07201499 Permit File CITY OF DUBLIN 91e-" Jl"r 1~o Of ccc @ N ion of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 OCT 1 2 2007 WTFD: (614) 889-2347 iJ' ~ I r ~J~ _ FIRE PROTECTION PERMIT APPLICATION /LAG Application Date GGC I ( I Bldg. App. #d7-0t00Q18' Fire Protection App. # L AIL/ ! I PROJECT INFORMATION 1t Project Address 6 ; ~l16 le of Project Name tUT-iCl1q1 M4 (0 ~ Owner/Tenant Contact Name Q for Ban Telephone APPLICANT INFORMATION Fire Protection Contractor Je_Jyi C RxcQ-f C ild UPS (6 N3 Address °755-2 _t"L t A-NC C- f j_ Vii';;' 1 &W Telephone W1 - ticaj o State Certificate Number 5 - - 1 3 Dublin Registration Number g"541g Installer Name 1'%M0k l_~ M+ t h State Certificate Number_ 54 - 2.5 - a 1$ b SCOPE OF WORK / (Mark One) New ? Replace Repair Alteration FIRE DETECTION AND ALARM SYSTEM (Number of Each) Detectors a Strobes Horns Fire Alarm Boxes Other ?`1 SUPPRESSION SYSTEM (Number of Each) Standpipes On Site Water Piping Sprinkler Heads Limited Area Other FEES lo~Q'~• FIRE DETECTION OR SUPPRESSION PERMIT PROCESSING FEE •uu LOW VOLTAGE PERMIT (DETECTION ONLY) $30.00 Minimum fee plus $20.00 each 1,000 sq ft or fraction thereof over 1,000 sq ft OUTSIDE PLAN REVIEW SERVICES (EXAMINER'S FEE AS CHARGED) 1 ~Q. STATE SURCHARGE (3%) TOTAL FEE DUE This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. This permit conveys no right to open any street, alley or sidewalk or any part thereof, nor to make any connection to a water main. t~ rJ~ Signature of Licensed Contractor ^w c c.! DATE w 07 FOR OFFICIAL USE ONLY Review Comments: -f n C f're irn lele7k-eb e s s ip, diva w eef AA-V 1i2 ow File e m A ov9/ X ~P Fire Department: a? C;$~ mile /Ylarsf,~., Dat 1111e A7 Plans Examiner: r Issued by CBO- Date: h e CITY QF 'DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Applications #07-201499 November 9, 2007 NONCONFORMANCE PLAN APPROVAL FIRE ALARM/DETECTION SYSTEM THIS IS NOT A BUILDING PERMIT. IT IS A RECORD OF OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT. Re: National City Bank Shell Building Improvements Applicant: Electric Power & Design, Partial First Floor & Second Floor Building Shell Areas (614) 781-5900 6680 Perimeter Drive Fire Protection Permit No: 07-201499 The Fire Alarm Documents dated 8/13/07, submitted with the Fire Protection Permit Application, for the captioned project, has been reviewed for compliance with the provisions of the 2007 Ohio Building Code (OBC). The review was based upon the following criteria: Use Group: B, Office Building. Occupancy: No Change Area: Existing Const. Type: No Change Notes: Proposed new fire alarm/detection system devices along with duct-mounted smoke detectors, to be located in the partial first floor and on the second floor Shell Building spaces. The Fire Alarm Drawings are signed and certified by Robert G. Sines III, Ohio Certification no. F-032. The fire protection contractor is Electric Power & Design, Certification #53-25-1573 and the Application identifies the fire alarm systems Installer as Timothy M. Novotni, Ohio State Certification Number 54-25-2186, all to comply with the requirements of OBC Section 105.3 and have been reviewed, therefore, in accord with OBC section 105.3.1.4. This NONCONFORMANCE PLAN APPROVAL is issued by the City of Dublin, Division of Building Standards, in accordance with Section 106.3.1.1 OBC. The building official may approve construction documents which do not conform with the requirements of the rules of the board when such nonconformance is not considered to result in serious hazard and the owner's representative subsequently submits revised construction documents showing evidence of compliance with the applicable rules. In the event such documents are not received within thirty days, the building official shall issue an adjudication order revoking the plan approval. (Emphasis Added) The final date for submission of revised documents with the following item(s) in full compliance with the OBC is November 27, 2007 as a condition of the issuance of this Plan Approval. Part I of this notice serves as a Correction Letter, allowing you to resubmit revised plans and/or additional information as noted. City of Dublin FIRE PROTECTION PLAN REVIEW 07-201499 National City Bank Shell Building Improvements - Fire Alarm / Detection System November 9, 2007 07-201499 Page 2 PART I. CORRECTION LETTER The following item(s) shall be brought into full conformance with the 2007 OBCprior to the issuance of final plan approval: 1. OBC 106.1.1 Information on construction documents. Because the construction documents do not have enough information for a complete plan review, this correction letter is a request for missing information and contains a review only of the items submitted. A complete review will be performed upon receipt of the required information. This may result in additional items not contained in this correction lett er; Section 106 OBC. Submit the following minimum information for review: 1.1 Please verify that manual alarm pull stations' are existing or will be placed within 5 feet of each entrance to the exits, in accordance with Section 907.3.1 OBC. These current Shell Building drawings did not locate any such devices on the Second Floor Plan. Please verify. For the information of the Applicant the following item(s) are required for code compliance, but are not necessarily covered in detail in the construction documents. This list & a reminder to the design professional and contractors of issues which are to be satisfactorily dealt with in the field: 2. The certificate of approval of fire protection plans shall be posted in a conspicuous location outside of the building or in the front part of the premises on which is, or will be, located the approved building or equipment. The owner and the contractor shall, so far as possible, preserve and keep said certificate until the completion of the work to which the approved construction documents relate; Section 105.7.2 OBC. 3. The proposed construction shall conform to the requirements of Chapter 1 I OBC and the "Americans with Disabilities Act Accessibility Guidelines" (ADAAG). 4. Provide a record of completion for each completed fire alarm system in accordance with Section 907.17 and NFPA 72 Completion Documents. 5. Upon completion of the fire protective signaling system, all alarm-initiating devices and circuits, alarm- indicating appliances and circuits, supervisory-signal initiating devices and circuits, signaling line circuits, and primary and secondary power supplies shall be subjected to a 100 percent acceptance test in accordance with NFPA 72A and 72E listed in Chapter 35; Section 907.16 OBC. 6. OBC 907 Acceptance testing: When the installation of the detectors is complete, each detector and all interconnecting wiring for multiple-station detectors shall be subject to a 100-percent acceptance test in accordance with the household fire warning equipment provisions of NFPA 72 listed in Chapter 35. 7. No electrical work (conduits, cables or other electrical apparatus) may be covered or concealed without visual inspection and approval by the electrical field inspector as per OBC 109. 8. All electrical work will comply with the requirements of Article 27 OBC and the National Electric Code NFPA 70, OBC approved edition and is subject to the approval of the electrical inspector, in accordance with Section 109 of the OBC. City of Dublin FIRE PROTECTION PLAN REVIEW 07-201499 f National City Bank Shell Building Improvements - Fire Alarm / Detection System November 9, 2007 07-201499 Page 3 TO REQUEST AN APPEAL HEARING, YOU MUST send a written request, listing the items to be appealed and the relief sought and on copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin, Ohio 5800 Shier Rings Road Dublin, Ohio 43017-1236 THE SIGNING OF THIS DOCUMENT IS AN AGREEMENT THAT YOU WILL COMPLY WITH ALL ITEMS LISTED HEREIN. THE COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF ALL ITEMS LISTED HEREIN. Reviewed and signed, ichael A. Boryca, Architect/Plans xaminer e e S er, Chief Building Official (61.4) 4009 City of ub 'n, Ohio i_ tatur - Architect, Engineer, Contractor Date or Owner Print Name and Title as Signed c: Washington Township Fire Department MAB:Iwb City of Dublin FIRE PROTECTION PLAN REVIEW 07-201499 CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00201499 Date 11/19/07 Property Address . . . . . . 6680 PERIMETER DR Parcel Number: 273-007303 Alternate Address: PERIMETER CENTER Tenant nbr, name . . . . . . NAT' CITY BANK DETECTION Application type description FIRE PROTECTION Application desc Nonconformance Approval Docs Req by 11/27/07 Property owner . . . . . . . TRIPLEX CO Contractor . . . . . . . . . ELECTRIC POWER AND DESIGN LLC Permit . . . . . . FIRE DETECTION PERMIT Additional desc NONCONFOR DOCS REQ BY 11/27/07 Permit Fee . . . . 60.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 60.00 Special Notes and Comments CONTACT WASHINGTON TOWNSHIP FIRE PREVENTION FOR INSPECTIONS AT 766-0857 Other Fees . . . . . . . . . OUTSIDE PLAN REVIEW 150.00 SURCHARGE FEE - BLDG 4.50 SURCHARGE FEE - FIRE 1.80 Fee summary Charged Paid Credited Due Permit Fee Total 60.00 .00 .00 60.