Loading...
07201379 Permit File CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 C E R T I F I C A T E OF O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 3/21/08 Parcel Number . . . . . 273-001900 Property Address . . . 6770 PERIMETER DR FR DUBLIN OH 43016 Subdivision Name . . . Legal Description . 6805 PERIMETER ROAD 13.35 AC RAIL VAN GLOBAL LOGISTICS OFFICE BUILDING Property Zoning . . . . PLANNED COMMERCE DISTRICT Owner . . . . . . . . . ZEBRA HOLDINGS LLC Contractor . . . . . . BELISLE CONSTRUCTION INC. 815 254-4504 Application number 07-00201379 000 000 Description of Work COM BUILDING ALTERATION Construction type . . . 5B - UNPROTECTED COMB Occupancy type . . . . BUSINESS Flood Zone . . . . . . Special conditions . . DAVITA, INC Approved . . . . . . . 'g Official VOID UNLESS SIGNED BY LDING OFFICIAL CITY OF DUBLIN Division of Building Standards • 5800 Shier Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 COMMERCIAL INSPECTION SIGN-OFF Project Name: DAVITA, INC. Use Group: B Construction Type: VB Application No: 07-201379 Project Address: 6770 PERIMETER DRIVE General Contractor: f~ r)Stra&fion Building Code: 07 OBC Sewer Tap "Rough Sprinkler Footing 777 Electric Service ykb-"bl N Foundation Steel Framing 171%, fty r1 Footing Steel Grounding Shaft Walls Foundation Insulation Piers Fireplace Waterproofing Curb, Walk & Approach Electrical Underground Above Ceiling Electric TAOV, Plumbing Underground Above Ceiling HVAC / /3/~~ e'rflce ss~ "Sprinkler Underground "Above Ceiling Sprinkler Pre-Slab , A//y 7 ~p /3L Above Ceiling Structural 31 / 3/09' Diamonds Final Electric Structural Steel Final Plumbing Fireproofing Final HVAC Masonry Wall Grout Final Gas Piping (GIs y/r 3 /f f' Z "Fire Alarm Rough "Fire Prevention 3 08 Q,P,e~ AA& Rough Electric Zoning Final Rough Plumbing , 11, o7 Engineering Final Rough HVAC Occupancy Rough Gas Piping aL 'Please call Washington Township Fire Department at 652-3920 to schedule these inspections. DATE INSPECTION COMMENTS APPROVAL INSPECTOR TYPE CODE Re MA ' oy Q evc a/c z rr Gted-ol . Z 14,4 1 4 r0 A4A a~ x~o FftItlAflr 1lvTki¢lbrt SmarZT D 7 v A .2 Sy/.~ mss exavs/ AV- 3` tar. c L-,~-~ s s.-W acs /r.~/i®r- fyr~ h r a /mod G~-o /r ZG d~ roc ~r~~ 7111 ee rl a CMG a %~s cam7 vet Y G yC s/~~ G~ dr~ SERr14-2007 09:15 City of Dublin 6147616566 P.02 CITY OF DUBLIN 680 Shier "s Road Division of Building Standards Dublin, Ohio 43016 COMMERCIAL BUILDING Telephone: 61441046r0 PERMIT APPLICATION Insgecdon Una: 6144144680 ' FaesirNt.: ci4-761~ssc FROJECT INFORMATION s (n'1170Perimeter Drive ProjeclSq Ftg. 5,995 s ft* ted Coat of ConstrueGon 4 Parcel Number PROPERTY OWNER INFORMATION Oww Name (Conbd Person ii owned by a Corporation) Dawn Salisbury Y Nwo Zebra Holdinas~ LLC Adam 5775 Perimeter Drive q Dublin Stale OH Zp_ 43017 T am-------614-799-2800 F E TENANT INFORMATION (K Applicable) Name Michael K. Lynch PwVany Nium Addroas 661 Woodcrest Lane Slam Tr, 7586 6 - 257 - F5.com TECT, ENGINEER, OR OTHER DESIGN PROFESSIONAL INFORMATION ' DesigriftknionaiNarne William R. Davison Ohio RegXertNumber Davison Smi th Certo Ar h; teAbdtiress city Westlake Sbte Zip as 1 a 5 440-835-3957 Fax44n-8IS-~ E scan GENERAL C TRACTOF NgFQRMATION jMust be a City of Dublin Regis MU Co cKor) onlaat Name C 0*" me, I Dublin Re ' 0 ny anus 16 v Addren. r . e• state ~L _ Zp a T Fak- E AFFIDAVIT OF OWNER AUTHORIZATION FOR REPRESENTATION ote: This person will be contacted with all official correspondence. All signatures trust be ORI mi - a Repreeentatrve William R. Davison Relatiatship to Project -Architect arty Name Davison 9nith Arch Position Phi nC; ~,1 Telephone wan-Ft~S-~ca57 i, Michael K. Lynch (please print), the owner and applicant, hereby authorize William R. Davison act as my representative and agent in AN matters pertaining b the processing and approval of this application including moffifing the project, and I agree b be bound by all representations and agreements made by the designated agent ioreture of Property Owner. / le: 09-1 7-2 n m William R. Davison the Miner or the Owners Repreeentstive, have read and understand die contents of ail 3 pages of this application. The in ti contained in this Application, attached exhibits Lm er Womration submitted is oomplate end' aspects and act. to the beat d my knowledge and boW. of Owners R reeentallve: , te. 09-17-2007 C Sullcling Stan r s 151YIsion Use n y bate Rece ved Building Stan a s tion Number t jq commeRcm WIUMG PO N" AP?UCAMN Iy01 e13 ?.VAS..'V1001FO11M61r.OYYN?.rM7 fey ka mi 00b; "A U0• SEP-14-2007 09 15 City of Dublin 6147616566 P.03 CITY OF DUBLIN Division of Building Standards COMMERCIAL BUILDING PERMIT APPLICATION Project Name DaVita, Inc. Permit Number PROJECT INFORMATION NOTE: The following information is to be completed by the Design Professional, registered in the State of Ohio, who was primarily responsible for the preparation of the construction documents. Scope of Project TYPE OF WORK (Check all that apply) A. New Structure B. Addition Fire Wall you No C. Alteration x Article 34 Yes No D. Change of Use Entire Structure Partial E. Change of Occupancy[D Entire Structure Partial Previous Use(s) Use Group(s) ANALYSIS OF NEW STRUCTURE, ADDITION, AND/OR AREA TO BE ALTERED A. Occupancy Description_ Business (vacant) Use Group(s). 'B' Business B. Mixed Use: Yes Non-separated =Separated No x C. Type of construction VB D. Fire resistive construction Fire Test Design Numbers Exterior Walls 0 hr. Fire Walls 0 hr. Floor/Ceiling 0 hr. Columns/Bearing Wall 0 hr. Exit Enclosures 0 hr. Shafts - hr. Corridors 0 hr. Tenant Separation 0 hr. E. Floor Area/Floor Occupant Load/Floor Egress Capacity/Floor Number of Exits Basement 1st 5,995 36 2 24 3rd 4th & above F. Allowable maximum floor area (first floor footprint)9,000 s q. ft. Does the above include street frontage increase? YesB No x Does the above include increase for sprinklers? Yes No x G. Number of stories above grade One (1) Height 27' to ridge BAsement Yes[::] No Mx COMMERCIAL, 9ULDI1413 PERMIT APPLICATION Pogo 2 of 3 P1PASSNAL DGLFORMSICONIMAPPMA2 Faro/ BL I34(" Dole: la" Im ~r'*n - • i_ ' ~hi~:31L~' • • • u iti~'iTi~~1,T~, • IN SEP-14-2007 09:15 City of Dublin 6147616566 P.04 vw A A %_f JL L V "A j L1V Division of Building Standards COMMERCIAL BUILDING PERMIT APPLICATION H. Horizontal exits Yes X No L Limited sprinkles system Yes No J. Full automatic sprinkler system Yes No K. Standpipe system Yes No X L. Smoke control/Removal system Yea No X M. Unlimited area building Yes No X N. Manual fire alarm Yes No X 0. Auto fire alarm Yes 'No X P. Handicap accessible route (exterior & interior) Yes x NoL_J Q. Structural Loads: provide table of design loads wM construction documents N/A EXISTING STRUCTURE ANALYSIS (Complete for all alteration or addNion projects) A. Occupancy Description Vacant Use Group(s) ' B' mousiness B. Mixed Use: Y6s Non-separated =Separated = NoL C. Type of construction VB D. Floor Area/Floor Occupant Load/Floor Egress Capacity/Floor Number of E>fS Basement tst 5.995 36 2nd 2 3rd . 