Loading...
08200103 Permit File CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 6/27/08 Parcel Number . . . . . 273-010922 Property Address . . . 6377 EMERALD PKY FR DUBLIN OH 43016 Subdivision Name . . . Legal Description . . . Property Zoning . . . . SUBURBAN OFFICE & INSTIT Owner . . . . . . . . . Contractor . . . . . . DUKE CONSTRUCTION MANAGEMENT 614 932-6000 Application number 08-00200103 000 000 Description of Work COM BUILDING ALTERATION Construction type . . . 2B - PROTECTED/NONCOMB Occupancy type . . . . BUSINESS Flood Zone . . . . . . Special conditions . . SEDGWICK 3RD FLOOR PHASE 3 & 4 Approved . . . . . . . i Vc fic ial VOID UNLESS SIGNED BY ING OFFICIAL JHN-~y-Wdb WV:b1 City of Dublin b14'rb1bbbb H. 02 Building Standards -Review Services Commercial Building Permit Application FEB 0 5 2008 5800 Shier Rinds Road Dublin OH 43016 Phone (614)410-46?6 BUILDING ~ DIVISION CMOFDUOUN. Applica#onNwnberdB•Aco`o3 CIT, nQ1~ UBLI PRojE m0IAii/iJa1WN •'{,'~.~.a:i. a 1~ i i, 7~'+,~ .Vr•J t i~r'i,~;~4V' ,t f'' ~ .,?•~'.t ? New Building ? Building Addition Alteration/Fitup ? Accessory ? Change of Occupancy Project Name pio3oet Sire oZf 3 o u E' p t? e'W r t X Ci"7S S uare Peet r Project Address Estirsawd $ Cost S,38 /3-2 . o s of Construction Tax Parcel OBC Conewetion Type(s) ORC Use Group(s) Number P ~ivsr,t•~st F&4,0- Sv2ivh1 ED ~ 4 Y'J'i.',p M14!Y PROPERTY OWNER Corporate/Company Name(ifapplicable) ovice tZ_--A4 -r C6240V,7.*r/o~ Owner (person's name) Title Address S-G o v a, yE2 e ct-. T 01-/ao City/Statomp ov,Qz--v 0,1/ 4/30 r 2 Telephone Fax Email h ft ~,v TENANT i disable) , l c W11 Company Name 5 p G £/,.i/ C A- C d--,s Contact Name Title Address CitylStatefLip Telephone Fax Email ARCf=CT rr; yMiTr y, ^'y; "J;r,~'«~ F Rri~j Design Professional's Name &4-1 /',v r2fA ~ F6 6 E/ZT Contact Name Ohio Registration Number Address City/Statemp Telephone Fax Email c r n liLNona k (if amicable) :.;'l Design Professional's Name Company Name Ohio Registration Number Address City/StateMp Telephone Fax Email GENERAL CONTRACTOR Company Name Dublin Registration Number Contact Name Title Address City/StareMp Telephone Fax Email PROJECT REPRESENTATM, / CON TACT (ori inbl si!rtasure ngi(ified) : I acknowledge and make this application as, or on behalf of, the owner and further assert that I am the agent / repreaentatlve to be con esning relating 10 this application. Signatar (printriame) uAVE LoduF.~sc~GE/LDate a' S" Company «7V /LE Co~4 rRvCrYaly Phonol~`/- ~/l~/-~2GS $rpail aM~ry. i avDF~btAGE2 ie6 ilLlY.C~+'~ Commercial Building permit Applicativu Page 1 of 3 BLD-201 01/14/08 - JAN-29-2008 09:51 City of D blip b14'(b1bbb8 V.WJ Commercial Building Permit Application Application Number PROJECT INFORMATION ( Completed by Design Professional) Project Address l 111' lFY IlUtll IC, 13 f"6vo2 Y+ 1. ~r : .4. ~;1~4ti Ii1\W'1}~i ;0• fL~Y~ i ~ n New Building ? Accessary Structure ? Addition: Fire Wall 0 Yes ? No ? Change of Use: ? Entire Structure 0 Partial y#Alteration: Article 34 U Yes ? No Q Change of Occupancy: 0 Endre Structure Q Partial Previous Use(s): Zr ,08CUseGroup(s): (6vd/^~€ss Ev~cf rPRiNfrtE v ZfO Occupancy Description: TYPE .27 1 OBC Use Group(s): 6v61 wEsc FGk ~S•~jGl~?~c66~~ Mixed Use, I No I I Yes - if Yes: I I Separated on-Separated OBC Construction Type: Stories Above Grade: 3 Building Height: G/o Basement: ?Yes Fire liesiQtive;Gdi}slructidif t„~I,'` 4lm tvx k; Exterior Walls Hr Fire Walls Hr Floor/Ceiling Hr Columns/Bearing Wall Hr Exit Enclosures Hr Shafts Hr Corridors Hr Tenant Separation Hr tt~on.''', , ~S' AA y~{~~., • :•.t'rVr;4 + u a',,.. Basement 1"Floor o? r 3 v ° 2nd Floor ( 3 01 0 31" Floor a ! 3 0 4' Floor & above Allowable Maximum Floor Area (first floor footprint): Square Feet This value includes: Street frontage increase? ?Yes 0 No Increase for sprinklers? f1Yes fl No Commercial Building Permit Application Page 2 of 3 BLD-201 01114108 JHI14-k:~y-;AlJl1ti LPj 51 CItly of Dublin 614'(bIbbbb F'. W4 Commercial Building Permit Application Application Number PROJECT INFORMATION { Project Address Continued) r uR nWs~ 01 Horizontal Exits Dyes 0 No Smoke controVRemoval system oyes o No Limited Sprinkler System Uyes U No Unlimited Area Building UYes U No Full Automatic Sprinkler System >46 ? No Manual Fire Alarm ?Yes ? No Standpipe System es ? No Auto Faro Alarm gles ? No Occupancy Description: OBC Use Group(s): Mixed Use: g[DNo ? Yes - if Yes: ? Separated §KN•on-Separated OBC Construction Type: Number of Stories Above Grade : Bldg Height: G/v Basement: ?Yes t-io Basement 1"Floor 2" Floor 17 3`d Floor 40'Floor & above Allowable Maximum Floor Area (first floor footprint): Square Peet This value includes: Street frontage increase? ?Yes 0 No Increase for sprinklers? ?Yes ? No j, w •1. Horizontal Exits ?Yes ? No Smoke control/Removal system ?Yes ? No limited Sprinkler System Qyes U No Unlimited Area Building ?Yes 0 No Full Automatic Sprinkler System es 11 No Manual Fire Alarm ?Yes ? No Standpipe System s r No