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 156.30 .00 .00 156.30 Grand Total 216.30 .00 .00 216.30 i c This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. t architecture! memorandum invoice #07-201499 - 1 OHIO INCORPORATED 454 East Main Street Suite 236 Columbus, Ohio 43215-5380 614.488.4009 fax.488.4005 November 9, 2007 City of Dublin Contract No. PS 01-21-13 Employer Identification No. 31-1413248 City of Dublin Division of Building Standards 5800 Shier-Rings Road Dublin, Ohio 43016 Attention: Mr. Jeffrey S. Tyler, Chief Building Official Plan Review Services for: National City Bank Shell Building Improvements Fire alarm/Detection System 6680 Perimeter Drive, Partial First Floor & Full Second Floor NONCONFORMANCE PLAN APPROVAL Permit No. 07-201499 Labor Cost: Total Number of Hours to be Charged @ $60.00/Hour: 2.5 • Review Time: 1.5 • Administration Time: 1.0 TOTAL BILLING THIS INVOICE $150.00 This memorandum invoice is being sent as reference for you to prepare the necessary fees for the applicant to pay. The time spent on this review will be submitted for payment at the end of the month with our usual invoicing. Should you have any questions or comments concerning this review, please don't hesitate to contact me. Thank you for the opportunity to be of service. Cordially, architecture! t I Michael A. Boryca, Architect Plans Examiner 4P001794 /~J CITY OF DUBLIN DjvIsjon-.of auilding Standards • 5'800 Shier-Rings Road fT%PMV/ED P1 one: (614) 410-4670 • Inspection Line: (614) OCT 12 2007 WTFD: (614) 889-2347 } OCT 16 2007 ' tCi`1E~,~.Ott.lt0~ 1 FIRE PROTECTION PERMIT APPLICATI N w, r r Application Date I CST.' &7 Bldg. App. #61-W OO N Fire Protection App. # cy7 ;y ! qq PROJECT INFORMATION Project Address P { t Mefo( bv% Project Name ATIC 00- ( di4l A k Owner/Tenant Contact Name Q loll i n Telephone APPLICANT INFORMATION Fire Protection Contractor e_JV' C oweir and es i6 tit Address Z I Cg. 1-. Telephone M - S c(00 State Certificate Number - *LT- t Dublin Registration Number 09-6-7/9 Installer Name T%Mo v o+ h . State Certificate Number 54 - 25 1 18 to SCOPE OF WORK / (Mark One) New ? Replace Repair _ Alteration FIRE DETECTION AND ALARM SYSTEM (Number of Each) Detectors a Strobes Horns 2_ Fire Alarm Boxes Other 7. SUPPRESSION SYSTEM (Number of Each) Standpipes On Site Water Piping Sprinkler Heads Limited Area Other FEES FIRE DETECTION OR SUPPRESSION PERMIT PROCESSING FEE $50.00 LOW VOLTAGE PERMIT (DETECTION ONLY) $30.00 Minimum fee _ plus $20.00 each 1,000 sq ft or fraction thereof over 1,000 sq ft OUTSIDE PLAN REVIEW SERVICES (EXAMINER'S FEE AS CHARGED) STATE SURCHARGE (3%) TOTAL FEE DUE This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. This permit conveys no right to open any street, alley or sidewalk or any part thereof, nor to make any connection to a water main. Signature of Licensed Contractor Ord- _ DATE// &~o6v_ ?007 FOR OFFICIAL USE ONLY Review Comments: Fire Department: Date: Plans Examiner: Date: !l• / 2.07 Issued by CBO: Date: r COOPER Wheelock Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories Description: Designed for life safety, performance and reliability, Cooper When used in conjunction with Wheelock PS-24-8MC Power Wheeloc k's cost effective weatherpoof notification appliances Supplies or SM/DSM Sync Modules, the Wheelock weatherproof include: appliances can be synchronized to meet NFPA 72 synchronization Weatherproof Appliances Series requirements. The horn output of hom strobes can be independently controlled on 2 -wire circuits using the Wheelock patented sync Strobes RSSWP protocol. MTWP horn strobe models are 4-wire appliances; the Hom Strobes ASWP strobes can be synchronized while the audible can be connected Homs AH-24WP, AH-12WP to a coded fire alarm system or can be set to produce any of eight Multitone Hom Strobes MTWP selectable tones. Multittone Homs MT Speaker Strobes ET70WP Speakers ET 1010 Features: All strobe models are UL dual listed - meeting both UL1638 Approvals include: UL Standards 1971, 1638, 464 and 1480 and UL1971 requirements. As dual listed appliances, these Fire Marshal (CSFM) and New York City weatherproof strobes, horn strobes and speaker strobes are Wed California California State , Factory Mutual (FM) and Chicago New Y See for outdoor applications under UL 1638 as well as under UL 1971, (MEA the Standard for Safety Signaling Devices for Hearing Impaired. agency approvals by model number on page two of this With an extended temperature range of -31°F to 150°F (-40°C document to 66°C), Wheelock weatherproof appliances meet or exceed UL Compliance with the following requirements: NFPA, UFC, outdoor test requirements for rain, humidity and corrosion resistance ANSI 117. 1, OSHA Part 29, 1910.165, ADA while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 Weatherproof with extended temperature range of ~0°F to strobe spacing tables (up to 185 candela for wall mounting and 177 150°F (-40°C to 66°C)' candela for ceiling mounting). Dual Listed strobe models (UL 1638 and UL 1971) To enable weatherproof mounting, Cooper-Wheelock provides the Industry's highest strobe candela options industry's widest choice of mounting options for surface or unique sem"ush installation. Models are available for surface mounting Synchronization capability using Series SM, DSM Synch to Wheelock weatherproof badkboxes on walls or ceikngs. The Modules (MTWP and MT 12/24 audible is non-sync) optional WP-KIT allows the weatherproof badkboxes (1013, WPBB or Models with field selectable tone, dBA and candela settings WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA and Wall or ceiling mounting options WFPA kits allow a customer to mount the weatherproof appliances Surface of semOush mounting to a recessed electrical box without the need for an external IN/OUT wiring termination accepting two #12-18 AWG wires weatherproof badkbox. See the Badkboxes, Plates and Gaskets at each terminal Table on page three of this document for a summarization of these mounting options and the required accessories. 'The series RSSWP, ASM, MTWP and ETMAP have UL approval down to 4WF. The AH-24M, MT-12/24 and the ET-1 010 have been ULC tested and approved to -40T, but not submitted to UL. The AH-12WP has UUULC approval to -31 T. <A~P@PM> ®L MEA ESM 151-92-E 7125-0785:131 (ASWP) 55391 7125-0785:146 MT70WP) S2652 7125-0785:156 (MTVHP) 7300-0785:154 (RSSWP) 1 NOTE: AM CAUTIONS and WAPJANGS are identified by the symbol A. AM wamings are prfuted In bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT W W W.000PERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS. CAUTIONS OR WARNINGS COULD RESULT IN MINItOPER APPLICATION, INKMLLATION ANWOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION. V*§CH COULD RESULT IN PROPERTY DAtrAGE. AND SERIOUS PLA1RY OR DEATH TO YOU AND/OR OTHERS. General Motes: • Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. • AN candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Wail Mount Ceiling Mount Wall or Ceiling Mount RSSWP MTw RSSWP ~MTWP MT AH ' ASWP ET70WP ASWP ET70WP ET 7070 Strobe Order Code Strobe Order Code Audible Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475C-FR Red 4338 AH-24WP-R Red 7416 RSSWP-2475W-FW White 3034 RSSWP-2475C-FW White 4446 AH-12WP-R Red 7415 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCCH-FR Red 5167 RSSWP-24MCVVH-FW White 5165 RSSWP-24MCC14-FWWhite 5187 Horn Audible Strobe Audible Strobe MT-12124-R Red 5023 ASWP-2475W-FR Red 9012 ASWP-24750-FR Red 4251 Speaker ASWP-24MCHW-FR Red 5137 ASWP-2475C-FW White 4502 ET-1010-R Red 3135 ASIAP-24MCWH-FW Mite 5140 ASWP-24MCCH-FR Red 5149 ET-1010-W White 3137 Multi-tone Strobe ASWP-24MCCH-FW White 5157 MTWP-2475W-FR Red 8420 Multi-tone Strobe L Max. Current AH MTWP-2475W-FW White 3112 MTWP-2475C-FR Red 4457 24 VDC 12 VDC MTWP-24MCVVH-FR Red 5132 MTWP-24750-FW White 4478 igh (99) dBA 0.080 0192 MTWP-24MCWH-FW White 5134 MTWP-24MCCH-FR Red 5102 Oed (95) dBA 0.043 0.108 Speaker Strobe MTWP-24MCCH-FW White 5122 ow (90) dBA 0.021 0.058 ET70WP-2475W-FR Red 9077 Speaker Strobe ET70WP-2475W•FW White 3179 ET70WP-2475C-FR Red 4452 E-t,OWP Reverberant dBA Q 10 Feet ET70WP-24185W-FR Red 4885 ET70WP-24750-FW White 4454 s 118 1/4 1/2 1 2 4 8 ET70WP-24185W-FW White 4891 ET70VVP-24177C-FR Red 4845 ET70WP-24177C-FW White 4859 010 77 80 83 86 87 92 94 78 81 84 87 190193 95 Candela Ratings UL 1971 UL 1638 UL 1638 RSS, ET70MF and ASWP Series a 32°- @ 77"F a -40-F MTWP UL Max Current h Med Low Model Number A vats 120OF Strobe On g Agency Approvals 30 180 115 0.138 0.168 0.155 0.150 135 135 65 0.300 0.355 0.340 0.335 Strobe UL MEA CSFM FM BFP MCWH RSSWP-2475 X X X X 185 185 90 0.420 0.480 0.465 0.460 RSSWP-24MCWH X 115 115 50 0.300 0.355 0.340 0.335 RSSWP-24MCCH X * MCCH Audible Strobe 177 177 75 0.420 0.480 0.465 0.460 24185 185 185 90 0.420 ASWP-2475 X X X X X ASWP-MCWH X * 24177 177 177 75 0.420 ASW1P-MCCH X * Multitone Strobe MTWP-2475 X X X X L Max. Current MTWP/MT MT MTWP-MCWH X Audfe) 24 VDC 12 VDC MTWP-MCCH X * BA HI STD HI STD HornslAudibles om 0.108 0.044 0.177 0.034 AH-24WP X X X - X 30 0.053 0.024 0.095 0.020 AH 12WP X X X - X arch Time 0.104 0.038 0.142 0.034 MT-12124 X X X X X 11 ode 3 Horn 0.091 0.035 0.142 0.034 Speaker Strobe ode 3 Tone 0.075 0.035 0.105 0.021 ET70WP-2475 X X X ow Whoop 0.098 0.037 0.142 0.035 ET70WP-185 X iren 0.104 0.036 0.152 0.030 ET70WP-177 X i/Lo 0.057 0.025 0.114 0.026 *Pending t Mounting Accessories [10 WFP WFPA IOB WPSBB WPBB WBB Gasket Kit Order Code WP-KIT 4486 Mounting Options: Backboxes, Plates, Gasket Kits Flush Plates WFPA-R Red 4698 Surface Mount Flush WFPA-W White 4701 Exposed Conduit Concealed Conduit Mount WFP-R Red 4696 WFP-W White 4697 RSSWP Strobes WPSBB WPSBB + WP-KIT WFP Backboxes ET70WP Speaker Strobes 106 1013 + WP-KIT WFP 1013-11 Red 5046 ASWP Hom Strobes WPBS WPBB + WP-KIT WFPA IOB-W White 5047 WPSBB-R Red 9751 AHWP Horns WBB - WFP WPSBB-W White 3033 ET-1010 Speakers WBB - WFP WPBB-R Red 9014 WPBB-W White 4692 MTWP Multitone Horn Strobes IOB 1013 + WP-KIT WFP WBB-R Red 2959 Multitone Horn IOB 1013 + WP-KIT WFP WBB-W White 2960 SERIES MTWP APPLIANCES SYNCHRONIZED STROBE Wiring Diagrams OPERATION WITH CODED FACP MT*r 0 -0 Saoee e 0 c1~cuR -0 sync W SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE NAC 01 Module IN UNISON. RED AND BLACK SHUNT WIRES ARE SUPPLIED., Auawla 0 CkMA Power FROM TO NEXT FACP Supply RECEDING + + APPLIANCE PPLIANCE RED - - OR EOLR NAC r2 R FACP BLACK Note: Strobe circuit requires constant voltage. SERIES RSSWPIASWP APPLIANCES SYNCHRONIZED W1 + DSM MODULE SINGLE CLASS "A" MAC CIRCUIT STROBE AUDIBLE DSM STROM 0 SERIES RSSWP, ASWP, AHWP, MTWP AND MT-12124 CUITH "A~ S 0 APPLIANCES 0 arts +o , FROM + + TO NEXT 0+1N,® ~ Rsw PRECEDING APPLIANCE us IN APPLIANCE OR OR EOLR FACP +AMBLER FACP MINUS 20 -0+1N A R5% R5w -STROBEN o- + - NA® +OUT 7® CIRCUITS RETURNS Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. *Refer to Data Sheet 37000 for Mounting Options NOTE: Due to continuous devehWnent of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. ARCFI/TECTS AND ENGINEERS SPECIFICATIONS General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof badcboxes using either exposed conduit or concealed conduit, or semi flush mounting to a recessed electrical box in waft or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of -40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof homs and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The homs shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. To Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Muititone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be fisted for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET 1010. They shalt be listed to produce up to 94 dBA and shall incorporate a vandal resistant grime design. Speaker with strobes shall be Wheelock Series ET70WP. They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS-24-8MC Power Supply with built-in, patented sync protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock IOB, WBB, WPBB or WPSBB weatherproof bac kboxes using either exposed conduit or concealed conduit For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. 