Loading...
07201245 Permit File Office CITY OF DUBLIN =Dj cif Building Standards •,5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 AUG 0 2007 WTFD: (614) 652-3920 $my FIRE PROTECTION PERMIT APPLICATION r l' Application Date g to ' U 7 Bldg. App. # &7 - go<« Fire Protection App. # l~ / rfV PROJECT INFORMATION Project Address 6 Ap -,JTu0 ,A'y Et , Su i TE 2i~ Project Name W 0 ~D ~r"'y ~y Owner/Tenant Contact Name CE4a-2L-F5 K-J H L M A fJ Telephone F~ (4 2~~ I 7£~ 10 APPLICANT INFORMATION Fire Protection Contractor t i°w oo Cl~ Address 36o VA-4-Ley U i i;~w l~2 C-pt-tjM 9L)5 ot+ d-31, 4-Telephone '14 -4-4 State Certificate Number 5 2S ivZ> z. Dublin Registration Number jZv 61 Installer Name ~y~l n~ %A yS i~~ State Certificate Number ~4 - ?S • 3 i 9 3 SCOPE OF WORK (Mark One) New Replace Repair Alteration FIRE DETECTION AND ALARM SYSTEM (Number of Each) Detectors Strobes Horns Z Fire Alarm Boxes Other SUPPRESSION SYSTEM (Number of Each) Standpipes On Site Water Piping Sprinkler Heads Limited Area Other FEES FIRE DETECTION OR SUPPRESSION PERMIT PROCESSING FEE $60.00 LOW VOLTAGE PERMIT (DETECTION ONLY) $30.00 Minimum fee plus $20.00 each 1,000 sq ft or fraction thereof over 1,000 sq ft OUTSIDE PLAN REVIEW SERVICES (EXAMINER'S FEE AS CHARGED) STATE SURCHARGE (3%) TOTAL FEE DUE O This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. This permit conveys no right to open any street, alley or sidewalk or any part thereof, nor to make any connection to a water main. Signature of Licensed Contractor DATE Print Name f'A b>fFKA-i DATE FOR OFFICIAL USE ONLY Review Comments: e i%e S~ P ex/c /fC a io u q s F,?e 7e- Cie%c~v- akve Ns1C eK7'A?a4r p-qA4-1 ii7 f/e -ferper /o4y o Pr 7.2Se-//4 ~yf A'OLC-Cfioil o f or/?c A/o/A Cargo / 4/4it6,) x Fire Department: Fi%P Date: 00,91e Plans Examiner: l Date: °1 to 0 Issued by CBO:~ Date: S CITY OF DUBLIN Division of Building Standards •-5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00201245 Date 9/11/07 Property Address . . . . . . 4995 BRADENTON AV Parcel Number: 273-004826 Alternate Address: LLEWELL FARMS WEST Tenant nbr, name . . . . . . WORLD ENERGY DETECTION Application type description FIRE PROTECTION Property owner . . . . . . . RENNOB INC Contractor . . . . . . . . . CAPITAL FIRE PROTECTION CO. Permit . . . . . . FIRE DETECTION PERMIT Additional desc . . Permit Fee . . . . 60.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 60.00 Special Notes and Comments CONTACT WASHINGTON TOWNSHIP FIRE PREVENTION FOR INSPECTIONS AT 766-0857 Other Fees . . . . . . . . . SURCHARGE FEE - FIRE 1.80 Fee summary Charged Paid Credited Due Permit Fee Total 60.00 .00 .00 60.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 1.80 .00 .00 1.80 Grand Total 61.80 .00 .00 61.80 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. July 8, 2004 DF-52301 • D-025 Fire-LIWALarms FOPS-24FS6 24 Volt, 6 Amp Remote Power Supply www.firelite.com Section: Power Supplies/Accessories GENERAL California The FCPS-24FS6 is a compact, cost-effective, 6-amp re- L FM LaMStatearshal le mote power supply with battery charger. The FCPS-24FS6 ® 7315-0075:206 may be connected to any 12- or 24-volt Fire Alarm Control APPROVED Panel (FACP) or may stand alone. Primary applications LISTED M EA, include Notification Appliance (bell) Circuit (NAC) expan- S2424 w O 2007 sion (to support ADA requirements and NAC synchroniza- 219-02-E A06 tion). or auxiliary power to support 24-volt system acces- sories. The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits con- I f~ 1 I' ~i . figured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS- 24FS6 also contains a battery charger capable of charg- ing up to 18 Amp Hour batteries. FEATURES • UL Listed NAC Synchronization using System Sensor, - Wheelock or Gentex (Commander Series) appliances. • Cascadable up to 10 power supplies (four with Gentex) with strobe timing maintained. • Operates as a sync follower or a sync generator (default). * See note on reverse side. • Contains two, fully-isolated input/control circuits (trig- gered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on (stand- alone mode]). • Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF- 300) for alarm activation. • Four Class B (Style Y) orfour Class A (Style Z) (with ZNAC- AC trouble report selectable for immediate or 8 hour 4 Module) Notification Appliance Circuits. delay. • 6.0 A full load output (3.0 A maximum per circuit) in NAC Works with virtually any UL 864 fire alarm control which expander mode (UL 864). utilizes an industry-standard reverse-polarity notifica- • 4.0 A continuous output in stand-alone mode (UL 1481). tion circuit (including unfiltered and unregulated bell • In stand-alone mode, output power circuits may be power). configured as resettable (reset line from FACP required) Requires input trigger voltage of 9.0 - 32 VDC. or non-resettable or a mix of two and two, Self-contained in compact, lockable cabinet (15" [38.1 • Fully regulated and filtered power output (optimal for cm] H x 14.5" [36.8 cm] W x 2.75" [7.0 cm] D). powering four-wire smoke detectors, annunciators and includes integral battery charger capable of charging up other system peripherals requiring regulated/filtered to 18 AH batteries. Cabinet capable of housing 7.0 AH power). batteries. • Power-limiting technology meets UL power-limiting re- Battery charger maybe disabled via dip switch for appli- quirements. cations requiring larger batteries. • Form-C normally-closed trouble relay. Fixed, clamp-type terminal blocks accommodate up to • Fully supervised power supply, battery and Notification 12 AWG (3.1 mm') wire. Appliance Circuits. • Selectable earth fault detection. This o Alarms is a Honeywell company. '~O ~oo~ This document is not intended to be used for installation purposes. We try to keep our product ~ information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. K- -16 a I =9 I =6 .1 For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. ENGINEERING A MMURIMIRING Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-52301 07108/04 - Page1 of 2 ( STANDARDS and CODES Example 2 The FCPS-24FS6 complies with the following standards: Use the FCPS-24FS6 to expand auxiliary regulated 24 volt • NFPA 72 National Fire Alarm Code. system power up to 4 amps. Both non-resettable and • UL 864 Standard for Control Units for Fire Alarm Sys- resettable power options are available. tems (NAC expander mode). Resettable outputs are created by connecting the resettable • UL 1481 Power Supplies for Fire Alarm Systems output from the FACP to one or both of the FCPS-24FS6 (stand-alone mode). inputs. SPECIFICATIONS Example 3 Use addressable control modules to activate the FCPS- Primary (AC) Power 24FS6 versus the FACP Notification Appliance Circuits. This • FCPS-24FS6: 120 VAC 60 Hz, 3.2 A maximum typically allows for mounting the FCPS-24FS6 at greater • Wire size: minimum 14 AWG (2.0 Mm 2) with 600V insu- distances" away from the FACP while expanding system lation. architecture in various applications. Control Input Circuit In this example, an addressable control module is used to • Trigger Input Voltage: 9.0 to 32 VDC. activate the FCPS-24FS6 and an addressable monitor • Trigger Current: 2.0 mA (16 - 32 V). module is used to sense FCPS-24FS6 trouble conditions. (per input) 1.0 mA (9 - 16 V). Local auxiliary power output from the FCPS-24FS6 pro- Trouble Contact Rating vides power to the addressable control module. • 5.0 A at 24 VDC. Auxiliary Power Output *Fire•Lite's MS-9200, MS-92000D, (198-point) or MS-9600 (636- • Specific Application Power - 500 mA maximum. point) addressable FACPs have the capability of locating control OutputCircuits and monitor modules up to 10,000 feet (3048 m) away. • +24 VDC filtered, regulated. • A maximum for any one circuit. Sync Follower/Generator Note: In some installations, it 3.0 • 4.0 A maximum total continuous current for all outputs is necessary to synchronize the flash timing of all (Stand-alone mode). strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses • 6.0 A maximum total short-term current for all outputs on the NAC power, which are created by a Fire Alarm (NAC Expander mode). Control Panel such as the