Loading...
08200197 Permit File CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 C E R T I F I C A T E OF O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 6/20/08 Parcel Number . . . 273-001344 Property Address . . . 555 METRO PL N FR DUBLIN OH 43017 Subdivision Name . . . Legal Description . . . 555 METRO PL N METROCENTER 5.635.ACRES LOT 5 Property Zoning . . . . PLANNED UNIT DEVELOPMENT Owner . . . . . . . . . 555 METRO LLC Contractor . . . . . . CHAMPION SERVICES, LLC 614 335-2020 Application number 08-00200197 000 000 Description of Work COM BUILDING ALTERATION Construction type . 1B - PROTECTED/NONCOMB Occupancy type . . . . BUSINESS Flood Zone . . . . . . Special conditions . . MAHINDRA SUITE 390 Approved . . . . . . . ~/4ei d' g fficial VOID UNLESS SIGNED BY B DING OFFICIAL CITY OF DUBLIN Division of Building Standards • 5800 Shier Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 COMMERCIAL INSPECTION SIGN-OFF Project Name: MAHINDRA Use Group: B Construction Type: 1 B Application No: 08-200197 Project Address: 555 METRO PL. N. #390 General Contractor: CHAMPION SERVICES Building Code: 07 OBC f _ - IMF Sewer Tap **Rough Sprinkler Footing Electric Service Foundation Steel Framing rye Footing Steel Grounding Shaft Walls Foundation Insulation Piers Fireplace Waterproofing Curb, Walk & Approach Electrical Underground Above Ceiling Electric ~j Plumbing Underground Above Ceiling HVAC 5-((3/05- f} ~L **Sprinkler Underground **Above Ceiling Sprinkler q ~ Pre-Slab Above Ceiling Structural Diamonds Final Electric G3, Structural Steel Final Plumbing Fireproofing Final HVAC 27, 0& 1W ~f Masonry Wall Grout Final Gas Piping **Fire Alarm Rough _ **Fire Prevention G O~j Rough Electric Zoning Final Rough Plumbing ,a Engineering Final Rough HVAC Life Safety & /?.a Rough Gas Piping Occupancy ~Wo 2vcC- "Please call Washington Township Fire Department at 652-3920 to schedule these inspections. DATE INSPECTION COMMENTS APPROVAL INSPECTOR TYPE CODE 3c c - cr. WRY- f4CVE0 - CC H ~R trr'- 7" 4 (3 0- L e-- I to -VC16-d v2n C I L Gr' , (O 7 C) iz- Z!4Z to S- Fr" IVN a- 1415 1 I Building Standards - Review Services Commercial Building Permit Application 5800 Shier Rings Road Dublin OH 43016 Phone (614) 410-4670 Crfx OF DUBLIN- Application Number Received Date StanW PROJECT INFORMATION ? New Building ? Building Addition Alteration/Fitup ? Accessory ? Change of Occupancy Project Name Project Size 7,909 NFAA*W%ZA _Square Feet Project Address Estimated $ Cost ) ~C of Construction Tax Parcel OBC Cons ction Type(s) OBC Use Group(s) Number " © Vk PROPERTY OWNER Corporate/Company Name (if applicable) -LAIC Owner (person's name) P 141 At - Title 00 City/State/Zip Address © U 'Tt Telephone Fax O Email t 6 i~ TENANT (if applicable) Company Name Contact Name Title Address City/State/Zip Telephone Fax Email ARCHITECT Design Professional's Name Contact Name Ohio Registration Number 2 C~ Address tL City/State/Zip Telephone Z , '~~Fax 1 Email CIVIL ENGINEER (if applicable) Design Professional's Name Company Name Ohio Registration Number Address City/State/Zip Telephone Fax Email GENERAL CONTRACTOR Company Name ok"4 Dublin Registration Number Contact Name Title Address City/State/Zip Telephone Fax Email PROJECT REPRESENTATIVE / CONTACT (original signature required) I acknowledge and make this application as, or on behalf of, the owner and further assert that I am the agent / representative to be contacted concernin matters relating to this application. ` Sign (print name) Q~IN ~/y""" fe Date 11-4946 Company C',62N0y• Z6A/41,0ie Phone -77Z`" lCOO Email o&vxoe4 Commercial Building Permit Application Page 1 of 3 BLD-201 01/14/08 Commercial Building Permit Application Application Number PROJECT INFORMATION l ( Completed by Design Professional) Project Address PROJECT SCOPE & DESCRIPTION TYPE OF WORK ? New Building ? Accessory Structure ? Addition: Fire Wall ? Yes ? No ? Change of Use: ? Entire Structure ? Partial ~CAIteration: Article 34 LJ Yes ? No ? Change of Occupancy: ? Entire Structure ? Partial Previous Use(s): OBC Use Group(s): NEW CONSTRUCTION ANALYSIS (complete for Additions and New Buildings/Structures) Occupancy Description: OBC Use Group(s): \ Mixed Use:; No Yes - if Yes: ? Separated ? Non-Separated OBC Construction Type: IFj Stories Above Grade: Building Height: Basement: ?Yes Xio Fire Resistive Construction Rating Fire Test Design Num1pers Exterior Walls Fire Walls Hr Floor/Ceiling Z Hr Columns/Bearing Wall Z Hr Exit Enclosures Z. Hr Shafts Hr Corridors Hr Tenant Separation Hr Floor Information Floor Area (s.f.) Occupant Load/Floor Egress Capacity/Floor Number of Exits Basement 1" Floor 2nd Floor 3td Floor 1i 4'h Floor & above Allowable Maximum Floor Area (first floor footprint): ®Q Square Feet This value includes: Street frontage increase? ?Yes '"o Increase for sprinklers? ?Yes o Commercial Building Permit Application Page 2 of 3 BLD-201 01/14/08 wr - rwo arnrv~~,+~wr+wawurwrr~m ' Application Number Commercial Building Permit Application PROJECT INFORMATION ( Project Address Continued) Fire Related Items Horizontal Exits es ? No Smoke control/Removal system ? Yes No Limited Sprinkler System VYes ? No Unlimited Area Building ?Yes No Full Automatic Sprinkler System ? Yes [ CNo Manual Fire Alarm ? Yes X No Standpipe System Fes ? No Auto Fire Alarm XYes ? No EXISTING STRUCTURE ANALYSLS (complete for Additions and Alteration/Fitups) Occupancy Description: © 0161 OBC Use Group(s): Mixed Use: Y-No ? Yes - if Yes: ? Separated ? Non-Separated OBC Construction Type: 116 Number of Stories Above Grade : Bldg Height: t Basement: ?Yes No Floor Information Floor Area (s.f.) Occupant, LoadfFFloor EV= Capacity/Floor Number of Exits Basement 1 S` Floor t` 2nd Floor q'm Z Z 3`d Floor d~f - b Z 4`'' Floor & above Allowable Maximum Floor Area (first floor footprint): Square Feet This value includes: Street frontage increase? ?Yes IkNo increase for sprinklers? ?Yes o Fire Related Items Horizontal Exits Yes ? No Smoke control/Removal system ?Yes VNo Limited Sprinkler System es ? No Unlimited Area Building ?Yes KNo Full Automatic Sprinkler System ? Yes K No Manual Fire Alarm ? Yes )(No Standpipe System Yes I 1 No Auto Fire Alarm AYes ? No I ,,ArA , the Design Professional, have read and understand the contents of this application. The information contained in this application, attached exhibits, and other submitted information is complete and in all respects true and correct, to the best of my knowledge and belief. p Signature of Design Pro ~~~~..Date--? Contact the City of Dublin - Commercial Building Permits Building Standards - inprocessing and outprocessing 614-410-4670 Fax 614-761-6566 jbrock@dublin.oh.us Review Services - plan review activities and tracking 614-410-4620 Fax 614-718-4346 ssnyder@dublin.oh.us Commercial Building Permit Application Page 3 of 3 BLD-201 01/14/08 ' CITY OF DUBLIN Building Standards • 5800 Shier Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 nWALK-THROUGH ELIGIBILITY EVALUATION FORM Project Name: - o~ Project Address: t~ C LJ~1~G Applicant: Phone:!Q2, f~~ Author of Drawings (in attendance): Phone: -7Q 7,- 1 W 0 General Contractor (required): Cf/AM/p/C~/y S?/.S L.Yl>• Contractor Registration Number: Project Square Footage: Circle the appropriate category/categories in each box and put the corresponding point value in the equation at the bottom of the page. A B C D Square Footage Use Group(s) Type of Construction Plan Originator 0 to 1000 ..................1.0 Al ...........................3.0 I~..........................3.0 Ohio Architect, 1001 to 2000 .............1. A2................. 3.0(B........................... 2.5 Ohio Engineer, 2001 to 3000 A3 ...........................1.8 Certified Designer or a 3001 to 4000 .............2.5 A4...........................1.6 IIA........................... 2.5 combination of 4001 to 5000 .............3.0 5...........................1.0 116........................... 1.0 above ..1.0 B .............................1.0 Projects over 3,000 sq. ft. 1.8 IIIA ..........................2.5 Non-professional........ 3.0 are not considered without F1 & F2 ....................2.5 IIIB.......................... 1.3 CBO permission. H NIP Author of the drawings "Rated corridor if 30 or 1 1,2,3 ......................3.0 IV.................... 1.2 must be a certified more occupants. M ............................1.8 professional if the project R ..............................1.5 VA............. 2.5 requires technical analysis S1 ...........................1.4 VB............. 2.5 of safety or sanitation. S2 ............................1.2 U ............................1.0 E F G H Nature of Work Permits Required Number of Floors Number of Drawings (Add all permits required (Involved in the review) (Excluding cover sheet) Alteration ..................1.0 Building.................1. 1 ...........................1.0 1 1.0 Demolition & Zoning Compliance.... 0 2 .............................2.0 5-8 .........................2.0 Build Out .................1.2 HVAC minoNexisting... - 3........................3.0 New Building HVAC new system(s).. Permission required from 14-20 ......................4.5 (<120 sq. ft.) .............1.2 Electrical (minor)..... ..1.0 CBO for any more floors Addition Electrical (new equip).. .0 involved. (<1,000 sq. fl ............1.0 Change of Permit Occupancy ......:.........3.0 Point Total.......... Additions > 1, 000 sq. It. and new buildings > 120 sq. ft. are ineligible- -2- + 1 + ~j l3 7 A B C D E F G H TOTAL • The sum of the above calculation may not exceed 14 for Walk-Through consideration. • The approved Record of Action or any required Zoning hearing is required at this review. • The Plans Examiners will table any examination that will take more than 25 minutes. Fax this completed form, Building Permit Application and Zoning Compliance form to Building Standards 614-761-6566. T:\OFFICE\WP\DOCS\DOC\Excel\2006 walkthrough CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 APPLICATION FOR HVAC PERMIT Date 0 Application No. Job Address M Parcel No. Subdivision c L Z_ Lot No. \ ~Y C~ Owner Name "1` Telephone 4 0~ QT~S Contractor Name (9:ft\ e ' A Telephone Contractor Address U Ol C~3 Dublin Registration No. Residential: Sq. Ft. $60.00 Minimum plus $30.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. $60.00 REPLACEMENT UNITS GAS ELECTRIC. (Minimum fee only) Commercial: New/Addition Sq. Ft. Alteration New/Addition: $70.00 Minimum plus $30.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Alteration: $70.00 Minimum plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. 3% State of Ohio Surcharge (commercial only) Total $ JOB DESCRIPTION This permit is granted on the express condition that the said work s II in II s s nform to the ordinances of the City of Dublin and all the laws of the State regulating construction, installation, repair nd alt atio , a may be revoked at any time upon violation of any provisions of said laws. Signature of licensed contractor or homeowner Division of Building Standards Q CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200197 Date 5/05/08 Revision number . . . . . . . 1 Property Address . . . . . . 555 METRO PL N Parcel Number: 273-001344 Alternate Address: METRO CENTER Tenant nbr, name . . . . . . 390 MAHINDRA #390 Application type description COM BUILDING ALTERATION Property owner . . . . . . . PARKVIEW LIMITED P/S Contractor . . . . . . . . . CHAMPION SERVICES, LLC Structure Information 000 000 Construction Type . . . . . 1B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . COM HEATING, VENTILATING, A.C. Additional desc . . Permit Fee . . . . 130.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/01/08 Qty Unit Charge Per Extension BASE FEE 70.00 3.00 20.0000 THOU COM HVAC ALT 60.00 Special Notes and Comments IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA Other Fees . . . . . . . . . SURCHARGE FEE - HVAC 3.90 Fee summary Charged Paid Credited Due Permit Fee Total 130.00 .00 .00 130.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 3.90 .00 .00 3.90 Grand Total 133.90 .00 .00 133.90 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 462-3865 (Franklin County) Application No. 0 y • Ado 1 - -I Date ? New /Remodel ? Residential ? Commercial APPLICATION FOR PLUMBING PERMIT The undersigned hereby applies for a permit to do plumbing and an inspection of same at the following location in accord with Chapter 4101:2-51 of the Ohio Administrative Code, and all regulations of the Franklin County Board of Health. Job Address Parcel No. Subdivision/Project Name Lot No. Owner's Name Telephone r-_--inaAZ-et~ Contractor's Name Telephone 'W7 7 ~lfJ Number Contractor's Address 4) 7 Dub l Does the sewer discharge into an individual sewage disposal syste or s How far distant from any dwelling, well or cistern is the sewage tank? What is the size of the main drain? Of what materials do the vent pipes consist? Of what material does the house drain consist? *INDICATE NAME OF CERTIFIED BACKFLOW TESTER This form must be properly filled out and returned to the office of the City of Dublin at least four days prior to the date of the FIRST INSPECTION, accompanied by a fee calculated upon the following basis: WATER TANK REPLACEMENT FEE $35.00 RESIDENTIAL COMMERCIAL Application for permit & first fixture $50.00 Application for permit & first fixture $60.00 Number of remaining fixtures X $10.00 = $ Number of remaining fixtures X $12.00 = Total Inspection Fee $ Total Inspection Fee $ Re-inspection fee (based upon disapproved Inspection and collected by the Franklin County Board of Health ONLY) $45.00 Qty. Qty. Qty. Air Admittance Valve Garbage Disposal Showers *Backflow Preventers Gas Water Heater Sterilizers Bath Tubs Electric Water Heater Sump Pump Bed Pan Washers Interceptor Trap Primer Bidet Kitchen Sink Urinal Chemical Sinks Laundry Trays Wash Fountain Dental Cuspidors Lavatories Washing Machine Dilution Sum Mop Sinks Water Closets Dish Washers Outside Faucets Water Lines Drinking Fountain Roof Drains Water Storage Tank Floor Drains Rough-in Openings for Future Other Garage Catch Basin Sewage Ejectors GRAND TOTAL r Division of Building Standards CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200197 Date 4/22/08 Revision number . . . . . . . 1 Property Address . . . . . . 555 METRO PL N Parcel Number: 273-001344 Alternate Address: METRO CENTER Tenant nbr, name . . . . . . 390 MAHINDRA #390 Application type description COM BUILDING ALTERATION Property owner . . . . . . . PARKVIEW LIMITED P/S Contractor . . . . . . . . . CHAMPION SERVICES, LLC Structure Information 000 000 Construction Type . . . . . 