4th & above E. Allowable maximum floor area (first floor footprint) 9,000 s DC1, ft. oes the above include street frontage increase? Yes No X Does the above include increase for sprinklers? Yes No x F. Number of stories above grade One (1) Building Height 27' to ridge Basement Yes= "OF 0. Horizontal exits Yes Ix No H. Limited sprinkler system Yes No X 1. Full automatic sprinkler system Yes No T - J. Standpipe system Yes No 7- K. Smoke control/Removal system Yes No X L. Unlimited area building Yes No X M. Manual fire alarm Yes No X N. Auto fire alarm Yes No X 0. Handicap accessible route (exterior & interior) Yes x No P. Structural Loads: provide table of design loads with construction documents N/A I, William R. Davison the Design Professional, have read and understand the contents of this application. The inform ' n contained in this application, attached exhibits and other information subrnitted, is ete nd in all respells true and correct. to the best of my knowledge and belie . Signature of Design Professional l~J1rI Date: 09-17-2007 COMMMAL "WING PERW APPL!CATION Pm* 3 o1 % RWASSBLDWORMSICOMUMPY02 Form* BLO401 DAIS MIND CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 APPROVAL This is not a Building Permit. It is a record of our review of documents submitted with your application for a Building Permit. November 6, 2007 RE: DAVITA APPLICANT: William R. Davidson, Davidson Smith Certo, Architects, 440.835.3957 ADDRESS: 6770 Perimeter Drive APPLICANT NO. 07-201379(2) The revisions dated 10/23/2007 to the plans dated 9-18-2007 for the captioned project have been reviewed for compliance with the provisions of the Ohio Building Code (2007). The review was based upon the following criteria: Use Group: B-Business Area: 5,995 SF Occupant Load: 60 @ 1:100 Construction Type: VB Notes: 1. Original Shell Permit issued under application 06-200751 2. A ducted return air system has been provided. The architectural documents are sealed by William R. Davis, Ohio registered architect #5261, the HVAC and plumbing documents by Sur it S. Sandhu, Ohio registered engineer #E36971, and the electrical documents by Robert P. Gedeon, Ohio registered engineer #E34690, to comply with the requirements of the OBC Section 106.3.4.1 and have been reviewed, therefore, in accord with OBC Section 104.1. OBC 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the building official or the building official's designated representative. This APPROVAL does not preclude the acquisition of separate permits for plumbing, mechanical, sprinkler or electric. Permits and fees for these items must be obtained from the Building Division prior to the start of any work in these areas. The following items are required for code compliance, but are not necessarily covered in detail in the construction documents. This list is a reminder to the design professional and contractors of issues which are to be satisfactorily dealt with in the field. Item A OBC 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection DAVITA Application No.: 07-201379(2) November 6, 2007 Page 2 of 2 by the building official or the building official's designated representative. Item B OBC 105.7.2 Posting. The certificate of plan approval shall be posted in a conspicuous location outside of the building and in the front part of the premises on which is, or will be the approved building or equipment to which the approved plans relate. The owner and the contractor shall, so far as possible, preserve and keep the certificate posted until the completion of the work to which the approved plans relate. Item C OBC 106.4 Amended construction documents. If substantive changes to the building are contemplated after first document submission, or during construction, those changes must be submitted to the building official for review and approval prior to those changes being executed. The building official may waive this requirement in the instance of an emergency repair, or similar instance. Item D OBC 1103.2.1 Specific requirements. Accessibility is required in buildings and facilities, or portions thereof, to the extent indicated in ADAAG Section 4.1 and this chapter. Item E All electrical will comply with the requirements of Article 27 OBC and the National Electrical Code, NFPA 70, OBC approved edition and is subject to the approval of the electrical field inspector. Item F The existing electrical conductors, if removed, abandoned, or altered, shall be accomplished to the electrical field inspector's approval. Electrical work found not to meet the code's standards shall be corrected to the electrical field inspector's approval The start of construction indicates acceptance of all of the conditions listed above. This review does not preclude the necessity to conform with provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rests with the registered design professional, the tenant and the owner. Approval will be valid only upon receipt by the City of Dublin, Division of Building Standards, of one signed copy of this addendum to the submitted plans. TO REQUEST AN APPEAL HEARING, YOU MUST sent a written request, listing the items to be appealed and the relief sought and a copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 e wed and Signed, Ray M. arp*m,A y er, AIA Commercial Plans Examiner Chief ui ing Official 6:;ntril~ /I - 06-07 Owner or Owner's Representative Date Print Name and Title as Signed NABuilding Standards\Harpham\Reviews 2007\07-201379 cl DaVita.doc • WASHINGTON TOWNSHI RECEIVED ~USTIES FIRE DEPARTMENT NU 5 2001 6200 Eiterman Road, P.O. Box 3248 ~9~F-ERANK~~N: Dublin, Ohio 43016 CITY OF DUBLIN 614-652-3920 • Fax 614-766-2507 DATE: November 2, 2007 TO: Jeffery S. Tyler, Director Division of Building Standards City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 ATTN: Ray M. Harpham, Commercial Plan Reviewer RE: Washington Township's Fire Department Plan Review PROJECT: DAVITA, INC. - TENANT IMPROVEMENTS APPLICATION No: 07-201379(1) & (2) LOCATION 6770 Perimeter Drive RECEIVED: October 16, 2007 (Revision #1) and November 1, 2007 (Revision #2) BUILDING CODE DATA: Use: B, Business Offices for medical treatment. Construction: V B, Combustible/Unprotected Structure. Area: 5,995 SF Total [Tenant Alteration Area] Occupancy: 36 Total Notes: Interior work for the new Tenant build-out of an existing shell building space. The new Tenant Alteration is to be provided with an automatic fire suppression system, as recorded on the Building Code - General Notes listed on Sheet A-1. Mr. Harpham: We have reviewed the Revised Construction Drawings for the referenced project dated 10/24/2007, with Revision #2 submitted to the Division of Building Standards on October 25, 2007, for matters of concern to the Washington Township Fire Department regarding rules relating to fire prevention and the Dublin Fire Code(DFC) based upon the 2000 International Fire Code. We are able to recommend approval of the revised plans and response letter items as submitted. Thank you for the opportunity to review the submission. Please feel free to call with any questions. WASHINGTON TOWNSH P FIRE DEPARTMENT *4VA96 0 Michael A. Boryca, Architect/P xaminer Alan Perkins, CFPS (614) 488-4009 Fire Marshal S:\M m Review\W = Towmft\07-201379 f wo Trustees Gene Bostic - Denise Franz King - Charles Kranstuber Fiscal Officer Joyce E. Robinson Chief Allan Woo Joseph W. Testa, Franklin County Auditor Page 1 of 1 i Street Address Summary i i '/I 1 of 1 Parcel ID Address Index Order Card Parcel Info 273-012164-006770 PERIMETER DR Street Address 1 of 1 Summary - Print View Owner Information Tax Bill Mailing Residential Call 614-462-4663 if incorrect Information Commercial 4+ ZEBRA HOLDINGS LLC Mail Changes Only - Click Improvements 5775 PERIMETER DR Here Sketch/Photo DUBLIN OH 43017 ZEBRA HOLDINGS LLC Map (GIS) Transfer 5775 PERIMETER DR Property Report DUBLIN OH 43017 Tax Information _ - Levy Info Value Information Legal Description Tax Estimator Market Land Value 0 PERIMETER PLACE Tax Distribution Agricultural Value 0 PROFESSIONAL OFFICE Market Impr. Value 0 CONDOMINIUM UNIT 6770 Search By Market Total Value 0 Parcel ID Sales Data Building Data Owner Sale Amount $822,920 Year Built Street Address Date 04/17/2007 Deed Type WD Site Functions # of Parcels 1 Property Search Conveyance # 7774 On-Line Help Exempt # Email Auditor 273 CITY OF DUBLIN-WASH Board of Revision No Home Tax Dist TWp-DUBLIN CSD Homestead No Auditor's Home School Dist 2513 DUBLIN CSD 2.5% Reduction No Tax Estimator by Land Use [000] FUTURE PARCEL Assessments No School/District Neighborhood CDQ Year Contact Us 2006 Annual Taxes $0.00 2006 Total Taxes Paid $0.00 Print << First << First < Previous Next > Last Data updated on 10/04/2007 http://franklin.govenunaxa.com/propertymax/agency/oh-franklin-auditor/franklin tab bas... 10/5/2007 CERTIFICATE OF ZONING PLAN APPROVAL APPLICATION # CITY OF DUBLIN. DATE ISSUED Land Use and tons Ran„ Flonninp 58W Shier-Rings Road Dublin. Ohio 43016-1236 Phone/ Too: 614-410-4600 roc: 614.410-4747 Web Site: www.dubfin.oh.us NAME OF BUSINESS/ FACILITY OF APPLICABLE) -rid 1 ADDRESS OF SUBJECT PROPERTY '7D RnlotRg NAME OF APPLICANT/ AUTHORIZED AGENT PHONE ADDRESS OF APPLICANT/ AUTHORIZED AGENT 31 CaJIM IZIX74S ~W (Y NAME OF PROPERTY OWNER PHONE PLEASE DESCRIBE IN LAYMAN'S TERMS THE EXISTING AND PROPOSED USE(S) OF ALL PARTS OF THE LAND AND/OR