Fire•Lite MS-9600. When Secondary Power (Battery) Charging Circuit installed at the end of a MS-9600 NAC wire run, this • Supports lead-acid batteries only. power supply can track (i.e. "follow") the strobe synchro- • Float Charge Voltage: 27.6VDC. nization timing pulses on the existing NAC wire run. This Maximum Charge Current: 1.5 A. maintains the overall system flash timing of the addi- • Maximum Battery Capacity: 18 AH. tional strobes attached to this power supply. ORDERING INFORMATION When this power supply is configured (via DIP switch settings) as a "sync follower," this supply's NAC outputs FCPS-24FS6 Remote charger power supply (120 track the strobe synchronization pulses present at this VAC). Includes main printed circuit supply's sync input terminal. The pulses are originated board, transformers, red enclosure, and from an upstream FACP or other power supply. installation instructions. When this power supply is configured (via DIP switch settings) as a "sync generator," this supply's sync input FCPS-2456RB Replacement mother board. terminal are not used. Rather, this power supply is the PN 90286 FCPS-24F Module Mounting Kit originator of the strobe synchronization pulses on this power supply's NAC outputs. In "sync generator" mode, ZNAC-4 Class A (Style Z) NAC option module the sync type (System Sensor, Wheelock, or Gentex) is A77-7168 12/24 VDC end-of-line relay for selectable via DIP switch settings. monitoring 4-wire smoke detector power. BAT-1270 Battery, 12 volt, 7.0 AH (two required). APPLICATIONS Example 1 Expand notification appliance power an additional 6.0 amps. Use up to 4 Class B (Style Y) outputs or 4 Class A (Style Z) outputs (using the ZNAC-4). In this example, the FACP notification appliance circuits will activate the FCPS-24FS6 when reverse polarity acti- vation occurs. Trouble conditions on the FCPS-24FS6 are sensed by the FACP through the Notification Appli- ance Circuit. Page 2 of 2 - OF-52301 07/08104 00 COOPER Wheelock Series MT and MT Strobe Multitone Electronic Appliances SERIES MT STROBE MT4-115-WH SERIES MT-12/24 Description: Features: The Wheelock Series MT and MT Strobe Multitone electronic Approvals include: UL Standard 1971, UL Standard appliances offer a choice of eight (8) nationally and internationally 464, California State Fire Marshal (CSFM), New York City recognized alerting sounds: Horn, Bell, March Time Horn, Code- (MEA), Factory Mutual (FM) and Chicago (BFP) See 3 Tone, Code-3 Horn, Slow Whoop, Siren or Hi/Lo Tone. The approvals by model in Specifications and Ordering Code-3 Horn and tone patterns are engineered to comply with Information NFPA/ANSI Temporal Pattern specifications without requiring Designed to meet or exceed ADA/NFPA/UFC/ANSI additional equipment. With MT and MT Strobe appliances, one Standards and Accessibility Guidelines alarm appliance meets most of your signaling needs. The MT strobes can be synchronized using the Wheelock SM, DSM Sync Complies with OSHA 29, Part 1910.165 Modules or the PS-24-8MC Power Supply with the Wheelock Series MT appliances have IN and OUT wiring patented Sync Protocol. terminations that accept two #12 to #18 American Wire Gauge (AWG) wires at each terminal. Inputs are The MT Strobes are designed forADA applications while meeting polarized for compatibility with standard reverse polarity or exceeding the latest requirements of NFPA 72, ANSI 117.1, type supervision UFC and UL Standard 1971 as well as meeting ADA requirements One alarm appliance with (8) eight selective signals to concerning photosensitive epilepsy. provide superior sound penetration for various ambient Each MT and MT Strobe appliance has two installer selective and wall conditions with two field selectable sound output sound output levels: STANDARD dBA and HIGH dBA. Non-strobe levels versions provide selectable voltage capability in one unit, 12VDC Code-3 Horn and Tone meet ANSI/NFPA temporal pattern or 24VDC. Strobe versions are specific for either 12VDC or 24VDC for standard emergency evacuation signaling and all models may be used with filtered or unfiltered (full-wave- Audible