Auto Fire Alarm J40S ? No 1, _ , the Design Professional, have read and understand the contents of this application. The information contained in this application, attached exhibits, and other submitted information is complete and in all respects true and correct, to the best of my knowledge and belief. Signature of Design Professional X Date Building Standards - inprocessing and outprocessing 614-410-4670 Fax 614-761-6566 "jbrock@dublin.oh.us Review Services - plan review activities and tracking 614410-4620 Fax 614-718-4346 oh-us Commercial Building Permit Application Page 3 of 3 BLD-201 01/14108 - CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 APPROVAL This is not a Building Permit. It is a record of our review of documents submitted with your application for a Building Permit. March 18, 2008 RE: Sedgwick CMS Tenant Improvements APPLICANT: Dave Loudenslager, Duke Construction, 614.419.2650 ADDRESS: 6377 Emerald Parkway 3'd Floor APPLICANT NO. 08-200103 and (1) The plans dated 9-17-07, 01/28/08, 1-27-08 and revised sheets 03E200, 201 and 300 for the captioned project have been reviewed for compliance with the provisions of the Ohio Building Code (2007). The review was based upon the following criteria: Use Group: B-Business Area: 21,600 SF Occupant Load: 216 @ 1:100 Construction Type: IIB Notes: 1. The building is fully suppressed. The modifications are being performed under the aegis of Permit 08-200121. 2. The building is provided with a manual fire protective signaling system with audible and visual alarms in all public spaces. The modifications are being performed under the aegis of Permit 08-200088 The architectural documents are sealed by Robert J. Kraemer, Ohio registered architect #12564, the electrical by Alberto De La Tore Lucas, Ohio registered engineer, #E-68678, the mechanical by James S. Linzell, Ohio registered engineer #E-25855 to comply with the requirements of the OBC Section 106.3.4.1 and have been reviewed, therefore, in accord with OBC Section 104.1. OBC 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the building official or the building official's designated representative. The Drawings are APPROVED The following items are required for code compliance, but are not necessarily covered in detail in the construction documents. This list is a reminder to the design professional and contractors of issues, which are to be satisfactorily dealt with in the field: Item A OBC 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and Sedgewick CMS Tenant Improvements Application No.: 08-200103 and (1) March 18, 2008 Page 2 of 3 shall be open for inspection by the building official or the building official's designated representative. Item B OBC 105.7.2 Posting. The certificate of plan approval shall be posted in a conspicuous location outside of the building and in the front part of the premises on which is, or will be the approved building or equipment to which the approved plans relate. The owner and the contractor shall, so far as possible, preserve and keep the certificate posted until the completion of the work to which the approved plans relate Item C OBC 106.4 Amended construction documents. If substantive changes to the building are contemplated after first document submission, or during construction, those changes must be submitted to the building official for review and approval prior to those changes being executed. The building official may waive this requirement in the instance of an emergency repair, or similar instance. Item D OBC 109.1 General. Construction or work for which an approval is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. This includes firestopping and draftstopping (Chapter 7 OBC), mechanical work; piping, ducts and systems (Chapter 3 OMC), structural members and connections (Chapter 16 OBC), and electrical work (Chapter 27 OBC). All systems and elements covered by code are to be inspected and approved before being covered. Item E OBC 1103.1 Where required. Buildings and structures, temporary or permanent, including their associated sites and facilities, shall be accessible to persons with physical disabilities. Item F OBC 1103.2.1 Specific requirements. Accessibility is required in buildings and facilities, or portions thereof, to the extent indicated in ADAAG Section 4.1 and this chapter. Item G All electrical will comply with the requirements of Article 27 OBC and the National Electrical Code, NFPA 70, OBC approved edition and is subject to the approval of the electrical field inspector. Item H The existing electrical conductors, if removed, abandoned, or altered, shall be accomplished to the electrical field inspector's approval. Electrical work found not to meet the code's standards shall be corrected to the electrical field inspector's approval. The start of construction indicates acceptance of all of the conditions listed above. This review does not preclude the necessity to conform with provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rests