1NNiYrM 273 Branchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732) 222-2588 3 YEAR WARRANTY www.cooperwheelock.com Made in USA S9004 WP 03107 }3®&a M m~q Qj( TrueAlerf* Multi-Candela Notification Appliances UL, ULC, CSFM Listed, FM Approved, SmartSyneTM Operation Audible/ iSibItte MEA (NYC) Acceptance* with Hom and Synchronized Flash, Non-Addre :Sabi:. OPIUM Audiblelvisible (AIV) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount • Operation is compatible with ADA requirements (refer to important installation information on page 3) • Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens # Operates over a two-wire SmartSync circuit to provide: • Horns that are controlled separately from strobes on the same two-wire circuit / • "On-until-silenced" and "on-until-reset" operation on the same two-wire pair M • SmartSync horn activation of Temporal pattern, March _ Time pattern (at 60 BPM), or on continuously • Strobe appliances on the same circuit operating at a / synchronized 1 Hz flash rate • Class B (Style Y) operation requires connection to a Wall and Ceiling Mount ANs compatible SmartSync NAC or to SmartSync Control Module (SCM) 4905-9938 9 - • • • Class A (Style Z) operation when connected to the Multi-Candela TrueAlert AIVs with horn and 4905-9938 SCM or with 410OU series fire alarm control synchronized strobe provide convenient installation panel NACs to standard electrical boxes. The enclosure designs are Wall mount A/Vs features: both impact and vandal resistant and provide a convenient • Wiring terminals are accessible from the front of the strobe intensity selection. Since each model can be housing providing easy access for installation, selected for strobe intensity output, on-site model inspection, and testing inventory is minimized and changes encountered during • Covers are available separately to convert housing color construction can be easily accommodated. Wall mount AN housings are a one-piece assembly Optional adapters and wire guards: (including lens) that mounts to a single or double gang, or • Wall mount AN adapters are available to cover surface 4" square standard electrical box. The cover can be mounted electrical boxes and to adapt to Simplex'* quickly removed (a tool is required) and covers are 2975-9145 boxes available separately for color conversion. • UL listed red wire guards are available for wail or ding mount ANs install using standard 4" electrical ceiling mount AIVs boxes. Color choice is determined by model number. Visible notification appliance (strobe): • • . • • 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured During installation, a selection plug at the bank of the behind strobe housing housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow • UL listed to Standard 1971 background allows the selected intensity to be seen at the • Regulated circuit design ensures consistent flash output side of the strobe lens. and provides controlled inrush current The; P'odW has been WPU*d W ere CaMMM Stale FV8 LINS 1(CSFu1 WSW e Audible notification appliance (hom): SeCtIM 7125M" i for Amble vakles moo UffEV I Wmartad in this • Low current, 24 VDC electronic horn with harmonically, da 1. It s suds b reeaaaiaatiai, ref GM and poWAte Meelatim. Aooepied for use - Clty of bier Yak ©eparknett d Buifts- IEA35-9K. Raft b page 2 for is*V rich sound output suitable for either steady or coded stakes of •,ke guards. adMonai Wings may be appicabk wnW your beat Skr x operation (Temporal or 60 BPM March Time pattern) prod" a % "*W for the West sus LftW and WMM maw Sopm TOR ReF Co. m die pmpenr at Tyco safely Pmducls fir. • UL listed to Standard 464 " Swou muwcardeta smar?Syrc bwate Wffftobe appir- aperaY 1 is poYeched under one or more of ft broa.rg U.S. Patent t4umb m 5,559,492-,5,622,427,, 5,86&527; 5,886.&20: 6,281,789; 6,%4,137:7,W5,971; and 7.006,003. S4.90F3.4 002-3 Wfft Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy, location, local codes, and proper applications provide the ability to activate both the horn and strobe on of. the National Fire Alarm Code (NFPA 72), ANSI the same NAC and then allow the horn to be silenced A117.1; the appropriate model building code: BOCA, while the strobe remains flashing. The horn operates as ICBO, or SBCCI; and the application guidelines of the "on-until-silenced" while the strobe operation is Americans with Disabilities Act (ADA). "on-until-reset." • - Multiple Strobes. When multiple strobes and their • 4006, 4008, 41000, and 4010 Fire Alarm Control reflections can be seen from one location, synchronized Panels (refer to individual product data sheets for more flashes reduce the probability of photo-sensitive reactions information) as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender (refer to data sheet random flashing. The multi-candela strobes of these ANs S4009-0002) are synchronized by the controlling SmartSync operation . SmartSync Control Module (SCM) 4905-9938 (refer to NAC. data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. • • • • Multi-Candela ANs Model Mounting Housing Color "FIRE" Lettering Description 4906-9127 Wall Red White 4906-9129 White Red Horn with Muni Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two-wire 4906-9128 Ceiling Red White control 4906-9130 White Red Wall Mount AN Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep 5-3/8" H x 5-1/4" W x 1-5/8" D surface mounted boxes (136 mm x 133 mm x 41 mm) 4905-9940 White depth with strobe = 4-3/8' (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16"x 5-3/4"x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8!'x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8"x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount ANs Model Description Dimensions 4905-9994 Red cover with white "FIRE" lettering 5-1/8" H x 5" W x 1-1/2" D 4905-9995 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimensions 4905-9961* Wall mount red wire guard with mounting plate, compatible with semi-flush 6-1/16" H x 6-1/16" W x 3-1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2" x 6-1/8" x 3" (216 mm x 156 mm x 76 mm) 4905-9928* Ceiling Red Adapter Plate, required to mount guard to surface 9"x 7' Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 4-3/4" x 6-7/8" x 1-112" deep, 4905-9916 Red 1-1/2' deep surface mounted boxes (121 mm x 175 mm x 38 mm) * UL listed by Space Age Electronics Inc. 2 S4906-0002-3 6/2006 Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 DC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm) ; two wires per Connections terminal for iNout wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Horn Output Voltage 16 VDC 24 VDC 33 VDC Ratings Sound Type (see Note 2) Steady Coded Steady Coded Steady Coded 10 ft (3 m) UL 464 Reverberant Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA (see Note 2) Antechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5-1/8'H x 5"W x 2-3/4"D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd wall Strobe Setting (see Note 3 below) 75 mA 116 mA 221 mA 285 mA Mount Reference RMS Currents 18 VDC 70 mA 101 mA 184 mA 243 mA at other voltages 24 VDC 60 mA 84 mA 143 mA 185 mA Housing Dimensions (with lens) 4-3/4 L" x 6-7/8"W x 2-5/8"D (121 mm x 175 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting (see Note 3 below) 86 mA 132 mA 250 mA 320 mA Mount Reference RMS Currents 18 VDC 81 mA 119 mA 216 mA 283 mA at other voltages 24 VDC 70 mA 97 mA 167 mA 217 mA NOTES: 1. "Regulated 24 DC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. 3. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) 0 0 Mounting is compatible with (1 0 1 r IMPORTANTI WALL MOUNT single gang, double gang, and a" (102 mm) square boxes, = - - INSTALLATION HEIGHT REFERENCE 1-1/2" (38 mm) deep, by others o 0 0 Bottom of lens is either even with, or slightly Electrical box outline • o o i above bottom Wiring access hole O of compatible boxes Wiring terminals for ° SmariSync operation " " Holes: 4" squag (4) NFPA 72 requires 80" (2.03 m) Single e gang (2) that the entire lens minimum a..v.o..a Single Double gang (3) be not less than 80" and not greater than 96" above the Transparent housing finished floor and lens assembly Intensity selection plug, accessible only from rear of housing; 15 n E factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0002-3 6/2006 a 2U u• • • Ceiling reference, 4" (102 mm) square box, Optional 4905-9928 Adapter Plate, surface mounted box 1-1r2"(38 mm) minimum depth required for surface mounted electrical box Four mounting damps included, two each side C::n 0 eiling reference, flush mounted box Optional 4905-99151-9916 Adapter, recommended for surface mounted box Wring terminals are Optional 4905-9927 Red Wire Guard located behind the housing End View Strobe intensity viewing slot t Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt ° and Optional Wire Guard 1 56:9 Surface mount conduit and O box shown for reference 4"(102 mm) square , box profile, 1-1/2" O U (38 mm) deep 1111409 Optional O O 4905-9961 ~ Wire Guard AN o 9RE 49059931 Adapter Plate Optional Surface Mount Adapter Skirt, O 49059961 Optional Wire Guard 1-1/2" deep: 4905-9937, Red; (shown here for reference only, 4905-9940, White (conduit knockouts 49059931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyty Stm p x. dw Smoec kWtk JLWet. TrwAlat, awd S awtSym are truAvu its of Tytw hM¢rnaeaxnf AU or its opelmoes in the US andar other eoamrtes. NFPA 72 and Nairmal Fhr Alarm Code are registered tetad mw*; yf dre Nark wad Fire Ptvteehas Axraccwom (NFPAi 9 Tyco Safety Products Wedminsler - WedmOmter, MA • 01441-0001 • USA S4906-0002-3 6/2006 w ww tycosafetyproducts-usa-wri.com V)20057.WoN*ivProdwis Wesimmsier.ANrightsreaerwdANspw#6caflorwwWoAara0 