07201657 Permit File 1 - o%e CITY OF DUBLIN ~ftf RECEIVED n of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 NOV 3 0 2007 WTFD: (614) 652-3920 ,31JILDiNO DIVISION FIRE PROTECTION PERMIT APPLICATION CIT`! OF DUBLIN Application Date Bldg. App. # Fire Protection App. # ( T O 40 PROJECT INFORMATION ~t " Project Address 11 kOO \ CGs ~~OA -ta , Project Name k~vme)'- Owner/Tenant Contact Name Telephone APPLICANT INFORMATION _ Fire Protection Contractor _ C T Address 2 Mores ` i Telephone. 1/1 lq- 3 7 7 2-0 State Certificate Number p 2 ' Dublin Registration Number Installer Name r 0;Fg!a 122 L- Lcal,-AA1 State Certificate Number-5'-z/- 8'31222- SCOPE OF WORK (Mark One) New Replace Repair Alteration FIRE DETECTION AND ALARM SYSTEM (Number of Each) Detectors yo" Strobes Horns Fire Alarm Boxes Other i110111- SUPPRESSION SYSTEM (Number of Each) Standpipes On Site Water Piping Sprinkler Heads Limited Area Other FEES ~O FIRE DETECTION OR SUPPRESSION PERMIT PROCESSING FEE LOW VOLTAGE PERMIT (DETECTION ONLY) $30.00 Minimum fee ob plus $20.00 each 1,000 sq ft or fraction thereof over 1,000 sq ft OUTSIDE PLAN REVIEW SERVICES (EXAMINER'S FEE AS CHARGED) STATE SURCHARGE (3%) TOTAL FEE DUE Q a. •~'C~c This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. This permit conveys no right to open any street, alley or sidewalk jorany part th f, or to make any connection to a water main. Signature of Licensed ContractorDATE Print Name c rf v -I- DATE 30_4:55 7 FOR OFFICIAL USE ONLY Review Comments: - T`ie iii'/orm conloogP~~ G~i~rcvii~y~saeG 7~r f/~ _ 9~~~~-SSg6/c u e for ;Mr oral Coo -5 ems- WpsA' Tow,ul, is ,moo rnrof g ~v 4w, Fire Department: 6e Date: /a -fl d Plans Examiner: Date: 2 21 n Issued by CBO: Date: tz a7 CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00201657 Date 12/21/07 Revision number . . . . . . . 1 Property Address . . . . . . 7100 HOSPITAL DR Parcel Number: 273-008209 Alternate Address: KROGER Tenant nbr, name . . . . . . KROGER DELI DETECTION Application type description FIRE PROTECTION Property owner . . . . . . . DUBLIN OAKS LIMITED Contractor . . . . . . . . . VECTOR SECURITY Permit . . . . . . LOW VOLTAGE ELECTRIC PERMIT Additional desc . . Permit Fee . . . . 30.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/18/08 Qty Unit Charge Per Extension BASE FEE 30.00 Permit . . . . . . FIRE DETECTION PERMIT Additional desc . . Permit Fee . . . . 60.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 60.00 Special Notes and Comments CONTACT WASHINGTON TOWNSHIP FIRE PREVENTION FOR INSPECTIONS AT 766-0857 Other Fees . . . . . . . . . SURCHARGE FEE - ELECTRIC .90 SURCHARGE FEE - FIRE 1.80 Fee summary Charged Paid Credited Due Permit Fee Total 90.00 .00 .00 90.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 2.70 .00 .00 2.70 Grand Total 92.70 .00 .00 92.70 i This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 CORRECTION REQUEST #1 This is not a Building Permit. It is a record of our review of documents submitted with your application for a Building Permit. December 11, 2007 RE: Kroger APPLICANT: Andrew J. Conti, Vector Security, 614.367.7820 ADDRESS: 7100 Hospital Road APPLICANT NO. 07-201657 The plans received Nov 30, 2007 have been reviewed for compliance with the provisions of the Ohio Building Code (2007). The review was based upon the following criteria: Use Group: M- Mercantile Area: Not Noted SF Occupant Load: No Change Construction Type: IIB Notes: The fire alarm system documents were prepared by Vector Security, Ohio certified contractor 54-831222 to comply with the requirements of the OBC Section 106.3.4.1 and have been reviewed, therefore, in accord with