BUILDINGS. IF A CHANGE OF USE IS PROPOSED, PLEASE EXPLAIN. (1E, RETAIL SPACE TO MEDICAL OFFICE SPACE, ETC.) VACAMT- 8v r UPluc, w'734 ~zp c -!p 3 cgsCD-ova ~ - ~LL~IJ`LY 'p(/~ L 'a)142 /'G L-rVy 55 PLEASE SUBMIT THE FOLLOWING: ? ONE (1) ORIGINAL SIGNED APPLICATION ? ONE (1) COPY OF A SCALED SITE PLAN DRAWN IN INK indicating all current and proposed land uses, structures, and other site improvements. Additional documentation may be required for various types of projects. Partial or incomplete applications and drawings cannot be processed and will be returned to the applicant by mail. APPLICANT ATURE: DATE: W C&' C W T- FOR OFFICE USE ONLY CASE NUMBER DATE CASE NUMBER DATE CASE NUMBER DATE NOTES: ZONING INSPECTION REQUIRED UPON COMPLETION? YES NO If yes, please call 614-410-4660 to schedule an inspection. A Certificate of Zoning Compliance will be issued after the work is inspected and approved by Land Use and Long Range Planning. APPROVED APPROVED AS NOTED This Certificate of Zoning Plan Approval is issued for, and in reference to the property and use described above, and as approved by the City Administrator or designee, or the City Council, Board of Zoning Appeals, Planning & Zoning Commission, or the Architectural Review Board as appropriate. DISAPPROVED AS NOTED BY: DATE: CERTIFICATE OF ZONING PLAN APPROVAL 3110/2006 CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 APPLICATION FOR GAS PIPING PERMIT Date °~t v 7 Application No. c)-4 - P'o \ -7~5 9 Job Address G 7 7 / l~~ /yt tC- ~L ~b l A , a K) Parcel No. Subdivision Lot No. Owner Name v Telephone Contractor Name Q t-.Ssh Liu cdo Telephone $ ' ~3 0 Z--. Contractor Address Dublin Registration No. ( ) Residential ( ) Commercial ( ) Alter Existing ( ) Addition to Building ( ) Replace/Repair Existing Type of Pipe to be Installed: (Iron CSST ( ) Other it Min. Pipe Size Required: 2-- in. Re_pilator Size. j ~4 BTU Max. Gas Appliances BTU/HR Range Water Heater 2- Dryer Gas Logs Log Lighter Furnace(s) Other: FEE $70.00 3% State of Ohio Surcharge (commercial only) 41, /o Total _ Total $ "7a - /0 JOB DESCRIPTION This permit is granted on the express condition that the s7workshall II respects, conf orm to the ordinances of the City of Dublin and all the laws of the State regulating construction, installatiorati , an ay be revoked at any time upon violation of any provisions of said laws. Signature of licensed contractor or homeowner Division of Building Standards CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Application Number . . . . . 07-00201379 Date 12/21/07 Revision number . . . . . . . 2 Property Address . . . . . . 6770 PERIMETER DR Parcel Number: 273-001900 Alternate Address: PERIMETER WEST OFFC PARK Tenant nbr, name . . . . . . DAVITA, INC. Application type description COM BUILDING ALTERATION Property owner . . . . . . . ZEBRA HOLDINGS LLC Contractor . . . . . . . . . BELISLE CONSTRUCTION INC. Structure Information 000 000 Construction Type . . . 5B - UNPROTECTED COMB Occupancy Type . . . . . . BUSINESS Permit . . . . GAS PIPING PERMIT Additional desc Permit Fee . . . . 70.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/18/08 Qty Unit Charge Per Extension BASE FEE 70.00 Special Notes and Comments SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 SEPARATE SIGN PERMITS REQUIRED. CONTACT LAND USE AND LONG RANGE PLANNING AT 614/410-4600. AT 614/410-4600. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 1. ORIGINAL SHELL PERMIT ISSUED UNDER APPLICATION 06-200751. 2. A DUCTED RETURN AIR SYSTEM HAS BEEN PROVIDED. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE Other Fees . . . . . . . . . SURCHARGE FEE - GAS LINE 2.10 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 07-00201379 Date 12/21/07 Revision number . . . . . . . 2 Fee summary Charged Paid Credited Due Permit Fee Total 70.00 .00 .00 70.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 2.10 .00 .00 2.10 Grand Total 72.10 .00 .00 72.10 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Date 0 2 Application No. 6 Q Q a O 13 2 41 (0 -710 APPLICATION FOR ELECTRICAL PERMIT Job Address Parcel No Subdivision Lot No. Owner Name 'PA j ITk Telephone Contractor Name S'~/~IZ ~G7M~ ale 'Telephone 4 IV- 27 5-- Ed Zb Contractor Address 3 W2 6~11ZAWr -4-\I,---' Dublin Registration No. (501 lu city off 1/3i;2-3 Residential: New Sq. Ft. Alteration/Addition Sq. Ft. Temporary Service $40.00 $40.00 Minimum plus $20.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Low Voltage Systems: Square Feet $40.00 Minimum plus $10.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Commercial: New Sq. Ft. 69 9 5=0 Alteration/Addition Sq. Ft. Temporary Service $60.00 $60.00 Minimum plus $60.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. and up to 50,999 Sq. Ft. (sizes above, See Fee Schedule) Low Voltage Systems: Square Feet $30.00 Minimum (plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.) 3% State of Ohio Surcharge (commercial only) Total $ 330 - 90 JOB DESCRIPTION 614 / LVW 4 T 7t44AiT - Z u! L q ""4uT ' This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of Dublin, all the laws of the State and the National Electric Code regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provi ions of said laws. Signature of licensed contractor or homeowner Division of Building Standards Date: 1/1/2001 CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00201379 Date 11/07/07 Revision number . . . . . . . 2 Property Address . . . . . . 6770 PERIMETER DR Parcel Number: 273-001900 Alternate Address: PERIMETER WEST OFFC PARK Tenant nbr, name . . . . . . DAVITA, INC. Application type description COM BUILDING ALTERATION Property owner . . . . . . . ZEBRA HOLDINGS LLC Contractor . . . . . . . . . BELISLE CONSTRUCTION INC. Structure Information 000 000 Construction Type . . . . . 5B - UNPROTECTED COMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 360.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/05/08 Qty Unit Charge Per Extension BASE FEE 60.00 5.00 60.0000 THOU COM ELECTRIC SERVICE 1K-50K SF 300.00 Special Notes and Comments SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 SEPARATE SIGN PERMITS REQUIRED. CONTACT LAND USE AND LONG RANGE PLANNING AT 614/410-4600. AT 614/410-4600. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 1. ORIGINAL SHELL PERMIT ISSUED UNDER APPLICATION 06-200751. 2. A DUCTED RETURN AIR SYSTEM HAS BEEN PROVIDED. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. e CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . 07-00201379 Date 11/07/07 Revision number . . . . . 2 Other Fees . . . . . . . . . SURCHARGE FEE - ELECTRIC 10.80 Fee summary Charged Paid Credited Due Permit Fee Total 360.00 .00 .00 360.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 10.80 .00 .00 10.80 Grand Total 370.80 .00 .00 370.80 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Application Number . . . . . 07-00201379 Date 11/06/07 Revision number . . . . . . . 2 Property Address . . . . . . 6770 PERIMETER DR Parcel Number: 273-001900 Alternate Address: PERIMETER WEST OFFC PARK Tenant nbr, name . . . . . . DAVITA, INC. Application type description COM BUILDING ALTERATION Property owner . . . . . . . ZEBRA HOLDINGS LLC, Contractor . . . . . . f3efS(C (1oy7S-fm&f o/l - - - - - Structure information 000 000 Construction Type . . . . . 5B - UNPROTECTED COMB Occupancy Type . . . . . . BUSINESS - Permit . . . . . . COMMERCIAL BUILDING PERMIT Additional desc . . 5,995 SQUARE FEET Permit Fee . . . . 1120.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/04/08 Qty Unit Charge Per Extension BASE FEE 320.00 10.00 80.0000 THOU COM BLDG PLAN REVIEW 800.00 Special Notes and Comments SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 SEPARATE SIGN PERMITS REQUIRED. CONTACT LAND USE AND LONG RANGE PLANNING AT 614/410-4600. AT 614/410-4600. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 1. ORIGINAL SHELL PERMIT ISSUED UNDER APPLICATION 06-200751. 2. A DUCTED RETURN AIR SYSTEM HAS BEEN PROVIDED. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . 07-00201379 Date 11/06/07 Revision number . . . . . . . 2 Other Fees . . . . . . COM BLDG INSPECTION ALT 460.00 COM CERTIFICATE OF OCC 120.00 SURCHARGE FEE - BLDG 51.60 Fee summary Charged Paid Credited Due Permit Fee Total 1120.00 .00 .00 1120.