Loading...
03200950 Permit File CITY OF DUBLIN 5800 Shier Rings Road Division of Building Standards Dublin, Ohio 43016 COMMERCIAL BUILDING Telephone: 614-410-4670 PERMIT APPLICATION Inspection Line: 614-4104680 Facsimile: 614-761-6566 PROJECT INFORMATION Address 6419 Old Aver Road Projectgq Ftg 5400 rojectName Hilliards Furniture Retail Addition _ Estimated Cost of Construction $394, 000. Parcel Number 273-000303 PROPERTY OWNER INFORMATION Property Owner Name (Contact Person if owned by a Corporation) James R. McKitrick ompanyName Hilliards Furniture,Inc. Address 6419 Oid very oa 'ty Dublin State OH zip T one 14 9-805 Fax E-MailTENANT INFORMATION (If Applicable) (NA) Contact Name Company Name Address dy State Zip Telephone Fax E4M ARCHITECT, ENGINEER, OR OTHER DESIGN PROFESSIONAL INFORMATION Design Professional Name_ Joseph P. Borghese Ohio Reg/Cert Number Ohio 10741 ompanyNameJa_ck D. Walters &Assoc. a Inc. Address 5166 Blazer Memorial Pir-Z a City Dublin State QH Zip 43017 Telephone_614/889-2516 Fax 614 889-5596 E-Mail GENERAL CONTRACTOR INFORMATION (Must be a City of Dublin Registered Contractor) Contact Name Phillip Hochstetler Dublin Registration4 03-2232 mpanyName Hockstetler Buildings, Inc. Address 7927 Memorial Drive City Plain City state OH zip. el one 614/873-3439 Fax 614/873-3722-- E-Wp i oc stet er.net AFFIDAVIT OF OWNER AUTHORIZATION FOR REPRESENTATION Note: This person will be contacted with all official correspondence. All signatures must be ORIGINAL Owner's Representative Joseph P. Borghese Relationshi to Project Project Architect Company Name Jack D.Walters ssoc. nc . Position l~ro j ect rc Telephone 614/889-2516 I, James R. McKitrick (please print), the owner and applicant, hereby authorize Joseph P. Borghese to act as my representative and agent in all matters pertaining to the processing and approval of this application including modifying the project, and I agree to a bound by all repr entations d agreements made by the designated agent Signature of Property Owner: l Date: I, Joseph P. Bor ese the Owner or the Owner's Representative, have read and understand the contents of all 3 pages of this application. The information contained in this Application, attached exhibits and other information submitted is complete and in all respects true and correct, to the best of my knowledge and belief. ignature of Owners Re resentative: Date: July 08, 2003 mamn [Building Standards ivision Use Only Date Received Bul i cation Number JUL 0 8 ,2003 -03 BUCOMMERCIAL BDIIDING PERMIT APPLICATION Page I W I PiPASS%8tDG\FORMS%COMMAPP.VM I I N G `rI°tTOF MB'k'M CITY OF DUBLIN Division of Building Standards COMMERCIAL BUILDING PERMIT APPLICATION Project Name Hilliards Furniture, Retail Addition Permit Number PROJECT INFORMATION NOTE: The following information is to be completed by the Design Professional, registered in the State of Ohio, who was primarily responsible for the preparation of the construction documents. Scope of Project Building addition, with associated alterations to existing building and site. TYPE OF WORK (Check all that apply) 5400 sf Addition (includes covered entry) A. New Stricture B. Addition Tx- Fire Wall Yes x No C. Alteration x Article 34 Yes x No D. Change of Use Entire Structure Partial E. Change of Occupan Entire Structure Partial Previous Use(s) Retail, with Stockrooms Use Group(s) M ANALYSIS OF NEW STRUCTURE, ADDITION, AND/OR AREA TO BE ALTERED A. Occupancy Description Retail Use Group(s) M B. Mixed Use: Yes Non-separated =Separated F1 No x C. Type of construction_ V-B, combustible, unprotected D. Fire resistive construction Fire Test Design Numbers Exterior Walls hr. Fire Walls 3 hr. U9049 U905 Floor/Ceiling hr. Columns/Bearing Wall hr. Exit Enclosures hr. Shafts hr. Corridors hr. Tenant Separation hr. E. Floor Area/Floor Occupant Load/Floor Egress Capacity/Floor Number of Exits Basement 9st 17.379 448 144U- (6) 2nd 3rd 4th & above 6155 sf and. 11224 sf fire areas, existing building, + 5400 sf ot addition F. Allowable maximum floor area (first floor footprint) 13,869 sf Does the above include street frontage increase? Yes No~ Does the above include increase for sprinklers? Yesxx No G. Number of stories above grade 1 Height 25 ft. BasementYes[-1 WE] -CO,MIM MAL WuxNG PFRMf7APPucmm Page 2 of 3 P-1PASSOLDGWCIRMS COMMAPpM2 Fom* OLD-201 Date: 10111M CITY OF DUBLIN j Division of Building Standards COMMERCIAL BUILDING PERMIT APPLICATION H. Horizontal exits Yes x No 1. Limited sprinkler system Yes No xx J. Full automatic sprinkler system Yes No xx K. Standpipe system Yes No xx L. Smoke control/Removal system Yes No xx M. Unlimited area building Yes No xx N. Manual fire alarm Yes No xx 0. Auto fire alarm Yes No xx P. Handicap accessible route (exterior & interior) Yes xx No Q. Structural Loads: provide table of design loads with construction documents EXISTING STRUCTURE ANALYSIS (Complete for all alteration or addition projects) A. Occupancy Description Retail/Stockrooms Use Group(s) ~M) B. Mixed Use: Yes ® Non-separated =Separated 0 No C. Type of construction VB, combustible/unprotected D. Floor Area/Floor Occupant Load/Floor Egress Capacity/Floor Numbevof Exits Basement 1 11, 1st 11,979 273 900 (4) 2nd 3rd 4th & above E. Allowable maximum floor area (first floor footprint) 13, 869 Does the above include street frontage increase? Yes xx NoRxx Does the above include increase for sprinklers? Yes No F. Number of stories above grade 1 Building Height 25 ft Basement Yes= No M G. Horizontal exits Yes No H. Limited sprinkler system Yes No 1. Full automatic sprinkler system Yes No xx J. Standpipe system Yes No xx K. Smoke control/Removal system Yes No xx L. Unlimited area building Yes No xx M. Manual fire alarm Yes No xx N. Auto fire alarm Yes No xx 0. Handicap accessible route (exterior & interior) Yes xx No P. Structural Loads: provide table of design loads with construction documents I, Joseph P. Borghese , the Design Professional, have read and understand the contents of this application. The information contained in this application, attached exhibits and other information submitted, is complete and in all respects true and correct, to the best of my knowledge and belief. y~ Signature of Design Professional: Date: July 08, 2003 COMMERCIAL BUILDING PERMIT APPLICATION Pape 3 of 3 P:IPASS8LDGIFORM=OMMAPP.WB2 FormtM BLD-201 Date:10/11199 CITY OF DUBLIN Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Application Number . . . . . 03-00200950 Date 10/31/03 Revision number . . . . . . . 5 Pin number . . . . . . .580650 Property Address . . . . . . 6419 OLD AVERY RD Parcel Number . . . . . . . . 273-000303 Alternate Address . . . . . . BILLIARDS FURNITURE Tenant nbr, name . . . . . . HILLIARD FURNITURE Application description . . . COM BUILDING ADDITION Property owner . . . . . . . MCKITRICK JAMES R Contractor . . . . . . . . . HOCHSTETLER BUILDINGS, INC. Structure Information Construction Type . . . . 5B - UNPROTECTED COMB Occupancy Type . . . . . . MERCANTILE Permit . . . . . COMMERCIAL BUILDING PERMIT Additional desc . . Permit Fee . . . . 650.00 Plan Check Fee .00 Issue Date . . . . -0--ZD Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 150.00 10.00 50.0000 THOU COM BLDG PLAN REVIEW 500.00 Permit . . . . . . LOW VOLTAGE ELECTRIC PERMIT Additional desc . . Permit Fee. . . . . 230.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 30.00 10.00 20.0000 THOU COM ELECTRIC LOW VOLTAGE 200.00 Special Notes and Comments SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 MAINTAIN/INSTALL PROTECTIVE TREE FENCING DURING ALL PHASES OF CONSTRUCTION SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 MAINTAIN/INSTALL PROTECTIVE TREE FENCING DURING ALL PHASES OF CONSTRUCTION APPROVAL FOR CONSTRUCTION OF MAJOR BUILDING AND SITE EXPANSION OF EXISTING FURNITURE STORE. SEE RECORDS OF ACTION #03-023DP (DATED 4/17/03) AND #02-007Z This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. -fig. ~ o~ a .,CITY OF DUBLIN 5800 Building 5800 Shier-Rings Rood Dublin, Ohio 43016-1236 I I Ni 1G~(' s Furr~1 ur¢, 6419 014 Aver Rog4 y DvLh~ oN 43016 PREPARED 2/22/08, 12:34:48 INSPECTION HISTORY REPORT PAGE 4 PROGRAM BP521L 1/01/03 THRU 0/00/00 CITY OF DUBLIN APPLICATION PROPERTY ADDRESS Parcel Number Alternate Address STRUCTR PERMIT INSPECTION RESULT DATE/STATUS INSPECTOR 03 00200950 CONTINUED 000 000 CELE 00 COM ELECTRIC SERVICE P19 0003 ELECTRIC FINAL 8/24/04 APPROVED TZ 000 000 CHVA 00 COM HEATING, VENTILATING, A.C. P11 0001 HVAC ROUGH 4/02/04 APPROVED KM REQ COMM: 873-3439 phil REQ COMM: no hvac permit issued not sure if one is needed. RES COMM: furnaces not set 000 000 CHVA 00 COM HEATING, VENTILATING, A.C. P28 0001 HVAC FINAL 7/29/04 DISAPPROVED TJ REQ COMM: Wayne 570-6857 RES COMM: space has been occupied without ok no further inspections 000 000 CHVA 00 COM HEATING, VENTILATING, A.C. P28 0002 HVAC FINAL 8/03/04 DISAPPROVED TJ REQ.COMM: 879-9091 RES COMM: need to test fire dampers PREPARED 2/22/08, 12:34:48 INSPECTION HISTORY REPORT PAGE 3 PROGRAM BP521L 1/01/03 THRU 0/00/00 CITY OF DUBLIN APPLICATION PROPERTY ADDRESS Parcel Number Alternate Address STRUCTR PERMIT INSPECTION RESULT DATE/STATUS INSPECTOR 03 00200950 CONTINUED REQ COMM: 314-2156 RES COMM: wiring not complete RES COMM: no trench warning tape RES COMM: service lateral covered befor inspection RES COMM: water in trench RES COMM: pole riser not complete RES COMM: could not locate electric drawings RES COMM: no one on site 000 000 CELE 00 COM ELECTRIC SERVICE ELSE 0002 ELECTRIC SERVICE 4/22/04 DISAPPROVED BR REQ COMM: 314-2156 RES COMM: service not built as per drawings 000 000 CELE 00 COM ELECTRIC SERVICE ELSE 0003 ELECTRIC SERVICE 5/05/04 DISAPPROVED BR REQ COMM: 314-2156 RES COMM: contractor to submit new service drawings 000 000 CELE 00 COM ELECTRIC SERVICE ELSE 0004 ELECTRIC SERVICE 5/13/04 DISAPPROVED WITH PEN TZ REQ COMM: 314-2156 RES COMM: 1. Service lateral and feeder conduits buried before RES COMM: inspection. RES COMM: 2. Service disconnects not bonder to the wireway. RES COMM: 3. Neutrals improperly derated from 3/0 to2/0. RES COMM: 4. Service not installed per drawings (concrete encasement, RES COMM: sch.80). 000 000 CELE 00 COM ELECTRIC SERVICE ELSE 0005 ELECTRIC SERVICE 5/24/04 CANCELLED TZ REQ COMM: 314-2157 000 000 CELE 00 COM ELECTRIC SERVICE ELSE 0006 ELECTRIC SERVICE 5/26/04 APPROVED TZ REQ COMM: 873-3439 000 000 CELE 00 COM ELECTRIC SERVICE P4 0002 ELECTRIC UNDERGROUND 6/09/04 APPROVED BR REQ COMM: 314-2156 000 000 CELE 00 COM ELECTRIC SERVICE P19 0001 ELECTRIC FINAL 8/02/04 DISAPPROVED TZ RES COMM: 1. Pole lights not installed. RES COMM: 2. MC cables in the office ceiling not properly strapped to RES COMM: the tie wires. RES COMM: 3. Improper working clearance in front of the old panel. RES COMM: 4. Waterpipe bonding jumper required between hot and cold RES COMM: lines. RES COMM: 5. Improper working clearance in front of the lift station RES COMM: panel and controls. RES COMM: 6. Conduit at service requires a strap. RES COMM: 7. Site lighting at the entry is not complete. RES COMM: 8. Approved electrical plans are not available. 000 000 CELE 00 COM ELECTRIC SERVICE P19 0002 ELECTRIC FINAL 8/04/04 DISAPPROVED WITH PEN TZ REQ COMM: 314-2156 RES COMM: Items #1,3,& 7 not completed. PREPARED 2/22/08, 12:34:48 INSPECTION HISTORY REPORT PAGE 1 PROGRAM BP521L 1/01/03 THRU 0/00/00 CITY OF DUBLIN APPLICATION PROPERTY ADDRESS Parcel Number Alternate Address STRUCTR PERMIT INSPECTION RESULT DATE/STATUS INSPECTOR 03 00200950 6419 OLD AVERY RD 273-000303 HILLIARDS FURNITURE 000 000 BCOM 00 COM BLDG PERMIT P2 0001 BLDG FOOTING 1/09/04 APPROVED JR REQ COMM: 3:30 insp REQ COMM: 873-3439 000 000 BCOM 00 COM BLDG PERMIT P2 0002 BLDG FOOTING 1/30/04 APPROVED JR REQ COMM: 873-3439 phil RES COMM: post holes heated 000 000 BCOM 00 COM BLDG PERMIT P3 0001 BLDG PRE SLAB 3/09/04 DISAPPROVED EL REQ COMM: phil 873-3439 REQ COMM: hilliard furniture RES COMM: no 6X6 WWF on site. 000 000 BCOM 00 COM BLDG PERMIT P3 0002 BLDG PRE SLAB 3/10/04 DISAPPROVED TJ REQ COMM: 873-3439 phil RES COMM: vapor barrier not complete, underground plumbing not RES COMM: approved, perimiter insulation has not been inspected, also RES COMM: do not have 8 inch thickened area at perimiter 000 000 BCOM 00 COM BLDG PERMIT P3 0003 BLDG PRE SLAB 3/11/04 CANCELLED TJ REQ COMM: 614-873-3439 000 000 BCOM 00 COM BLDG PERMIT P3 0004 BLDG PRE SLAB 3/15/04 CANCELLED TJ REQ COMM: 873-3439 000 000 BCOM 00 COM BLDG PERMIT P3 0005 BLDG PRE SLAB 3/16/04 APPROVED TJ 000 000 BCOM 00 COM BLDG PERMIT P8 0001 BLDG STRUCTURE/FRAME 4/05/04 DISAPPROVED EL - REQ COMM: phil 873-3439 RES COMM: 1. subcontractor disclosure not completed. RES COMM: 2. no fireblocking installed at vertical/horizontal RES COMM: concealed spaces.