Loading...
07201471 Permit File Office CITY OF DUBLIN f4's J Dies ilding Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 0T if 6 2001 WTFD: (614) 652-3920 t_ y ; ,;,I? ~j~j FIRE PROTECTION PERMIT APPLICATION Application Date f l Bldg. App. # C)l 201400 Fire Protection App. # PROJECT INFORMATION 1 / Project Address _ - - J r ~ Project Name Owner/Tenant Contact Name Telephone APPLICANT INFORMATION Fire Protection Contractor le C_ 1 y Address L G Ar 11!21.1 Telephone 6/9 - 3 2 E. -3S 0 State Certificate Number r) 3J 2 ci Dublin Registration Number 07- L19?_ ) Installer Name - ~JEI State Certificate Number SLI Z~) C4 SCOPE OF WORK v (Mark One) New Replace Repair Alteration FIRE DETECTION AND ALARM SYSTEM (Number of Each) Detectors Strobes 'z Horns Fire Alarm Boxes Other SUPPRESSION SYSTEM (Number of Each) Standpipes On Site Water Piping Sprinkler Heads Limited Area Other FEES FIRE DETECTION OR SUPPRESSION PERMIT PROCESSING FEE $60.00 LOW VOLTAGE PERMIT (DETECTION ONLY) $30.00 Minimum fee plus $20.00 each 1,000 sq ft or fraction thereof over 1,000 sq ft OUTSIDE PLAN REVIEW SERVICES (EXAMINER'S FEE AS CHARGED) STATE SURCHARGE (3%) TOTAL FEE DUE This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. This permit conveys no right to open any street, alley or sidewalk or any part thereof, nor o make any connection to a water main. Signature of Licensed Contractor - r DATE 3z0 Print Name _ (Imt `rr'~ DATE FOR OFFICIAL USE ONLY Review Comments: The 9r exlewS/ r~ OWAr ,66 IT? 14f r . X *J10 Department: A/r A shq Date: /O y` 0 7 Examiner: Date: 01 by CBO: << Date: I lT l '7 CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00201471 Date 10/12/07 Property Address . . . . . . 6397 EMERALD PKY Parcel Number: 273-007659 Alternate Address: TUTTLE CROSSING NORTH Tenant nbr, name . . . . . . HULL & ASSOC. DETECTION Application type description FIRE PROTECTION Property owner . . . . . . . DUKE REALTY OHIO Contractor . . . . . . . . . COMPETENT ELECTRICAL SERVICES Permit . . . . . . FIRE DETECTION PERMIT Additional desc . . Permit Fee . . . . 60.00 Plan Check Fee .00 Issue Date . . . . ~L7 /CD-v7 Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 60.00 Special Notes and Comments CONTACT WASHINGTON TOWNSHIP FIRE PREVENTION FOR INSPECTIONS AT 766-0857 Other Fees . . . . . . . . . SURCHARGE FEE - FIRE 1.80 ----------------7----------------------------------------------------------- Fee summary Charged Paid Credited Due Permit Fee Total 60.00 .00 .00 60.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 1.80 .00 .00 1.80 Grand Total 61.80 .00 .00 61.80 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. GENTEX CORPORATION Commander3 Series Selectable GEC3/GES3 Candela Evacuation Signals 12 & 24 VDC Applications S E R I E S The Commander3 Series is a low profile strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The 12VDC offers tamperproof field selectable w r candela options of 15, 30, 60, and 75 candela. The Commander3 Series horn offers a continuous or synchable temporal three in , 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy for Illlllll? the professional to change in the field by using switches. J The GE3 Series has a minimal operation current and has a minimum flash rate of 1 Hz regardless of input voltage. The Commander3 Series is shipped with the standard 4" mounting plate which Product Listings incorporates the popular Super-Slide" feature that allows the installer to easily test for supervision. The product also features a locking mechanism which F ~ C11: M secures the product to the bracket without any screws showing. ...moo TI- y,,K " c+r 1 prur, V, -pl.tn rcwn. n :.s - The Commander3 also features the CheckmateT' - Instant Voltage Verification ` n""` UNOERWR!TERS LA90RATORIES NC feature which allows the installer to check the voltage drop draw and match it to BFP (City of Chicago) the blueprint. BS+A/MEA #285-91-E • CSFM 7135-0569:122 (GEC3-24 & GEH-24) 7125-0569:123 (GES3-24) The GE3 Series appliances are UL 464 and UL 1971, listed for use with fire pro- 7125-0569:129 (GES3-12) tective systems and are warranted for three years from date of purchase. 