OBC Section 104.1. OBC 106.3 Examination of documents. The building official shall examine or cause to be examined the accompanying construction documents and shall ascertain by such examinations whether the construction indicated and described is in accordance with the requirements of this code. The construction documents, which have been submitted, do not allow the City of Dublin to issue a permit to begin construction. The following item(s) shall be brought into full compliance with the the requirements of the OBC prior to the issuance of any plan approval. Item 1 The Washington Township Fire Marshal has requested an opportunity to provide input to the Dublin building department on issues relating to fire protection. The building official has evaluated the Fire Marshal's comments related to the fire protection provisions of the OBC and incorporates those comments, by reference, into this Correction Request. a. Please include resolution of the matters of the Fire Marshal's correspondence to Building Standards in your reply to this Correction Request. This review is based upon the information contained within the submitted drawings and related documents. Once corrections are made, submit four (4) new and complete sets of plans to the City of Dublin, Division of Building Standards with any revisions clouded. Please also provide a letter that identifies the action taken in rsponse to any of the Items contained in this Correction Request. TO REQUEST AN APPEAL HEARING, YOU MUST sent a written request, listing the items to be appealed and the relief sought and a copy of this order to: Kroger - Fire Alarms Application No.: 07-201656 December 11, 2007 Page 2 of 2 Jeffrey S. Tyler, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 Red e and Signed C~L-s2 R y M. H ham, A A t Jeffrey S. Tyler, AIA Commerc*al Plans Examiner Chief Building Official Lo a - 11-5~ -01~& O r or Owner's Rep se ative Date Print Name and Title as Signed N:\Building Standards\Harpham\Reviews 2007\07-201657 c 1 Kroger FA.doc • • COUNTIES OF WASHINGTON TOWNSHIP FIRE DEPARTMENT 6200 Eiterman Road, P.O. Box 3248 ER^NDublin, Ohio 43016 :1' 614-652-3920 • Fax 614-766-2507 Date: 7 Z~mwnber A007 To: Jeff Tyler, Director City of Dublin Division of Building Standards 5800 Shier Rings Road Dublin, Ohio 43016 Re: Washington Township's Fire Department Plan Review Permit 07- go/& S 7 Project: /"1 /'ogcc»r (,iie 1r/41/m w/7C'/icy Location: 7100 ifurdit4/ .D~ Received: 3o /1/o?~mber aod7' Review Comments: Di.SgDDro v~a~ :K The Ai G~rAcr~~i~ q~D~s tor` 1-nee-l N/oYA1 n ow Fi' fi via e•/~a~i' / e cc>7 cfion diQUr/ .sue P is /i~sv~~:~i~nt 1Ni //~7Q~io icy i- i~ Sao P o~ wog' a e,, OBG O7 Coiisfi vcfioh 4zo U i s 9fi o i r PQ~ 0, t e P P oa )sec s'h Pry is a gc~c~iPssg /e n, o~i i4~r ~d~u/P. X/9Xl~ Ch e Ccbkes Suc/oIPX-Scm me'Wi A- /..,~e e 'I I I. No q~efer oiv Its /,1001 Reviewed By: Trustees Gene Bostic • Denise Franz King • Charles Kranstuber Fiscal officer Joyce E. Robinson Chief Allan Woo CITY OF DUBLIN RECEIVED n of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 NOV 3 0 2007 WTFD: (614) 652-3920 BUILDING DIVISION FIRE PROTECTION PERMIT APPLICATION CITY OF DUBLIN Application Date 11-3f1°1~M7 Bldg. App. # Fire Protection App. # OT 0')c1(40S PROJECT INFORMATION , ` i r Project Address rl 1C30 t~ OS~r~'tOA -b(, Project Name v ookey- Owner/Tenant Contact Name Telephone APPLICANT INFORMATION Fire Protection Contractor V G: k S k~_ C ? 12 Address 2 lnol5rksoei 9J Telephone - 3 7- ? 