with the registered design professional, the tenant and the owner. Phased Plan Approval will be valid only upon receipt by the City of Dublin, Division of Building Standards, of one signed copy of this Phased Plan Approval to the submitted plans. TO REQUEST AN APPEAL HEARING, YOU MUST sent a written request, listing the items to be appealed and the relief sought and a copy of this order to: NABuilding Standards\I-larpham\Reviews 2008\08-200103 a Sedgewick.doc Sedgewick CMS Tenant Improvements Application No.: 08-200103 and (1) March 18, 2008 Page 3 of 3 Jeffrey S. Tyler, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 evie ed and Signed, Ray M. arpham, AIA effr y yler, AIA Comme ial Plans Examiner Chie u ding Official Plan Approval will be valid only upon receipt by the City of Dublin, Division of Building Standards, of one signed copy of this Plan Approva f the submitted plans. 7 C) Owner or Owner's Re sentative Date (1711,wa 1! 0 Print Name and Title as Signed NABuilding Standards\Harpham\Reviews 2008\08-200103 a Sedgewick.doc From: Ray Harpham To: Brock, Jennifer Date: 3/3/2008 3:20 PM Subject: Fwd: Re: 08-200103: Sedgwick CMS Jennifer: FYI. Sorry didn't copy you earlier. Ray > > > Ray Harpham 2/28/2008 4:06 PM > > > Dave: Thank you for your request. To accommodate your request for how we must account for the progress of projects in the office, we will withdraw the application until you provide the necessary revisions. When the revisions are ready they will be accepted as Revision #1. We will expedite our review when the revisions are received. Call/reply with any questions. Ray Ray M. Harpham, AIA Commercial Plans Examiner City of Dublin, Building Standards 614.410.4612 Direct 614.517.4606 Cell 614.718.4346 Fax 614-410-4670 Permit Staff "David Loudenslager" <David. LoudenslagerCcbdukerealty.com> 2/28/2008 3:59 PM Ray, Per our phone conversation please suspend the review of the Sedgwick phase 3 & 4 drawings, based upon necessary electrical revisions. Duke will be submitting the requested electrical modifications, along with additional documentation on the lighting conservation certificate, in hopes to receive a full plan approval. Please advise we plan on correcting these issues as soon as possible and this hold will be temporary based on how soon Duke/Denier can compile and submit these updates. Thank You, Dave Loudenslager Duke Construction 614-419-2650 i Page 1 of 1 Jennifer Brock - RE: Sedgwick 3rd Floor From: "David Loudenslager" <David.Loudenslager@dukerealty.com> To: "Jennifer Brock" <JBrock@dublin.oh.us> Date: 3/19/2008 2:21 PM Subject: RE: Sedgwick 3rd Floor Jennifer, Great! I will be there tomorrow to pick up permit. Yes we have divided the space into two phases; as phase 4 is operational while phase three is being completed. We will be applying for a TCO on phase three, move the employees and commence work on phase 4. Ultimately we understand we will not be able to achieve full occupancy on the third floor until phase 3 and 4 are both complete. Thanks, Dave Loudenslager -----Original Message----- From: Jennifer Brock [mailto:JBrock@dublin.oh.us] Sent: Wednesday, March 19, 2008 10:50 AM To: David Loudenslager Cc: Tina Kauffman Subject: Sedgwick 3rd Floor Dave, The permit for Sedgwick (application #08-200103) is ready for pick up. The fee due is $2,760.40. Also, are there two phases on the drawings? For some reason I have a note that it is Phase 3 & 4. Thank-you, Jennifer Jennifer Brock City of Dublin Building Standards 5800 Shier-Rings Road Phone: 614-410-4670 Fax: 614-761-6566 --A r ~ .:v\T ---I 1 /7n/7n114 CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200103 Date 3/19/08 Revision number . . . . . . . 1 Property Address . . . . . . 6377 EMERALD PKY Parcel Number: 273-010922 Alternate Address: Tenant nbr, name . . . . . . SEDGEWICK 3RD FL Application type description COM BUILDING ALTERATION Property owner . . . . . . . Contractor . . . . . . . . . DUKE CONSTRUCTION MANAGEMENT Structure Information 000 000 Construction Type . . . . . 2B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . COMMERCIAL BUILDING PERMIT Additional desc . . 21,600 SQUARE FEET Permit Fee . . . . 1840.00 Plan Check Fee .00 Issue Date . . . . .~q .0% Valuation . . . . 0 Expiration Date . . 9/15/08 Qty Unit Charge Per Extension BASE FEE 160.00 21.00 80.0000 THOU COM BLDG PLAN REVIEW 1680.00 Special Notes and Comments 1. THE BUILDING IS FULLY SUPPRESSED. THE MODIFICATIONS ARE BEING PERFORMED UNDER THE AEGIS OF PERMIT 08-200121. 2. THE BUILDING IS PROVIDED WITH A MANUAL FIRE PROTECTIVE SIGNALING SYSTEM WITH AUDIBLE AND VISUAL ALARMS IN ALL PUBLIC SPACES. THE MODIFICATIONS ARE BEING PERFORMED UNDER THE AEGIS OF PERMIT 08-200088. IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL ey S. Tyler, AIA Other Fees . . . . . . . . . COM BLDG INSPECTION ALT 720.00 COM CERTIFICATE OF OCC 120.00 SURCHARGE FEE - BLDG 80.40 Fee summary Charged Paid Credited Due This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 08-00200103 Date 3/19/08 Revision number . . . . . . . 