Loading...
08200316 Permit File CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 5/09/08 Parcel Number . . . . . 273-002483 Property Address . . . 655 METRO PL S FR DUBLIN OH 43017 Subdivision Name . . . Legal Description . . . 655 S METRO PLACE RD AMD SUB METROCENTER 14.968 ACS Property Zoning . . . . OFFICE LABORATORY RESEARC Owner . . . . . . . . . METROCENTER OFFICE INVESTMENT Contractor . . . . . . INTEGRATED CONSTRUCTION GROUP 614 523-1460 Application number 08-00200316 000 000 Description of Work COM BUILDING ALTERATION Construction type . . . 1B - PROTECTED/NONCOMB Occupancy type . . . . BUSINESS Flood Zone . . . . . . Special conditions . . MCGOWAN - SUITE 580 Approved . . . . . . . ~Oo~' d Of icial VOID UNLESS SIGNED BY BUI ING OFFICIAL CITY OF DUBLIN Division of Building Standards • 5800 Shier Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 COMMERCIAL INSPECTION SIGN-OFF Project Name: McGowan Use Group: B Construction Type: 1 B Application No: 08-200316 Project Address: 655 Metro PI. S. General Contractor: ]Building Code: 07 OBC Sewer Tap **Rough Sprinkler Footing Electric Service Foundation Steel Framing Footing Steel Grounding Shaft Walls Foundation Insulation Piers Fireplace 1 Waterproofing Curb, Walk & Approach Electrical Underground Above Ceiling Electric Plumbing Underground Above Ceiling HVAC **Sprinkler Underground **Above Ceiling Sprinkler Pre-Slab Above Ceiling Structural Diamonds Final Electric ?f~Cp~ A Structural Steel Final Plumbing Fireproofing Final HVAC Masonry Wall Grout Final Gas Piping **Fire Alarm Rough **Fire Prevention ~8- Rough Electric 01~ l Zoning Final / Rough Plumbing Engineering Final Rough HVAC Life Safety Rough Gas Piping Occupancy' "Please call Washington Township Fire Department at 652-3920 to schedule these inspections. DATE INSPECTION COMMENTS APPROVAL INSPECTOR TYPE /f CODE b Yo~ 5- p ' STXo Gvi YTi?~ 5 .~~J c L Building Standards - Review Services Commercial Building Permit Application 5800 Shier Rings Road Dublin OH 43016 Phone(614)410-4670 CITY OF DUBLIN. Application Number Received Date Stamp PROJECT INFORMATION ? New Building ? Building Addition `0* Alteration/Fitup ? Accessory ? Change of Occupancy Q Project Name ~ Project Size / ~~V 'Z4- C./ Square Feet / Project Address / C j Estimated $ C0456 ry (P ~J 11 ~i 4TJ~ of Construction/v'' - Tax Parcel OBC Construction Type(s) OBC Use Group(s) .jam Number ,Q PROPERTY OWNER Corporate/Company Name (if applicable) Owner (person's name) Title P, Ot Address d~ City/State/Zip TelephoneG, 5. Fax`,Y.33S. ZO Email TENANT (if applicable) Company Name Contact Name Title Address City/State/Zip Telephone Fax Email ARCHITECT Design Professional's Name S HA J E Contact Name 77 it 6.4cm Ohio Registration Number ~d Address City/State/Zip Telephone 7q -Z-1000 Fax Z'-loat Email CIVIL ENGINEER (if applicable) Design Professional's Name Company Name Ohio Registration Number Address City/State/Zip Telephone Fax Email GENERAL CONTRACTOR Company Name Dublin Registration Number Aw4dAmo Contact Name w Title Address ~(0 "C *40 City/State/Zip WGl.~ Telephone „l O Fax,% Y Email PROJECT REPRESENTATIVE / CONTACT (original signature required) I acknowledge and make this application as, or on behalf of, the owner and further assert that I am the agent / representative to be contacted concerning m tters re ating to this application. A Signature X (print name) -ygWN l Fox Date 40- I Company L &-v Email.c.r~ Commercial B ' ding Permit Application Page 1 of 3 BLD-201 01/14/08 Commercial Building Permit Application Application Number PROJECT INFORMATION ( Completed by Design Professional) Project Address PROJECT SCOPE & DESCRIPTION /N7, C~v,L /D1'1r*vr /wpea~AW TYPE OF WORK 7 New Building 17. Accessory Structure ? Addition: Fire Wall D Yes No ? Change of Use: Entire Structure F1 Partial t~Alteration: Article 34 Yes No L; Change of Occupancy: L Entire Structure ? Partial Previous Use(s): d` OBC Use Group(s): NEW CONSTRUCTION ANALYSIS (complete for Additions and New Buildings/Structures) Occupancy Description: r OBC Use Group(s): %1j` 12 ,%AgSS Mixed Use: No Yes - if Yes: I Separated I Non-Separated OBC Construction Type: If) Stories Above Grade: 9 Building Height: 17,01' Basement: es No Fire Resistive Construction Rating Fire Test Design Numbers Exterior Walls 2 Hr Fire Walls 2 Hr Floor/Ceiling Z Hr Columns/Bearing Wall Z Hr Exit Enclosures Z Hr Shafts 2 Hr Corridors 0 Hr Tenant Separation U Hr Floor Information Floor Area (s.f.) Occupant Load/Floor Egress Capacity/Floor Number of Exits Basement l't Floor 2nd Floor 3"t Floor 4'h Q w4rwk above Allowable Maximum Floor Area (first floor footprint): Square Feet This value includes: Street frontage increase? -]Yes VNo Increase for sprinklers? es o Commercial Building Permit Application Page 2 of 3 BLD-201 01/14/08 Commercial Building Permit Application Application Number PROJECT INFORMATION ( Project Address Continued) Fire Related Items Horizontal Exits es L_ No Smoke control/Removal system V/yes LJ No Limited Sprinkler System -]Yes INo Unlimited Area Building LYes No Full Automatic Sprinkler System AeS L No Manual Fire Alarm LYes V"N' o Standpipe System es ! No Auto Fire Alarm es No EXISTING STRUCTURE ANALYSIS (complete for Additions and Alteration/Fitups) Occupancy Description: OBC Use Group(s):j' Mixed Use: No Yes - if Yes: Separated L Non-Separated OBC Construction Type: Number of Stories Above Grade : / Bldg Height: Basement: V"Yes I No Floor Information Floor Area (s.f.) Occupant Load/Floor Egress Capacity/Floor Number of Exits Basement /O KOO / d /,~j ; 3 1 s` Floor goo ZQ 5' 2?d Floor Qp 3l. 3`d Floor Zp, $CO 7-06 3 Z 3 4`h Floor & above q00 O Allowable Maximum Floor Area (first floor footprint): Square Feet This value includes: Street frontage increase? Yes 'VeNo Increase for sprinklers? -1 Yes -Fr'No Fire Related Items Horizontal Exits es F No Smoke control/Removal system es 7 No Limited Sprinkler System -]Yes Ao Unlimited Area Building LYes Vlo Full Automatic Sprinkler System /f es L- No Manual Fire Alarm LYes ~No Standpipe System es I-- No Auto Fire Alarm es No I, lip.-KwM Z 6Ae-n1ry , the Design Professional, have read and understand the contents of this application. The information contained in this application, attached exhibits, and other submitted information is complete and in all respects true and c rrect, to Zt y knowledge and belief. QQ ~~~~qq Signature of Design Professional X Date J l~? Contact the City of Dublin - Commercial Building Permits Building Standards - inprocessing and outprocessing 614-410-4670 Fax 614-761-6566 jbrock@dublin.oh.us Review Services - plan review activities and tracking 614-410-4620 Fax 614-718-4346 ssnyder@dublin.oh.us Commercial Building Permit Application Page 3 of 3 BLD-201 01/14/08 CITY OF DUBLIN Building Standards • 5800 Shier Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 WALK-THROUGH ELIGIBILITY EVALUATION FORM Project Name: L 4-sawd4tl , ~j„eT~ 5$Q Project Address:_ &6 morix) ?Lft,` 4_-tn1r1~ Applicant: S10kt4Ly;6A 04-~tAca4 / . _ _ - Phone: '79Z-eoi~ Author of Drawings (in attendance):~4w- f:yme 6y Phone: 74t -loo( General Contractor (required): t riT~L.,a,I) C.oNS~ Contractor Registration Number: Project Square Footage: Circle the appropriate category/categories in each box and put the corresponding point value in the equation at the bottom of the page. A B C D Square Footage Use Group s) Type of Construction Plan Originator 0 to 1000 ..................1.0 Al ...........................3.0 IA.................. 3.0 Ohio Architect, 1001 to 2000 ............(9 A2 ...........................3.0 IB.......................... ~ Ohio Engineer, 2001 to 3000 .............2.0 A3...........................1.8 Certified Designer or a 3001 to 4000 .............2.5 A4...........................1.6 IIA........................... 2.5 combination of 4001 to 5000 .............3.0 A5...........................1.0 I1B........................... 1.0 above...................... B .............................:1.0 Projects over 3, 000 sq. ft. E.... 1.8 IIIA..........................2.5 Non-professional........ 3.0 are not considered without F1 & F2 ....................2.5 1116.......................... 1.3 CBO permission. H N/P Author of the drawings *Rated corridor if 30 or 1 1,2,3 ......................3.0 IV........................... .1.2 must be a certified more occupants. M ............................1.8 professional if the project R ..............................1.5 VA............. 2.5 requires technical analysis S1 ...........................1.4 VB............. 2.5 of safety or sanitation. S2.. 