1B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . PLUMBING PERMIT Additional desc . . Permit Fee . . . . 60.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/15/11 Qty Unit Charge Per Extension BASE FEE 60.00 Special Notes and Comments IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA Fee summary Charged Paid Credited Due Permit Fee Total 60.00 .00 .00 60.00 Plan Check Total .00 .00 .00 .00 Grand Total 60.00 .00 .00 60.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. _ _ _ _ rrrrr 04/22/08 13:29 FAX 6144623851 COUNTY-BOARD-OF-HEALTH 2001 P.2 - - - - - - - - _ T0: 4623851 APR-21200 07 151A FROM: CLASSIC PLUMBING INC 6146773110 r Franklin County Board of Health • PLUMBING REVIEW 0 TRANSMITTAL Number of Fixtures: Plan Review Fee Schedule 2 S Amount Due: 1 - 5 Fixtures . $ 25.00 6 - 20 Fixtures $ 35.00 21- 40 Fixtures $ 65.00 41 or more Fixtures $100.00 THIS Ja#WED SEJQKAggL Date: 2 MUST BE ON THE JOB SITE. Job Name: h 1lip 111,101, 111 " l( ANY ALTERATIONS TO 'I E{E GL FS TEM MUST BE 55-5 1 - Address: REVISED PRIOR TO INSPECTION. City: ~wb Signature: Plans Submitted by. Address: tD Phone M. City & Zip ~ APPROVED Paid By: G°--_ p~ DISAPPR VIED Sri"NG- Check Inspector: z z Copy To. Date: Columbus, OH 43215 Board of Health ? 280 East Broad Street fa Franklin County (614) 462-3160 Phone ? (614) 462-3651 Item 6. OBC 1 103.1 Where required. Building and structures, temporary or permanent, including their associated sites and facilities, shall be accessible to persons with physical disabilities. OBC 1 103.2.1 Specific requirements. Accessibility is required in building and facilities, or portions thereof, to the extent indicated in ADAAG Section 4.1 and this chapter. The start of construction indicates acceptance of all the conditions listed above. This review does not preclude the necessity to conform to provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rest with the registered design professional, the tenant and the owner. Plan Approval will be valid only upon receipt by the City of Dublin, Building Standards, of one signed copy of the addendum to the submitted plans. TO REQUEST AN APPEAL HEARING, YOU MUST send a written request, listing the items to be appealed and the relief sought and one copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016-1236 Reviewed and Signed, Ray M. Harp4aAIA Jeffrey S, yler, AIA Commercial Plans Examiner Chief Building Official City of Dublin City of Dublin Signature - Architect, Engineer or contractor Date P'(IlV'i%4eA Lef"45 - I cet'~7- Print Name and Title as Signed Page 2 of 2 CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 Supplement to Walk Through Plan Approval Application Date: 2/29/2008 Application Number: 08 -200197 Property Address: 555 METRO PL N Project Description: MAHINDRA #390 THIS IS NOT A BUILDING PERMIT. IT IS A SUPPLEMENT TO OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT This SUPPLEMENT TO THE PLAN APPROVAL is issued by the City of Dublin, Division of Building Standards. Listed below are items which may not appear in the construction documents, but which are not considered to constitute a hazard serious enough to warrant withholding Plan Approval. The fo/lo wing items are conditions of the issuance of the Plan Approval,, when applicable. Item 1. OBC. 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the the building official or the building official's designated representative. Item 2. OBC 105.7.2 Posting. The certificate of plan approval shall be posted in a conspicuous location outside of the building and in the front part of the premises on which is, or will be the approved building or equipment to which the approved plans relate. The owner and the contractor shall, so far as possible, preserve and keep the certificate posted until the completion of the work to which the approved plans relate. Item 3. OBC. 106.4 Amended construction documents. If substantive changes to the building are contemplated after first document submission, or during construction, those changes must be submitted to the building official for review and approval prior to those changes being executed. The Building official may waive this requirement in the instance of an emergency repair or similar instance. Item 4. OBC 109.1 General. Construction or work for which an approval is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. This includes firestopping and draftstopping (Chapter 7 OBCJ, mechanical workpiping, ducts and systems Chapter 3 OMCJ, structural members and connections (Chapter 16, OBCJ, and electrical work /Chapter 27 OBCJ. Existing electrical conductors, if removed, abandoned, or altered, shall be accomplished to the electrical field inspector's appro val. Electrical work found not to meet the code's standards shall be corrected to the electrical field inspectors approval All systems and elements co vered by code are to be inspected and appro ved before being co vered. Page 1 of 2 _ _ r r~.rrrorrrrrwr CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200197 Date 3/14/08 Property Address . . . . . . 555 METRO PL N Parcel Number: 273-001344 Alternate Address: METRO CENTER Tenant nbr, name . . . . . . 390 MAHINDRA #390 Application type description COM BUILDING ALTERATION Property owner . . . . . . . PARKVIEW LIMITED P/S Contractor . . . . . . . . . CHAMPION SERVICES, LLC Structure Information 000 000 Construction Type . . . . . 1B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . COMMERCIAL BUILDING PERMIT Additional desc . . 3,054 SQUARE FEET Permit Fee . . . . 400.00 Plan Check Fee .00 Issue Date . . . . 3•, 1$.O$ Valuation . . . . 0 Expiration Date . . 9/10/08 Qty Unit Charge Per Extension BASE FEE 160.00 3.00 80.0000 THOU COM BLDG PLAN REVIEW 240.00 Special Notes and Comments IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED ` CHIEF BUILDING OFFICIAL e ey S. Tyler, AIA Other Fees . . . . . . . . . COM BLDG INSPECTION ALT 180.00 COM CERTIFICATE OF OCC 120.00 SURCHARGE FEE - BLDG 21.00 Fee summary Charged Paid Credited Due Permit Fee Total 400.00 .00 .00 400.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 321.00 .00 .00 321.00 Grand Total 721.00 .00 .00 721.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. ...-..r~+r.i •.rrrrrr.•iroma.n+r+r CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Date Application No. ©V APPLICATION FOR ELECTRICAL PERMIT, Job Address .~SS S- A Ara l ~2~-e J • Parcel No dA;1%. J7py Subdivision Lot No. Owner Name k* 4 ` '0DZA" Telephone Contractor Name K T"' Telephone 6,444(a-)-3 ~0 Contractor Address & __/_0 LCL4 1f moo/ Z,Z`j Dublin Registration No. Residential: New Sq. Ft. Alteration/Addition Sq. Ft. Temporary Service $40.00 $40.00 Minimum plus $20.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Low Voltage Systems: Square Feet $40.00 Minimum plus $10.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Commercial: New Sq. Ft. 30S Alteration/Addition Sq. Ft. Temporary Service $60.00 $60.00 Minimum plus $60.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. and up to 50,999 Sq. Ft. (sizes above, See Fee Schedule) Low Voltage Systems: Square Feet $30.00 Minimum (plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.) 3% State of Ohio Surcharge (commercial only) Total $ JOB DESCRIPTION .21JS 1 ptLL=0~l~1~r~ rC~'I.cl cJ I P f~` This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of Dublin, all the laws of the State and the National Electric Code regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any rovisions of said la Signature of licensed contractor or homeowner Division of Building Standards •©v Date: 1/1/2001 CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200197 Date 4/04/08 Property Address . . . . . . 555 METRO PL N Parcel Number: 273-001344 Alternate Address: METRO CENTER Tenant nbr, name . . . . . . 390 MAHINDRA #390 Application type description COM BUILDING ALTERATION Property owner . . . . . . . PARKVIEW LIMITED P/S Contractor . . . . . . . . . CHAMPION SERVICES, LLC Structure Information 000 000 Construction Type . . . . . 1B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . LOW VOLTAGE ELECTRIC PERMIT Additional desc . . Permit Fee . . . . 90.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/01/08 Qty Unit Charge Per Extension BASE FEE 30.00 3.00 20.0000 THOU COM ELECTRIC LOW VOLTAGE 60.00 Special Notes and Comments IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA Other Fees . . . . . . . . . SURCHARGE FEE - ELECTRIC 9.90 Fee summary Charged Paid Credited Due Permit Fee Total 90.00 .00 .00 90.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 9.90 7.20 .00 2.70 Grand Total 99.90 7.20 .00 92.70 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. - CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Date 6 ~0 -Z Application No. O ,~C 00P 1 APPLICATION FOR ELECTRICAL PERMIT Job Address S~r,57 /11grTg -6 4g~P_ N'. Parcel No 2 -7 °d d 1 -_S / Z -L/ Subdivision Sid. t Te- 3/ 0 Lot No. Owner Name kA t /1 Je fl- Telephone Contractor Name, e-A h Telephone 61` 6 Contractor Address2ni °S€~~r's7oce5''1 Dublin Registration No. 0 Residential: New Sq. Ft. Alteration/Addition Sq. Ft. Temporary Service $40.00 $40.00 Minimum plus $20.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Low Voltage Systems: Square Feet $40.00 Minimum plus $10.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Commercial: c/ New Sq. Ft. Alteration/Addition Sq. Ft. 1 ` Temporary Service $60.00 $60.00 Minimum plus $60.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. 2L/d and up to 50,999 Sq. Ft. (sizes above, See Fee Schedule) Low Voltage Systems: Square Feet $30.00 Minimum (plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.) 3% State of Ohio Surcharge (commercial only) -7,20 Total $ 20 7. 20 c~ "Xt S Ti ?t ~~i1?1 f1 S pf~~ D'a JOB DESCRIPTION t ` e-ol This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of Dublin, all the laws of the State and the National Electric Code regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. Signature of licensed contractor or homeowner Division of Building Standards Date: 1/1/2001 _ir r CITY OF DUBLIN Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 08-00200197 Date 3/26/08 Property Address . . . . . . 555 METRO PL N Parcel Number: 273-001344 Alternate Address: METRO CENTER Tenant nbr, name . . . . . . 390 MAHINDRA #390 Application type description COM BUILDING ALTERATION Property owner . . . . . . . PARKVIEW LIMITED P/S Contractor . . . . . . . . . CHAMPION SERVICES, LLC Structure Information 000 000 Construction Type . . . . . 1B - PROTECTED/NONCOMB Occupancy Type . . . . . . BUSINESS Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 240.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 9/22/08 Qty Unit Charge Per Extension BASE FEE 60.00 3.00 60.0000 THOU COM ELECTRIC SERVICE 1K-50K SF 180.00 Special Notes and Comments IF IN THE COURSE OF CONSTRUCTION, WORK IS DELAYED OR SUSPENDED FOR MORE THAN SIX MONTHS, THE APPROVAL OF PLANS OR DRAWINGS AND SPECIFICATIONS OR DATA IS INVALID. TWO EXTENSIONS SHALL BE GRANTED FOR SIX MONTHS EACH IF REQUESTED BY THE OWNER AT LEAST 10 DAYS IN ADVANCE OF THE EXPIRATION OF THE APPROVAL AND UPON PAYMENT OF A $20.00 EXTENSION FEE SIGNED CHIEF BUILDING OFFICIAL Jeffrey S. Tyler, AIA Other Fees . . . . . . . . . COM BLDG INSPECTION ALT 180.00 COM CERTIFICATE OF OCC 120.00 SURCHARGE FEE - ELECTRIC 7.20 SURCHARGE FEE - BLDG 21.00 Fee summary Charged Paid Credited Due Permit Fee Total 240.00 .00 .00 240.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 328.20 321.00 .00 7.20 Grand Total 568.20 321.00 .00 247.20 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. ENVIRONMENTAL BALANCING CO, INC. DIFFUSER & GRILLE TEST SHEET g! 2VOf ?7 P.O. BOX 387 project l` 55 M~"71~0 Pz k - M~Ifflti'D2A U WESTERVILLE, OH 43086-0387 Date:. 5/Z--7 Phone: 614-890-2824, Fax: 614-882-6881 Page. Unit Plan Outlet Free Req'd Req'd Set Set . Remarks No. Location Size Area CFM Velocity CFM Velocity 0 U ~ fJ ~5 ~ "vv 2 IL ~S IBS 7© X70 OO 1iS ~t~ jl~ '500 5 ~S 1 1-76 I-IS ~7 17D 00 ~gS ~d S2a 3 -7 L9 0 9p V0v IS' 3P4 /O v 310 ~!z> Joseph W. Testa, Franklin County Auditor Page 1 of 1 Joseph W, Testa, Audif i Street Address Summary 1 of 1 Parcel ID Address Index Order Card Parcel Info 273-001344-00 555 S METRO PL Street Address 1 of 1 Summary - Print View Owner Information Tax Bill Mailing Residential Call 614-462-4663 if incorrect Information Commercial !e+! 555 METRO LLC Mail Changes Only - Click Improvements 555 METRO PLACE Here Sketch/Photo DUBLIN OH 43017 NATIONAL TAX SEARCH LLC Map (GIS) C N A MARY FEHL Transfer 303 E WACKER DR STE 850 Property Report CHICAGO IL 60601-5222 Tax Information Levy Info Value Information Legal Description Tax Estimator Market Land Value 1,472,800 555 METRO PL S Tax Distribution Agricultural Value 0 METROCENTER Market Impr. Value 3,727,200 5.635 ACRES LOT 5 Search By Market Total Value 5,200,000 273-NO90BBB -009-01 Parcel ID Sales Data Building Data Owner Sale Amount $5,200,000 Year Built 1979 Street Address Date 08/04/2006 Deed Type LW Site Functions # of Parcels 1 Property Search Conveyance # 19046 On-Line Help Exempt # Email Auditor 273 CITY OF DUBLIN-WASH Board of Revision Yes Home Tax Dist TWP-DUBLIN CSD Homestead No Auditor's Home School Dist 2513 DUBLIN CSD 2.5% Reduction No Tax Estimator by [449] ELEVATOR OFFICE Assessments No School/District Land Use BUILDING (3+ STORIES) CDQ Year Contact Us Neighborhood 00105 2007 Annual Taxes $144,225.82 2007 Total Taxes Paid $144,225.82 Print Back to List I << First < Previous Next > Last Data updated on 06/20/2008 ,._...~.._....._...,d,. w~MflYriiltl5W11Y - llfiyllW?IYMY1•~fllfil•'IM a Building Standards Revision to Application for Building Permit 5800 Shier Rings Road g Dublin, Ohio 43016-1236 (Commercial and Residential) Phone: (614) 410-4670 Fax: (614) 410-6566 This worksheet is for revisions to plans that have been assigned an application number and have been given plan approval by this department. Date: Revision Number: Fee: c Original Application Number: D8~ Z~~ 97 8 Project Address: ~SS/`~E`~/°L.9CE/~/• SG//7'•3~~ L Project Name: y o Owner Name: C~~9G?,d. f/O y//t/G ,S'/Y/ Tenant Name: 14 /A 11W4 eA Contact Name: 04ZIAI 4411A:0_9 Phone: ~0l'9' ~pZ 100 • .~aN~-die L~~TE~ Company Name: CA4eV.J.FY Address. -15745'49 Fax: z ~l90! Qc/4q,L, A1.01110 -V3016 E-mail: D.el ,t ie~' C.O~',r~/~,~/~1 Provide a comprehensive description of the revision(s) being submitted (please attach additional information, if necessary): CM~AI(9E0 0=45 300 g 3oie,serarr 5'~P.