(all walls,soffits,dropped ceilings etc.) RES COMM: 3. LVL beam not attached to columns with lag bolts as RES COMM: specified on plan. RES COMM: 4. no draft stop installed in attic space at 3,000 sq.ft. RES COMM: max. 000 000 BCOM 00 COM BLDG PERMIT P39 0001 BLDG STRUCTURAL ABOVE CEI 4/14/04 DISAPPROVED TJ REQ COMM: pls call phil 873-3439 regarding insp RES COMM: see list 000 000 BCOM 00 COM BLDG PERMIT P13 0001 BLDG INSULATION 4/22/04 APPROVED KM REQ COMM: Phil 873-3439 RES COMM: ok to drywall 000 000 BCOM 00 COM BLDG PERMIT P2 0003 BLDG FOOTING 7/02/04 CANCELLED KM REQ COMM: 873-3439 Phil REQ COMM: insp is for light pole bases RES COMM: cancelled- met w/ contractor-heavy water infilltration into RES COMM: 6 foot deep holes,told him to pump out water, pour 2 feet of RES COMM: concrete and push in cages, then complete electrical work, PREPARED 2/22/08, 12:34:48 INSPECTION HISTORY REPORT PAGE 2 PROGRAM BP521L 1/01/03 THRU 0/00/00 CITY OF DUBLIN APPLICATION PROPERTY ADDRESS Parcel Number Alternate Address STRUCTR PERMIT INSPECTION RESULT DATE/STATUS INSPECTOR 03 00200950 CONTINUED RES COMM: set templates, and pour remaining concrete 000 000 BCOM 00 COM BLDG PERMIT P21 0001 BLDG OCCUPANCY 8/05/04 DISAPPROVED TJ RES COMM: see list 000 000 BCOM 00 COM BLDG PERMIT P21 0002 BLDG OCCUPANCY 8/24/04 DISAPPROVED TJ 000 000 BCOM 00 COM BLDG PERMIT P17 0001 ENGINEERING FINAL 8/27/04 DISAPPROVED BJC REQ COMM: 873-3439 RES COMM: Dean Saunders 000 000 BCOM 00 COM BLDG PERMIT P17 0002 ENGINEERING FINAL 9/02/04 DISAPPROVED BJC REQ COMM: 873-3439 Phil 000 000 BCOM 00 COM BLDG PERMIT P9 0001 CURB, WALK & APPROACH 9/18/04 APPROVED JF REQ COMM: 873-3439 000 000 BCOM 00 CON BLDG PERMIT P18 0001 ZONING FINAL 10/04/04 APPROVED WITH EXCEPT BM REQ COMM: 873-3439 phil RES COMM: change out shrubs, relocate a shrub, add 250 min signs at RES COMM: hc, 000 000 BCOM 00 COM BLDG PERMIT P17 0003 ENGINEERING FINAL 10/27/04 DISAPPROVED JF REQ COMM: 873-3439 phil 000 000 BCOM 00 COM BLDG PERMIT P17 0004 ENGINEERING FINAL 11/24/04 CANCELLED JF REQ COMM: pls call 873-3439 b-4 going to insp 000 000 BCOM 00 COM BLDG PERMIT P18 0002 ZONING FINAL 1/04/05 APPROVED BM REQ COMM: 207-2396 phil 000 000 BCOM 00 COM BLDG PERMIT P17 0005 ENGINEERING FINAL 1/13/05 DISAPPROVED JF REQ COMM: 207-2396 phil RES COMM: Original items not addressed RES COMM: Builder in disagreement with Engineering evaluation RES COMM: Pending site visit with Asst. City Engineer 000 000 BOOM 00 COM BLDG PERMIT P17 0006 ENGINEERING FINAL 1/21/05 DISAPPROVED JF REQ COMM: 207-2396 phil 000 000 BCOM 00 COM BLDG PERMIT P17 0007 ENGINEERING FINAL 9/19/05 APPROVED JF REQ COMM: pls call 207-2396 b-4 going out to insp 000 000 CELE 00 COM ELECTRIC SERVICE P4 0001 ELECTRIC UNDERGROUND 3/09/04 APPROVED TZ REQ COMM: 314-2156 RES COMM: Undrslab conduits are ok. 000 000 CELE 00 COM ELECTRIC SERVICE P10 0001 ELECTRIC ROUGH 4/01/04 APPROVED BR RES COMM: Walls ok. 000 000 CELE 00 COM ELECTRIC SERVICE ELSE 0001 ELECTRIC SERVICE 4/20/04 DISAPPROVED BR CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 HOCHSTETLER BUILDINGS, INC. 7927 MEMORIAL DR PLAIN CITY, OH 43064 May 10, 2006 RE: Expired Building Permit Application Number: 03-200950 Address: 6419 OLD AVERY RD Project Description: HILLIARD FURNITURE Dear HOCHSTETLER BUILDINGS, _INC.: The Building Standards Division records indicate that the above-mentioned permit expired and that the project has not received a Final Inspection Approval. In the event that we are in error, please contact this off, ice. inifnediately so that we may amend our files and issue the appropriate Final Approval or Certificate-of Occupancy. If the project has not been completed or simply lacks a final inspection, please call the Inspection Line (614-410-4680) to schedule the final inspections as soon as possible. Please be advised of the following from the Dublin Codified Ordinances: 150.158 FAILURE TO COMPLETE WORK Failure to complete the work authorized by the permit or any extensions thereof shall result in the permit being invalidated and, if any construction has been started and has not been completed, the applicant or owner shall be in violation of the building code. ('80 Code 1341.04)(Ord. 51-82, passed 10-4082) Penalty, see 150.999 Please contact this office immediately (614-410-4670) so that we may assist you in bringing closure to this project. Sincerely, Kevin Moran Acting Director of Building Standards NIXIE 430 1 OO 05/13/06 CC: PROPERTY OWNER RETURN TO SENDER 6419 OLD AVERY RD NOT DEUNABLEDTO FORWARDESSED DUBLIN, OHIO 43016 BC, 43016729$99 *1246-01930-10-95 I,l„1„11,11,,,,,,)1,11„l,,,i,?1,11,1,„I,l,i,l„1,1,,,1,1,1 CITY OF DUBLIN Division of Building Standards * 5800 Shier-Rings Road * Dublin, Ohio 43016 Phone: (614) 410-4670 * Inspection Line: (614) 410-4680 HOCHSTETLER BUILDINGS, INC. 7927 MEMORIAL DR PLAIN CITY, OH 43064 May 10, 2006 RE: Expired Building Permit Application Number: 03-200950 Address: 6419 OLD ARTERY RD Project Description: HILLLA R. D L TURE Dear HOCHSTETLER BUII. DINaGS, INC.: The Building Standards Division records indicate that the above-mentioned permit expired and that the project has not received a Final Inspectifln Approval. In the event that we are in error, please:contact this of ce>iuu ediately so that we may amend our files and issue the appropriate Final Approval or Certificate of Occupancy. If the project has not been completed or simply lacks a final' inspection, please call the Inspection Line (614-410-4680) to schedule the final inspections as soon as possible. Please be advised of the following from the Dublin Codified Ordinances: 150.158 FAILURE TO COMPLETE WORK Failure to complete the work authorized by the permit or any extensions thereof shall result in the permit being invalidated and, if any construction has been started and has not been completed, the applicant or owner shall be in violation of the building code. C80 Code 1341.04)(Ord. 51-82, passed 10-4082) Penalty, see 150.999 Please contact this office immediately (614-410-4670) so that we may assist you in bringing closure to this project. Sincerely, Kevin Moran Acting Director of Building Standards CC: PROPERTY OWNER 6419 OLD AVERY RD DUBLIN, OHIO 43016 CITY OF DUBLIN Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 HOCHSTETLER BUILDINGS, INC. 7927 MEMORIAL DR PLAIN CITY, OH 43064 February 28, 2006 RE: Building Permit Nearing Expiration Application Number: 03-200950 Address: 6419 OLD AVERY RD Project Description: HILLIARD FURNITURE Dear HOCHSTETLER BUILDINGS, INC.: The Building Standards Division records indicate that the above-mentioned permit will expire on March 18, 2006 and that the project has not received a Final Inspection Approval. In the event that we are in error, please contact this office immediately so that we may amend our files and issue the appropriate Final Approval or Certificate of Occupancy. If the project has not been completed or simply lacks a final inspection, please call the Inspection Line (614-410-4680) to schedule the final inspections as soon as possible. If additional time is necessary to complete the project, we will be happy to extend the permit for another six months, if you contact this office prior to permit expiration. There will be a $20.00 fee due at that time. We look forward to hearing from you soon regarding the completion of this project. If we may be of further assistance, please feel free to call our office at (614) 410-4670. Sincerely, Robert K. Price, CBO Director of Building Standards CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Fax: (614) 761-6566 • Inspection Line: (614) 410-4680 DO NOT REMOVE THIS SHEET FROM SITE NOTICE OF INSPECTION Inspection Type_ Application it 0 3 bU9 5 U Date I The undersigned inspectors checked your property at 6L~\O~ 0\6 y t for compliance with Building Code. Any violations listed below must be corrected within days. ki 1 i CA L L f\ i PcPe $ -aLl -O~ I Z_ r?c ~;,,~a1 C~~ J ~t VIOLATIONS 1~ r-- A-3 c A3 F_ F_ A 3 ( 1 2oa ~n f, covm P 1 -4-Dr2 &Yl 1 nr 'PA n~ ya,~t? 1,1 t; A1~G Al ~~C~~.nc~ ~fJ~ Skt\~nr {~~r' ti n~c?~ %,1 Ai 4 LS AJE t=h,~ lt.rn C'CC~'I C; .Qt., At QA3 fif/Jre), tV\k6_~i~t\Q to ~ h 11 { ~CiU. ~S ON ~t1~1 li k r ~o k &W\ 7 Y\ V EW 4 ~"nOk' r- J 0 APPROVED DISAPPROVED By G-'' i - U CONDITIONAL 1 _ CITY OF DUBLIN Ohio 43016 Division of Building Standa58 nspect on'L1neRoad . (614) 41Dublin, 0-4680 Phone: (614) 410-4670 HOCHSTETLER BUILDINGS, INC. 7927 MEMORIAL DR PLAIN CITY, OH 43064 August 31, 2005 RE: Expired Building Permit Application Number: 03-200950 Address: 6419 OLD AVERY RD 'Project Description: HILLIARD FURNITURE Dear HOCHSTETLER BUILDINGS, INC.: The Building Standards Division records indicate that the above-mentioned permit expired and that the project has not received a Final Inspection Approval. In the event that we are in error, please contact this office immediately so that we may amend our files and issue the appropriate Final Approval or Certificate of Occupancy. If the project has not been completed or simply lacks a final inspection, please call the Inspection Line (614-410-4680) to schedule the final inspections as soon as possible. Please be advised of the following from the Dublin Codified Ordinances: 150.158 FAILURE TO COMPLETE WORK Failure to complete the work authorized by the permit or any extensions thereof shall result in the permit being invalidated and, if any construction has been started and has not been completed, the applicant or owner shall be in violation of the building code. C80 Code 1341.04)(Ord. 51-82, passed 10-4082) Penalty, see 150.999 Please contact this office immediately (614-410-4670) so that we may assist you in bringing closure to this project. Sincerely, Robert K. Price, CBO Director of Building Standards CC: PROPERTY OWNER 6419 OLD AVERY RD DUBLIN, OHIO 43016 INSPECTION FORM Department of Development Division of Planning 5800 Shier Rings Dublin, OH 43016 Phone: V/TDD 614/761-6550 Inspection Line: 614/761-6557 CITY OF DUBLIN Fax: 614/761-6556 DO NOT REMOVE THIS SHEET FROM SITE Inspection Type: btj lk& Permit f Y7'~ Property Location: _Iv i T "61 L 1 D'S 1V"Lf lr-4,. Contact Person:- TWO Phone: ?3' Ws ' - Z;7&,,) PLEASE DO NOTNIARK BEIAMIT111S LINE © No Violations/ Inspection Approved ? Violations/ Disapproved `Approved for Conditional Qwvra X Approved I'NG C.9M 1~2 lip-jGlr 1) Site has approved landscape plan and Record of 5) Parking lot screened as per City Code: Action (P&Z): Yes _ No _ Yes No Site lighting installed as per lighting guidelines 6) Parkin area striped; with required number of Yes No spaces: Yes _ No 3) Landscaping installed as per submitted and 7) Handicapped signs M' stalled at designated Approved plan: _ Yes A No parking spaces: _ Y _ No St%tr 6u,- 4) All on-site mechanicals/service structures ~ Landscape mo or parking area, min. 42 Screened as per City Code: X Yes - No (inch) height from finished grade: -Yes _No Comments: Y I NJ- r-lkp- " atT, t fir] ?~.~.;-rr~ _~"'"za,.-~,Y: t t e.