1.2 U ............................1.0 E F G H Nature of Work Permits Required Number of Floors Number of Drawings (Add all permits required) (Involved in the review) (Excluding cover sheet) Alteration ..................1.0 Building.................... 1............................. 1-4. Demolition & Zoning Compliance-.... 1.0 2 .............................2.0 5-8...... 2.0 Build Out HVAC minor/existing... 1.0 9-13........... 3.0 New Building HVAC new system(s)..2.0 Permission required from 14-20 ......................4.5 (<120 sq. ft.) .............1.2 Electrical (minor)........ (13 CBO for any more floors Addition Electrical (new equip)..2.0 involved. (<1,000 sq. fl ............1.0 Change of Permit Occupancy. - ~ .............3.0 Point Total.......... Additions > 1,000 sq. ft. and new buildings > 120 sq. ft. are ineligible. + d + / 2 + Z•O + O + l C7 =~L A B C D E F G H TOTAL • The sum of the above calculation may not exceed 14 for Walk-Through consideration. • The approved Record of Action or any required Zoning hearing is required at this review. • The Plans Examiners will table any examination that will take more than 25 minutes. Fax this completed form, Building Permit Application and Zoning Compliance form to Building Standards 614-761-6566. T:\OFFICE\WP\DOCS\DOC\Excel\2006 walkthrouah CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200316 Date 4/09/08 Property Address . . . . . . 655 METRO PL S Parcel Number: 273-002483 Alternate Address: METRO CENTER Tenant nbr, name . . . . . . 580 MCGOWAN #580 Application type description COM BUILDING ALTERATION Application desc Sq Ft 1908' Property owner . . . . . . . CB RICHARD ELLIS Contractor . . . . . . . . . INTEGRATED CONSTRUCTION GROUP Structure Information 000 000 Construction Type . . . . . 1B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . COMMERCIAL BUILDING PERMIT Additional desc . . Permit Fee . . . 40.0 Plan Check Fee .00 Issue Date . . . . -o-or Valuation . . . . 0 Expiration Date . . 10/06/08 Qty Unit Charge Per Extension BASE FEE 160.00 1.00 80.0000 THOU COM BLDG PLAN REVIEW 80.00 Special Notes and Comments IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL f ey S. Tyler, AIA Other Fees . . . . . . . . . COM BLDG INSPECTION ALT 120.00 COM CERTIFICATE OF OCC 120.00 SURCHARGE FEE - BLDG 14.40 Fee summary Charged Paid Credited Due Permit Fee Total 240.00 .00 .00 240.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . . 08-00200316 Date 4/09/08 Plan Check Total .00 .00 .00 .00 Other Fee Total 254.40 .00 .00 254.40 Grand Total 494.40 .00 .00 494.40 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 Supplement to Walk Through Plan Approval Application Date: 4/7/2008 Application Number: 08 -200316 Property Address: 655 METRO PL S Project Description: MCGOWAN #580 THIS IS NOT A BUILDING PERMIT. IT IS A SUPPLEMENT TO OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT This SUPPLEMENT TO THE PLAN APPROVAL is issued by the City of Dublin, Division of Building Standards. Listed below are items which may not appear in the construction documents, but which are not considered to constitute a hazard serious enough to warrant withholding Plan Approval. The fo/lo wing items are conditions of the issuance of the Plan Approval,, when applicable. Item 1. OBC. 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the the building official or the building official's designated representative. Item 2. OBC 105.7.2 Posting. The certificate of plan approval shall be posted in a conspicuous location outside of the building and in the front part of the premises on which is, or will be the approved building or equipment to which the approved plans relate. The owner and the contractor shall, so far as possible, preserve and keep the certificate posted until the completion of the work to which the approved plans relate. Item 3. OBC. 106.4 Amended construction documents. If substantive changes to the building are contemplated after first document submission, or during construction, those changes must be submitted to the building official for review and approval prior to those changes being executed. The Building official may waive this requirement in the instance of an emergency repair or similar instance. Item 4. OBC 109.1 General. Construction or work for which an approval is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. This includes firestopping and draftstopping /Chapter 7 OBC/, mechanical work, piping, ducts and systems fChapter 3 OMC), structural members and connections /Chapter 16, OBC), and electrical work fChapter 27 OBC/. Existing electrical conductors, if removed, abandoned, or altered, shall be accomplished to the electrical field inspectors approval. Electrical work found not to meet the code's standards shall be corrected to the electrical field inspector's approval All systems and elements covered by code are to be inspected and approved before being covered. Page 1 of 2 Item 6. OBC 1 103.1 Where required. Building and structures, temporary or permanent, including their associated sites and facilities, shall be accessible to persons with physical disabilities. OBC 1 103.2.1 Specific requirements. Accessibility is required in building and facilities, or portions thereof, to the extent indicated in ADAAG Section 4.1 and this chapter. The start of construction indicates acceptance of all the conditions listed above. This review does not preclude the necessity to conform to provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rest with the registered design professional, the tenant and the owner. Plan Approval will be valid only upon receipt by the City of Dublin, Building Standards, of one signed copy of the addendum to the submitted plans. TO REQUEST AN APPEAL HEARING, YOU MUST send a written request, listing the items to be appealed and the relief sought and one copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016-1236 Re i wed and Signed, Ray M. H pham, AIA r yler, AIA Commercial Plans Examiner Chief Iding Official City of Dublin City of ublin 2, -1- OX Signature - Archite , ngineer or Contractor Date p(1/10VI-1 ce vv2S PVW Print Name and Title as Signed Page 2 of 2 CITY OF DUBLIN • Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 462-3865 (Franklin County) y~ Application No. 0181 * Aao 1 ko Date ? New j~Remodel ? Residential ,Commercial APPLICATION FOR PLUMBING PERMIT The undersigned hereby applies for a permit to do plumbing and an inspection of same at the following location in accord with Chapter 4101://2-51 of the Ohio Administrative Code, and all regulations of the Franklin County Board of Health. Job Address (S 5- 11 `-C 'N 0 10 / l4 cR sa °1 tt,\ 1-80 Parcel No. Subdivision/Project Name Lot No. Owner's Name ct < ~o h Telephone Contractor's Name (f 1 S L~ 1Z t14 k w i Telephone *;17 O/C? Contractor's Address 6 70? 9-v A,-vAl s C'+ Dublin Registration Number Does the sewer discharge into an individual sewage disposal system o anitary sewer? How far distant from any dwelling, well or cistern is the sewage tank? What is the size of the main drain? Y Of what materials do the vent pipes consist? C 45 t I ~ Of what material does the house drain consist? C`( ,N:E ("A- 1=11 "INDICATE NAME OF CERTIFIED BACKFLOW TESTER This form must be properly filled out and returned to the office of the City of Dublin at least four days prior to the date of the FIRST INSPECTION, accompanied by a fee calculated upon the following basis: WATER TANK REPLACEMENT FEE $35.00 RESIDENTIAL COMMERCIAL Application for permit & first fixture $50.00 Application for permit & first fixture $60.00 ~ Number of remaining fixtures X $10.00 = $ Number of remaining fixtures X $12.00 = $ 12 , a1 Total Inspection Fee $ Total Inspection Fee ~ Re-inspection fee (based upon disapproved Inspection and collected by the Franklin County Board of Health ONLY) $45.00 Qty. Qty. Qty. Air Admittance Valve Garbage Disposal Showers "Backflow Preventers Gas Water Heater Sterilizers Bath Tubs Electric Water Heater Sump Pump Bed Pan Washers Interceptor Trap Primer Bidet Kitchen Sink Urinal Chemical Sinks Laundry Trays Wash Fountain Dental Cuspidors Lavatories Washing Machine Dilution Sum Mop Sinks Water Closets Dish Washers Outside Faucets Water Lines Drinking Fountain Roof Drains Water Storage Tank Floor Drains Rough-in Openings for Future Other - ! 5, 1 Garage Catch Basin Sewage Ejectors GRAND TOTAL Z Division of Building Standards 15 CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200316 Date 4/28/08 Property Address . . . . . . 