~ecac/r ~b~LG G~[.9>~.S cr•/~~~ LOC. a X •L W, 40 40 A C O Revision Type ~i Check the types of revisions being submitted with this application: Architectural ?Structural 0 Electrical 0 HVAC ?Plumbing DEngineering OLandscaping 0 Zoning The owner of this building and the undersigned, do hereby covenant and agree to comply with all the laws of the State of Ohio and the Ordinances of this jurisdiction, pertaining to the building and the buildings, and to construct the proposed building or structure or make 6 the proposed change or alteration in accordance with the plans and specifications submitted herewith, and certify that the information and statements given on this application, drawings and specifications are to the best of their knowled e, true and correct. a e< A9AR11V 14UA14ie -AeeW170011 Applicant's Printed Name Applicant's CD cargey iN*,ranker ARCHITECTS ltd RECEIVED April 8, 2008 J1 2008 Mr. Ray Harpham, Plans Examiner BUILDING DIVISION City of Dublin Building Department CITY OF DUBLIN 5800 Shier Rings Road Dublin, Ohio 43017 RE: Mahindra 555 Metro Place North Suite 390 Permit Number 08-200197 Dear Mr. Harpham, Attached are floor plans indicating clarification on a couple of issues requested by the field inspector. We have shown a furniture layout indicating that a 3'-0" finish dimension shall be held for required egress. Doors 300 and 304 were originally approved as aluminum storefront. Full glass herculite doors have been installed with magnetic locks and card access control. Both shall be `fail-safe' for egress within the tenant space to the common area stair locations. Please call to discuss if you have any questions or need any additional information. Sincerel Darin J. Ranker Architect O CO DARIN ~r I J. RANKER V tr 12529 RED a~ 5980 Wilcox Place Suite J Dublin, Ohio 43016 614-792-1000 Ph. 614-792-1001 Fax 0 3 J . 3 M_ z SERVER ROOM ' MGR CUBE D O O j 8x12 O r_ " 2 ^ I O l ~ L-11 O j MGR CUBE 8x12 301 Q r----------- WORKROOM 304` 304 j MGR CUBE ~ t ' 2 OPEN WORK 8x12 U) Z) Z H 3-0" ul oQ z ~ D g a o 300 2Q 302 I W Q g 300 H C RECEPTION CD p~pp~p ~p ? G u,n ENV- GLASS HERCULITE TYPE 3 ° a DOORS W/ MAG LOCK AND o a LL CARD ACCESS CONTROL. SPRINKLER DRAWINGS (1 HEAD ON EACH SIDE OF THE FRONT GLASS ENTRY DOOR . NOTE: HAVE BEEN SUBMITTED AND TRAVEL DISTANCE FOR I;~ F~ APPROV ° VACANT ADJACENT C u mahindra OF SPACE=71 9" Cc~ s ~ METRO II 6/9/08 DARIN a A 6 / 12 / 08 RANKER v 12528 AREA OF WORK D third floor key plan 1.0 Building Standards Revision to Application for Building Permit 5800 Shier Rings Road g Dublin, Ohio 43016-1236 (Commercial and Residential) Phone: (614) 410-4670 Fax: (614) 410-6566 This worksheet is for revisions to plans that have been assigned an application number and have been given plan approval by this department. as O Date: DQ Revision Number: Fee: . o Original Application Number: ~8' Project Address: /4f0WW N SelPIO -374V M Project Name: /V,41'11vJOR4 RECEIVED W Owner Name: 'C'IeWr-040 5 A10y1NG = S H1771 a APR 16 2008 Tenant Name: 1t-1A,1WW49 ~ Contact Name: Phone: CITY OF DUBLIN Company Name: 8 v, Address: Fax: ~9~ • ~C/8~/!ti/, D!1 •'~,3~/~ E-mail: Provide a comprehensive description of the revision(s) being submitted (please attach additional information, if necessary): 4!!F1 A006D OX197_icelt; 4,GOSA::Pl' y A a ~,evision ~'y~e Check the types of revisions being submitted with this application: MArchitectural ?Structural ? Electrical ? HVAC ?Plumbing ?Engineering ?Landscaping ? Zoning The owner of this building and the undersigned, do hereby covenant and agree to comply with all the laws of the State of Ohio and the Ordinances of this jurisdiction, pertaining to the building and the buildings, and to construct the proposed building or structure or make the proposed change or alteration in accordance with the plans and specifications submitted herewith, and certify that the information and statements given on this application, drawings and specifications are to the best of th ' true and correct. a°c Applicant's Printed Name App is e i A4/14/2008--.0- 4411 305 R BREAK AREA R R O DARIN ~r * I RANKER V 12529 F CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 Supplement to Walk Through Plan Approval Application Date: 2/29/2008 Application Number. 08 -200197 Property Address: 555 METRO PL N Project Description: MAHINDRA #390 THIS IS NOT A BUILDING PERMIT. IT IS A SUPPLEMENT TO OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT This SUPPLEMENT TO THE PLAN APPROVAL is issued by the City of Dublin, Division of Building Standards. Listed below are items which may not appear in the construction documents, but which are not considered to constitute a hazard serious enough to warrant withholding Plan Approval. The fo/lo wing items are conditions of the issuance of the Plan Approval, when applicable Item 1. OBC. 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the the building official or the building official's designated representative. Item 2. OBC 105.7.2 Posting. The certificate of plan approval shall be posted in a conspicuous location outside of the building and in the front part of the premises on which is, or will be the approved building or equipment to which the approved plans relate. The owner and the contractor shall, so far as possible, preserve and keep the certificate posted until the completion of the work to which the approved plans relate. Item 3. OBC. 106.4 Amended construction documents. If substantive changes to the building are contemplated after first document submission, or during construction, those changes must be submitted to the building official for review and approval prior to those changes being executed. The Building official may waive this requirement in the instance of an emergency repair or similar instance. Item 4. OBC 109.1 General. Construction or work for which an approval is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. This includes firestopping and draftstopping /Chapter 7 OBC), mechanical work- piping, ducts and systems (Chapter 3 OMC/, structural members and connections CChapter 16, OBC), and electrical work /Chapter 27 OBCJ. Existing electrical conductors, If removed, abandoned, oraltered, shall be accomplished to the electrical field inspector's approval. Electrical work found not to meet the code's standards shall be corrected to the electrical field inspector's approval. All systems and elements covered by code are to be inspected and approved before being covered. Page 1 of 2 Item 6. OBC 1 103.1 Where required. Building and structures, temporary or permanent, including their associated sites and facilities, shall be accessible to persons with physical disabilities. OBC 1 103.2.1 Specific requirements. Accessibility is required in building and facilities, or portions thereof, to the extent indicated in ADAAG Section 4.1 and this chapter. The start of construction indicates acceptance of all the conditions listed above. This review does not preclude the necessity to conform to provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rest with the registered design professional, the tenant and the owner. Plan Approval will be valid only upon receipt by the City of Dublin, Building Standards, of one signed copy of the addendum to the submitted plans. TO REQUEST AN APPEAL HEARING, YOU MUST send a written request, listing the items to be appealed and the relief sought and one copy of this order to: Jeffrey S. Tyler, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016-1236 Reviewed and Signed, Ray M. Harpham, AIA Jeffrey S. Tyler, AIA Commercial Plans Examiner Chief Building Official City of Dublin City of Dublin Signature - Architect, Engineer or Contractor Date Print Name and Title as Signed Page 2 of 2 CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 41 G4680 Walk Through Lice of Review Building Fire Zoning (This is not a building permit Application Date: 2/29/2008 Application Number: 08 -200197 Property Address: 555 METRO PL N Project Description: MAHINDRA #390 Fire Alarm Application No.: Fire Suppression Application No.: y/p Sprinkler System Required: System Demand: /SOD glom ~m~il~ Special Hazard Classification: Light ? / Square Footage: 3,054 ? Occupancy Load: ,3Q Construction Type: 1 B Use Group: B Result of plan review: V Approved 1/w0i k*4p) Submit signed changes/revisions prior to: Disapproved, reschedule walk through with revised documents Disapproved, resubmit under the regular permit process The following items must be addressed: 1. Field verify existing, additions and changes to horn/strobe location and actuation 2. Field verify emergency egress and exit lighting 3. All fire protection systems require a separate permit ( j+e Q/0111 4. `i,7121wA,le vh calocY 30 54 ~'ewwer oil /p['P/oT'Q'1 s'i Q"e • ~ 5. 6. 7. 8. Reviewed by: Gf~' o A;e Document Created/Revised I/ 1 /08 CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 W ough Notice of Review (Building) Fire Zoning (This is not a building permit Application Date: 2/29/2008 Application Number: 08 -200197 Property Address: 555 METRO PL N Project Description: MAHIN Alarm Application No.: Z2L Fire Suppression Application No.: Sprinkler System Required: System Demand: Special Hazard Classification: Square Footage: 3,054 Occupancy Load: 3O Construction Type: 1 B Use Group: B Result of plan review* Approved Submit signed changes/revisions prior to: Disapproved, reschedule walk through with revised documents Disapproved, resubmit under the regular permit process The following items must be addressed: 1. Field verify existing, additions and changes to horn/strobe location and actuation 2. Field verify emergency egress and exit lighting 3. All fire protection systems require a separate permit 4. 5. 6,~ t'l Lam 7. 8. Reviewed by: Document Created/Revised 1/1/08 CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 Walk Through Notice of Re iew Building Fire Zoning (This is not a building permit) Application Date: 2/29/2008 Application Number: 08 -200197 Property Address: 555 METRO PL N Project Description: MAHINDRA #390 Fire Alarm Application No.: Fire Suppression Application No.: Sprinkler System Required: System Demand: Special Hazard Classification: Square Footage: 3,054 Occupancy Load: Construction Type: 1 B Use Group: B Result of plan review: Approved Submit signed changes/revisions prior to: Disapproved, reschedule walk through with revised documents Disapproved, resubmit under the regular permit process The following items must be addressed: 1. Field verify existing, additions and changes to horn/strobe location and actuation 2. Field verify emergency egress and exit lighting 3. All fire protection systems require a separate permit 4. S , n All Service ;Ztri jrjvrPc-; 5. & N-lecha ical Urg"AS PER G! L 10MOTON 7. 8. Reviewed by: 7-f f 77 74-- /r O I7nn imam rraatarl/Rcvimri t / t mQ CERTIFICATE OF ZONING PLAN APPROVAL APPLICATION Z-~ L DATE ISSUED /Z Land Use and Long Range Planning 5800 Shier-Rings Road Dublin, Ohio 43016-1236 Phone/ TDD: 614-=-4600 Fax: 614-410-4747 Web Site: w .dublin.oh.us NAME F U INE FA LITY (IF APPLICABLE) ADD SS O S BJECT PR ERTY NAAWF PLIC O GENT PHONLW- I ADDRE5SUF APPLICANT/ AUTH ZED AGE NAME F PROPERTY OWNER' PHONE PLEASE DESCRIBE IN LAYMAN'S TERMS THE EXISTING AND PROPOSED USE(S) OF ALL PARTS OF THE LAN AND/OR BUILDINGS. IF A CHANGE OF USE IS PROPOSED, PLEASE EXPLAIN. (IE, RETAIL SPACE TO MEDICAL OFFICE SPACE, ETC.)_ D~FI139 /~iecaDOrS'~D G/rt/EE~~N~ PLEASE SUBMIT THE FOLLOWING: ONE (1) ORIGINAL SIGNED APPLICATION ONE (1) COPY OF A SCALED SITE PLAN DRAWN IN INK indicating all current and proposed land uses, structures, and other site improvements. Additional documentation may be required for various types of projects. Partial or incomplete applications and drawings cannot be processed and will be returned to the applicant by mail. APP DATE: 3•x/•08 FOR OFFICE USE ONLY CASE NUMBER DATE CASE NUMBER DATE CASE NUMBER DATE NOTES: Screen All Service Structures & Mechanical Units PER CITY CODE CALL PLANNING DIVISION ZONING INSPECTION REQUIRED UPON COMPLETION? ? YES 'NNO If yes, please call 614-410-4680 to schedule an inspection. A Ce 1 of zoning compliance will be issued after the work is inspected and approved by Land Use and Long Range Planning. ? APPROVED APPROVED AS NOTED This Certificate of Zoning Plan Approval is issued for, and n r rence to the property and use described above, and as approved by the City Administrator or designee, or the City Council, Board of Zoning Appeals, Planning & Zoning Commission, or the Architectural Review Board as appropriate. ? DIS PROV AS BY: DATE: Z CERTIFICATE OF ZONING PLAN APPROVAL 3/1012006 C c e Software Version 3.5.2 Interior Lighting and Power Compliance certificate 90.1 (2004) Standard Report Date: 03/oe/oti Data fitenarm: Untftled,cck Section 1: Project Information Project Type: Alteration Project "title : Mahindra Construction Site: Owner/Agent: Designer/Contractor: 555 Metro Place Bruce Vetter Dublin, OH 43017 VMP Englawring,inc. 6631 Commerce Parkway Studio C Dublin, OH 43017 614-40e-3862 bvetter@vmpengineedng.cm. Section 2: General information Building Use Description by: Activity Type Activity Area Compliance Exemption Qualtfications Total Wattage Total Pre-ML k fixtures Activity Area re-AIL P4 a4- t. Fixtures RWJAdded Common Space Types;Office - Open Plan (3006 sq.tt.): Exemption: 6280 5480 89 0 Less than 50% fixture replacement. Section 3: Requirements Checklist Interior Lighting:. L3 1, Total proposed watts must be less than or equal to total allowed watts. Allowed Wafts Proposod Watts Compiles N/A N/A Passes © 2. Exit signs 5 Watts or less per side. Controls, Switching, and Wiring: C7 3. independent mnual or occupancy sensing controls for each space (remote switch with indicator allowed for safety or security). © 4. Occupant sensing control In class rooms, conference/meeting roatts, and employee lunch and break rooms. Exceptions: Spaces with multi-scene control; shop classrooms, laboratory classrooms, and preschool through 12th grade ciassrooms. -5. Automatic shutoff control for lighting in >5W O sq.ff buildings by dme-of-day device, occupant sensor, or other automatic control. E rcoMions: 24 hour operation lighting; parent care areas: where auto shutoff would endanger safety or security. D 6. WSW SAO at entry to hotellmotel curt roam. 7. Separate control device for display/aocent lighting, case fighting, task fighting, nonvisusl fighting, lighting tlog for sale. and demonstration . C3 8. Photooelliastronomical time switch on exterior lights. Exceptions: Covered vehicle entrance/exit areas requiring lighting for safety, security and eye adaptation. Protect Titre: Mahindra 1061:.8 Data tllename: Untidedxck Repoli die: Pasta 1 of 3 9. Tandem wired one-tamp and three-lamp ballasted luminaires (No single-lamp ballasts). Excepfiorrs: Electronic high-frequency ballasts; Luminaires not on some switch; Recessed luminaires 10 ft, apart or surface/pendant not continuous, Luminaires on emergency circuits. Vo ttage Drop: C1 10. Feeder conductors have been designed for a maximum voltage drop of 2 percent.. 