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 651.60 .00 .00 651.60 Grand Total 1771.60 .00 .00 1771.60 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 APPLICATION FOR HVAC PERMIT -Z7 Application No. 6 7 Date Job Address n 770 Per-7me` m '1>,-, Parcel No. Lot No. Subdivision Owner Name ba v - Telephone Contractor Name Ar I r T yy`f. Telephone '7 40 JAl I Contractor Address AO O -7 :P' k2 2_1? E4'-,e, 6A Dublin Registration No. 5- 1-13Of g Residential: Sq. Ft. $50.00 Minimum plus $20.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. (Replacement units, minimum fee) i'Commerciah n ` New/Addition Sq. Ft. Alteration New/Addition: $50.00 Minimum plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Alteration: $50.00 Minimum plus $10.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. 3% State of Ohio Surcharge (commercial only) Total $ JOB DESCRIPTION T<h~ ` This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of Dublin and all the laws of the State regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. Signature of licensed contractor or homeowner Division of Building Standards- 1_yT_1 -0 ° CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00201379 Date 11/16/07 Revision number . . . . . . . 2 Property Address . . . . . . 6770 PERIMETER DR Parcel Number: 273-001900 Alternate Address: PERIMETER WEST OFFC PARK Tenant nbr, name . . . . . . DAVITA, INC. Application type description COM BUILDING ALTERATION Property owner . . . . . . . ZEBRA HOLDINGS LLC Contractor . . . . . . . . . BELISLE CONSTRUCTION INC. Structure Information 000 000 Construction Type . . . . . 5B - UNPROTECTED COMB Occupancy Type . . BUSINESS Permit . . . . . . COM HEATING, VENTILATING, A.C. Additional desc . . Permit Fee 100.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/14/08 Qty Unit Charge Per Extension BASE FEE 50.00 5.00 10.0000 THOU COM HVAC ALT 50.00 Special Notes and Comments SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF 'S'OP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 SEPARATE SIGN PERMITS REQUIRED. CONTACT LAND USE AND LONG RANGE PLANNING AT 614/410-4600. AT 614/410-4600. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 1. ORIGINAL SHELL PERMIT ISSUED UNDER APPLICATION 06-200751. 2. A DUCTED RETURN AIR SYSTEM HAS BEEN PROVIDED. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 07-00201379 Date 11/16/07 Revision number . . . . . . . 2 Other Fees . . . . . . . . . SURCHARGE FEE - HVAC 3.00 Fee summary Charged Paid Credited Due Permit Fee Total 100.00 .00 .00 100.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 3.00 .00 .00 3.00 Grand Total 103.00 .00 .00 103.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 462-3865 (Franklin County) Application No. 07- Date v B1Vew ? Remodel ? Residential [Commercial APPLICATION FOR PLUMBING PERMIT The undersigned hereby applies for a permit to do plumbing and an inspection of same at the following location in accord with Chapter 4101:2-51 of the Ohio Administrative Code, and all regulations of the Franklin County Board of Health. Job Address '170 T tom- ~ ct1, Parcel No. Subdivision/Project N(arne Lot No. Owner's Name L/a?V 144 Telephone Contractor's Name Pot K S A L Telephone&~,2 Contractor's Address -3 S-31 nf'X , 0, Dublin Registration Number Does the sewer discharge into an individual sewage disposal system or sanitary sewer? ~•~s How far distant from any dwelling, well or cistern is the sewage tank? A What is the size of the main drain? Jr Of what materials do the vent pipes consist? C ,vc Of what material does the house drain consist? P orC *INDICATE NAME OF CERTIFIED BACKFLOW TESTER This form must be properly filled out and returned to the office of the City of Dublin at least four days prior to the date of the FIRST INSPECTION, accompanied by a fee calculated upon the following basis: WATER TANK REPLACEMENT FEE $35.00 RESIDENTIAL COMMERCIAL Application for permit & first fixture $50.00 Application for permit & first fixture $60.00 e O Number of remaining fixtures X $10.00 = $ Number of remaining fixtures X $12.00 = $ 0 0If" Total Inspection Fee $ Total Inspection Fee Re-inspection fee (based upon disapproved Inspection and collected by the Franklin County Board of Health ONLY) $45.00 Qty. Qty. Qty. Air Admittance Valve Garbage Disposal Showers *Backflow Preventers ,Z. Gas Water Heater Sterilizers Bath Tubs Electric Water Heater Sump Pump Bed Pan Washers Interceptor Trap Primer Bidet Kitchen Sink Urinal Chemical Sinks Laundry Trays Wash Fountain Dental Cuspidors Lavatories S Washing Machine Dilution Sum Mop Sinks Water Closets 5 Dish Washers Outside Faucets Water Lines Drinking Fountain Roof Drains Water St ra Tank Floor Drains Rough-in Openings for Future Other 14Mt5,k. 140 Garage Catch Basin Sewage Ejectors GRAND TOTAL' ^ 119,1 Division of Building Standards CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 07-00201379 Date 11/08/07 Revision number . . . . . . . 2 Property Address . . . . . . 6770 PERIMETER DR Parcel Number: 273-001900 Alternate Address: PERIMETER WEST OFFC PARK Tenant nbr, name . . . . . . DAVITA, INC. Application type description COM BUILDING ALTERATION Property owner . . . . . . . ZEBRA HOLDINGS LLC Contractor . . . . . . . . . BELISLE CONSTRUCTION INC. Structure Information 000 000 Construction Type . . . . . 5B - UNPROTECTED COMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . PLUMBING PERMIT Additional desc . . Permit Fee . . . . 636.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/02/10 Qty Unit Charge Per Extension BASE FEE 60.00 48.00 12.0000 EA COM PLUMBING >1 FIXTURE 576.00 Special Notes and Comments SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 SEPARATE SIGN PERMITS REQUIRED. CONTACT LAND USE AND LONG RANGE PLANNING AT 614/410-4600. AT 614/410-4600. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 1. ORIGINAL SHELL PERMIT ISSUED UNDER APPLICATION 06-200751. 2. A DUCTED RETURN AIR SYSTEM HAS BEEN PROVIDED. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Page 2 Application Number 07-00201379 Date 11/08/07 Revision number . . . . . . . 2 Fee summary Charged Paid Credited Due - Permit Fee Total 636.00 .00 .00 636.00 Plan Check Total .00 .00 .00 .00 Grand Total 636.00 .00 .00 636.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. 10/15/2007 07:47 6144623951 FRANKLIN 00 HEALTH PAGE 01/01 FRANKLIN CO HEALTH PAGE 01/01 l•j8~~ Y3:10 6144623851 Franklin County Board of Health O Two sets of plumbing plans ONLY PLUMBING REVIEW complete with isometrics are TRANSMITTAL required. One set will be returned. Number of Fixtures: Plan Review Fee Schedule 1 ~r DD Amount Due: 1 - 5 Fixtures $ 25.00 6 -20 Fixtures $ 35.00 21 - 40 Fixtures $ 65.00 41 or more Fixtures $100.00 NEW REMODEL Date: OAT.- to 1 2400 1 Job Name: VAVI" II.~G~ Address: 1 1 n ~ECLI (~16 1~ (Z City; 'Pu(3('1 IJ orHi Signature: w~. ITH l Tb ITe ~ u- L)qv Plans Submitted by:,UVw E(Z I1X1~ Address. -2,(020.31 C IlY & zip 150nA vc ~N • 44 1 Phone 'T` - U 4 S Paid By: ~l~r 1 _ d APPROVED Check U DISAPPROVED tQ4 A~ Copy To: inspector. ~:2 0 -7 Date: I -a Franklin County Board of Health ? 