100U NACs and from the 4905-9938 SCM. operation mode provides this function using a single Additional SmartSync compatible notification circuit (two-wire operation). appliances include separate horns and combination horn/strobe notification appliances. Multi-Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color "FIRE" Lettering Description 4906-9101 Red White 4906 9103 Wall White Red Multi-candela strobe with intensity selectable as: 4906-9102 Red White 15, 30, 75, or 110 candela; synchronized flash rate; 4906-9104 Ceiling White Red SmartSync two-wire control compatible Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) 5-3/8" H x 5-1/4" W x 1-5/8" D dee surface mounted boxes (136 mm x 133 mm x 41 mm) 4905-9940 White p Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8" x 3-1/8" x 0.060" D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with 1-318" x 2-7/16" x 13/16" in/out 18 AWG (0.82 mm) wire leads, rated for 2 A NAC, 4905-9922 Class A requires 10 mA for power (35 mm x 62 mm x 20 mm) 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4-1/8" x 1-1/4" D 4" (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white "FIRE" lettering For 5-1/8" H x 5" W x 1-1/2" D 4905-9993 White cover with red "FIRE" lettering Wall mount strobes (130 mm x 127 mm x 38 mm) 4905-9961' Wall mount 6-1/16" H x 6-1/16" W x 3-1/8" D Red wire guard with mounting plate, compatible with (154 mm x 154 mm x 79 mm) 4905-9926` Ceiling mount semi-flush or surface mounted boxes 6-1/8" x 4-3/8" x 2-7/8" deep (156 mm x 111 mm x 73 mm) ' UL listed by Space Age Electronics Inc. 2 S4906-0001-1 8/2004 Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32' to 122° F (0' to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mmz to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8" H x 5" W x 2-3/4" D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Strobe Setting (see Note 2 below) 60 mA 94 mA 186 mA 252 mA Mount Reference RIMS Currents 18 VDC 55 mA 85 mA 169 mA 226 mA at other voltages 24 VDC 41 mA 63 mA 123 mA 164 mA Housing Dimensions (with lens) 4-3/4" L x 2-5/16" W x 2-5/8" D (121 mm x 75 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting (see Note 2 below) 75 mA 125 mA 233 mA 316 mA Mount Reference RMS Currents 18 VDC 64 mA 102 mA 199 mA 266 mA at other voltages 24 VDC 49 mA 76 mA 146 mA 195 mA NOTES: 1. "Regulated 24 VDC' refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) • RFTR 0 0 Mounting is compatible with \ 0 \ r single gang, double gang, and 1 1 4" (102 mm) square boxes, o `moo 1-1/2" (38 mm) deep, by others 0 0 = c IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even TM~an 0 o Q 08 with, or slightly Electrical box outline Wiring access hole above bottom of compatible o boxes Wiring terminals 1-- 1---7 Mounting Holes: 4" square (4) NFPA 72 requires 80" (2.03 m) 4p°°'aeA " ® Single gang (2) that the entire lens minimum Double gang (3) be not less than 80" and not greater than 96" above the Transparent housing finished floor and lens assembly Intensity selection plug, accessible only from rear of housing; t5 factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0001-1 8/2004 Handy box, 1-1/2" ( 38 mm) deep Single gLox Wiremold (RACO 650 or equal) or single gang V574457 mm) box, 2-1/2" (64 mm) deep (RACO 519 deep, y others or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) U 0 0 4905-9910 Adapter Plate, required for surface mount with handy box unless using the 4905-9926 wire guard Ceiling mount strobe O Optional 4905-9926 wire guard U ~1 with mounting plate Strobe intensity i ter viewing slot i Intensity selection plug, accessible only from rear of lens' i i housing; factory setting is 15 cd ` Surface Mounting Reference C; 2975-9145 Box with Optional Adapter Skirt and Optional Wire Guard O Surface mount conduit and O box shown for reference 4" (102 mm) square r box profile, 1-112" U (38 mm) deep Optional O - - O 4905-9961 Wire Guard Strobe o [ OHE 4905-9931 Adapter Plate Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2" deep: 4905-9937, Red; (shown here for reference only, 4905-9940, White (conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tvco, Simplex, the Simplex logo, IDNei. TrveAlert, and Smart Sync are trademarks of -Tyco international AG or its affiliates in the U.S. and/or other countries. NFPA 72 and (Naattiional Fire Alarm Code are registered trademarks of the National Fire Protection .4ssociation (NFPA). i1®Simplex Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4906-0001-1 8/2004 www.tycosafetyproducts-usa-wm.com © 2004 Tyco Safety Prochrets Wesnninstc r. All righls resenvd. All specifications and other information shown were current as of document recision dote and are subject to change without notice.