nw ftm&%awnwarcrremasL4ducwwntn- =mdwmalare3u*vttoL*OWwiNiowtr> v ON- Multi-Application Peripherals UL, ULC, CSFM Listed, FM Approved, IDNetTm or MAPNET II® Communicating Devices MEA (NYC) Acceptance' Addressable Manual Stations OCR= Individually addressable manual fire alarm ~t stations with: • Power and data supplied via iDNet or MAPNET 11 addressable communications using a single wire pair** • Operation that complies with ADA requirements • Pull lever that protrudes when alarmed • Break-rod supplied (use is optional) • Models are available with single or double action (breakglass or push) operation 4099-9001 Addressable Manual Station • UL listed to Standard 38 (front and side view) Compatible with the following Simpleio control panels: • Model Series 4008, 4010, 4100U, 4020, 4100, and 4120 fire alarm control panels equipped with either IDNet or MAPNET II communications • Model Series 2120 Communicating Device Transponders (CDTs) equipped with MAPNET III communications t__J Compact construction: 4099-9002 4099-9003 With 2099-9828 • Electronics module enclosure minimizes dust Breakglass Push Institutional infiltration Cover kit • Allows mounting in standard electrical boxes • • Screw terminals for wiring connections Activation of the Simplex 4099-9001 single manual station requires a firm downward pull to activate the Tamper resistant reset key lock (keyed same as alarm switch. Completing the action breaks an internal Simplex fire alarm cabinets) plastic break-rod (visible below the pull lever, use is Multiple mounting options: optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull • Surface or semi-flush with standard boxes or requirements needed for easy activation. The pull lever matching Simplex boxes latches into the alarm position and remains extended out • Flush mount adapter kit of the housing to provide a visible indication. • Adapters are available for retrofitting to commonly Double Action Stations (Breakglass) require the available existing boxes operator to strike the front mounted hammer to break the 197-1aff-111011 glass and expose the recessed pull lever. The pull lever then operates as a single action station. The Simplex model 4099-9001 addressable station Double Action Stations (Push Type) require that a combines the familiar Simplex manual station housing spring loaded interference plate (marked PUSH) be with a compact communication module that is easily pushed back to access the pull lever of the single action installed to satisfy demanding applications. Its integral station. individual addressable module (IAM) constantly monitors status and communicates changes to the connected control Station reset requires the use of a key to reset the panel via IDNet or MAPNET li communications wiring. manual station lever and deactivate the alarm switch. (If the break-rod is used, it must be replaced.) ' Refer to page 2 far spea7c model fangs TW aoduct rm been appmved by the Station testing is performed by physical activation of Cafarea Stale Fim Umshal (CWel pu wwd to Secdon 13144.1 of the Cam Haab the pull lever. Electrical testing can be also performed by and safety Cade. See CSFU Lis" 7150-0026224 for Aowable Y*m arxtlor m4ftm wmwdm material pteseMed in fisdomwent b i& Wbpct b te-mtama0on, Terris W unlocking the station housing to activate the alarm switch. and possiblD caxaWon. Awed for use - City of Now Yark Oepa VnW of Ei Akgs - t~A35~g3E. Adtbl RW be apple' cantt your bcA S"n¢!ex pn~duct " IF t and MAPNET !I ddr -wabie communiratinn. esttdns are proiec;er 4y',' tar the latest St> m L am appraraks tinder Simplex Time ReacmJer Co am properly of Tyco Safety Pwducls wesbrstar. Pa No. 4,796,025; 5,088,002; and 8,034,80?. S4099-"1-7 5!2006 Fire waM--imiTi-- Addressable Manual Stations, Red Housing with White Letters and White Pull Lever Model Description Housing Pull Lever Listings 4099-9001 Single action, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM, MEA 4099-9001 CB Single action, Bilingual English and French FEU FIRE TIREZ PULL ULC, FM 4099-9001CF Single action, French ALARME FEU ABAISSEZ 4099-9002 Double action, Breakglass operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM, MEA 4099-9003 Double action, Push operation, English Accessories Model Description 2975-9178 Surface mount steel box, red Refer to page 3 for dimensions 2975-9022 Cast aluminum surface mount box, red 2099-9813 Semi-flush trim plate for double gang switch box, red Typically for retrofit, refer to page 4 2099-9814 Surface trim plate for Wiremold box V5744-2, red 2099-9819 Flush mount adapter kit, black Refer to page 4 for details 2099-9820 Flush mount adapter kit, beige 2099-9803 Replacement breakglass 2099-9804 Replacement break-rod 2099-9828 Institutional cover kit for field installation on 4099-9001 Power and Communications IDNet or MAPNET 11 communications, 1 address per station Address Means Dipswitch, 8 position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire UL Listed Temperature Range 32" to 120° F (0" to 49" C) intended for indoor operation Humidity Range Up to 93% RH at 100" F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan® poycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions .5"H x 3-3/4"W x 1"D (127 mm x 95 mm x 25 mm) • • Single Gang Box MouM 4" Squaile Box Mount Single gang box, 2-1/Y deep r (102 mm) square bw 2-118" (54 mm) min (64 mm), RACO #500 or equal depth, RACO #231 or equal (supplied by others) (supplied by others) 0 0 Mount flush or with 4A 6V rJ 1/16"(2 mm) C maximum extension 4" Square box C 0 rJ oo NOT RECESS with cover plate Station ; FIRE ®ALARM side view Single gang cover plate, 3/4" (19 mm) extension, RACO #773 PULL DOWN or equal (supplied by others) l Single gang box outline Wall surface Semi-Flush Mount Side View LSStrrtple~rl, 2 S4099-0001-7 5/2006 MWEI&ETO • IM 11 • MflM 2976-8178 Box 2976-9022 Cast Box Preferred Mounting. For 5-3/16" H x 4"W x 2-3/16" D 5" H x 3-7/8" w x 2-3/16" D surface mounting of these (132 mm x 102 mm x 56 mm) (127 mm x 98 mm x 56 mm) (ordered separately) (ordered separately) addressable manual stations, the preferred electrical boxes are shown in the illustration to the 0 0 0 0 right. Additional Mounting Knockouts located Reference. Refer to page 4 for top and bottom Wiremold box mounting compatibility. FIRE ®ALARM 0 0 PULL DOWN ,r Access for 314" threaded S' conduit located top and bottom (127 mm) 69mplex 1" (25.4 mm) (.---3-3/4" (95 mm)--~ 4099 Series Addressable Manual Station Refer to NFPA 72, the National Fire Alarm Code, and all applicable local codes for complete requirements for (32 mm) Simplex 2975-9178 box manual stations. The following Field wiring (shown for reference) (shown for reference) summarizes the basic requirements. 1. Stations shall be located in the normal path of exit and distributed in the protected area such that they Address setting under are unobstructed and readily resealable label (accessible accessible. with cover open) 2 5/8" 2. Mounting shall be with the (67 mm) operable part not less than 3-1/2 ft (I. I m) and not more than 4-1/2 R Station cover (1.37 m) above floor level. hinges open for 3. At least one station shall be installation access provided on each floor. Additional Switch wiring stations shall be provided to obtain (prewired) a travel distance not more than 200 ft (61 m) to the nearest station from any point in the building. 4. When manual station coverage appears limited in any way, additional stations should be installed. 3 S4099-0001-7 5/2006 For retrofit and new installations, additional 0 0 Wiremold compatible mounting boxes If= C=E)f receptacle box and the required adapter plates 2099.9814 Surface trim model V5744-2 Memo are shown in the illustration to for /8" H kt box (supplied by 5-11/8" H x 5" W others) the right. (130 mm x 127 mm) IL O o ZC==, !~r3" T o gang switch box, each " H x 2" W x 2-3/4" D (76 mm x 51 mm x 70 mm) (supplied by others) 4099-90011DNet addressable station O® 2099-9813 Semi-flush trim for 2 gang O 9 E!--) o switch box, 6" H x 4-1/2" W (152 mm x 114 mm) Flush mount adapter kit 2099-9819, Black 2099-9820, Beige ~ - Box must be recessed into wall 1" to 1-1/8" (25.4 mm to 29 mm) ~•3 r C 8" O (203 mm) Hoye cutout must be a minimum of 6" H by 5" W O 6- 152 mm by 127 mm) (152 mm) O l_ 4-11/16" (119 mm) square box, 2-1/8" (54 mm) minimum Wall depth (by others) 4-3/4"(121 mm) surface 6-3/4"(171 mm) Front View Side View Tyco, Simplex, the Simplex logo, MAPN6T 17, and IDNet are trademarks of Tyco International Services AG or its affiliates in the U.S. and'or other countries. NF'PA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Lexan is a trademark of the General Electric Co. Wiremold is a trademark ofthe Wiremold Company. Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA 54099-0001-7 512006 Q. mplex www.tycosafetyproducts-usa-wm.com cc, 2006 Two Safety Products Westminster. All rights reserved All specifications and other information shown were current as afdocument revision date and are subject to change without notice. G®Sjmplex TrueAlarm Analog Sensing UL, ULC, CSFM Listed, FM Approved,- Addressable Duct Sensor Housings with TrueAiarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control Compact air duct sensor housing with clear cover to monitor for the presence of smoke** GOOD= ~ Includes factory installed TrueAlarm photoelectric smoke sensor and features: a0~ • Individual sensor information processed by the host a o control panel to determine sensor status o Y • Digital transmission of analog sensor values via IDNetTM or MAPNET II0, 2-wire communicationst • Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and o monitoring of sensor dirt accumulation Model 4098-9755: • Basic duct sensor housing (no relay output) powered by IDNet/MAPNET Il communications Duct Sensor Housing, Front and Bottom View Model 4098-9756: • Duct sensor housing with supervised output for e multiple remote relays; requires separate 24 VDC; o ° includes one relay • Relay output is under panel control a • At the panel, relay output can be activated manually or in response to a separate alarm or other input 2098-9808 2098-9806 General features: Remote Status/Alarm Indicator and Test Station • UL listed to Standard 268A i. • M. • Clear cover allows visual inspection Operation. Simplexe compact air duct smoke sensor • Test ports provide