655 METRO PL S Parcel Number: 273-002483 Alternate Address: METRO CENTER Tenant nbr, name . . . . . . 580 MCGOWAN #580 Application type description COM BUILDING ALTERATION Application desc Sq Ft 1908' Property owner . . . . . . . METROCENTER OFFICE INVESTMENT Contractor . . . . . . . . . INTEGRATED CONSTRUCTION GROUP Structure Information 000 000 Construction Type . . . . . 1B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . PLUMBING PERMIT Additional desc . . Permit Fee . . . . 72.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/21/11 Qty Unit Charge Per Extension BASE FEE 60.00 1.00 12.0000 EA COM PLUMBING >1 FIXTURE 12.00 Special Notes and Comments IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA Fee summary Charged Paid Credited Due Permit Fee Total 72.00 .00 .00 72.00 Plan Check Total .00 .00 .00 .00 Grand Total 72.00 .00 .00 72.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Date ~400 Application No. © 500 2O0 5~4, APPLICATION FOR ELECTRICAL PERMIT Job Address (r 5 S/~~/ e Parcel No. Subdivision Lot No. Owner Name Telephone Contractor Name/Ait:% Telephone Contractor Address Dublin Registration No. Residential: New Sq. Ft. Alteration/Addition Sq. Ft. Temporary Service $40.00 $40.00 Minimum plus $20.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Low Voltage Systems: Square Feet $40.00 Minimum plus $10.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Commercial: New Sq. Ft. Alteration/Addition Sq. Ft. Temporary Service $60.00 $60.00 Minimum plus $60.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. ~D and up to 50,999 Sq. Ft. (sizes above, See Fee Schedule) Low Voltage Systems: Square Feet $30.00 Minimum (plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.) 3% State of Ohio Surcharge (commercial only) 3,4-O Total $ y~ JOB DESCRIPTION This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of Dublin, all the laws of the State and the National Electric Code regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. Signature of licensed contractor or homeowner t Division of Building Standards Date: 1/1/2001 CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200316 Date 5/02/08 Property Address . . . . . . 655 METRO PL S Parcel Number: 273-002483 Alternate Address: METRO CENTER Tenant nbr, name . . . . . . 580 MCGOWAN #580 Application type description COM BUILDING ALTERATION Application desc Sq Ft 1908' Property owner . . . . . . . METROCENTER OFFICE INVESTMENT Contractor . . . . . . . . . INTEGRATED CONSTRUCTION GROUP Structure Information 000 000 Construction Type . . . . . 1B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 120.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/29/08 Qty Unit Charge Per Extension BASE FEE 60.00 1.00 60.0000 THOU COM ELECTRIC SERVICE 1K-50K SF 60.00 Special Notes and Comments IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA Fee summary Charged Paid Credited Due Permit Fee Total 120.00 .00 .00 120.00 Plan Check Total .00 .00 .00 .00 Grand Total 120.00 .00 .00 120.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. 04/28/08 12:14 FAX 6144623851 COUNTY BOARD-OF HEALTH Z001 _ TO:4623851 P.1 APR-25-2008 08:17A FROM:CLASSIC PLUMBINCINC 6148773110 Franklin County Board of Health ° PLUMBING REVIEW TRANSMITTAL Number of Fixtures: Plan Review Fee Schedule Amount Due: 1 - 5 Fixtures $ 25.00 6 - 20 Fixtures $ 35.00 21 - 40 Fixtures $ 65.00 41 or more Fixtures $100.00 D NEW REMODEL Date: Job Name'G Address:. PLANS MUST City, BE ON THIS JOB SITE. Signature: AN TIONS TO THE D VED SYSTEM MUST' BE REVISED PRI 1 INSPECTION. Plans Submitted by: Address: Phone City & Zip APPROVED Paid By: Check D DiSAPPRO ED l ~ Copy To: Inspector: Date: Franklin County Board of Health • 280 East Broad Street • Columbus, OH 43215 • (614) 462-3160 phone • (614) 462-3851 fax CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Date -5 S~8 Application No. APPLICATION FOR ELECTRICAL PERMIT Job Address b S 5 ~~rCe- S` Parcel No Subdivision b Lot No. Owner Name ~ ICS tGk c~ a~ S Telephone Contractor Name Telephone Contractor Address Dublin Registration No. deq Residential: New Sq. Ft. 12 Alteration/Addition Sq. Ft. Temporary Service $40.00 $40.00 Minimum plus $20.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Low Voltage Systems: Square Feet $40.00 Minimum plus $10.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Commercial: New Sq. Ft. Alteration/Addition Sq. Ft. Temporary Service $60.00 $60.00 Minimum plus $60.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. and up to 50,999 Sq. Ft. (sizes above, See Fee Schedule) Low Voltage Systems: Square Feet Zu $30.00 Minimum (plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.) 3% State of Ohio Surcharge (commercial only) N Total $ JOB DESCRIPTION This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of Dublin, all the laws of the State and the National Electric Code regulating constructi n, installation, repair and alteration, and may be revoked at any time upon violation ofy p vi ions of s ' laws. /i Signature of licensed contractor or homeowner (/L Division of Building Standards Date: 1/1/2001 CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200316 Date 5/05/08 Property Address . . . . . . 655 METRO PL S Parcel Number: 273-002483 Alternate Address: METRO CENTER Tenant nbr, name . . . . . . 580 MCGOWAN #580 Application type description COM BUILDING ALTERATION Application desc Sq Ft 1908' Property owner . . . . . . . METROCENTER OFFICE INVESTMENT Contractor . . . . . . . . . INTEGRATED CONSTRUCTION GROUP Structure Information 000 000 Construction Type . . . . . 1B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . LOW VOLTAGE ELECTRIC PERMIT Additional desc . . Permit Fee . . . . 50.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/01/08 Qty Unit Charge Per Extension BASE FEE 30.00 1.00 20.0000 THOU COM ELECTRIC LOW VOLTAGE 20.00 Special Notes and Comments IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA Other Fees . . . . . . . . . COM BLDG INSPECTION ALT 120.00 COM CERTIFICATE OF OCC 120.00 SURCHARGE FEE - ELECTRIC 5.10 SURCHARGE FEE - BLDG 14.40 Fee summary Charged Paid Credited Due This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Page 2 Application Number . . . 08-00200316 Date 5/05/08 Permit Fee Total 50.00 .00 .00 50.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 259.50 258.00 .00 1.50 Grand Total 309.50 258.00 .00 51.50 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards * 5800 Shier Rings Road * Dublin, Ohio 43016 Inspection Requests: (614)410-4680 Telephone: (614)410-4670 SUBCONTRACTOR DISCLOSURE Application Number: 08-200316 Project Address: 655 METRO PL S General Contractor: INTEGRATED CONSTRUCTION GROUP Telephone: (614) 523-1460 All registrations must be current through the issuance of a Certificate of Occupancy, including insurance and all applicable State Certifications. TYPE NAME DUBLIN REG. # (required) EXCAVATION ELECTRIC Ac j Qc- ELp,- HVAC PLUMBING Ct-A66LC- PLO/ IS(46 t60 CONCRETE LANDSCAPING SANITARY SEWER 40 The General Contractor is required to provide a completed copy of the above information to the Building Official at the time of the Certificate of Occupancy inspection. CERTIFICATE OF ZONING PLAN APPROVAL APPLICATION # C l~ DATE ISSUED fj~'Zcj:~_ Land Use and Long Range Planning 5800 Shier-Rings Road Dublin. Ohio 43016-1236 Phone/ Too: 614-410-4600 Fax: 614-410-4747 Web Site: www.dublin.oh.us NAME OF BUSINESS/ FACILITY (IF APPLICABLE) /1izC70t? ADDRESS OF SUBJECT PROPERTY eP65'Aff0rJ1;&fi" NAME OF-APPLICANT/ AU O IZED AGENT PHONE ki Z- [Ot7~ ADDRESS OF APPLI T/ AUTHORIZED AGENT a- 0 3 -o NAME O OPERTY OWNE PHONE &VY #01r PLEASE DESCRIBE IN LAYMAN TERMS THE EXISTING AND PROPOSED USE(S) OF ALL PARTS OF THE LAND AND/OR BUILDINGS. IF A CHANGE OF USE IS PROPOSED, PLEASE EXPLAIN. (IE, RETAIL SPACE TO MEDICAL OFFICE SPACE, ETC.) PLEASE SUBMIT THE FOLLOWING: ? ONE (1) ORIGINAL SIGNED APPLICATION O ONE (1) COPY OF A SCALED SITE PLAN DRAWN IN INK indicating all current and proposed land uses, structures, and other site improvements. Additional documentation may be required for various types of projects. Partial or incomplete applications and drawings cannot be processed and will be returned to the applicant by mail. APPLIC T ALI GNAT RE: I DATE: _ q FOR OFFICE USE ONLY CASE NUMBER DATE CASE NUMBER DATE CASE NUMBER DATE NOTES: 13,reen All Service St"'uctures R.g chanical Units PER cli-Y CODE ZONING INSPEC7IONPREII(JIR~D UPON COMPLETION? ? YES O If yes, please call 614-410-4680 to schedule an