~,~t~' ~~..1-~. i"> Contact Building Division at 761-6557 for re-inspection when work has been completed. All work must be completed prior to final inspection for awjj"WF. 7,qqlN& C,,,Mpi . Inspector: - fAn/yW/,t__~ Date: Re-Inspection/Final Approval Inspector: Date: PLA-120 1) WHITE-File 2) GREEN-Bldg. 3) YELLOW-Site 7/01/99' k Division of Building Standards 5800 Shier Rings Road Dublin, Ohio 43016 Phone: VrMD 614/410-4670 7CV11TY OF DUBLIN Inspection Line: 614/410-4680 APPROVAL #3 THIS IS NOT A BUILDING PERMIT. IT IS A RECORD OF OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT. May 24, 2004 RE: HILLIARDS FURNITURE ADDRESS: 6419 Old Avery Road APPLICANT: Joseph P. Borghese, Jack D. Walters & Assoc., Inc. APPLICATION NO.: 03-200950 The plans dated May 17, 2004, for the captioned project have been reviewed for compliance with the provisions of the Ohio Building Code (OBC - January 1, 2002) for the purpose of issuing an APPROVAL. The review was based upon the following criteria: Use Group: M (Furniture Store) Occupancy: 341 @ 30 Sq. Ft./Person, West of Fire Wall Area: 10,228 Sq. Ft., West of Fire Wall Construction Type: VB (No Sprinklers) Automatic Sprinkler: N/A Notes: N/A The architectural plans are sealed by Joseph P. Borghese, Architect #10741, all to comply with the requirements of OBC Section 106.3.4.1 and have been reviewed, therefore, in accord with OBC Section 106.3.1. OBC 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the building official or the building official's designated representative. This APPROVAL does not preclude the acquisition of separate permits for plumbing, mechanical, sprinkler or electric. Permits and fees for these items must be obtained from the Building Division prior to the start of any work in these areas. T:\0FFICE\WP\D0CS\D0C\.lpprova12003\03-200950 Hilliards Furniture 04.524.doc HII.,LIARDS FURNITURE, Applicant: Joseph P. Borghese, Jack D. Walters & Assoc., Inc. Application No. 03-200950 May 24, 2004 Page 2 of 3 Item 1. The size of the neutral conductors shall not be reduced or derated at any point in this system. Mr. Borghese and Mr. Zombek have agreed upon this. The following items are required for code compliance, but are not necessarily covered in detail in the construction documents. This list is a reminder to the design professional and contractors of issues which are to be satisfactorily dealt with in the field. Item 1. OBC 109.2 Lot line markers required. Before any work is started in the construction of a building or an addition to a building to which the rules of the Board are applicable under Section 101.2, all boundary lines shall be clearly marked at their intersections with permanent markers or with markers which are offset at a distance which is of record with the owner. Item 2. OBC 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the building official or the building official's designated representative. Item 3. OBC 105.7.2 Posting. The certificate of plan approval shall be posted in a conspicuous location outside of the building and in the front part of the premises on which is, or will be the approved building or equipment to which the approved plans relate. The owner and the contractor shall, so far as possible, preserve and keep the certificate posted until the completion of the work to which the approved plans relate. Item 4. OBC 106.4 Amended construction documents. If substantive changes to the building are contemplated after first document submission, or during construction, those changes must be submitted to the building official for review and approval prior to those changes being executed. The building official may waive this requirement in the instance of an emergency repair, or similar instance. Item 5. OBC 109.1 General. Construction or work for which an approval is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. This includes firestopping and draftstopping (Chapter 7 OBC), mechanical work; piping, ducts and systems (Chapter 3 OMC), structural members and connections (Chapter 16 OBC), and electrical work (Chapter 27 OBC). All systems and elements covered by code are to be inspected and approved before being covered. Item 6. OBC 1103.1 Where required. Buildings and structures, temporary or permanent, including their associated sites and facilities, shall be accessible to persons with physical disabilities. OBC 1103.2.1 Specific requirements. Accessibility is required in buildings and facilities, or portions thereof, to the extent indicated in ADAAG Section 4.1 and this chapter. Item 7. All electrical will comply with the requirements of Article 27 OBC and the National Electrical Code, NfiPA 70, OBC approved edition and is subject to the approval of the electrical field inspector. T:\OFFICE\WP\DOCS\DOC\Approval 2003\03-200950 Hilliards Furniture 04.524.doc HILLIARDS FURNITURE, Applicant: Joseph P. Borghese, Jack D. Walters & Assoc., Inc. Application No. 03-200950 May 24, 2004 Page 3 of 3 Item 8. The existing electrical conductors, if removed, abandoned, or altered, shall be accomplished to the electrical field inspector's approval. Electrical work found not to meet the code's standards shall be corrected to the electrical field inspector's approval. The start of construction indicates acceptance of all of the conditions listed above. This review does not preclude the necessity to conform with provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rest with the registered design professional, the tenant and the owner. Approval will be valid only upon receipt by the City of Dublin, Division of Building Standards, of one signed copy of this addendum to the submitted plans. TO REQUEST AN APPEAL HEARING, YOU MUST sent a written request, listing the items to be appealed and the relief sought and a copy of this order to: Robert Price, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 Reviewed and Signed, M F. Strayer Robert Price C ercial Plans Exa er Chief Building Official /-/"z If 1 G©---7a4 O r or Owner's R resentative Date JOS #-P k P Un k e s e, Project A rGh;4e-J Print Name and Title '&s Signed T:\OFFICE\WP\DOCS\DOC\Approval 2003\03-200950 Hilliards Fumiture 04.524.doc CITY OF DUBLIN Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 03-00200950 Date 10/31/03 Revision number . . . . . . . 5 Pin number . . . . . . .580650 Special Notes and Comments (DATED 4/11/02) FOR ADDITIONAL CONDITIONS OF APPROVAL. SEE NOTES ON PERMIT SETS. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 TREES SIX INCHES IN CALIPER OR GREATER AT DBH MUST BE PROTECTED PRIOR TO AND DURING ALL PHASES OF CONSTRUCTION - INCLUDING GRADING ACTIVITIES. PROTECT LANDSCAPING AS PER DUBLIN'S LANDSCAPE INSPECTOR AT (614) 410-4660. MAINTAIN/INSTALL PROTECTIVE TREE FENCING DURING ALL PHASES OF CONSTRUCTION Other Fees . . . . . . . . . COM BLDG INSPECT NEW/ADD 760.00 COM CERTIFICATE OF OCC 120.00 SURCHARGE FEE - ELECTRIC 6.90 SURCHARGE FEE - BLDG 45.90 Fee summary Charged Paid Credited Due Permit Fee Total 880.00 .00 .00 880.00 Plan Check Total .00 .00 .00 .00 .Other Fee Total 932.80 .00 .00 932.80 Grand Total 1812.80 .00 .00 1812.80 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. Tb, a ~ ~ Division of Building Standards 5800 Shier Rings Road Dublin, Ohio 43016 Phone: V/TDD 614/410-4670 CITY OF DUBLIN Inspection Line: 614/410-4680 APPROVAL (#2) THIS IS NOT A BUILDING PERMIT. IT IS A RECORD OF OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT. October 13, 2003 RE: HILLIARDS FURNITURE ADDRESS: 6419 Old Avery Road APPLICANT: Joseph P. Borghese, Jack D. Walters & Assoc., Inc. APPLICATION NO.: 03-200950 The plans dated September 25, 2003, for the captioned project have been reviewed for compliance with the provisions of the Ohio Building Code (OBC - January 1, 2002) for the purpose of issuing an APPROVAL. The review was based upon the following criteria: Use Group: M (Furniture Store) Occupancy: 341 @ 30 Sq. FtJPerson, West of Fire Wall Area: 10,228 Sq. Ft., West of Fire Wall Construction Type: VB (No Sprinklers) Automatic Sprinkler: N/A Notes: N/A The architectural plans are sealed by Joseph P. Borghese, Architect #10741, Darcy A. Dom, Engineer #48548 and Zuegang Liu, Engineer #62539 (for trusses), all to comply with the requirements of OBBC Section 4101:2-1-20 and have been reviewed, therefore, in accord with OBBC Section 4101:2-1-22(C). OBC 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the building official or the building official's designated representative. This APPROVAL does not preclude the acquisition of separate permits for plumbing, mechanical, sprinkler or electric. Permits and fees for these items must be obtained from the Building Division prior to the start of any work in these areas. T:\0FFICE\WP\D0CS\D0C\Approva12003\03-200950 Hilliazds Furniture 03.013.doc HILLIARDS FURNITURE, Applicant: Joseph P. Borghese, Jack D. Walters & Assoc., Inc. Application No. 03-200950 October 13, 2003 Page 2 of 3 Item 1. ASHRAE 90.1, Table 403.2.9.2 Minimum insulation on ducts in unheated attic spaces shall be R6.5 or greater. Item 2. OBC 716.4.3 Other groups. Draftstopping shall be installed in attics and concealed roof spaces, such that any horizontal area does not exceed 3,000 square feet (279 m). Item 3. OBC 1003.2.11 Means of egress illumination. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The following items are required for code compliance, but are not necessarily covered in detail in the construction documents. This list is a reminder to the design professional and contractors of issues which are to be satisfactorily dealt with in the field. Item 1. OBC 109.2 Lot line markers required. Before any work is started in the construction of a building or an addition to a building to which the rules of the Board are applicable under Section 101.2, all boundary lines shall be clearly marked at their intersections with permanent markers or with markers which are offset at a distance which is of record with the owner. Item 2. OBC 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the building official or the building official's designated representative. Item 3. OBC 105.7.2 Posting. The certificate of plan approval shall be posted in a conspicuous location outside of the building and in the front part of the premises on which is, or will be the approved building or equipment to which the approved plans relate. The owner and the contractor shall, so far as possible, preserve and keep the certificate posted until the completion of the work to which the approved plans relate. Item 4. OBC 106.4 Amended construction documents. If substantive changes to the building are contemplated after first document submission, or during construction, those changes must be submitted to the building official for review and approval prior to those changes being executed. The building official may waive this requirement in the instance of an emergency repair, or similar instance. Item 5. OBC 109.1 General. Construction or work for which an approval is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. This includes firestopping and draftstopping (Chapter 7 OBC), mechanical work; piping, ducts and systems (Chapter 3 OMC), structural members and connections (Chapter 16 OBC), and electrical work (Chapter 27 OBC). All systems and elements covered by code are to be inspected and approved before being covered. T:\OFFICE\WADOCS\DOC\Approval 2003\03-200950 Hilliards Furniture 03.013.doc HILLIARDS FURNITURE, Applicant: Joseph P. Borghese, Jack D. Walters & Assoc., Inc. Application No. 03-200950 October 13, 2003 Page 3 of 3 Item 6. OBC 1103.1 Where required. Buildings and structures, temporary or permanent, including their associated sites and facilities, shall be accessible to persons with physical disabilities. OBC 1103.2.1 Specific requirements. Accessibility is required in buildings and facilities, or portions thereof, to the extent indicated in ADAAG Section 4.1 and this chapter. Item 7. All electrical will comply with the requirements of Article 27 OBC and the National Electrical Code, NfiPA 70, OBC approved edition and is subject to the approval of the electrical field inspector. Item S. The existing electrical conductors, if removed, abandoned, or altered, shall be accomplished to the electrical field inspector's approval. Electrical work found not to meet the code's standards shall be corrected to the electrical field inspector's approval. The start of construction indicates acceptance of all of the conditions listed above. This review does not preclude the necessity to conform with provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rest with the registered design professional, the tenant and the owner. Approval will be valid only upon receipt by the City of Dublin, Division of Building Standards, of one signed copy of this addendum to the submitted plans. TO REQUEST AN APPEAL HEARING, YOU MUST sent a written request, listing the items to be appealed and the relief sought and a copy of this order to: Robert Price, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 Reviewed and Si e , arti F. Strayer Robert Price Co mercial Plans Exa finer Chief Building Official /10 Nove,.,„1~~, 3 7-o03 O ner or Owner' epresentative Date Joseph P 136r9ko-se., Arc-41+4.1-+ Print Name and Title 'As Signed T:\0FFICE\WP\D0CS\D0C\Approva12003\03-200950 Hilliards Furniture 03.013.doc July 31, 2003 UNIFIED RESPONSE LETTER (URL) Mr. Joseph P. Borghese ..crry OF DUBLIN Jack D. Walters & Associates, Inc. Department of 5166 Blazer Memorial Parkway Development Dublin, OH 43017 5800 Shier Rings Road Dublin, OH 43016-1236 Re: Hilliards Furniture Expansion Phone/7DD:614-410-4600 Dublin Building Permit Application #03-200950 Fax: 614.761.6506 Web Site: www.dublin.oh.us Dear Mr. Borghese: The City of Dublin's Review Services Team has completed review of your application for a Commercial Building Permit submitted July 8, 2003. At this time, the overall status is disapproved and the building permit is denied. The outcome of each review type is shown below with comments in the accompanying plan review letters. Any attachments referenced