280 East Broad Street • Columbus, OH 43215 (614) 462-3160 phone * (614) 462-3851 fax DA' Solt. Sll"f RECEIVED c~T LETTER OF TRANSMITTAL SEP 18 2007 September 17, 2007 g 2 07 BUILDING DIVISION CITY OF DUBLIN Project: DaVita - Dublin, OH ® prints DSCA Project No: 07.078 ? tracings ? diskette Division of Building Standards ? letter City of Dublin 0 application 6800 Shier Rings Road ? shop drawings Dublin, OH 43016 ? specifications ? samples via: Hand Delivered (WRD) ? other Quanti Date Description Action 1 09-17-07 Commercial Building Permit Application B 4 09-18-07 Signed / Sealed Drawings B These are transmitted: A. For approval D. Approved G. Revise & resubmit B. For your use E. No exceptions H. For review & comment C. As requested F. Note exceptions I. For bids due: Remarks: Please contact us at mail@dscarchitects.com or 440-835-3957 to discuss any questions or comments you may have regarding this project. Thank you Signed: William R. Davison cc: Michael Lynch, DaVita, Inc. File 2x031 B i~E~t9. : REL' . WESTl1tKE;:;: «HIQ:::: A!1t46 FAG . ..lAD . . . . . . . . CITY OF DUBLIN Memo Building Standards 5800 Shier-Rings Road Dublin, Ohio 43016-1236 Phone: 614-410-4670 Fax: 614-761-6566 To: Dana McDaniel, Deputy City Manager/Director of Economic Development From: Jeffrey S. Tyler, AIA, CBO/Director of Building Standards RE: Review Synopsis of Davita, Inc. - Kidney Dialysis 6770 Perimeter Drive Application No.: 07-201379 Date: November 6, 2007 This memo is a response to the attached e-mail which was sent to Jane Brautigam, City Manager by Judy Beal, Assistant Clerk of Council, on October 23, 2007. You will note that Ms. Cindy Olsworth was concerned about the status of the Davita building permit, a permit that is in the process of being reviewed and issued. I have also attached the Commercial Permit Review History concerning this permit and all associated, pertinent documents in order to present a complete chronology of events to you. The permit took a total of 49 days to be reviewed, that review included two re-submittals by the applicant. There was never any time in which our in-house reviews exceeded our self-imposed, 25-day deadline, thus there was never any time in which we exceeded the state statutory requirement of 30 days. Also of note, are the various e-mail "conversations" that were held between staff and either the applicant or the owner. Finally, there is an attached chronology from Jan Rozanski explaining the specific events surrounding the Building Standards' stars conversations with the woman who we now know was Ms. Olsworth. If you have any questions or concerns, please contact me. C: Ray Harpham Jan Rozanski Steve Snyder TA0FFICE\WP\D0CS\D0C\Memos from JST 2007\Davita to Dana 07.1106.doc (11%6/2007) Jeff Tyler - INFO D Just in case Page 1 From: Judy Beal To: Brautigam, Jane Date: 10/23/2007 11:19 AM Subject: INFO - Just in case Hi, Jane. In the event this inquiry is also forwarded to Council or your office; we wanted to make you aware of the phone call we received yesterday afternoon and how it has been handled. 1. Cindy Olsworth called to inquire how to contact Council to learn the status on a building permit that has been denied. The permit is for a dialysis center. Her husband must receive dialysis treatments. When they learned their doctor would be relocating to Dublin when his new building was completed, the Olsworths moved 'across the street" from the new building to be near him. The building permit was initially denied. She has been informed that, although ifs been some time, a second submittal has not yet been approved. Is it also being denied? The time involved in this process means that their doctor may be vacating his present location and not relocating anywhere for awhile. If that occurs, she has been advised that she will need to seek treatments for her husband elsewhere for awhile. She called the Building Department about the status and was told she could go online and check the status of the permit. She tried to do that, but could not. She just wanted to know the status on the permit was it a slow approval process, or were there issues that were going to require her to investigate other options for her husband? I told her that actually Council wouldn't know the status on the permit without first contacting the Building Department. And since she had rot really been able to do that - if I could get the name of someone there for her to talk to, would she want to do that first? Then, if she still didn't have satisfactory answers, she could certainly talk to Council. She agreed. I called Building Dept and reached Jan Rozanski, who advised that Steve Snider would be able to tell her what the issues were and a time frame for approval. I called Ms. Olsworth back and provided Steve Snidees # and told her to call us back if she continued to have questions after speaking with him. 2. Jan called our office this AM to update us. Ms. Oisworth caged the Building Dept immediately after speaking with us and actually reached Jan. After he spoke with her, Steve Smith, Jr. also caged him. Since then, he has faxed copies of the City's correspondence to the architect, including the list of issues, to Steve Jr. Ray Harpham has informed him that with the first permit submittal an extensive list of issues were identified. The list was sent to the architect. The architect responded, addressing only 50%. Ray Harpham has been attempting to get the architect to provide the additional information so that he is not forced to deny the permit again. So, its an architect issue ...and Steve Jr. is on it. (Jan says that the has heard "through the grapevine" that Steve Jr.'s wife may work for this doctor... not sure??????) That's it! Tuesday, November 06, 2007 Commercial Permit Review History Review Services Team MY OF DDBWL # 07-201379 s.f - $425,000 initial Submittal 09/18/07 Davita, Inc Kidney Dialysis Initial Permit issued 11/06/07 6770 Perimeter Drive Total Days to initial Permit 49 Rev # Review Type (and Description) Appik annt Window Review (review Round Round Turnaround Intake Dab Dane Days Outcome Pwformance 0 Tenant Fitup (initial submittal) 09/18/07 10/05/07 17 Dl Average 1 Tenant Fitup (resubmittal) 7 10/12/07 10/25/07 13 WD Early 2 Tenant Fitup (replacement plan sheets) 0 10/25/07 11/06/07 12 A3 Early Commercial Permit Plan Review Round Number HTE Rev Round Intake Size (s.f.) Valuation 07-201379 (0) 09/18/07 $425,000 - Office, Medical Individual Review Done Action Day Davita, Inc Kidney Dialysis Ray BLDG 10/01/07 D 13 Alan FIRE 10/05/07 A 17 6770 Perimeter Drive Kristin ENGR 09/18/07 N 0 Tenant Fitup Dave LAND 09/19/07 N 1 ( initial submittal) Dave ZONE 09/21/07 A 3 Team Done Team Outcome Team Performance Team Logo 10/05/07 D1 17 days Average Permit Ready Permit Issued 11/05/07 11/06/07 Review Services Team • Permit Plan Review Round Number HTE Rev Round Intake_ Size (s.f.) Valuation 07-201379 ( 1) 10/12/07 $425,000 Office, Medical Individual Review Done Action Day Davita, Inc Kidney Dialysis Ray BLDG 10/25/07 H 13 Ray FIRE 10/25/07 H 13 6770 Perimeter Drive Kristin ENGR 10/12/07 N 0 Tenant Fitup Dean LAND 10/17/07 N 5 ( resubmittal) Dave ZONE 10/26/07 A 14 Team Done Team Outcome Team Performance Team Logo 10/25/07 WD 13 days Early Permit Ready Permit Issued 11 /05/07 11/06/07 Review Services Team Commercial Permit Plan Review Round Number HTE Rev Round Intake Size (s.f.) Valuation 07-201379 (2) 10/25/07 $425,000 - Office, Medical - Individual Review Done Action Day Davita, Inc Kidney Dialysis Ray BLDG 11/06/07 A 12 6770 Perimeter Drive Alan FIRE 11/05/07 A 11 Kristin ENGR 10/25/07 N 0 Tenant Fitup Dave LAND 10/26/07 N 1 (replacement plan sheets) Dave ZONE 10/26/07 A 1 Team Done Team Outcome Team Performance Team Logo 11/06/07 A3 12 days Early Permit Ready Permit Issued 11/05/07 11/06/07 Review Services Team (1 S/5/2007) Jeff Tyler - Emergency Power DaVita/Dublin #2 Page 1 From: Ray Harpham To: Ann Vogt <ann.vogt@davita.com> CC: Tyler, Jeff; Zombek, Ted Date: 11/2/2007 4:41 PM Subject: Emergency Power DaVita/Dublin #2 Apologies I mis-applied code references in my previous email. Corrections are indicated in Blue below. Ann: We are confirming the 4:00 PM telephone conference with you Monday, November 5, 2007. We will call 800-936-9601, access code 330-220-7431 to begin the conference. We believe that the 2005 NEC (NFPA 70) requires emergency power for the dialysis machines and point to the following as the basis for that position: NEC 517.25 Scope The essential electrical system for these facilities shall comprise a system capable of supplying a limited amount of lighting and power service, which is considered essential for life safety and orderly cessation of procedures during the time normal electrical service in interrupted for any reason. This includes dinia, medical and dental offices, outpatient facilities, . and other health care facilities serving patients. NFPA 99 (2005)14.[Odw Health Care Fadlides]3A.2 Essential Electrical Distribution System. The essential electrical distribution shall conform to a Type 3 system as described in Chapter 4. NFPA 99 (2005)14.10ther Health Care Fadlitties]3A.2. 