functional smoke testing access housings provide TrueAlarm operation for the detection of with cover in place smoke in air conditioning or ventilating ducts. Sampling • Mounts to rectangular ducts or round ducts; minimum tubes are installed into the duct allowing air to be directed to size is 8" (203 mm) square or 18" (457 mm) diameter the smoke sensor mounted in the housing. • Magnetic test feature for alarm initiation at housing • • • • • • Optional weatherproof enclosure is available Digital Communication of Analog Sensing. separately (refer to data sheet S4098-0032) Analog information from the sensor is digitally Diagnostic LEDs (on interface board): communicated to the control panel where it is analyzed. • Red Alarm/Trouble LED for sensor status and Sensor input is stored and tracked as an average value communications polling display with an alarm or abnormal condition being determined by • Yellow LED for open or shorted trouble indication of comparing the sensor's present value against its average. supervised relay control (4098-9756 only) Intelligent Data Evaluation. Monitoring each Sampling tubes (ordered separately): photoelectric sensor's average value provides a software filtering process that compensates • Available in multiple lengths to match duct size factors for environmental (dust, dirt, etc.) and component aging, providing • Installed and serviced with housing in place an accurate reference for evaluating new activity. The Remote module options (ordered separately): result is a significant reduction in the probability of false • Remote red status/alarm LED (2098-9808) or nuisance alarms caused by shifts in sensitivity, either up or down. • Remote test station with LED (2098-9806) - Please note that smoke detection in air ducts is intended to provide • 4098-9843 remote relays (refer to page 2 for details) nofificafion of the presence of smoke in the duct. It is not intended ' These products have been approved by the Calibrw State Fire Marshal (CSFM) pursuant to to, and will not, replace smoke detection requirements for open Section 13144.1 of the California Health and Safety Code. See CSFM Listing 32400026.241 areas or other non-duct applications. for allowable values and/or cordfllmu conoernN material presented in this document. It is subject to wexamkraion, revision, and possible cancellabon. Accepted for use - City of New T TrueAlarm sensors and IDNet and MAPNET II communications are protected by one or York Department of Bulldk* - MEA35-93E. Additional istinp may be appicable; contact more of the folbvkg U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5,400,014; your local Skeplex product supplier for the latest stalus. Ltstings and approvals under Simplex 5,543,777; 5,710,541; D383,407; D388,352; D392,573; 4,796,025. Time Recorder Co. are the property of Tyco Safety Products Weshr infer. S4098-0030-5 3/2007 • Control Panel Selection. Peak activity per sensor is Typically duct sensor applications require less sensitive stored to assist in evaluating specific locations. The alarm settings (such as 2.5% per foot obscuration) due to the set point for each sensor is determined at the control ducts being a relative dirty environment. However, the panel, selectable as the individual application requires. standard seven levels of TrueAlarm sensor sensitivity are Sensor Status LED. Each sensor housing's red status available for each individual sensor, ranging from 0.2% to LED (located on the electrical interface board) pulses to 3.7 /o per foot of smoke obscuration. Sensitivity is indicate communications with the panel. If the control selected and monitored at the fire alarm control panel. panel determines that a sensor is in alarm, or that it is - • • dirty or has some other type of trouble, the details are - annunciated at the control panel and that sensor housing's • Individual smoke sensitivity selection status LED will be turned on steadily. During a system • Sensitivity monitoring that satisfies NFPA 72 alarm, the control panel will control the LEDs such that sensitivity testing requirements an LED indicating a trouble will return to pulsing to help . Peak value logging allows accurate analysis for identify any alarmed sensors. (Remote Status/Alarm sensitivity selection LEDs track the operation of the sensor housing LED.) • Automatic, once per minute individual sensor • • - m• calibration check verifies sensor integrity • Automatic environmental compensation TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode • Smoke sensitivity is displayed in percent per foot receiver to provide consistent and accurate low power • Ability to display and print detailed sensor smoke sensing. information in plain English language • Relays of model 4098-9756 are under panel control • for ON, OFF, or override Duct Smoke Sensor Housing with Photoelectric Sensor' Model Description Compatibility Basic Duct Sensor Housing; operating power is supplied by Simplex fire alarm control panel models 4010, 4098-9755 either IDNet or MAPNET II communications (no relay output) 4020, 4100,4100U, and 4120. Also 2120 CDT if configured for MAPNET 11, TrueAlarm operation Duct Sensor Housing with supervised multiple relay output, Same as above except relay operation is not 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 compatible with 2120 CDT; end-of-fine resistor harness; includes one 4098-9843 relay Relay output is for up to 15 total 4098-9843 Relays (additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required Model Description Compatibility Mounting 2098-9808 Red LED status indicator 4098 Use single gang box, -9755 2098-9806 Test Station with keyswitch and red LED status indicator 4098-9756 3° H x 2"W x 2" D (turning switch to "TEST" initiates alarm for system testing) (76 mm x 51 mm x 51 mm) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Compatibility Location Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 Locate relays within 3 ft 4098-9843 for additional relay information; one included with 4098-9756; 4098-9756 only; (1 m) of device being wiring is 18 AWG (0.82 mm2) color coded wire leads conned up to 15 controlled per NFPA 72 End-of-Line Resistor Harness; 10 W, 112 W, (ref. 733-894); 4081-9008 required to supervise remote relay coil connection 4098-9756 At last relay location • Each dud housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Overall Duct Width Tube Required Suggested Cut Length 12" (305 mm) 2098-9796 1/2" (12.7 mm) longer than duct width 13" to 23" (330 mm to 584 mm) 2098-9804 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 2098-9797 2" (51 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 2098-9798 2" (51 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 2098-9799 2" (51 mm) longer than duct width 2 54098-0030-5 3/2007 • • • i- NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information. 11-3/8" (289 mm) Exhaust to access hole onduit b others 4098-9714 Smoke sensor, mounted • x in speaaI interface base (supplied) Metal plate with dual holes • - - for 3/4" (19 nun) conduit, plug supplied for unused hole 0 000001 .O 6-3/4" I • (171 mm) 0 0 000 it 0 0 00 Yellow LED, relay control trouble Sampling tube 0 _ indicator (4098-9756 only) access hole • 0 0 0 Red sensor 0~ status LED Side of duct 0 x • O ° O Wiring terminals Stationary baffle (buiR-in) Captive fastening screws (4) (Magnetic test area Mount as shown (preferred) or Transparent cover Gasketed sensor area with electronics area located to the LEFT or UP ONLY 3 3/8" (86 mm) • • O®~ 13/16" Gaskets (supplied) -Ay (21 mm) Dud wall Exhaust tube (supplied) Test ports (2) provided Sampling tube, ordered for measuring airflow separately per dud width [and for aerosol injection End View with Duct and Tubes Dud housing 18" Round dud outline 4098-9843 Remote Relay (minimum diameter) (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within - - - - - - - - - I 3 ft (1 m) of device being controlled per 1 NFPA 72 8" Square dud outline Exhaust be (minimum width) 1 13/16" 1 (21 mm) 1 1/2" Sampling tube, keyed for proper hole alignment (38 mm) 1-3/16" (30 mm) with holes facing into airflow (template is provided for proper tube installation) 3 S4098-0030-5 3/2007 • . . Preferred Duct Sensor Locations: 1. A minimum of six duct widths downstream from Exhaust Sensor bends or inlets to avoid air turbulence. ,l Damper O2. On the downstream side of filters to detect fires in the Exhaust f -Return filters. Air 3. In return ducts, ahead of mixing areas. Do not locate 4. Upstream of air humidifier and cooling coil. sensor here 5. With accessibility for test and service. Gamper 6. For additional information, refer to NFPA 90A, R~ Standard for the Installation of Air Conditioning and Ventilating Systems. Fresh --?Supply airs Air Locations to Avoid: r r Sensor 1. Where dampers closed for comfort control would senotnsor here locate Fbanki OK interfere with airflow. se 2. Next to outside air inlets (unless the intent is to Boobbsstr ctio n monitor smoke entry from that area). 3. In return air damper branch ducts and mixing areas Return air 6 Duct Wet ~ r~6 Duct where airflow may be restricted. ~ widBts widths r minimum minimum Outdoor Applications Note: For outdoor applications, refer to data sheet S4098-0032 for information on weatherproof enclosure 4098-9845. General Mechanical and Environmental Air Velocity Range (linear ft/min) 300 to 4000 ft/min (91 to 1220 m/min) Sensor Sensitivity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 01 F to 140° F (-181 C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Black base with clear cover Remote Status/Alarm LED and Test Station with Remote Status/Alarm LED Remote Alarm LED Current 1.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum Addressable Operation Data Communications IDNet or MAPNET II communications, auto-select, one address per housing; provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control, Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC (24 VDC nominal) Standby Current 3 mA @ 24 VDC Alarm Current (one relay activated) 15 mA @ 24 VDC; add 15 mA for each additional remote 4098-9843 relay For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft Supervised Remote Relay Control Output (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 kn, 1/2 W end-of-line resistor 4098-9843 Relay Output Ratings, Single Form C, use with Model 4098-9756 Only Coil Current 15 mA @ 24 VDC, up to 15 maximum per relay control output 7 A at 0.35 PF @ 28 VDC & 120 VAC Relay Contacts 250 pA @ 5 VDC Location Distance 500 ft (152 m) maximum to relay coils; relays must be within 3 ft (1 m) of device being controlled per NFPA 72 Tyco, Simplex, the Simplex logo, 1'rueAlarm, IDNei, and MAPNET 11 are trademarks oflyco International Services AC or its affiliates in the US. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Ftre Protection Association (NF PA). Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4098-0030-5 3/2007 f3 0511''t X www.tycosafetyproducts-usa-wm.com 0 2007 T}+co Safety Products Westminster. All rights reserwed All specifications and other irrfarmalion shown were current as ofdocument revision date and are subject to change widwnt notice. G .Simplex Multi-Application Peripherals UL, ULC Listed, FM, CSFM, IDNetTm Communicating Devices and MEA (NYC) Approved* Model 4090-9002 Relay IAM IDNet addressable interface modules' for use ~ o o with Simplex® models 4010 and 41000 fire alarm control panels 4090-9002, Individual Addressable Relay Module (Relay IAM): • A single addressable point provides control and ® status tracking of a Form "C" contact O(b 7a- • Low power latching relay design allows IDNet ; r .~ooo communications to supply both data and module power C~ o o Compact, sealed construction: ~J • Enclosed design minimizes dust infiltration 4090 Series IDNet Relay IAM Package • Mounts in standard 4" square electrical box (shown approximately 1/2 size) • Screw terminals for wiring connections • Visible LED flashes to indicate communications ' • Optional covers are available to allow LED to be (Refer to Installation Instructions 574-184 for additional viewed after installation information.) UL listed to Standard 864 Communications 4010 or 41000IDNet, I address per device Relay LAM Power Supplied by IDNet communications IDNet Relay IAMs allow fire alarm control panels to Type Form C, SPDT control a remotely located Form "C" contact using IDNet 2 A @ 24 VDC, for transient addressable communications for both data and module Contact Power-Limited suppressed loads power. Typical applications would be for switching local Ratings 1 A @ 24 VDC for inductive loads power for control functions such as elevator capture, or 112 A @ 120 VAC, for transient control of HVAC components, pressurization fans, Nonpower-Limited suppressed loads dampers, etc. Relay status is also communicated requiring only one device address. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mn>z ) F -3 NO RA NOR Up to 2500 ft ( 762 m) from fire alarm Model I Description control panel 4090-9002 Relay IAM IDNet Wiring Reference Up to 10,000 it ( 3048 m) total wiring distance (including T-Taps) Optional Trim Plates Compatible with Simplex 2081-9044 Model Description Overvoltage Protectors 4090-9801 Trim plate with LED For semaflush 4-1/8"H x 4-118° W x 1-3/8"D viewing window, includes mounted box Dimensions (105 mm x 105 mm x 35 mm) mounting screws; For surface 4090-9802 galvanized steel mounted box Housing Material Black themloplastic Mounting Plate Material Sheet metal, galvanized Temperature Range 32° to 120° F (0° to 49° C), This product has been approved by the California Stye Re Marshal (CSFM) pursuant to intended for indoor operation Section 13144.1 of the California Fleallh and Safety Code. See CSFM Ustirg Humidity Range Up to 93% RH at 100° F (38° C) 73000026223 for allowable values andlor condiions concerning material presented in this document. it is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be " IDNet addressable communications are protected by U.S. Patent No. 4,796,025. applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4090-0002-6 2/2004 CD MINIMUM O CD 0 O O Address setting under 0 resealable label O ~ O O 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) 4090-9002 Relay [AM ® Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate Light pipe for LED viewing 4-9/16" 4-5/16" (116 mm) (109 mm) T IF 4-9/16° (116 mm)- ~ ~4-5116' (109 mm)?) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED Tyco, Simplex, the Simplex logo, and IDNet are tra&marks of Tyco International AG or its qffiludes in the US . and/or other countries. g Tyco Safety Products Westminster ° Westminster, MA ° 01441-0001 ° USA S4090-0002-6 2/2004 0SII'Y1 X www.tycossfetyproducts-use-wm.com C 2004 Tyco Safety Products Westminster. All rights reserved All specifwations and other information shown were current as of document revision date and are subject to change without notice. G®SjmpleX TrueAlarm® Addressable Fire Alarm Control Panels UL, ULC, CSFM Listed; FM Approved; 4008 Fire Alarm Control Panel for IDNetTm Addressable MEA (NYC) Acceptance" Devices and TrueAlarm Addressable Smoke Detection Control panel operator convenience features: 1111111111111111111111N11111{Nillll{IIIIIIIIIIII~ • Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient panel status information • Operation is programmable using a multi-function keypad and the panel LCD or via service computer (PC) 1 T • RS-232 service port provides upload/download PC access for panel configuration and event history logs j • Software updates are via PC download • Convenient library of standard custom label terms • Standard on-board DACT provides: Contact ID, 3/1, 4/2, BFSK, and SIA formats IIIIIIUIiIIIIIIIlI111N11111(Iflllll~Illlllll • WALKTESTrm silent or audible system test** • Voltage and current for both the battery charger and the 4008-9101 Standard Control Panel battery can be displayed at the front panel LCD Addressable Devices: 111111111111111111111HIIIHIIIIINIIIiIIINllllll • Using IDNet communications, up to 200 addressable "•r` TrueAlarm detection points or addressable device points ° are available (see page 3 for details)** Two Standard Notification Appliance Circuits (NACs): • Class A or Class B outputs with solid state overcurrent O protection per NAC, each rated for 2 A • Selectable for Simplex® SmartSynem two-wire horn/strobe control or synchronized strobe control** Standard Power Supply: • Provides 3 A maximum @ nominal 24 DC 111111111111111111111111H1111111111111111{1111111 • Automatic input power selection operates with 120 VAC or 240 VAC, 50 or 60 Hz 4008-9121 Control Panel with 24 LED Annunciator • On-board temperature compensated battery charger for (required for ULC applications) up to 12.7 Ah batteries in cabinet (UL and ULC) and up to 25 Ah batteries in separate cabinet (UL only) Additional standard features: Fir-INN' 1-121 • Programmable Active Status Reminder For areas requiring up to 200 addressable input devices and • Two auxiliary relays up to 4 NACs, the Simplex 4008 Series fire alarm control panels provide flexible initiating circuit monitoring, • NACs, Relay outputs, and communications circuits extensive programmable control capability, and LCD are power limited (AC input, battery circuits, and City annunciated circuit-specific 20 character custom labels. Circuit Module outputs are non-power limited) • Available with red or beige cabinet See page 2 for additional ULC and MFA information. This product has been approved by • UL listed to Standard 864 the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:318 for allu wable values and lor conditions concerning material presented in this document. It is subject to reexamination, Available option modules: revision, and possible cancellation. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time • Door mounted 24 LED annunciator (standard on ULC Recorder Co. are the property of Tyco Safety Products Westminster, models) TnueAlann analog smoke defection is protected by one or more of the following U.S. • 3 A Expansion Power Supply with two on-board 2 A Patents: 5,155,468; 5,173,683; 5,543,777. IDNet addressable communcatioons are protected by U.S. Patent No. 4,796,025. IDNet duplicate device detection is protected NACs that operate the same as standard NACs under U.S. Patent No. 6,034,601. WALKTEST system test Is protected under US Patent City Interface Module and Auxiliary Relay Module No. 4,725,818. SmarlSync horn/strobe operation is protected under U.S. Patent No. • y 6,281,789. Two-wire synchronization circuit operation is protected by U.S. patent No. • Remote LCD and LED/Switch Annunciators 5,559,492. S4008-0001-4 10/2006 Addressable operation is provided by an IDNet On-Board Dual Line DACT. Operation can be selected signaling line circuit (SLC) capable of communicating to up for Contact ID, SIA, 3/1, 4/2, and BFSK formats. to 200 addressable devices (points). Addressable devices Reporting includes Alarm, Supervisory, Trouble, and AC include: TrueAlarm smoke detection, heat detection, and Failure. Operation includes automatic 24 hour test and duct detection; supervised addressable modules for single programmable power fail report delay. and multiple contact monitoring, manual stations, isolation Power Supply and Battery Charger. DC power output modules, and a remote signal module (see list on page 4.) is 3 A @ 24 VDC for panel use. The temperature (Please note that this panel provides a limited TrueAlarm compensated battery charger (sealed lead-acid batteries operation feature set. For larger applications that require the only) is rated for up to 25 Ah batteries per UL 864 and up full complement of TrueAlarm features, contact your local to 12.7 Ah per ULC-S527. (Up to 12.7 Ah batteries fit in Simplex product supplier.) the cabinet, larger batteries require an external cabinet.) Panel electronics can measure and display voltage and Two, 2 A On-Board NACs provide conventional reverse current for the power supply, batteries and the battery polarity operation, selectable as Class A or Class B, with charger (standard and expansion power supply). Depleted electronic control and overcurrent protection. Operation is battery trouble is monitored and annunciated and depleted selectable for synchronized strobe or SmartSyncTM battery cutout can be selected. Active battery status horn/strobe two wire operation. Horn control can be monitor supervises charger operation. selected at the panel for: Temporal pattern coding, Steady • • On, Slow March Time of 20 beats per minute (BPM), or Fast March Time of 120 BPM. Note: When selected for Expansion Power Supply. Provides 3 A total @ SmartSync horn/strobe control, March