in the plan review letters will be found with the corresponding set of check prints, which may also contain additional review notes to be addressed. Zoning/Landscape (Z/L) - Disapproved (see attached review letter) Site Engineering (E) - Disapproved (see attached review letter) Building/Structural (S) - Disapproved (see attached review letter) Note the Building plan review letter is not a Building Permit. Please continue to coordinate fire department plan review directly with Captain Alan Perkins, of the Washington Township Fire Department (614-766-0857). Please return the marked-up check prints with a revised resubmittal of four (4) updated and complete plan sets to the Dublin Permit Window (5800 Shier-Rings Road). I am available to handle general review status and procedural questions. Specific technical questions pertaining to plan review letters may be directed to the appropriate Dublin plan reviewer. Our plan reviewers and I can be reached at 614-410-4600. We look forward to receiving your resubmittal responsive to these comments, enabling us to approve the requested permit. Sincerely, fiG Steve A. Snyder, Project Coordinator SAS/df Attachments July 31, 2003 crr~ OF ncact~ Mr. Joseph Borghese Jack D. Walters & Assoc. Inc. Department of 5166 Blazer Memorial Pkw. Development Dublin, OH 43017 5800 Shier Rings Road Dublin, OH 43016.1236 Phone/1DD: 614.410.4600 Fax: 614.161.6506 Web Site: www.dublin.oh.us Re: Zoning Compliance Review Hilliards Furniture 6419 Old Avery Rd. Permit #03-200950 Dear Mr. Borghese: Permit plan sets submitted on July 9`h, 2003 for the above referenced project have been reviewed for Zoning Compliance and are being returned to your attention for revision. For your convenience, this letter is to summarize any and all revisions required for Zoning Plan Approval only. Please review the contents of this letter with all comments shown on the plan set marked "Z" and specific landscape comments shown on the plan set marked "L/E." Please return all plans and related attachments marked "RETURN TO DUBLIN" with vour resubmitted plans in order to expedite the building permit plan review process. General Comments Please coordinate the architect's site plan, utility plan and landscape plan with the engineer's site improvement drawings and the lighting designer's point-by-point drawing. The configuration and information contained on these various sheets must be well coordinated in order to avoid discrepancies in the field. Specific Comments Point-by-Point Drawing 1. Correct parking configuration and confirm placement of pole and wall lights. Heavy up line work to show building and Phase II lot configuration 2. Confirm Proposed light fixture height is 20'-0 above grade maximum. Sheet Cl- Site Plan 1. Label property lines, road center lines (C/L), edge of pavement (E/P), painted lines and setbacks as noted. 2. Label building and dimensions as noted 3. Revise Site Plan/ Zoning Notes as indicated Sheet C3- Landscaping Plan 1. Please include a graphic scale. 2. The spruce proposed along US33 must be at least 3 feet at installation (which they are) and must meet the opacity requirements within four years. Staff believes a single line of evergreens will not achieve the required opacity in that timeframe. Please consider increasing the spacing to 15 feet on-center and using a double staggered row. 3. The proposed burning bush will have to be replaced with an evergreen shrub species. Because of the scope of the proposed expansion exceeds 25% of the original building the Zoning Code requires that the entire site be brought into conformance with the Landscape Code. In addition, the approved development text requires screening to be installed as part of the Phase II development. After rereading the text, Staff believes screening should be extended along the entire southern portion of the site with Phase Il. Future construction of parking in Phase III should not impact the plant material if protective tree fencing is installed prior to and maintained throughout all construction. If development of Phase III never occurs, portions of the parking lot installed during Phase II will be left unscreened and will not be in compliance with code. If you have questions concerning the required changes to the landscape plan, please contact Mary Newcomb, Senior Planner at 410-4665. These revisions must be coordinated with any and all plan review comments identified in the structural and engineering plan reviews, as well as the comments of the Washington Township Fire Department. If you have any questions about this review for Zoning Plan Approval, please do not hesitate to call me at 410- 4664. 1 look forward to hearing from you. Sincerely, Dave Marshall Development Review Specialist DM/df S\Review Services\Dave Division of Engineering 5800 Shier-Rings Road Dublin, Ohio 43016-1236 CITY OF DUBLIN Phone: 614-410-4600 Fax: 614-718-4346 To: Joe Borghese - Jack D. Walters & Associates, Inc. From: Kristin K. Yorko, P.E., Civil Engineer Date: July 31, 2003 Re: Hilliards Furniture Addition - Plan Review Comments 03-001-COM We have reviewed the plan submission made by your office on July 9, 2003, for this project. The attached red-lined prints should also be reviewed by your office as they support the following written comments: General Comments • The site improvement drawings are required in a particular format. They have not been submitted as requested. Please provide the site plans as required per the attached checklist. • The Site Improvement Plans will be required to be submitted on 24 by 36-inch 4-mil mylars and in electronic format compatible with AutoCAD once final approval is given. • The stamp and signature of the design professional that prepared drawings will be needed on the final Mylar. • Show the intersection visibility triangles at the proposed driveways per Administrative Policy 95-013. Use a stop sign controlled intersection. • Verify that the proposed grading within the triangles meets the guidelines. • Provided additional spot grades for the handicap spaces to ensure that no grades are greater than 2% in any direction. • Proof that the private waste disposal system meets the requirements of Section 51.02 and that evidence of appoval of the private waste disposal system by the OEPA and Franklin County Board of Health be provided prior to the issuance of a building permit. Bird and Bull Plans Sheet 1 of 4 • Include fax number of owner. Sheet 2 of 4 • Headwalls are required in City of Dublin (COD). Detail okay, change call out in profile. • Need a cross-section of pond, side slopes look okay. • Need elevations of Benchmarks and to show existing contours with smaller dashes. • Need detail of catch basin with orifice. • Water quality table size shown different than calculations. • Will rock channel protection type C work? Would prefer smaller rock. • Are there only two trees on the property? Will these be preserved? Sheet 3 of 4 • Remove all references to straw bales. • Install tree protection fence should be number one on Construction Sequence. • Include IPP in your Construction Sequence. N:\EG\PERSONAL\KRISTIN\COMMERCIAL\03001 COM HILLIARDS.DOC Pagel of2 Stormwater Management Plan • See comments in the plan Jack D. Walters & Associates, Inc. Plans Cover Page • City Engineer will only sign one set of drawings, please see note above and revise plans. Staking Plan (Cl) • Indicate sidewalk width. • All Civil drawings need to match. • For Public roads, you need to indicate Right-of-way width, centerline of pavement (not necessary for SR 33), edge of pavement (not necessary for SR 33), and location and type of curb (not necessary for SR 33). • Include a note on the drawing that the entrance drive (for the customer parking are) will be installed per City of Dublin Standard Drawing 603.1-96 and must also be inspected. (A copy of which is attached for your reference.) • Indicate where dimensions are taken from, ie. edge of pavement, face of curb. Utility Plan (C2) • Where are the existing trees? What is your tree protection plan? • Gas lines are shown incorrectly, you can not have medium pressure and high pressure combined into one line. This is not an issue for City of Dublin, but you will want to make sure your contractor is extremely careful in this area. • Add note that the private wastewater system details are for information only and that the OEPA approved drawings shall be utilized for construction. • Be advised that a right of way permit from ODOT will be needed for the work within the S.R. 33 right of way. If you have any questions regarding these comments, please contact us. N:\EG\PERSONAL\KRISTMCOMMERCIAL\03001 COM HILLIARDS.DOC Page 2 Of 2 Division of Building Standards 5800 Shier Rings Road Dublin, Ohio 43016 Phone: V/TDD 614/410-4670 1 Inspection Line: 614/410-4680 CORRECTION REQUEST THIS IS NOT A BUILDING PERMIT. IT IS A RECORD OF OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT. July 18, 2003 RE: HILLIARDS FURNITURE 6419 Old Avery Road APPLICANT: Joseph P. Borghese, Jack D. Walters & Assoc., Inc. APPLICATION NO: 03-200950 The plans are sealed by Joseph P. Borghese, Architect #10741, Darcy A. Dom, Engineer #48548 and Zuegang Lie, Engineer #62539 (for trusses) all to comply with the requirements of the Ohio Building Code, (OBC - January 1, 2002). The review was based upon the following criteria. Use Group: M (Furniture Store) Occupancy: 341 @ 30 Sq. Ft./Person, West of Fire Wall Area: 10,228 Sq. Ft., West of Fire Wall Construction Type: VB (No Sprinklers) OBC 106.3 Examination of documents. The building official shall examine or cause to be examined the accompanying construction documents and shall ascertain by such examinations whether the construction indicated and described is in accordance with the requirements of this code. The construction documents, which have been submitted, do not allow the City of Dublin to issue a permit to begin construction. Substantial portions of the OBC have not been complied with, as indicated by the following items. The following item(s) shall be brought into full conformance with the OBC prior to the issuance of any partial or conditional plan approval. T:\OFFICE\WP\DOCS\DOC\Ccrrection Request 2003\03-200950 Hilliards Fumiture doc HILLIARDS FURNITURE, Joseph P. Borghese, Jack D. Walters & Assoc., Inc., Application No. 03-200950 July 18, 2003 Page 2 of 3 Item 1. The addition, plus the existing space west of the fire wall, is 10,228 square feet. The base allowance from Table 503 is 9,000 sq. ft./one story. The bulling is open for firefighting on the south and west sides, so the additional 25% allowance permits this "building" to be 1.25x 9,000 =11,250 sq. ft., which is greater than the 10,228 actual square footage. Item 2. Coordinate the location of the notifiersignals for the smoke detectors with the Building and Fire Inspectors. Item 3. The double doors on the east side of the building are to remain unblocked during business hours when customers are in the mercantile space. Item 4. The owner is to provide an affidavit of flame spread and smoke contributed for the carpet, to the Field Inspector, before it is installed. Item 5. NEC 250-116. Nonelectric Equipment. The metal parts of non-electric equipment described in this section shall be grounded. (1) Frames and tracks of electrically operated cranes and hoists (2) Frames of nonelectrically driven elevator cars to which electric conductors are attached (3) Hand-operated metal shifting ropes or cables of electric elevators FPN: Where extensive metal in or on buildings may become energized and is subject to personal contact, adequate bonding and grounding will provide additional safety. Item 6. Provide the following electrical information: (1) Provide available fault current to show that the existing 200 a service is properly protected. (2) Provide load calculations to show that the existing 200 a panel is not overloaded. (3) Connected load of the new 200 a disconnect exceeds 80% of it's capacity (160 amp maximum permitted load). (4) Identify conductor type. (5) Identify wiring method and material. (6) Provide wireway size. (7) All ground rods must be bonded together. (8) Provide voltage drop calculations (ASHRAE is 2% maximum). TAOFF[CE\WP\DOCS\DOC\on Request 2003\03-20090 Hilliards Fumiture.doc \I~II11~~1 w HILLIARDS FURNITURE, Joseph P. Borghese, Jack D. Walters & Assoc., Inc., Application No. 03-200950 July 18, 2003 Page 3 of 3 This review does not preclude the necessity to conform with provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rest with the registered design professional, the tenant and the owner. This review is based upon the information contained within the submitted drawings and related documents. Once corrections are made, submit four (4) complete sets of plans to the City of Dublin, Division of Building Standards. TO REQUEST AN APPEAL HEARING, YOU MUST sent a written request, listing the items to be appealed and the relief sought and a copy of this order to: Robert Price, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 Reviewed and Signed, VornmeMm . Str ayer, IA Robert Price rcial Plans xa ner Chief Building Official Signature - Architect, Engineer or Contractor Date (Optional) Print Name and Title as Signed T:\OFFICE\WP\DOCS\DOC\Cc rection Request 2003\03 200950 Hilliards Fumituredoe N IES • WASHINGTON ToNvNSHIP FIRE DEPARTNIENT 6279 Shier Rings Road ~'~'•F.;NKL" Dublin, Ohio 43016-1294 oil 614-889-2347 • Fax 614-766-2507 DATE. July 24, 2003 TO: Bob Price, CBO Division of Building Standards City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 ATTN: Martin Strayer, Commercial Plan Reviewer RE: Washington Township's Fire Department Plan Review PERMIT 03-200950 PROJECT: Halliards Furniture Retail Addition LOCATION: 6419 Old Avery Road RECEIVED: Jul 08 2003 Mr. Strayer: We have reviewed the plans for the referenced project dated 7/07/03, submitted to the Division of Building Standards Jul 08 2003, for matters of concern to the Washington Township Fire Department regarding rules of the 2002 Ohio Building Code relating to fire prevention and the Dublin Fire Code(DFC) based upon the 2000 International Fire Code. We are able to recommend approval of the drawings with the following condition(s): Item 1. OBC 1003.2.11 Means of egress illumination. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. a. Please require that the newly created exit discharge from the existing Storage/Stock Room be illuminated and e confirm that the existing exit discharges are properly illuminated. Thank you for the opportunity to review the submission. Please feel free to call with any questions. W S NGTON TOWNSHIP FIRE DEPARTMENT Ray M. H rpham, Architect/Plans Examiner Captain Alan Perkins Fire Prevention (614) 488-4009 Division Commander 614-798-2200 ext 102 cc: Joseph P. Borghese bt-Tlan Reiev.4Washington Ul)%Acviews 004403-300950 ca COO.wpd Trustees: Michael Ft. Keenan • Denise King • Ruth N1. Reis% Clerk/Tre-murer: Joyce E. Robinson Administrator. Tom Spring Chief. Alhin WOO 1-d SOOtF 88t, t119 i ajnioaq r goje dEE : b0 EO *2 T nr 00, October 16, 2003 f.n UNIFIED RESPONSE LETTER (URL) J IT) OF M i,1J\ Department of Mr. Joseph P. Borghese Development Jack D. Walters & Associates, Inc. 5800 Shier Rings Road 5166 Blazer Memorial Parkwa Dublin, OH 43016-1136 y Dublin, OH 43017 Phone/TDD: 614.410-4600 Fax: 614-761-6506 Web Site: : www.dublin.oh.us Re: Hilliards Furniture Expansion Dublin Building Permit Application #03-200950 Dear Mr. Borghese, The City of Dublin's Review Services Team has completed plan review of your application for a Commercial Building Permit submitted September 25, 2003. At this time, the overall status remains disapproved and the building permit is denied. Our Zoning and Engineering plan reviews are substantially complete and generally favorable. Note the Building Standards Division plan review letter previously forwarded to you is not a Building Permit. As relayed to you in previous correspondence, evidence of approval by the Ohio Environmental Protection Agency (OEPA) for the project's wastewater treatment and disposal plans is needed prior to Zoning and Engineering endorsement of a building permit. We will hold the project plans in our Review Services area pending resolution of the outstanding OEPA issue. Once OEPA has satisfied our Zoning and Engineering staff concerning the wastewater treatment and disposal system we will reactivate the review process and work to assemble approved plan sets for return to our Building Standards Division for out-processing and issuance of permit as quickly as possible. Sincerely, Steve A. Snyder, P.E. Project Coordinator SAS/df iowt t r September 17, 2003 UNIFIED RESPONSE LETTER (URL) .CITE OF DUBLIN Mr. Joseph P. Borghese Jack D. Walters & Associates, Inc. Department 5166 Blazer Memorial Parkway Development t 5800 Shier Rings Road Dublin, OH 43017 Dublin, OH 43016-1236 Phone/IDD:614-410-4600 Re: Hilliards Furniture Expansion Fax: 614-161.6506 Dublin Building Permit Application #03-200950 Web Site: www.dublin.oh.us Dear Mr. Borghese: The City of Dublin's Review Services Team has completed review of your application for a Commercial Building Permit submitted July 8, 2003. At this time, the overall status is disapproved and the building permit is denied. The outcome of each review type is shown below with comments in the accompanying plan review letters. Any attachments referenced in the plan review letters will be found with the corresponding set of check prints, which may also contain additional review notes to be addressed. Zoning/Landscape (Z/L) - Disapproved (see attached review letter) Site Engineering (E) - Disapproved (see attached review letter) Building/Structural (S) - approved Note the Building plan review letter is not a Building Permit. Please continue to coordinate fire department plan review directly with Captain Alan Perkins, of the Washington Township Fire Department (614-766-0857). Please return the marked-up check prints with a revised resubmittal of four (4) updated and complete plan sets to the Dublin Permit Window (5800 Shier-Rings Road). I am available to handle general review status and procedural questions. Specific technical questions pertaining to plan review letters may be directed to the appropriate Dublin plan reviewer. Our plan reviewers and I can be reached at 614-410-4600. We look forward to receiving your resubmittal responsive to these comments, enabling us to approve the requested permit. Sincerely, i Steve A. Snyder, P. . Project Coordinator SAS/df Attachments S September 17, 2003 -CITY OF DUBLIN Mr. Joseph Borghese Jack D. Walters & Assoc. Inc. Department of 5166 Blazer Memorial Pkw. Development Dublin, OH 43017 5800 Shier Rings Road Dublin, OH 43016.1236 Phone/rDD: 614-410-4600 Re: Zoning Compliance Review . Fax: 614-761-6506 Hilliard's Furniture Web Site: www.dublin.oh.us 6419 Old Avery Rd. Permit #03-200950 Dear Mr. Borghese: Permit plan sets submitted on August 19, 2003, for the above referenced project have been reviewed for Zoning Compliance. For your convenience, this letter is to summarize any and all revisions required for Zoning Plan Approval only. Please review the contents of this letter with any comments shown on the plan set marked "L/E." Please return these plans and anv related attachments marked "RETURN TO CITY OF DUBLIN" with your revised site improvement drawings in order to expedite the final approval of the building permit General Comments All previously requested plan revisions required for zoning compliance have been made to the plans. However, Condition #6 of the Planning and Zoning Commission Record of Action dated (April 17, 2003) requires evidence of OEPA and Franklin County Board of Health approval of the private waste disposal system before building permits can be issued. According to the Division of Engineering this condition has not been satisfied as of this date. All revisions requested by the Division of Engineering must be coordinated with any and all plan review comments required by the Washington Township Fire Department, if any. If you have any questions about this review for Zoning Plan Approval, please do not hesitate to call me at 410-4664. I look forward to hearing from you. Sincerely, Dave Marshall Development Review Specialist DM/df S\Review Services\Dave\Hilliards Furniture 91703 Division of Engineering 5800 Shier-Rings Road Dublin, Ohio 43016-1236 CITY OF DUBLIN Phone: 614-410-4600 Fax: 614-718-4346 To: Joe Borghese - Jack D. Walters & Associates, Inc. From: Kristin K. Yorko, P.E., Civil Engineern Date: August 12, 2003 Re: Hilliards Furniture Addition - Plan Review Comments 03-001-COM We have reviewed the plan submission made by your office on August 19, 2003, for this project. The attached red- lined prints should also be reviewed by your office as they support the following written comments: General Comments 4 The Site Improvement Plans will be required to be submitted on 24 by 36-inch 4-mil mylars and in electronic format compatible with AutoCAD once final approval is given. • The stamp and signature of the design professional that prepared drawings will be needed on the final Mylar. • Proof that the private waste disposal system meets the requirements of Section 51.02 and that evidence of appoval of the private waste disposal system by the OEPA and Franklin County Board of Health be provided prior to the issuance of a building permit. City of Dublin had a conversation with OEPA and understands that they are awaiting corrected plans. Once OEPA receives approvable plans, we can move forward with the building permit process. Jack D. Walters & Associates, Inc. Plans • Page 5/6 For Public roads, you need to indicate Right-of-way width. • Page 6/6 Floor elevation does not match the other Civil Plans. • Page 6/6 Show tree protection fencing. If you have any questions regarding these comments, please contact us. N:\EG\PERSONAL\KRISTIN\COMMERCIAL\03001COMHILLIARDS.DOC Page 1 of 1 ' Division of Building Standards 5800 Shier Rings Road Dublin, Ohio 43016 Phone: V/TDD 614/410-4670 CITY OF DUBLIN Inspection Line: 614/410-4680 APPROVAL THIS IS NOT A BUILDING PERMIT. IT IS A RECORD OF OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT. September 2, 2003 RE: HILLIARDS FURNITURE ADDRESS: 6419 Old Avery Road APPLICANT: Joseph P. Borghese, Jack D. Walters & Assoc., Inc. APPLICATION NO.: 03-200950 The plans dated August 19, 2003, for the captioned project have been reviewed for compliance with the provisions of the Ohio Building Code (OBC - January 1, 2002) for the purpose of issuing an APPROVAL. The review was based upon the following criteria: Use Group: M (Furniture Store) Occupancy: 341 @ 30 Sq. Ft./Person, West of Fire Wall Area: 10,228 Sq. Ft., West of Fire Wall Construction Type: VB (No Sprinklers) Automatic Sprinkler: N/A Notes: N/A The architectural plans are sealed by Joseph P. Borghese, Architect #10741, Darcy A. Dom, Engineer #48548 and Zuegang Lib,- Engineer #62539 (for trusses), all to comply with the requirements of OBBC Section 4101:2-1-20 and have been reviewed, therefore, in accord with OBBC Section 4101:2-1-22(C). OBC 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the building official or the building official's designated representative. This APPROVAL does not preclude the acquisition of separate permits for plumbing, mechanical, sprinkler or electric. Permits and fees for these items must be obtained from the Building Division prior to the start of any work in these areas. T:\OFFICE\wP\DOCS\DOC\Approva12003\03-200950 Hilliards Furniture.doc HILLIARDS FURNITURE, Applicant: Joseph P. Borghese, Jack D. Walters & Assoc., Inc. Application No. 03-200950 September 2, 2003 Item 1. ASHRAE 90.1, Table 403.2.9.2 Minimum insulation on ducts in unheated attic spaces shall be R6.5 or greater. Item 2. OBC 716.4.3 Other groups. Draftstopping shall be installed in attics and concealed roof spaces, such that any horizontal area does not exceed 3,000 square feet (279 m). Item 3. OBC 1003.2.11 Means of egress illumination. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. Item 4. The letter from architect Joseph Borghese, dated August 19 is a part of this Plan Approval. Item 5. The response on Sheet A5 addresses the questions raised by the Electrical Inspector earlier. The following items are required for code compliance, but are not necessarily covered in detail in the construction documents. This list is a reminder to the design professional and contractors of issues which are to be satisfactorily dealt with in the field. Item 1. OBC 109.2 Lot line markers required. Before any work is started in the construction of a building or an addition to a building to which the rules of the Board are applicable under Section 101.2, all boundary lines shall be clearly marked at their intersections with permanent markers or with markers which are offset at a distance which is of record with the owner. Item 2. OBC 106.3.1 Approval of construction documents. When the construction documents have been determined to conform to the applicable provisions of the rules of the Board in accordance with the procedures set forth in Section 105.3.1, the building official shall endorse or stamp such plans as approved. One set of construction documents shall be kept by the building official. The other set(s) shall be returned to the applicant, kept at the work site and shall be open for inspection by the building official or the building official's designated representative. Item 3. OBC 105.7.2 Posting. The certificate of plan approval shall be posted in a conspicuous location outside of the building and in the front part of the premises on which is, or will be the approved building or equipment to which the approved plans relate. The owner and the contractor shall, so far as possible, preserve and keep the certificate posted until the completion of the work to which the approved plans relate. Item 4. OBC 106.4 Amended construction documents. If substantive changes to the building are contemplated after first document submission, or during construction, those changes must be submitted to the building official for review and approval prior to those changes being executed. The building official may waive this requirement in the instance of an emergency repair, or similar instance. T:\OFFICE\WP\DOCS\DOC\Approval 2003\03-200950 Hilliards Furniture.doc HILLIARDS FURNITURE, Applicant: Joseph P. Borghese, Jack D. Walters & Assoc., Inc. Application No. 03-200950 September 2, 2003 Item 5. OBC 109.1 General. Construction or work for which an approval is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. This includes fzrestopping and draftstopping (Chapter 7 OBC), mechanical work; piping, ducts and systems (Chapter 3 OMC), structural members and connections (Chapter 16 OBC), and electrical work (Chapter 27 OBC). All systems and elements covered by code are to be inspected and approved before being covered. Item 6. OBC 1103.1 Where required. Buildings and structures, temporary or permanent, including their associated sites and facilities, shall be accessible to persons with physical disabilities. OBC 1103.2.1 Specific requirements. Accessibility is required in buildings and facilities, or portions thereof, to the extent indicated in ADAAG Section 4.1 and this chapter. Item 7. All electrical will comply with the requirements of Article 27 OBC and the National Electrical Code, NfiPA 70, OBC approved edition and is subject to the approval of the electrical field inspector. Item 8. The existing electrical conductors, if removed, abandoned, or altered, shall be accomplished to the electrical field inspector's approval. Electrical work found not to meet the code's standards shall be corrected to the electrical field inspector's approval. The start of construction indicates acceptance of all of the conditions listed above. This review does not preclude the necessity to conform with provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rest with the registered design professional, the tenant and the owner. Approval will be valid only upon receipt by the City of Dublin, Division of Building Standards, of one signed copy of this addendum to the submitted plans. TO REQUEST AN APPEAL HEARING, YOU MUST sent a written request, listing the items to be appealed and the relief sought and a copy of this order to: Robert Price, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 Reviewed and Signed, in F. Strayer Robert Price C mmercial Plans Examiner Chief Building Official Owner or Owner's Representative Date Print Name and Title as Signed T:\OFFICE\WP\DOCS\DOC\Approval 2003\03-200950 Hilliards Fumiture.doc • NTIES WASHINGTON TOWNSHIP Gpu pF FIRE DEPARTMENT 6279 Shier Rings Road RANK ~~N' ° Dublin, Ohio 43016-1294 ' 614-889-2347 • Fax 614-766-2507 ° DATE: October 7, 2003 O TO: Bob Price, CBO Division of Building Standards City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 ATTN: Martin Strayer, Commercial Plan Reviewer RE: Washington Township's Fire Department Plan Review PERMIT 03-200950(3) PROJECT: Milliards Furniture Retail Addition LOCATION: 6419 Old Avery Road RECEIVED: Sep 25 2003 Mr. Strayer: We have reviewed the plans for the referenced project dated 7/07/03, revised 8/15/03 and 9/25/03 submitted to the Division of Building Standards Sep 25 2003, fer matters of concern to the Washington Township Fire Department regarding rules of the 2002 Ohio Building Code relating to fire prevention and the Dublin Fire Code(DFC) based upon the 2000 International Fire Code. There have been no revisions that require our changing our previous recommendations for approval. Thank you for the opportunity to review the submission. Please feel free to call with any questions. AS GTON TO SHIP FIRE DEPARTMENT I ~4 i; Ray M. ham, Archi lans Examiner Captain Alan Perkins Fire Prevention (614) 48811009 Division Commander 614-798-2200 ext 102 M:W1n_Reviews%Was6kWw_TwpVteviews034 -200950(3) aCBO.wpd Trustees: Michael H. Keenan • Denise King • Ruth M. Reiss Clerk/Treasurer: Joyce E. Robinson Administrator: Tom Spring Chief: Allan Woo • TIES WASHINGTON TOWNSHIP COUN OF FIRE DEPARTMENT 6279 Shier Rings Road • FWRAN Dublin, Ohio 43016-1294 614-889-2347 - Fax 614-766-2507 DATE: September 3, 2003 TO: Bob Price, CBO Division of Building Standards City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 ATTN: Martin Strayer, Commercial Plan Reviewer RE: Washington Township's Fire Department Plan Review PERMIT 03-200950(2) PROJECT: Hilliards Furniture Retail Addition LOCATION: 6419 Old Avery Road RECEIVED: Aug 19 2003 Mr. Strayer: We have reviewed the plans for the referenced project dated 7/07/03, revised 8/15/03 and submitted to the Division of Building Standards Aug 19 2003, for matters of concern to the Washington Township Fire Department regarding rules of the 2002 Ohio Building Code relating to fire prevention and the Dublin Fire Code(DFC) based upon the 2000 International Fire Code. We are able to recommend approval of the drawings as submittedy illuminated. Thank you for the opportunity to review the submission. Please feel free to call with any questions. WASHINGTON TOWNSHIP FIRE DEPARTMENT a& &GW Ray M. Harpham, Architect/Plans Examiner Captain Alan Perkins Fire Prevention (614) 4884009 Division Commander 614-798-2200 ext102 M:\Plan_Reviews\Wast imstm_TWp\Reviews 03-04\03-200950(2) a CDO.wpd . Trustees: Michael H. Keenan - Denise King - Ruth M. Reiss Clerk/Treasurer: Joyce E. Robinson Administrator: Tom Spring Chief: Allan Woo 4 LauNTIFS • WASHINGTON TOWNSHIP FIRE DEPARTMENT 6279 Shier Rings Road q,F'F•""K`~ Dublin, Ohio 43016-1294 614-889-2347 • Fax 614-766-2507 Date: /(4 4oa3 - To: Bob Price, Director City of Dublin Division of Building Standards i 5800 Shier Rings Road Dublin, Ohio 43016 Re: Washington Township's Fire Department Plan Review Permit o3-,A009sn Project: !f~ %/iarr./s Furn~ lure {gkrsf ewafP~ ~r i~aent ~o t) Location: 6 V 19 Old Avery Rd. Received: 43 Ju 14 A o6-3 Review Comments: 4 Rioyed wlM ny 6% OP,ogr>`mPn f ComMF r& ~sP I IF Reviewed By: C.OA l 0'e-V C~f •6" Trustees: Michael H. Keenan • Denise King • Ruth M. Reiss Clerk/Treasurer: Joyce E. Robinson Administrator: Tom Spring Chief: Allan Woo D L0UNTIES0, WASHINGTON TOWNSHIP FIRE DEPARTMENT 6279 Shier Rings Road 9RF'FRANK~>N Dublin, Ohio 43016-1294 614-889-2347 • Fax 614-766-2507 DATE: July 24, 2003 TO: Bob Price, CBO Division of Building Standards City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 ATTN: Martin Strayer, Commercial Plan Reviewer RE: Washington Township's Fire Department Plan Review PERMIT 03-200950 PROJECT: Billiards Furniture Retail Addition LOCATION: 6419 Old Avery Road RECEIVED: Jul 08 2003 Mr. Strayer: We have reviewed the plans for the referenced project dated 7/07/03, submitted to the Division of Building Standards Jul 08 2003, for matters of concern to the Washington Township Fire Department regarding rules of the 2002 Ohio Building Code relating to fire prevention and the Dublin Fire Code(DFC) based upon the 2000 International Fire Code. We are able to recommend approval of the drawings with the following condition(s): Item 1. OBC 1003.2.11 Means of egress illumination. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. a. Please require that the newly created exit discharge from the existing Storage/Stock Room be illuminated and confirm that the existing exit discharges are properly illuminated Thank you for the opportunity to review the submission. Please feel free to call with any questions. W S GTON TOWNSHIP FIRE DEPARTMENT ~j~ /6&- Ray M. ham, , Architect/Plans Examiner Captain Alan Perkins Fire Prevention (614) 488-4009 Division Commander 614-798-2200 ext 102 cc: Joseph P. Borghese M\Plan_Reviews\Washingwin_TWp\Beviem 03.04\03-200950 ca CBO.wpd Trustees: Michael H. Keenan • Denise King • Ruth M. Reiss Clerk/Treasurer. Joyce E. Robinson Administrator: Tom Spring Chief. Allan Woo RECEIVED AUG 1 9 2003 BUILDING DIVISION JACK D. WALTERS & ASSOCIATES, INC. CITY OF DUBLIN P.O. BOX 855 7265 INDUSTRIAL PARKWAY PLAIN CITY, OHIO 43064 DUBLIN, OHIO 43017 .,77, .7 ARCHITECTS & August 19, 2003 ENGINEERS City of Dublin Department of Development 5800 Shier Rings Road Dublin, Ohio 43016-1236 Attn: Steve A. Snyder, P.E., Project Coordinator Re: Uniform Response Letter (URL) Hilliards Furniture, Retail Addition; Permit Application #03-200950 We have reviewed the Unified Response Letter dated July 31, 2003 and the reviewed drawings and have the following responses. The following items are listed in the same order as in the URL and have been separated by review category. 1. Zoning Compliance Review. A. General Comments: Discrepancies between the architect plans, the engineer's site improvement drawings, and the lighting designer's point by point analysis have been corrected: refer to the revised drawings. B. Sheet C1- Site Plan: Site plan has been revised as marked: refer to revised drawing. The difference between the square footages on the Architectural Cover Sheet General Notes and the numbers on approved by the Planning Commission is accounted for by the inclusion of covered porch/entry, which was not listed in the Planning Commission square footages but is now required by the 2002 Ohio Building Code (OBC). C. Sheet C3- Landscaping Plan: 1. Graphic Scale has been added. 2. Density of Spruce plantings has been increased as requested, with (2) rows of green spruce 15' on center staggered by 3', for an actual tree to tree spacing of 8', increasing the number of these trees from 40 to 53. 3. The proposed Burning Bushes along the south property line have been re-specified as evergreen densiform yew bushes. 4. Per our meeting with Barbara Clarke and Mary Newcombe on 8/08/03, the screening plantings along the south property line are to remain as submitted. Additional plantings are at West and East Portions of South Property line are to be included with the Phase III parking development in these areas. II. Division of Engineering Review. A. General Comments: 1. Format has been revised so that all the Civil division drawings are in the same package. 2. The Site Improvement Plans will be submitted on 24 X 36 4-mil mylars and in electronic format after final approval is given. The stamp and signature of the design professional will be / provided on the final Mylar. B' Intersection visibility triangles are shown at the proposed driveway, based on one-way stop controlled intersection, 20' wide main street at 25 mph. See Staking Plan C5/6. Private disposal system; the private waste disposal system was designed based on requirements of the Franklin Co. Board of Health and is currently being reviewed for approval by OEPA. We will copy Dublin with OEPA approval as soon as it is received. 614/873-4902 FAX 614/873-627 idwae@email.msn.com B. Bird and Bull Plans, Stormwater Management Report: Corrections made by Bird and Bull: refer to revised plans. C~JDW Cover Page: Format has been revised so that Civil drawings are in the same package, with the signature line on first sheet of Bird and Bull drawings. D. JQW Staking Plan (Re-formatted as C5 of 6): p/ Sidewalk width is 3'-0"; revised on drawings. Civil drawings have been revised to match pavement layout. ® Public road notation revised: see A/C5-6.