2 If Critical Care areas are present, the essential electrical distribution shall conform to a Type 1 system as described in Chapter 4. NFPA 99 (2005) 33.138.1 Critical Care Areas.... and similar areas in which patients are intended to be subjected to invasive procedures and connected to line operated, patient-care-related electrical appliances. NFPA 99 (2005) 4.6.2.2.2 Connection to the Essential Electric System [Type 3]. (Wftd we read) The system shall supply power (1) for task illumination that is related to the safety of life and (2) that is necessary for the safe cessation of procedures in progress. and, for what it is worth, the state of Oregon, Dept of Human Services, Public Health Division currently maintains Licensing procedures of outpatient renal dialysis facilities that, in section 333-700-0130, requires, among other things, that all facilities initially licensed or constructed after 3uly 1, 2003, be made to allow connection to an alterative power source and that the alternate power source provide on-going power for lighting and continued provision of dialysis services. It has been represented to us that no other jurisdictions have required emergency power for the your dialysis units. We would appreciate someone with DaVita being a part of the conference that would help us understand how the NEC can be interpreted to establish that the dialysis machines should not be provided with emergency power. It may also be helpful to have someone available that would be able to communicate the nature of the procedure and the risks to which patients are exposed when a power outage occurs. Please call with any questions. Cordially, Ray Ray M. Harpham, AIA Commercial Plans Examiner City of Dublin, Building Standards 614.410.4612 Direct 614.517.4606 Cell 614.718.4346 Fax 614-410-4670 Permit Staff (11/5/2007) Jeff Tyler - Fwd: DaVita Dublin App #07-201379 Page 1 From: Ray Harpham To: Smith, Stephen CC: Tyler, Jeff Date: 10/23/2007 2:14 PM Subject: Fwd: DaViita Dublin App #07-201379 Attachments: DaVita Dublin App #07-201379 Steve: Thank you for the call last night Attached is the email memo for which I was searching madly while we were talking. The memo was to the design architect and applicant for the permit. It was intended to confirm the portion of the conversation regarding the electrical issues that I instigated on Oct 17 after preliminarily reviewing his resubmitted documents. Original Submission Received - 09/18107 Correction Request Issued -10/05/07 Resubmission Received -10/12/07 TC Architect/Applicant - 10/17/07 Applicant was advised that the resubmission was 10-14 days away from review because of the current number of applications pending and that insufficient or incorrect information was provided for the following matters identified in the initial correction request: 1. The 2004 Energy Code was used instead of the 2006 Code required by OBC; 2. Graphics had not been provided for rated assemblies and fire stopping as had been requested; 3. It was important to indicate on the drawings where the wheelchair storage and coats were to be located that were not permitted to be in the vestibule as was shown on the original submission; 4. Proper clearance for the electrical panels had to be provided; and, 5. A description of the Dialysis Procedures needed to be provided. And that if the infor nation/revisions could be provided to our office within 10 days we would be able issue a full approval rather than another correction request. Feel free to call with any questions. Ray Ray M. Harpham, AIA Commercial Plans Examiner City of Dublin, Building Standards 614.410.4612 Direct 614.517.4606 Ceti 614.718.4346 Fax 614-410.4670 Permit Staff October 22, 2007 Comments from: Jan Rozanski, Sr. Building Inspector Shortly before 5:00 p.m. I received a call from Judy Beal (Assistant Clerk of Council) regarding a building permit for Davita, Inc. A woman (do not have her name) called and wanted to know why we had not issued a building permit for Davita, Inc. While I was still speaking with Judy, the woman called my phone, at which time I ended my call with Judy and took the call from the woman. The woman's concern was that we were holding up the permit and that her dad needed treatment (dialysis), with us not issuing a permit, it would create a hardship for both her and her father. I gave her Steven Snyder's (Review Services Coordinator) name and phone number so that he could advise her of the status of the permit application. Shortly after her call, Steve Smith, Jr. (legal counsel) called with the same questions. I gave Mr. Smith the same information. After speaking with Mr. Smith, I went upstairs to see Ray Harpham (Commercial Plans Examiner) to find out for myself where the permit stood. By this time, Ray had also received a call from Mr. Smith concerning Davita, Inc. After speaking with Ray and another call with Mr. Smith, we felt that Mr. Smith had enough information to speak with the woman intelligently. The following day, I was informed that Robyn Harp (Permit Office Assistant) had spoken with this same woman approximately one hour prior to the call I received. Robyn had informed the woman of the status of the permit, plus Robyn gave her the permit number and how to access the website to track the status of the permit herself. I feel that too many people and too much time were spent on this (4 people from our office, plus the Council Assistant and Legal Counsel, and still not including the time you have spent reviewing the issue). We don't even know if this woman is a Dublin resident. T:\OFFICE\WP\DOCS\DOC\Rozanski\Davita, Inc. Comments 07.1025.doc (11/5/2007) Jeff Tyler - DaVita Dublin App #07-201379 Page 1 From: Ray Harpham To: Bill Davidson <mail@dscarchitects.com> CC: Tyler, Jeff; Zombek, Ted Date: 10/18/2007 1:53 PM Subject: DaVita Dublin App #07-201379 Bill: We have typically considered a door in the open position that encroaches upon 3'-0" required Depth of Working space to not comply with the requirements of NEC 110.26(A)(1). Please relocate the panel or the door. Your response to Item 5 induded a reference to NFPA, Annex B, Paragraph 61.4.1. Missing, I believe, is which NFPA Publication contains the referenced annex B. I also note that you described what the procedure is not rather than what it is. Please have the procedure described in detail. In parkular we are interested in the impact of a power outage on 12 very young or aged, frail patients in the middle of a procedure. It will help us in our decision regarding the need for emergency power to the equipment. Please call or reply with any questions. Ray Ray M. Harpham, AIA Commercial Plans Examiner City of Dublin, Building Standards 614.410.4612 Direct 614.517.4606 Cell 614.718.4346 Fax 614-410-4670 Permit Staff October 5, 2007 UNIFIED RESPONSE LETTER (URL) Mr. William R. Davison CITY OF DUBLIN- Davison Smith Certo Architects 26031-B Center Ridge Road Review Services Westlake, OH 44145 MM Shm-Rinp Road Dublin, OH 43016-1236 Re: Dublin Permit Application #07-201379 Fax::: 614-s171188-4346 460o DaVita, Inc. Fax: www.dublin.oh.us Dear Mr. Davison: The City of Dublin's Review Services Team has completed review of materials submitted September 18, 2007, for your request for Addendum to a Commercial Permit. At this time, the overall review status is disapproved and the building permit is denied. The outcome of each review is as follows: Ohio Building Code - disapproval (plan review letter attached) Zoning & Landscape Requirements - approval Dublin Fire Code - favorable (plan review letter attached) Site Engineering Standards - favorable Note the Building Plan Review Letter is not a Building Permit. Please provide a unified resubmittal responsive to the attached review letters consisting of three (3) updated and complete plan sets and the disapproved marked up check prints to our Building Permit Window, 5800 Shier-Rings Road. To facilitate review of your resubmittal, a written description of your responses to the itemized plan review letter comments (and other plan changes you may propose) is requested and recommended. I am available to handle general status and procedural questions. Technical questions pertaining to the plan review letters may be directed to the appropriate plan reviewer. Sincerely, Steve A. Snyder, P.E. Review