0 11. Branch circuit conductors have been designed for a maximum voltage drop of 3 percent. 0 12 Voltage drop analysis must include the parts of the existing system extendang#to the point of electrical supply at the transformer or service equipment entrance. Section 4. Compliance Statement Corfoftnce Statement: The proposed lighting alteration project represented in this ment Is consisleni with the building plans, specifications and other calculations subrn fitted with this permit apptia~t. The propo lighting ration project has been designed to meet the 90.1 (2004) Standard, Chapter 8, requirements In COMchei k Version 3 .2 to y wilt the mandatory regtprarrents, in the Requirements Checklist I Michael bunter - Designer ' Name Title Si Ature Bate Section 5: Post Construction Compliance statement Record Drawings and Operating and Maintenance Manuals: 0 1. Construction documents with record drawings and operating and maintenance manuals provided to the owner. Lighting Designer or Contractor Name Signature Date Project Titla: l4Aahindra ~..r... m Data filename: Untitled.cck Report date. 03A)&Q8 Page 2 of 3 CO check Software Version 3.5.2 Interior Lighting Application Worksheet 94.1 (2444) Standard Report Grate: Data filename; unvtw.cckc Section 1. Allowed Lighting Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (1`12) Watts I ft2 (B X C) Total Allowed Watts = 0 Section 2: Proposed Lighting Power Calculation A 6 C D E Fixture ID ; Descr r n I Lamp I WoUaga Par tamp I Bailast tamps/ # of Fixture (C X D) Fixture Fixtures Watt. Total Proposed Watts = 0 Section 3. Compliance Calculation If the Total Allowed Watts minus the Total Proposed Watts is greater than or equal to zero, the bung oompiies. Total Allowed Watts = 0 Total Proposed Watts 0 Project Compliance w 0 Project Tlfle. btatlindra Data filename: Unlitied.cck Report data: 03 rd PP am A 3 ear 't or: P~cE.~,~y BUILDING CODE DATA o~RiN '~.~o J. , ECTURAL NOTES NERAL ARCHIT GE ~ ; RANKER USE GROUP - B E 2001. 13. IN ANY ROOM IN WHICH PLUMBING, HEATING, OR ELECTRICAL ALTERATIONS 1. GOVERNING CODE ~ OHIO BUILDING COD ARE MADE THE CONTRACTOR REQUIRING CUTTING INTO EXISTING WORK SHALL ~ CONSTRUCTION TYPE-1B 'G'~•'•. ~252g THIS IS A "BUILDERS SET" OF DRAWINGS, THE ARCHITECT'S RESPONSIBILITY MAKE PROPER REPAIRS TO OTHER BUILDING ITEMS AFFECTED (LE,, FLOORS, 2. a ~ ~ n I I ~ OCCUPANCY-OFFICE ~f~•' • • • ~ IS LIMITED TO THE ITEMS SHOWN ON THE ARCHITECTURAL DRAWINGS, OBTAIN WALLS, CEILINGS, BASE, CHAIR RAIL, TRIM ETC.). ARCHITECT'S SPECIFIC APPROVAL PRIOR TO DEVIATING FROM THE DRAWINGS. 14. ALL CONNECTIONS ARE TO DEVELOP THE FULL STRENGTH OF THE FRAMING IT SHALL BE THE CONTRACTOR'S SOLE RESPONSIBILITY TO COMPLY WITH MEMBERS, UNLESS OTHERWISE APPROVED. ¦ ALL DRAWINGS IN THIS SUBMITTAL HAVE BEEN PREPARED UNDER STANDARD BUILDING AND CONSTRUCTION PRACTICES AND AND ALL ITEMS NOT SPECIFICALLY 15. BOLTING OF WOOD TO STRUCTURAL MEMBERS OR MASONRY SHALL BE IN MANUFACTURERS RECOMMENDATIONS FOA GENERAL WITH A MINIMUM OF 112"' DIA~ ANCHOR BOLTS AT 4'-0" O.C. EXCEPT ~ THE 2007 EDITION OF THE OHIO BUILDING CODE AND IN INDICATED AND DETAILED ON THE DRAWINGS. FOLLOW THE BEST TRADE E WISE. SITUATIONS REQUIRING SPECIAL BOLTING SHALL ~ ~ ACCORDANCE WITH THE 2007 EDITION OF THE OME, OPC, AND NEC, PRACTICES AND ENGINEERING FOR THE ITEMS NOT SPECIFICALLY DETAILED WHERE SHOWN OTH R BE WITH THE SIZE AND SPACING OiF BOLTS TO SUIT THE CONDITIONS, EMERGENCY POWER FOR EXIT SIGNS AND EMERGENCY EGRESS ~ • AND INDICATED, ANCHORING OF WOOD TO STRUCTURAL MEMBERS, OA CONCRETE SHALL BE, IN LIGHTING IS PROVIDED THROUGH A BATTERY BACK-UP WIRED 3, DIMENSIONS SHOWN ARE FROM FACE OF MASONRY OR TO FACE OF STUD, GENERAL, WITH STRAP ANCHORS (FIXED IN PLACE WITH EXPANSION ANCHORS AHEAD OF ANY LOCAL SWITCHING, UNLESS NOTED OTHERWISE OR POWER DRIVEN ANCHORS. THE EXISTING BUILDING HAS AN ENUNCIATED AUTOMATIC FIRE ~ HALL BE VERIFIED AT THE JOB BY THE GENERAL LINTELS OR HEADERS OVER ALL OPENINGS INCLUDING THOSE 4, ALL DIMENSIONS S 16. PROVIDE PROTECTIVE SIGNALING SYSTEM, WITH LOBBY AND STAIR PULL CONTRACTOR AND EACH SUBCONTRACTOR. THE ARCHITECT MUST BE REQUIRED FOR DUCTWORK, PIPES, LOUVERS, GRILLES, DAMPERS, ETC. STATIONS, AND AUDIBLE AND VISUAL ALARMS IN ALL PUBLIC NOTIFIED OF ANY DISCREPANCIES PRIOR TO COMMENCING WORK. 17. FILL ANY MASONRY VOIDS WITH MORTAR OR CONCRETE WHERE ANCHORS SPACES, 5. THESE DOCUMENTS WERE PREPARED ON THE BASIS OF EXAMINATION OF OCCUR VISIBLE PORTIONS OF THE EXISTING STRUCTURE, THE ARCHITECTS( L OR ELEVATIONS 100'-0" TO MATCH EXISTING EXISTING ATRIUM IS SEPARATED FROM LOBBY AND CORRIDOR ~ SPACE ON EACH FLOOR BY A FIRE SHUTTER WITH FUSIBLE LINK, ~ ENGINEERS ASSUME NO RESPONSIBILITY FOR ANY SITUATIONS, DIMENSIONS, 18. BENCH MARK; NEW FINISH F 0 BUILDING ELEVATION UNLESS NOTED OTHERWISE. ~ ~ OR OTHER CONDITIONS OF THE EXISTING STRUCTURE WHICH MAY ARISE AND INTERCONNECTED TO AN INDIVIDUAL SMOKE DETECTOR AT DURING DEMOLITION OA CONSTRUCTION, 19, THE COURSING OF ALL MASOfNRY IS TO MATCH THAT IN THE EXISTING EACH FLOOR , TOP OF ATRUIM HAS AUTOMATIC OPENING FOR 0 BUILDING, THE CONTRACTOR IS TO VERIFYALL DIMENSIONS AND PROFILES OF SMOKE RELIEF, 6. SHOULD ANY OF THE DETAILED INSTRUCTIONS SHOWN ON THE DRAWINGS STONE AT THE SITE CONFLICT WITH THESE NOTES, STRUCTURAL NOTES, THE SPECIFICATIONS, OR T RE IN ANY WAY EACH OTHER THE STRICTEST PROVISION SHALL GOVERN. 20. EQUIPMENT FRAMING LOADS„ OPENINGS AND STRUC U WITH , RELATED TO HVAC, PLUMBING, OR ELECTRICAL REQUIREMENTS ARE SHOWN - SCOPE OF WORK 7, THE GENERAL CONTRACTOR SHALL COMPLY WITH ALL BUILDING CODE FOR BIDDING PURPOSES ONLY. CONTRACTORS SHALL OBTAIN APPROVAL OF AN EXISTING SUITE 3901S EXPANDING INTO ADJACENT OFFICE REQUIREMENTS THE LOCAL GOVERNING AUTHORITY, AND SHALL OBTAIN AND THE TRADES INVOLVED BEFORE PROCEEDING WITH SUCH PORTION OF THE PAY FOR ALL REQUIRED PERMITS, FEES, AND INSPECTIONS, WITH THE WORK. EXCESS COST RELATED TIO VARIATION IN THESE REQUIREMENTS ARE TO SPACE WITH DEMOLITION AND ALTERATIONS WITH NEW FINISHES, EXCEPTION OF FEES REQUIRED FOR THE PLUMBING, HVAC, AND ELECTRICAL BE BORNE BY THE APPROPRIATE (DONTRACTOR. _ ~ ~ ~ ~ , 61 Ohio 430 x Place Dublin , 5980)1X/ilco , Ph. 614-79Z-1000, Fix 614-79Z-1001 PORTIONS OF THE WORK, WHICH ARE THE RESPONSIBILITY OF THE RNISHED AND WORK PERFORMED UNDER THE RESPECTIVE SUBCONTRACTORS, 21. ALL EQUIPMENT FU CONTRACT DOCUMENTS SHALL BIE GUARANTEED AGAINST DEFECTS IN 8. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW THE MATERIALS AND WORKMANSHIP FOA A PERIOD OF ONE (1) YEAR FROM THE APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF DATE OF FINAL ACCEPTANCE. ANIY FAILURE OF EQUIPMENT OR WORK DUE TO • CONSTRUCTION. DEFECTS IN MATERIAL OR WOAKh~iANSHIP SHALL BE CORRECTED BY THE CONTRACTOR AT NO COST TO THIE OWNER, 9. PERFORM DEMOLITION AS INDICATED ON PLANS AND DETAILS AND AS ULE NCRETE CURBS AND EQUIPMENT PADS SHALL BE FURNISHED BY THE lrie e TE .SCHED 22. ALL CO Jll REQUIRED FOR THE COMPLETION OF THE PROJECT AS INDICA D ineering Inc g . • AND PERFORM DEMOLITION PROCEDURES TAKING NECESSARY PRECAUTIONS GENERAL CONTRACTOR AND SIZED AND LOCATED BY THE CONTRACTOR TO PREVENT WATER DAMAGE TO THE EXISTING STRUCTURE. ~ INSTALLING THE EQUIPMENT, UNLESS NOTED OTHERWISE. 631 Commerce Parkwa Dublin 0 b y Dublin Ohio, 43017 - 10, DO NOT CUT OR PATCH ANY WORK THAT WILL IMPAIR THE STRUCTURAL 23, SIZE AND LOCATION OF ALL FLOOR AND ROOF OPENINGS ARE TO BE LOAD CARRYING CAPACITY OR REDUCE THE LOADIDEFLECTION RATIO, VERIFIED WITH THE TRADE AFFECTED BEFORE PROCEEDING WITH THE WORK, • 14-408-3 8 b2 • 614-408-3 869 fi 08-3869(fax) DRA1X/ING INDEX b 24, COORDINATE LOCATIONS ANIDIOA ELEVATIONS OF FLOOR DRAINS, 11. PROVIDE ADEQUATE TEMPORARY SUPPORTAND SHORING FOR WORK REGISTERS, ACCESS PANELS, GA~ILLS, LOUVERS, CONVECTORS, CABINET UNIT BEING CUT AND PATCHED TO PREVENT FAILURE, PROVIDE ADEQUATE HEATERS, PANELS, ETC,, WITH MECHANICALAND ELECTRICAL CONTRACTORS, G001 COVER SHEET PROTECTION OF OTHER WORK DURING CUTTING AND PATCHING TO PREVENT PAIR CONDITIONS . CUT WORK BY METHOD LEAST LIKELY TO DAMAGE RETAINED AND 25. IN GENERAL, NEW MATERIALS AND MATERIALS FOR RE Al 01 DEMO AND NEW FLOOR PLAN ,NOTES, AND SECTIONS DAMAGE SHALL MATCH 51MILAR ITEMS IN QUALITY, DETAIL, PROFILE, AND FINISH AS ADJOINING WORK, ~ A1,02 REFLECTED CEILING AND FINISH PLANS AND NOTES THOSE ALREADY BUILT INTO THE WORK. P1 PLUMBING DEMO AND NEW PLAN AND NOTES AND SPECS 12, CUTTING INTO NEW WORK OF OTHER TRADES OR INTO THE EXISTING 26, PATCH ALL WALLS, FLOORS,;AND CEILINGS AND PROPERLY PREPARE ALL , STRUCTURE SHALL BE PERFORMED BY THE TRADE REQUIRING THE CUTTING - LLCUTTING SHALL BE DONE IN A NEAT MANNER USING SAWS WHERE SURFACES FOR NEW FINISHES. BATCH WITH SEAMS WHICH ARE DURABLE AND A - H1 HVAC PLAN, NOTES AND SCHEDULES POSSIBLE ANY DAMAGE TO THE WORK OF THE OTHER TRADES OR TO THE AS INVISIBLE AS POSSIBLE, COMIPLY WITH SPECIFIED TOLERANCES FOR THE E1 ELECTRICAL DEMO PIAN AND NOTES O ING STRUCTURE IN EXCESS OF THE CUTTING REQUIRED, WHICH, IN THE TYPE OF WORK BEING DONE RESTORE EXPOSED FINISHES OF PATCHED AREAS EXIST E2 ELECTRICAL PLAN, LIGHTING PLAN AND NOTES INION OF THE ARCHITECT, IS DUE TO NEGLIGENCE, SHALL BE REPAIRED AT AND, WHERE NECESSARY, EXTEND NEW FINISH RESTORATION ONTO ADJOINING OP THE EXPENSE OF THE TRADE WHO DID THE CUTTING. ALL PATCHING AND RETAINED WORK IN A MANNER WIHICH WILL ELIMINATE EVIDENCE OF PATCHING. PAINTING AS A RESULT OF THE CUTTING AND NOT TO THE NEGLIGENT ACTION P7, CONSTRUCTION JOINTS AAE PERMITTED ONLY WHERE SHOWN OR AS SHALL BE DONE BY THE CONTRACTOR AT HIS EXPENSE. APPROVED BY THE ARCHITECT, ITH )YI ~1G M W • SERVICES ~ 0 Screen Q~I Service Structures ~ ~ ~ & NiecE~anical Units • • • PER CI71' CODE ~ ~ CALL PLAi~NING DIVISION ~ ~ - ~ ~ 0" VIATIONS ABBRE - 0 AFF ABOVE FINISH FLOOR EWC ELECTRIC WATER COOLER MFR MANUFACTURE (R) REV REVISION (S), REVISED Z ~ ~ ADJ ADJACENT EL ELEVATION MAR MARBLE ROW RIGHT OF WAY A!C AIR CONDITIONING EQ EQUAL MAS MASONRY RD ROOF DRAIN a ~ 1'-0" ~ DIMENSION LINE ~ ~ Z TERNATE EXIST EXISTING MO MASONRY OPENING RM ROOM 311 ROOM NUMBER ALT AL ~r W ~ ~ ALUM ALUMINUM EB EXPANSION BOLT MAX MAXIMUM RO ROUGH OPENING OFFICE AB ANCHOR BOLT EXP EXPOSED MECH MECHANIC (AL) SCH SCHEDULE ANOD ANODIZED EXT EXTERIOR MTL METAL SEC SECTION ASPH ASPHALT FOC FACE OF CONCRETE M METER (S) SHT SHEET BRG BEARING FOM FACE OF MASONRY MM MILLIMETER (S) SIM SIMILAR FINISH FLOOR ELEVATION ~ ~ BPL BEARING PLATE FOS FACE OF STUDS MIN MINIMUM SC SOLID CORE 100 DOOR NUMBER BM BENCH MARK FIN FINISH (ED) MIR MIRROR S SOUTH BIT BITUMINOUS FE FIRE EXTINGUISHER MLD MOLDING, MOULDING SPEC SPECIFICATION (S) ~ ~ BLKG BLOCKING FEC FIRE EXTINGUISHER CABINET MT MOUNT (ED), (ING) SQ SQUARE ,rn `~`-u` ,f PROJECT; 07107.041 BD BOARD FLR FLOOR (ING) NRC NOISE REDUCTION COEfFFICIENT SS STAINLESS STEEL BOT BOTTOM FD FLOOR DRAIN NOM NOMINAL STD STANDARD 1 SECTION INDICATOR 1 INTERIOR ELEVATION INDICATION r' ~r~~y„~Y4~~~ ~ DATE; 0310512008 STL STEEL - BLDG BUILDING FTG FOOTER N NORTH TORM DRAIN A1.01 REFERENCED SHEET NUMBER REFERENCED NUMBER ~ ~ ~ ~ MK G.. ~s ~6~ DRAWN BY. CAB CABINET FND FOUNDATION NIC NOT IN CONTRACT SD S CB CATCH BASIN FR FRAME (D),(ING) NTS NOT TO SCALE SUSP SUSPENDED ~ ~~i ~.~,..o-~- ~ CHECKED BY~~ CRH ..W I ~ CLG CEILING FUR FURRED (ING) OC ON CENTER (S) SYM SYMMETRY ((CAL) CEM CEMENT GA GAGE, GAUGE OPG OPENING TEL TELEPHONE A CM CENTIMETER (S) GL GLASS, GLAZING OPP OPPOSITE TV TELEVISION ~ ~ ~ A ' ;,,u-~ ~ SETNLiM; ~ a !f a CT CERAMIC TILE GB GRAB BAR OPH OPPOSITE HAND THK THICK ~ DETAIL INDICATOR COLUMN GRID ~ ~ ~ ~ i4 COL COLUMN HDW HARDWARE OD OUTSIDE DIAMETER T & G TONGUE AND GROOVE ~ CONCRETE HTG HEATING OH OVERHEAD TSL TOP OF SLAB 1 ~ ~ REFERENCED SHEET NUMBER F ~ $ !ef PRIPdTED, CONC T HVAC HEATINGNENTILATIONI PNL PANEL TST TOP OF STEEL CMJ CONCRETE MASONRY UNI A1.01 ~ REVISED: it ~ ~ c ~ ~ u CONST CONSTRUCTION AIR CONDITIONING PTN PARTITION TW TOP OF WALL '~t ~ ~ ~ I Edanb fY~~y CONT CONTINUOUS OA CONTINUE HT HEIGHT PVMT PAVEMENT TB TOWEL BAR CONTR CONTRACT (OR) HC HOLLOW CORE PLAM PLASTIC LAMINATE TYP TYPICAL Y fl CJT CONTROL JOINT HM HOLLOW METAL PL PLATE UR URINAL 1 1. ~ ~ ~ r: ~e r PIS' ,w . ~ ~ ~ CORR CORRUGATED HOR HORIZONTAL PLYWD PLYWOOD VB VAPOR BARRIER - - A1.01 CRS COURSE (S) HB HOSE BIB PUC POLYVINYL CHLORIDE VERT VERTICAL - tl ~ ~ t ~~v ~ ~ ~ 1 ~ REVISION I , Ddrssa'L~ TER NDS PER CUBIC FOOT UB VINYL BASE CFT CUBIC FOOT HWH NOT WATER HEA PCF POU VINYL COMPOSITE TILE ENLARGED PLAN e ~ li CYD CUBIC YARD ID INSIDE DIAMETER PFL POUNDS PER LINEAL FC)OT UCT ~ ~ REFERENCED SHEET NUMBER DL DEAD LOAD INT INTERIOR PSF POUNDS PER SQUARE FOOT WC WATER CLOSET soo~r ' ~l ;x~ ~t~`'~~~ I ~T~ n~Tnu INV INVERT PSI POUNDS PER SQUARE (INCH WP WATER PROOF (ING) _ l ~ - f DIM DIMENSION JT JOINT PL PROPERTY LINE WWF WELDED WIHE FADHIG DIV DIVISION LAB LABORATORY RA RETURN AIR W WEST DR DOOR LB LAG BOLT RAID RADIUS W WIDTH, WIDE DS DOWN SPOUT LAM LAMINATE (D) REF REFRIGERATOR W/O WITHOUT DWG DRAWING LAV LAVATORY RET RETURN WD WOOD N G0.01 E EAST LH LEFT HAND NORTH ARROW ELEC ELECTRIC LL LIVE LOAD MAT MATERIAL (S) SITE LOCATION MAP MH MANHOLE I _ _ _ ~ v ~ ~jP' DARIN ~ ~p • ~ RANKER • ' ~tv c~,12529 p ~~~oa~ x.]0000 (n~NN ~ Y o Qtr m ~ ~ ~ o Q x ` ~ ~ d LL V E ~ U ~W Z L~ ~o METRO II • 0 o 0 PARKING rn c~ a~ 0 ~ ~ o ~ a ° ~ ~ ~ ~ L a~ U ~ c~ L Q O ¦r PARKING ~ ~ C~ ~ W c ~ ~ ~ ~ CRA Proj. No.: 07107.041 Drawn by, CRHIMK D Checked By: CRH Date: 3/5108 Revisions . ~ • I I \Ij ~ Spa oi ,J Site Plan 1"=50'-4" i CODED DEMOLITION NOTES: ' i it ~ , , „ „ „ , , ' OF REMOVE WALL FOR NEW STOREFRONT ENTRY. SALVAGE CARPET BASE AND ~j DARIN ~p 1 WALLCOUERING TO INFILL EXISTING OPENING, 303 ALIGN 2 SALVAGE EXISTING DOOR FOR REUSE, SERVER ROOM ~ RANKER ; REMOVE ALL CARPET, BASE, CEILING TILE, AND CEILING GRID 3 O O 4 SALVAGE EXISTING SINK FOR REUSE. ~ 3 0 ~ z ? ~ 12529 0 ALIGN A m I ~ I ~ II \ l I ~ ~ ~`°oo E mYoooo ~ 3 ii GENERAL NOTES I 301 304 ' cn ~ N N I I II II I I ~f~;\ WORK ROOM ALIGN WI CORNEA 304 OPEN WORK ~ o ~ v m 3 II II I ~ I~,~ 1, ALLDIMENSIONSSHOWNONTHEDRAWINGSAREFROMINSIDE FACE OF I~______________~I r I ,i~ L-j j11 © ~ ~ i I _ I I I f STUD TO INSIDE FACE OF STUD, UNLESS NOTED OTHERWISE, i ~ I f I ~ I I \ ~ m 9 ~ E ~ I II II I I II i I I I I . I I ~°y~ ~ 2 CONTRACTORSSHALLVEAIFYANDCHECKALLDIMENSIONSAND 1 ' p ~ i I I 4 i i l~ NOTE: CONDITIONS ON THE JOB PRIOR TO COMMENCING WORK, AND SHALL i I ~ i I i i ~ I I - - NOTE: 4 ~ ~ I ~ I I R F EXISTING (1) HR REPORT ANY DISCREPANCIES TO THE ARCHITECT. I i i i i i i I ~ I M~~I i ~ ~ EXISTING (1) HR A1,01 ? l i i i i i ~ RATED WALL, RATED WALL, + PATCHIREPAIR ANY 3. ALL COLUMNS SHALL BE FURRED OUT TO A MINIMUM THICKNESS, TO I I i i I i i i I I I I I PATCHIREPAIR ANY ENSURE THAT THEY ARE PLUMB AND SQUARE. ANY CHANGE OF I I 3 i t i i 3 A l i 3 I I HOLES DUE TO o ~ i a HOLES DUE TO N SPECIFIED DIMENSIONS SHALL BE REPORTED TO THE ARCHITECT, ~ I I i i i i i t i t i i ELECTRICAL ELECTRICAL 9,-2„ `D II II I~ l i I I I I DEMOLITION W NEI II I~ II II II 1 DEMOLITION WI NEW _ 305 ~ ~ ~ 4. NOT USED, I I I i ? I I I I ? n 3 CONSTRUCTION TO l i i MATCH AND MATCH ANDTION TO 300 300 302 Q BREAK AREA MAINTAIN (1) HR AE~ N CONFERENCE ~ 5. UNFINISHED INTERIOR TENANT SEPARATION WALLS SHALL BE INSULATED ~ MAINTAIN (1) HR RATING. AND FINISHED TO MATCH THE SELECTED TENANT FINISHES, U.N.O, ~ RATING. D emo an 6, ALL NEW DOORS SHALL BE BUILDING STANDARD, STAINED AND FINISHED ~ TO MATCH EXISTING, U.N.O. 1 8°-1'_~'~ ~ U 1. DOOR FRAME ROUGH OPENING HEIGHT SHALL BE T-1"FROM THE SLAB ~w TO THE METAL STUD HEADEAFOR T-0"INTERIOR DOORS, U.N.O, ~ ~ ~ 8, ALL LOCKS SHALL BE OF A TYPE WHICH WILL NOT REQUIRE THE USE OF A KEY OA SIMILAR DEVICE TO PERMIT EGRESS, THE LATCHES OR BOLTS New work Ian V ~ Z SHALL BE RETRACTED FROM THE KEEPERS BY THE USE OF A LEVER, WHICH p U ANY PERSON CAN OPERATE WITH REASONABLE EASE AND WITHOUT DOOR SCHEDULE 118~~=1 Lv INSTRUCTION. DOOR FRAME REMARKS 9. REPLACE EXISTING KNOB TYPE HARDWARE WITH A.D.A. APPROVED LEVER Y SIZE ~ TYPE HARDWARE TO MATCH THE BUILDING STANDARD FINISH. ¢ ~ ~ z ~ Q Q ru °C w o ~ ~ o a a ° THK ~ ~ _ WALL TYPES LEGEND NEW PARTITION WALL; 3 518° METAL STUDS @ 2'-0" DEMOLITION NQTES 300 (2)3'-0"z1'-0" 1314" ALUMNSTFRNT ALUMN 3 301A EXISTING 13/4" BLDG. STND. ALUMN EX C~ EXISTING PARTITION WALL TO REMAIN ~ O.C. WITH 518" DRYWALL EACH FACE WITH 1. PERFORM DEMOLITION AS INDICATED ON PLANS AND DETAILS AND C..