inspection. A Ce ficate of Zoning Compliance will be issued after the work is inspected and approved by Land Use and Long Range Planning. ? APPROVED e PROVED AS NOTED This Certificate of Zoning Plan Approval is issued for, and in referee to the property and use described above, and as approved by the City Administrator or d'71 the City Council, Boar I Zoning Appeals, Planning & Zoning Commission, or the Architectural Review Board as appropriate- ? DIS ROVE BY. ! DATE: CERTIFICATE OF ZONING PLAN APPROVAL 3/10/2006 CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 Walk Through e of Review Building Fire Zoning (This is not a building permit) Application Date: 4/7/2008 Application Number: 08 -200316 Property Address: 655 METRO PL S Project Description: MCGOWAN #580 Fire Alarm Application No.: Fire Suppression Application No.: CEO ZaQ SZ Sprinkler System Required: System Demand: Special Hazard Classification: Square Footage: 9 d $ Occupancy Load: Construction Type: ~j Use Group: Result of plan review: ~pproved Submit signed changes/revisions prior to: Disapproved, reschedule walk through with revised documents Disapproved, resubmit under the regular permit process The following items must be addressed: 1. Field verify existing, additions and changes to horn/strobe location and actuation 2. Field verify emergency egress and exit lighting 3. All fire protection systems require a separate permit 4. FI M D VM4 y ~G ty-~-`'2t- Ce V Q oca.~E. ~C't~- V!/1.C7 5. 6. 7. 8. Reviewed by: CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 wa gh Notice of Review Buildin Fire Zoning This is not a building permit) Application Date: 4/7/2008 Application Number: 08 -200316 Property Address: 655 METRO PL S Project Description: MCGOWAN #580 Fire Alarm Application No.: Fire Suppression Application No.: Sprinkler System Required: System Demand: Special Hazard Classification: Square Footage: 06 Occupancy Load: Construction Type: Use Group: Result of plan review: l/Approved Submit signed changes/revisions prior to: Disapproved, reschedule walk through with revised documents Disapproved, resubmit under the regular permit process The following items must be addressed: 1. Field verify existing, additions and changes to horn/strobe location and actuation 2. Field verify emergency egress and exit lighting 3. All fire protection systems require a separate permit 4. S CA (t cw 5 ~1 IM . U-) 6. 7. 8. Reviewed by: Ile, CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 Walk Through Notice of Building Fire o n i , (This is not a building permit) Application Date: 4/7/2008 Application Number: 08 -200316 Property Address: 655 METRO PL S Project Description: MCGOWAN #580 Fire Alarm Application No.: Fire Suppression Application No.: Sprinkler System Required: System Demand: Special Hazard Classification: Square Footage: Occupancy Load: Construction Type: Use Group: Result of plan review: ftproved Submit signed changes/revisions prior to: Disapproved, reschedule walk through with revised documents Disapproved, resubmit under the regular permit process The following items must be addressed: 1. Field verify existing, additions and changes to horn/strobe location and actuation 2. Field verify emergency egress and exit lighting 3. All fire protection systems require a separate permit 4. Screen All 0rNFiC " 5. - & Meeh-nical-Ul ItS 6 PER CITY CODE CALL PLANNING DIVISION 7. i - 8. Reviewed b : CIP(OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 Supplement to Walk-Through, Plan Approval Application Date: 4/7/2008 Application Number: 08 -200316 Property Address: 655 METRO PL S Project Description: MCGOWAN #580 THIS IS NOT A BUILDING PERMIT. IT IS A SUPPLEMENT TO OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT This SUPPLEMENT TO THE PLAN APPROVAL is issued by the City of Dublin, Division of Building Standards. Listed below are items which may not appear in the construction documents, but which are not considered to constitute a hazard serious enough to warrant withholding Plan Approval. The following items are conditions of the issuance of the Plan Approval,, when applicable Item 1. OBC. 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the the building official or the building official's designated representative. Item 2. OBC 105.7.2 Posting. The certificate of plan approval shall be posted in a conspicuous location outside of the building and in the front part of the premises on which is, or will be the approved building or equipment to which the approved plans relate. The owner and the contractor shall, so far as possible, preserve and keep the certificate posted until the completion of the work to which the approved plans relate. Item 3. OBC. 106.4 Amended construction documents. If substantive changes to the building are contemplated after first document submission, or during construction, those changes must be submitted to the building official for review and approval prior to those changes being executed. The Building official may waive this requirement in the instance of an emergency repair or similar instance. Item 4. OBC 109.1 General. Construction or work for which an approval is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. This includes firestopping and draftstopping (Chapter 7 OBCJ, mechanical work piping, ducts and systems Chapter 3 OMCJ, structural members and connections (Chapter 16, OBCJ, and electrical work Chapter 27 OBCJ. Existing electrical conductors, If removed, abandoned, or altered, shall be accomplished to the electrical field inspector's approval. Electrical work found not to meet the code's standards shall be corrected to the electrical field inspector's approval. All systems and elements covered by code are to be inspected and approved before being covered. Page 1 of 2 Item 6. OBC 1 103.1 Where required. Building and structures, temporary or permanent, including their associated sites and facilities, shall be accessible to persons with physical disabilities. OBC 1 103.2.1 Specific requirements. Accessibility is required in building and facilities, or portions thereof, to the extent indicated in ADAAG Section 4.1 and this chapter. The start of construction indicates acceptance of all the conditions listed above. This review does not preclude the necessity to conform to provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rest with the registered design professional, the tenant and the owner. Plan Approval will be valid only upon receipt by the City of Dublin, Building Standards, of one signed copy of the addendum to the submitted plans. TO REQUEST AN APPEAL HEARING, YOU MUST send a written request, listing the items to be appealed and the relief sought and one copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016-1236 Re ' wed and Signed, Ray M. H pham, AIA Jeffrey S. Tyler, AIA Commercial Plans Examiner Chief Building Official City of Dublin City of Dublin Signature - Architect Engineer or Contractor Date Print Name and Title as Signed Page 2 of 2 CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone., (614) 410-4670 * Inspection Line: (614) 410-4680 Walk Through Notice of Review Building Fire Zoning (This is not a building permit) Application Date: 4/7/2008 Application Number: 08 -200316 Property Address: 655 METRO PL S Project Description: MCGOWAN #580 sZ' Fire Alarm Application No.: Fire Suppression Application No.: 0.p Sprinkler System Required: System Demand: Special Hazard Classification: Square Footage: 9 0 g Occupancy Load: Construction Type: 113 Use Group: Result of plan review. Approved Submit signed changes/revisions prior to: Disapproved, reschedule walk through with revised documents Disapproved, resubmit under the regular permit process The following items must be addressed: 1. Field verify existing, additions and changes to horn/strobe location and actuation 2. Field verify emergency egress and exit lighting 3. All fire protection systems require a separate permit p 5. 6. 7. 8. Reviewed by: Document created/Revised 1/1/08 CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 W gh Notice of Review g Fire Zoning (This is not a building permit) Application Date: 4/7/2008 Application Number: 08 -200316 Property Address: 655 METRO PL S Project Description: MCGOWAN #580 Fire Alarm Application No.: Fire Suppression Application No.: Sprinkler System Required: System Demand: Special Hazard Classification: Square Footage: 06 Occupancy Load: Construction Type: Use Group: Result of plan review: (./f~Approved Submit signed changes/revisions prior to: Disapproved, reschedule walk through with revised documents Disapproved, resubmit under the regular permit process The following items must be addressed: 1. Field verify existing, additions and changes to horn/strobe location and actuation 2. Field verify emergency egress and exit lighting 3. All fire protection systems require a separate permit 4. S C 'Cr CSC PM mqj4yu- 6. 