21) State Certificate Number O Dublin Registration Number Installer Name State Certificate NumbecS'- 8"31222- SCOPE OF WORK (Mark One) New Replace E~ept~r Alteration FIRE DETECTION AND ALARM SYST ~~,ljurlber.of Each) Detectors Strobes Ngrr~s Fire Alarm .Bares Other SUPPRESSION SYSTEM (Number ofach' Standpipes On Site Water Piping *rinKle.r Heads Limited Area Other FEES FIRE DETECTION OR SUPPRESSION PERMIT PROCESSING ; LOW VOLTAGE PERMIT (DETECTION ONLY) $30.00 Minimum fee ' 0e plus $20.00 each 1,000 sq ft or fraction thereof over 1,000 sq ft OUTSIDE PLAN REVIEW SERVICES (EXAMINER'S FEE AS CHARGED), STATE SURCHARGE (3%) TOTAL FEE DUE This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. This permit conveys no right to open any street, alley or sidewalk or any part th f, or to make any connection to a water lmain. Signature of Licensed Contractor DATE 3~O"0'7 Print Name X7. eo"4J"t' ( DATE l/' 3d 6~ M FOR OFFICIAL USE ONLY Review Comments: Fire Department: 16AP PROVED Date: Plans Examiner: Date: Issued by CBO: Date: • • OF WASHINGTON TOWNSHIP UNTIES FIRE DEPARTMENT ~h9q : z 6200 Eiterman Road, P.O. Box 3248 F'%NKN Dublin, Ohio 43016 614-652-3920 • Fax 614-766-2507 Date: 7Aerein6Fr 0007 To: Jeff Tyler, Director City of Dublin Division of Building Standards 5800 Shier Rings Road Dublin, Ohio 43016 Re: Washington Township's Fire Department Plan Review Permit 07-,9016,T7 Project: ff /'ooer rx"ie 4/Q~~r, 4/err icri Location: 7100 6 soi 4/ ,Dr Received: 30 11/ 04"her -2t-v7 Review Comments: ~i.S4DDro vial * The Ar G~r4u..i~ q~oPSS aof ~n jjknhi OW ~ cr/ 7` vA e/7C~i T!e caos~`rucf_1 on dlQw/r~Ab~i" is wi a P/ OB 07 Ctvls'fi'vc~io o U ~'qf/O / r Pc7 266e .1 e P on l s- ~c sh Pry .s a ~/PSSQ 67q~4 Reviewed By: `ire /~I9rsho~ Trustees Gene Bostic • Denise Franz King • Charles Kranstuber Fiscal Officer Joyce E. Robinson Chief Allan Woo DF-52121:A • E-325 MMF-300(A) Series/ FF'IMVIVALdr'MS MDF-300 Addressable Monitor Modules by Honeywell Addressable Devices, General Four different monitor modules are available for Fire•Lite's Q intelligent controls to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, m 9 0 or monitor and power a circuit of two-wire smoke detectors fj I (jg (MMF-302). ~V, 2 MMF-300 and MMF-302 MMF-300 is a standard-sized module (typically mounts to a 4' 6 ; : • 4 [10.16 cm] square box) that supervises either a Class A (Style s , 4 D) or Class B (Style B) circuit of dry-contact input devices. AO0m3s MMF-301 is a miniature monitor module (a mere 1.3- (3.302 cm) H x 2.75' (6.985 cm) W x 0.5- (1.270 cm) D) used to supervise a Class B (Style B) circuit. Its compact design allows the MMF-301 to often be mounted in a single-gang box behind Q the device its monitoring. MMF-302 is a standard-sized module used to monitor and 9 y~ o supervise compatible two-wire, 24 volt, smoke detectors on a detail of MDF-300 - note s I/ttljQ 1 Class A (Style D) or Class B (Style B) circuit. "ones" addresses are 7,0+c x 2 MDF-300 is a standard-sized dual monitor module used to 0, 2, 4, 6, 8 only a `2 3 " monitor and supervise two independent two-wire initiating s 1 4 device circuits (IDCs) at two separate, consecutive addresses „emu in intelligent, two-wire systems. (Z) O o O 0 LiteSpeedTm is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of com munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU may be wired as an NFPA Style B (Class B) or Style D (Class stops the group poll and concentrates on single points. The A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor net effect is response speed greater than five times that of (provided) terminates the Style B circuit. No resistor is other designs. required for supervision of the Style D circuit. Maximum IDC loop length is 2,500 ft./762 m (20 ohms maximum). MMF-300 Monitor Module MMF-300 