=.7 EXISTING PARTITION W(FLL TO BE REMOVED ELMiNATOR TRACK TO CEILING HEIGHT, 5EE 31A1.01 I ~ OMPLETION OF THE PROJECT AS INDICATED. 3016 3'-0" z T-0" 1314" BLDG, STND, ALUMN 2 AS REQUIRED FOR THE C 302 EXISTING 1314" BLDG. STND. ALUMN Fx RELOCATED DOOR 2. PROVIDE ADEQUATE TEMPORARY SUPPORT FOR WORK BEING CUT 303 3'-0' z T-0" 1314° BLDG, STND, ALUMN 1 NEW TENANT SEPARATIION WALL; 3 518" METAL ® NEW PARTITION WALL; 3 518" METAL STUDS @ 2'-0" ~ AND PATCHED TO PREVENT FAILURE, DO NOT ENDANGER OTHER 304 (2) 3'-D" z T-0" 1314" ALUMNSTFRNT ALUMN 4 STUDS @ 2'-0" O.C. WITIH SOUND ATTENUATION O.C. WITH 518" DRYWALL EACH FACE, CONSTRUCT ® INSULATION AND 518" DRYWALL E4CH FACE, TO 4"ABOVE FINISH CEILING HEIGHT U.N.O, SEE WORK. PROVIDE ADEQUATE PROTECTION OF OTHER WORK DURING CONSTRUCT TO UNDERSIDE OF DECK ABOVE, 2IA1.01 ~ CUTTING AND PATCHING TO PREVENT DAMAGE. CUT WORK TO BE PERFORMED BY METHODS LEAST LIKELY TO DAMAGE WORK TO BE SEE 11A1,01 ~ RETAINED ANDIORWORKADJOINING, I H IL IMPAIR THE PRODUCT MFGR. SPECIFIED EQUIVALENT PRODUCT 3. DO NOT CUT AND PATCH WORK WH C W L HINGES IVES STANLEY, HALER STRUCTURES LOAD CARRYING CAPACITY OR REDUCE THE LOAD l LOCKSETS SCHLAGE NO SUBSTITUTION DEFLECTION RATIO, CLOSERS LCN 1461 FC DOROMATIC SC71 4. PATCH AND REPAIR ALL REMAINING WALL, FLOOR AND CEILING WITH SARGENT 351 APPROPRIATE MATERIALS COMPATIBLE WITH EXISTING SUBSTRATES OVERHEAD STOPS GLYNN-JOHNSON RIXSON, ABH AND NEW FINISH MATERIALS, FLUSHBOLTS IVES HALER, ROCKWOOD 5. PATCH WITH SEAMS WHICH ARE DURABLE AND AS INVISIBLE AS PUSHIPULLS, STOPS ~ IVES HALER, ROCKWOOD I POSSIBLE, COMPLY WITH SPECIFIED TOLERANCES FOR THE TYPE OF HARDWARE 1 WORK BEING DONE RESTORE EXPOSED FINISHES OF PATCHED AREAS 3 HINGES 5BB14~5X41.5 MATCH AND WHERE NECESSARY, EXTEND NEW FINISH ONTO ADJOINING 1 CLASSROOM LOCK ND70PD BUILDING 2~~ 1'-5112" 6~-~0~~ 1'-5112' 2° 2~~ ~ 2,. RETAINED WORK IN A MANNER WHICH WILL ELIMINATE EVIDENCE OF 1 STOP WS407CCV' STANDARD 6'-0° PATCHING. 24W30 18W30 36W15 V15 6. ANY EQUIPMENT, FIXTURES OR ANY OTHER ITEMS NOT SPECIFICALLY HARDWARE 2 CV CV SHOWN WITH DASHED ONES DESCRIBED HEREIN "TO BE REMOVED" 3 HINGES 5BB14.5X4}.5 MATCH 1 PASSAGE SET ND105 BUILDING REMAIN AND ARE TO BE PROTECTED FROM DAMAGE. NOTIFY OWNER'S 1 STOP WS407CCV STANDARD = ~ ~ ~ ~ ~ E \ IVE ANY ITEMS WHICH MAY INTERFERE WITH 1H REPRESENTAT OF `D u. ~ / \ ~ ID N \ PROGRESS OF THE DEMOLITION WORK BEFORE DISTURBING SA HARDWARE 3 I,~ ITEMS, 6 HINGES 56614,5X4:,5 MATCH S.S. SINK INK ~ TERIAL TO BE REMOVED SHALL 1 CYLINDER - BUILDING 7. UNLESS NOTED OTHERWISE, ALL MA 2 CLOSERS 1461 CUSH FC STANDARD = P.LAM COUNTERTOP BE PROPERLY DISPOSED OF, OR SALVAGED OFF-SITE, BY THE 8400 8"z1" LDW WITH 4 BACK SPL4SH o Irr~nn CONTRACTOR. 2 KICKPLATES 1 POWER SUPPLY PS 873.2 CARDREADERS BY OTHERS 8. ALL ELECTRICAL WORK SHALL CONFORM TO THE NATIONAL 1 ELECTRIC STRIKE 6211 FS 24VDC ~ _ _ ~ ~ ~ I L VJ ~ 0 ELECTRIC CODE, CURRENT EDITION, AND OHIO BUILDING CODE, BALANCE OF HARDWARE BY DOOR SUPPLIER o v 0 ° I. _i 4- CURRENT EDITION. ~ 0 v~ 0\~~ ~ ~ ~ ~ 9. ELECTRICAL CONTRACTOR SHALL TESTALL WIRING FOR CONTINUITY HARDWARE 4 ° M AND GROUNDS BEFORE FIXTURE INSTALLATION AND SHALL THEN TEST 6 HINGES 5BB14.5X4.5 MATCH ° THE ENTIRE SYSTEM IN THE PRESENCE OF THE ARCHITECT OR 2 BALL CATCH ~ ND105 BUILDING BUILDING MANAGER UPON COMPLETION TO ENSURE THE ABSENCE OF i SGL DUMNIY TRIM STANDARD / / ~ L. SHORT CIRCUITS AND GROUNDS. 2 DUMMY HANDLES FRIDGE 18D636 36SB36 N ~i \ U B36 ~ (l~ 2 OVERHEAD HOLDERS 8Y TENANT 10. ALL ELECTRIC TO BE REMOVED BACK TO PANEL; RE-WIRE REMAINING OUTLETS. 1 ELECTRIC STRIKE 6211 FS 24VDC TEMPERED GLASS 20 MIN FIRELITE Q. ~ 1 POWER SUPPLY PS 813.2 CARDREADERS BY OTHERS GLASSINSERTS ~ ~ Q BALANCE OF HARDWARE BY DOOR SUPPLIER break room counter 31a° B doors 304 C doors 300 ~ ~ ~ 318" =1'~0' 318" =1'-0" ! 318" =1'-0" ~ «J ~ ~ ~ IS') ~ • EXISTING DECK EXISTING DECK CRA Proj. No.: 07107.041 PACK FLUTES SOLID Drawn by, CRH/MK WITH INSULATION Checked By: CRH ' AT DECK Date: 3/5108 o METAL STUD Revisions BRACING TO DECK OUS I ! ACOUSTICAL LAY-IN FULL THICKNESS AC TC AS NEEDED CEILING & I SOUND ATTENUATION CEILING & GRID ~ TI SYSTEM GATT INSULA ON 4~~ NOTE; SYSTEM I TRAVEL DISTANCE FOR VACANT ADJACENT SPACE =71'-9" 518" DRYWALL I~ ACOUSTICAL LAY-IN ACOUSTICAL LAY-IN 518 DRYWALL ? ® P CEILING & GRID CEILING & GRID SYSTEM SYSTEM 3 518" METAL STUDS 1'-0" I' r - J @ 2'-0" O.C. 518" DRYWALL r'-------J ? ? 24°" P.LAM o ~ COUNTERTOP . 3 518" METAL STUDS 4 II @ 2'-0 O.C. 3 518 METAL STUDS BASE; SEE • • BASE; SEE FINISH ~ nn^^r A^ n n~-n nr i-~.,~,.,~,~.. BASE; SEE FI1\115H BASE; SEE FINISH FINISH FLOOR; SEE srt~ir t H Jrtt,lr t,H U V ~ Dnfi~C H~ ~ SPECIFICATION .Y SPECIFICATION FINISH SPECIFICATION FINISH FLOOR; SEE FINISH FLOOR; SEE REQUIRED) ZV G FINISH SPECIFICATION FINISH SPECIFICATION 3 518" MTL. STUDS co W15/8" DRYWALL AREA OF~WORK tenant se aratiion wall artition wall artition wall p p p N.T.S. N.T.S. 4 partition wall N.T.SAl mOl N.T.S. third floor I<e plan . i i it ~ I P~E•~•~y ~j,.• DARIN '•~0 • 303 ,J, • 0 SERVER ROOM ' ~ ~ Rp,NKER ~ O UCT-1, B-1, P-1, CLG-1 • 0 0 0 0 0 ~ ? G'j 12529 ~ Sj*~.p,;~~ a ~ 1~` ~ 0 0 0 0 o C 0 0 "DWHEA ERTOU DERSIDE 0 ~~~ooa a.~aoo 0 301 304 x~~NN WORK ROOM OPEN WORK ~ o ~ 0 C-1, B-1, P-1, CLG-1 ~ c 0 0 0 0 0 0 C-2, B-1, P-1, CLG-1 ~ ~ ~ ~ ° 9 E 0 PL-1 ~ ~ ii ~ ~ 0 ? ~ 0 0 0 I~ PL-1 I~ I T o a o I PL-1 ~ 305 300 CONFERENCE BREAKAREA ~ ? 0 0 0 0 0 0 0 RECEPTION C-1, B-1, P-1, CLG-1 C~2, B-1, P-1, CLG-1 C-1, 8.1, P-1, CLG-1 ~ U 0 ~w ~ ~ ~ e ec a cep in an New finish Ian ~ Z p ? 118~~=1~_~~~ 1j8~~_1~_0~~ Ly ' REFLECTED CEILING LEGEND NEW ACOUSTICAL CEILING & GRID SYSTEM @ 8'-10" A.F.F. FINISH SPECIFICATIONS ~ ' Key Item Specification 0 0 RECESSED 2X~ FLUORESCENT LIGHT FIXTURE C-1 CARPET CAMBRIDGE COMMERCIAL CARPET SECTOR SCT53 C-2 CARPET CAMBRIDGE COMMERCIAL CARPET EQUITY DEED #EQU03 Q UCT-1 VINYL COMPOSITION TILE ARMSTRONG STANDARD EXCELON COLOR TBD C B-1 BASE JOHNSONITE 4"COVE BASE COLOR TBD ~ ' ~ P-1 PAINT SHERWIN WILLIAMS EGSHELL FINISH COLOR TBD P-2 PAINT SHERWIN WILLIAMS EGSHELL FINISH COLOR TBD CLG-1 CEILING BUILDING STANDARD ' PL-1 PL4STIC !LAMINATE STYLE AND COLOR TBD_. ' CABINET`S TBS I~~ O DOORS, HARDWARE AND BLINDS to be BUILDING STANDARD ' ~ ' L i i! ~ ~ N INTERIOR FINISH REQUIREMENTS ~ ~ ~ U INTERIOR FINISH OF WALLS AND CEILINGS SHALL HAVE AFLAME-SPREAD AND SMOKE O ~ ~ DEVELOPED RATING NOT GREATER THAT THAT LISTED BELOW AS TESTED IN ~ ~ ~ ACCORDANCE WITH ASTM E 84. THE CLASSIFICATIONS OFINTERIOR FINISHES 0 CORRESPOND TO THE FOLLOWING: ~ ~ ~ ~ i- CLASS A: FLAME SPREAD 0.25; SMOKE DEVELOPED 0-450 I ~ ~ ~ CLASS B; FLAME SPREAD 26.75; SMOKE DEVELOPED D-45D .CLASS C, FLAME SPREAD 76-200; SMOKE DEVELOPED D-45D I C L,O N ~ In TYPE OF SPACE MIN CLASS AEQ'D I' I"' ~ VERTICAL EXITS AND EXIT PASSAGEWAYS A ' EXIT ACCESS CORRIDORS AND OTHER EXITWAYS B ~ ~ ROOMS AND ENCL05ED SPACES C CRA Proj, No.. 07107.041 FLOOR FINISHES THATARE FIBER BASED, SUCH AS CARPET, SHALL CONFOiRM TO Drawn by, CRHJMK CLASSIFICATIONS ASTESTED INACCORDANCE WITN NFPA 253, THE CLASSIFICATIONS ARE AS FOLLOWS; CLASS I, 0,45 WATTS~CM2 OR CREATED; CLASS II, 022 W~,TTSICM2 OR Checked By: CRH GREATER. FINISHED FLOOR MATERIALS OF WOOD, VINYL, LINOLEUM, TER~AZZO AND Date: 3/5108 OTHER RESILIENT FLOOR COVERINGS ARE EXEMPT FROM THESE REQUIREMENTS. Revisions TYPE OF SPACE MIN CLASS REQ'D VERTICAL EXITS, EXIT PASSAGEWAYS AND II EXIT ACCESS CORRIDORS ALL OTHER AREAS DOC FF-1 "PILL TESTui I' i I, ~ • 1 1 Al m02 I 0 Na ~~N ~ i PLUMBING FIXTURE & ROUGH-IN SCHEDULE GENERAL NOTES ~ ~ i W ~ w f ~ aQ ~ m~coooE UMBING CONTRACTOR TO FURNISH INSTALL, PROVIDE ROUGH-IN AND FINAL CONNECTIONS FOR ALL FIXTURES AND EQUIPMENT SHOWN ON THIS SCHEDULE. A.- P.C. SHALL VISIT SITE AND FIELD VERIFY LOCATION AND ROUTING OF EXISTING PL DOMESTIC HOT AND COLD PIPING, VENT PIPING AND SANITARY PIPING BEFORE '2 ro°~oooo !V Q a= a I r U COORDINATE AND VERIFY LOCATIONS OF EQUIPMENT WITH ARCHITECTURAL AND PLUMBING DRAWINGS BEFORE INSTALLATION OF ANY FIXTURES, EQUIPMENT OR PIPING. STARTING ANY WORK. Yd w ~ ~ x(n NAY * SUPPLY WASTE & VENT COMPD& TAG MANUFACTURER MODEL # ITEM 1W(85') HW CW OUTLET TRAP SAFE G AQ~ ~S VENT SERVICES WASTE > o Oar ~ PROF 3 5 ~ ~ iv O 9 ~ [X0 i gi - - EXISTING SINGLE BOWL SS SINK RELOCATED - 1/2" 1/2" 1-1/2" 1-1/2" - 2" 1-1/2" , PLAN NOTES 0 ~ ~d~L U 1.- EXISTING SINGLE BOWL STAINLESS STEEL SINK AND ALL ASSOCIATED TRIM AND O 0 ~ O O REQUIRED COMPONENTS & SERVICES ACCESSORIES TO BE RELOCATED AND REUSED. STORE AND PROTECT DURING CONSTRUCTION TO ALLOW INSTALLATION IN NEW CONSTRUCTION. REMOVE DRAIN PIPING BACK TO MAIN OR STACK AND CAP GASTIGHT, PATCH FLO R TO MATCH ADJACENT ~ ~ 1. FAUCET: EXISTING TO BE RELOCATED AND REUSED. NOTE: CLEAN SINK AND ALL ACCOCIATED TRIM AND ACCESSORIES TO LIKE NEW SURFACES. O M d' ~ a CONDITION. 2.- DISCONNECT AND REMOVE EXISTING EXISTING VENT AND SUPPLY PIPING TO LOCATION INDICATED ON PLAN. PROTECT ENDS OF REMAINING PIPING DURING O CONSTRUCTION TO ALLOW CONNECTION TO NEW CONSTRUCTION. ~ ® V ~ ~ - O a * SEE SPECIFICATIONS FOR EQUIVALENT MANUFACTURERS. REFER TO STACK DIAGRAMS FOR SIZE. 3,- EXISTING SINK RELOCATED BY P.C. PROVIDE ROUGH-IN AND FINAL CONNECTIONS 1 ~ FOR 1-1/2" SAN, 1/2" HW & 1/2" CW. C 5 '111 V A 4) ~ 4,- CONNECT NEW 1-1/2" SAN, 1-1/2" VENT, 1/2" CW & 1/2" HW TO EXISTING. VERIFY EXACT SIZE AND LOCATION OF EXISTING IN FEILD PRIOR TO CONSTRUCTION. PLUMBING SPECIFICATIONS 5,- REMOVE EXISTING SINK AND TRIM, HOT AND COLD WATER LINES AS WELL AS ~U a ? b SANITARY AND VENT PIPING BACK TO MAINS AND CAP WATER TIGHT. 1,- A COMPLETE PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND AS SPECIFIED b. INSPECT EACH INSTALLED UNIT FOR DAMAGE TO FINISH. IF FEASIBLE, RESTORE AND 3 I 111; ~ ~ o ~ W HEREIN, WORK INCLUDES, BUT IS NOT NECESSARILY LIMITED TO THE FOLLOWING PRINCIPAL MATCH FINISH TO ORIGINAL AT SITE; OTHERWISE REMOVE FIXTURE AND REPLACE WITH NEW CATEGORIES. UNIT. FEASIBILITY AND MATCH TO BE JUDGED BY ARCHITECTURAL/ENGINEER. REMOVE ~ ~ ~ ~ C~ a. PLUMBING FIXTURES AND ASSOCIATED TRIM. CRACKED OR DENTED UNITS AND REPLACE WITH NEW UNITS. b. ROUGH-IN, COMPLETE INSTALLATION AND FINAL CONNECTIONS TO PLUMBING FIXTURES. ~ - - S 5 - DUSTING AND CLEANING L'J c. DOMESTIC WATER PIPING SYSTEM . 1 AD ~ W ~N V d. BUILDING SANITARY DRAIN, WASTE AND VENT PIPING. a. CLEAN PLUMBING FIXTURES, TRIM AND STRAINERS OF DIRT AND DEBRIS UPON LEGEND COMPLETION OF INSTALLATION. ~ ~-CW(E) - - ~ M ~ Z ~o 2.- OBTAIN AND PAY FOR ALL PERMITS. UPON COMPLETION, PROVIDE CERTIFICATES OF b. ADJUST WATER PRESSURE AT DRINKING FOUNTAINS, FAUCETS, SHOWER FLUSH VALVES INSPECTION FROM ALL APPROPRIATE LOCAL GOVERNING AUTHORITIES. TO PROVIDE PROPER FLOW STREAM AND SPECIFIED GPM. SAN SANITARY ABOVE FLOOR c. ADJUST OR REPLACE WASHERS TO PREVENT LEAIKS AT FAUCETS AND STOPS. 3~ 3.- DURING THE BIDDING PERIOD, INSPECT THE SITE AND PREMISES OF PROPOSED WORK. ----SAN---- SANITARY BELOW FLOOR REPORT IMMEDIATELY ANY SIGNIFICANT OBSERVED DISCREPANCIES AS RELATED TO THE 16.- CONDUCT A FINAL INSPECTION OF FIXTURES. EXAMINE ROUGHING-IN WORK OF ~ ~ o I) ~ ~ Q z PLANS OR REQUIRED WORK. DOMESTIC WATER AND WASTE PIPING SYSTEMS TO VERIFY ACTUAL LOCATIONS OF PIPING --------V-------- SANITARY VENT ? ? a W CONNECTIONS PRIOR TO INSTALLING FIXTURES. ALSO EXAMINE FLOORS AND SUBSTRATES 4.- WHERE TRADE NAMES, BRANDS OR MANUFACTURERS ARE LISTED, ANY ONE OF THE AND CONDITIONS UNDER WHICH FIXTURE WORK IS TO BE ACCOMPLISHED. CORRECT ANY DOMESTIC COLD WATER SEVERAL NAMED ARE CONSIDERED EQUALLY ACCEPTABLE. NO UNNAMED PRODUCT OR INCORRECT LOCATIONS OF PIPING AND OTHER UNSATISFACTORY CONDITIONS FOR MATERIAL SHALL BE USED UNLESS IT IS LISTED AS A SUBSTITUTE DURING BIDDING, WITH INSTALLATION OF PLUMBING FIXTURES. DO NOT PROCEIED WITH WORK UNTIL UNSATISFACTORY DOMESTIC HOT WATER STATED CHANGE IN COST AND APPROVED IN WRITING BY THE ARCHITECT OR ENGINEER CONDITIONS HAVE BEEN CORRECTED IN A MANNER ACCEPTABLE TO THE INSTALLER. PRIOR TO PLACEMENT OF ORDERS. SUBMIT SHOP DRAWINGS ON ALL FIXTURES, EQUIPMENT DOMESTIC HOT WATER RETURN AND MATERIALS INCLUDING, BUT NOT LIMITED T0: 17.- WASTE AND DRAIN PIPING SHALL BE SCHEDULE ~40 PVC, UNLESS OTHERWISE NOTED a. VALVES IN CONTRACT DOCUMENTS. ALTERNATE PIPING MATERIALS ARE ACCEPTABLE AS A -+~-~-~c-~t-(R)-H--x-~-~-- PIPING TO BE REMOVED b. PIPES, INCLUDING INSULATION AND FIRESTOPPING SUBSTITUTION WHEN THEIR USE IS PERMITTED BY THE LOCAL CODES AND BUILDING c, HANGERS, INCLUDING BUILDING ATTACHMENTS AND INSULATION SHIELDS DEPARTMENT OFFICIALS AND DOES NOT AFFECT OTHER TRADES, SUBSTITUTIONS MUST BE SAN(E) EXISTING SANITARY ABOVE FLOOR d. FIXTURES, INCLUDING TRIM, CARRIERS AND ACCESSORIES LISTED AND QUALIFIED IN BID. e. CLE4NOUTS, FLOOR DRAINS, TRAP PRIMERS, WALL HYDRANTS AND VENT FLASHING a) ALL EXPOSED SOIL, WASTE AND VENT PIPING IN UNFINISHED ROOMS SIMILAR TO - - -SAN(E)- - - EXISTING SANITARY BELOW FLOOR MECHANICAL EQUIPMENT AND STORAGE ROOMS SHALL BE CAST IRON. 0 5.