-To VZOW ki41kn.1 Entrance drive has been noted to comply with Dublin Standard Drawing 603.1-96. Dimensions are taken from edge of pavement unless noted otherwise. Dimensions at curbs have been noted. E. -Utility Plan: 1. Only trees to remain exist on Route 33 fence line: Tree protection is shown on the Landscape Plan. 2. Gas Lines are shown based on available information. Plans have been noted for Contractor to contact the Utility Companies and the Ohio Utilities Protection Service prior to site work. Private wastewater note has been added to the drawing. A separate permit (06-0786-03) has been obtained for the work within the ODOT jurisdiction. III. Division of Building Standards Correction Request. A. Item 1: General notes have been revised to show open perimeter allowance as calculated. B. Item 2: Coordination Note for smoke detector notifier has been added to Mechanical, Electrical Plans. C. Item 3: Double doors on the East side of the building are to remain unblocked during business hours, refer to floor plan A/A1. D. Item 4: Floor finish fire spread: note added to drawing A/A1. E. Item 5: NEC 250-116, non-electric equipment. Existing Building and proposed building does not contain items listed. Electrical drawing A/A5 has been revised to provide for grounding of metal building wall panels. F. Item 6: Additional electrical information requested has been added to Electrical plan A5. Please feel free to contact our office if you have any questions or require any additional information. Very truly yours, Joseph P. Borghese, Ar itect Jack D. Walters & Associates, Inc JDW #011-02.1 ENC: (4) sets revised including revised drawing sheets. (4) sets revised pt by pt lighting design Original submittal sets, Red marked by Dublin Copy, Unified Response Letter #1 Dated July 31, 2003 -2- Sir4 + Rill HILLIARDS FURNITURE ADDITION RESPONSE TO REVIEW COMMENTS Sheet 1 The fax nu/iber has been added to the plan. Sheet 2 The endwalls b(ave been changed to headwalls in the profile. A cross- sectios(of the basin has been added to the plans. The elevations/of the Benchmarks have been added. The existing cq/ltours have been shown with smaller dashes. An orifice plan*tail has been added to the plans. The Water Quality Table has been corrected. The rock channotprotection has been changed to type "C". The two trees will be preserved. The water velocity from the basin and the frequency that the overflow is used should not damage the trees. Sheet 3 All references tp~s aw bales have removed. Tree protection been added as the first step in the Construction Sequence. IPP has been addid to the Construction Sequence. Division of Building Standards 5800 Shier Rings Road Dublin, Ohio 43016 Phone: V/'I DD 614/410-4670 701TY OF DUBLIN Inspection Line: 614/410-4680 CORRECTION REQUEST THIS IS NOT A BUILDING PERMIT. IT IS A RECORD OF OUR REVIEW OF DOCUMENTS SUBMITTED WITH YOUR APPLICATION FOR A BUILDING PERMIT. July 18, 2003 RE: HILLIARDS FURNITURE 6419 Old Avery Road APPLICANT: Joseph P. Borghese, Jack D. Walters & Assoc., Inc. APPLICATION NO: 03-200950 The plans are sealed by Joseph P. Borghese, Architect #10741, Darcy A. Dom, Engineer #48548 and Zuegang Lie, Engineer #62539 (for trusses) all to comply with the requirements of the Ohio Building Code, (OBC - January 1, 2002). The review was based upon the following criteria. Use Group: M (Furniture Store) Occupancy: 341 @ 30 Sq. Ft./Person, West of Fire Wall Area: 10,228 Sq. Ft., West of Fire Wall Construction Type: VB (No Sprinklers) OBC 106.3 Examination of documents. The building official shall examine or cause to be examined the accompanying construction documents and shall ascertain by such examinations whether the construction indicated and described is in accordance with the requirements of this code. The construction documents, which have been submitted, do not allow the City of Dublin to issue a permit to begin construction. Substantial portions of the OBC have not been complied with, as indicated by the following items. The following item(s) shall be brought into full conformance with the OBCprior to the issuance of any partial or conditional plan approval. TAOFFICEMMDOMDOC\Carection Request 2003\03-200950 Hilliards Fumiture doc HILLIARDS FURNITURE, Joseph P. Borghese, Jack D. Walters & Assoc., Inc., Application No. 03-200950 July 18, 2003 Page 2 of 3 Item 1. The addition, plus the existing space west of the fire wall, is 10,228 square feet. The base allowance from Table 503 is 9,000 sq. ft?one story. The bulling is open for firefighting on the south and west sides, so the additional 25% allowance permits this "building" to be 1.25 x 9,000 =11,250 sq. ft., which is greater than the 10,228 actual square footage. Item 2. Coordinate the location of the notifiersignals for the smoke detectors with the Building and Fire Inspectors. o Item 3. The double doors on the east side of the building are to remain unblocked during business hours when customers are in the mercantile space. Item 4. The owner is to provide an affidavit of flame spread and smoke contributed for the carpet, to the Field Inspector, before it is installed. Item 5. NEC 250-116. Nonelectric Equipment. The metal parts of non-electric equipment described in this section shall be grounded. (1) Frames and tracks of electrically operated cranes and hoists (2) Frames of nonelectrically driven elevator cars to which electric conductors are attached (3) Hand-operated metal shifting ropes or cables of electric elevators FPN: Where extensive metal in or on buildings may become energized and is subject to personal contact, adequate bonding and grounding will provide additional safety. Item 6. Provide the following electrical information: (1) Provide available fault current to show that the existing 200 a service is properly protected (2) Provide load calculations to show that the existing 200 a panel is not overloaded. (3) Connected load of the new 200 a disconnect exceeds 80% of it's capacity (160 amp maximum permitted load). (4) Identify conductor type. (5) Identify wiring method and material. (6) Provide wireway size. (7) All ground rods must be bonded together. (8) Provide voltage drop calculations (ASHRAE is 2% maximum). > 7 1-2+1o5 T:\OFFICE\WP\DOCS\DOC\Cc re ion Request 2003\03-2009 0 Hilli.,& Fumiture doc HILLIARDS FURNITURE, Joseph P. Borghese, Jack D. Walters & Assoc., Inc., Application No. 03-200950 July 18, 2003 Page 3 of 3 This review does not preclude the necessity to conform with provisions which may have been omitted or overlooked in the review process, but which are requirements of the code. Ultimate responsibility for legal compliance with the Standards of Safety rest with the registered design professional, the tenant and the owner. This review is based upon the information contained within the submitted drawings and related documents. Once corrections are made, submit four (4) complete sets of plans to the City of Dublin, Division of Building Standards. TO REQUEST AN APPEAL HEARING, YOU MUST sent a written request, listing the items to be appealed and the relief sought and a copy of this order to: Robert Price, Chief Building Official City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 Reviewed and Signed, M in F. Strayer, Robert Price ommercial Plans x ner Chief Building Official 4~~ / 8/0 D3 Si6atugf - Archite , Engineer or Contractor Dat (Optional) o s e~ P Qo r e. s e., Ar-cAJCZ~ 074 ( off Print Name and Title as Signed T:\OFFICE\WP\DOCS\DOC\Carecticn Request 2003\03-200950 Hilliards Furniture.doc CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Q V ffiy 11 SUBCONTRACTOR ° ' is et DISCLOSURE Xneral ip AlfI ~ o~ Cok ractor: : C e. ask I I-e..'c Application No.: Ob - a 0DC1 Job Address: b The General Contractor is required to furnish the following information regarding any contractor working at the above address prior to issuance of a Certificate of Occupancy. All subcontractor registrations must be current through the issuance of a Certificate of Occupancy, including insurance and all applicable State Certifications. TYPE NAME OF CONTRACTOR DUBLIN REGISTRATION NO. EXCAVATION* ' I k, c- / 3j CONCRETE* C il t _Q. J` r _ y9 MASONRY ~ ~ la5 r coop STRUCTURAL* ELECTRICAL* c S ELec i ry eupl f PLUMBING* 2 + e FF --s NX<< L r3 HVAC* INSULATION T V7 ROOFING* No,( t, - a: Sac 01/- DRYWALL = r SIDINGS r~ o~ re 1 fi~on SANITARY SEWER* l/~s so 041- LANDSCAPING !r So 5 I'~ J - FIRE PROTECTION UNDERGROUND Al 1A FIRE ALARM /U A FIRE SUPPRESSION Aj /)I PAINTING ;"rr-exs P ca, LA ; D prior r iS orJ OTHER `MUST BE COMPLETED AND AVAILABLE AT TIME OF FRAMING INSPECTION AND A COPY AVAILABLE FOR THE INSPECTOR TO TAKE TO OFFICE. Excel/Subcontractor Disclosure Update 2003 JACK D. WALTERS & ASSOCIATES, INC. P. 0. BOX 855 5166 BLAZER MEMORIAL PARKWAY DUBLIN, OHIO DUBLIN, OHIO 43017 ARCHITECTS ENGINEERS April 5, 2004 Hochstetler Buildings, Inc. 7929 Memorial Drive Plain City, Ohio 43064 Re: Hilliards Furniture Company, Retail Addition 6419 Old Avery Road, Dublin, Ohio JDW Job No: 011-01.1, Dublin Per #03-2 00950 Attn: Phil Hochstetler: At your request, I reviewed the project documents regarding the securement of the LVL support beam for the trusses over the lower roofed "porch" area. There is a discrepancy on the approved documents: on the Framing plan B/S2 the anchorage for the 1-3/4"X11-7/8" LVL beam is listed as min. (6) 7 ga. ring shank nails per column location, while on the Wall Section C/A3 the anchorage is listed as (6) 3/8" x 5" lag screws at each column location. After reviewing the design values for the ring shank nails, we have determined that they are sufficient to support the anticipated loading, and are approved for use in this application. Feel free to contact this office if you have any questions or require additional information regarding this matter. Sincerely; OF 4 ~ P~E co ~/o Joseph P. Borghese, Arc itect f` •''•s, Jack D. Walters & Assoc., Inc * JOSEPH S' P. Enclosure: _ = BORGHESE 1. Estimated shear values, ring shank nails. 3 10741 ` ~y s). &ED ARG~ M 614/889-2516 FAX 614/889-5596 i JUN-26-2003 16:23 FROM:HOGE LUMEER 4197532963 TO:HOCHSTETLER P:1/1 45:48109 13:43 FAX 813 213 7aaa WE NAIL ~ QO7.1o01 ESTIMATED SHEAR VALUES - ;--mooch Shank Nails GAUGE OF NAJL Wit. F 334 433 522 Sf7 617 799 4it Os2 t14+F *.4*01771 9535 ZZ34 '1836 7754 7348 . . 451 592 1?t5 103 913 1041 1171 13o3 1369 1674 223! 3042 1010 4467 1000 Qu*wmw 1 1D1 131 ibt 178 202 231 282 288 314 113 4J?S 471 9f$ 9f9 2223 '0aw 11a 142 172 1113 219 MR 281 313 376 4S1 531 739 604 1074 2616 01002 ,tti 164 1111 268 237 272 004 SS4 4DG 487 381 735 SU 1160 2109 154 is l 234 293 21111 $a 342 343 i7L 412 eta 732 1001 821 1480 32a6 P>r304 r 211 273 336 311 421 A 604 60f tza aye 1030 1413 1150 2062 4134 ESTIMATED SHEAR VALUES inng Shank Nails GAUGG OF NIML arm rc, i a ; 257 346 417 464 333 "2 sa4 761 Sitd 1084 X308 1789 1484 25 Q0 S>172 x63 473 572 642 700 236 936 1042 1282 1300 179D 2448 ,TAO! 3571 pact 81 100 120 142 jai 185 207 230 v7 332 391 " trA~'!if '241 444 790 1778 811 111 107 114 121 209 233 250 301 331 430 6111 C~ 487 dSS 7833 1!1111 102 217 2A 2'70 329 316 444 126 121 927 ZOa7 ~ • cCit~as 12 123 149 20 1S+t 1117 210 230 271 ' .STAt 308 341 409 490 SU 800 6EC 11ST 2699 7"c 344 169 218 ?64 227 377 38$ 432 440 1178 6117 s2fi 9130 1027 tads 3711. E5TUAATED SHEAR'VALUF-S rrai Shank Nails gfi~ "UGE OF NAL Type 14`41,' .~ttti3[,* a a~ ~ 4' Jul 390 470 St9 101 689 771 dSd 1031 12]6 1+174 ?017 ta35 2542 6610 412 534 64 823 4~3 1056 1174 1491 1691 2011 2759 22f5 4OZd 9046 rt t1! 141 144 tag 209 233 250 Sit 374 411 610 8D1 880 2000 9! 129 1Sa 171 497 227 717 2*2 401 485 ee3 044 !a0 Z1 t4 107 139 188 187 214 243 274 711.4 aa5 439 621 716 &as 1045 2210 CJtQ1 ,3~ 1r4 211 237 tag aaa 315 a'7'J~.ESS 384 4141 662 a8D 9G2 740 1311 2457 ,DO 248 ~r 774 779 433 417 S2Z 1152 780 931 1273 10dS 1858 4175 I 1 CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 APPLICATION FOR HVAC PERMIT v~ a Date ® ~ Application No. ©~j ` - POD " 5 D Job Address 4e0e,*/ . / ® A~~44 4t;~' Parcel No. Subdivision ,,L Lot No. Owner Name ~f A~Xli 1 k `L Telephone Contractor Name ~ 'g / ( $p A je//~ 70 Telephone Ae K 7 ,?f- Contractor Address ? r Dublin Registration No. 0 73 ~31C~ Residential: Sq. Ft. $30.00 Minimum plus $20.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. (Replacement units, minimum fee) Commercial: New/Addition Sq. Ft. Alteration New/Addition: $30.00 Minimum plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Alteration: $30.00 Minimum plus $10.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. 3% State of Ohio Surcharge (commercial only) Total $ U.. `p JOB DESCRIPTION This permit is granted on the express condition that the said work shall in all respects, conform to the ordinances of the City of Dublin and all the laws of the State regulating construction, installation, repair and alteration, and may be revoked at any time upon violation of any provisions of said laws. Signature of licensed contractor or homeowner lop, Division of Building Standards t Application Number . . . . . 03-00200950 Date 4/02/04 Revision number . . . . . . . 