7. 8. Ke V V Reviewed by: Document Created/Revised 1/1/08 CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 Walk Through Notice of Review Building Fire onil g (This is not a building permit) Application Date: 4/7/2008 Application Number: 08 -200316 Property Address: 655 METRO PL S Project Description: MCGOWAN #580 Fire Alarm Application No.: Fire Suppression Application No.: Sprinkler System Required: System Demand: Special Hazard Classification: Square Footage: Occupancy Load: Construction Type: Use Group: Result of plan review: ~~)kpproved Submit signed changes/revisions prior to: Disapproved, reschedule walk through with revised documents Disapproved, resubmit under the regular permit process The following items must be addressed: 1. Field verify existing, additions and changes to horn/strobe location and actuation 2. Field verify emergency egress and exit lighting 3. All fire protection systems require a separate permit 4. screen All service 5. n w e aWeal Units 6. PER CITY CODE CALL PLANNING DIVIS! N 7. 8. Reviewed b : Document Created/Revised 1/1/08 CERTIFICATE OF ZONING PLAN APPROVAL APPLICATION # l~ DATE ISSUED-J1 Land Use and Long Range Planning 5800 Shier-Rings Road Dublin. Ohio 43016-1236 Phone/ TDD: 614-410-4600 Fox; 614-410-4747 Web Site: www.dublin.oh.us NAME OF BUSINESS/ FACILITY (IF APPLICABLE LG70t?f ADDRESS OF SUBJECT PROPERTY NAME OF PPLICAN e- I T/ AU 0 IZED AGENT ufl PHONE 7'- t ADDRESS OF APPLi ~AN1T/ AUTHORIZED AGENT W1.1-L~!?G PL 0.0 ~?~lo NAME O PROPERTY OWNE / 4.*17# - PHONE a&57 oItJ~tl~ ' PLEASE DESCRIBE IN LAYMAN'S TERMS THE EXISTING AND PROPOSED USE(S) OF ALL PARTS OF THE LAND AND/OR BUILDINGS. IF A it CHANGE OF USE IS PROPOSED, PLEASE EXPLAIN. (IE, RETAIL SPACE TO MEDICAL OFFICE SPACE, ETC.) /mlooeI 4 nwwwr PLEASE SUBMIT THE FOLLOWING: ? ONE (1) ORIGINAL SIGNED APPLICATION ? ONE (1) COPY OF A SCALED SITE PLAN DRAWN IN INK indicating all current and proposed land uses, structures, and other site improvements. Additional documentation may be required for various types of projects. Partial or incomplete applications and drawings cannot be processed and will be returned to the applicant by mail. APPLIC T GNAT RE: DATE: FOR OFFICE USE ONLY CASE NUMBER DATE CASE NUMBER DATE CASE NUMBER DATE NOTES: @{ p+ PEI1 C11Y CODE 'TNI'IEAMING DIVISION ZONING INSP R O ED UPON COMPLETION? O YES Afficate 0 If yes, ple ase call 614-410-4680 to schedule an inspection. A Cerof Zoning Compliance will be issued after the work is inspected and approved by Land Use and Long Range Planning. ? APPROVED ROVED AS NOTED This Certificate of Zoning Plan Approval is issued for, and in refere a to the property and use described above, and as approved by the City Administrator or de 'gn", the City Council, Boar f Zoning Appeals, Planning & Zoning Commission, or the Architectural Review Board as appropriate- 1 DIS ROVED AS NC Ep BY: DATE. - A CERTIFICATE OF ZONING PLAN APPROVAL 3/10/2006 or: • s GENERAL ARCHITECTURAL NOTES BUILDING CODE DATA ~~E Gj~.• JEIyNIFER • 1, GOVERNING CODE -OHIO BUILDING CODE 2007. 13. IN ANY ROOM IN WHICH PLUMBING, HEATING, OR ELECTRICALALTEAATIONS ARE MADE, THE CONTRACTOR AEQUIRVNG CUTTING INTO EXISTING WORK SHALL p~gWNEII.; , . , 2, THIS IS A "BUILDERS SET" OF DPAWINGS. THE ARCHITECT'S RESPONSIBILITY MAKE PROPER REPAIRS TO OTHER BUIV.DING ITEMS AFFECTED (LE., FLOORS, USE GROUP - B IS LIMITED TO THE ITEMS SHOWN ON THE ARCHITECTURAL DRAWINGS, OBTAIN. WALLS, CEILINGS, BASE, CHAIR RAIL, TRIM ETC,). CONSTRUCTIONTYPE - I B OCCUPANCY • OFFICE ~ ARCHITECT'S SPECIFIC APPROVAL PRIOR TO DEVIATING FROM THE DRAWINGS, IT SHALL BE THE CONTRACTOR'S SOLE RESPONSIBILITY TO COMPLY WITH 14. ALL CONNECTIONS ARE TO DEVELOP THE FULL STRENGTH OF THE FRAMING ••••e STANDARD BUILDING AND CONSTRUCTION PRACTICES AND AND MEMBERS, UNLESS OTHERWISE APPROVED, MANUFACTURER'S RECOMMENDATIONS FOR ALL ITEMS NOT SPECIFICALLY 15. BOLTING OF WOOD TO STRUCTURAL MEMBERS OR MASONRY SHALL BE IN ALL DRAWINGS IN THIS SUBMITTAL HAVE BEEN PREPARED UNDER INDICATED AND DETAILED ON THE DRAWINGS. FOLLOW THE BEST TRADE GENERAL WITH A MINIMUM OF 1J2" DIA, ANCHOR BOLTS AT 4'-0" O.C. EXCEPT THE 2007 EDITION OF THE OHIO BUILDING CODE AND IN PRACTICES AND ENGINEERING FOR THE ITEMS NOT SPECIFICALLY DETAILED WHERE SHOWN OTHERWISE. SITUATIOiNS REQUIRING SPECIAL BOLTING SHALL AND INDICATED. BE WITH THE SIZE AND SPACING OF BOLTS TO SUIT THE CONDITIONS, ACCORDANCE WITH THE 2007 EDITION OF THE OME, OPC, AND NEC. ANCHORING OF WOOD TO STRUCTURAL MEMBERS, OR CONCRETE SHALL BE, IN ~ ~ 3. DIMENSIONS SHOWN ARE FINISH FACE OF DRYWALL TO FINISH FACE OF GENERAL, WITH STRAP ANCHORS FIXED IN PLACE WITH EXPANSION ANCHORS DRYWALL. OR POWER DRIVEN ANCHORS, THE EXISTING BUILDING IS TOTALLY SPRINKLED PER OBC AND NFPA-13. 4, ALL DIMENSIONS SHALL BE VERIFIED AT THE JOB BY THE GENERAL 16. PROVIDE LINTELS OR HEADERS OVER ALL N ~ CONTRACTOR AND EACH SUBCONTRACTOR. THE ARCHITECT MUST BE OPEN( GS INCLUDING THOSE REQUIRED FOA DUCTWORK, PIPES, LOUVERS, GRILLES, DAMPERS, ETC. NOTIFIED OF ANY DISCREPANCIES PRIOR TO COMMENCING WORK, EMERGENCY POWER FOR EXIT SIGNS AND EMERGENCY EGRESS Q 5, THESE DOCUMENTS WERE PREPARED ON THE BASIS OF EXAMINATION OF 11. FILL ANY MASONRY VOIDS WITH MORTAR OA CONCRETE WHERE ANCHORS LIGHTING IS PROVIDED THROUGH AN EXISTING EMERGENCY GENERATOR, o VISIBLE PORTIONS OF THE EXISTING STRUCTURE. THE ARCHITECTS( _ OCCUR. ENGINEERS ASSUME NO RESPONSIBILITY FOR ANY SITUATIONS, DIMENSIONS, ~ 18. NOT USED THE EXISTING BUILDING HAS AN ENUNCIATED AUTOMATIC FIRE ~ OR OTHER CONDITIONS OF THE EXISTING STRUCTURE WHICH MAY ARISE PROTECTIVE SIGNALING SYSTEM, WITH LOBBY AND STAIR PULL _ DURING DEMOLITION OR CONSTRUCTION. 19,NOT USED STATIONS, AND AUDIBLE AND UISUAL ALARMS IN ALL PUBLIC ~ 6. SHOULD ANY OF THE DETAILED INSTRUCTIONS SHOWN ON THE DRAWINGS SPACES. ~ CONFLICT WITH THESE NOTES, STRUCTURAL NOTES, THE SPECIFICATIONS, OR ~ 0 WITH EACH OTHER, THE STRICTEST PROVISION SHALL GOVERN, 20. EQUIPMENT FRAMING LOADS, OPENINGS AND STRUCTURE IN ANY WAY RELATED TO HVAC, PLUMBING, OR ELECTRICAL REQUIREMENTS ARE SHOWN 7, THE GENERAL CONTRACTOR SHALL COMPLY WITH ALL BUILDING CODE FOR BIDDING PURPOSES ONLY. CONTRACTORS SHALL OBTAIN APPROVAL Of • ~ REQUIREMENTS THE LOCAL GOVERNING AUTHORITY, AND SHALL OBTAIN AND THE TRADES INVOLVED BEFORE PROCEEDING WITH SUCH PORTION OF THE ~ ~ ¦ ~ PAY FOR ALL REQUIRED PERMITS, FEES, AND INSPECTIONS, WITH THE WORK, EXCESS COST RELATED TO VARIATION IN THESE REQUIREMENTS ARE TO . EXCEPTION OF FEES REQUIRED FOR THE PLUMBING, HVAC, AND ELECTRICAL BE BORNE BY THE APPROPRIATE CONTRACTOR, ~ ~ PORTIONS OF THE WORK, WHICH ARE THE RESPONSIBILITY OF THE RESPECTIVE SUBCONTRACTORS. 21, ALL EQUIPMENT FURNISHED AND WIORK PERFORMED UNDER THE CONTRACT DOCUMENTS SHALL BE GUARANTEED AGAINST DEFECTS IN 8, IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW THE MATERIALS AND WORKMANSHIP FORA (PERIOD OF ONE (1) YEAR FROM THE APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF DATE OF FINAL ACCEPTANCE. ANY FAILURE OF EQUIPMENT OR WORK DUE TO DRAV~/ING INDEX CONSTRUCTION. DEFECTS IN MATERIAL OR WORKMANSHIP SHALL BE CORRECTED BY THE 9. PERFORM DEMOLITION AS INDICATED ON PLANS AND DETAIL N A CONTRACTOR AT NO COST TO THE OWhNER, SAD S REQUIREDFORTHECOMPLETIONOFTHEPROJECTASINDICATED.SCHEDULE 22, NOTUSED 5980, VV~~CQx~ ~~C~Ce~' ~fb~~n ~h)~ ~j I h - ~ G0,01 COVER SHEET i Q 3 .6147 AND PERFORM DEMOLITION PROCEDURES TAKING NECESSARY PRECAUTIONS ' 614-792-1000, Fix 614-79Z-1001. sP,o1 sITEPLAN TO PREVENT WATER DAMAGE TO THE EXISTING STRUCTURE At01 DEMOLITION PLAN, NEW WORK PLAN, FINISHES, PLUMBING 10. DO NOT CUT OR PATCH ANY WORK THAT WILL IMPAIR THE STRUCTURAL 23. NOT USED ' . DIAGRAM, POWER PLAN AND LIGHTING NOTES LOAD CARRYING CAPACITY OR REDUCE THE LOADIDEFLECTION PATIO, 24. COORDINATE LOCATIONS AND10R ELEVATIONS OF FLOOR DRAINS, 11. PROVIDE ADEQUATE TEMPORARY SUPPORTAND SHORING FOR WORK REGISTERS ACCESS PANELS GRILLS LOUVERS CONVECTORS CABINET UNIT BEING CUTAND PATCHED TO PREVENT FAILURE. PROVIDE ADEQUATE HEATERS PANELS ETC. WITH MECHANIIICAL AND ELECTRICAL CONTRACTORS. PROTECTION OF OTHER WORK DURING CUTTING AND PATCHING TO PREVENT ' DAMAGE. CUT WORK BY METHOD LEAST LIKELY TO DAMAGE RETAINED AND 25. IN GENERAL, NEW MATERIALS AND MATERIALS FOR REPAIR CONDITIONS ADJOINING WORK. SHALL MATCH 51MILAA ITEMS IN QUALITY, DETAIL, PROFILE, AND FINISH AS THOSE ALREADY BUILT INTO THE WORKA. 