- WORKMANSHIP SHALL BE FIRST CLASS. THE ARCHITECT'S JUDGEMENT SHALL PREVAIL IF b) SOIL, WASTE AND VENT PIPING CONCEALED IN MAISONRY WALLS SHALL BE CAST IRON -------V(E)------- EXISTING SANITARY UENT THE QUALITY IS SUSPECT. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH OR PVC. STATE AND LOCAL BUILDING CODES. c) SOIL, WASTE AND VENT PIPING CONCEALED IN GYPSUM BOARD WALLS AND CHASES -----CW(E)--- EXISTING DOMESTIC COLD WATER c 6,- PROTECT MATERIALS AND EQUIPMENT AFTER DELIVERY TO THE JOB SITE. RESPECT SHALL BE CAST IRON OR PVC. T TO RETECTING THEIR WORK AND TO AVOID CONSTRUCTION d) VENT PIPING IN MASONRY CHASES SHALL BE CAST IRON OR PVC. WHEN PVC IS USED -HW(E)---- EXISTING DOMESTIC HOT WATER OTHER TRADES AS RELA ED P THIS CONTRACTOR SHALL PROVIDE CONCRETE OR TYPE "X" GYPSUM BOARD CAP ~ INTERFERENCES, CALL ATTENTION TO PROBLEMS RELATING TO SPACE REQUIREMENTS SO SEPARATING CHASE FROM AIR PLENUM. -----HWR(E)----- EXISTING DOMESTIC HOT WATER RETURN EARLY RESOLUTION MAY BE OBTAINED, RESPECT THE OWNER'S PROPERTY AT ALL TIMES, e SOIL, WASTE AND VENT PIPING IN RETURN AIR PLENUM SHALL BE CAST IRON. ~ PLUMBING DEMOILITION PLAN 7.- CUT AND PATCH TO INSTALL WORK WHERE FAILURE TO INSTALL SLEEVES OCCURS, OR f) BELOW GRADE (OR SLAB) PIPING AND FITTINGS FOR INTERIOR DRAINAGE SHALL BE t BALL VALVE PAY OTHERS TO PERFORM SUCH WORK. THIS PLUMBING CONTRACTOR SHALL BE SERVICE WEIGHT HUB AND SPIGOT CAST IRON ORI PVC WITH CEMENTED JOINTS. PVC SCALE: 1/8"=1'-0" NORTH RESPONSIBLE TO PERFORM ALL OF HIS OWN CUTTING AND PATCHING OF FLOORS, WALLS DWV PIPING SHALL NOT BE USED FOR SANITARY PIPING UPSTREAM OF GREASE 2 PIPE-FLOOR PENETRATION (2ND FL) AND OUTDOOR SURFACES WHERE NECESSARY TO INSTALL PLUMBING EQUIPMENT. CONCRETE INTERCEPTOR OR FOR BRANCHES SERVING KITCHEN. RILL D. WC1 FIXTURE SERVED ON FLOOR ABOVE SHALL BE SAW CUT, NEATLY AND ACCURATELY. NECESSARY HOLES SHALL BE CORED E 18.- THE PLUMBING CONTRACTOR SHALL INSTALL DRAiINS, CLEANOUTS AND DRAINAGE I PATCHING SHALL BE DONE TO MATCH BOTH THICKNESS AND FINISH OF EXISTING ADJACENT SPECIALTIES. A.F.F. ABOVE FINISHED FLOOR MATERIAL. GENERAL CONTRACTOR SHALL DO ALL PATCHING WORK PAID FOR BY THE PLUMBING CONTRACTOR. ALL FIRE WALL PENETRATIONS SHALL BE FIRE STOPPED WITH 19.- FLOOR DRAINS AND FLOOR CLEANOUT CATALOG MIUMBERS ARE LISTED ON CONTRACT D.S. DOWNSPOUT MATERIALS APPROVED FOR ACTUAL CONDITIONS. DRAWINGS AND ARE BASED ON ZURN, THE SAME TYPE; PRODUCTS IN ALL ASPECTS AS I j 8,- PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL PLUMBING FIXTURES. MANUFACTURED BY WADE, JOSAM, J.R. SMITH OR ANCON MAY BE FURNISHED AT THE DSN DOWNSPOUT OUTLET NOZZLE FIXTURES SHALL BE FURNISHED FREE OF DEFECTS AND SET IN A NEAT, FINISHED AND CONTRACTOR'S OPTION. UNIFORM MANNER. E.C. ELECTRICAL CONTRACTOR 20.- FURNISH AND INSTALL WITH EACH FLOOR DRAIN A CAST IRON P-TRAP. PROVIDE TRAP 9.- PROVIDE FACTORY FABRICATED FIXTURES OF TYPE, STYLE AND MATERIAL INDICATED. FOR PRIMER CONNECTIONS AS AND WHERE INDICATED ON THE CONTRACT DRAWINGS AND EXG EXISTING EACH TYPE FIXTURE PROVIDE FIXTURE AND MANUFACTURER'S STANDARD TRIM. CARRIER, CONNECT TO COLD WATER PIPING. SEATS AND VALVES AS INDICATED BY THEIR PUBLISHED PRODUCT INFORMATION; EITHER AS G.C. GENERAL CONTRACTOR DESIGNED AND CONSTRUCTED, OR AS RECOMMENCED BY MANUFACTURER, AND AS REQUIRED 21.- PROVIDE MEMBRANE CLAMPS ON ALL FLOOR DR~,INS AND CLEANOUTS IN FLOORS FOR A COMPLETE INSTALLATION. ALL FIXTURES OF SAME TYPE MUST BE FURNISHED BY HAVING WATERPROOF MEMBRANE, H.C. HVAC CONTRACTOR SINGLE MANUFACTURER. 22.- THIS CONTRACTOR SHALL BE RESPONSIBLE FOR HAVING ALL DRAINS AND CLEANOUTS K.E.C. KITCHEN EQUIPMENT CONTRACTOR O ~ 10.- REFER TO PLUMBING FIXTURE EQUIPMENT AND ROUGH-IN SCHEDULE ON THE FLUSH AND LEVEL WITH FINISH FLOOR OR WALL, COOfdDINATE ELEVATIONS WITH GENERAL CONTRACT DRAWINGS FOR FIXTURE MODEL NUMBERS, REQUIRED ACCESSORIES AND SERVICES CONTRACTOR. ALL CLFANOUTS AND DRAINS ARE NOT LEVEL WITH FLOOR OR FLUSH WITH O,p,C. OHIO PLUMBING CODE AND ROUGH-IN PIPE SIZES, WALLS SHALL BE REMOVED AND REPLACED TO THE SAUISFACTION OF THE ARCHITECT. 23.- CLEANOUTS SHALL BE INSTALLED AS FOLLOWS: RD ROOF DRAIN 11.- PLUMBING FITTINGS, TRIM AND ACCESSORIES a. AT EACH CHANGE IN DIRECTION OF PIPING GREATER THAN 45 DEGREES. a. FITTINGS, TRIM AND ACCESSORIES: WHERE THEY ARE EXPOSED OR SEMI-EXPOSED, S.S. SANITARY STACK ~ ~ PROVIDE BRIGHT CHROME-PLATED OR POLISHED STAINLESS STEEL UNITS. PROVIDE COPPER b. AT MINIMUM INTERVALS OF 50 FT. FOR PIPING 4~" AND SMALLER AND 100 FT. FOR OR BRASS WHERE NOT EXPOSED, LARGER PIPING. STD STANDARD 0 b. WATER OUTLETS: AT LOCATIONS WHERE WATER IS SUPPLIED (BY MANUAL, AUTOMATIC 24.- PLUMBING CONTRACTOR SHALL FURNISH AND IN~iTALL TRAP PRIMER VALVES ON COLD ~ ~ OR REMOTE CONTROL), PROVIDE COMMERCIAL QUALITY FAUCETS, VALVES OR DISPENSING WATER PIPING FOR CONNECTION FLOOR DRAIN TRAPS .AS REQUIRED. ~ TEMPERED WATER DEVICES OF TYPE AND SIZE INDICATED AND AS REQUIRED TO OPERATE AS INDICATED. a. TRAP PRIMER VALVES SHALL BE AS MANUFACTURED BY PRECISION PLUMBING ~ O INCLUDE MANUAL SHUT OFF VALVES AND CONNECTING STEM PIPES TO PERMIT OUTLET PRODUCTS WITH 1/2" COPPER LINE TO FLOOR DRAIN. TRAP PRIMER VALVES SHALL V.S, VENT STACK SERVICING WITHOUT SHUT DOWN OR WATER SUPPLY PIPING SYSTEMS. CONFORM TO ASSE STANDARD N0. 1018. c. P-TRAPS: INCLUDE REMOVABLE P-TRAPS WHERE DRAINS ARE INDICATED FOR DIRECT b. TRAP PRIMERS OF THE SAME TYPE AS MANUFACTURED BY E&S OR WATTS MAY BE V.R. VENT RISER 304 ~ ~ ~ CONNECTION TO DRAINAGE SYSTEM. FURNISHED AT CONTRACTOR'S OPTION. d. CARRIERS: PROVIDE CAST IRON SUPPORTS FOR FIXTURES Of EITHER GRAPHITIC GRAY VTR VENT THRU ROOF O SERVER ROOM N L U IRON, DUCTILE IRON OR MALLEABLE IRON AS INDICATED, c. INSTALL TRAP PRIMER VALVES IN ACCORDANCE WITH MANUFACTURER'S 0 > ~ RECOMMENDATIONS. O e. FIXTURE BOLT CAPS; PROVIDE MANUFACTURE'S STANDARD EXPOSED FIXTURE BOLT OD STACK SYMBOL CAPS FINISHED TO MATCH FIXTURE FINISH. o ~ o~ f. ESCUTCHEONS: WHERE FIXTURES SUPPLIES AND DRAINS PENETRATE WALLS AND 25.- PROVIDE PIPES AND PIPE FITTINGS FOR DOMESTIC WATER PIPING SYSTEM AS LISTED ~ FLOORS IN EXPOSED LOCATIONS, PROVIDE CHROME PLATED CAST BRASS ESCUTCHEONS WITH BELOW: CONNECT TO EXISTING O „ e SET SCREW. a. INTERIOR OVERHEAD WATER PIPING: PIPE SIZE 2 AND SMALLER. TYPE 'L SEAMLESS L a ~ g. AERATORS: PROVIDE AERATORS OF TYPES APPROVED BY HEALTH DEPARTMENT HAVING HARD DRAWN COPPER TUBING. JURISDICTION, b. INTERIOR UNDER FLOOR WATER PIPING: ALL SIZES: TYPE "K" WITH MINIMUM NUMBER O o ~ ~ ~ a~ V ~ ~ ~ ( OF WROUGHT COPPER SOLDER TYPE FITTINGS ENCASED IN A TILE OR PLASTIC PIPE SLEEVE. 12.- VITREOUS CHINA TOILET ROOM FIXTURES AND CATALOG NUMBERS ARE LISTED ON ALL JOINTS IN UNDERGROUND LINES SHALL BE MADE WITH "SILFOS"). ~ CONTRACT DRAWINGS AND ARE BASED ON AMERICAN STANDARD. FIXTURES EQUAL IN ALL c, INSULATE DOMESTIC HOT AND COLD WATER PIPING WITH FIBERGLASS PIPE INSULATION, <; ASPECTS AS MANUFACTURED BY KOHLER, ELDER OR CRANE MAY BE FURNISHED AT THE PROVIDE ALL-SERVICE JACKET. ` C ~ L 301 304 I, ~ ~ ~ CONTRACTORS OPTION. SUPPLIES, STOPS AND WASTE FITTINGS LISTED ARE BASED ON d. INSULATION THICKNESS FOR DOMESTIC COLD WATER, HOT WATER AND HOT WATER ~ MCGUIRE, EQUALS WHICH MAY BE FURNISHED AT THE CONTRACTOR'S OPTION ARE E.B.C. CIRCULATING PIPING: 1" THICK FOR PIPING 1-1/4" AND LARGER, 1/2" THICK FOR PIPING I V.~ 1-1/2 ~ WORK ROOM OPEN WORK AND CHICAGO. SEATS LISTED FOR WATER CLOSETS ARE BASED ON OLSONITE. EQUALS WHICH 1" AND SMALLER. 1_1/2"~~ S1 ` MAY BE FURNISHED AT THE CONTRACTOR'S OPTION ARE KOHLER, CENTOCO, BEMS OR e. INSULATION THICKNESS FOR DOMESTIC HOT WATER PIPING WITH TEMPERATURE I ` SPERZEL. ALL COUNTER TOP MOUNTED LAVATORIES SHALL BE SELF-RIMMING. MAINTENANCE HEAT TRACING CABLE; 2" THICK FOR PIPING 2-1/2" AND LARGER, 1-1/2" ~ I~ • ~ THICK FOR PIPING 1-1/4" - 2", 1" THICK FOR PIPING 1" AND SMALLER. E~' a 13.- INSTALLATION OF PLUMBING FIXTURES f. INSULATION ON PIPING 1-1 4" AND SMALLER SHALIL BE OVERSIZED ONE PIPE SIZE TO a. INSTALL PLUMBING FIXTURES OF TYPES INDICATED WHERE SHOWN AND AT INDICATED / 3 3 I CRA Proj. Na.: 07107.041 HEIGHTS; IN ACCORDANCE WITH FIXTURE MANUFACTURER'S WRITTEN INSTRUCTION, ALLOW HEAT TRACEING CABLE. ~ ROUGHING-IN DRAWINGS AND WITH RECOGNIZED INDUSTRY PRACTICES. ENSURE THAT 26.- AT THE CONTRACTOR'S OPTION, MECHANICALLY FORMED TEE CONNECTION UTILIZING Drawn by, BJB 1-1/2 ~ S1 PLUMBING FIXTURES COMPLY WITH REQUIREMENTS AND SERVE INTENDED PURPOSES. THE T-DRILL TUBE BRANCHING SYSTEM MAY BE USED FOR DOMESTIC WATER PIPING SAN Checked By, BJV COMPLY WITH APPLICABLE REQUIREMENTS OF THE NATIONAL PLUMBING CODE PERTAINING TO SYSTEMS. ~ ~ 1 INSTALLATION OF PLUMBING FIXTURES. a. MECHANICALLY EXTRACTED COLLARS SHALL BE F(DRMED IN A CONTINUOUS OPERATION ~/2„ /~I--~ 1-1/2" Date; 3/3108 b. FASTEN PLUMBING FIXTURES SECURELY TO INDICATED SUPPORTS OR BUILDING CONSISTING OF DRILLING A PILOT HOLE N OU U _ "J CO CONSTRUCTION AND ENSURE THAT FIXTURES ARE LEVEL AND PLUMB. SECURE PLUMBING A D DRAWING T THE T BE SURFACE TO FORMA 1 1/2 - SUPPLIES BEHIND OR WITHIN WALL CONSTRUCTION SO AS TO BE RIGID AND NOT SUBJECT COLLAR HAVING A HEIGHT OF NOT LESS THAN THREE TIMES THE THICKNESS OF THE TUBE ~~~~w(Ej ~ Revisions I TO PULL OR PUSH MOVEMENT. WALL. THE COLLARING DEVICE SHALL BE FULLY ADJUSTABLE AS TO INSURE PROPER TOLERANCE AND COMPLETE UNIFORMITY OF THE JOINT., (E1 c, PROTECT INSTALLED FIXTURES FROM DAMAGE DURING THE REMAINDER Of THE b. THE JOINING BRANCH TUBE SHALL BE NOTCHED AND DIMPLED IN A SINGLE PROCESS ~ 3 i 300 CONSTRUCTION PERIOD. SO AS TO SET THE PROPER PENETRATION OF THE BRANCH TUBE INTO THE FITTING TO ~ L/ 3D5 I ASSURE A FREE FLOW JOINT. RECEPTI 14.- FIELD QUALITY CONTROL c, ALL JOINTS SHALL BE BRAZED IN ACCORDANCE (WITH COPPER DEVELOPMENT RECEPTION ERENCE 4 BREAKAREA a, UPON COMPLETION OF INSTALLATION OF PLUMBING FIXTURES AND AFTER UNITS ARE ASSOCIATION COPPER TUBE HANDBOOK USING B-CUP SERIES FILLER METAL. NOTE: WATER PRESSURIZED, TEST FIXTURES TO DEMONSTRATE CAPABILITY AND COMPLIANCE WITH SOLDERED JOINTS WILL NOT BE PERMITTED. REQUIREMENTS. WHEN POSSIBLE, CORRECT MALFUNCTIONING UNITS AT SITE, THEN RETEST d. ALL MECHANICALLY FORMED BRANCH COLLARS SHIALL BE APPROVED BY THE NATIONAL STACK DIAGRAM TO DEMONSTRATE COMPLIANCE; OTHERWISE REMOVE AND REPLACE WITH NEW UNITS AND STANDARD PLUMBING CODE, B.O.C.A., I.A.P.M.O., S.B.C.iC. PROCEED WITH RETESTING. No SCALE I 7 i, ~ • I 111 1 IAA~'f11?1n 1"11 A AI ~ ® ~ rL.uiviDuvu ri.-All I -l SCALE: 1/8"=l'-O" NORTH i MECHANICAL SPECIFICATIONS P.C. PLUMBING CONTRACTOR H.C, HEATING CONTRACTOR 1.- A COMPLETE HEATING, VENTILATING AND AIR CONDITIONING SYSTEM AS SHOWN ON 16,- AIR DISTRIBUTION DEVICES ARE SCHEDULED ON THE DRAWINGS. MANUFACTURER 22.- AS EACH AIR DISTRIBUTION SYSTEM IS PUT INTO OPERATION, ALL ITEMS OF 28- GUARANTEE THE DRAWINGS AND AS SPECIFIED HEREIN. WORK INCLUDES, BUT IS NOT NECESSARILY LISTED IN THE SCHEDULE IS INTENDED AS A STANDARD TO SUPPLEMENT THE DEVICE EQUIPMENT INCLUDED THEREIN SHALL BE ADJUSTED TO PERFECT WORKING ORDER. RF a. THIS CONTRACTOR SHALL GUARANTEE ALL WORKMANSHIP, EQUIPMEI ANSHIP, EQUIPMENT AND E.C. ELECTRICAL CONTRACTOR LIMITED T0, THE FOLLOWING PRINCIPAL CATEGORIES: DESCRIPTION. DEVICES EQUAL TO THOSE CATALOG NUMBERS SCHEDULED, AS THIS SHALL INCLUDE BALANCING AIR AND ADJUSTING FAN SPEEDS, BELTS, PULLEYS, MATERIAL ENTERING INTO THIS CONTRACT FOR A PERIOD OF ONE (1) YEAR F ' ONE (1) YEAR FROM THE f PROVING TO BE G.C. GENERAL CONTRACTOR ~p ~~3~/y~~ a. AIR DISTRIBUTION SYSTEM CONSISTING OF SUPPLY, AND EXHAUST DUCTWORK MANUFACTURED BY TITUS, KRUEGER, BARBER COLEMAN OR ANEMOSTAT ARE TIGHTENING PACKING GLANDS, OILING AND ADJUSTING ALL OPERATING EQUIPMENT. DATE OF FINAL ACCEPTANCE, ANY MATERIALS OR EQUIPMENT PROVING TO BE AND ASSOCIATED AIR DISTRIBUTION AND TERMINAL DEVICES. ACCEPTABLE. DEFECTIVE DURING THIS GUARANTEE PERIOD SHALL BE MADE GOOD BY THIS E GOOD BY THIS b, ALTERATION WORK IN THE EXISTING BUILDING. 23.- VERSE THE OWNERS REPRESENTATIVES IN ALL MATTERS PERTAINING TO THE CONTRACTOR WITHOUT EXPENSE TO THE OWNER, 17,- BALANCING DAMPERS, IN ADDITION TO THOSE INCORPORATED IN AIR LISTRIBUTION PROPER OPERATION AND MAINTENANCE OF EQUIPMENT WHICH IS FURNISHED UNDER b. THIS PROVISION IS INTENDED SPECIFICALLY TO COVER DEFICIENCIES I O,A, OUTSIDE AIR ~ o Z ER DEFICIENCIES IN ~ a ~ 2.- OBTAIN AND PAY FOR ALL PERMITS. DEVICES, SHALL BE SINGLE CROSS-BLADE UP TO 12" BLADE WIDTH AND THIS CONTRACT. INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTION PAMPHLETS, CONTRACT COMPLETION OR PERFORMANCE WHICH ARE DISCOVERED AFTER SY R.A, RETURN AIR DVERED AFTER SYSTEMS (L w F J OR VIBRATION PROBLEMS SA, SUPPLY AIR • O ~ N Q • ~ ~ ~ o o ~ MULTI-BLADE IN LARGER SIZES, DAMPERS MOUNTED IN DUCTS SHALL BE CONTROLLED OR BROCHURES AND WARRANTIES, SHALL BE OBTAINED FROM EACH MANUFACTURER ARE PLACED IN OPERATION, PIPE AND DUCT LEAKS, NOISE OR VIBRATION PR 3.- DURING THE BIDDING PERIOD INSPECT THE SITE AND PREMISES OF THE BY A LOCKING QUADRANT POSITIONER WITH HANDLE. FOR DUCTS WITH EXTERIOR OF THE PRINCIPAL ITEMS OF EQUIPMENT, AND THESE SHALL BE TURNED OVER TO WHICH ARE NOTED OR WHICH DEVELOP, REPAIR OR REPLACEMENT OR MOTOF EMENT OR MOTORS AND PROPOSED WORK. REPORT IMMEDIATELY ANY SIGNIFICANT OBSERVED DISCREPANCIES AS INSULATION, PROVIDE SUITABLE EXTENSIONS FOR POSITIONERS EQUAL TO VENT LOCK THE ARCHITECT FORMALLY, IN A LETTER OF TRANSMITTAL, LISTING SPECIFICALLY THE SWITCHES WHICH FAIL, REPLACING PUMP SEALS, FAULTY, FAILING OR NOISY E JLING OR NOISY BEARINGS, EXH EXHAUST AIR ~ ~ o o° a ~ ~ARY ASSISTANCE IN ~ ~ x (n ~ N N QT THERMOSTAT -MOUNTING HEIGHT 48" 6 RELATED TO THE PLANS OR THE REQUIRED WORK, 637. MULTI-BLADE DAMPERS SHALL BE OPPOSED BLADE TYPE WITH ADEQUATE NATURE OF THE MATERIAL BEING TRANSMITTED. THE ARCHITECT WILL TURN THIS DAMAGE DUE TO EXPANSION OR CONTRACTION, SUPPLEMENTARY ASSISTANCE LOCKING MEANS FOR STABLE POSITIONING. FURNISH ACCESS PANELS WHERE REQUIRED MATERIAL OVER TO THE OWNER IN A FORMAL LETTER OF TRANSMITTAL. IN ADDITION, BALANCING, ADJUSTING OR PROVIDING OPERATING INSTRUCTIONS AS A NEED I ONS AS A NEED DEVELOPS ~ ~ ~ O ti ~ ~ WHERE NECESSARY TO H1 EQUIPMENT REFERENCE SYMBOL ~ d m 4.- WHERE TRADE NAMES, BRANDS OR MANUFACTURERS ARE LISTED, ANY ONE OF FOR ACCESS TO DAMPERS. THE CONTRACTOR SHALL PREPARE A CHART LISTING ALL ITEMS OF EQUIPMENT WHICH AND REPLACING OVERLOAD HEATER ELEMENTS IN STARTERS WHERE NECESSAf THE SEVERAL NAMED ARE CONSIDERED EQUALLY ACCEPTABLE. NO UNNAMED PRODUCT ARE FURNISHED UNDER HIS/HER CONTRACT AND INDICATING THE NATURE OF KEEP SYSTEMS IN OPERATION. PROF ~ ~f~a o ~ OR MATERIAL SHALL BE USED. 18.