1 Permit Fee Total 1840.00 .00 .00 1840.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 920.40 .00 .00 920.40 Grand Total 2760.40 .00 .00 2760.40 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 APPLICATION FOR HVAC PERMIT q Date Application No. 10 U - a oo\ Job Address 6y 3 11 I'm c3/L A ~ C7 ?,4 0k~~~ 3 /~fio~C . Parcel No. Subdivision Lot No. Owner Name r ld 0 9! wd c A CMS Telephone Contractor Name ~ ao/ey A-44 Telephone t'#10- 4 7F° Q 4yet Contractor Address .04010 Z e- ft'le,@ 'd( Cd j 61,40 W323 Dublin Registration No. O • ~ Lr Residential: Sq. Ft. $60.00 Minimum plus $30.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. $60.00 REPLACEMENT UNITS GAS ELECTRIC. (Minimum fee only) Commercial: New/Addition Sq. Ft. Alteration &60 12A 444 New/Addition: $70.00 Minimum plus $30.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Alteration: $70.00 Minimum plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.y~t7. 010 3% State of Ohio Surcharge (commercial only) she Total $ .SD 740 JOB DESCRIPTION „ d,le GAAG l;rXi37- n/ 4 .4t dea fz a S j~p 4 eca *i.*" a46414f This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of Dublin and all the laws of the State regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. Signature of licensed contractor or homeowner Division of Building Standards s CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200103 Date 4/11/08 Revision number . . . . . . . 1 Property Address . . . . . . 6377 EMERALD PKY Parcel Number: 273-010922 Alternate Address: Tenant nbr, name . . . . . . SEDGWICK 3RD FL PH 3 & 4 Application type description COM BUILDING ALTERATION Property owner . . . . . . . Contractor . . . . . . . . . DUKE CONSTRUCTION MANAGEMENT Structure Information 000 000 Construction Type . . . . . 2B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . COM HEATING, VENTILATING, A.C. Additional desc . . Permit Fee . . . . 490.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/08/08 Qty Unit Charge Per Extension BASE FEE 70.00 21.00 20.0000 THOU COM HVAC ALT 420.00 Special Notes and Comments 1. THE BUILDING IS FULLY SUPPRESSED. THE MODIFICATIONS ARE BEING PERFORMED UNDER THE AEGIS OF PERMIT 08-200121. 2. THE BUILDING IS PROVIDED WITH A MANUAL FIRE PROTECTIVE SIGNALING SYSTEM WITH AUDIBLE AND VISUAL ALARMS IN ALL PUBLIC SPACES. THE MODIFICATIONS ARE BEING PERFORMED UNDER THE AEGIS OF PERMIT 08-200088. IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA Other Fees . . . . . . . . . SURCHARGE FEE - HVAC 14.70 Fee summary Charged Paid Credited Due This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. aw CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 08-00200103 Date 4/11/08 Revision number . . . . . . . 1 Permit Fee Total 490.00 .00 .00 490.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 14.70 .00 .00 14.70 Grand Total 504.70 .00 .00 504.70 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Date Application No. ©C'~ • Ao©` APPLICATION FOR ELECTRICAL PERMIT Job Address f43 9'1 ~ .I PKw Parcel No. T 00 Subdivision Lot No. Owner Name S EUy it -Jt Lk C4AS Telephone Contractor Name ~6-fw oRIG L,L C- Telephone L H3 4 6 Contractor Address 2003 & Bc ?e N C 1u M61 s W D7-2-8 Dublin Registration No. Residential: New Sq. Ft. Alteration/Addition Sq. Ft. Temporary Service $40.00 $40.00 Minimum plus $20.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Low Voltage Systems: Square Feet $40.00 Minimum plus $10.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Commercial: New Sq. Ft. Alteration/Addition Sq. Ft. Temporary Service $60.00 $60.00 Minimum plus $60.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. and up to 50,999 Sq. Ft. (sizes above, See Fee Schedule) Low Voltage Systems: Square Feet 50.x_ $30.00 Minimum (plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.) i x 30 21, SvJ 3% State of Ohio Surcharge (commercial only) 4 21 ~ Total $ JOB DESCRIPTION 44TAct- 1~;., Jv~~.~.:e ea~~?r tug ~I'~NES d 1~+w~~i^~rS This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of Dublin, all the laws of the State and the National Electric Code regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. Signature of licensed contractor or homeowner r-)T~ , Division of Building Standards Date: 1/1/2001 CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200103 Date 4/03/08 Revision number . . . . . . . 1 Property Address . . . . . . 6377 EMERALD PKY Parcel Number: 273-010922 Alternate Address: Tenant nbr, name . . . . . . SEDGWICK 3RD FL PH 3 & 4 Application type description COM BUILDING ALTERATION Property owner . . . . . . . Contractor . . . . . . . . . DUKE CONSTRUCTION MANAGEMENT Structure Information 000 000 Construction Type . . . . . 2B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . LOW VOLTAGE ELECTRIC PERMIT Additional desc . . Permit Fee . . . . 450.