12, CUTTING INTO NEW WORK OF OTHER TRADES OA INTO THE EXISTING STRUCTURE SHALL BE PERFORMED BY THE TRADE REQUIRING THE CUTTING. 26. PATCH ALL WALLS, FLOORS, AND CEILINGS AND PROPERLY PREPARE ALL ALL CUTTING SHALL BE DONE IN A NEAT MANNER USING SAWS WHERE SURFACES FOR NEW FINISHES. PATCH'WITH SEAMS WHICH ARE DURABLE AND L~ POSSIBLE. ANY DAMAGE TO THE WORK OF THE OTHER TRADES OR TO THE AS INVISIBLE AS POSSIBLE, COMPLY Wll'H SPECIFIED TOLERANCES FOR THE EXISTING STRUCTURE IN EXCESS OF THE CUTTING REQUIRED, WHICH, IN THE TYPE OF WOPK BEING DONE. RESTORE: EXPOSED FINISHES OF PATCHED AREAS OPINION OF THE ARCHITECT, IS DUE TO NEGLIGENCE, SHALL BE, REPAIRED AT AND, WHERE NECESSARY, EXTEND NEWJ FINISH RESTORATION ONTO ADJOINING THE EXPENSE OF THE TRADE WHO DID THE CUTTING, ALL PATCHING AND RETAINED WORK IN A MANNER WHICH VNILL ELIMINATE EVIDENCE OF PATCHING, PAINTING AS A RESULT OF THE CUTTING AND NOT TO THE NEGLIGENT ACTION 27. NOT USED N G M I T H screen AIII ~~rvice S~r~¢ct~res & Mechanical Units (n SHALL BE DONE BY THE CONTRACTOR AT HI5 EXPENSE. PER CITY CnDE _ E R V I C E S CALL PLANNING DIVISION Z ~ ~ ~ W z 0 ~ ~ W W • • ~ > ~ 0 ABBREVIATIONS ~ n. ~Q o _ ~ I~ ~ ' AFF ABOVE FINISH FLOOR EWC ELECTRIC WATER COOLER MFR MANUFACTURE (R) REV REVISION (S), REVISED ADJ ADJACENT EL ELEVATION MAR MARBLE ROW RIGHT OF WAY AIC AIR CONDITIONING EQ EQUAL MAS MASONRY RD ROOF DRAIN z V W ALT ALTERNATE EXIST EXISTING MO MASONRY OPENING RM ROOM 311 ALUM ALUMINUM EB EXPANSION BOLT MAX MAXIMUM RO ROUGH OPENING ~ ROOM NUMBER 1-0° 1~ DIMENSION LINE Q U ~ , AB ANCHOR BOLT EXP EXPOSED MECH MECHANIC (AL) SCH SCHEDULE OFFICE • ~ z ~ ANOD ANODIZED EXT EXTERIOR MTL METAL SEC SECTION ASPH ASPHALT FOC FACE OF CONCRETE M METER (S) SHT SHEET BRG BEARING FOM FACE OF MASONRY MM MILLIMETER (S) S1M SIMILAR BPL BEARING PLATE FOS FACE OF STUDS MIN MINIMUM SC SOLID CORE BM BENCH MARK FIN FINISH (ED) MIR MIRROR S SOUTH 100 DOOR NUMBER FINISH FLOOR ELEVATION • ~ BIT BITUMINOUS FE FIRE EXTINGUISHER MLD MOLDING, MOULDING SPEC SPECIFICATION (S) MAF'~Ut'~T a~:aam BLKG BLOCKING FEC FIRE EXTINGUISHER CABINET MT MOUNT (ED), (ING) SQ SQUARE BD BOARD FLR FLOOR (ING) NAC NOISE REDUCTION COEFFICIENT SS STAINLESS STEEL R _ / 600 fi BOT BOTTOM FD FLOOR DRAIN NOM NOMINAL STD STANDARD r 1,~ ~ ~ ~jte~ald f'V.r'iy BLDG BUILDING FTG FOOTER N NORTH STL STEEL ~ _ 1 SECTION INDICATOR 1 CAB CABINET FND FOUNDATION NIC NOT IN CONTRACT SD STORM DRAIN A1.01 REFERENCED SHEET NUMBER 1 INTERIOR ELEVATION INDICATION ~ ~ 4° PROJECT; 08120.050 CB CATCH BASIN FR FRAME (D),(ING) NTS NOT TO SCALE SUSP SUSPENDED REFERENCED NUMBER ~ f, . ~ } DATE; 4108108 CLG CEILING FUR FURRED (ING) OC ON CENTER (S) SYM SYMMETRY ((CAL) CEM CEMENT GA GAGE, GAUGE OPG OPENING TEL TELEPHONE DRAWN BY: MK ft ~ y ~ ~ ;sa ~6~';• " ;tea 1e~ - CHECKED BY; CRH CM CENTIMETER (S) GL GLASS, GLAZING OPP OPPOSITE TU TELEVISION ~ ~ a:i CT CERAMIC TILE GB GPAB BAR OPH OPPOSITE HAND TNK THICK / A COL COLUMN HDW HARDWARE OD OUTSIDE DIAMETER T & G TONGUE AND GROOVE ~ DETAIL INDICAT A i' ~ ~ ~ ~ I CONC CONCRETE HTG HEATING OH OVERHEAD TSL TOP OFSLAB ~ OR ~ SET NUM: COLUMN GRID ~ I( ! I CMJ CONCRETE MASONRY UNIT HVAC HEATINGNENTILATIONI PNL PANEL TST TOP OF STEEL 1 ~ ~ REFERENCED SHEET NUMBER CONST CONSTRUCTION AIR CONDITIONING PTN PARTITION TW TOP OF WALL AL01 ~ ' ~t Ii _y Shlzr,Pln~ kd r'~ ,~~`1 ~ - t I ~ ~e PRINTED; CONT CONTINUOUS OR CONTINUE HT HEIGHT PVMT PAVEMENT TB TOWEL BAR ~ ~ ~ r ~W` M~aJ~ N i CONTR CONTRACT (OR) HC HOLLOW CORE PLAM PIASTIC LAMINATE TYP TYPICAL CJT CONTROL JOINT HM HOLLOW METAL PL PLATE UR URINAL ~ ' ~ ' REVISED: a ~ j &ilonur<gb ~d ` CORR CORRUGATED HOR HORIZONTAL PLYWD PLYWOOD UB VAPOR BARRIER 1 CRS COURSE (S) HB H05E BIB PVC POLYVINYL CHLORIDE VERT VERTICAL _ _ _ A1,01 1. 1. ~ 1 ~ ~etm PIS ~ ' ~,1~I,F ti~ ~~ti CFT CUBIC FOOT HWH HOT WATER HEATER PCF POUNDS PER CUBIC FOOT VB VINYL BASE CYD CUBIC YARD ID INSIDE DIAMETER PFL POUNDS PER LINEAL FOOT UCT VINYL COMPOSITE TILE ENLARGED PLAN REVISION ~ ? ra~~- DL DEAD LOAD INT INTERIOR PSF POUNDS PER SQUARE FOOT WC WATER CLOSET ~ ( REFERENCED SHEET NUMBER DTL DETAIL INV INVERT PSI POUNDS PEA SQUARE INCH WP WATER PROOF IING1 ~ i t ~ 1 ~ DIM DIMENSION JT JOINT PL PROPERTY LINE WWF WELDED WIRE FABRIC - - - I ~hOVdlfq~ t DIV DIVISION LAB LABORATORY RA RETURN AIR W WEST DR DOOR LB LAG BOLT RAID RADIUS W WIDTH, WIDE DS DOWN SPOUT LAM LAMINATE (D) REF REFRIGERATOR W/O WITHOUT DWG DRAWING IAV LAVATORY RET RETURN WD WOOD E EAST LH LEFT HAND ppE: Pt Aga Oucst Inc Ml CFuGs 02007 N So 2L p, app' vlkgwTd:Atl s° ELEC ELECTRIC LL LIVE LOAD NORTH ARROW MAT MATERIAL (S) MH MANHOLE N GOmOl SITE LOCATION MAP ; . . r ~ ~ , . , . • i , ; . . , . _ • ..y i ~ ~,i` ' ' P it , . ' , a • . r ,:1 PARCEL. 3 y.t+° yt t. , a+ , , , , • , • ' • ~ Together ,with, d perpetual ,11vn-excltisive•:egsement :and ri ht-of-wa fo r' j . . , , S , • 9 y r pu poses of ingress prld egress; drassin~` Reseru~,.0 a~'i1~~troC2iafei and ,exfen in ' ~ `f dg • rom,Metro.Ploce I~brth to ttfe:hereirrldeScribed:,6,327 Acre..Tract of Lnnd, and grunted and cbrlveyed:b`':Metr`oCehtar' weer , ~ . , ~ . DOTE -THE FOL OW1NG; EASEMENT'S DO NOr` APRiY ..TO.' SUBJECT; PROPERTY ° . ~ti . , ~ , y, ~ , .s Assndlatibn Inc';. to 711e Pruden. • tial. lnsuronce ~orrpony, of J;m~r'ica by. a~ deed •tif easement recorded;;iti .peed.8ook Vo(utne 3T41; page 35:1, Recorder 5 afff~a, Fr`a {<1in. Co ri:. a . _ . , , , p~ w . ~ I;,t Gam :a D 03 . , n m. ~1 P`~256 -Pol Line: Easemen#: to~~the Coiumbus:Railwa o er.. .L ~ 0 ~ ~ , • ~ U ty, Oh n , , . ; . ' ~ ~ Y • I`e Lin a§ei~' t ta>Sau.tt7ern nhio:,Efectric.Com'`an ir~.0.gi;::112T P 314. --Po , 8 E.. ~n , . R,,. y . . . . . . 9 • , . ~s' . ~ ; : ,1 'd i ' S+tug4ed in the Stote of:~Ohio, Couhly of. Franklin, Ulloge Of.Oublan: a ~ ' . P~ -Pole ine. Ease` en to 5put err1.01iia Electric C~m'dn m D'$;:~1.98 657: ~ . , L m, .t , , h Y.. 9 . , p t • • , Aeirg of strip •of (and twenty=four, (Z4} .feet m• wid#h .across: L'at .6 oW "Metrocenter , as the tat of same i I a 0 io. iri'D. 2 6 62 -Ch nne Easeme he•'S e Oh B. a tit tat t , P 9~ , er s Olf s of recoed ~p Plat 8oo(i 55, Pdge~, 8 & 9~.•.I~ecor-~ ~ ' d five„ Franklin County, Ohio; ;the centerline.af a0i~ stcip•. b~ir~g,.described, os follows: ° F I' f -Easement .to~ li Columbus ~ SouChem Ohio E{kctnc, Gom arf' "n D,B., 2684 'P :697 , to P Yi ~ Aeginnir~g ,ate e point in the souther)q righf.~-of~way tine, of ,Metro Place North .(being' 60 feet in width.), sold pplnt'6e1n .located.. : ~Ri ht-of Wa to Columbio' Gas Of.,Ohio Ind , ~n b.B,; 12742 P 152 _ . .9 Y „ ; 9., , ~ , r 9 . ~lorti 80 3;3' ' W~s.t 30:0 • • • . feet frolm the northeosterly corner of soie;l.ot 6, the northwesterly corner of Reserve °G'; 52 ' • , r ~ y Easement fo the Columbus & SouYhsrn Ohio, Iect ~c ,Carn an ~ im D.B. 2957 P 65b Q , ~ . ~ t, p Y. ' ' ~ Thence South.9' 26' 08" West, 170 0`#ee.t'to a point of cutybtere of. a cutve to the right; ' , - ~ . • . 5... Pg, 126.= ,Easement to Tlie Ohio;-Bell Telephone Company in.D..6, 300 Ri h.t:-of Wa fa. C9lvmbia Gas. Of:Ohio; lnc:. m D.B,'3085 P 299 'Thence, along tfie'arc of said curve Deltb - 55 Ob' b6", Rddfus = , , ( 40,0 feet), o 'chord bearing and distance of ~out,h ~6' 56 41 ;West, 36:95, feet to a point oil tangency, . ' 9 Y _ 9~ 9A, • -Eosement. to. t e oluintius & Southern 0 io~ El ctric"Com an , in D ~ .:313'4 P :437 ~ • h C h ~ p..Y ' g. , ,Thence South 64' 2T 14" West;, 2 46 Meet to the. point of terminus in the easterly line of lot' S, said point of tefminus be}tg laCofed Soutti• 5' S0' S~° East, -Eaaement..to the Vino e Of Dublin- in D B. 3403, P ,.898. •.~...ME~R 9 . 9. Q . 36.76 fleet from the northeasterly corner.,.of said Lat. • C Easement to' th,e Columbus & Southern Oliio Dlectric Com `an .ih• D.B, 3434, P ..328 ~ N T ~ R p Y... 9 , . • . LOt .3 . PARCEL 5 -Eosa'ment to,tlae Vi1l.age`Of. Dublin; :in p.8, 3765,• Pg: 124 ` ~ ~ $ 83• ~ a, " • P,. j~• Together with, the perpetue(,. non-exclusive reciprocol easements and rights-of-woy for purposes 'of ingress and, egress, and for the purpose of constructing, _ semeni to C f ti °n hi' ~ I .c i Com i 3.7 P ~ ~ Eo o umbus Shut er O o E e fr c, , p.9ny n D B 92, q, 870 261, - --...