- DUCTWORK STANDARDS MAINTENANCE REQUIRED, THE RECOMMENDED FREQUENCY OF CHECKING THESE POINTS c. THIS PROVISION SHALL NOT BE CONSTRUED TO INCLUDED MAINTENAN a. CONSTRUCTION SHALL BE GALVANIZED SHEET METAL UNLESS OTHERWISE AND THE TYPE OF LUBRICATING MEDIA OR REPLACEMENT MATERIAL REQUIRED. THREE SUCH AS REPLACING FILTERS, TIGHTENING OR REPACKING GLANDS, GREASING, LUDED MAINTENANCE ITEMS 2 NOTE SYMBOL LANDS, GREASING, OILING, ~ p ~ 5-, SUBMIT SHOP DRAWINGS ON MAJOR ITEMS OF EQUIPMENT AND MATERIALS. NOTED OR ALLOWED UNDER ALTERNATE CONSTRUCTION. SMACNA STANDARDS OF (3) SEfS OF OPERATING AND MAINTENANCE INSTRUCTIONS AND WIRING DIAGRAMS BELT TIGHTENING AND CLEANING STRAINERS. 105 ROOM NUMBER SUBMITTALS SHALL INCLUDE MAJOR ITEMS OF HEATING AND COOLING EQUIPMENT AND CONSTRUCTION SHALL GOVERN REGARDING DUCT PRESSURE CLASSIFICATION, METAL SHALL BE FURNISHED ON EACH PIECE OF EQUIPMENT, d. PROVISIONS OF THIS GUARANTEE SHALL BE CONSIDERED SUPPLEMEN ERED SUPPLEMENTARY TO - g -6 APPROXIMATE ELEVATION FROM FLOOR TO BOTTOM OF DUCT, PIPE OR AIR DISTRIBUTION DEVICES. GAUGES, GALVANIZING THICKNESS, CONSTRUCTION DETAILS AND STIFFENERS. GUARANTEE PROVISIONS UNDER GENERAL CONDITIONS. b. NFPA 90 SHALL GOVERN WHERE APPLICABLE. 24.- AFTER ALL EQUIPMENT HAS BEEN ADJUSTED, THE CONTRACTOR SHALL MAKE A e. GUARANTEE PERIOD SHALL BEGIN AT THE TIME OF BENEFICIAL OCCUf BENEFICIAL OCCUPANCY OF EQUIPMENT ITEM E 6.- WORKMANSHIP SHALL BE FIRST CLASS. THE ARCHITECT'S JUDGMENT SHALL c. ELBOWS SHALL HAVE AN INSIDE RADIUS EQUAL TO THE DUCT WIDTH, IN TRIAL RUN AND DEMONSTRATE TO THE ARCHITECT ANO THE OWNER THAT THE THE BUILDING, WHICH SHALL BE A MATTER OF AGREEMENT AND RECORD BET AND RECORD BETWEEN Ht DETAIL REFERENCE SYMBOL, DETAIL "A" SHOWN ON SHEET H1 ~ PREVAIL IF THE QUALITY IS SUSPECT. LIEU OF WHICH DOUBLE WALL TURNING VANES HAVING EQUIVALENT OR LESS REQUIREMENTS OF THE CONTRACT HAVE BEEN FULFILLED. DURING THIS RUN, THE THE ARCHITECT AND THE OWNER. PRESSURE DROP ARE ACCEPTABLE. CONTRACTOR SHALL EXPLAIN TO THE OWNER'S REPRESENTATIVE THE COMPLETE 01-8"D CEILING MOUNTED AIR DEVICE, D1- AIR DEVICE DESIG., REFER TO ~ Y THE LEGAL INSPECTION SCHEDULE. 8"-NECK SIZE, 250-REQUIRED CFM, 3-DESIGNATES 3 WAY ~ ~ 7.- PROTECT MATERIALS AND EQUIPMENT AFTER DELIVERY TO THE JOB SITE. RESPECT d, MATERIALS SHALL MEET ASTM E-84 STANDARDS FOR SMOKE DEVELOPMENT OPERATION OF THE SYSTEM AND THE FUNCTION OF ALL MAJOR ITEMS OF EQUIPMENT. 29.- FURNISH AN {NSPECTION CERTIFICATE OF APPROVAL BY THE LEGAL INSI OTHER TRADES AS RELATED TO PROTECTING THEIR WORK AND TO AVOID OF 150 OR LESS AND FLAME SPREAD OF 25 OR LESS. A PERIOD OF 48 HOURS OF CONTINUOUS TROUBLE-FREE OPERATION ON ALL PARTS DEPARTMENT AS A CONDITION OF FINAL ACCEPTANCE. THROW IF OTHER THAN 4-WAY IBRANCH. DUCT SIZE SAME AS NECK # SIZE UNLESS INDICATED OTHERWISE, "u CONSTRUCTION INTERFERENCES. CALL ATTENTION TO PROBLEMS RELATING TO SPACE OF THE WORK SHALL BE CONSIDERED THE MINIMUM REQUIREMENT TO DEMONSTRATE .C o REQUIREMENTS, SO EARLY RESOLUTION MAY BE OBTAINED. RESPECT OWNER'S 19.- FANS THAT THE SYSTEM IS SATISFACTORY AND MEETS FULLY THE REQUIREMENTS OF THE PROPERTY AT ALL TIMES. THE FOLLOWING LISTS TYPES OF FANS, RELATED CONSTRUCTION FEATURES AND CONTRACT, S1-10"-6" WALL OR DUCT MOUNTED NR DEVICE, Sl AIR DEVICE DESIG., REFER ~ a MANUFACTURERS. ALL FANS OF ANY ONE LIST TYPE SHALL BE OF THE SAME TO SCHEDULE. 10"x6" NECK SIZE, 200-REQUIRED CFM, 1'-6" MOUNTING ~ (/l HEIGHT FROM FLOOR TO BOTTOM OF AIR DEVICE. BRANCH DUCT SIZE ~ ~ ~ ~ ~ V J 8.- CUT AND PATCH TO INSTALL WORK WHERE FAILURE TO INSTALL SLEEVES OCCURS, MANUFACTURER. (COLOR BY ARCHITECT) 25.- AIR BALANCING OR PAY OTHERS TO PERFORM SUCH WORK. a. POWER ROOF VENTILATOR, VERTICAL SHAFT OPEN CENTRIFUGAL WHEEL c, AN AIR BALANCE SHALL BE PERFORMED BY H.C. SAME AS NECK 51ZE UNLESS INIDICATED OTHERWISE, ~1 ~I "V" BELT DRIVE, WITH SPUN ALUMINUM WEATHERPROOF HOUSINIG, b. AS EACH AIR SUPPLY OR EXHAUST SYSTEM IS COMPLETED, IT SHALL BE SET 9.- IN ALTERATION AND REMODELING WORK PERFORM ALL REMOVAL AND RELOCATION RESILIENTLY MOUNTED MOTOR AND MOTOR OPERATED AUTOMATIC BACK IN OPERATION AND THE SYSTEM BALANCED TO DELIVER THE QUANTITIES OF AIR FIRE DAMPER ;;C~~ i Q WORK KINDRED TO THE HVAC WORK. LEAVE ALL EXISTING SYSTEMS CONTINUOUS AND DRAFT DAMPER AND BIRD SCREEN. PENN, GREENHECK, JENN AIIR OR INDICATED (WITHIN PLUS OR MINUS 10%). METHODS, PROCEDURES, EQUIPMENT AND _ o~ ~~U MANUAL BALANCING VOLUME DAf~1PER WITH LOCKING DEVICE ~1'~I ~ ~ W FUNCTIONAL. REMOVE EXTRANEOUS DUCTWORK AND EQUIPMENT, NO REMOVED COOK. FURNISH MOTOR DISCONNECT SWITCH UNDER HOOD. CERTIFICATION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF "NATIONAL MATERNAL SHALL BE REUSED UNLESS EXPRESSLY SHOWN. STANDARDS FOR FIELD MEASUREMENTS AND INSTRUMENTATION, TOTAL SYSTEM 20.- DUCT TYPES AND APPLICATION BALANCE", AS PUBLISHED BY AABC. u c"~ ~~1 ~ ~ 1" DOOR UNDER CUT BY GENEPoAL CONTRACTOR Z ~ ~ 10.- SUPPORT EQUIPMENT AND PIPE HANGERS FROM STRUCTURAL PORTIONS ONLY, THE FOLLOWING LISTS VARIOUS TYPES OF DUCTWORK SYSTEMS INCLUDING APPLICATION c. AIR BALANCE REPORTS SHALL INCLUDE AMPERE RATINGS OF MOTORS. NOT FROM DECKS, AND SPECIFIC CONSTRUCTION REQUIREMENTS: a. TYPE 1A -,LOW PRESSURE DUCTWORK, USED FOR SUPPLY, RETURN, 26,- AS THE TIME OF WORK COMPLETION APPROACHES, THE CONTRACTOR SHALL 11.- PAINT ALL UNPAINTED OR RUSTY SURFACES ON SUPPORTS, HANGERS, PIPING EXHAUST AND GENERAL VENTILATION, SMACNA STANDARDS, 2" S.P. CLASSIFICATION SURVEY AND INSPECT HIS/HER WORK TO CONFIRM THAT IT IS COMPLETE AND DUCT RISE IN DIRECTION OF AIR FLOW ~ ~ T AND EQUIPMENT WITH ONE (1) COAT RUSTOLEUM (COLOR BY ARCHITECTO WHERE THE WITH SEAL CLASS "B". FINISHED. HE/SHE SHALL THEN NOTIFY THE ARCHITECT AND REQUEST THAT A FINAL -p--> DUCT DROP IN DIRECTION OF AIR FLOW W pi • ~ ~ ITEM WILL BE EXPOSED TO VIEW IN ITS FINAL STATE. b, TYPE 6B -FLEXIBLE DUCT LOW PRESSURE INSULATED GENFLEX TYPE IL INSPECTION BE MADE. IT SHALL NOT BE CONSIDERED THE ARCHITECT'S OR FLEXIBLE DUCT CONNECTION ; ~ ~ H FACTORY FINISH HAS DETERIORATED ACOUSTICAL OR WIRE MOLD OR THEMOFL[LX EQUIVALENT, 1" FLEXIBLE FIBROUS GLASS ENGINEER'S OBLIGATION TO PERFORM A FINAL INSPECTION UNTIL THE CONTRACTOR 12.- TOUCHUP OR REFINISH EQUIPMENT W ERE INSULATION WITH ACOUSTICALLY "SOFT" LINER BONDED TO A GALVANIZED SPRING WIRE cn n/ DUE TO EXPOSURE. HELIX AND WITH REINFORCING VAPOR BARRIER JACKET. UL 181 CLASS 1. USE HAS INSPECTED THE WORK AND SO STATES AT THE TIME OF THE REQUEST FOR THE FACTORY FURNISHED END CLAMPING COLLAR AND ADHESIVE. USE FOR CONNECTING FINAL INSPECTION, i ~ AIR TURNING VANES ~ oo L_L_ ~ o opt 13.- PAINT DULL BLACK ALL VISIBLE METAL BEHIND GRILLES AND REGISTERS. LOW PRESSURE SUPPLY DUCTS TO AIR DISTRIBUTION DEVICES WHERE SHOWN. LOW PRESSURE BEL~MOUTH WITFN LOCKING QUADRANT DAMPER Z ~ ~ ~ MAXIMUM 4 FT. LENGTH, 27.- REQUESTS TO THE ARCHITECT OR ENGINEER OR OWNER FOR FINAL INSPECTION 14.- INSULATE ALL DUCTWORK WITH 1" THICK, 3/4 LB. DENSITY FIBROUS GLASS c, ALL LOW PRESSURE DUCTWORK SHALL BE INTERNALLY INSULATED WITH 1" SHALL BE ACCOMPANIED BY A LIMITED LIST OF KNOWN DEFICIENCIES IN COMPLETION, W ~ DUCT WRAP WITH FOIL FACE. INSULATION SHALL MEET 25/50 SMOKE DEVELOPMENT THICK FIBERGLASS DUCT LINER. WITH APPROPRIATE EXPLANATION AND SCHEDULE FOR COMPLETING THESE; THIS IS IN z SUPPLY AND OR OUTSIDE AIR DUCT DROP RATINGS, THE INTEREST OF EXPEDITING ACCEPTANCE FOR BENEFICIAL OCCUPANCY. 21.- COORDINATE DUCT LAYOUT CAREFULLY WITH OTHER TRADES TO AVOID CONFLICT RETURN, EXHAUST AND OR RELIEF A1R DROP 15.- ADHERE INSULATION ON DUCTS WITH NON-ORGANIC HOT OR COLD ADHESIVE WITH STRUCTURAL ELEMENTS, LIGHTING AND PLUMBING-HEATING PIPING. DO NOT HANG APPLIED TO THE BOTTOM SIDE ONLY AND IMPALING PINS, ONE ROW AT 18" CENTER ANY DUCT LINES UNTIL RECENING APPROVAL OF SHEETMETAL DRAWINGS, HAVING FOR ALL DUCTS UP TO 24" WIDE AND TWO OR MORE ROWS ON WIDER DUCTS, DUCTWORK FABRICATED AND DELIVERED IN ADVANCE SHALL NOT BE JUSTIFICATION FOR SUPPLY AND OR OUTSIDE AIR RLSE ~ • • JOINTS SHALL BE TAPED TO OVERLAP FOR VAPOR BARRIER. VAPOR BARRIERS SHALL INTERFERENCE WITH OTHER TRADES, 8E CONTINUOUS TO PREVENT CONDENSATION, SUPPLY AND OR OUTSIDE AIR RISE RETURN, EXHAUST AND OR RELIEF AIR RISE RETURN, EXHAUST AND OR RELIEF AIR RISE OBC VENTILATION AIR RATE AREA OA, CFM EST. MAX, OA. CFM REpUIRED REQUIRED ACTUAL ACTUAL WORK TD BE REMOVED ~ SPACE USAGE OCCUPANCY CLASSIFICATION SUB CLASSIFICATION / / O.A. EXHAUST O.A. EXHAUST NOTES SQ. FT. SQ. FF. OCCUPANTS PERSON CFM CFM CFM CFM .Q BUSINESS OFFICE EXAMS/OFFICE 2365 - 17 20 34D - 786 BUSINESS OFFICE WAITING/CONFERENCE 612 - 16 20 160 - 170 - 1 (E) TOTAL 2997 500 - 956 - NOTES; 1.- REQUIRED OUTSIDE AIR BASED ON ASHRAE STANDARD 62 INTERMITTENT USE, (E) S /~M 7 `•J i i AIR DISTRIBUTION DEVICES i 0?°° ~ i~ CFM 8"D i„ OWBE -OFF WHITE BAKED ENAMEL FINISH ECL - ETCHED CLEAR LACQUER FINISH 100 (E) ~4 ~ 3 CFM ~ ~ TAG DESCRIPTION MODULE SIZE MOUNTING TYPE CONSTRUCTION TYPE FINISH CATALOG NUMBER REQ'D ~ ~ - - ~ ~ R1-10"X22 ~ Q TAY-IN SURFACE ALUM. STEEL O,W,B.E. E,C,L, PRIMER MFR. MODEL ACCESS. 304 0 6 ERVER 00$„D _a_o_o(~~ MGRCUBE ~ ~ ~ ~ R1 EGGCRATE GRILLE 10"x22" • • • TITUS 50F - O oo / CFM` 3 CFM 8x12 O ~ V C R1- "X22" ? _ L ~ A a ~ 4000FM /8 p ~ LOL ~ ~ ~ (5 _ . ® D MGR CUBE ~ ~ ~ ~ 0 8x12 C R1-10"X22" L/ ~ ~ C _ ~ c REQ'D ACCESS. 301 1040CFM ~ ` 304 6000FM ~ / ~ 1. 115 R M W IC + G`~ CFM 8"D ® R1-10"X22" 10"p ~ M RCUBE 8°D 3 54 0/1 L/ ~ ~ 8812 • • ( 20 i~3175 ~ C5On CFM ~ 7 0 ~ ~10"D ~ n2~ - CRA Proj. No,: 07107.041 g"p 10"D 7 ~ S ~ V~ ~ Drawn by; JMH 1 ~ S 450/~ Checked By; WJD 8"D 5 7 n 2 CFM/ Date; 3/3/OS PLAN NOTES d 1'7000FM V 1.- EXISTING AIR DEVICE TO REMAIN. ADJUST LOCATION TO FIT FINAL NEW CEILING 3 175 8"D'' „DB 10'b\ Revisions CFM 2 GRID LOCATION SHOWN. REE3AIANCE TO VALUES SHOWN. 2.- REMOVE EXISTING AIR DEVICE AND ASSOCIATED BRANCH DUCTWORK SHOWN. 175 3 250 3 m 250 3 ~ 305 300 BR EA PREPARE FOR REINSTALLATION IN NEW LOCATION SHOWN. R1-10"X R1-1o"X22~EGEPTION cFM ~B9[~B 3.- EXTEND EXISTING BRANCH DUCT TO RELOCATED EXISTING AIR DEVICE AS SHOWN. REBALANCE TO VALUES SHOWN. J R1-10"X22"~ ~R1-10"X22" C~M 1 4.- EXISTING WATER SOURCE HEAT PUMP TO REMAIN. REBALANCE SYSTEM TO VALUES SHOWN. 5.- EXISTING AIR DEVICE TO BE REMOVED. ] 6,- EXISTING TEMPERATURE SENSOR FOR HEAT PUMP TO REMAIN, `~~r~en ~.E~ U~ 'i s ~ruct~res 7.- RELOCATE EXISTING HEAT PUMP TEMPERATURE SENSOR AS SHOWN. EXTEND ~ ~~ch~n~cal CONTROL WIRING AS REQUIRED. p~R CITY CaDE 8,- HC SHALL PROVIDE ACCESS PANEL TO HEAT PUMP UNIT. PROVIDE ACCESS PANEL CALL pLANNENG DIVISIDN IN DEMISING WALL ABOVE CEILING AS REQUIRED. RELOCATION OR REPLACEMENT OF UNIT WILL BE DONE AS PART OF FUTURE TENANT RENOVATION. ACCESS PANEL MUST PROVIDE FULL ACCESS. HVAC PLAN SCALE: 1/8~"=1'-0" NORTH H1 LEGEND AL ELECTRIC SPECIFICATIONS E EXISTING DEVICE 1.- A COMPLETE ELECTRICAL SYSTEM AS SHOWN ON THE DRAWINGS AND AS 13.- DEVICE AND JUNCTION BOXES GALVANIZED STEEL, C VANIZED STEEL, CODE GAUGE AND SIZE BY O N~3~N~ EC ELECTRICAL CONTRACTOR SPECIFIED HEREIN, WORK INCLUDES, BUT IS NOT NECESSARY LIMITED TO THE STEEL CITY, RACO, APPLETON OR R&S. BOXES CONNECTII BOXES CONNECTING MORE THAN ONE PAIR OF ~ r ~ ES EQUIPMENT SUPPLIER FOLLOWING PRINCIPAL CATEGORIES: CONDUCTORS TO BE MINIMUM 4" X 4", OR 4" OCTAGONP a.) WIRING DEVICES FOR DEVICES WHERE NUMBER OF CONNECTIONS OR OTHE OR 4" OCTAGONAL SIZE. USE ADAPTER PLATES ~ ~ ECTIONS OR OTHER CONDITIONS DICTATE. ~ GC GENERAL CONTRACTOR b.) POWER WIRING i w E OF STRUCTURE OR AGAINST TOP CHORD OF • O w Q • m ~ co o ~ ~ c. MISCELLANEOUS WIRING AND INTERLOCKS 14.- RUN CONDUITS AGAINST UNDERSIDE OF STRUCTURE HC HVAC CONTRACTOR ) JOISTS OR TRUSSES, WHETHER EXPOSED OR CONCEALED. d.) EQUIPMENT CONNECTIONS BE RUN IMMEDIATELY ABOVE ACCESSIBLE CEILINGS, USE I OR CONCEALED. IN NO CASE SHALL CONDUIT ~ ~ ~ 2 ~ o °o °0 0 MH MOUNTING HEIGHT TO CENTERLINE OF ITEM UNLESS INDICATED e.) PANELBOARDS CEILINGS, USE ONLY METALLIC CONNECTORS O ~ ~ ~ LIMIT CONDUIT SIZE TO 3/4", LARGER ~6' w ~ ~ o ~ 2 rn rn ~ OTHERWISE ON DRAWINGS, f.) LIGHTING FIXTURES AND FASTENERS. IN CONCRETE SLABS, LIMIT CONDUIT SIZ PC PLUMBING CONTRACTOR CONDUITS SHALL BE RUN UNDERSLAB. PLACE METALLIC PLACE METALLIC CONDUITS ABOVE VAPOR ~ 5~ ~ O ~ ~ ro 2,- OBTAIN AND PAY FOR ALL PERMITS. UPON COMPLETION, PROVIDE A CERTIFICATE BARRIER WHEN SLAB IS ON GRADE. WHERE FEEDERS ARE .RE FEEDERS ARE TO BE RUN BELOW FLOOR P R ~F ~ ~ ~ r ~ LLED IN CONDUIT ENCASED IN 3" CONCRETE, 0 9 `D `9 c R REMOVE EXISTING FOR RELOCATION OF INSPECTION FROM THE GOVERNING ELECTRICAL AUTHORITY, SLAB ON GRADE, THEY SHALL BE INSTALLED IN CONDUIT RE RELOCATED EXISTING 15.- ALL CONDUCTORS SHALL BE COPPER. MINIMUM SIZE ~ ~s'~ ro N o~~ ~ 3,- DURING THE BIDDING PERIOD, INSPECT THE SITE AND PREMISES OF PROPOSED ER. MINIMUM SIZE #12 AWG FOR BRANCH ~j UITS. BUILDING WIRING SHALL BE INSULATED ro lYP TYPICAL WORK. REPORT IMMEDIATELY ANY SIGNIFICANT OBSERVED DISCREPANCIES AS RELATED CIRCUITS; X14 AWG FOR CONTROL CIRCUITS. BUILDING WI TO THE PLANS OR REQUIRED WORK. ALL WORK SHALL COMPLY WITH NEC. FOR 600 VOLT, TYPE THW, THWN, XXHW, OR THHN, SUBJ OR THHN, SUBJECT TO MOISTURE AND HEAT ~ WP WEATHERPROOF LIMITATIONS STATED IN CODE. USE ONLY THW, THHN, OR 4.- WHERE TRADE NAMES, BRANDS OR MANUFACTURERS ARE LISTED, ANY ONE OF CONNECTIONS TO LIGHTING FIXTURES. ' THW, THHN, OR XHHW CONDUCTORS FOR PLAN NOTE SYMBOL -APPLIES ONLY TO SHEET ON WHICH NOTE IS SHOWN. THE SEVERAL NAMED ARE CONSIDERED EQUALLY ACCEPTABLE, NO UNNAMED PRODUCT r r. OR MATERIAL SHALL BE USED UNLESS IT IS LISTED AS A SUBSTITUTE DURING BIDDING, 16.- MISCELLANEOUS ITEMS OF EQUIPMENT REQUIRE WIRI EF- EQUIPMENT REFERENCE SYMBOL. WITH STATED CHANGE IN COST, AND APPROVED IN WRITING BY THE ARCHITECT OR FURNISH POWER AND CONTROL SOURCES FOR THESE AS ENT REQUIRE WIRING CONNECTIONS AS SHOWN, o -7--5 S FOR THESE AS SHOWN, OBTAIN ROUGH-IN d. \.J ENGINEER PRIOR TO PLACEMENT OF ORDERS, SUBMIT SHOP DRAWINGS ON MAJOR DRAWINGS AND INFORMATION ON FURNISHED CONTROLS F ~HED CONTROLS FROM THE EQUIPMENT ~ _~__J NNECTION BOXES IN AN INCONSPICUOUS BUT ~ w 123 ROOM NUMBER ITEMS OF EQUIPMENT AND MATERIALS. SUPPLIER. PLACE DISCONNECTS AND CONNECTION BOXES ACCESSIBLE LOCATION. COORDINATE LOCATIONS WITH E UI Q ATIONS WITH EQUIPMENT SUPPLIER AND THE ~ °a 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R 18" MH). HUBBELL 5352-W 5.- WORKMANSHIP SHALL BE FIRST CLASS. THE ARCHITECTS JUDGMENT SHALL ARCHITECT. ( PREVAIL IF THE QUALITY IS SUSPECT. ~ a SF DENOTES STORE FRONT RECEPTACLE MOUNT IN CEILING AT STORE FRONT, 17.- PROVIDE FUSES FOR EACH FUSE GAP IN FUSIBLE [ GAP IN FUSIBLE DISTRIBUTION EQUIPMENT AND 11 ~ 20A-125V DOUBLE DUPLEX RECEPTACLE. NEMA 5-20R (18" MH). TWO-GANG ASSEMBLY 6.