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 9/30/08 Qty Unit Charge Per Extension BASE FEE 30.00 21.00 20.0000 THOU COM ELECTRIC LOW VOLTAGE 420.00 Special Notes and Comments 1. THE BUILDING IS FULLY SUPPRESSED. THE MODIFICATIONS ARE BEING PERFORMED UNDER THE AEGIS OF PERMIT 08-200121. 2. THE BUILDING IS PROVIDED WITH A MANUAL FIRE PROTECTIVE SIGNALING SYSTEM WITH AUDIBLE AND VISUAL ALARMS IN ALL PUBLIC SPACES. THE MODIFICATIONS ARE BEING PERFORMED UNDER THE AEGIS OF PERMIT 08-200088. IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA Other Fees . . . . . . . . . SURCHARGE FEE - ELECTRIC 53.10 Fee summary Charged Paid Credited Due This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. • CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 08-00200103 Date 4/03/08 Revision number . . . . . . . 1 Permit Fee Total 450.00 .00 .00 450.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 53.10 39.60 .00 13.50 Grand Total 503.10 39.60 .00 463.50 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 462-3865 (Franklin County) Application No. V_ ©0 k0 Date ? New t'16model ? Residential ? Commercial APPLICATION FOR PLUMBING PERMIT The undersigned hereby applies for a permit to do plumbing and an inspection of same at the following location in accord with Chapter 4101:2-51 of the Ohio Administrative Code, and all regulations of the Franklin County Board of Health. Job Address Z 3 7 (-,o Parcel No. Subdivision/Project Name 60 'e-k -4-t s, Lot No. Owner's Name Telephone Contractor's Name S/3-JA! - Telephone Q Contractor's Address A 01r r? a~~' `j'</t)'2_D_ublin Registration Number_ ~ • S, l Does the sewer discharge into an individual sewage disposal system or sanitary sewer? How far distant from any dwelling, well or cistern is the sewage tank? ,"V* f What is the size of the main drain? Of what materials do the vent pipes consist? 6is 7" -z,''"/ Of what material does the house drain consist? e4s~ Z/T"' *INDICATE NAME OF CERTIFIED BACKFLOW TESTER This form must be properly filled out and returned to the office of the City of Dublin at least four days prior to the date of the FIRST INSPECTION, accompanied by a fee calculated upon the following basis: WATER TANK REPLACEMENT FEE $35.00 RESIDENTIAL COMMERCIAL Application for permit & first fixture $50.00 Application for permit & first fixture $60.00 Number of remaining fixtures X $10.00 = $ Number of remaining fixtures X $12.00 = $ Total Inspection Fee $ Total Inspection Fee Re-inspection fee (based upon disapproved Inspection and collected by the Franklin County Board of Health ONLY) $45.00 Qri• Qty. Qty. Air Admittance Valve Garbage Disposal Showers *Backflow Preventers Gas Water Heater Sterilizers Bath Tubs Electric Water Heater Sump Pump Bed Pan Washers Interceptor Trap Primer Bidet Kitchen Sink 3 Urinal Chemical Sinks Laundry Trays Wash Fountain Dental Cuspidors Lavatories Washing Machine Dilution Sum Mop Sinks Water Closets Dish Washers Outside Faucets Water Lines Drinking Fountain Roof Drains Water Storage Tank Floor Drains Rough-in Openings for Future Other 4,,q Garage Catch Basin Sewage Ejectors GRAND TOTAL Division of Building Standards 2 4A k Il ID CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200103 Date 4/01/08 Revision number . . . . . . . 1 Property Address . . . . . . 6377 EMERALD PKY Parcel Number: 273-010922 Alternate Address: Tenant nbr, name . . . . . . SEDGWICK 3RD FL PH 3 & 4 Application type description COM BUILDING ALTERATION Property owner . . . . . . . Contractor . . . . . . . . . DUKE CONSTRUCTION MANAGEMENT Structure Information 000 000 Construction Type . . . . . 2B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . PLUMBING PERMIT Additional desc . . Permit Fee . . . . 108.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/25/10 Qty Unit Charge Per Extension BASE FEE 60.00 4.00 12.0000 EA COM PLUMBING >1 FIXTURE 48.00 Special Notes and Comments 1. THE BUILDING IS FULLY SUPPRESSED. THE MODIFICATIONS ARE BEING PERFORMED UNDER THE AEGIS OF PERMIT 08-200121. 2. THE BUILDING IS PROVIDED WITH A MANUAL FIRE PROTECTIVE SIGNALING SYSTEM WITH AUDIBLE AND VISUAL ALARMS IN ALL PUBLIC SPACES. THE MODIFICATIONS ARE BEING PERFORMED UNDER THE AEGIS OF PERMIT 08-200088. IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA Fee summary Charged Paid Credited Due Permit Fee Total 108.00 .00 .00 108.00 Plan Check Total .00 .00 .00 .00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 08-00200103 Date 4/01/08 Revision number . . . . . . . 1 Grand Total 108.00 .00 .00 108.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. 03/26/2888 88:13 6144623851 FRANKLIH CO HEALTH PAGE 01 00 Franklin County Board of Health o PLUMBING REVIEW TRANSMITTAL Number of Fixtures: Plan Review Fee Schedule AVV Amount Due: 1 - 5 Fixtures $ 25.00 6 - 20 Fixtures $ 35.00 21 -40 Fixtures $ 65.00 TWO SETS OF PLUMBING PLAN5 41 or more Fixtures $100.00 COMPLETE WITH ISOMETRIC5 ARE REQUIRED (do not submit full sets) NEW REMODEL Date: z' -Or Job Name: S't"D w C. _s Address. 