OPERATION • Built-in type identification automatically identifies this device Each MMF-300 uses one of 159 available module addresses as a monitor module to the control panel. on an SLC loop. It responds to regular polls from the control • Powered directly by two-wire SLC loop. No additional power panel and reports its type and the status (open/normaVshort) required. of its Initiating Device Circuit (IDC). A flashing LED indicates High noise (EMF/RFI) immunity. that the module is in communication with the control panel. • The LED latches steady on alarm (subject to current limita- • SEMS screws with clamping plates for ease of wiring. tions on the loop). • Direct-dial entry of address: 01 - 159 on LiteSpeed sys- MMF-300 SPECIFICATIONS tems, 01 - 99 on CLIP systems. • LED flashes green during normal operation (this is a pro- Nominal operating voltage: 5 to 32 VDC. grammable option) and latches on steady red to indicate Maximum current draw: 5.1 mA (LED on). alarm. Average operating current: 400 pA (LED flashing). The MMF-300 Monitor Module is intended for use in intelligent, EOL resistance: 47K ohms. two-wire systems, where the individual address of each mod- ule is selected using the built-in rotary switches. It provides Temperature range: 32°F to 120°F (0°C to 49°C). either a two-wire or four-wire fault-tolerant Initiating Device Cir- Humidity range: 10% to 93% noncondensing. cuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. Dimensions: 4.5- (11.43 cm) high x 4' (10.16 cm) wide x The MMF-300 can be used to replace M300 modules in exist- 1.25' (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x ing systems. 2.125' (5.398 cm) deep box. MMF-300 APPLICATIONS MMF-301 Mini Monitor Module Use to monitor a zone of four-wire smoke detectors, manual Built-in type identification automatically identifies this device fire alarm pull stations, waterflow devices, or other normally- as a monitor module to the panel. open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special • Powered directly by two-wire FACP. No additional power supervisory indication at the control panel. Monitored circuit required. D F-52121:A - 6/11/07 - Page 1 of 6 • High noise (EMF/RFI) immunity. • Direct-dial entry of address: 01 - 159 on UteSpeed sys- • Tinned, stripped leads for ease of wiring. tems, 01 - 99 on CLIP systems. • Direct-dial entry of address: 01 - 159 on UteSpeed sys- • LED flashes during normal operation (this is a programma- tems, 01 - 99 on CLIP systems. ble option). • LED latches steady to indicate alarm on command from 3 1415 0 1 A R S 0 1 control panel. s 13 2 2 The MMF-302 Interface Module is intended for use in intelli- 3 O 4 LOOP 0.5 4 gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- 10 9 8 7 6 5 8 7 wire conventional smoke detectors. It transmits the status (nor- TENS ONES mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 Z has a panel-controlled LED indicator and can be used to 3 replace M302 modules in existing systems. O Lu O U W p MMF-302 APPLICATIONS 5- > m Use the MMF-302 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for The MMF-301 Mini Monitor Module can be installed in a sin- Style D application. gle-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mount- MMF-302 OPERATION ing. The MMF-301 is intended for use in intelligent, two-wire Each MMF-302 uses one of 159 available module addresses systems where the individual address of each module is on an SLC loop. It responds to regular polls from the control selected using rotary switches. It provides a two-wire initiating panel and reports its type and the status (open/normal/short) device circuit for