7135-0569:130 (GEC3-12 & GEH-12) Standard Features • FM Approved • UL 464 & UL 1971 Listed • Nominal Voltage 12 & 24 VDC • CAN/ULC S526-M87 Listed • 24 VDC units have field selectable candela options of ULSZ7.S3406 Listed (GEC3-24, 15, 30, 60, 75, and 110 candela GEH24 & GEH12) • 12 VDC units have field selectable candela options of Product Compliance 15, 30, 60, and 75 candela • NFPA 72 • GEH horn is available in 12 or 24 Volt • Americans with Disabilities Act (ADA) • Super-SlideT"' Bracket - Ease of Supervision Testing • CheckmateTM - Instant Voltage Verification e;= • Unit Dimensions: 5" high x 4.5" wide x 2.5" deep >SSEURED N • Synchronize Strobe and/or Horn with Gentex Series NE USA Control Module (12 Volt product must use the AVSM • Switch for Continuous or Temporal 3 (not available on Module) whoop tone) • Prewire Entire System, Then Install Your Signals • Surface Mount with the GSB (Gentex Surface • Lower Installation and Operating Costs Mount Box) • Input Terminals 12 to 18 AWG • Silence Horn While Strobes Remain Flashing • Switch Selection for High or Low dBA • Wide Voltage Range 8-17.5 VDC (12 Volt Models) • Switch for Chime, Whoop, Mechanical and 2400Hz Tone 16-33 VDC or FWR (24 Volt Models) • Tamperproof Re-entrant Grill 9 Faceplate Available in Red or Off-White GEH 12 or 24 Volt Low Profile Evacuation Horn Model Number a Number Nominal Reverberant In nec oic Room Voltage 1Oft. Per UL 464, dBA @1 Oft. EH12-W 904-1241-007- 12 VDG 62-82 100 EH24-H 904-1205-007- 24 VDC; 62-82 100 GES3 12 or 24 Volt Selectable Candela Low Profile Evacuation Strobe Model Number a Number Nominal Candela Voltage (UL 1971) Model designations: GES3-12WR -1 - 1 5 "W" = Wall Mount "R" = Red Faceplate GES3-12WW 904-1237-150- --TTVD-T- 15, 30, 9677- - "W" = Off-White Faceplate "P" = Plain (no lettering) Available E53-12PWW 904-1238-002 12 VDC; 15,30,60,75 with all models. ES3-24WW 904-1319-MT-- 24 VDC 15, 30, 60, 75, 110 These units are non-returnable. "Agent" bezel also available. E53-24PWW 904-1320-MY- 24 VDC; 15, 30, 60, 75, 110 GEC3 12 or 24 Volt Selectable Candela Low Profile Evacuation Horn/Strobe Model Number a Number Nominal Candela Reverberant In nec oic Room Voltage (UL 1971) 1Oft Per UL 4641 dBA @ 1Oft. GEC3-12WR 904-1231-0 -7TVD7-- 15, 30, 60,7r- 62-82 100 UEG3-12WW 002 12 VDG 15,30,60,75 62-82 100 GEC3-12PWH 904-1232-002 fTV= 15,30,60,77- 62-82 100 EC3-12PWW 904-1234-002 12 VDC 15,30,60,75 62-82 100 E(;3-24WR 904-1317-007- -'7TV= 15, 30,60, 75,110 62-82 107- EG3-24PWR 904-1318-002 5,110 62-82 100 EG3-24PWW__, 904-1316-007-1-777D7-1 15, 30, 60, 79_,fTU_, 62-82 100 Notes: • The GE3 Series is not listed for outdoor use. • Operating temperature: 32°to 120°F (0° to 49° C). • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. 12 volt models are DC only. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see Technical Bulletin Number 014). Product Strobe Current Ratings GE:3-24 Product Strobe Current Ratings an e a c c c c Candela c c c c c 12 YDC m m m m m m m m m ax m TfrMW 331 m m ax m m m m m Product Horn Current Ratings GE3-24 Product Horn Current Ratings Horn Mode Minimum Minimum Regulated Horn Mode Minimum Minimum Regulated dBA @ 1Oft. dBA @ loft. 12VDC Max. dBA @ loft. dBA @ 1011t. 24VDC Max. per UL464 per UL464 Operating @ per UL464 per UL464 Operating (HIGH) (LOW) High Setting (mA) (HIGH) (LOW) High Setting (mA) emp z 29 emp z 28 emp Mechanical emp ec anica emp Chime 62* 60* 13 emp Chime 70* 66* 15 ontinuous z 7 29 ontmuous z 28 ontmuous Mechanical ontmuous ec anica ontinuous Chime 13 ontinuous ime 15 [Whoop 55 [Whoop 56 'Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level required for public mode fire protection service. These set- tings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. To obtain the horn/strobe current draw, add the strobe current draw and the horn current draw. i The listed reverberant dBA are for the Continuous Tone mode. The Temporal 3 Tone has a reverberant dBA @ 1 Oft, per UL 464 is 77-83 with a horn current draw of 34mA. 2 RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units) (8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. Mounting Super-Slide"m Switch Locations SVVITCH POSITION 3 a 5 Meffi anica4Terrp ON ON 47N . F j Mec Temp ont N Hi H-Temp. OF.I OFF ON HFCant OFF GFF ON Chime -Temp ON ON OFF t Chim~Cont OFF ON OFF Wnoop ON OFF OFF a E Moop O=F OFF OFF Switch Position 6 L ' ON > HIGH dB w ll i K OFF> LOW dB Switch positions 1 and 2 l i In the off position to select isolated horn and strobe It power inputs. Die Cast Metal Mounting Plate: Mounts to single