Time produces 24 VDC, two additional 2 A NACs, and an additional 60 BPM. auxiliary power output of 500 mA. Output operation is the The 24 VDC Auxiliary output provides up to 500 mA same as on the standard power supply. for system use. (Auxiliary output current is counted for Expansion Relay Module. Provides three relays, one total power supply capacity.) each for Alarm, Supervisory, and Trouble conditions. Each is jumper selectable as N.O. or N.C. Contacts are Standard Auxiliary Relay Outputs. Two relay outputs rated 2 A @ 30 VDC. Location is the same as for the City are available, selectable as normally open or normally Circuit Modules. closed, rated 2 A @ 30 VDC per below: City Circuit Modules. These modules are available with Aux Relay 1 is normally assigned to General Alarm or without on-board disconnect switches, depending on operation but is programmable (see page 7) local requirements (either type can be disconnected Aux Relay 2 (Trouble) is energized when Normal and is through the front panel under password control). de-energized with a Trouble condition. Connections are for Remote Station (reverse polarity) or Municipal Master (local energy). Reporting includes • Alarm, Supervisory, and Trouble. Control Panel Model Color Description Box Depth Listings Standard Feature Summary 4008-9101 Red Standard fire alarm control panel 4-1/4" MEA SLC with 200 addressable points, 4008-9102 Beige (108 mm) UL, FM, & 2 Class B/Class A NACs, 3 A power 4008-9121 Red Fire alarm control panel with 4-5/8" CSFM supply with battery charger; on-board 4008-9122 Beige 24 LED Annunciator on front door (117 mm) ULC DACT; for input voltage of 120/240 VAC, 50/60 Hz (autoselect) Option Modules Model Description 4008-9801 Expansion Power Supply; 3 A, with 2 NACs, 120/240 VAC, 50/60 Hz Select one if required 4008-9802 Expansion Relay Module; 3 relays selectable as either N.O. or N. C. 4006-9805' City Circuit Modules with disconnect switch Select one if required 4006-9806" City Circuit Modules without disconnect switch * These City Circuit modules are also used on the 4006 Series control panels. Accessories Model Description 2975-9812 Red semi-flush trim kit; 1-7/16" (37 mm) wide; includes four comers and trim pieces for top, bottom, and sides 2975-9811 Beige semi-flush trim kit; 1-7/16" (37 mm) wide; includes four corners and trim pieces for top, bottom, and sides 4009-9801 Beige External Battery Cabinet for up to 25 Ah batteries; mounts dose-nippled to control panel cabinet; dimensions = 16-1/4" W x 13-1/2" H x 5-314" D (413 mm x 343 mm x 146 mm) [depth increased for 25 Ah effective 72005] Batteries, 12 Volt (select one battery model per system standby requirements; order quantity of two) Model SModel Size Location Model Size Location 2081-9272 62179h 2081-9288 12.7 Ah For cabinet mount 2081-9275 18 Ah Requires 4009-9801 External Battery 2081-9274 10 Ah 112081-9827 25 Ah Cabinet (UL listed only) 2 S4008-0001.4 10/2006 TrueAlarm Addressable Detection. IDNet addressable Status Monitoring. 4008 TrueAlarm operation provides device compatibility includes Simplex TrueAlarm the ability to automatically indicate when an addressable photoelectric smoke and temperature sensors. The 4008 fire detector is dirty or excessively dirty. The NFPA 72® alarm control panel provides a subset of the complete (National Fire Alarm Code requirement for a test of the analog TrueAlarm features. TrueAlarm sensors appear to sensitivity range of the detectors is fulfilled by the the panel essentially as addressable detectors and that term TrueAlarm ability to maintain the sensitivity level of each is used for 4008 documentation. addressable detector. Approximately every four seconds the addressable smoke Modular Addressable Detector/Base Combination. detectors transmit an output value based on their smoke Modular TrueAlarm addressable detectors use the same base chamber condition. The panel CPU internally maintains a which allows different detector head types (photoelectric current value, peak value, and an average value for each smoke, or heat) to be easily interchanged to meet specific detector's output. Status is determined by comparing the application requirements. This feature also allows current value to its average value. Tracking this average intentional detector (sensor head) substitution during value as a continuously shifting reference point filters out building construction. When conditions are temporarily environmental factors that cause shifts in sensitivity. dusty, instead of covering the smoke detectors (causing Alarm Determination. Photoelectric detection sensitivity them to be disabled), heat detector heads may be installed is 2.50/o/ft obscuration. All detectors can be selected for a without reprogramming the control panel. Although the reduced sensitivity detection mode that satisfies the city of control panel will indicate an incorrect detector type, the Boston requirements. Addressable heat detectors provide a heat detector will operate at a default setting to provide heat fixed temperature alarm at 135° F (57° C) and may be detection for building protection at that location. individually selected to also provide rate-of-rise alarm of 15° F (83° C) per minute where applicable. FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information, LEDs flash to indicate the condition and then when acknowledged, remain on until reset THREE PROGRAMMABLE LEDs 2 X 20 LCD READOUT, LED backlighted during normal conditions and abnormal provide custom labeling (labels insert into operating conditions, provides up to 20 characters for custom label information a pocket), the top two LEDs are FIRST ALARM DISPLAY: Operation can be selected for maintained display of first selectable as red or yellow, the bottom alarm until acknowledged LED is selectable as green or yellow SYSTEM NORMAL 12: 35: 15 Pm 09/25/06 CONTROL PANEL VIEW 177 SYSTEM RESET restores with door dosed a ,r control panel to normal when all alarmed inputs are returned to normal k k k k ALARM ACK acknowledges a Fire ' Alarm condition, logs the ' ALPHANUMERIC acknowledge, silences the operator ' panel and all annunciator tone-alerts, ' KEYPAD provides and steps through the active Alarm list k programming entry of ' numbers and letters r k SUPV ACK acknowledges system i supervisory conditions, logs the ' k acknowledge, silences the operator panel and all annunciator tone-alerts, - _ and steps through the active ALARM SILENCE causes audible notification appliances Supervisory list TROUBLE ACK acknowledges to be silenced, used after evacuation is complete and system troubles, logs the while alarm source is being investigated FIVE NAVIGATION KEYS: MENU selects acknowledge, silences the the on-screen programming menu; left operator panel and all annunciator and right arrows moves the position on the tome-alerts, and steps through the FOUR EXTENDED FUNCTION KEYS: ENTER confirms screen, and PREVIOUS and NEXT active Trouble list selections, EXIT/CLEAR backs out of the present screen menu navigate screen selections and dears information that has not been entered, FUNCTION enables the active function menu, DISABLE/ENABLE toggles the function or circuit status as appropriate per the selected screen 3 S4008-0001-4 10/2006 CompatibileSimplex Peripherals Detector Heads and Addressable Bases (refer to page 3 for 4008 detector/sensor terminology) Model Detector Head Type Compatible Addressable Base Data Sheet 4098-9792, Standard detector base 4098-9714 Photoelectric 4098-9789, Base for remote LED or relay S4098-0019 4098-9791, Features of 4098-9789 and remote supervised relay 4098-9733 Heat, 135° F (57° C) 4098-9794, Sounder base S4098-0028 4098-9793, IDNet Isolator base S4098-0025 4098-9754 Photo and Heat 4098-9795, Dual address sounder base NOTE: These bases require S4098-0033 4098-9796, Dual address standard base two addresses Duct Detection Model Description Data Sheet 4098-9755 Addressable Duct Detector Housing with 4098-9714 detector, no relay control S4098-0030 4098-9756 Addressable Duct Detector Housing with 4098-9714 detector, with remote relay control Addressable Devices Model and Description Data Sheet Model and Description Data Sheet Model and Description Data Sheet 4090-9001 Supervised IAM S4090-0001 4090-9101 CL B ZAM S4090-0003 4090-9007 Signal IAM S4090-0010 4090-9051 Supervised [AM 4090-9106 CL A ZAM 4099-9001, 4099-9002, Z& 4099-9003 Manual S4099-0001 4090-9002 Relay IAM S4090-0002 4090-9116 IDNet Isolator S4090-0005 Stations Compatible System Expansion Panels Model Type Description Data Sheet Provides a remote voice control panel with on-board NACs, internal 4003 Series Voice Control Panel microphone, and remote microphone input 54003-0001 4009 Series Remote NAC Extender Provides remote NACs; includes power supply and battery charger; 54009-0002 4 extenders max/NAC; 4008 uses NAC output to provide control Note: Contact your local Simplex Product Supplier for additional compatible peripherals. • - • • • • 11 The 4008 supports up to four annunciator options including: 4606-9101 LCD Annunciator Features: Door Mounted 24 LED Annunciator • LCD readout with two lines of 40 characters each and • 4610-9111 Remote LED/Switch Annunciators LED backlighting • Wide viewing angle, super-twist design • 4606-9101 Remote LCD Annunciators Annunciators communicate at a rate of 9600 baud with • Keyswitch access controlled power supplied by separate wiring. Control switches and status LEDs for: 4610-9111 LED Annunciator Features: • Alarm, supervisory, or trouble acknowledge • 16 LEDs with programmable functions and dedicated • Alarm silence and System Reset LEDs for Alarm Silenced, Lost Communications, Three programmable LED indicators: Trouble, and Power-on • Two LEDs are selectable as red or yellow • Keyswitch access controlled switches for Acknowledge, Alarm Silence, Reset, and Lamp Test • One LED is selectable as green or yellow • Local tone-alert • With provisions for custom labeling m m A~ svsroi is Noi O . la 35t 15 an NON 13 MAR e6 ~ e19rNllec ~ m m ¦s~a• 4610-9111 LED/Switch Annunciator 4606-9101 LCD Annunciator 4 S4008-0001-4 10/2006 s • • • • • • • • Input Voltage 120 VAC, 60 Hz; 220/230/240 VAC, 50/60 Hz, auto-select AC Input Input Current, Standard 2 A maximum @ 120 VAC input; 1.5 A maximum @ 240 VAC input Input Current with 4 A maximum @ 120 VAC input; 3 A maximum @ 240 VAC input