normally-open-contact fire alarm and security of its Initiating Device Circuit (IDC). A flashing LED indicates devices. The MMF-301 can be used to replace M301 module that the module is in communication with the control panel. in existing systems. The LED latches steady on alarm (subject to current limita- MMF 301 APPLICATIONS tons on the loop). Use to monitor a single device or a zone of four-wire smoke MMF-302 SPECIFICATIONS detectors, manual fire alarm pull stations, waterflow devices, or Nominal operating voltage: 15 to 32 VDC. other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- Maximum current draw: 5.1 mA (LED on). visory indication at the control panel. Monitored circuit/device Average operating current: 270 pA (LED flashing). is wired as an NFPA Style B (Class B) Initiating Device Circuit. EOL resistance: 3.9K ohms. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 MMF-301 OPERATION Vrms maximum. Current: 90 mA per module maximum. Each MMF-301 uses one of 159 available module addresses Requires regulated, resettable 24 VDC power. on an SLC loop. It responds to regular polls from the control Temperature range: 32°F to 120°F (0°C to 49°C). panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). Humidity range: 10% to 93% noncondensing. MMF-301 SPECIFICATIONS Dimensions: 4.5' (11.43 cm) high x 4' (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x Nominal operating voltage: 15 to 32 VDC. 2.125' (5.398 cm) deep box. Maximum operating current: 375 NA. EOL resistance: 47K ohms. MDF-300 Dual Monitor Module Temperature range: 32°F to 120°F (0°C to 49°C). The MDF-300 Dual Monitor Module is intended for use in intel- ligent, two-wire systems. It provides two independent two-wire Humidity range: 10% to 93% noncondensing. initiating device circuits (IDCs) at two separate, consecutive Dimensions: 1.3' (3.302 cm) high x 2.75' (6.985 cm) wide x addresses. It is capable of monitoring normally open contact 0.5' (1.270 cm) deep. fire alarm and supervisory devices; or either normally open or Wire length: 6' (15.24 cm) minimum. normally closed security devices. The module has a single panel-controlled LED. MMF-302 Interface Module NOTE. The MDF-300 provides two Class B (Style Y) IDC circuits ONLY. Class A (Style Z) IDC circuits are NOT supported in any • Supports compatible two-wire smoke detectors. application. • Supervises IDC wiring and connection of external power MDF-300 SPECIFICATIONS source. High noise (EMF/RFI) immunity. Normal operating voltage range: 15 to 32 VDC. • SEMS screws with clamping plates for ease of wiring. Maximum current draw: 5.1 mA (LED on). Page 2 of 6 - DF-52121:A - 6/11/07 Average operating current: 750 pA (LED flashing). The MMF-301 module is intended to be wired and mounted EOL resistance: 47K ohms. without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and Maximum IDC wiring resistance: 1,500 ohms. regulations. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Agency Listings and Approvals Dimensions: 4.5' (11.43 cm) high x 4' (10.16 cm) wide x In some cases, certain modules may not be listed by certain 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x approval agencies, or listing may be in process. Consult fac- 2.125' (5.398 cm) deep box. tory for latest listing status. MDF-300 AUTOMATIC ADDRESSING • UL:: S3705 The MDF-300 automatically assigns itself to two addressable ' ULC: CS3 points, starting with the original address. For example, if the • FM Approved MDF-300 is set to address "56", then it will automatically assign • CSFM: 7300-0075:185 itself to addresses "56" and "5T'. • MEA: 72-01-E NOTE: ones' addresses on the MDF-300 