and strobe can operate from a single NAC circuit rectified) input voltages. Separate input terminals are available, or from separate NAC circuits with any of the (8) eight shunt wires are provided to enable both tone and strobe to operate audible sounds simultaneously from a single input. • MT Strobe models are available with Wheelock patented The Series MT Multitone Strobe appliances are UL Listed for MCW Multi-Candela strobes with field selectable c indoor wall mount applications under Standard 1971 for Signaling andela settings at 15/30/75/110cd or with single candela Devices for the Hearing Impaired and under Standard 464 for 1575cd strobes. The strobes can be synchronized using Audible Signaling Appliances. Wheelock sync modules or power supplies with built in Sync Protocol • Selectable input voltage on non-strobe versions. Strobe versions are factory set for either 12 or 24VDC, with wide- Listed voltage range, filtered (DC) and FWR • No additional trimplate required for flush mounting For Weatherproof MTWP See Data Sheet S9004 U IfW YpIK nc<m <@> ® MFA ,.4 APPROVED E5946 151-92-E 7135-0785:118 (MT4) 7125-0785:155 (MT) 7125-0758:156 (MTWP) NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range" (16-33v for 24VDC units and 8-17.5v for 12VDC units). Regulated Voltage Range is the newest terminology used by UL to identify the listed voltage range. • All candela ratings represent minimum effective Multitone Strobe intensity based on UL Standard 1971. • MT Strobe models are UL Standard 1971 Listed for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% ±2%. The MT-12/24, MTWP and MT4 models and listed for outdoor use at -31 °F to 150°F (-35°C to 66°C) and maximum humidity of 95% (See Data Sheet S9004 or Installation Instruction Sheet P84150 for more detail on MTWP). MTWP and MT4 strobes are listed under UL 1638. • MT Audible is UL Standard 464 Listed. Alarm Tones TONE ALARM TONES PATTERN DESCRIPTION HORN BROADBAND HORN (Continuous) BELL 1560 Hz MODULATED (0.07 sec. ON/Repeat) MARCH TIME HORN (0.25 sec. ON/0.25 sec. OFF/Repeat HORN CODE-3 HORN HORN (ANSI S3.41 Temporal Pattern) CODE-3 TONE 500 Hz (ANSI S3.41 Temporal Pattern) SLOW WHOOP 500-1200 Hz SWEEP (4.0 sec. ON/0.5 sec. OFF/Repeat) SIREN 600-1200 Hz SWEEP (1.0 sec. ON/Repeat) HI/LO 1000/800 Hz (0.25 sec. ON/Alternate) Table 1: dBA and Current Ratings for Multitone Audible Portion RMS Current (amps) dBA @ 10ft (UL Reverberant) 24 VDC 12 VDC 120 VAC 24 VDC 12 VDC 120 VAC HI Output STD Output HI Output STD Output HI STD Output Output HI STD HI STD HI STD @ 24 UL @ 24 UL @ 24 UL @ 24 UL UL UL Output Output Output Output Output Output VDC max* VDC max* VDC max* VDC max* max* max* Horn 0.074 0.108 0.033 0.044 0.145 0.176 0.023 0.034 0.050 0.042 92 87 90 77 85 82 Bell 0.040 0.053 0.018 0.024 0.077 0.095 0.014 0.020 0.041 0.039 86 80 85 69 82 75 March Time 0.067 0.104 0.033 0.038 0.109 0.142 0.023 0.034 0.050 0.040 89 84 89 74 85 79 Horn Code-3 Horn 0.069 0.091 0.026 0.035 0.100 0.142 0.023 0.034 0.050 0.042 88 83 88 73 82 75 Code-3 Tone 0.061 0.075 0.026 0.035 0.088 0.105 0.015 0.021 0.042 0.040 85 80 84 70 79 75 Slow Whoop 0.069 0.098 0.028 0.037 0.100 0.142 0.025 0.035 0.050 0.042 90 89 89 75 85 82 Siren 0.080 0.104 0.027 0.036 0.122 0.152 0.021 0.030 0.045 0.041 89 84 89 75 85 82 1-11/1-0 0.044 0.057 0.020 0.026 0.089 0.114 0.018 0.026 0.042 0.039 86 81 86 71 82 79 I Note: If the strobe and audible operate on the Table 2: Strobe Current Ratings, came circuit, add the strobe current from Table 2 RMS Current (amps) to the audible current from Table 1. Model MT-121575 MT-241575 MTWP-2475 MT-24MCW * RMS current ratings are per UL average RMS Candela 1575cd 1575cd 180cd 15cd 30cd 75cd 110cd method. UL max current rating is the maximum RMS @ 24VDC 0.152 0.060 0.094 0.041 0.063 0.109 /,0.140 current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at UL max* 0.255 0.090 0.138 0.060 0.092 0.165 0.220 the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for24v units). For unfiltered FWR ratings, see installation instructions. Wiring Diagrams (for all models) MT SIGNAL AUDIBLE SIGNALAND STROBE AUDIBLE SIGNALAND STROBE OPERATE OPERATE INDEPENDENTLY IN UNISON. RED AND BLACK SHUNT-WIRES r ou ' } { zd,xr ARE SUPPLIED. rltEOR x_a F5 1 24Nr + + napiN T NEKT xn3s e©uc FRC + TO NEXT PRECEDIf [G <a; P ° R EQLR 40 purr aw + - ORFACPOR 6aCk - APPLIANCE FA: P .a SIGNAL ITri085 AUDiaLI mllec- Aua Specifications and Ordering Information Model Order Input Rated Mounting Agency Approvals Number Code Voltage Candela Options*** UL MEA CSFM FM BOP MT-12/24-R 5023 12/24 - D,E,F,L,M,O,P,R X X X X X MT-12124-W 5024 12/24 - D,E,F,L,M,O,P,R X X X X X MT-241575W-FR" 8422 24 15 (75 on AXIS) D,E,F,L,M,O,P,R X X X X MT-24MCW-FR 3301 24 15/30175/110 D,E,F,L,M,O,P,R X * X MT-24MCW-FW 3303 24 15/30(75/110 D,E,F,L,M,O,P,R X X MT-121575W-FR° 8421 12 15 (75 on AXIS) D,E,F,L,M,O,P,R X X X X MT-121575W-NW 9747 12 15 (75 on AXIS) D,E,F,L,M,O,P,R X X X X MTWP-2475W-FR** 8420 24 180 @ 77°F (25°C) M X X X X MTWP-2475W-NW** 9744 24 180 @ 77°F (25°C) M X X X X MT4-115-R 6223 120 VAC - D,E,J,K,N,O,R X X X X X MT4-115-S 6142 120 VAC - D,E,J,K,N,O,R X. X X X X MT4-115-WH-VFR"" 6224 120 VAC 15 D,E,J,K,N,O,R X X X X X MT4-12/24-R 5308 12/24 - D,E,J,K,N,O,R X MT4-12/24-S 7997 12124 - D,E,J,K,N,O,R X NOTE: **MTWP-2475W is Weatherproof and rated for 180 cd @ 77°F (25°C). See Data Sheet S9004 or installation Instruction P84150. ***For additional information on mounting please refer to Data Sheet S7000. # 1575 strobes are UL Listed for 15cd with 75cd on AXIS. *Pending Series WH Strobe is listed for UL Standard 1638 only. See Instruction Sheet P83160. ~hWARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" P82467 MT-12124, P84155 MTw/Strobe P84150 MTWP WEATHERPROOF "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS DO UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BYALLAPPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. • FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. • FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUAT lON,WHiCH COULD RESULT IN PROPERTi DAMAGE AND SERIOUS INiURY OR DEATH TO YOU AND/OR OTHERS. • CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The notification appliance shall be a Wheelock Series MT audible/visual appliance or equivalent. Notification appliance shall be electronic and use solid state components. Electromechanical alternatives are not approved. Each electronic appliance shall provide eight (8) field selectable alarm tones. The tones shall consist of. HORN, BELL, MARCH TIME HORN, CODE-3 HORN, CODE-3 TONE, SLOW WHOOP, SIREN and HI/LO. Tone selection shall be by durable dip switch assembly and not clips or jumpers. The Multitone Audible appliance shall be UL Listed under Standard 464 for Audible Signal Appliances. The audible and the strobe shall be able to operate from a single NAC circuit while producing any of these tones. The appliance shall provide two output sound levels: STANDARD and HIGH dBA. The HIGH dBAsetting shall provide a minimum 5 dBAincrease in sound outputat nominal voltage. The HIGH anechoic dBA measurement at 10 feet at the alarm HORN SETTING shall be 99 dBA minimum. Operating voltages shall be either 12 VDC or 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall have provisions for standard reverse polarity type supervision and IN/OUT field wiring using terminals that accept #12 to #18 AWG wiring. Combination audible/visual appliances shall incorporate aXenon flashtube enclosed in a rugged Lexan® lens or equivalentwith solid state circuitry. Strobe shall produce a flash rate of one (1) flash per second minimum over the voltage range. The MT strobe intensity shall be rated per UL and Listed under Standard 1971 for Signaling Devices for the Hearing Impaired for 1575cd multi-candela with field selectable 15/30/751110 candela settings. The 1575 candela strobe shall be specified when 15 candela or with 75 candela intensity on-axis is required. Strobe Models shall incorporate circuitry for synchronized strobe flash and shall be designed for compatibility with Wheelock SM and/or DSM Sync Modules or Wheelock's Power Supplies with Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the module fails to operate (i.e., contacts remain closed), the strobes shall revert to a non-synchronized default flash rate. Strobe activation shall be via independent input or from the same input circuit as the audible. The combination audible/visual appliances shall be installed indoors and may be surface or flush mounted. They shall mount to standard electrical hardware requiring no additional trimplate or adapter. The aesthetic appearance shall not have any mounting holes or screw heads visible when the installation is completed. The appliance shall be finished in a textured red color. The Series MT-12/24, MTWP and MT4 appliances may be installed indoor or outdoor with the proper back box. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. 00 COOPER Wheelock 273 Branchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732) 222-2588 3 YEAR WARRANTY www.cooperwheelock.com Made in USA S2000 MT 06/06 00 COOPER Wheelock Series RSS and RSSP Strobes and Strobe Plates =1R~ -7 1 Series RSS Series RSS Series RSSWP RSS Round Description Features The Wheelock patented Series RSS Strobe Appliances and Approvals include: UL Standard 1971, New York City (MEA), Series RSSP Strobe Plates have lower current draw while California State Fire Marshal (CSFM), Factory Mutual (FM), and maintaining outstanding performance, reliability and cost Chicago (BFP) See approvals by model in Specifications and effectiveness. Theseversatile applianceswill satisfy virtu ally all Ordering Information requirements for indoor, wall or ceiling mount applications. ADA/NFPA/UFC/ANSI compliant. Meets OSHA 29 Part Strobe options for wall mount models include 1575 or the 1910.165 Wheelock Patented MCW multi-candela strobe with field Wall mount Multi-Candela models are available with Field selectable candela settings of 15/30/75/110cd or the high Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. intensity MCWH strobe with field selectable 135/185cd. Single Candela models are available in 1575cd Ceiling mount models include the patented MCC multi-candela Ceiling mount Multi-Candela models are ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable available with field selectable candela settings of 15/30/75195cd 115/177cd. or 115/177cd. (Round or Square) All models may be synchronized using the Wheelock SM, Strobes produce 1 flash per second over the DSM Sync Modules or the PS-24-8MC Power Supplies with regulated voltage range the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes 12 and 24 VDC models with wide UL "Regulated Voltage" us- in the field of view. Wheelock's synchronized strobes offer an ing filtered (DC) or unfiltered VRMS input voltage easy way to comply with ADA recommendations concerning Synchronize using the Wheelock sync modules or power sup- photosensitive epilepsy as well as meeting the requirements plies with built-in sync protocol of NFPA 72. Fast installation with IN/OUT screw terminals using #12 to #18 The Wheelock Series RSS Strobes employ a Patented Integral AWG wire Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification For Weatherproof Series RSS See Datatsheet S9004 Appliance Trimplate) may be used. It provides an additional.65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, homs, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. yn~~ FM u L n~fM APPROVED MEA 55391 151-92-E 7125-0785:141 7300-0785:154 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (O°C to 49°C) and maximum humidity of 93% 2%). • Series NH homs are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP -Wall Mount Ceiling Mount RSS/RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH 24VDC Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSS/RSSP RSS/RSSP 24VDC Wall Mount * RMS current ratings are per UL average RMS method. UL max current Models 121575W rating is the maximum RIMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at UL max* 0.255 the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Wiring Diagrams # Horns AH, NH, HS SERIES RSS/RSSP APPLIANCE Motor Bells MB-G6/G10 FROM + TO NEXT? Speakers ET-1010/1080, E70, ET70 PRECEDTNC-O - _BPPLIANCE? APPLIANCE, SYNC? OR EOLR? Chimes CH70 MODULE, POYJER? SUPPLY OR FACP? - SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM k1? DSMD sync? S?ROBEO +00 Strobe NAC Cir. O+? PISS. RSS NACO SYNC-10 F? m ? CIRCUITO _ C OU?o .OUT 10 DSM 020 + IN 10 P.SS ASS RSS A? C•~nC? \ Strobe NAC C`l MINUS 10 P.SS RSSC O FACPEZZ 0+0 DIB•F C11 0 ; DSM 9 30 NINVS 20 S' '1l~ RSS' RSS y~ + IN 20 Rss RSS PISS Strobe NAC C r STROBEO ,TACO + OUT 2:1 CIRCUIT? DSM Interconnecting W4 .ring shown. Maximum off] P.ETLRNO twenty (20)0 STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON SERIES RSS/RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT TO NEXT? SM? FROMD + + PPLIANCEF F? +E8TROBE0 PRECEDINGO - OR EOLRO -ESTROBED APPLIANCE, SYNC? A? StrobeO RSS RSS MODULE POUiERO LJ haco i Circuit[ SUPPLY OR FACP? 0 ~-~C? : ,6 bieo STROBEQ AUDDIBLEO UE P11 aOuLdRiA7 STROBE/PLATE ASSEMBLY SERIES RSS/RSSP APPLIANCES SYNCHRONIZED AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY WITH PS-12/24-8CP or PS-12/24-8MP 'RO.a Series PS-12/24-SMPO PRECEDINGp +DO APPL:R-D APPLIANCE ORp _O -O CR EOLF~ FACRp ASO A550 GUT?UPS? EOLRO 1-4? eROra - 1 - - - - - I-~NGYTp F? 4-CLASso PRECEDIN,p OBE ORO B.O STROBE, SYNCO U-- Tj l f - RO A? GPO MODULE, PORERO ASO ASsO SPPL: OR FAO D 2-CL ASSO 1 „A +a re P11 STROBE] APPLIANCEO - ASO RS SO ° For detail using SM or DSM Sync Module refer to Data Series PS-12/24-8P! Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. Forwiring information on the power supplies refer to Installation Instructions P84515 for PS- 12/24-8CP and P84333 for PS-12/24-8MP. Specifications and Ordering Information Order Wall Ceiling Non- Strobe 24 12 Color Color Square Agency Approvals Model Code Mount Mount Sync Candela VDC VDC RED WHITE Mounting Options*** or UL MEA CSFM FM BFP Round RSS-24MCW-FR 940 X - X 15/30/75/110 X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30/75/110 X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FR 7471 X - X 15 (75 on Axis) X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FW 7788 X - X 15 (75 on Axis) X X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FR 7476 X - X 15 (75 on Axis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15 (75 on Axis) - X X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCC-FW 3158 X X 15/30/75/95 X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS-24MCC-FR 3157 X X 15/30175/95 X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS-24MCCR-FW 3160 X X 15/30/75/95 X - X B,D,E,F,G,H,J,N,O,R,X Round X X X X RSS-24MCCH-FW 3461 X X 115/177 X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS-24MCCHR-FW 3463 - X X 115/177 X - X B,D,E,F,G,H,J,N,O,R,X Round X X X X RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS-24MCWH-FW 3464 X X 1351185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSSWP-2475W-FR** 9013 X - X 180@ 77-F X X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X 75@-31-F RSSWP-2475W-FW** 3034 X - X 180@ 77-F X X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X 75@ -31 °F RSSP-121575W-FR 7798 X - X 15 (75 on Axis) - X X - D,E,Z Square X X X X X RSSP-24MCW-FR 9402 X - X 15/30/75/110 X X - D,E,Z Square X X X X X RSSP-241575W-FR 7793 X - X 15 (75 on Axis) - - X - D,E,Z Square X X X X X *PENDING All models sync with Wheelock SM, DSM or PS-12/24-8CP or PS-12/24-8MP. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second overthe Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexang) lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30175/110cd or 135/185cd for wall mount and 15/30/75/95cd or 1151177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or the Wheelock PS-24- 8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 1,00mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mountto either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. COOPER Wheelock JJr, *"wri 273 Branchport Avenue Long Branch, NJ 07740 t7~' 13~~5 Phone: (800) 631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732) 222-2588 3 YEAR WARRANTY www.cooperwheelock.com Made in USA S0410 RSSIRSSP 07107