gang, double gang 4" square boxes or GSB box. I \ ON I~ Checkmate TM - Instant Voltage Verification ell ~ 2 3 4 5 6 S+ ! y' Candela Selection I S- [~I~ t II lL Candela selection slider : Oct-. Depress center and slide svotch to desired brightness ie,A E t E The access holes are provided in the back of the terminal Break off pir and irserl ir,o 15 y hole at the bottom of the 78 II block to allow the voltage to be measured directly without w -r ` J select or to lock candela settlcg 75 Il removing the device. Typically this would be done at the Signal must be removed from +0 bradtei and pin pushed farward w s lechon end of the line to confirm design criteria. Most measure- from backside out of hole marker merits will be taken using the S+ and S- locations to char ge can de la. although access is provided to other locations. NOTE: Care should be taken to not short the test probes. Conventional GES3/GEC3 Series Wiring Diagrams UL Listed UL Listed Control Control Signal Signal Panel Signal Signal Panel s+ s+ s- H+ H- s+ s+ s- H+ H- S+ S+ S- H+ H- S+ S+ S- H+ H- Supervised 0 0 0 0 Supervised Signal Circuit Signal Circuit \ + _T (-A LJ \ + END LINE IS END OF LINE RESISTOR RESISTOR \ + OR ENO ROF UNE RESIS ESISTOR Wiring Diagram GE3 Series with Gentex Synchronization Module F.A.C.P. IF ENO Of LINE - REND 0f FOR TO NEXT SIGNAL F- TO NOTIFICATION ALARM CIRCUIT CIA%R f WIRING ONLY. C__ TO NEXT SIGNAL TO NOTIFCATION ALARM CIRCUIT REMOVEJUMPER FORINDEPENDENT SYNCHRONIZED STROBE ENO OF LINE AUDIBLE SIGNAL + RESISTOR FoR AND HORN OPERATION CIRCUIT -sa LEAVE JUMPERIN PLACE SYNCHRONIZATION vRRINC a+LV. TO ELIMINATE NEED FOR MODULE HORN INPUT ON AVSM LEAVE JUMPER IN PLACE ON ® AND OPERATE SIGNAL SLAVE UNITS UNLESS SEPARATE IN UNISON MODE CONTROL OVER HORN CKT « ®00 IS REQUIRED. SYNCHRONIZATION MODULE Signal Signal S+ S+ S. H+ H- S+ S+ S- H+ H- e ~ 1P 'Si s VISIBLE SIGNAL + ENDOFuNE RESISTOR FOR CIRCUIT J I cLwsse I WIRNG ONLY I I I I ~ I END OF LINE + ________i i RE95TOR FOR I 1 Cw. A WRING ONLY. - Note: See Technical Bulletin 015 for proper synchronization module for application. Note: When synchronizing the GE3 12 VDC Series, the AVSM synchronization module MUST be used. Architect & Engineering Specifications: The audible and/or visible signal shall be Gentex GE3 Series or approved equal and shall be listed by Underwriters Laboratories Inc. per UL 1971 and/or UL 464. The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audible/visible) shall produce a peak sound output of 100dBA or greater at 12 or 24V as measured in an ane- choic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the abil- ity to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2 Hz regardless of power input voltage. The appliance shall have an operating current of 55mA or less at 24 VDC for the 15Cd strobe circuit and 106mA or less at 12 VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with termi- nals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models or a voltage range of 8-17.5 volts for 12 volt models. The appliance shall be capable of testing supervision without disconnecting wires. Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. 24 units per carton 28 pounds per carton Important Notice' G E N T E X These materials have been prepared by Gentex Corporation Gentex') for informational purposes only, are 551-0050-02 necessarily summary, and are not purported to serve as legal l advice and should not be used as such. Gentex makes no representations and warranties, express or implied, that these materials are complete CORPORATION and accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal considerations as there Is inevitable uncertainty regarding interpretation of laws, regulations and rules and the application of such laws, regulations and rules to partic- Fire Protection Products: www.gentex.com ular fact patterns. Each person's activities can differently affect the obligations that exist under applicable laws, regulations or rules. Therefore, these materials should be used only for informational purposes and 10985 Chicago Drive Box 310 • Zeeland, Michigan 49464 should not be used as a substitute for seeking professional legal advice. Centex will not be responsible for 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax any action or failure to act in reliance upon the information contained in this material.