~---10 Ease 66 hoeing ws„ng and mointain'ing common dtivev+oys, os described. in two instruments entitled "Reciprocol Deed .,of Eo ements. for Ingtess, and, Egress and Common' -Easement to Columbus Souaher.n Power Com an ~n!OR..l3$41:A: 07. . ~ O,R; P Y. , . ~ ~ ~ 79 A ?0 Driveways executed by and between'tfie Prudential. Life Insuranee Company of America and MetroGenter.A'ssociates on Jul~+,25, 1:97,9; arid'"recorded in peed Aook Volume, 3T41, Poge 364, and on June 18, 1980. and reccbrded in Deed Bdok Volume.37.99, Poge 750,, Recarders,Office,..Fro.nklin, County;. Ohio. : , . -a,,, . i ~ ;y , . • N0. 2542 ~ . , _ . M, S. N~• 241 • , ~ ~ ~ . / ~ ? ; O~ i>\ ~ / i3lgn.ket•'Ease ~ Fas i ~,u% ~ / 08454. p 20. ~t o-' , , ~ . S Pg SS ~$t7 64, 6 oR ~9e&~ s . ; ' Mifitar~{ S ~rve.InNohe State of Ohio, County of Franklin, City ofDublin, being located in Virginia i r ,r ~6 Y y 2419 and being 14.968 acres of Lot 9 af" AMENDED SUt3DIV1~IQN OF PART ` ~ OF; LOT 4 & ADDITION TO METROCENTER", as the plat of same, is of recofd in Plat Book 57; • ~ ~ ~ < .Page 36, ail references being to records in the Recorder's O.ffics,,:Franklan .Cnunfy, Ohao, and i bounded and described as follows ; W / X , r r,( ii . 0 % x.' ' ~ ~ ~ 1~ • ~ ~ Beginriirig of a fio'int in the westerly right-of--way line •of' M. etro P1dce South (being 60 , ~ w / ` ~c . feet in width), at• the northeasterly corner of Lot af• "METROC~NTER", as• ~he.•plat~ of same ~ I / is af. record in Plat Book 55, Pages $ & 9; ~ ~ • i ~ i 05 • \ , \ ~ ~ thence clan said ri ht-of~-wa i'n ~ . r ~ 9 g y leaf Mefro. Wiace South being the are of a curve, to. ~ ~ .the left (Sub „Delta. = 53'47'27, Radius = 480.0 feet), a, chord be4ring 'bnd dlsta:nce of i' 0 d ' ~ • ~ I Sauth: 3'53,52 Wes#; .434,26 feet to a point; . , • • ~r ~ \ • ` ~ / thence South 55'35'49" West, 443.99 feet to' a point; \ ~ / A / N ~ ~ • ~ I thence North 81'39'31" West, 690.00 feet to a oint in' the caste l ~ li it a P r y m ed ccess~ • ~O ~ \ nght-of--way line of interstate Route 270; . 4 ~ ~ y N / ~x' ~ ~ t. ~ ~ V ~ , ~ \ thence along said right-af-way line of interstate Route` 270, being the arc. of'a. curve 'y ~ ~ ~ A f ~ \ v ~ i ~ ~ - ' to the right Sub-Delta = 0'53'02", Radius = 7323.36 feet.)., ,a chord bearing and dis~• ' tance of North 17'28'08" East, 112.98 feet to a point of tangency; . \ \ . ~ ~ \ k ~ • , c, ~ thence continuing along said right-of-way line, the following :courses.:gnd, distances;,:.: ~ , • , ~~'y c ~ ~tr f a ~~yy or#~ ~q4 + ~ y o, `D 9 "t4~f1 t"tin o° cS ~~r7f~~ 41 t~t • e 6' r , r„. > oar.,.@. ~.r.... . r ~ .'N 1. + ~ fi 4 ~ ~ { ~4 North 28`05' 4 e#. to a point;, _ _ . - 38" East,, 29.7 fe and • ! ~ r r , . , i~ , ~ ~ ~.F.y% , t ,},M , ~Nor.th 30'21 53 East; ,1,47,84 feet to the•soukhwesterly corner,,of l.dt 3 a1!'".METRO Office ~i'. ' a >9uiltling a o ~ ~ CENTER , : ~ ~ • o. ~H \ • 6fanket EaS mo. ,N.. 655 ~ ~ . O.R:' 0845 emeitt • . 2a,~s~ ~ ~ ~ . L1 = 53'4~7'23~ ~ th.ence along the southerly line of said' Lvt 3; .south' 83'30'45".f Ea~fi 26"t~6;6: feet.. to : , ~ R ~ 480, 00 - ~ . an angle point ia'1: sold iirie; Blanket Easemen S' Q3'S3 52 ; W 3lanket Easement Ch, = 4,3.4,26' thence continuing along said southerly line', South 71"2$'4~° East, 486;64 feet ko. the n { o O.R. 48484. ).R. 48484. p 20 I. • d N D 2C ~ ~ ' place of beginning, containing 14.968 acres; Fiore oc less, ~ 23,00' • t~ • • ~ ~ , \ . , ss gyp. • • \ ' • 9 . ~ ~ , , • t ~ \ ~ • ' • ~ SURVEYED & PLATTED ~ ' ` ~ BY \ n ~ ~ ~ iK\ 4 \ ! e,' i . _ ~ ~ w ~ Stl CONSULTING £NGIN££RS SURI~'YORS 170 MILL S1R£ET ' GANANNA, ONlO 4,3230: • ~ ~ ~ ` y , ~ ` ~ ~ , X614}' 471=515Q . . _ . We hereby, certify to Great Lakes REIT, L.P., aDelav~are. Limited Partli,ership, Great Lakes REIT Ina,, a Maryland Corporation and Commonwealth .Lund Title Insu-ranee Corri:pany , / ~ that the attached survey shows the locution of all buldffigs; structures and other impr:avements sit ~ ` , uated an the premises and that except as shown there are. no vi~;ible easements or rights-of-ways . across said premises or any other easements or rights--of~-ways ,o.f whletl the undersigned has k7.een. ' advised, no encroachments on adjoining premises by any of said bail.dings; structures or other im- i \ \ f ~ pravements and na encroachments on said premises by buildings; structures or:other itnp'rovements , ~ situated an adjoining premises. This survey .meets the "Minimum Stgndord Retail Requirements for • ALFA/AGSM Land Title Surveys" as jointly adopted by.A1.TA and':ACSM.in 1992. i. ' R - 7323,36 a \ ~ ~ ..ti , ~ i / ~ r' ~ • • N 17'28 OS E ~ N \ / Ch. - 112.98 ~ \,,f / • \ ~ ~ i . 1r ~ ~ Professional Surveyor No $808 ~j111{iIP ~F• !1y • THOMAS \ ~ • SCAL£.• 1" = 5D' o - IRAN t~IN , ~ ~ ~ • ~ ~ .~iBBALDS o \ / ; OC7"r?B~'R JO;. 1987 ~ `o~~F 5908 o aw ~ .l . ~ s c~ sT.~ ~ i1''1 • ~ _ S J X1.1 .Blanket` ' Easem~n t ~ ' ' ,O,R. 084 ~ / 54 D 20 9. zr l ON AL`.51~~i~i • ~ 50' 0 5 ~ 1104 ' .~5 • ' N , . • . . W ' GRAPHIC' SCACE' . . , . • jlN• f££T}. • . ~ 6 w.,,' . • 8Q, p0 ' . BASIS BASIS OF BEARINGS.: The bearings shown on NOTE ' Su.bjoct property lies within Zone "X" (areas outside 500 year `flbodplail as' shown on Federpl thi; this plat ate',based on-.the same meridian Emergency Management Agencys Flaad.InsuranceRts;1~Iargh,io and Ui~jncorpotrted.`Ared,s) as the westerly, line, of Lots 6 & .7 of the Cornm~anity Panel Number 39049C0107 G; Panel 4;07 v1 X87, effective datd August 2,: 199: . recorded plat of "METROCtNTER" of record in l rR C in Plat Book.-5.5, Pages. 8.&.9, Recorder's N T Off Office, Fron.klin County; Ohio, r Po 5'7 Pg. 36 L, & 8. CROUP INC. Q ~Pl;'fJJ~19T13I(11pV~Z~lt-70~Jf] d~u DEMO CODED NOTES AA~~ .~F DOOR SCHEDULE DEMOLITION NOTES REMOVE EXISTING WALL AND PATCH CEILING tJ GRID TO MATCH EXISTING PONE DOOR FRAME REMARKS ILSANDAs L NOTES 1. PERFORM DEMOLITION AS INDICATED ON PLANS AND DETA ENERAL ELECTRICA p G 1 SIZE Z REQUIRED FOR THE COMPLETION OF THE PROJECT AS INDICATED. Q J J F- g Q a w 2, PROVIDE ADEQUATE TEMPOR4RY SUPPORT FOR WORK BEING CUTAND 1, ALL ELECTRICAL WORK SHALL CONFORM TO THE CURRENT ~ ~ ~ ~ w w PATCHED TO PREVENT FAILURE. DO NOT ENDANGER OTHER WORK. PROVIDE NATIONAL ELECTRIC CODE AND THE OHIO BUILDING CODE. p r F.. ~ 4 Q p ADEQUATE PROTECTION OF OTHER WORK DURING CUTTING AND PATCHING TO A ~ ~ ~ = PREVENT DAMAGE. CUT WORK TO BE PERFORMED BY METHODS LEAST LIKELY L NEW WIRING SHALL BE PROVIDED IN CONDUIT, ALL WIRING ABOVE THK 2. AL L NUM RATED. ALL CONDUCTORS SHALL BE D . STND, RELOCATED 1 SEE ELEVATION A TO DAMAGE WORK TO BE RETAINED ANDIOR WORKADJOINING, THE CEILING SHALL BE P E 500 EXISTING 1314 BL G GENERAL NOTES I _ s~ t ~f' ~ COPPER, MINIMUM SIZE #12 AWG FOR BRANCH CIRCUITS; #14 AWG FOR 3, DO NOT CUT AND PATCH WORK WHICH WILL IMPAIR THE STRUCTURE'S LOAD CONTROL CIRCUITS, CONDUCTORS FOR THE LIGHT FIXTURE CARRYING CAPACITY OR REDUCE THE LOAD! DEFLECTION RATIO, CONNECTIONS SHALL BE THW, THHN, OR XHHW, 1, ALL DIMENSIONS SHOWN ON THE DRAWINGS ARE FROM INSIDE FACE OF STUD TO INSIDE FACE OF STUD, UNLESS NOTED OTHERWISE. v ~ o o ~ 4, PATCH AND REPAIR ALL REMAININGWALL, FLOOR AND CEILING WITH ro~ooo 0 3. ELECTRICAL CONTRACTOR SHALL INSTALL SERVICE TO ALL NEW APPROPRIATE MATERIALS COMPATIBLE WITH EXISTING SUBSTRATES AND NEW 2 CONTRACTORS SHALL VERIFYANDCHECKALLDIMENSIONSAND.. ~ ~ N N ~ EQUIPMENT ONLY FROM APPROVED SHOP DRAWINGS OF SUCH FINISH MATERIALS. EQUIPMENT, WHICH SHOWS AND DIMENSIONS ALL CONNECTION POINTS. HARDWARE SCH E,DU LE CONDITIONS ON THE JOB PRIOR TO COMMENCING WORK, AND SHALL ° p ~ m REPORTANY DISCREPANCIES TO THE ARCHITECT. 3 ~ ~ ~ P DRAWINGS SHOWING ALL NEW PANELS, CIRCUITING, 5, PATCH WITH SEAMS WHICH ARE DURABLE AND AS INVISIBLE AS POSSIBLE, SUBMIT SHO TC. TO ARCHITECT FOR APPROVAL, COMPLY WITH SPECIFIED TOLERANCES FOR THE TYPE OF WORK BEING DONE, BREAKERS, E SET 1 RESTORE EXPOSED FINISHES OF PATCHED AREAS AND WHERE NECESSARY, 3, UNFINISHED INTERIOR TENANT SEPARATION WALLS SHALL BE INSULATED;~~-~~ ~ ~ ~ BLE SIZES ARE BASED ON ALUMINUM, ALL OTHER 6 BUTTS AND FINISHED TO MATCH THE SELECTED TENANT FINISHES, U.N.O. ~ 4. SERVICE ENTRANCE CA EXTEND NEW FINISH ONTO ADJOINING RETAINED WORK IN A MANNER WHICH ON COPPER. ALUMINUM WIRE MAY BE SUBSTITUTED 2 STOP WIRE SIZES ARE BASED TRANCE LOCK WILL ELIMINATE EVIDENCE OF PATCHING. 4. DOOR FRAME ROUGH OPENING HEIGHT SHALL BE 1'-1"FROM THE SLAB R TRANSFORMER TO MAIN SWITCHGEAR IF APPROVED BY 1 EN FOR COPPER FROM 2 CLOSERS 6, ANY EQUIPMENT, FIXTURES OR ANY OTHER ITEMS NOT SPECIFICALLY SHOWN TO THE METAL STUD HEADEAFOR T-0"INTERIOR DOORS, U.N.O, + THE LOCAL POWER COMPANY. FEEDER WIRE AND CONDUIT FROM IZED IN WITH DASHED LINES DESCRIBED HEREIN "TO BE REMOVED"REMAIN AND ARE 5. ALL LOCKS SHALL BE OF A TYPE WHICH WILL NOT REQUIRE THE U~F A ' SWITCHGEAR TO PANELS MAY BE CHANGED TO ALUMINUM IF AES TO BE PROTECTED FROM DAMAGE, NOTIFY OWNER'S REPRESENTATIVE OF ANY KEY OR SIMILAR DEVICE TO PERMIT EGRESS, THE LATCHES OR B~LT~ ACCORDANCE WITH N,E~C. ITEMS WHICH MAY {NTERFERE WITH THE PROGRESS OF THE DEMOLITION WORK 1 ~ SHALL BE RETRACTED FROM THE KEEPERS BY THE USE OF A LE!