5 Pin number . . . . . . .580650 Property Address . . . . . . 6419 OLD AVERY RD Parcel Number . . . . . . . . 273-000303 Alternate Address . . . . . . HILLIARDS FURNITURE Tenant nbr, name . . . . . . HILLIARD FURNITURE Application description . . . COM BUILDING ADDITION Property owner . . . . . . . MCKITRICK JAMES R Contractor . . . . . . . . . HOCHSTETLER BUILDINGS, INC. Structure Information Construction Type . . . . . 5B - UNPROTECTED COMB Occupancy Type . . . . . . MERCANTILE Permit . . . . . . COM HEATING, VENTILATING, A.C. Additional desc . . Permit Fee . . . . 230.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 30.00 10.00 20.0000 THOU COM HVAC NEW/ADD 200.00 Special Notes and Comments SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 MAINTAIN/INSTALL PROTECTIVE TREE FENCING DURING ALL PHASES OF CONSTRUCTION SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 MAINTAIN/INSTALL PROTECTIVE TREE FENCING DURING ALL PHASES OF CONSTRUCTION APPROVAL FOR CONSTRUCTION OF MAJOR BUILDING AND SITE EXPANSION OF EXISTING FURNITURE STORE. SEE RECORDS OF ACTION #03-023DP (DATED 4/17/03) AND #02-007Z (DATED 4/11/02) FOR ADDITIONAL CONDITIONS OF APPROVAL. SEE NOTES ON PERMIT SETS. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 TREES SIX INCHES IN CALIPER OR GREATER AT DBH MUST BE PROTECTED PRIOR TO AND DURING ALL PHASES OF CONSTRUCTION - INCLUDING GRADING ACTIVITIES. PROTECT LANDSCAPING AS PER DUBLIN'S LANDSCAPE INSPECTOR AT fr w Page 2 Application Number . . . . . 03-00200950 Date 4/02/04 Revision number . . . . . . . 5 Pin number . . . . . . .580650 Special Notes and Comments (614) 410-4660. MAINTAIN/INSTALL PROTECTIVE TREE FENCING DURING ALL PHASES OF CONSTRUCTION Other Fees . . . . . . . . . COM BLDG INSPECT NEW/ADD 760.00 COM CERTIFICATE OF OCC 120.00 SURCHARGE FEE - ELECTRIC 26.70 SURCHARGE FEE - BLDG 45.90 SURCHARGE FEE - HVAC 6.90 Fee summary Charged Paid Credited Due Permit Fee Total 230.00 .00 .00 230.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 959.50 952.60 .00 6.90 Grand Total 1189.50 952.60 .00 236.90 CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 462-3865 (Franklin County) Date d Application No. 03 -AQ0q 5D ? New ? Remodel Residential Commercial APPLICATION FOR PLUMBING PERMIT The undersigned hereby applies for a permit to do plumbing and an inspection of same at the following location in accord with Chapter 4101:2-51 of the Ohio Administrative Code, and all regulations of the Franklin County Board of Health. Job Address L H l O l dl &+VMrte Parcel No. Subdivision/Project Names Grn.+:. 5-~-~?-~-~ Lot No Owner's Name Telephone Contractor's Name Telephone(P r `4 g L4-10 Contractor's Address Debiir? Registration Number Does the sewer discharge into an individual sewage diiis;)osal system o anitary sews How far distant from any dwelling, well or cistern is the sewage tank? What is the size of the main drain? 4 it Of what matefts do the vent pipes consist? SGb~ d d lOvG Of what material does the house drain consist? <C'n 4- r if Ct "INDICATE NAME OF CERTIFIED BACKFLOW TESTER INSTRUCTIONS This form must be properly filled out and returned to the office of the City of Dublin at least four days prior to the date of the FIRST INSPECTION, accompanied by a fee calculated upon the following basis: RESIDENTIAL COMMERCIAL Application for permit & first fixture $50.00 Application for permit & first fixture $60.00 Number of remaining fixtures X $10.00 = $ k _ Number of remaining fixtures X $12.00 = $ 1.2---d"0 Total Inspection Fee $ Total Inspection Fee $131-Q3 Re-inspection fee (based upon disapproved Inspection and collected by the Franklin County Board Of Health ONLY) $45.00 Qty. Qty. Qty. Air Admittance valve Garbage Disposal Showers "Backflow Preventers Hot Water Heater Sterilizers Bath Tubs Interceptor Sump Pump Bed Pan Washers Kitchen Sink Trap Primer Bidet Laundry Trays Urinal Chemical Sinks Lavatories Wash Fountain Dental Cuspidors Mop Sinks Washing Machine Dilution Sump Outside Faucets Water Closets Dish Washers Roof Drains Water Lines Drinking Fountain Rough-in Openings for Future Water Storage Tank Floor Drains Sewage Ejectors Other Garage Catch Basin GRAND TOTAL HOT WATER TANK REPLACEMENT FEE $35.00 Division of Building Standards IJM 03/11/2004 12:32 6144623851 FRANKLIN CO HEALTH PAGE 01/02 03/05/2004 14:12 6144623551 FRANKLIN CO HEALTH PAGE 01/01 Franklin County Board of Health ° PLUMBING REVIEW TRANSMITTAL Plan Review Fee Schedule Number of Fixtures: (11) Amount Due: $35.00 1- 5 tixtures $ 25.00 6 - 20 Fixtures $ 35.00 21-4 ' b Fixtures $ 65.00 0 3 _ 2 d C)g~V 41 or ore Fixtures $100.00 Date: March 91 2004 NEW REMODEL Job Name: Retail Addition to Hil,liard's Furniture Address:. 6419 Old Avery Road City: Dublin Ohio 43016 Signehire" Jack D. Walters and Associates, Inc., Architects & Engineers Plans Submitted by: Joseph P. Borghese, Project Architect Address: 5166 Blazer Parkway i City & Zip Dublin OH 43017 Phone* 614/889-2516 Fax # 614/889-5596 Paid 8y: APPROVED Check E3 DISAPPROVED Copy Td: Inspector: Date: Franklin County Board of Health 4 280 East Broad Street Columbus, ON 43215 (614) 462.3160 phone (614) 462-3951 fax i . 011-01 CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 Application Number . . . . . 03-00200950 Date 3/12/04 Revision number . . . . . . . 5 Pin number . . . . . . .580650 Property Address . . . . . . 6419 OLD AVERY RD Parcel Number . . . . . . . . 273-000303 Alternate Address . . . . . . HILLIARDS FURNITURE Tenant nbr, name . . . . . . HILLIARD FURNITURE Application description . . . COM BUILDING ADDITION Property owner . . . . . . . MCKITRICK JAMES R Contractor . . . . . . . . . HOCHSTETLER BUILDINGS, INC. Structure Information Construction Type . . 5B - UNPROTECTED COMB Occupancy Type . . . . . . MERCANTILE Permit . . . . . . PLUMBING PERMIT Additional desc . Permit Fee . . . . 132.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 60.00 6.00 12.0000 EA COM PLUMBING >1 FIXTURE 72.00 Special Notes and Comments SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 MAINTAIN/INSTALL PROTECTIVE TREE FENCING DURING ALL PHASES OF CONSTRUCTION SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 MAINTAIN/INSTALL PROTECTIVE TREE FENCING DURING ALL PHASES OF CONSTRUCTION APPROVAL FOR CONSTRUCTION OF MAJOR BUILDING AND SITE EXPANSION OF EXISTING FURNITURE STORE. SEE RECORDS OF ACTION #03-023DP (DATED 4/17/03) AND #02-007Z (DATED 4/11/02) FOR ADDITIONAL CONDITIONS OF APPROVAL. SEE NOTES ON PERMIT SETS. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 TREES SIX INCHES IN CALIPER OR GREATER AT DBH MUST BE PROTECTED PRIOR TO AND DURING ALL PHASES OF CONSTRUCTION - INCLUDING GRADING ACTIVITIES. PROTECT LANDSCAPING AS PER DUBLIN'S LANDSCAPE INSPECTOR AT This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. CITY OF DUBLIN Division of Building Standards - 5800 Shier-Rings Road - Dublin, Ohio 43016 Phone: (614) 410-4670 - Inspection Line: (614) 410-4680 Page 2 Application Number . . . . . 03-00200950 Date 3/12/04 Revision number . . . . . . . 5 Pin number . . . . . . .580650 Special Notes and Comments (614) 410-4660. MAINTAIN/INSTALL PROTECTIVE TREE FENCING DURING ALL PHASES OF CONSTRUCTION Fee summary Charged Paid Credited Due Permit Fee Total 132.00 .00 .00 132.00 Plan Check Total .00 .00 .00 .00 Grand Total 132.00 .00 .00 132.00 This permit is granted on the express condition that said work shall in all respects, conform to the ordinances of the City of Dublin and all laws of the State of Ohio regulating construction, installation, repair and alteration and may be revoked at any time upon violation of any provisions of law. - CITY OF DUBLIN Division of Building Standards • 5800 Shier-Rings Road • Dublin, Ohio 43016 Phone: (614) 410-4670 • Inspection Line: (614) 410-4680 0_ Application No. D3 - ,~-)bd 95n Date APPLICATION FOR ELECTRICAL PERMIT Job Address k Ll I Y 6W 9& ~ Parcel No. Subdivision 1 Lot No. Owner Name- 14 ~ Telephone ~ . !P teKf/ Telephone d - 31 't /3 Gu~--~-~~ `j. Contractor Named ~r~ o Contractor Address 6; ok 27 16 Dublin Registration No. - 6~ Residential: New Sq. Ft. Alteration/Addition Sq. Ft. OD Temporary Service c~O ~ of $60'WMinimum plus $20.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Low Voltage Systems: Square Feet $30.00 Minimum plus $10.00 for each additional 500 Sq. Ft. or fraction thereof over 1000 Sq. Ft. Commercial: Alteration/Addition Sq. Ft. New Sq. Ft. Temporary Service $60.00 $60.00 Minimum plus $60.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft. and up to 50,999 Sq. Ft. (sizes above, See Fee Schedule) Low Voltage Systems: Square Feet $30.00 Minimum (plus $20.00 for each additional 1000 Sq. Ft. or fraction thereof over 1000 Sq. Ft.) 3% State of Ohio Surcharge (commercial or" T JOB DESCRIPTION G 4,& io This permit is granted on the express condition that the said work shall in all respects, conform to t' Dublin, all the laws of the State and the National Electric Code regulating construction, instal' and may be revoked at any time upon violation of any provisions of said laws. c Wr Signature of licensed contractor or homeowner Division of Building Standards Application Number . . . . . 03-00200950 Date 3/08/04 Revision number . . . . . . . 5 Pin number . . . . . . .580650 Property Address . . . . . . 6419 OLD AVERY RD Parcel Number . . . . . . . . 273-000303 Alternate Address . . . . . . HILLIARDS FURNITURE Tenant nbr, name . . . . . . HILLIARD FURNITURE Application description . . . COM BUILDING ADDITION Property owner . . . . . . . MCKITRICK JAMES R Contractor . . . . . . . . . HOCHSTETLER BUILDINGS, INC. Structure Information Construction Type . . . . . 5B - UNPROTECTED COMB Occupancy Type . . . . . . MERCANTILE Permit . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 660.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 60.00 10.00 60.0000 THOU COM ELECTRIC SERVICE 1K-50K SF 600.00 Special Notes and Comments SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 MAINTAIN/INSTALL PROTECTIVE TREE FENCING DURING ALL PHASES OF CONSTRUCTION SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 MAINTAIN/INSTALL PROTECTIVE TREE FENCING DURING ALL PHASES OF CONSTRUCTION APPROVAL FOR CONSTRUCTION OF MAJOR BUILDING AND SITE EXPANSION OF EXISTING FURNITURE STORE. SEE RECORDS OF ACTION #03-023DP (DATED 4/17/03) AND #02-007Z (DATED 4/11/02) FOR ADDITIONAL CONDITIONS OF APPROVAL. SEE NOTES ON PERMIT SETS. SCREEN ALL MECHANICAL UNITS & SERVICE STRUCTURES TO TOP OF UNIT INCLUDING UTILITY FEATURES AND ROOF TOP MOUNTED EQUIPMENT. CONTACT PLANNING DIVISION 410-4600 TREES SIX INCHES IN CALIPER OR GREATER AT DBH MUST BE PROTECTED PRIOR TO AND DURING ALL PHASES OF CONSTRUCTION - INCLUDING GRADING ACTIVITIES. PROTECT LANDSCAPING AS PER DUBLIN'S LANDSCAPE INSPECTOR AT Page 2 Application Number . . . . . 03-00200950 Date 3/08/04 Revision number . . . . . . . 5 Pin number . . . . . . .580650 Special Notes and Comments (614) 410-4660. MAINTAIN/INSTALL PROTECTIVE TREE FENCING DURING ALL PHASES OF CONSTRUCTION Other Fees . . . . . . . . . SURCHARGE FEE - ELECTRIC 26.70 Fee summary Charged Paid Credited Due Permit Fee Total 660.00 .00 .00 660.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 26.70 6.90 .00 19.80 Grand Total 686.70 6.90 .00 679.80 e r, ~%NTIE30F WASHINGTON TOWNSHIP iU1{ FIRE DEPARTMENT ~ o= 6279 Shier Rings Road 'FhANK~~N Dublin, Ohio 43016-1294 614-889-2347 • Fax 614-766-2507 DATE: May 29, 2004 TO: Bob Price, CBO Division of Building Standards City of Dublin 5800 Shier Rings Road Dublin, Ohio 43016 ATTN: Martin Strayer, Commercial Plan Reviewer RE: Washington Township's Fire Department Plan Review PERMIT 03-200950(6) PROJECT: Billiards Furniture Retail Addition LOCATION: 6419 Old Avery Road RECEIVED: May 17 2004 Mr. Strayer: We have reviewed the drawing for the referenced project dated 5/09/03, revised 5/14/04 submitted to the Division of Building Standards May 17 04, for matters of concern to the Washington Township Fire Department regarding rules of the 2002 Ohio Building Code relating to fire prevention and the Dublin Fire Code(DFC) based upon the 2000 International Fire Code. We are able to recommend approval of the drawing as submitted.. Thank you for the opportunity to review the submission. Please feel free to call with any questions. WASHINGTON TO SHIP FIRE DEPARTMENT Ray M. Harpham, Architect/Plans Examiner Captain Alan Perkins Fire Prevention (614) 488-4009 Division Commander 614-798-2200 ext102 MAN= Reviews\Wa*m" Township\Reviews 03-04\03-200950(6) a CBO.wpd Trustees: Michael H. Keenan • Denise King • Ruth M. Reiss Clerk/Treasurer: Joyce E. Robinson Administrator: Tom Spring Chief: Allan Woo