- PROTECT MATERIALS AND EQUIPMENT AFTER DELIVERY TO THE JOB SITE. RESPECT DISCONNECT SWITCHES; BY BUSSMAN, GOULD-SHAWMUT OULD-SHAWMUT OR ECONOMY-RELIANCE, 1 11 SSMAN TYPE KRP-C. SMALLER FUSES UL 1111 U A ~ I-- OF TWO HUBBELL 5352-W. OTHER TRADES AS RELATED TO PROTECTING THEIR WORK AND TO AVOID FUSES OVER 600 AMP UL CLASS L; BUSSMAN TYPE KRP CONSTRUCTION INTERFERENCES. CALL ATTENTION TO PROBLEMS RELATING TO SPACE CLASS RK-i, BUSSMAN TYPE LPN-RK OR LPS-RK DUAL OR LPS-RK DUAL ELEMENT. FURNISH ONE TURN OVER TO THE OWNER AND RECORD IN 20A-125V RUPLEX RECEPTACLE, NEMA 5-20R (46" MH). HUBBELL 5352-W. REQUIREMENTS SO EARLY RESOLUTION MAY BE OBTAINED. RESPECT THE OWNERS SPARE FUSE FOR EACH FUSE REQUIRED; TURN OVER TO PROPERTY AT ALL TIMES, WRITING TO THE ARCHITECT. ' 111 1 ? ° ~ 11111 boo Y WITH LOCKING DEVICES, FUSED WHERE USED 11111 ~ ~ ~ ~ W 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R, WITH GROUND FAULT 7.- CUT AND PATCH TO INSTALL WORK WHERE FAILURE TO INSTALL SLEEVES OCCURS, 18.- DISCONNECT SWITCHES HEAVY DUTY WITH LOCKING I M SUCH WORK. IS ELECTRICAL ON SHALL BE TO PROTECT CIRCUIT WIRING. GF CIRCUIT INTERRUPTER (18" MH). HUBBELL GF-5362-W. OR PAY OTHERS TO PERFOR TH C TRACTOR PLAN NOTES O Z ~ ~ ~ E-- RESPONSIBLE TO PERFORM ALL OF HIS OWN CUTTING AND PATCHING OF FLOORS AND SINGLE POLE WALL SWITCH (46" MH). HUBBELL 1221-W. WALLS WHERE NECESSARY TO INSTALL ELECTRICAL EQUIPMENT. CONCRETE SHALL BE 19.- BRANCH CIRCUIT PANELBOARDS SHALL BE SQUARE JALL BE SQUARE "D" TYPE "NQOD" OR EQUAL ~ ~ ~ SAW CUT, NEATLY AND ACCURATELY, NECESSARY HOLES SHALL BE CORE DRILLED, BY ITE, G.E. OR PARK OHIO. BUSSING SHALL BE ALL COf SHALL BE ALL COPPER WITH SEPARATE 1. REMOVE AND REINSTALL LIGHT FIXTURES. REFER TO NEW WORK LIGHTING P(AN ~ ~p FOR ADDITIONAL INFORMATION. ~ THREE-WAY WALL SWITCH (46" MH). HUBBELL 1223-W. PATCHING SHALL BE DONE TO MATCH BOTH THICKNESS AND FINISH OF ADJACENT GROUND BAR, CIRCUIT BREAKERS SHALL BE BOLTED TYPE MATERIAL. GENERAL CONTRACTOR SHALL DO ALL PATCHING WORK PAID FOR BY THE BRANCHES AND 42,000 A.I.C. FOR MAIN BREAKERS. CABIP BE BOLTED TYPE WITH 10,000 A.I.C. FOR • P. BREAKERS. CABINETS SHALL BE 20" WIDE W ~ ~ 1000W DIMMER LUTRON NOVA T DIMMER WHITE COLOR ELECTRICAL CONTRACTOR. MINIMUM WITH HINGED AND LOCKED DOOR, ALL PANELBOE )R, ALL PANELBOARDS KEYED THE SAME. ~ ~ ° OCCUPANCY CONTROL SENSOR - WATTSTOPPER OR EQUAL. WHITE COLOR. 8.- THE ELECTRICAL CONTRACTOR SHALL REMOVE ALL EXISTING WORK WHICH IS 20.- REFER TO THE DRAWINGS FOR INFORMATION ON FIX c+i n/ FORMATION ON FIXTURES, LAMPS AND ~ ~ ~ LJ_ KINDRED TO HIS TRADE AND SUPERFLUOUS WHEN THE NEW SYSTEM IS INSTALLED. MANUFACTURERS. ALL FIXTURES SHALL BE NEW AND U.L. 3E NEW AND U.L. LABELED. LAMPS SHALL BE rI~ o fINGHOUSE OR VENTURE. ? t j ~ ~ ~ ELECTRICAL CONNECTION REQUIRED COOPERATE WITH THE GENERAL CONTRACTOR AND REMOVE EXISTING UNUSED CONDUIT MANUFACTURED BY G.E., SYLVANIA, WESTINGHOUSE OR VE TO BEHIND WALLS OR BELOW FLOORS AS NECESSARY OR AS DIRECTED. UPON I EXIT LIGHTING FIXTURE. ARROWS AS INDICATED. CEILING MOUNTED. COMPLETION, NO UNUSED CONDUIT OR STUB, OR JUNCTION BOX SHALL EXTEND THRU 21.- BRANCH CIRGUITS FOR LIGHTING AND RECEPTACLE I ,ND RECEPTACLE CIRCUITS MAY BE TYPE "MC" G ~ ~ 3Y NEC. "MC" SHALL BE USED ONLY WHERE W ~ • CONNECT AHEAD OF LOCAL SWITCHING. FLOORS, WALLS OR CEILINGS. ABANDONED CONDUIT WHERE REMAINING IN PLACE CABLE ASSEMBLIES, WHERE PERMITTED BY NEC. "MC" SHi SHALL HAVE ALL UNUSED WIRING REMOVED. MATERIAL AND EQUIPMENT WHICH IS CONCEALED IN WALLS OR ABOVE CEILINGS AND SHALL BE GS AND SHALL BE PROPERLY SUPPORTED. I EXIT LIGHTING FIXTURE. ARROWS AS INDICATED. WALL MOUNTED AT 3" REMOVED SHALL NOT BE REUSED IN THIS PROJECT, ABOVE DOOR TRIM OR BELOW CEILING AS REQUIRED. CONNECT AHEAD g,_ THE BUILDING NEUTRAL SHALL BE IDENTIFIED THROUGHOUT BY A WHITE 22.- MOT USED OF LOCAL SWITCHING. CONDUCTOR. WORK INCLUDES GROUNDING OF SYSTEM NEUTRAL, EQUIPMENT AND 23,- AS EACH ELECTRICAL SYSTEM IS COMPLETED, IT SH q~,p EXIT LIGHTING FIXTURE, WITH INTEGRAL EMERGENCY EGRESS LIGHTING. CONDUIT SYSTEMS TO CONFORM TO N.E.C. GROUND RODS SHALL BE COPPER CLAD, FREEDOM FROM GROUND AND THAT REQUIRED FUNCTIONS :OMPLETED, IT SHALL BE TESTED TO ASSURE ~ • • !UIRED FUNCTIONS ARE PERFORMED, WORK MOLTEN WELDED COPPER TO STEEL, 5 8 DIAMETER X 10 LONG. RUN GREEN CEILING OR WALL MOUNTED, CONNECT AHEAD OF LOCAL SWIITCHING. / SHALL BE INSPECTED AND APPROVED BY THE LOCAL INS( GROUND CONDUCTOR IN ALL CONDUITS. PROVIDE BONDING JUMPER. JURISDICTION. PERFORM SPECIAL RESISTANCE TESTS WHEP t' THE LOCAL INSPECTION AGENCY HAVING H1 RE LIGHTING FIXTURE; CAPITAL LETTER DENOTES FIXTURE TYPE. LOWER CASE 10.- WIRING DEUICES AND GROUND FAULT INTERRUPTERS BY P&S, A.H. BRYANT OR INSPECTION AGENCY TO PROVE THE SYSTEM'S INTEGRITY. ANCE TESTS WHEN REQUESTED BY THE TEM'S INTEGRITY. FURNISH TO THE OWNER, Q LETTER DENOTES SWITCHING ARRANGEMENT. G.E. EQUAL TO CATALOG NUMBERS SHOWN ON THE DRAWINGS, WALL PLATES PLASTIC THROUGH THE ARCHITECT, A FINAL INSPECTION CERTIFICA. b ECTION CERTIFICATE, NON-COMBUSTIBLE 0.100" THICK, COLOR TO MATCH DEVICE. 24,- IDENTIFY THE FOLLOWING: PANELBOARD SWITCHES A )ARD SWITCHES AND BREAKERS, INDICATING H1 RE LIGHTING FIXTURE ON NIGHT LIGHT CIRCUIT. CONNECT AHEAD OF LOCAL SWITCHING, SERVICE; DISCONNECT SWITCHES AND MOTOR STARTERS; l ® 11.- CONDUIT SHALL BE USED FOR ALL WIRING, EXCEPT AS NOTED FOR "MC" CABLE PANELS; SAME DESIGNATION SHOWN ON THE DRAWINGS AI )TOR STARTERS; LABEL BRANCH CIRCUIT THE DRAWINGS AND TYPE IN THE PANELBOARD ASSEMBLIES. CONDUIT SYSTEMS MAY BE ANY ONE OR COMBINATION OF THE CIRCUIT DIRECTIONS INDICATING THE TYPE LOAD AND GEN 'E LOAD AND GENERAL LOCATION. USE ~ A-1&2 FOLLOWING, WITHIN RESTRICTING LIMITS INDICATED. CONDUIT TYPES NOT LISTED SHALL ENGRAVED, LAMINATED PLASTIC PLATES FOR LABELING SWI EACH ARROWHEAD REPRESENTS ONE COMPLETE CIRCUIT; CAIPTAL LETTER NOT BE USED. =0R LABELING SWITCHES AND PANELBOARDS. .Q DENOTES PANEL; NUMBER DENOTES CIRCUIT, a.) RIGID GALVANIZED CONDUIT - NO RESTRICTIONS. 25,- DEMONSTRATE FUNCTIONS PERFORMED BY DEVICES MED BY DEVICES AND SYSTEMS TO THE ~ WIRE & CONDUIT IN WALL OR ABOVE CEILING b.) INTERMEDIATE GRADE GALVANIZED THREADED CONDUIT - NO RESTRICTIONS. OWNER'S REPRESENTATIVE. FURNISH TO THE OWNER DATA c.) THINWALL CONDUIT WITH APPROVED CONNECTOR FITTINGS TO ASSURE GROUNDING AND FREQUENCY OF MAINTENANCE REQUIRED FOR SWITCH THE OWNER DATA SHEETS INDICATING NATURE Q 11RED FOR SWITCHES, DEVICES AND EQUIPMENT. WIRE & CONDUIT IN OR BELOW FLOOR SLAB OR BELOW GRIADE CONTINUITY, SUBJECT TO THE FOLLOWING RESTRICTIONS: ASSEMBLE AND DELIVER TWO (2 BOUND COPIES OF THIS COPIES OF THIS DATA. 1. HAZARDOUS OR CORROSIVE ATMOSPHERES. ~EE ALL WORKMANSHIP, EQUIPMENT AND J JUNCTION BOX 2. NOT IN POURED CONCRETE, OUTDOOR OR UNDERGROUND. 26,- THIS CONTRACTOR SHALL GUARANTEE ALL WORKMAN 3. EXPOSED BELOW 96" MATERIAL ENTERING INTO THIS CONTRACT FOR A PERIOD f FOR A PERIOD OF ONE (1) YEAR FROM THE d.) FLEXIBLE METAL CONDUIT (GREENFIELD TYPE) GALVANIZED. USE RESTRICTED TO DATE OF ACCEPTANCE, INCLUDING LAMPS AND BALLASTS. HEAVY DUTY DISCONNECT SWITCH THE FOLLOWING APPLICATIONS: DEFECTNE DURING THIS PERIOD SHALL BE MADE GOOD B S AND BALL4STS. ANY WORK PROVEN TO BE BE MADE GOOD BY THIS CONTRACTOR WITHOUT 1. CONNECTIONS TO LIGHTING FIXTURES, MAXIMUM LENGTH 6 FT. EXPENSE TO THE OWNER. ~ CIRCUIT BREAKER PANEL (SURFACE MOUNTED) e.) LIQUID TIGHT FLEXIBLE METAL CONDUIT WITH WATERTIGHT OIL RESISTANT OUTER PVC COVERING. USE REQUIRED: 27.- THE CONTRACTOR SHALL SUBMIT A COMPLETE SET ~ 1 COMPLETE SET OF "AS BUILT" DRAWINGS TO PHONE/DATA OUTLET (18"M.H, EXCEPT WHEN SUBSCRIPT "WY" IS USED, 1. CONNECTIONS TO MOTORS OR CONTROL ON DYNAMIC EQUIPMENT. THE OWNER AT THE COMPLETION OF THE PROJECT. THE E PROJECT. THE DRAWINGS ARE TO SHOW ALL SIZES. MOUNT AT 46" M.H), DOUBLE GANG BOX WITH SINGLE GANGS REDUCER 2. CONNECTIONS TO FURNITURE ELECTRICAL OUTLETS. CONDUIT, DEVICES, WIRE QUANTITY AND SIZES. AND BLANK COVER PLATE. EXTEND A 1" BUSHED CONDUIT WITH PULL f.) RIGID NON-METALLIC (SCHEDULE 40 PVC) CORD OUT ABOVE NEAREST ACCESSIBLE CEILING. 1, THIS CONDUIT MAY BE USED IN OR UNDER CONCRETE SLABS ON GRADE, IN 28,- PROVIDE NEW FIRE ALARM DEVICES AS REQUIRED. „ CONCRETE DUCT E3ANKS, AND DIRECT BURIED. ALARM SYSTEM. MODIFY SYSTEM AS REQUIRED TO HANDLE i AS REQUIRED. CONNECT TO EXISTING FIRE IUIRED TO HANDLE ADDITIONAL AV LOAD. ALL © FIRE ALARM ADA SIGNALING LIGHT. (BD MH) 2. THIS CONDUIT MAY NOT BE RUN EXPOSED WHERE SUBJECT TO PHYSICAL S'E~OBES IN COMMON AREAS MUST BE SYNCHRONIZED, E. SYNCHRONIZED, E.C. SHALL PROVIDE SHOP )VIDE 4 COPIES TO THE ENGINEER FOR DAMAGE. DRAWING FOR REVIEW & APPROVAL. PROVIDE 4 COPIES T ~F FIRE ALARM SIGNAL PULL-STATION STATION (46" MH) 3. TYPE EB MAY BE USED WERE UL LISTED FOR SPECIFIC USE INTENDED. APPROVAL & FORWARD TO THE CITY FOR PERMIT. THIS I; R PERMIT. THIS IS TYPICAL FOR ALL FLOORS WHERE NEW WORK IS BEING PERFORMED. DEVICES SHALL F~ FIRE ALARM HORN STROBE (80" MH) 12,- CONDUIT FITTINGS SHALL BE MANUFACTURED BY EFCOR, STEEL CITY, RACO, CONTROL PANEL. E.C. SHALL MODIFY THE SYSTEM AS NEI DEVICES SHALL MATCH EXISTING FIRE ALARM E SYSTEM AS NECESSARY TO PROVIDE THE MIDWEST, ETP OR T&B. REQUIRED OPERATION. MOTORIZED EQUIPMENT CONNECTION. a.) WHERE THE METALLIC CONDUIT SYSTEM IS USED AS THE EQUIPMENT GROUNDING SYSTEM: ~ ~ EXISTING LIGHT FIXTURE TO BE REMOVED AND/OR RELOCATED. LINE 1. RIGID CONDUIT -COUPLINGS SHALL BE THREADED STEEL_ CONNECTIONS - I ~ I TYPE TYPICAL FOR ALL DEVICES TO BE REMOVED AND OR (RELOCATED. SHALL BE SET SCREW, ALL STEEL, CONCRETE TIGHT WITH NON INSULATED THROAT, L_J / GROUND BUSHINGS, MALLEABLE IRON, INSULATED. 2. EMT -FITTINGS SHALL BE ALL STEEL COMPRESSION TYPE, CONCRETE TIGHT. DASHED SYMBOL INDICATES THAT PARTICULAR OUTLET OR DEEVICE TO BE 3. FLEXIBLE CONDUIT -MALLEABLE IRON, "SQUEEZE" TYPE. REMOVED AND CIRCUITRY MADE CONTINUOUS WHERE REQUIRED, 4. LIQUID-TIGHT CONDUIT -STEEL OR MALLEABLE IRON. © SECURITY SYSTEM CARD READER. (46" MH), PROVIDE WALL EBOX PER ~ 4- ~ ~ MANUFACTURER'S INSTRUCTION AND 3/4" CONDUIT STUBBED> TO ABOVE ACCESSIBLE CEILING. IS ~ ~ ~ °P3 EXIST J ~ DUAL SERVICE POWER POLE FOR POWER AND DATA TO SYSITEMS EXIS PP FURNITURE. LENGTH AS REQUIRED COORDINATE COLOR WITH TENANT. H3 "P3AA" EXIS EXIST f~! E E E E E ~ ~ U "L4' ON 4 ..P3„ ? E O L PE DOEI----i i----i i----i Q. ¦ - LOL ----J L----J ~ r~ ~----~-r---- ~ N E i I I I I E ~ ~l ~E E E FLOOR BOX, O EE E E J TERMINATE `u O 0 E BELOW FLOOR E F J E E O E E F E JE J E RD RD I" ~ R E O a E E ~M~ 0 RD • • 0 1 ° 0 E ® J E ~ ~ R~ CRA Proj. No.: 07107.041 E E E jk7 R~ R~ R~ R~ E J Drawn by: E ~R E 7I1~- E Checked By: ° ~ E R~ Date; 313108 ° Ra R ° E ~ R~ R~ R~ Revisions 3 O L_J ° ' ' R~ R~ ~ 3 ~ ~ LuVk c~ ~~~,~j~/jj~ y c 0 y 1Tan~ ~ / c~ u ~ R ~ II 1- ~1 J o ?lV= ~ 7 R ~ ° R R ° r GF E I ~~4- ~ ~ ~ ~ R 4 ICS ~.~i R ° `4~" R ° ~ ~ ~ ~ `~J ~ I u ~ ~ I R 3 ~ R 3 E ° ° 1S ~(1S ~ ~ ~ 0 ° ~ ~ ~ ° ELECTRICAL R ~ ~ R R ° R ° ~ R R ~r•~ F ~ 0 0 ~ 0 ~r ~ DEMOLITION r + ~r ~ 0 E J J E • • 0 ~ ~ ~ E R E E E t J V y 4~ 7A_~7 ELECTRICAL DEMO SCALE: 1/8"=1I-0't NORTH \o N~~~Ni ~ ~ ~ a~~ ~ ~ W • ~ W r- J y • us ~ ~ ~ ro~'o°o°oo - - EM Yd ~ ~ O acn~rcv j ~ o =m~Y ~0 RE RE RE RE E~ ° ~ ~ ~ ro I O S RU ROM pRpF ~ ~ ~ ~ 0 OC a a a 311 ~ Oa ~ `m a t ~~U11 V 0 A ~ E RE RE RE RE RE ~ 0 © r. o a a d' a a a ~ ~ u _ 0 01 RE ~ a 304 ~ OOM RE RE OPEN WORK RE RE 11 1 I ~ RE X~ ~ ~ IV l RE RE CC ~ 11111 V Q ~ f RE b b RE NL b b 111 1 U ~ U X1~ 1 1 Z o ~ a b `X1 11111 - b o`O0 RE RE RE RE RE 11111 ? z ro ~ ~ ~ NL OC RE IRE b b ca RE Q 'E b ~ ~ ~ W a• U f W UU RE 302 Z ~ X1 ONFER RE RE RE 305 ~ ~ TIOP TION K AREA o © RE U RE RE FRE b b b ~ ~ W ° b RE • • • i 200A 200A ~ . O ELECTRICAL LIGHTING PLAN SCALE; 1/8"=1'-0" NORTH EXIST "P3" IS Is EXIS "P3A" "H3" EXIST "P3A" EXIST "P3AA" "P3AA" . E~X?IS EXIST EXIST ..P3.. ? ON 4 "P3.. TO SPD-1 EXIST EXIST EXIST 800A "P3A" "P3AA" "P4,. C ~ 4 - - - O 04 ~ I ~ O 00 S RVER R M MGR CUBE E L~ 1 0 00 d ~ 8x12 ~ E~ O O ~ ~ o a ~ ~ E ~ O ~ ~ O 0 SCALE: NONE O © O MGR CUBE E Bx12PCWEIR ~ ~ ~ U J 301 ~ ~ 304 EXISTING • n~ ~ WORK ROOM DATA ~ ' ~ PEN W RK ~ 0 E MGR CUBE ~ 8212 ~ ~ ~ - c~ r~~ ~ Q2 CR ~ GENERAL NOTES I ~ ~ ~ EXISTING PANEL: P3AA O3 ~ G E # A. REFER TO FIRE ALARM DRAWING FOR ALL FIRE ALARM MODIFICATIONS. Q2 ~ • CONN. LOAD: EXIST - 3.6 KVA DEMAND LOADEXIST - 1.8 KVA (EXIST - 1 A) B, EACH HEAT PUMP HAS A SMOKE DETECTOR IN FRONT OF THE RETURN RETURN ~~jj • U~~~ ~ MAINS: 100A MLO VOLTAGE: 208/120V.,3PH.,4W. AIR OPENING. MAINTAIN EXISTING SHUT DOWN OF HEAT PUMP UNITS. m 6 BB 6 BB B m 5 CRA P~oj: No+ 07107,041 LOCATION; MOUNTING: SURFACE C. ALL 2x4 LIGHT FIXTURES ARE EXISTING TO BE REUSED. RELAMP ANY UNMACTHED 300 ~ 302 ~ ~ ~Q2 E ~ 305 Drawn~by: OR NON-OPERATIONAL LAMPS. REMARKS KVA BKR. CKT. N0. BKR, KVA REMARKS AND PH. C O 9~]99[~96~99[~9 BR EA Checked BY4 Date:,, 3/~/~~ C E EXISTING 20/1 1 A 2 20/1 EXISTING PLAN NOTES EXISTING 20/1 3 B 4 20/1 EXISTING Revisi~pns'~ E EXISTING 20/1 5 C 6 20/1 EXISTING 1. CHANGE EXISTING DUPLEX OUTLET TO A DOUBLE DUPLEX OUTLET. ~ ~ ~,~sF:,. EXISTING 20/1 7 A 8 20/1 EXISTING E EXISTING 2. CIRCUIT TO SPARE SINGLE POLE 20A, 120V CIRCUIT BREAKER IN EXISTING "P3AA" 20/1 9 B 10 20/1 EXISTING OR "P3A" AS REQUIRED. E EXISTING 20/1 11 C 12 20/1 EXISTING E EXISTING 20/1 13 A 14 20/1 EXISTING 3. PATH FOR DATA TO SYSTEM FURNITURE. PROVIDE CADY RINGS AND GROMMETS AS EXISTING 20/1 15 B 16 20/1 EXISTING REQUIRED. E EXISTING 20/1 17 C 18 20/1 EXISTING 4. VERIFY MOUNTING HEIGHT WiT EXISTING H ARCHITECTURAL ELEVATIONS PRIOR TO ROUGH IN. 20/1 19 A 20 20/1 EXISTING EXISTING 20/1 21 B 22 20/1 EXISTING 5. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH CASEWORK SPARE 20/1 23 C 24 20/1 EXISTING CONTRACTOR PRIOR TO ROUGH IN. SPARE 20/1 25 A 26 20/1 EXISTING 6. CONNECT TO EXISTING CIRCUIT IN AR SPARE 20/1 27 B 28 20/1 EXISTING EA FROM EXISTING 277V PANEL "L2" ON 4TH FLOOR. ELECTRICAL SPARE 20/1 29 C 30 20/1 SPARE PLAN SPARE 20/1 31 A 32 20/1 SPARE SPARE 20/1 33 B 34 20/1 SPARE SPARE 20/1 35 C 36 20 1 LIGHT FIXTURES / SPARE SPARE 20/1 37 A 38 20/1 SPARE SPARE 20/1 39 B 40 20/1 SPARE RE.- LITHONIA ~2SP8-332-A12125-277-GEB WLP 735 OR EQUAL BY DAYBRITE OR SPARE 20/1 41 C 42 20/1 SPARE LSI. PROVIDE 2 BALLASTS FOR DUAL LEVEL LIGHTING TO MEET CODE. I NOTE: LEM.- u A #LNUM-SW-3-R-120/277-N OR EQUAL BY MCPHILBEN OR DUAL LITE. NEW DEMAND. THIS PROJECT REMOVED 33 DUPLEX RECEPTACLES AND ADDED 24 NEW - LITHONIAELM2-120/277 OR EQUAL BY MCPHILBEN OR DUAL LITE. RECEPTACLES. FOR AN OVER ALL REDUCTION OF 9 DUPLEX RECEPTACLES. THE QUAINTLY OF LIGHT FIXTURES WERE REDUCED FROM 40 TO 34, FOR A TOTAL DEMAND LOAD REDUCTION OF 2340 WATTS. ELECTRICAL POWER PLAN E2 SCALE: 1 /8"=1'-0" NORTH