Expansion Power Supply Power Supply Output 3 A maximum @ 24 VDC in alarm Battery Charger Temperature compensated charger is rated for up to 25 Ah per UL 864; up to 12.7 Ah per ULC-S527 Notification Appliance Circuits (NACs) (NOTE: Total DC current = 3 A maximum per power supply) General Rating 2 A maximum @ 24 VDC, per NAC; available as Class A or Class B; Class B end-of-line resistor = 10 ko, 1/2 W; Model 4081-9008 (P/N 733-894) Special Application Rating = 2 A per NAC Simplex 4901 Series (homs) and the following 4906 Series Mufti-Candela: strobes, Strobe synchronization is UL listed across all hom/strobes, and speaker/strobes (see data sheets S4906-0001, S4906-0002, & four system NACs for these 4906 Series S4906-0003 ) appliances 4906-9101 4906-9103 4906-9127 4906-9129 4906-9151 4906-9154 4906-9102 4906-9104 4906-9128 4906-9130 4906-9153 Regulated 24 VDC Rating = 1.5 A per MAC NOTE: Maximum strobe load on main power supply or expansion power supply is 1.35 A Ali other UL Listed Notification Appliances; use associated external per power supply (2.7 A total); remainder of synchronization modules where required power supply rating is available for other loading Standard Circuit Ratings (NOTE: Total DC current = 3 A maximum per power supply) Auxiliary Power Output 500 mA maximum @ 24 VDC Standard Auxiliary Relay Outputs Relay 1 Programmable operation Contacts rated 2 A @ 30 VDC, 0.35 power factor; Relay 2 Trouble operation jumper selectable as N.O. or N.C. Wiring Connections Terminals rated for 18 AM to 12 AWG (0.82 mm to 3.31 MM 2) IDNet Communications Quantity Up to 200 addressable devices (see list on page 4) Suppression For wiring external to building, use Overvoltage Protector 2081-9044 at each end of the connection; refer to data sheet S2081-0016 for details Wire Size 18 AWG (0.82 mm2) Unshielded twisted pair (UTP) Acceptable for most applications; not for use with wiring in conduit with either NAC or AC power wiring (or similar) Wire Types Shielded wire may provide protection from unexpected sources of interference and Shielded twisted pair (STP) may be required for some applications; review system with your local Simplex product supplier Distance from Control Panel to Farthest Up to 4000 feet (1219 m) with 125 devices; 32 n Device Up to 2500 feet (762 m) with 200 devices; 51 0 Total Wire Length Allowed With "T" Taps for Up to 10,000 ft (3 km) Class B Wiring Total Capacitance Allowed 0.6 pF (600 nF) Annunciator Communications Quantity Supported Up to four annunciator modules per panel (see page 4 for details) Wiring Size and Type See description for IDNet wiring above Wiring Distances Bus-Style Wiring Up to 4000 ft (1219 m); 0.58 pF (580 nF) maximum capacitance; 35 n max. "T-Tap" Wiring Up to 10,000 ft (3048 m) total wiring; up to 2500 It (762 m) to farthest device Line Matching Resistor Bus-Style Wiring Connect one at panel and one at end of line 100 S2, 1/2 W; 4081-9011; "T-Tap" Wiring Connect one at panel and one at farthest device (part number 733-974) Suppression Use 2081-9044 Overvoltage Protectors where wiring leaves and enters a building (refer to data sheet S2081-0016) Option Module Ratings Expansion Relay Contact Ratings 2 A @ 30 VDC, 0.35 power factor; jumper selectable as N.O. or N.C. Module 4008-9802 Wring Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) Environmental Ratings Operating Temperature Range 32" to 120°F (0" to 49" C) Operating Humidity Range Up to 93% RH, non-condensing @ 100.4° F (38" C) maximum 5 54008-0001-4 10/2006 Model Module Supervisory Alarm 4008-9101 Standard fire alarm control panel with 50 175 mA 200 mA IDNet devices 4008-9121 Control panel with 24 LED Annunciator 193 mA + 1 mA per IDNet device 250 mA+ 1 mA per IDNet device 4008-9801 Expansion Power Supply 50 mA 60 mA 4008-9802 Expansion Relay Module 10 mA per energized relay 10 mA per energized relay 4008-9805 City Circuit Module with disconnect switch 30 mA 60 mA 4008-9806 City Circuit Module without disconnect 30 mA 60 mA switch 4606-9101 Remote LCD Annunciator (see data sheet 100 mA 150 mA S4606-0001) 4610-9111 Remote LED/Switch Annunciator (see 40 mA 70 mA data sheet 54610-0001) (all LEDs and tone-alert on) Current Calculation Information: 1. To determine total supervisory current, add currents of modules in panel to base system value and all auxiliary loads. 2. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all auxiliary loads. The following addressable device types and hardware point types are provided. A combination of autoprogram, and either front panel or PC programming allows the operation to be selected per application. Available Fire Detection Device Types Device Description Options Photoelectric Sounder base (selectable With communications isolator Addressable TrueAlarm operation with for single station operation) Detector sensitivity = 2.5%/ft With relay output Selectable for all detectors to be at city of Boston sensitivity of 3.7%/ft Sounder base (selectable With communications isolator Heat Detector Fixed temperature thermal for single station operation) detection at 135° F (57.2° C) Individually selectable to add rate-of-rise heat With relay output detection of 15° F/minute (8.3° C/minute) Addressable Hardware Point Types Function Type Description Function Type Description FIRE Fire monitor device WSO Combination waterflow and water supervisory device WATER Waterfow monitor device SUPV Supervisory monitor HEAT Heat detector device UTIL Supervised utility monitor DUCT Duct detector device TROUBLE Trouble monitor PULL Manual (pull) station device VSMOKE Verified fire alarm; an alarm level causes the alarm verification cycle to start SMOKE Smoke detector device STYLEC Style C fire monitor so Sprinkler Supervisory LATSUPV Latching supervisory monitor (supervisory latches until system is reset) 6 54008-0001-4 1012006 Man • The following relay operations are selectable from either the front panel or the PC programmer. Common Fire Alarm Operations Function Type Relay Activates Upon Relay Deactivates Upon SRELAY General Alarm Silence RRELAY General Alarm Reset SUPV Supervisory condition Clear TRBL Trouble condition Acknowledged Special Functions Function Type Description UTILITY Utility input in the same alarm group activates PRIMARY General alarm; relay is tied to Primary Elevator Recall contacts ALTERN General alarm; relay is tied to Alternate Elevator Recall contacts DRESET Relay provides 24 VDC power to 4-wire addressable detectors; relay turns off for 5 seconds on System Reset DHOLDER Relay provides 24 VDC to larger door holder relay with separate power source; relay activates on general alarm to remove power to door holder relay and dose doors FORM. • • O• PHN Function Details Custom labels Up to 20 characters per point; a built-in message library provides for commonly used words for easy front panel programming For front panel label creation convenience, the following words can be selected as part of a custom label ( -designates a built-in space; typing the first letter of a word/number will select the closest word in alphabetical/numerical sequence) Message Library North Center Basement Lobby main Boiler RM Elevator Fir 3 Floor South rear Flr 4 Garage Office first Classroom Entrance Storeroom East 5th Fir 5 Hallway Patient 2nd Closet Restroom Wing West Fir 1 RM HVAC Room upper 3rd Corridor Room Zone Front Flr 2 - Kitchen tower 4th Elect RM Stairway Three separate logs: Alarm (100 entries), Supervisory (100 entries), and Trouble (300 entries); logs can be History logs queried separately, or as a combined log; logs can be downloaded for printing or archiving using the RS-232 service port Automatically scans system for installed option modules and configures panel programming accordingly; Autoprogram modes are available to detect new modules only, recreate default programming and then add all modules found; Scans of addressable loop adds addressable devices, displays total added; checks for duplicate addresses and identifies errors Alarm Groups Up to 99 alarm groups are available, any point may be in up to 3 alarm groups; this allows NAC and relay operation to be associated with inputs according to local response requirements WALKTEST Allows one person to perform system testing; alarm or trouble tests are followed by automatic reset; the alarm zone is sounded out by associated audible notification or the response is silentty togged into the Alarm log Manual Control Allows selection of individual relays or NACs for system testing Passcode Level 1 = Acknowledge, Silence, System Reset, View logs, View point information, and Lamp Test Protection Level 2 = All Level 1 + Set Time/Date, Point Control, Enable/Disable points (4-digit number) Level 3 = All Level 2 + Clear logs, Clear verification tallies, Custom label editing, and WALKTEST Level 4 = All Level 3 + Programming, Upload/Download; this is the Service access level 7 S4008-0001-4 1012006 r - -Box width 15-5/8" (397 mm) ?I Knockouts are (Top and side views are located on top shown with door installed) and sides O O O O O Box depth = 4-1/4"(108 mm) standard 4-5/8" (117 mm) w/annunciator door 11-1/4"(286 mm) Main board 0 0 Door thickness 5/8" (16 mm) 0C= 0 = D000 ° 13-1/2" A ~mb 343 mm l a Expansion 6 mm) ( ) y 0 Power Supply` (406 , , e e Main board ® e e AC Input Terminals City Module' ; I F- QE Expansion , Relay Module' Battery Area O No conduit or wiring in this area 13-1/4" (337 mm) NOTE: For semi-flush mounting, cabinet ' Indicates optional modules must extend 1-1/2" (38 mm) minimum from wall surface YELLOW LED RED LED 14 CUSTOM LABEL AREAS are available, typically for location AREA 1 AREA 5 AREA 9 identification and NAC annunciation (shown labeled for AREA 2 AREA 6 AREA 10 reference, blank labels are provided); dual LED locations have AREA 3 AREA 7 a Red LED (top) and a Yellow LED (bottom); labels insert into pockets AREA 4 AREA $ NAC 3 behind the overlay; LED operation LA NAG 4 is programmable to track other monitored status conditions FOUR YELLOW LEDs provide default NAC Trouble annunciation (shown labeled as NAC 14) Tyco, Simplex, the Simplex logo, TrueAlarm, IDNet, WALKTF.ST, and SmartS}vnc are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4008-0001-4 10/2006 G.Simplex www.tycosafetyproducts-usa-wm.com ,c 2006 Tyco Safety Products Westminster All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice.