Loading...
07201634 Permit File CITY OF DUBLIN LmIC@ REC ffl\ttff Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 NOV 2 1 2007 WTFD: (614) 652-3920 BUILDING DIVISION FIRE PROTECTION PERMIT APPLICATION CITY OF DUBLIN Application Date 111211C)? _ Bldg. App. # Fire Protection App. # c-4, ao t'o PROJECT INFORMATION Project Address 18 r"lc4er. to/4(C -S 4' h f /abrz Project Name (e `O~ %1 Ai/ L-Owner/Tenant Contact Name Telephone APPLICANT INFORMATION _ C Fire Protection Contractor VFt' r , r-2 r ~_5 r en-5 Address 2 7 Ci et C /J'4 K2 T I_n 5' Telephone 4 -.5Z 2 922. State Certificate Number rP5C"R2 10 CJ Dublin Registration Number 67- 2174 Installer Name c F4 w: State Certificate NumberT45-/ /0 P SCOPE OF WORK (Mark One) New _ Replace Repair Alteration FIRE DETECTION AND ALARM SYSTEM (Number of Each) Detectors Strobes Horns Fire Alarm Boxes Other SUPPRESSION SYSTEM (Number of Each) Standpipes On Site Water Piping Sprinkler Heads v~ Limited Area Other FEES FIRE DETECTION OR SUPPRESSION PERMIT PROCESSING FEE $60.00 LOW VOLTAGE PERMIT (DETECTION ONLY) $30.00 Minimum fee plus $20.00 each 1,000 sq ft or fraction thereof over 1,000 sq ft OUTSIDE PLAN REVIEW SERVICES (EXAMINER'S FEE AS CHARGED) STATE SURCHARGE (3%) .$o TOTAL FEE DUE l0\ . PLO This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. This permit conveys no right to open any street, alley or sidewalk or any part thereof, ncrr to make any connection to a water main. Signature of Licensed Contractor DATE _~4 Print Name DATE FOR OFFICIAL USE ONLY Review Comments: The sor~i,KlPr g/~ei'~fion alre?cv1nA Ineez& f1~4Sh~narb12 owr sh» fi ' DPp,?I-A eye aAorcvn Fire Department: Date: Plans Examiner: Date: 677 Issued by CBO: Date: J2'Y 1 7 CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00201634 Date 12/03/07 Property Address . . . . . . 485 METRO PL S Parcel Number: 273-004290 Alternate Address: METRO CENTER Tenant nbr, name . . . . . . COLONIAL LIFE SUPPRESSION Application type description FIRE PROTECTION Property owner . . . . . . . CB RICHARD ELLIS Contractor . . . . . . . . . VFP FIRE SYSTEMS Permit . . . . . . FIRE SUPPRESSION PERMIT Additional desc . . Permit Fee . . . . 60.00 Plan Check Fee .00 Issue Date . . . . 12_lo-D 7 Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 60.00 Special Notes and Comments CONTACT WASHINGTON TOWNSHIP FIRE PREVENTION FOR INSPECTIONS AT 766-0857 Other Fees . . . . . . . . . SURCHARGE FEE - FIRE 1.80 Fee summary Charged Paid Credited Due Permit Fee Total 60.00 .00 .00 60.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 1.80 .00 .00 1.80 Grand Total 61.80 .00 .00 61.80 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. September 6, 2007 Sprinkler 54a RAGE@ STANDARD AND N I KI W*j QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com 1. DESCRIPTION " Viking Mirage" Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- ^ profile cover assembly that provides up to 1/2" (12.7 mm) of vertical adjustment. TheN two-piece design allows installation and testing of the sprinkler prior to installation of x' the cover plate. The "push-on", "thread-off"design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 LPC Approved: Ref. No. 096e/12 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 Refer to the Approval Chart on page 54c and Design Criteria on page 54d for cULus Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar) Viking Technical Data may be found on Maximum Working Pressure: Sprinkler VK463 is rated for use with water The Viking Corporation's Web site at working pressures ranging from the minimum 7 psi (0.5 bar) up to http:ihvww.vikinggroupinc.com. 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) The Web site may include a more recent sprinklers can be identified by locating "250" stamped on the deflec- edition of this Technical Data Page. tor. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric*) 'Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Patents Pending Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-C51000 for Sprinkler VK463 Deflector Pins: Nickel Alloy for Sprinkler VK462 Stainless Steel UNS-S30300 for Sprinkler VK463 Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-C51000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F_103005 Replaces page 54a-e, dated August 9, 2007. (Added FM Approval.) t Sprinkler 54b September 6, 2007 IRAGE" STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. 13503A, 14697A, or HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix (°F/°C): 155°/68° = B, 175°/79° = D, 200°/93° = E For example, sprinkler VK463 with a 155 °F/68 °C temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter) or Base Part No. 13642 (3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M-/SW1004, Painted Ivory = M4SW1634, Painted Black = M-/SW1007 Temperature Suffix (°F/°C): 135°/57° UL (139°/59° FM) =A, 165°/74° = C For example, cover 13504 with a Polished Chrome finish and a 165 °F/74 °C temperature rating = 13504FC. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches*": A. Heavy Duty Part No. 14047W/B (available since 2006), or B. Light Duty Part No. 14031' (available since 2006) "Requires a Y:" ratchet (not available from Viking). -Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: five (5) sprinklers (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. September 6, 2007 Sprinkler 54c RAGE@ STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP N I KI W4j SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Sprinkler NPT Thread Nominal Maximum Overall Length Listings and Approvals' Base Part SIN Size K-Factor Water Working (Sprinkler Body) (Refer also to Design Criteria on page 54d.) Number' Inch mm U.S. metric= Pressure Inches mm cULus5 FM NYC6 LPCB C ~ 7 Standard Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) 2-3/16" 56 - AW1, BX1 - - 14697A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) 2-3/16" 56 - - - AW1, BX1 AW1, BX1 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) 2-3/16" 56 AW1, BX1 AW1, BX1 - - 14697A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) 2-3/16" 56 AW1, BX1 AW1, BX1 - - 13667A VK463 1/2" 15 5.6 80.6 250 psi (17.2 bar)' 2-3/16" 56 AW1, BX1 - AW1, BX1 Sprinkler Temperature Ratings Cover Plate Assembly Temp. Ratingse Finishes of the Cover Plate Assembly9 A - 155 °F (68 °C) W -135 "F (57 "C) UL Listed cover 13504 or 13642 (large 1 - Polished Chrome, Painted White, Painted diameter) FM Approved as 139 -F (59 -C) B - 175 °F (79°C) and 200 °F (93 °C) X - 165 "F (74 °C) cover 13504' or 13642' (large diameter) Ivory, or Painted Black Footnotes ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3The Water Working Pressure rating is stamped on the deflector. 4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. ' ( (Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 6 The 135/139 "F cover has an orange label. The 165 °F cover has a white label. 9 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) UL Red 139 °F (59 °C) FM Intermediate 175 °F (79 °C) 150 °F (65 °C) 165 °F (74 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) 165 °F (74 °C) Green Cover Plate Finishes: Polished Chrome, Painted White, Painted Ivory, or Painted Black Footnotes ' The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinkler 54d September 6, 2007 RAGE" STANDARD AND M:QFR CONCEALED PENDENT N11am I RINKLER VK462 AND HP PRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com cULus Listing Requirements: Mirage® Standard and Quick Response Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies up to and including Ordinary Hazard, Group II. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. FM Approval Requirements: Mirage® Concealed Pendent Sprinkler VK462 is FM Approved as a standard response standard spray sprinkler as indicated in the Approval Chart for hazard occupancies up to and including Ordinary Hazard, Group ll. For installation in accordance with the latest ap- plicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 or QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordi- nances, and standards, whenever applicable. CUSTpM QQ 9f Ce o n y NUU G4 v0 Identification of Custom Paint Color; All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates custom color and will have a representative sample Ca paint dot) of the paint on the label. Figure 1: Identification of Custom Paint Color for Concealed Covers September 6, 2007 Sprinkler 54e RAGE" STANDARD AND NIKI QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Sprinkler Wrench Sprinkler Flat 2-1/4' (57,2 mm) Frame diameter opening Arms is required in the ceiling. _ Sprinkler and Adapter Assembly (Protective Cap is removed for installation use Wrench 1403131-a) NEVER install the sprinkler by applying the installation Sprinkler wrench across the frame arms. Wrench (Part No. DO NOT overtighten. 14047W/Bw)K Use only the designated is shown) sprinkler wrench, Viking Part Number 14047W/B or 14031, x)KA 112' ratchet is required (not D? NOT apply more than available from Viking). 25 ft. lbs, of torquie. A leak tight seal should be achieved Step 2: Carefully press the by turning the sprinkler Step 1 Carefully slide the wrench upward and turn slightly clockwise 1 to 1-112 turns wrench sideways around to ensure engagement with the beyond finger tight. the deflector and pins, sprinkler wrench flats. Figure 2: Sprinkler Installation and Correct Use of Wrenches 1/2' (15 mm) NPT 2-3/4' 2-1/4" 2-3/16" (70 mm) PIE= (57.2 mm) (561 mm) Maximum Minimum 1 2-3/4' (70 mm) or 3-5/16" (841 mm) Note: Upon sprinkler activation, the deflector descends to approximately 13/16" (20.6 mm) below the sprinkler body. Figure 3: Sprinkler Dimensions and Cover Installation THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_103005 Replaces page 54a-e, dated August 9, 2007. (Added FM Approval.)