71 ~7 ri,. £(LA-L o City. ~ THIS APPROVED SET OF PLANS Signature -_MUSTZ&ON-THEJOB SITE. ANY ALTERATIONS TO TIM DESIGNED SYSTEM MUST BE Plans Submitf.,d 0y R€V~ -FED-- . Address. G S St 92__ 13 r,'a- v •b 457 CPhone # ,S`i~ •-~/6 - City 8 Zip Paid By: APPROVED !gs DISAPPR V Check ED Copy To: Inspector,, 'yG Date: 3 •Erenklfb County Board of Health ? 280 East Broad Street Columbus, OH 43215 (614) 462-3160aphone (614) 462-3851 fax w CITY OF DUBLIN Division of Building Standards - 6800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Date March 26, 2008 Application No. 08-200103 APPLICATION FOR ELECTRICAL PERAUT Job Address 6377 Emerald Parkway Parcel No Subdivision %<.,ecl4 e.UJ ~ 31A CA Lot No. Owner Name Duke Realty Telephone Contractor Name Telephone 614338-4664 Denier Electric Co., Inc. Contractor Address Dublin Registration No. 08-237 4000 Gantz Rd., Ste. Gv r iclty, 04431413 Residential: a onlAddition S4,. ~ti Ft- New Sq. Ft. ~11t Temporary Service $40.00 t.n $40.00 Minimum plus $20.00 for each additional 6.00 Sq. or fi746 i tl`eig"LOver 1000 Sq. Ft Low Voltage Systems: Square Feet F- $40.00 Minimum plus $10.00 for each additional 500 Sq. Ft or fracfi6n thereof over 1000 Sq. Ft Commercial: New Sq. Ft. Alteration/Additi6~ -Sq. Ft 21,600 Temporary Service $60.00 $60.00 Minimum plus $60.00 fox' each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft 1,320.00 and up to 50,999 Sq. Ft (sizes above, See Fee Schedule) Low Voltage Systems: Square;Feet $30.00 Minimum (plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft) 3% State of Ohio Surcharge (commercial only) 39.60 Total S 1,35 JOB DESCRIPTION Tenant Remodel This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances 4 the City of Dublin, all the laws of the State and the National Electric Code reg lating construction, install , repair and alteration, and may be revoked at any time upon violation of any provisio of said la Signature of licensed contractor or homeowner Division of Building Standards Date: 1/1/2001 CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200103 Date 3/27/08 Revision number . . . . . . . 1 Property Address . . . . . . 6377 EMERALD PKY Parcel Number: 273-010922 Alternate Address: Tenant nbr, name . . . . . . SEDGEWICK 3RD FL PH 3 & 4 Application type description COM BUILDING ALTERATION Property owner . . . . . . . Contractor . . . . . . . . . DUKE CONSTRUCTION MANAGEMENT Structure Information 000 000 Construction Type . . . . . 2B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 1320.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 9/23/08 Qty Unit Charge Per Extension BASE FEE 60.00 21.00 60.0000 THOU COM ELECTRIC SERVICE 1K-50K SF 1260.00 Special Notes and Comments 1. THE BUILDING IS FULLY SUPPRESSED. THE MODIFICATIONS ARE BEING PERFORMED UNDER THE AEGIS OF PERMIT 08-200121. 2. THE BUILDING IS PROVIDED WITH A MANUAL FIRE PROTECTIVE SIGNALING SYSTEM WITH AUDIBLE AND VISUAL ALARMS IN ALL PUBLIC SPACES. THE MODIFICATIONS ARE BEING PERFORMED UNDER THE AEGIS OF PERMIT 08-200088. IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA Other Fees . . . . . . . . . SURCHARGE FEE - ELECTRIC 39.60 Fee summary Charged Paid Credited Due This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 08-00200103 Date 3/27/08 Revision number . . . . . . . 1 Permit Fee Total 1320.00 .00 .00 1320.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 39.60 .00 .00 39.60 Grand Total 1359.60 .00 .00 1359.60 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. i • • TIES WASHINGTON TOWNSHIP LpUN OF FIRE DEPARTMENT eC/tj~a 9 2 6200 Eiterman Road, P.O. Box 3248 9RF' ^1K` Dublin, Ohio 43016 ~B < 9 614-652-3920 • Fax 614-766-2507 20 016 4F ©UB DATE: February 26, 2008 j~~ TO: Jeffery S. Tyler, Director Division of Building Standards City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 ATTN: Ray M. Harpham, Commercial Plans Examiner RE: Washington Township's Fire Department Plan Review PROJECT: SEDGWICK CMS - TENANT MROVEMENTS APPLICATION No: 08-200103 LOCATION 6377 Emerald Parkway RECEIVED: February 8, 2008 BUILDING CODE DATA: Use: B, Office space. Construction: H B, Noncombustible - Un-Protected [Existing] Area: 21,300 SF [Area of Improvements] Occupancy: 213 Total Notes: Existing building with interior alterations. improvements include new wall partitions with doors and finishes, mechanical, electrical lighting and power requirements. The building currently has an automatic fire suppression system located throughout and fire alarm/detection system, of which will require changes pursuant to the Improvement plans. Mr. Harpham: We have reviewed the construction documents for the referenced Interior Improvements, with as submitted to the Division of Building Standards February 5, 2007, for matters of concern to the Washington Township Fire Department regarding rules relating to the 2007 Ohio Building Code (OBC) and the fire prevention and the Dublin Fire Code(DFC) based upon the 2000 International Fire Code. We are able to recommend approval of the plans submitted with the following conditions: 1. OBC 106.1.1.1 Fin protection system drawings. Drawings for the fire