~R, WHICF~° ANY PERSON CAN OPERATE WITH REASONABLE EASE AND WITH T TE CIRCUIT WIRED BEFORE DISTURBING SAID ITEMS. 5. SWITCHGEAR SHALL BE WIRED TO PROVIDE A SEPARA , AHEAD OF THE MAIN, TO SERVICE ALL EXIT LIGHTS, OR BATTERY PACK 7, UNLESS NOTED OTHERWISE, ALL MATERIAL TO BE REMOVED SHALL BE ii INSTRUCTION. t~ -I-~ TYPE EXVT LIGHTS AND SHALL BE WIRED INTO A POWER CIRCUIT AHEAD OF PROPERLY DISPOSED OF, OR SALVAGED OFF-SITE, BY THE CONTRACTOR, 6. REPLACE EXISTING KNOB TYPE HARDWARE W{TH A.D.A. APPROVED LEVER i i TYPE HARDWARE TO MATCH THE BUILDING STANDARD FINISH. ~ ~ ANY SWITCHING. FINISH SPECIFICATIONS 8. REMOVE ALL EXISTING CARPET AND UCT WALL BASE. THROUGHOUT. , d 6. DIRECT BURIAL PVC CONDUIT MAY BE SUBSTITUTED FOR UNDERSLAB WORK INSTALLED ACCORDINGLY TO N.E.C. AND APPROVED BY LOCAL Ke IteiTl Specification IF Y _ AUTHORITIES HAVING JURISDICTION. (SWEEP ELBOWS PENETRATINGTHE -1 CARPET COMMERCIAL GAADECARPET- STYLE AND COLOR TBD - EEL, NO PVC CONDUIT OF ANY TYPE SHALL BE INSTALLED C SLAB SHALL BE ST PENETRATING THE SLAB OR ABOVE SLAB. „ h ~w VCT-1 VINYL COMPOSITION TILE ARMSTRONG • STANDARD EXCELON IMPERIALTEXTURE #51899 COOLWHITE ~ Its IT INSTALLED AS el I IO 7, WIRING RUN THRU MASONRY SHALL BE IN CONDU , INTERIOR FIMSH REQUIREMENTS d2CnOlItlOn plan WALLTYPES LEGEND ~ C~ EXISTING PARTITION WALL TO REMAIN U THE MASONRY IS LAID UP. WIRING MAY BE RUN IN THE WALL B-1 BASE JOHNSONITE, 4"COVE COLOR TBD 118-1-0 INULATIONSPACE AND MAY BE ROMEXTYPE IFAPPROVED BYCODE. - DE PSTAR SLATE INTERIOR FINISH OF WALLS AND CEILINGS SHALL HAVE AFLAME-SPREAD AND SMOKE TYPE, PL-1 PLASTIC LAMINATE WIL50NART 1818 35 E UNDERGROUND WIRING SHALL BE DIRECT BURIAL DEVELOPED RATING NOT GREATER THAT THAT LISTED BELOW AS TESTED IN C....J EXISTING PARTITION WALLTO BE REMOUEO ACCORDANCE WITH ASTM E 84. THE CLASSIFICATIONS OFINTERIOR FINISHES LECTRICAL CONTRACTOR SHALL TESTALL WIRING FOR P-1 PAINT (WALLS & SOFFITS) SHERWIN WILLIAMS EGGSHELL FINISH- COLOR TBD CORRESPOND TO THE FOLLOWING: e. E • CONTINUITY AND GROUNDS BEFORE FIXTURE INSTALLATION, CLASS A'. FLAME SPREAD 0-25; SMOKE DEVELOPED D-450 g ALL ELECTRIC PANELS EXPOSED TO VIEW SHALL HAVE THE COVERS AND MATCH EXISTING BUILDING STANDARD CLASS & FLAME SPREAD 26-15; SMOKE DEVELOPED 0-450 DOORS PAINTED WITH SEMI-GLOSS PAINT TO MATCH ADJACENT WALLS, CLG 1 CEILING CLASS C; FLAME SPREAD 76.200; SMOKE DEVELOPED 0-450 NEW WORK PLAN CODED NOTES AS SPECIFIED UNDER THE PAINTING SPECIFICATIONS, DOORS, HARDWARE AND BLINDS ARE BUILDING STANDARD AND LEVER TYPE DOOR HANDLES PLASTIC LAMINATE CABINETS- BUILT MORE #7924-01 WILSONART TYPE OF SPACE MIN CLASS REQ'D 509 508 507 506 1? PATCH EXISTING WALLS TO MATCH EXISTING ~ ~ 10. ALL LIGHT FIXTURES SHALL BE AS NOTED ON THE FIXTURE SCHEDULE AND CUT SHEETS SHALL BE SUBMITTED TO THE ARCHITECT FOR VERTICAL EXITS AND EXIT PASSAGEWAYS A OFFICE OFFICE OFFICE OFFICE REVIEW AND APPflOVAI PRIOR TO ORDERING THE FIXTURES. EXIT ACCESS CORRIDORS AND OTHER EXITWAYS B C-1, 8-1, P-1 C-1, B-1, P-1 C-1, B-1, P-1 G1, B-1, P-1 ' ~ ~ ROOMS AND ENCLOSED SPACES C ~ ~ ~ w ~ O 11. ALL DUPLEX OUTLETS AND COMMUNICATION JUNCTION BOXES SHALL AT 16"ABOVE THE FINISH FLOOR UNLESS NOTED OTHERWISE. PANEL 200 AMP 10,OD0 A.LC, TRIM ? FLUSH A SURFACE R BASED SUCH AS CARPET, SHALL CONFORM TO BE ¦ WI GROUND BUS FLOOR FINISHES THAT ARE FIBE OUTLETS SHALL NOT BE LOCATED fN THE SAME STUD SPACE ON (EXISTING 1201208 VOLT, 3 4 W, 60 Hz W 'SOLID NEUTRAL CLASSIFICATIONS ASTESTED INACCORDANCE WITH NFPA 253. THE CLASSIFICATIONS EXIST. \ ~ ` ~ ~ ~ d' E IN NEWLY C: ~ ! OPPOSITE SIDES OF A COMMON WALL ALL SWITCH S FED FROM; Transformer LO ¦ W(MAIN CIRCUIT BREAKER ARE AS FOLLOWS: CLASS I, 0.45 WATTS~CM2 OA CREATED; CLASS LI, 022 WATTSICM2 QR WALLS SHALL BE LOCATED AT 48"ABOVE THE FINISH 5LV2A K OUT" ? WI MAIN LUGS ONLY 225A Y LINOLEUM TERRAZZO AND CONSTRUCTED ~ LOC GREATER. FINISHED FLOOR MATERIALS OF WOOD, VIN L, 510 ~ ~ n ~T~ 0 FLOOR UNLESS NOTED OTHERWISE, COVERINGS ARE EXEMPT FROM THESE REQUIREMENTS. W.S. TR,A, LOAD C# C#~ LOAD TA.A. W.S. OTHER RESILIENT FLOOR CLOSET w W W ~ ~ ~ ~ 1 . ELECTRICAL CONTRACTOR SHALL COORDINATE TELEPHONE 12 20 EXISTING ELECTRIC 1 2 EXISTING ELECTRIC 20 12 MIN CLASS AEQ'D ~ - 2 1YPE OF SPACE 511 512 ~ ~ C-1, B-1, P-1 v ` SYSTEM INSTALLATION AT OUTLET LOCATIONS SHOWN ON THE N ELECTRIC 3 4 EXISTING ELECTRIC 20 12 A UCBR B K, P-1 BREAK 504 505 ~ I G ; ~ j, _ C ` TALLED 12 20 EXISTI G PLANS, TENANT'S VOICE AND DATA SYSTEM SHALL BE INS I T NG ELECTRIC 5 6 EXISTING ELECTRIC 20 12 12 20 EX S I VERTICAL EXITS, EXIT PASSAGEWAYS AND II C-1, B-1, P-1 OFFICE OFFICE 112 STIR ~ ~ ~ j ~ PER THE OWNER S DIRECTIVE. 12 20 EXISTING ELECTRIC 7 8 EXISTING ELECTRIC 20 12 EXIT ACCESS CORRIDORS U _ _ - - _ C•1, B•1, P•1 C-1, B-1, P-1 1 ~ i ~~fTpa pE I ~JE ~ ~I~~, p, ~~f~~~pR VEST ~ ~ 12 20 EXISTING ELECTRIC 9 10 EXISTING ELECTRIC 20 12 DOC FF-1 "PILL TEST" ALL OTHER AREAS 12 20 EXISTING ELECTRIC 11 12 EXIST. I~[JE PGI~ A~1p Rl~r:+ T 1 V~ 5 0 500 502 ~ VEST AO~E TI~G, ,i ! , 12 20 NEWFURNITURE 13 14 SUBPANEL 60 8 EN~ UCT-11 B-1, P-1 EXIST, 1 I~~' G PIJ~ EGT~EFE~p; I ' 12 20 NEW FURNITURE 15 16 NEW DISPOSAL 20 12 C-1 8.1 P•1 ,y ~EV~ ~U~BI EpU~ pF QIRjp~ I~ [ ~ D ; , ~ i' ~ CJ S 12 20 NEW FURNITURE 17 18 B ~5a~ 503 ` SEEUPEsp~ 11~° 6ppP ' ~ I , ~ I 12 20 NEW COPIER 19 20 NEW DED. RECEPTACLE 20 12 NEW DED. RECEPTACLE 20 12 NOTE: Q ~ , ~ HALL ~ CONFERENCE Fj~ ~ 1 12 20 EXISTING ELECTRIC 21 22 - EXISTING ELECTRIC 20 12 ~ C-1, B-1, P-1, ~ j . 12 20 EXISTING ELECTRIC 23 24 ALL LIGHTS ARE TO REMAIN AS EXISTING. NO NEW LIGHTING CIRCUITS REQUIRED; o u~i CLG-1 1 ~ i w ° ~ ~ 12 20 EXISTING ELECTRIC 25 26 NEW CFI RECEPTACLES 20 12 INSTALL LIGHT SENSOR IN CONFERENCE ROOM # 503 AND BREAK ROOM #611. R a - u~ [JITA ~I~ ~ ~ ~ ~ 12 20 EXISTING ELECTRIC 27 28 EXISTING ELECTRIC 2D 12 513 ~ ISTI~G)~8 TO ~ ~ ~ 12 20 NEW FURNITURE 29 30 EXISTING ELECTRIC 2D 12 CLOSET ~pEP&D~I~; ' 31 32 REFRIGERATOR 20 12 NOTE: ALL LIGHTING ON EXISTING CIRCUIT, NIGHT LIGHTS 12 20 NEW FURNITURE T N ELECTRIC 20 12 AND EXIT LIGHTS ON EXISTING EMERGENCY CIRCUIT C-1, B-1, P-1 p~ GT , 12 20 NEW FURNITURE 33 34 EXIS I G STp E~' FIE~O 12 20 EXISTING ELECTRIC 35 36 NEW RECEPTACLES 20 12 VEPI~ip~ I~ 12 20 EXISTING ELECTRIC 37 38 NEW REFRIGERATOR 20 12 ~p~~ ~ SPACE 39 40 IT ROOM 20 12 N 12 20 EXISTING ELECTRIC 41 42 DISHWASHER PLUMBING STACK DIAGRAM ~ ~ ELE TRICAL SYMBOLS LEGEND C LOAD 50.2 KW,139 AMPS n DUPLEX RECEPTACLE neYY f~fth fI00r YVOrk plan NOTE: SAW-CUT EXISTING CONCRETE N,TS. '~""~4P"'•' ~ ~ SLAB AS REQUIRED FOR NEW ~ 1 ~$"=1'-O° PLUMBING LINE, PREPARE FLOOR FOR a~~nk.,.. `u ~ QUAD RECEPTACLE NEW FLOOR FINISH INSTALLATION. ~ ~ ~ ~ FILLER AS NEEDEDI PLUMBING FIXTURE SCHEDULE ~ 0 ~ C~ 48W30 24W15 39W30 36Wl15 S-1 ELKAY (ORAPPROVED EQUAL) ~Y~ r , r--, I I STAINLESSSTEELSINK,ELKAYMODELLR3122SINGLECOMPARTMENT, ~ D ~ 0 SELF RIMMING,18 GAUGE, TYPE 304 STAINLESS STEEL, 31"x22" OVERALL I I ~~r::: I I ::N..:...:....... ? ~ SIZE, 28"x16"xl 112" DEEP BOWL SIZE, FURNISH WITH 4 HOLES, ELKAY ~ CO I FILLERASNEEDED 1 r ~ ' . ~ ~ ° ' ~ MODEL LK-2442BH DUAL HANDLE FAUCET, EXPOSED MIXING BODY, ~ ~`.V ~ HI-ARC FIXED GOOSENECK SPOUT, AERATOR AND WING HANDLES, ~ , I i I I ELKAY MODEL LK-35 BASKET STRAINER,1112° TAIL PIECE AND 1112" ~ °r ~ M.W. BY TENANT CAST BRASS P-TRAP. PROVIDE W(CHROME PLATED KEY OPERATED I I STOPS AND CHROME PLATED SUPPLY RISERS. RA Proj. Na.: 08120.050 480 V, FUSIBLE SWITCH 60 AMP, I I I I ;r ~ S.S. SINK WITH GARBAGE DISPOSAL I I I I I ~ ~ REF, poser In-Sink-Erator Model No. 333 r Drawn by: MK 0 0 Dis ~r~;~,-_~:::.. ~ I I BY (~HP,120V11PH) ~~~CheckedBy, CRH . . r i I I I I I Date: 4/9(2008 BY I I _J ' TENANT ~ Revisions ~ EXISTING EXISTING ~-~--PI' PANEL PANEL , I II 5LV2A 5LV2B - Q AREA OF WORK 2000 AMP 480 V, BUS DUCT i i I ~ - , 2A-38 ' I I I ;EXISTING ; - ; ~,-36 2A-42: I I 2A 36 a eva ion I I; I T-41V ~ ~ ~ n A 48836 39SB36 ~ ~I I I I I I 130KVA ~ ~ I I I i_~ ~ I I I DED, 17" 11° 48°G.F.I. ~ L__J ~i I I ~ ~ I QED. ~ i I - / ~--E4-#4, 1-#8 2A-40 ~ GROUND, ~ 1/4" C) it TOTAL DEMAND z2KW 60 AMPS i r I ~ - 0 o ~ i M ~ ~ 3- #8 & 1- #10 GND IN I" 4- #3 & I- #8 GND IN 1 1/4 _ ~ CONDUIT L'u vuuii existing riser diagram nts fl Al m0l NEW TEMPERED GLASS INSERTS IN EXISTING DOORS ?ation B fifth floor key plan new power plan elevation B 318"-1-0" . n.t.s. 1(8"-11-0"