Services Coordinator SAS/df Attachments CITY OF DUBLIN Division of Building Standards * 5800 Shier Rings Road * Dublin, Ohio 43016 Inspection Requests: (614)410-4680 Telephone: (614)410-4670 SUBCONTRACTOR DISCLOSURE Application Number: 07-201379 Project Address: 6770 PERIMETER DR General Contractor: BELISLE CONSTRUCTION INC. Telephone: (815) 254-4504 All registrations must be current through the issuance of a Certificate of Occupancy, including insurance and all applicable State Certifications. TYPE NAME DUBLIN REG. # (required) EXCAVATION ELECTRIC HVAC A r f. one CV t f PLUMBING C. 41e,7 CONCRETE / LANDSCAPING SANITARY SEWER The General Contractor is required to provide a completed copy of the above information to the Building Official at the time of the Certificate of Occupancy inspection. From: "Bill Davison" <bdavison@dscarchitects.com> To: "Jennifer Brock" <JBrock@dublin.oh.us> CC: "Michael K Lynch" <Michael. K. Lynch@davita.com> Date: 11/6/2007 5:45 PM Subject: Re: Davita Jennifer, This maybe late, because I believe the contractor has picked up the permit The general contractor is: Belisle Construction, Inc. 1914 Donmaur Drive Crest Hill, II. 60403-1905 Jim Pechin, project manager ph. 815-823-8254 fax 815-254-4507 cell 815-342-8342 If you need any additional information, please contact me. Thank you, William R. Davison Davison Smith Certo Architects, Inc. 26031-B Center RidgeRoad Westlake, OH 44145 440.835.3957 phone 440.835.4042 fax bdavison@dscarchitects.com Original Message From: "Jennifer Brock" <JBrock@dublin.oh.us> To: <bdavison@dscarchitects.com> Sent: Tuesday, November 06, 2007 11:37 AM Subject: Davita Bill, I am preparing the paperwork for Davita now that the review has been completed. Has a general contractor been selected? This is required to release the permit. Thank-you, Jennifer Jennifer Brock City of Dublin Building Standards 5800 Shier-Rings Road Phone: 614-410-4670 Fax: 614-761-6566 qqo October 5, 2007 UNIFIED RESPONSE LETTER (URL) Mr. William R. Davison Davison Smith Certo Architects ci c5 OF t,t t,tt~ . 26031-B Center Ridge Road Review Services Westlake, OH 44145 5800 Shier-Rings Road Dublin, OH 43016-1236 Re: Dublin Permit Application #07-201379 Phone: 614-410-4600 DaVita, Inc. Fax: 614-718-4346 www.dublin.oh.us Dear Mr. Davison: The City of Dublin's Review Services Team has completed review of materials submitted September 18, 2007, for your request for Addendum to a Commercial Permit. At this time, the overall review status is disapproved and the building permit is denied. The outcome of each review is as follows: Ohio Building Code - disapproval (plan review letter attached) Zoning & Landscape Requirements - approval Dublin Fire Code - favorable (plan review letter attached) Site Engineering Standards - favorable Note the Building Plan Review Letter is not a Building Permit. Please provide a unified resubmittal responsive to the attached review letters consisting of three (3) updated and complete plan sets and the disapproved marked up check prints to our Building Permit Window, 5800 Shier-Rings Road. To facilitate review of your resubmittal, a written description of your responses to the itemized plan review letter comments (and other plan changes you may propose) is requested and recommended. I am available to handle general status and procedural questions. Technical questions pertaining to the plan review letters may be directed to the appropriate plan reviewer. Sincerely, Steve A. Snyder, P.E. Review Services Coordina or SAS/df Attachments CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 CORRECTION REQUEST #1 This is not a Building Permit. It is a record of our review of documents submitted with your application for a Building Permit. October 1, 2007 RE: DAVITA APPLICANT: William R. Davidson, Davidson Smith Certo, Architects, 440.835.3957 ADDRESS: 6770 Perimeter Drive APPLICANT NO. 07-201379 The plans dated 9-18-2007 for the captioned project have been reviewed for compliance with the provisions of the Ohio Building Code (2007). The review was based upon the following criteria: Use Group: B-Business Area: 5,995 SF Occupant Load: 60 @ 1:100 Construction Type: VB Notes: 1. Original Shell Permit issued under application 06-200751 2. A ducted return air system has been provided. The architectural documents are sealed by William R. Davis, Ohio registered architect #5261, the HVAC and plumbing documents by Sur it S. Sandhu, Ohio registered engineer #E36971, and the electrical documents by Robert P. Gedeon, Ohio registered engineer #E34690, to comply with the requirements of the OBC Section 106.3.4.1 and have been reviewed, therefore, in accord with OBC Section 104.1. OBC 106.3 Examination of documents. The building official shall examine or cause to be examined the accompanying construction documents and shall ascertain by such examinations whether the construction indicated and described is in accordance with the requirements of this code. The construction documents, which have been submitted, do not allow the City of Dublin to issue a permit to begin construction. The following item(s) shall be brought into full compliance with the the requirements of the OBC prior to the issuance of any plan approval. Item 1 106.1.1 Information on construction documents. Construction documents shall be dimensioned and drawn upon suitable material. Electronic media documents are permitted to be submitted when approved by the building official. Construction documents shall be coordinated and of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code. Construction drawings shall include information necessary to determine compliance with the building, mechanical, plumbing and fire protection codes such as: a. 8. Ratings. The fire-resistance ratings of all structural elements as required by this code, data substantiating all required fire-resistance ratings, including details showing how penetrations will be made for electrical, mechanical, plumbing and communication conduits; pipes and systems and the materials and methods for maintaining the required structural integrity, fire-resistance rating and firestopping. i. Please provide, on the drawings, the complete UL #U404 assembly available for DAVITA Application No.: 07-201379 October 1, 2007 Page 2 of 4 use on the Underwriter's Laboratory web site. ii. Reference is made in the Wall Legend, Sheet A-1, to the rated assembly being tight to the metal deck above. The structure is VB Wood Frame and the shell was approved for wood roof sheathing. Please provide site-specific interior wall sections that indicate how the wall will be terminated and how the truss member penetrations of the rated assembly will be protected. iii. Please provide graphic illustrations of through penetrations, required by OBC 712.3. of the rated walls iv. The walls between Rooms 108 & 109 and 115 & 116 are f re-resistance rated one hour. Please provide installation details for EH2 that maintain the required one hour rating. b. 9. System descriptions. Complete description of the mechanical and electrical systems, including: materials, routing, and sizes of all piping; location and type of plumbing fixtures and equipment; plumbing schematics and isometrics; materials, routing and sizes of all ductwork; location and type of heating, ventilation, air conditioning and other mechanical equipment and all lighting and power equipment i. Provide the Reports for the lighting and HVAC systems that indicate compliance with the applicable provisions of the 2006 International Energy Conservation Code or the requirements of the 2004 ASHRAE 90.1 listed in Chapter 35 of the code. Please insure that the mechanical and electrical drawings indicate compliance with Section 3: Requirements Checklist for Lighting and Section 4 Requirements Checklist for Mechanical ii. Please remove all reference to "as required" and "as required by the local authority "from the documents. The authority having jurisdiction will review the documents submitted for compliance with the 2007 Ohio Building Code. In matters involving technical design analysis of work affecting public health or general safety in the following areas: means of egress, structural, mechanical, electrical, plumbing