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use Product Line information the second address. MMF-300: Monitor module. CAUTION: Avoid duplicating addresses on the system. MMF-301: Monitor module, miniature. MMF-302: Monitor module, two-wire detectors Installation MDF-300: Monitor module, dual, two independent Class B cir- cuits. MMF-300, MMF-302, and MDF-300 modules mount directly to a standard 4' (10.16 cm) square, 2.125' (5.398 cm) deep, SMB500: Optional surface-mount backbox. electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- Architects'/Engineers' Specifications lions are provided with each module. All wiring must conform Specifications of these and all Fire•Lite products are available to applicable local codes, ordinances, and regulations. These from Fire•Lite. modules are intended for power-limited wiring only. 3 6 O I ~ ~ 3 CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING Face plate for MMF-300, MMF-302, and MDF-300 a~a o e B~ 3 a ® f Mounting Diagrams for standard-sized modules 01 DF-52121:A • 6/11 /07 - Page 3 of 6 Wiring Diagrams The following wiring diagrams are included: 1. MDF-300: Typical dual two-wire Style B initiating device circuit configuration. 2. MMF-301: Typical two-wire Style B initiating device circuit configuration. 3. MMF-300: Typical two-wire initiating circuit configuration, NFPA Style B. 4. MMF-300: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. 5. MMF-300: Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). 6. MMF-302: Interface two-wire conventional detectors, NFPA Style B. 7. MMF-302: Interface two-wire conventional detectors, NFPA Style D. 8. CRF-300: Relay control module used to disconnect a power supply. Figure 1 MDF-300 Typical dual two-wire Style B initiating device circuit configuration. T 'WI wo Initiating Device Circuits _ fL M TO Next - FROM Panel each powe Nimited to Device 230 pA max. 12 VDC max. MONITOR or Previous Device 47K EOL O MODULE Resists H v Communication Line ELR-47K 9 O 0 32 VDC maximum. 8 1 - Twisted-pair is 7 ivn 2 + recommended. 47K EOL 6 3 All shown wiring is supervised and power Resistor 5, 4 limited. ELR-47K °NE Connect modules to listed compatible C O O 0 Fireiite control panels only. • ANY NUMBER of UL Listed contact closure devices may be used. • DO NOT MW lire star inilfating, supervisory, or security devices on the same circuit. • Instal contact closure devices per manufacturers installation Instructions. 6720mtt.wml Figure 2 MMF-301 Typical two-wire Style B initiating device circuit configuration. To ? NEXT DEVICE UL LISTED BLACK ? RED Compatible MMF-301 Control 4 67881013 456789 Panel 3012 3 2101514 210 00 VIOLET ? YELLOW 47K EOL INCLUDED 96720wir1.wmf Page 4 of 6 - DF-52121:A • 6/11/07 NOTE. Wiring Diagrams this Page: MMF-300 • Connect modules to listed compatible Fire•Lite control • Any number of UL-listed contact closure devices may be panels only used. • All wiring shown is supervised and power limited. • DO NOT MIX fire alarm initiating, supervisory, or security • Install contact closure devices per manufacturers' installa- devices on the same circuit. lion instructions. Figure 3 MMF-300 Typical two-wire initiating circuit configuration, NFPA Style B. TO Next + FROM Panel Device orPrevious MONITOR Device 11o ieffnq Device Cason #DC) O MODULE NFPA Style B, power Imiled: Communks&m Line 230 pA max. Q 12 VDC max. O 33VDCmmdmum. 