protection system(s) shall be submitted to indicate conformance with this code and the construction documents and shall be approved prior to the start of system installation. Drawings shall contain all information as required by the referenced installation standards in OBC Ch 9. a. When they are made available, submit for approval, prior to the start of system(s) installation, complete information regarding the fire protection systems or the alteration of the system(s) information required by the 2007 NFPA 13, Chapter 22, Plans and Calculations for Fire Suppression Systems and the specifications, wiring diagrams, battery calculation, and floor plans required by NFPA 72 (2007)§A4.5 for Fire Alarm/Detection Systems. b. Separate permits are required for the alterations to the existing Automatic Fire Suppression System, and the Fire Alarm & Fire Detection system. Trustees Gene Bostic • Denise Franz King • Charles Kranstuber Fiscal Officer Joyce E. Robinson Chief Allan Woo i WASHINGTO TOWNSHIP FIRE DEPARTMENT r DATE: February 26, 2008 Permit 08-200103 Page 2 of 2 i 2. OBC 1006.4 Performance of system. Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candlel (0.6 lux) at the end of the emergency lighting time duration. A maximum-to-minimum illumination uniformity ratio of 40 to I shall not be exceeded. OBC 1011.1 Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Acces to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediatel visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet 30 480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. a. Additional exit signs and emergency egress lighting may be required by the Field Inspector and/or Fire Marshal based upon actual'field conditions, including but not limited to conditions created by the placement and configuration of moveable office partitions and furnishings. Thank you for the opportunity to review the submission. Please feel free to call with any questions. WASHINGTON TOWNSHIP FIRE DEPARTMENT MIX/ Michael A Boryca, Architect Cs Examiner Alan Perkins, CFPS (614) 488-4009 Fire Marshal • • STIES WASHINGTON TOWNSHIP GOV OF FIRE DEPARTMENT 6200 Eiterman Road, P.O. Box 3248 ^;Dublin, Ohio 43016 614-652-3920 • Fax 614-766-2507 #419 < 00 Date: /01 dk c 03008 8 To: Jeff Tyler, Director ZZ City of Dublin Division of Building Standards 5800 Shier Rings Road Dublin, Ohio 43016 Re: Washington Township's Fire Department Plan Review Permit 08-0?00/03 Project: E/~cfr~'a rP~rsio Location: 6-Y-17 emergld PY Received: S- /yl aychi "Oe Review Comments: A r he /eyrie e/PC~i'iccs d A ~n « asf~i' To fir r ~Pn r Q rs Fiir Cod o•,g~ v?Oo llU6/ii> Fiie Code.. r~~vrro~ Reviewed By: 6&tiv of. Oft~ Aiie Trustees Gene Bostic • Denise Franz King • Charles Kranstuber Fiscal Officer Joyce E. Robinson Chief Allan Woo M;~R-03-2008 MON 02:41 PM Denier Electric FAX 140, 92222611 P. 01/03 CORRECTION REQUEST #1 This is not a Building Permit. It is a record of our review of documents submitted with your application for a Building Permit. February 28, 2008 RE: Sedgewick CMS Tenant improvements APPLICANT: Dave Loudenslager, Duke Construction, 614.419.2650 ADDRESS: 6377 Emerald Parkway 3" Floor APPLICANT NO. .Sl~*?A819S" G!, . z00i03 The plans dated 9-17-07,01/28/08, and 1-27-08 :For the captioned project have been reviewed for compliance with the provisions of the Ohio Building Code (2007). The review was based upon the following criteria: Use Group: R-Business Area: 21,600 SF Occupant Load: 216 @ 1:100 Construction Type:. 1IB Notes: 1. The building is fully suppressed. The modifications are being performed under the aegis of Permit 08-200121. 2. The building is provided with a manual fire protective signaling system with audible and visual alarms in all public spaces. The modifications are being performed under the aegis of Permit 08-200088 The architectural documents are sealed by Robert J. Kraemer, Ohio registered architect #12564, the electrical by Alberto De La Tore Lucas, Ohio registered engineer, #E-68678, the mechanical by James S. Linzell, Ohio registered engineer #E-25855 to comply with the requirements of the OBC Section 106.3.4.1 and have been reviewed., therefore, in accord with OBC Section 1.04.1. ODC 106.3 Examination of documents. The building official shall examine or cause to be examined the accompanying construction documents and shall ascertain by such examinations whether the construction indicated and described is in accordance with the requirements of this code. The construction documents, which have been submitted, do not allow the City of Dublin to issue a permit to begin construction. The following item(s) shall be brought into full compliance with the the requirements of the OBC prior to the issuance of any plan approval. Item 1 106.1.1 Information on construction documents. Construction documents shall be dimensioned and drawn upon suitable material. Electronic media documents are permined to be submitted when approved by the building official. Construction documents shall be coordinated. and of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code. Construction drawings shall include information necessary to determine compliance with the building, mechanical, plumbing and fire protection codes such as: a. OBC 1301.1.1 [Energy Efficiency] Criteria. Buildings shall be designed and constructed in accordance with the applicable provisions of the 2006 International Energy Conservation Code or the requirements of the 2004 ASHRAE 90.1 listed in MAR-03-2008 MON 02:41 PM Denier Electric FAX NO, 92222611 P. 02/03 Sedgewick CMS Tenant Improvements Application No.: 08-200103 February 28, 2008 Page 2 of 3 Chapter 35 of this code i. The following issues with the Lighting Compliance Certificate need to be resolved before approval of the plans can be issued: (1) The floor area for the application was indicated to be 21,900 SF. The floor area utilized in the Lighting Application worksheet utilized 24,334 SF. Please coordinate the areas and indicate on the drawings the extent of the areas to included in the calculation. (2) The building area method fur the Allowed Lighting Power Calculation permits only 1.0 watts/sf to be ulili ed in the calculation for Office. The Jfrorksheet utilized 1.1 vvattr/sffor its Allowed Lighting Calculations. Please either utilize 1.0 watts/rf for your Allowed Lighting Power Calculation or utilize the space by space nwhod.for calculating the allowed power for lighting. (3) The reviewer counts 299 Linear Fluorescent type 1 ceiling fixtures. The worksheet utilized the quantity 295, Sheet A-4 indicates 308 fixtures. Please coordinate the drawings and the worksheet. (4) No account was taken in the power calculations for the modular, furniture task lighting. Gfrithout regard for (1), (2) and (3) above, the calculations for the power a11o1-t1atrce showed compliance of 1 watt of a 26,767 watt allowance and would require therefore, that no task lighting be provided for the modular furnfshinz, Drawings A-3 and A-6 indicate hi'o task lightingfixtures to be provided at each modular station in the open office areas. (5) Provide automatic shutoff control for the proposed lighting and occupancy sensing corm of for the conference rooms as required by ASHRAE 9.4.1. and provide information on the modular fin-niture task light switching as required by ASHRAE 9.4.1.4. (6) Please confirm that the feeder and branch circuit conductors have been designed for a maximum voltage drop of 2°.o for the feeders and 3%for the branch circuit Item 2 Please also resolve the following issues identified by the reviewer: a. The branch circuit -wiring methods have not been identified b. Panel schedules not identified per 2008 NEC 408.4 C. Disconnecting means for multi-wire branch circuits to comply with. 2008 NEC 210.4B d. Fluorescent luminaries are to have disconnecting means per 2008 NEC 410.130G e. Circuiting information for the luminaries is not indicated on the plans f. Panel RP3E has a connected load (190.55 A) that exceed the rating gfthe panel (150A) g. Panel RP3A has a connected load (149.83 A) that exceeds the rating of the panel ('125 A) h. Panel RP3B has a connected load (184.86 A) that exceeds the rating of the panel (125 A) i. Provide plan igfo for what appears to be the new 1200 A switchboard CADocumems and Sening \Albcno Lucus\ ocni Settings\Temporary Internet Pilcs~OLK1D10 8-2 0 1 03 c 1 Sedgewick.doc i .•MAR-03-2008 MON 02;42 PM Denier Electric FAX NO. 92222611 P. 03/03 Sedgewick CMS Tenant Improvements Application No.: 08-200103 February 28, 2008 Page 3 of 3 ,j. Provide fault current calculations for panel RP3F. Item 3 The Washington Township fire Marshal has requested an opportunity to provide input to the Dublin building department on issues relating to fire protection. The building official has evaluated the Fire Marshal's comments related to the fire protection provisions of the OBC and incorporates those comments, by reference, into this Phased Plan Approval and Correction Request. a. Please include resolution of the matters of the Fire Marshal's correspondence to Building Standards in your reply to this Correction Request. This review is based upon the information contained within the submitted drawings and related documents. Once corrections are made, submit four (4) new and complete sets of plans to the City of Dublin, Division of Building Standards with any revisions clouded. Please also provide a letter that identifies the action talcen in rsponse to any of the Items contained in this Correction Request. TO REQUEST AN APPEAL HEARING, YOU MUST sent a written request, listing the items to be appealed and the relief sought and a copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio X13016 Reviewed and Signed, Ray M. Flarpham, AJA Jeffrey S. Tyler, AIA Commercial Plants Exaniner Chief Building Official Owner or Owner's Representative Date Print Name and Title as Signed CADocununts and Settings\Albeno Lucas\Local Settings\Temporury intcrna riles\01,K1 D\08-20103 cl SedgmicLdoc