or fire protection, the decision regarding applicability of a code requirement must remain with the professional, registered in the state of Ohio, who has prepared the documents to be reviewed. (1) Specification 2H notes trap primers are to be installed where shown or "as required" by Codes. Trap Primers are not shown on the drawings and required by OPC 1002.4 where the required trap seal is subject to loss by evaporation, a trap seal primer valve shall be installed. Indicate on the drawings which trap seals are subject to loss by evaporation and require, therefore a trap primer. (2) Specification 3.6 notes dampers are to be provided as shown and required. Dampers are not shown on the drawings and are required where supply and return air ducts penetrate a rated assembly. Locate the dampers on the drawings. Item 2 1024.1 [Exit Discharge] General. Exits shall discharge directly to the exterior of the building. The exit discharge shall be at grade or shall provide direct access to grade. The exit discharge shall not reenter a building. a. Room 100 Vestibule does not meet the required exceptions 2.3 and 2.4 to this requirement. The vestibule is not separated from the remainder of the exit discharge by NABuilding Standards\Harpham\Reviews 2007\07-201379 cl DaVita.doc DAVITA Application No.: 07-201379 October 1, 2007 Page 3 of 4 construction providing protection at least the equivalent of approved wire glass in steel frames and the vestibule must be utilized only for means of egress or exit and cannot therfore be utilized for coat and wheelchair storage Item 3 NEC 110.26 A requires 3 %2 feet clear working space in front of Panel MDP at least 30 inches wide. a. Door 121 encroaches on the required front working space of Panel MDP Item 4 OBC 1006.3 requires that the illumination emergency power system shall provide power for a duration of not less than 90 minutes. a. Please indicate on the drawings that the fixtures indicated to have an emergency ballast be capable ofproviding illumination for 90 minutes. Item 5 NEC 517.45 Essential Electrical Systems for Other Health Care Facilities. Requires the essential electrical distribution system to be a battery or generator system. a. The dialysis machines require an alternative source ofpower complying with NEC 517.30 to 517.35. Please describe the system in the documents for review. Item 6 The grounding system for the existing 60 amp panel may not be sufficient to comply with the requirements of NEC 250.50 for the proposed new 600 amp panel. Please provide additional information. Item 7 Review and Approval of Plumbing Drawings and inspection of Plumbing installations are performed by the Franklin County Board of Health Item 8 The Washington Township Fire Marshal has requested an opportunity to provide input to the Dublin building department on issues relating to fire protection. The building official has evaluated the Fire Marshal's comments related to the fire protection provisions of the OBC and incorporates those comments, by reference, into this Phased Plan Approval and Correction Request. a. Please include resolution of the matters of the Fire Marshal's correspondence to Building Standards in your reply to this Correction Request. This review is based upon the information contained within the submitted drawings and related documents. Once corrections are made, submit four (4) new and complete sets of plans to the City of Dublin, Division of Building Standards with any revisions clouded. Please also provide a letter that identifies the action taken in rsponse to any of the Items contained in this Correction Request. TO REQUEST AN APPEAL HEARING, YOU MUST sent a written request, listing the items to be appealed and the relief sought and a copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin 5800 Shier Rings. Road Dublin, Ohio 43016 NABuilding Standards\Harpham\Reviews 2007\07-201379 cl DaVita.doc DAVITA Application No.: 07-201379 October 1, 2007 Page 4 of 4 Re ' wed and Si ed, V I, Ray M. Harpham, Architect Jeffrey S. Tyler Commercial Plans Examiner Chief Building Official Owner or Owner's Representative Date Print Name and Title as Signed NABuilding Standards\Harpham\Reviews 2007\07-201379 c1 DaVita.doc 1 • ' 'USTIES pR,• WASHINGTON TOWNSHIP FIRE DEPARTMENT 6200 Eiterman Road P.O. Box 3248 Dublin, Ohio 43016 614-652-3920 • Fax 614-766-2507 Q OAT DATE: October 3, 2007 200 TO: Jeffery S. Tyler, Director Division of Building Standards City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 ATTN: Ray M. Harpham, Commercial Plan Reviewer RE: Washington Township's Fire Department Plan Review PROJECT: DAVITA, INC. - TENANT R"ROVEMENTS APPLICATION No: 07-201379 LOCATION 6770 Perimeter Drive RECEIVED: September 18, 2007 BUILDING CODE DATA: Use: B, Business Offices for medical treatment. Construction: V B, Combustible/Unprotected Structure. Area: 5,995 SF Total [Tenant Alteration Area] Occupancy: 36 Total Notes: Interior work for the new Tenant build-out of an existing shell building space. The new Tenant Alteration is to be provided with an automatic fire suppression system, as recorde on the Building Code - General Notes listed on Sheet A-1. Mr. Harpham: We have reviewed the Construction Drawings for the referenced project dated 09/18/2007, submitted to the Division of Building Standards on September 18, 2007, for matters of concern to the Washington Township Fire Department regarding rules relating to fire prevention and the Dublin Fire Code(DFC) based upon the 2000 International Fire Code. We are able to recommend a phased approval of the plans and note the following: 1. OBC 106.1.1.1 Fire protection system drawings. Drawings for the fire protection system(s) shall be submitted to indicate conformance with this code and the construction documents and shall be approved prior to the start of system installation. Drawings shall contain all information as required by the referenced installation standards in OBC Ch. 9. a. Sheet Al indicates that a "Sprinkler System" is to be provided The Application for Permit indicates otherwise. Please verify b. When the are made available, submit for approval, prior to the start of system(s) installation, complete information regarding the fire protection systems or the alteration of the system(s) information required by NFPA 13 and 14, Chapter 8, Plans and Calculations for Fire Suppression Systems. If such a system is to be provided 2. DFC 505.1 Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). a. Please verify that approved address numbers will be provided in accordance with the provisions of this code section. Trustees Gene Bostic Denise Franz King • Charles Kranstuber Fiscal Officer Joyce E. Robinson Chief Allan Woo WASHINGTON TOWNSHIP FIRE DEPARTMENT DATE: October 3, 2007 Permit 07-201379 Page 2 of 2 3. OMC 606.4 Controls operation. Upon activation, the smoke detectors shall shut down the air distribution system. Air distribution systems that are part of a smoke control system shall switch to the smoke control mode upon activation of a detector. 606.4.1 Supervision. The duct smoke detectors shall be connected to a fire alarm system. The actuation of a duct smoke detector shall activate a visible and audible supervisory signal at a constantly attended location. Exceptions: 1. The supervisory signal at a constantly attended location is not required where the duct smoke detector activates the building's alarm-indicating appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. Duct smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble. No coordination was provided between the Mechanical and Electrical Sheets indicating compliance with this code section. If a Fire Alarm System is NOT to be provided within this Tenant space, the requirements of Section 606.4.1 Exception 2 shall apply. Please verify these requirements. The information you have provided, does not deny or confirm either of these situations. Please verify. Thank you for the opportunity to review the submission. Please feel free to call with any questions. WASHINGTON TOWNSHIP FIRE DEPARTMENT Michael A- Boryca, Architect/Pla Examiner Alan Perkins, CFPS (614) 488-4009 Fire Marshal SAPIan RmiewMashboon Township\07-201379 pa.wpd