9 a 1 - Twisted-pair is 47K EOL 2 + recommended. Resistor 8 ELR-4TK 5 Communication Loss (op"W com"dion for panels which support this feature) O 00 FUTURE FEATURE 6720wir2.vmd Figure 4 MMF-300 Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. TO Next FROM Panel Device or Previous MONITOR Device Q MODULE 00 Communication Line 9 O 0 32 VDC maximum. a 1 - Twisted-pair Is EOL Resistor 7 ,ee 2 + recommended. is internal at terminals 8 & 9 5 4 Communication Loss (optional connedion for panels which support this feature) Q O D FUTURE FEATURE 6720.03.w f Figure 5 MMF-300 Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). TO Next - FROM Panel Initiating Device Circuit (1DC) Device or Previous NFPA Style B, power 6mk®d: MONITOR R Device 3301 A max. O 12 VDC max. O MODULE O \ Communication Line 14K Series Resistor a 0 32 VDC maxmum. 9 9 1 - Twisted-pair is 47K EOL a 7 i 2 + recommended. ELa -47K 5 45 4 -14- Communication Loss O E5 (optional connection for panels which support this feature) O O O O FUTUREFEATURE 672&w 4m-f DF-52121:A • 6/11/07 - Page 5 of 6 NOTE. Wiring Diagrams this Page: MMF-302 and CRF-300 • Connect modules to listed compatible Fire•Lite control • Detectors must be UL listed compatible with module. panels only. • Install detectors per manufacturers' installation instruc- • Terminal wiring must be power limited. tions. • DO NOT MIX fire alarm initiating, supervisory, or security • Power to the interface module must be externally devices on the same circuit. switched to reset the detectors. An CRF-300 relay control • DO NOT LOOP wire under terminals. Break wire run to module can be used to switch power from a standard provide supervision of connections. power supply; see Fig. 7 below. Figure 6 MMF-302 Interface two-wire conventional detectors, NFPA Style B. TO Next FROM Panel twice orprewrous INTERFACE Device O MODULE CommLlnkatw Lone 32 9 0 0 V~n k la um. . 6 1 + 3.91K EOL 7 2 Resistor 6 3 Listed Battery Backup (included) 5 4 + switched DC C 112143-10 power sWly. Q O TO Optional Branch Circuit interface Module voltage U Module supervises Figure 7 MMF-302 Interface two-wire conventional detectors, NFPA Style D. TO Next FROM Panel Device Devicekws Device INTERFACE MODULE Communication Line v 32 VDC maximum. Twisted-pdr is 9 C p recommended. 3.9K EOL Resistor 8(5 1 + Qnctuded) required 7- 2 Listed Battery Backup at terminals 8 4 9 6 3 + A2143-10 5 4 switched DC pourer supply. P Q O 00 At Optional Branch Circuit TO Neil Interface Module Module supervises supply voltage and detector loop. 6720wir6.wmf Figure 8 CRF-300 Relay control module used to disconnect a power supply. TO Next Z FROM Panel twice orprevious RELAY Device DC POWER CONTROL SUPPLY MODULE C~ Listed for Fire e V Communication Line Protection with 32 VDC maximum. Battery Backup 6 1 o - Twisted-pair is 7 2 recommended. 6 3 5;1-4 L.. ADDRESS Q O O 6720wi,7.wmf LiteSpeedlm is a registered trademark of Honeywell International Inc. 02007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 90g, This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. Ali 1<MNR All specifications are subject to change without notice. 1911ITT SYSTEMS Made in theU.S.A. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 6 of 6 - DF-52121:A • 6/11/07 z o W 00 I f simmiawo < 3 s s# I Q 0 ~d of Mn d > N a' O Z LLL WZ o3 oW C0 f _dW. o, z OQ v U .<.<,. WN) w O O f- ^ !(HOCINM)l'" uJ o 30Y 01S 08 Q Z Z o 3NIHOYW :0Yt QYN (10 • tl1 Z Q z 30YN0Ydr ' U) v M3N r. O r~ 0u 0,ouli 0~ O 5 0 w o W 00 Z 'c" 1 00 O U Z [Y Sow n- m H CLO. W z~a,1av f Q Z, LL110 "(D LL1 O o~0 ~U Z woo 0 00 0 -J Z IUZ w . r? yz a ~z 300 M3 N) m a-, LL- Lo ~ ~ U h 04 -,z L p i LL. X ZN{ c~ •-sue ,L\ o i v~°~ ti --w cl! ~Op~wq~V~zo C-1) c G R, r. C~. n,S J w v lqb) CV ~1 Q `-I9 ^\P ICATION NO. DO, aOib~ C~J FIRE DETECTION SYSTEM RECEIVED C7 FIRE PROTECTION SYSTEM } ? DISAPPROVED NOV 3 O 2007 , O APPROVED AS NOT ` BUILDING DIVISION DUBLIN APPROVED Z